Radio Shack Extra remote sensor Owner's Manual

Specifications

Brand: Radio Shack
Category: Remote Control
Model: Extra remote sensor (Owner's Manual)
File Type: PDF
File Size: 0.45 Mb
Pages: 20

Read Online

Read the Radio Shack Extra remote sensor Owner's Manual online using the built-in PDF viewer.

Text of the manual

Introduction ........................................ 4

Installing Batteries ............................ 5 Mounting the Sensor ........................ 8 Selecting a Location .................... 8 Using the Stand ........................... 9 On a Wall ................................... 10 Operation .......................................... 13 Changing the Display Channel ...... 13 Changing the Degree Format ........ 15 Resetting the Sensor ..................... 15 Care ................................................... 17 Specifications ................................... 18 © 2000 RadioShack Corporation. All Rights Reserved. RadioShack and RadioShack.com are trademarks used by RadioShack Corporation.

This device complies with Part 15 of the

FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interfer- ence received, including interference that may cause undesired operation. This equipment complies with the limits for a Class B digital device as specified in Part 15 of FCC Rules. These limits pro- vide reasonable protection against radio and TV interference in a residential area. However, your equipment might cause TV or radio interference even when it is operating properly. To eliminate interfer- ence, you can try one or more of the fol- lowing corrective measures:

• reorient or relocate the receiving

antenna • increase the distance between the equipment and the radio or TV Consult your local RadioShack store if the problem still exists. ˆ Introduction Your RadioShack Extra Remote Sensor is designed for use with the RadioShack Wireless Indoor/Outdoor Thermometer with Indoor/Outdoor Hygrometer system (Cat. No. 63-1030). Installation is easy, with no wires to connect. You can mount the remote sensor outdoors or in another room (away from the system’s main unit),

or use its supplied wire stand for easy

viewing on a table or desktop. INSTALLING BATTERIES Your sensor requires two AA batteries (not supplied) for power. For the best per- formance and longest life, we recom- mend RadioShack alkaline batteries. Cautions: • Use only fresh batteries of the required size and recommended type. • Do not mix old and new batteries, different types of batteries (standard, alkaline, or rechargeable), or rechargeable batteries of different capacities.

Note: If you expect to use the remote

sensor in temperatures below –4°F (–20°C), we recommend you use lithium batteries. Follow these steps to install batteries. 1. Use a Phillips screwdriver to remove the screws in the battery compart- ment cover, then lift off the cover. 2. Set CHANNEL and °C/°F inside the compartment to the desired set-

tings. (See “Changing the Display

Channel” on Page 13 and “Changing the Degree Format” on Page 15) 3. Place the batteries in the compart- ment as indicated by the polarity symbols (+ and –) marked inside. 4. Use a pointed object (such as a straightened paper clip) to press RESET and initialize the sensor’s transmitter. 5. Replace the cover and secure it with its screws. When appears (on either the sensor or under the sensor’s channel number on the main unit) or the sensor stops operat- ing properly, replace the batteries.

promptly and properly. Do not burn or

bury them. Caution: If you do not plan to use the sensor for a week or longer, remove the batteries. Batteries can leak chemicals that can destroy electronic parts. MOUNTING THE SENSOR You can place the remote sensor on a flat surface, or mount it on the wall using screws (not supplied) and the supplied bracket. Selecting a Location Choose a location for the remote sensor that is within about 328 feet (100 m) of the main unit. The remote sensor can be placed either indoors or out.

The construction of your home or office

might affect the transmission range be- tween the main unit and the remote sen- sor. If you have a choice of several locations, try each to see which provides the best performance. Caution: Do not place the remote sensor where it will be: • in direct sunlight • in water (it is weather-resistant, not water-proof) • near electrical appliances or heating or air conditioning vents Using the Stand To set the remote sensor on a flat sur- face, insert the ends of the supplied wire

stand into the holes on the back of the re-

mote sensor. On a Wall 1. Drill two holes 13/4 inches apart. Then thread a screw into each hole, letting the heads extend about 1/4 inch from the mounting surface.

2. Align the keyhole slots on the mount-

ing bracket with the screws and slide the bracket downward to secure it.

Once you install batteries in the remote

sensor, it displays the current tempera- ture, humidity, and the channel number it is set to, and starts transmitting signals (to your Cat. No. 63-1030 system’s main unit) about every 41 seconds. CHANGING THE DISPLAY CHANNEL The Cat. No. 63-1030 system’s main unit can display information for up to three dif- ferent remote sensors.

Set CHANNEL 1/2/3 inside this remote

sensor’s battery compartment to a differ- ent setting than all other remote sensors you are using. Then press RESET using a pointed object (such as a straightened paper clip). Note: If you set two or more remote sen- sors to use the same channel, the main unit displays temperature and humidity information for the remote sensor's signal it received first.

CHANGING THE DEGREE

FORMAT To change the displayed degree format, set °C/°F inside the remote sensor’s bat- tery compartment to the desired setting. RESETTING THE SENSOR If the remote sensor stops operating properly, use a pointed object (such as a straightened paper clip) to press RESET. This resets the displayed temperature

Keep the sensor dry; if it gets wet, wipe it

dry immediately. Use and store the sen- sor only in normal temperature environ- ments. Handle the sensor carefully; do not drop it. Keep the sensor away from dust and dirt, and wipe it with a damp cloth occasionally to keep it looking new. Modifying or tampering with the sensor’s internal components can cause a mal- function and invalidate its warranty. If your sensor is not performing as it should, take it to your local RadioShack store for assistance.

Power ......................... 3V with 2 AA Batteries

Temperature Operating Range ... –4° to 140°F (–20° to 60°C) Relative Humidity Operating Range ..................... 25%–90% RH RF Transmission Frequency ........... 433 MHz RF Transmission Range ........... 328 ft at sight (100m at sight) Resolution ............................................. 0.2°F (0.1°C) Approximate Sampling Cycle ...... 41 Seconds Accuracy ...................... ±1.8° at 32° to 104° F (0° to 40°C) ±3.6° at –40° to 122° F (–40° to 50°C) ±5.4° at –58° to 158° F (–50° to 70° C)

Weight (without batteries) ..................... 2.8 oz

(80 g) Dimensions ......................... 41/8 × 23/4 × 7/8 in (105 × 70 × 21.5 mm) Specifications are typical; individual units might vary. Specifications are subject to change and improvement without notice.

Printed in China

Limited One-Year Warranty This product is warranted by RadioShack against manufacturing defects in material and workmanship under normal use for one (1) year from the date of purchase from Ra- dioShack company-owned stores and authorized RadioShack franchisees and dealers. EXCEPT AS PROVIDED HEREIN, RadioShack MAKES NO EXPRESS WARRANTIES AND ANY IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE DU- RATION OF THE WRITTEN LIMITED WARRANTIES CONTAINED HEREIN. EXCEPT AS PROVIDED HEREIN, RadioShack SHALL HAVE NO LIABILITY OR RESPONSIBIL- ITY TO CUSTOMER OR ANY OTHER PERSON OR ENTITY WITH RESPECT TO ANY LIABILITY, LOSS OR DAMAGE CAUSED DIRECTLY OR INDIRECTLY BY USE OR PERFORMANCE OF THE PRODUCT OR ARISING OUT OF ANY BREACH OF THIS WARRANTY, INCLUDING, BUT NOT LIMITED TO, ANY DAMAGES RESULTING FROM INCONVENIENCE, LOSS OF TIME, DATA, PROPERTY, REVENUE, OR PROFIT OR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAM- AGES, EVEN IF RadioShack HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Some states do not allow limitations on how long an implied warranty lasts or the exclu- sion or limitation of incidental or consequential damages, so the above limitations or ex- clusions may not apply to you. In the event of a product defect during the warranty period, take the product and the Ra- dioShack sales receipt as proof of purchase date to any RadioShack store. RadioShack will, at its option, unless otherwise provided by law: (a) correct the defect by product re- pair without charge for parts and labor; (b) replace the product with one of the same or similar design; or (c) refund the purchase price. All replaced parts and products, and products on which a refund is made, become the property of RadioShack. New or recon- ditioned parts and products may be used in the performance of warranty service. Re- paired or replaced parts and products are warranted for the remainder of the original warranty period. You will be charged for repair or replacement of the product made after the expiration of the warranty period. This warranty does not cover: (a) damage or failure caused by or attributable to acts of God, abuse, accident, misuse, improper or abnormal usage, failure to follow instructions, improper installation or maintenance, alteration, lightning or other incidence of excess voltage or current; (b) any repairs other than those provided by a RadioShack Authorized Service Facility; (c) consumables such as fuses or batteries; (d) cosmetic damage; (e) transportation, shipping or insurance costs; or (f) costs of product removal, installation, set-up service adjustment or reinstallation. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. RadioShack Customer Relations, 200 Taylor Street, 6th Floor, Fort Worth, TX 76102 We Service What We Sell 12/99

Other Remote Control Manuals