Text of Quantum Scalar i500 Instructions Manual
Document 6-01894-02 October 2008
Scalar i500 Advanced Reporting
Instructions
Advanced Reporting Features
3
Required Firmware
3
Installing and Using Your Advanced Reporting License
3
Using the Reports and Understanding the Data
4
Loading and Reloading Advanced Reporting Data ................................................................4
Configuring the Drive Resource Utilization Report
5
Configuring the Media Integrity Analysis Report
6
Saving and E-mail
Scalar i500 Advanced Reporting Instructions
Document 6-01894-02
October 2008
2
Made in the USA.
Quantum Corporation provides this publication “as is” without warranty of any kind, either express or implied, including but not limited to the implied
warranties of merchantability or fitness for a particular purpose. Quantum Corporation may revise this publication from time to time without notice.
COPYRIGHT STATEMENT
© Copyright 2008 by Quantum Corporatio
Scalar i500 Advanced Reporting Instructions Document 6-01894-02
October 2008
Advanced Reporting Features
3
Advanced Reporting Features
0
Advanced Reporting provides the following reports that you can configure for viewing
and analysis:
•
Drive Resource Utilization Report — Provides tape drive usage information, showing
you which tape drives are working at optimum capacity and which are under-
utilized. This can help you allocate your tape drive resourc
Scalar i500 Advanced Reporting Instructions Document 6-01894-02
October 2008
4
Using the Reports and Understanding the Data
Using the Reports and Understanding the Data
0
Report data is collected and displayed in a specific manner. The following notes will help
you interpret the reports.
•
The data for these reports is collected in log files. When the log files reach their
maximum size, the oldest information is deleted as new information is added. This
Scalar i500 Advanced Reporting Instructions Document 6-01894-02
October 2008
Configuring the Drive Resource Utilization Report
5
Configuring the Drive Resource Utilization Report
0
1 From the library menu bar, select Reports > Advanced Reporting > Drive Resource
Utilization.
The Drive Resource Utilization Report configuration page opens. This may take
several minutes.
2 Configure the report by specifying the following:
•
Range — Specifies the range of
Scalar i500 Advanced Reporting Instructions Document 6-01894-02
October 2008
6
Configuring the Media Integrity Analysis Report
•
Selected Drive by Physical SN — The report chart is based on an individual
tape drive identified by its physical drive serial number.
•
Selected Partition — The report chart is based on an individual partition in
the physical library.
3 Click Next.
The report is generated and appears on the screen.
Configuring the Media I
Scalar i500 Advanced Reporting Instructions Document 6-01894-02
October 2008
Saving and E-mailing Advanced Reporting Data
7
•
Selected Cartridge by Barcode — An individual tape cartridge. Only tape
cartridges that were associated with a TapeAlert during the specified range
appear in the report.
•
Sorting — Specifies how the data will be sorted. Choose Alphabetical, Count, or
Last Occurrence (default).
3 Click Next.
The report is generated and appea
Scalar i500 Advanced Reporting Instructions Document 6-01894-02
October 2008
8
Deleting Advanced Reporting Data
Deleting Advanced Reporting Data
0
In some circumstances, you may wish to delete the data contained in the library log files
used to build the advanced reports. To do this, click the Delete button in the Report Data
section of either report configuration page. This deletes the data for both the Drive
Resource Utilization report and the Media Inte