Sensormatic SpeedDome Optima Update Instructions
Read Online
Read the Sensormatic SpeedDome Optima Update Instructions online using the built-in PDF viewer.
Text of the manual
SpeedDome Ultra I/Ultra II Update Instructions
for View Manager 96 version 4.0/4.1
8000-1952-02, Rev. A (7 total pages)
SENSORVISION PRODUCTS
1
About this Kit
This kit provides update diskettes for SpeedDome
Ultra I and SpeedDome Ultra II domes installed
with VM96 version 4.0/4.1 running on SensorNet
networks only. Do not use these instructions
with SpeedDome Ultra I or Ultra II domes
installed on RS-422 networks.
This kit contains the following parts:
a) SpeedDome Ultra I Update Diskette
0701-2820-0101
b) SpeedDome Ultra II Update Diskette
0701-2821-0101
c) SDU I/II Update Instructions for VM96
8000-1952-02
Identifying Dome Types
Before you attempt to update any domes, you
must first identify the types of domes installed. If
the site does not have SpeedDome Ultra I or Ultra
II domes installed, you do not need to perform this
update.
To identify the types of domes installed, use the
VM96 Administrator menus. If you are not familiar
with using these menus, refer to the VM96 System
Administrator’s manual (PN 8000-0606-04).
1. Start the Administrator menus.
2. Move the cursor to Config, then select
Cameras. Press ENTER.
The Configure Cameras form displays.
3. Note the address and version of all
SpeedDome Ultra I and SpeedDome Ultra II
domes installed.
− Use the SpeedDome Ultra I/II Worksheet
provided on page 7 of this document.
− Make copies of this worksheet if necessary.
4. Search through each camera record to
determine which cameras are either
SpeedDome Ultra I or Ultra II.
− To do this, press Alt+S to start the search
menu.
− Use the arrow keys to select Next Form.
− Go through all forms noting the address and
version information associated with
SensorNet SpeedDome Ultra I and Ultra II
domes only
The following is an example of the Configure
Cameras form for SpeedDome Ultra I. The last
four digits of the Camera Version will be 02XX
for SpeedDome Ultra I.
Configure Cameras
Camera Number 1
Camera Name Camera 1
Camera Type SensorNet SpeedDome Ultra
Serial Number 1
Camera Address 1
Camera Version 070123150204
EE Version 070199800102
The following is an example of the Configure
Cameras form for SpeedDome Ultra II. The last
four digits of the Camera Version will be 03XX
for SpeedDome Ultra II.
Configure Cameras
Camera Number 1
Camera Name Camera 1
Camera Type SensorNet SpeedDome Ultra
Serial Number 1
Camera Address 1
Camera Version 070123150301
EE Version 070199800105
After recording the information related to the
installed SpeedDome Ultra I and Ultra II domes,
you are ready to begin upgrading the domes.
Upgrade Procedure
If you have both SpeedDome Ultra I and Ultra II
domes that need to be upgraded, it is highly
recommended that you upgrade the Ultra I domes
first. By first upgrading the Ultra I domes, you can
use the quick method for updating SpeedDome
Ultra II domes described later in this document.
IMPORTANT PRECAUTIONS
Be sure that you use the correct diskette for the
type of domes you are upgrading. Using the wrong
files during the download process could render the
dome useless. USE CAUTION!
SPEEDDOME ULTRA I/II UPDATE INSTRUCTIONS
8000-1952-02, Rev. A
Upgrading SpeedDome
Ultra I Domes
If you do not have SpeedDome Ultra I domes to
update, continue with the section titled Updating
SpeedDome Ultra II Domes.
1. Insert the diskette labeled “SpeedDome
Ultra I Update Diskette” in the VM96 system
diskette drive.
2. Start the Administrator Menus.
a. Use the arrow keys to move the cursor to
Utilities, then select Copy File To/From
DOS
b. Press ENTER.
3. At the Source prompt, type a:/* then press
ENTER.
4. At the Directory prompt type . then press
ENTER.
5. At the Ascii/binary prompt, press ENTER.
6. As the files copy, the system prompts you
to overwrite existing files. Press Y, then
ENTER to overwrite the files.
− Each new message is always written on the
top line of the display. Watch these
messages carefully to ensure that you
answer each prompt.
− When all files are copied, the system
returns to the Utilities menu.
7. Change the file modes on the batch files.
a. With the Utilities menu displayed, select
Exec Utility.
b. Use the arrow keys to highlight the file
named /bin/chmod. Then press ENTER.
8. The Arguments prompt appears. Type the
following command:
a. 777 *.bat
b. Press ENTER
c. The system returns to the Utilities menu.
9. Move the cursor to Exec Utility. Press
ENTER.
10. Use the arrow keys to highlight the file
named gethex.bat, then press ENTER.
− This command copies files from the diskette
to the hard drive and removes bin files.
11. The Arguments prompt appears. Press
ENTER.
− Messages may appear on the screen.
− You may be prompted to overwrite files; if
so, press Y then ENTER.
− When the Message window appears, press
ESC twice to return to the Administrator
menu.
12. Remove the diskette from the VM96 system
diskette drive.
You are now ready to begin downloading
SpeedDome Ultra I domes. Refer to the section
titled Downloading Ultra I Domes.
Downloading Ultra I Domes
IMPORTANT PRECAUTIONS
Be sure that you know which type of domes you
are downloading. You cannot download both
SpeedDome Ultra I and SpeedDome Ultra II
domes using the same files. Using the wrong files
during the download process could render the
dome useless. USE CAUTION!
Note: If you experience failures while performing
this procedure, attempt the download again.
1. From the Administrator menu, select
Utilities, then Network Maintenance. Press
ENTER.
2. The list of devices displays. Use the arrow
keys to select SensorNet SpeedDome Ultra,
then press ENTER.
3. Use the arrow keys to move the highlight to
the Device Number field.
4. Referring to the worksheet, type the
address of the dome you are trying to
download in the Device Number field.
5. Use the down arrow key to move the cursor
to the Device Function field, then select
Force Download Flash. Press ENTER.
8000-1952-02, Rev. A
SPEEDDOME ULTRA I/II UPDATE INSTRUCTIONS 7
6. Press Alt+P, R, then ENTER to start the
download.
− You will be prompted to continue with the
download. Select Continue then ENTER.
− The download takes approximately 5
minutes. Repeat steps 3 through 6 for each
dome that needs to be downloaded.
Remember that you cannot download both
Ultra I and Ultra II domes during the same
session.
7. When finished downloading, press Alt+X,
then ENTER.
8. Verify that the domes have the correct
versions.
− Follow the instructions found in the section
titled Identifying Dome Types on page 1.
− After the update, SpeedDome Ultra I domes
will have a version of 0210.
− The EE version for both Ultra I and II domes
will be 070199800105.
9. After downloading all Ultra I domes, remove
the download files so that a user does not
inadvertently attempt to download domes.
a. Move the cursor to Utilities, then select
Exec Utility.
b. Use the arrow keys to highlight remhex.bat,
then press ENTER.
c. At the Arguments prompt, press ENTER.
d. When the message window appears, press
ESC twice to return to the Administrator
menu.
Upgrading SpeedDome
Ultra II Domes
If you have downloaded SpeedDome Ultra I
domes, you can use the Quick Update Method
for SpeedDome Ultra II on page 5. Otherwise,
follow these instructions to upgrade the domes.
1. Insert the diskette labeled “SpeedDome
Ultra II Update Diskette” in the VM96 system
diskette drive.
2. Start the Administrator Menus.
a. Use the arrow keys to move the cursor to
Utilities, then select Copy File To/From
DOS
b. Press ENTER.
3. At the Source prompt, type a:/* then press
ENTER.
4. At the Directory prompt type . then press
ENTER.
5. At the Ascii/binary prompt, press ENTER.
6. As the files copy, the system prompts you
to overwrite existing files. Press Y, then
ENTER to overwrite the files.
− Each new message is written on the top line
of the display. Watch these messages
carefully to ensure that you answer each
prompt.
− When all files are copied, the system
returns to the Utilities menu.
7. Change the file modes on the batch files.
a. With the Utilities menu displayed, select
Exec Utility.
b. Use the arrow keys to highlight the file
named /bin/chmod. Then press ENTER.
8. The Arguments prompt appears. Type the
following command:
a. 777 *.bat
b. Press ENTER.
c. The system returns to the Utilities menu.
9. Move the cursor to Exec Utility. Press
ENTER.
10. Use the arrow keys to highlight the file
named gethex.bat, then press ENTER.
− This command copies files from the diskette
to the hard drive and removes bin files.
11. The Arguments prompt appears. Press
ENTER.
− Messages may appear on the screen.
− You may be prompted to overwrite files; if
so, press Y then ENTER.
− When the Message window appears, press
ESC twice to return to the Administrator
menu.
12. Remove the diskette from the VM96 system
diskette drive.
SPEEDDOME ULTRA I/II UPDATE INSTRUCTIONS
8000-1952-02, Rev. A
You are now ready to begin downloading
SpeedDome Ultra II domes. Refer to the section
titled Downloading Ultra II Domes on page 4.
Downloading Ultra II Domes
Downloading SpeedDome Ultra II domes is a two-
phase process. Use these instructions for
SpeedDome Ultra II domes only.
IMPORTANT PRECAUTIONS
Be sure that you know which type of domes you
are downloading. You cannot download both
SpeedDome Ultra I and SpeedDome Ultra II
domes using the same files. Using the wrong files
during the download process could render the
dome useless. USE CAUTION!
Note: If you experience failures while performing
this procedure, attempt the download again.
Phase 1
1. From the Administrator menu, select
Utilities, then Network Maintenance. Press
ENTER.
2. The list of devices displays. Use the arrow
keys to select SensorNet SpeedDome Ultra,
then press ENTER.
3. Use the arrow keys to move the highlight to
the Device Number field.
4. Referring to the worksheet, type the
address of the dome you are trying to
download in the Device Number field.
5. Use the down arrow key to move the cursor
to the Device Function field, then select
Force Download Flash. Press ENTER.
6. Press Alt+P, R, then ENTER to start the
download.
− You will be prompted to continue with the
download. Select Continue then ENTER.
− The download takes approximately 5
minutes. Repeat steps 3 through 6 for each
dome that needs to be downloaded.
Remember that you cannot download both
Ultra I and Ultra II domes during the same
session.
7. When finished downloading, press Alt+X,
then ENTER.
8. Verify that the domes have the correct
versions.
− Follow the instructions found in the section
titled Identifying Dome Types on page 1.
− After the update, SpeedDome Ultra II
domes will have a version of 0306.
− The EE version for both Ultra I and II domes
will be 070199800105.
Phase 2
Perform this procedure only after completing
Phase 1. These steps must be performed for all
SpeedDome Ultra II domes.
1. From the Administrator menu, select
Utilities, then Exec Utilities. Press
ENTER.
2. Use the arrow keys to locate getcl.bat, then
press ENTER.
a. At the Arguments prompt, press ENTER.
b. When the Message Window appears,
press ESC twice to return to the
Administrator menu.
3. From the Administrator menu, select
Utilities, then Network Maintenance. Press
ENTER.
4. The list of devices displays. Use the arrow
keys to select SensorNet SpeedDome Ultra,
then press ENTER.
5. Use the arrow keys to move the highlight to
the Device Number field.
6. Referring to the worksheet, type the
address of the dome you are trying to
download in the Device Number field.
7. Use the down arrow key to move the cursor
to the Device Function field, then select
Force Download Flash. Press ENTER.
8. Press Alt+P, R, then ENTER to start the
download.
− You will be prompted to continue with the
download. Select Continue then ENTER.
8000-1952-02, Rev. A
SPEEDDOME ULTRA I/II UPDATE INSTRUCTIONS 7
− The download takes approximately 5
minutes. Repeat steps 5 through 8 for each
dome that needs to be downloaded.
Remember, you cannot download both Ultra
I and Ultra II domes during the same
session.
9. When finished downloading, press Alt+X,
then ENTER.
10. Verify that the domes have the correct
versions.
− Follow the instructions found in the section
titled Identifying Dome Types on page 1.
− After the update, SpeedDome Ultra I domes
will have a version of 0210; SpeedDome
Ultra II domes will have a version of 0306.
− The EE version for both Ultra I and II domes
will be 070199800105.
11. After downloading all Ultra II domes,
remove the download files so that a user
does not inadvertently attempt to download
domes.
a. Move the cursor to Utilities, then select
Exec Utility.
b. Use the arrow keys to highlight remhex.bat,
then press ENTER.
c. At the Arguments prompt, press ENTER.
d. When the message window appears, press
ESC twice to return to the Administrator
menu.
Note: Sometimes domes will stall during the
initialization process. If this happens, enter the
dome number then press Cam on the Touch
Tracker. Reset the dome by pressing 0, Menu, 3
on the Touch Tracker.
Quick Update Method for
SpeedDome Ultra II
Use this method if you have already downloaded
SpeedDome Ultra I domes.
1. Insert the diskette labeled “SpeedDome
Ultra II Update Diskette” in the VM96 system
diskette drive.
2. Use the arrow keys to move the cursor to
Utilities, then select Exec Utility. Press
ENTER.
3. Use the arrow keys to highlight the file
named gethex.bat, then press ENTER.
− This command copies files from the diskette
to the hard drive and removes bin files.
4. The Arguments prompt appears. Press
ENTER.
− Messages may appear on the screen.
− You may be prompted to overwrite files; if
so, press Y then ENTER.
− When the Message window appears, press
ESC twice to return to the Administrator
menu.
You are now ready to begin downloading
SpeedDome Ultra II domes. Refer to the section
titled Downloading Ultra II Domes on page 4.
SPEEDDOME ULTRA I/II UPDATE INSTRUCTIONS
8000-1952-02, Rev. A
Future Dome Downloads
Use this method if you need to update domes in
the future.
1. Start the Administrator menus.
2. Identify the domes that require updating.
Refer to Identifying Dome Types on page 1.
3. Insert the update diskette in the VM96
system diskette drive.
− Insert the SpeedDome Ultra I diskette if you
are downloading Ultra I domes.
− Insert the SpeedDome Ultra II diskette if you
are downloading Ultra II domes.
4. Use the arrow keys to move the cursor to
Utilities, then select Exec Utility. Press
ENTER.
5. Use the arrow keys to highlight the file
named gethex.bat, then press ENTER.
− This command copies files from the diskette
to the hard drive and removes bin files.
6. The Arguments prompt appears. Press
ENTER.
− Messages may appear on the screen.
− You may be prompted to overwrite files; if
so, press Y then ENTER.
− When the Message window appears, press
ESC twice to return to the Administrator
menu.
7. Remove the diskette from the VM96 system
diskette drive.
You are now ready to begin downloading
SpeedDome Ultra I or Ultra II domes.
If you are updating SpeedDome Ultra I domes,
refer to the section titled Downloading Ultra I
Domes on page 2.
If you are updating SpeedDome Ultra II domes,
refer to the section titled Downloading Ultra II
Domes on page 4.
Note – Protection Violation
If you forget to change the mode of the .bat files,
you will see the following message in the Message
window:
Protection Violation
Refer to step 7 on page 2 in the section titled
Upgrading SpeedDome Ultra I Domes. This step
provides instructions for how to change the batch
file mode.
8000-1952-02, Rev. A
SPEEDDOME ULTRA I/II UPDATE INSTRUCTIONS 7
2 SpeedDome Ultra I/II Worksheet
Use this worksheet to determine which domes at your facility require updating. Make copies of this worksheet
before you begin. Rows 2 and 3 provide examples for completing the form.
(1) Write the Camera Address in Column 1.
(2) Write the last four digits of the Camera Version in column 2. Note: The first two parts of the version
number are already completed.
(3) Compare the version number to columns 3 and 4. If the last four digits of the version number is 02XX, the
dome type is SpeedDome Ultra I. If the last four digits of the version number is 03XX, the dome type is
SpeedDome Ultra II.
(4) Place a check mark in the appropriate column.
Camera
Address
Camera
Version
SpeedDome Ultra I
(Version 02XX)
SpeedDome Ultra II
(Version 03XX)
Exampl e 1 - Addr ess 1
0701-2315-0204
Exampl e 2 – addr ess 2
0701-2315-0301
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-
0701-2315-