GE NX-1710E - Single Door Control Module Installation Manual
Text of the manual
NX-1710E Single Door Control
2
© 2005 GE Security
All rights reserved.
NetworX™ is a trademark of the GE companies. Printed in the USA.
These instructions do not purport to cover all details or variations in equipment nor to provide every
possible contingency to be met during installation, operation, and maintenance. If further information is
desired or if particular problems arise that are not covered sufficiently for the purchaser’s purpose, the
matter should be referred to GE Security, Gladewater, Texas, USA.
This document contains proprietary information of GE Security, USA and is furnished to its customer solely
to assist that customer in the installation, testing, operations, and/or maintenance of the equipment
described. This document shall not be reproduced in whole or in part nor shall its contents be disclosed to
any third party without the written approval of GE Security.
Please refer to the current GE Security product catalog for detailed warranty information.
Symbol Legend
Warning
Indicates a procedure, practice, condition, or statement that, if not strictly observed, could
result in personal injury.
* This symbol indicates electrical warnings and cautions.
Caution
Indicates a procedure, practice, condition, or statement that, if not strictly observed, could
result in damage to or destruction of equipment or property.
** This symbol indicates general warnings and cautions.
Note
Indicates an essential or important procedure, instruction, condition, or statement.
Tip
Indicates a user tip. Provides helpful information that is not normally defined in regular use,
but from an experienced user.
Enter
Indicates a key or button should be pressed to enter data.
NX-1710E Single Door Control
3
TABLE OF CONTENTS
I.
GENERAL DESCRIPTION.............................................................................................4
II.
BOARD LAYOUT...........................................................................................................5
III.
INSTALLATION AND WIRING TERMINALS ................................................................6
IV.
ENROLLING...................................................................................................................6
V.
ADDRESSING................................................................................................................7
VI.
PROGRAMMING............................................................................................................7
VII.
USER CARDS................................................................................................................9
VIII.
PROGRAMMING LOCATIONS ...................................................................................11
IX.
PROGRAMMING WORKSHEETS...............................................................................20
X.
ORDERING INFORMATION........................................................................................35
XI.
GLOSSARY..................................................................................................................35
XII.
FCC INFORMATION ....................................................................................................36
XIII.
UNDERWRITERS LABORATORIES INFORMATION ................................................36
XIV.
SPECIFICATIONS........................................................................................................36
Main
800-727-2339
Technical Support
800-727-2339
Outside the US
903-845-6941
Tech Support Fax
903-845-8409
Main Fax
903-845-6811
Sales & Literature
800-547-2556
Web: www.ge-security.com
NX-1710E Single Door Control
4
I.
GENERAL DESCRIPTION
The NetworX NX-1710E is a single door control module used to expand the capabilities of the NetworX control
panels.
•
Flash-based microprocessor for reprogramming ability via In-Circuit Serial Programming™ header
•
+5 VDC and +12 VDC outputs
•
4-position dip switch which allows addressing of up to 16 modules on the NetworX bus
•
Box tamper switch tied to tamper terminal
•
One zone input to be connected to a door contact for monitoring the door zone.
•
On-board relay with Normally Open, Normally Closed, and Common terminals for use in switching
power on MagLocks or other door locking mechanisms
•
8Kb of non-volatile RAM for storing programming and card data
•
Two sets of terminal inputs/outputs for interfacing with one or two Wiegand card readers:
o
1 buzzer and 2 LED outputs
o
1 tamper and 1 egress input
o
2-wire Wiegand bus interface. Readers must be able to “speak” Wiegand. The
following are supported Weigand formats by default:
26-bit standard Weigand
27-bit Tecom ASC
35-bit HID Corporate 1000
37-bit HID 10304
40-bit with facility code (Casi Rusco 4001)
40-bit without facility code (Casi Rusco 4002)
NX-1710E Single Door Control
5
II.
BOARD LAYOUT
NetworX bus
Programmer
Dip Switches
(see pg 7 for
specifics.)
LED is lit during
normal operation.
NX-1710E Single Door Control
6
III.
WIRING TERMINALS
To install the door control, simply wire it into the system. Refer to the following wiring table for details.
For the purpose of these instructions, the term “door control” refers to the NX-1710E module, and
the term “reader” refers to the specific card reader attached to the system.
IV.
ENROLLING
The NetworX control panels have the ability to automatically find and store in memory the presence of all
keypads, zone expanders, wireless receivers, output modules, and any other device on the keypad buss. This
allows these devices to be supervised by the control panel. To enroll the devices, enter the Program Mode
using the procedure outlined in the control panel Installation Manual. When the Program Mode is exited, the
NX-8 control will automatically enroll the devices. The enrolling process takes about 12 seconds, during which
time the Service LED will illuminate. User codes will not be accepted during the enrolling process. Once a
module is enrolled, if it is not detected by the control, the Service LED will illuminate.
DESCRIPTION
DATA
Connect to the NetworX control panel DATA terminal. Data-signaling terminal to all the
devices on the bus.
COM
Connect to the NetworX control panel COMMON terminal. Supplies the common side of the
power to the door control module.
POS
Connect to NetworX control panel AUX POWER + terminal. Supplies power to the door
control module.
+12
Power to reader module, if required.
+5
Power to reader module, if required.
COM
Connect to common terminal of box tamper.
TMPR
Box Tamper
N/C
Normally closed relay contact to activate door strike.
C
Closed relay contact to activate door strike.
N/O
Normally open relay contact to activate door strike.
Rating:
5A 125, 277V AC
5A 30V DC
A-EG
Egress input. To use this feature, connect the normally open egress switch between this
terminal and COM.
A-TM
Tamper input (from Reader “A”)
A-LR
Red LED (LED2) control (to Reader “A”). Relay. If available, connect to LED control on
reader.
A-LG
Green LED (LED1) control (to Reader “A”). Relay. If available, connect to LED control on
reader.
A-BZ
Buzzer control (to Reader “A”).
A-D1
Wiegand Data 1 terminal (from Reader “A”).
Reader “A”
A-D0
Wiegand Data 0 terminal (from Reader “A”).
COM
Common dry contact
B-EG
Egress input. To use this feature, connect the normally open egress switch between this
terminal and COM.
B-RM
Tamper input (from Reader “B”)
B-LR
Red LED (LED2) control (to Reader “B”). Relay. If available, connect to LED control on
reader.
B-LG
Green LED (LED1) control (to Reader “B”). Relay. If available, connect to LED control on
reader.
B-BZ
Buzzer control (to Reader “B”).
B-D1
Wiegand Data 1 terminal (from Reader “B”).
Reader “B”
B-D0
Wiegand Data 0 terminal (from Reader “B”).
COM
Common terminal.
DOOR
Door contact (requires 3.3K end-of-line resistor).
NX-1710E Single Door Control
7
V.
ADDRESSING
The first thing that must be decided is the address of this particular relay/output module. This is the address that
will be selected when programming the auxiliary devices. To set the addresses use the table below. Refer to
Table V-1 that follows for possible addresses.
The door control unit must be powered down and powered back up in order to read
new or modified dip switch settings.
Table V-1
Bus Address
Dip Switch Setting
Bus Address
Dip Switch Setting
1
2
3
4
1
2
3
4
128
136
ON
129
ON
137
ON
ON
130
ON
138
ON
ON
131
ON
ON
139
ON
ON
ON
132
ON
140
ON
ON
133
ON
ON
141
ON
ON
ON
134
ON
ON
142
ON
ON
ON
135
ON
ON
ON
143
ON
ON
ON
ON
VI.
PROGRAMMING
USING THE LED KEYPAD
ENTERING THE PROGRAM MODE
Enters the Program Mode.
Stay, Chime, Exit, Bypass & Cancel LEDS
will flash.
[Go To Program Code]
Factory Default is
If the "Go To Program Code" is valid, the
"Service" LED will flash and the five function
LEDs will illuminate steady. You are now in the
Program Mode and ready to select the module
address.
ENTERING THE MODULE ADDRESS
Scan a card.
#
(example only)
Enter the module address. Refer to Table V-1
for the address.
The Armed LED will illuminate while it is
waiting for a programming location to be
entered.
LOADING THE FACTORY DEFAULTS (USER PROGRAMMING ONLY)
#
The keypad will beep 3 times indicating that
the loading is in progress. The loading takes
about 6 seconds.
DEFAULTING THE CARD SERIAL NUMBERS
#
The keypad will beep 3 times indicating that
the loading is in progress.
NX-1710E Single Door Control
8
PROGRAMMING A LOCATION
If an attempt is made to program an invalid entry for a particular segment, the
keypad sounder will emit a triple error beep (beep, beep, beep), and remain in that
segment awaiting a valid entry.
To Enter a Location:
[location] #
The Armed LED will flash. If the location is
valid, the "Armed" LED will extinguish, the
"Ready" LED will illuminate, and the zone
LED’s will show the data for the first segment
of this location.
To Change Location Data:
[changed data]
The "Ready" LED will flash to indicate a data
change in process and will continue until the
data is saved.
The new data is saved.
The keypad will increment and display the next
segment’s data.
NOTE: Repeat these steps until the last segment is reached.
To Exit a Location:
#
Exits from this location. The “Ready” LED will
extinguish. The "Armed" LED will illuminate
waiting for a new programming location to be
entered.
To Review The Data:
[location] #
The Armed LED will flash. If the location is
valid, the "Armed" LED will extinguish, the
"Ready" LED will illuminate, and the zone
LED’s will show the data for the first segment
of this location.
(Do not enter data.)
The next segment is displayed. Each time r
is pressed, the data of the next segment will
be displayed for review.
Shortcuts:
Previous location.
Same location.
Next sequential location.
EXITING THE PROGRAM MODE:
EXIT EXIT
Exits this programming level.
USING THE LCD KEYPAD
All steps required for programming are the same as the aforementioned LED keypad. The LCD keypad display
will prompt you for the data required. While in the programming mode, and not in a location, the number in
parenthesis is the location you were previously changing. For example, if the display reads "Enter location, then
# (5)", it is reminding you that location 5 was the last location you programmed. In feature selection data, the
numbers of the enabled features will be displayed. The features not enabled will display a hyphen (-).
PROGRAMMING DATA TYPES
1.
Numerical Data can take on values from 0-255 or 0-15 depending on the segment size.
2.
Feature Selection Data is used to turn features on or off.
NX-1710E Single Door Control
9
VII.
USER CARDS
Adding and de-activating users is done through a combination of entering information at the keypad and
scanning cards. Before a card can be entered, one door control on the system must be programmed with User
Card Programming enabled (Location 3, Segment 1, Option 1, page 14).
It is recommended that only one door control on the system be enabled to modify user
cards and that this reader be located near a keypad. This reader will transfer information to
all other readers in the system once programming is finished.
Once a door control is enabled to modify users, it must be placed into one of the following five modes:
1)
Add One User
2)
Add Multiple Users w/ Auto-Increment
3)
Activate One User
4)
De-Activate One User
5)
Delete/Reset One User.
Modifying users on a door control is similar to modifying user codes at a keypad.
ENTER USER PROGRAMMING
Accesses Code Programming
[master code]
Factory Default is
If the code is valid, the Ready LED will flash.
User Number 2 is used to program user
cards, so…
if control is an NX-4, NX-6,
or NX-8
if control is an NX-8E
Unit is now ready for you to choose one of the
User Card Programming modes (as if user
code 2):
$ Add One User
$ Add Multiple Users (w/Auto-Increment)
$ Activate Single User
$ De-activate One User
$ Delete / Reset One User
IMPORTANT NOTES
1. Adding or de-activating user cards from a door control will cause the code for User Number 2 to become
invalid. Therefore, it will need to be re-entered after all user cards are programmed into the door control.
2. By default, user cards are added and activated.
ADDING ONE USER
[STAY]
Accesses Activation mode
[3-digit user number]
Example: if 4-digit user
code or if 6-digit
If a valid user number is entered, LED1
(Green) on any enabled readers will begin to
flash.
Scan the card designated for the user
entered in the previous step.
If the user card is not already in the system, it
will be added and mapped to the entered user
number and LED1 (Green) will flash.
If the card is already in the system, the reader
will triple beep and LED1 (Green) will continue
flashing; the user number is not incremented in
this case.
Must be a
master user in
order to modify
user card
information.
NX-1710E Single Door Control
10
ADDING MULTIPLE USERS WITH AUTO-INCREMENT
[CANCEL]
Accesses Activation mode
[3-digit user number]
Example: if 4-digit user code
or if 6-digit
If a valid user number is entered, LED1
(Green) on any enabled readers will begin
to flash.
Scan the card designated for the user
entered in the previous step.
If the user card is not already in the
system, it will be added and mapped to
the entered user number and LED1
(Green) will continue flashing indicating
that the next user card can be scanned for
the next user number.
If the card is already in the system, the
reader will triple beep and LED1 (Green)
will continue flashing; the user number is
not incremented in this case.
Continue scanning user cards until the
desired number of cards has been added.
After about 30 seconds without a card being
scanned, all the readers in the system will
be updated with the new user card
information.
IMPORTANT NOTE
Activating / De-activating / Resetting Users -- If User Number 0 is entered, the desired
function will be performed on the user associated with the card scanned.
ACTIVATE ONE USER (SINGLE USER)
[CHIME]
Accesses Activation mode
[3-digit user number]
Example: if 4-digit user code or
if 6-digit
If a valid user number is entered, LED1
(Green) on any enabled readers will begin
to flash.
Scan any card.
The card information for the user entered
in the previous step will be activated, and
LED1 (Green) will stop flashing. After
about 30 seconds, all the readers in the
system will be updated.
DE-ACTIVATE ONE USER
[BYPASS]
Accesses De-activation mode
[3-digit user number]
Example: if 4-digit user code
or if 6-digit
If a valid user number is entered, LED1
(Green) on any enabled readers will begin
to flash.
Scan any card
The card information for the user entered
in the previous step will be cleared, and
LED1 (Green) will stop flashing. After
about 30 seconds, all the readers in the
system will be updated.
NX-1710E Single Door Control
11
DELETE / RESET ONE USER
[EXIT]
Accesses De-activation mode
[3-digit user number]
Example: if 4-digit user code or
if 6-digit
If a valid user number is entered, LED1
(Green) on any enabled readers will begin
to flash.
Scan any card
The card information for the user entered
in the previous step will be cleared, and
LED1 (Green) will stop flashing. After
about 30 seconds, all the readers in the
system will be updated.
VIII.
PROGRAMMING LOCATIONS
For the purpose of these instructions, the term “door control” refers to the NX-1710E
module, and the term “reader” refers to the specific card reader attached to the
system.
LOCATION 0
READER “A” SCAN FUNCTIONS & OPTIONS
(8 segments of binary data) Location 0 is used to select the particular function(s) that are activated when a card
is scanned at Reader “A”. More than one function may be selected. If more than one function is selected, they
will execute in order from function 1 to function 8.
Functions 1-6 will be performed based on the user’s authority as programmed by the [] [6]
function (refer to keypad user manual).
Segment 1
Single Scan Function
Program the functions that are performed when a card is scanned {one beep}.
LED1 - "On" to send Code Entry function to the control panel.
LED2 - "On" to activate the Armed Away mode.
LED3 - "On" to activate the Armed Stay mode.
LED4 - "On" to send the Disarm function to the control panel.
LED5 - "On" to send Auxiliary Function #1 to the control panel.
LED6 - "On" to send Auxiliary Function #2 to the control panel.
LED7 - "On" to broadcast an X-10 function (see Location 241 for programming).
LED8 - "On" to send a Request-to-Exit (RTE) and to activate the onboard relay. (Default is
“On”)
Segment 2
Triple Scan Function
Program the functions that are performed when a card is scanned three times {three beeps}. The descriptions
of the options are the same as for Single Scan Function (Segment 1 above). Default is 1.
Segment 3
Reader Options:
LED1 -
"On" if tamper is inverted.
LED2 -
"On" if tamper is enabled.
LED3 -
"On" if reader buzzer is to follow typical keypad buzzing.
LED4 -
"On" if reader automatically issues a beep when the card is scanned. Enabling
this option prevents the door control from issuing another beep. (Default is “On”)
LED5–8
Reserved.
If an individual keeps the card, it can still be deleted.
NX-1710E Single Door Control
12
Segment 4
LED1 (Green) Options:
LED1 -
"On" to follow Ready status of system. (Default is “On”)
LED2 -
"On" to toggle with the relay activation. (Default is “On”)
LED3 -
"On" if inverted.
LED4–8
Reserved.
Segment 5
LED2 (Red) Options:
LED1 -
"On" to follow Armed status of system. (Default is “On”)
LED2 -
"On" to toggle with the relay activation.
LED3 -
"On" if inverted.
LED4–8
Reserved.
Segments 6 – 8 Reserved
LOCATION 1
READER “B” SCAN FUNCTIONS & OPTIONS
(8 segments of binary data) Location 1 is used to select the particular function(s) that are activated when a card
is scanned at Reader “B”. More than one function may be selected. If more than one function is selected, they
will execute in order from function 1 to function 8.
Functions 1-6 will be performed based on the user’s authority as programmed by the [] [6]
function (refer to keypad user manual).
Segment 1
Single Scan Function
Program the functions that are performed when a card is scanned {one beep}.
LED1 -
"On" to send Code Entry function to the control panel.
LED2 -
"On" to activate the Armed Away mode.
LED3 -
"On" to activate the Armed Stay mode.
LED4 -
"On" to send the Disarm function to the control panel.
LED5 -
"On" to send Auxiliary Function #1 to the control panel.
LED6 -
"On" to send Auxiliary Function #2 to the control panel.
LED7 -
"On" to broadcast an X-10 function (see Location 241 for programming).
LED8 -
"On" to send a Request-to-Exit (RTE); and to activate the onboard relay. (Default
is “On”)
Segment 2
Triple Scan Function
Program the functions that are performed when a card is scanned three times {three beeps}. The descriptions
of the options are the same as for Single Scan Function (Segment 1 above). Default is 1.
Segment 3
Reader Options:
LED1 -
"On" if tamper is inverted.
LED2 -
"On" if tamper is enabled.
LED3 -
"On" if reader buzzer is to follow typical keypad buzzing.
LED4 -
"On" if reader automatically issues a beep when the card is scanned. Enabling
this option prevents the door control from issuing another beep. (Default is “On”)
LED5 -
“On” if LEDs to extinguish after 2 minutes without a scan. (Note: This option doesn’t
disable the flashing green LED during card programming.)
LED6–8 Reserved.
Segment 4
LED1 (Green) Options:
LED1 -
"On" to follow Ready status of system. (Default is “On”)
LED2 -
"On" to toggle with the relay activation. (Default is “On”)
LED3 -
"On" if inverted.
LED4–8
Reserved.
NX-1710E Single Door Control
13
Segment 5
LED2 (Red) Options:
LED1 -
"On" to follow Armed status of system. (Default is “On”)
LED2 -
"On" to toggle with the relay activation.
LED3 -
"On" if inverted.
LED4–8
Reserved.
Segments 6 – 8 Reserved
LOCATION 2
PROGRAMMING THE X-10 ADDRESS FOR THE SCAN FUNCTIONS
(6 segments of numerical data)
Segment 1
Module Number
Program a number from 0 -15 to represent the corresponding X-10 Module Number from the following table.
Default is 0.
Module
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16
Seg 1
0
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15
Segment 2
House Code
Program a number from 0-15 to represent the corresponding X-10 House code from the following table. Default
is 0.
X-10 ADDRESS CODES
0=A
4=E
8=I
12=M
1=B
5=F
9=J
13=N
2=C
6=G
10=K
14=O
3=D
7=H
11=L
15=P
Segment 3
Reader “A” Single Scan Function
Program the X-10 function that is performed when a card is scanned {one beep} at Reader “A”. This location
only needs to be programmed if Location 0, Segment 1, Option 7 is set. Use the following table. Default is 2.
Function #
Function performed
Function #
Function performed
0
All units off
4
Dim
1
All lights on
5
Bright
2
On
6
All lights off
3
Off
All others
Reserved
Segment 4
Reader “A” Triple Scan Function
Program the X-10 function that is performed when a card is scanned three times {three beeps} at Reader “A”.
The descriptions of the function codes are the same as for Single Beep Scan Function. This location only needs
to be programmed if Location 0, Segment 2, Option 7 is set. Use the above table. Default is 3.
Segment 5
Reader “B” Single Scan Function
Program the X-10 function that is performed when a card is scanned {one beep} at Reader “B”. This location
only needs to be programmed if Location 0, Segment 1, Option 7 is set. Use the following table. Default is 2.
Segment 6
Reader “B” Triple Scan Function
Program the X-10 function that is performed when a card is scanned three times {three beeps} at Reader “B”.
The descriptions of the function codes are the same as for Single Beep Scan Function. This location only needs
to be programmed if Location 0, Segment 2, Option 7 is set. Use the above table. Default is 3.
NX-1710E Single Door Control
14
LOCATION 3
PROGRAMMING THE OPTIONS AND DOOR CONTROL PARTITIONS
(4 segments of binary data)
Segment 1
Unit Options:
LED1 -
"On" if door control module is enabled for User Card Programming.
LED2 -
"On" if tamper is enabled.
LED3 -
"On" if disabling on-board zone.
LED4 -
Reserved.
LED5 -
“On” if an RTE from a scanned card is to be logged as Code Entry.
LED6 -
“On” if an RTE from a zone or the egress input is logged as Code Entry.
LED7–8
Reserved.
Segment 2
Door Options
LED1 -
"On" if locking mechanism is a Maglock or Drop Bolt.
LED2 -
"On" if access is allowed regardless of Armed status of the system.
LED3 -
"On" if the door is not to be latched unlocked during an open schedule.
LED4 -
"On" if onboard relay only triggers during an open schedule.
LED5 -
“On” if onboard relay only triggers during a close schedule.
LED6 -
“On” if Forced Entry Alarm is logged.
LED7 -
“On” if access allowed without an RTE.
LED8 -
“On” if relay operates normally during off-schedule (outside regular operating hours).
Segment 3
Enabling the Schedules for the Onboard Relay:
LED1 -
"On" if driver follows Schedule 1. (Default is “On”)
LED2 -
"On" if driver follows Schedule 2. (Default is “On”)
LED3 -
"On" if driver follows Schedule 3. (Default is “On”)
LED4 -
"On" if driver follows Schedule 4. (Default is “On”)
LED5 -
"On" if driver follows Schedule 5. (Default is “On”)
LED6 -
"On" if driver follows Schedule 6. (Default is “On”)
LED7 -
"On" if driver follows Schedule 7. (Default is “On”)
LED8 -
"On" if driver follows Schedule 8. (Default is “On”)
Segment 4
Door Control Partition:
LED1 -
"On" if door control is in Partition 1. (Default is “On”)
LED2 -
"On" if door control is in Partition 2. (Default is “On”)
LED3 -
"On" if door control is in Partition 3. (Default is “On”)
LED4 -
"On" if door control is in Partition 4. (Default is “On”)
LED5 -
"On" if door control is in Partition 5. (Default is “On”)
LED6 -
"On" if door control is in Partition 6. (Default is “On”)
LED7 -
"On" if door control is in Partition 7. (Default is “On”)
LED8 -
"On" if door control is in Partition 8. (Default is “On”)
Segment 5
Weigand Format Enables:
LED1 - "On" if Weigand Format #1 is enabled. (Default is “On”)
LED2 - "On" if Weigand Format #2 is enabled. (Default is “On”)
LED3 - "On" if Weigand Format #3 is enabled. (Default is “On”)
LED4 - "On" if Weigand Format #4 is enabled. (Default is “On”)
LED5 - "On" if Weigand Format #5 is enabled. (Default is “On”)
LED6 - "On" if Weigand Format #6 is enabled.
LED7 - "On" if Weigand Format #7 is enabled.
LED8 - "On" if Weigand Format #8 is enabled.
NX-1710E Single Door Control
15
LOCATION 4
PROGRAMMING THE ZONES
(2 segments of numerical data)
Segment 1
Door Shunt Zone
Program the zone that will be monitored as a door for access control. This location must be programmed with a
valid zone for monitored access control functions to work properly. (Default is 0)
Additionally, this zone must be configured in the control panel as a Door Shunt zone by
programming an unused Zone Type Characteristic in locations 111-169 (Seg 4, Opt 4).
Segment 2
Request To Exit (RTE) Zone
Program the zone that will be monitored to signal an RTE. If this segment is programmed with a valid zone and
the zone is faulted, the reader will activate its onboard relay and send the RTE. (Default is 0)
Additionally, this zone must be configured in the control panel as an RTE zone by
programming an unused Zone Type Characteristic in locations 111-169 (Seg 4, Opt 3).
LOCATION 5
PROGRAMMING THE VARIOUS READER TIMERS
(4 segment of numerical data)
Segment 1
Scan Time
Enter the amount of time required to hold a card between beeps to activate the functions programmed in
Location 0, Segments 2 and 3. This timer is timed in 1/100-second increments from 0 to 2.55 seconds. (Default
is 100 = 1 second).
Segment 2
Relay Active Time
Enter the amount of time the onboard relay is energized once activated. This timer is timed in 1-second
increments from 0 to 255 seconds. (Default is 10 = 10 seconds).
Segment 3
Door Fault Warning Time
Enter the amount of time a monitored zone (see Location 4, Segment 1) must be faulted before sounding a
warning (local buzzer). The door fault warning is timed in 1-second increments from 0 to 255 seconds. (Default
is 30 = 30 seconds).
Segment 4
Door Fault Alarm Time
Enter the amount of time a monitored zone (see Location 4, Segment 1) must be faulted before sending an
alarm condition to the control panel. The door fault alarm is timed in 1-second increments from 0 to 255
seconds. (Default is 60 = 60 seconds).
LOCATION 6
PROGRAMMING THE OPENING TIME FOR SCHEDULE 1
(2 segments of numerical data)
Segment 1
Program the hour of the opening time in 24-hour format. (Default is 8 = 8:00 AM)
Segment 2
Program the minutes after the hour of the opening time for Schedule 1. (Default is 0)
LOCATION 7
PROGRAMMING THE CLOSING TIME FOR SCHEDULE 1
(2 segments of numerical data)
Segment 1
Program the hour of the closing time in 24-hour format. (Default is 20 = 8:00 PM)
Segment 2
Program the minutes after the hour of the closing time for Schedule 1. (Default is 0)
NX-1710E Single Door Control
16
LOCATION 8
PROGRAMMING THE DAYS FOR SCHEDULE 1
(1 segment of binary data)
LED1 =
"On" if schedule is active on Sunday.
LED2 =
"On" if schedule is active on Monday.
LED3 =
"On" if schedule is active on Tuesday.
LED4 =
"On" if schedule is active on Wednesday.
LED5 =
“On” if schedule is active on Thursday.
LED6 =
“On” if schedule is active on Friday.
LED7 =
“On” if schedule is active on Saturday.
LED8 =
“On” if schedule is disabled on holidays.
LOCATIONS 9 - 29
PROGRAMMING THE SCHEDULES 2 - 8
Locations 9 – 29 are used to program the opening times, closing times, and days for Schedules 2 - 8. Each
schedule has three locations that are programmed with the same steps as Schedule 1 described previously.
Refer to Schedule 1 (Locations 6 - 8 above) for specific instructions.
Location 9 – Opening Time for Schedule 2
Location 21 – Opening Time for Schedule 6
Location 10 – Closing Time for Schedule 2
Location 22 – Closing Time for Schedule 6
Location 11 – Days for Schedule 2
Location 23 – Days for Schedule 6
Location 12 – Opening Time for Schedule 3
Location 24 – Opening Time for Schedule 7
Location 13 – Closing Time for Schedule 3
Location 25 – Closing Time for Schedule 7
Location 14 – Days for Schedule 3
Location 26 – Days for Schedule 7
Location 15 – Opening Time for Schedule 4
Location 27 – Opening Time for Schedule 8
Location 16 – Closing Time for Schedule 4
Location 28 – Closing Time for Schedule 8
Location 17 – Days for Schedule 4
Location 29 – Days for Schedule 8
Location 18 – Opening Time for Schedule 5
Location 19 – Closing Time for Schedule 5
Location 20 – Days for Schedule 5
LOCATION 30
PROGRAMMING THE DATE OF HOLIDAYS IN JANUARY
(8 segments of numerical data) Program the day of the month in January that the Opening time in a schedule is
suppressed. For example, if the opening should not occur on January 1, program a “1” in Segment 1. This
feature can be repeated up to a maximum of 8 holidays per location (month). (Default is No holidays)
LOCATIONS 31 - 41
PROGRAMMING THE DATE OF HOLIDAYS FROM FEBRUARY TO
DECEMBER
(8 segments of numerical data) Locations 31 - 41 are used to program the day of each month, from February to
December, in which the Opening time in a schedule is suppressed. Each location will accommodate up to a
maximum of 8 holidays, and programmed with the same steps as Location 30 described previously.
Location 31 – February holidays
Location 32 – March holidays
Location 33 – April holidays
Location 34 – May holidays
Location 35 – June holidays
Location 36 – July holidays
Location 37 – August holidays
Location 38 – September holidays
Location 39 – October holidays
Location 40 – November holidays
Location 41 – December holidays
NX-1710E Single Door Control
17
LOCATION 42
ACTIVATION DATA FOR USER CARDS 1 - 120
(15 segments of binary data)
This location is used to select which user cards 1 through 120 are activated. If the LED is “on”, the card is
active. Each segment has 8 LEDs corresponding to the 8 possible user cards. Example: Segment 4, LED 2
indicates that user card 26 is active.
Segment 1
User Cards 1 - 8
Segment 9
User Cards 65 - 72
Segment 2
User Cards 9 - 16
Segment 10
User Cards 73 - 80
Segment 3
User Cards 17 - 24
Segment 11
User Cards 81 - 88
Segment 4
User Cards 25 - 32
Segment 12
User Cards 89 - 96
Segment 5
User Cards 33 - 40
Segment 13
User Cards 97 - 104
Segment 6
User Cards 41 - 48
Segment 14
User Cards 105 - 112
Segment 7
User Cards 49 - 56
Segment 15
User Cards 113 - 120
Segment 8
User Cards 57 - 64
LOCATION 43
PROGRAMMING ACTIVATION DATA FOR USER CARDS 121 - 240
(15 segments of binary data) This location is used to select which user cards 121 through 240 are activated. If
the LED is “on”, the card is active. Each segment has 8 LEDs corresponding to the 8 possible user cards.
Example: Segment 15, LED 8 indicates that user card 240 is active.
Segment 1
User Cards 121 - 128
Segment 9
User Cards 185 - 192
Segment 2
User Cards 129 - 136
Segment 10
User Cards 193 - 200
Segment 3
User Cards 137 - 144
Segment 11
User Cards 201 - 208
Segment 4
User Cards 145 - 152
Segment 12
User Cards 209 - 216
Segment 5
User Cards 153 - 160
Segment 13
User Cards 217 - 224
Segment 6
User Cards 161 - 168
Segment 14
User Cards 225 - 232
Segment 7
User Cards 169 – 176
Segment 15
User Cards 233 - 240
Segment 8
User Cards 177 - 184
LOCATION 44
CODE ENTRY LOGGING PARTITION
(2 segments of numerical data) This location programs the partition that is logged with the Code Entry
message and sent when the following conditions are met:
An RTE scan function is selected (Location 0, Segment 1/2, Option 8); and
“RTE from a scanned card is to be logged as Code Entry” is enabled (Location 3, Segment 1, Option 5).
Entering a 0 (zero) will send the lowest valid partition of the reader. Entering 1-16 will send the entered value as
the partition. (Default is 0.)
Segment 1
Code Entry Logging Partition for Reader “A”
Segment 2
Code Entry Logging Partition for Reader “B”
LED1 = Card 1
LED2 = Card 2
LED3 = Card 3
LED4 = Card 4
LED5 = Card 5
LED6 = Card 6
LED7 = Card 7
LED8 = Card 8
LED1 = Card 1
LED2 = Card 2
LED3 = Card 3
LED4 = Card 4
LED5 = Card 5
LED6 = Card 6
LED7 = Card 7
LED8 = Card 8
NX-1710E Single Door Control
18
USER-DEFINABLE FORMATS
The following locations are considered to be advanced programming and should
ONLY be used by installers with a thorough understanding of Weigand Formats. Do
not attempt to program these locations if you are not familiar with Weigand packets.
LOCATION 45
WEIGAND FORMAT 1 (STANDARD 26 BIT) – DIGITS & BITS
(5 segments of decimal data) This is the first location used to program the Weigand Format 1. (Loc 45-57)
Segment 1
Number of digits in Facility Code
Segment 2
Number of digits in Badge Number
Segment 3
Number of bits in Facility Code
Segment 4
Number of bits in Badge Number
Segment 5
Total number of bits in complete format (including parity bits)
LOCATION 46
WEIGAND FORMAT 1 – BIT DESCRIPTORS (BITS 1-32)
(32 segments of hex data) This location contains the descriptors for bits 1 – 32 of Weigand Format 1. The
available options are: 0=Always Zero; 1=Always One; B=Badge number; D=Parity bit; E=End of
format; F=Facility Code bit. Segment 1 = Bit Descriptor 1; Segment 32 = Bit Descriptor 32.
LOCATION 47
WEIGAND FORMAT 1 – BIT DESCRIPTORS (BITS 33-64)
(32 segments of hex data) This location contains the descriptors for bits 33 – 64 of Weigand Format 1.
The available options are: 0=Always Zero; 1=Always One; B=Badge number; D=Parity bit; E=End of
format; F=Facility Code bit. Segment 1 = Bit Descriptor 33; Segment 32 = Bit Descriptor 64.
LOCATION 48
WEIGAND FORMAT 1 – PARITY TYPE 1
(1 segment of decimal data) This location programs the Partity Type 1 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 1.
LOCATION 49
WEIGAND FORMAT 1 – PARITY MASK 1
(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 48 (Parity Type 1). The factory default is:
Seg 1
Seg 2
Seg 3
Seg 4
Seg 5
Seg 6
Seg 7
Seg 8
12345678
12345678
12345678
------78
--------
--------
--------
--------
LOCATION 50
WEIGAND FORMAT 1 – PARITY TYPE 2
(1 segment of decimal data) This location programs the Partity Type 2 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 2.
LOCATION 51
WEIGAND FORMAT 1 – PARITY MASK 2
(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 50 (Parity Type 2). The factory default is:
Seg 1
Seg 2
Seg 3
Seg 4
Seg 5
Seg 6
Seg 7
Seg 8
12345678
---45678
--------
--------
--------
--------
--------
--------
LOCATION 52
WEIGAND FORMAT 1 – PARITY TYPE 3
(1 segment of decimal data) This location programs the Partity Type 3 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 0.
LOCATION 53
WEIGAND FORMAT 1 – PARITY MASK 3
(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 52 (Parity Type 3). The factory default is:
Seg 1
Seg 2
Seg 3
Seg 4
Seg 5
Seg 6
Seg 7
Seg 8
--------
--------
--------
--------
--------
--------
--------
--------
NX-1710E Single Door Control
19
LOCATION 54
WEIGAND FORMAT 1 – PARITY TYPE 4
(1 segment of decimal data) This location programs the Partity Type 4 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 0.
LOCATION 55
WEIGAND FORMAT 1 – PARITY MASK 4
(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 54 (Parity Type 4). The factory default is:
Seg 1
Seg 2
Seg 3
Seg 4
Seg 5
Seg 6
Seg 7
Seg 8
--------
--------
--------
--------
--------
--------
--------
--------
LOCATION 56
WEIGAND FORMAT 1 – PARITY TYPE 5
(1 segment of decimal data) This location programs the Partity Type 5 for Weigand Format 1. Available options
for this location are 0 = No Parity; 1 = Odd Parity; 2 = Even Parity. Factory default is 0.
LOCATION 57
WEIGAND FORMAT 1 – PARITY MASK 5
(8 segments of binary data) This location tells which bits to include for the parity count; and includes the parity
bits. It is used in conjunction with Location 56 (Parity Type 5). The factory default is:
Seg 1
Seg 2
Seg 3
Seg 4
Seg 5
Seg 6
Seg 7
Seg 8
--------
--------
--------
--------
--------
--------
--------
--------
LOCATIONS 58 – 70
WEIGAND FORMAT 2 (TECOM ASC 27 BIT)
These locations contain the programming for Weigand Format 2. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
LOCATIONS 71 - 83
WEIGAND FORMAT 3 (HID1000)
These locations contain the programming for Weigand Format 3. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
LOCATIONS 84 – 96
WEIGAND FORMAT 4 (H10304)
These locations contain the programming for Weigand Format 4. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
LOCATIONS 97 - 109
WEIGAND FORMAT 5 (40 BIT W/FACILITY CODE – CASI 4001)
These locations contain the programming for Weigand Format 5. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
LOCATIONS 110 - 122
WEIGAND FORMAT 6 (40 BIT W/O FACILITY CODE – CASI 4002)
These locations contain the programming for Weigand Format 6. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
LOCATIONS 123 - 135
WEIGAND FORMAT 7 (UNDEFINED)
These locations contain the programming for Weigand Format 7. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
LOCATIONS 136 - 148
WEIGAND FORMAT 8 (UNDEFINED)
These locations contain the programming for Weigand Format 8. Refer to the instructions for Locations 45 – 57
regarding the Bit Descriptors, Parity Types and Parity Masks 1-5. Factory defaults are in the worksheets.
NX-1710E Single Door Control
20
Tip:
Defaults are shown in bold italics.
IX.
PROGRAMMING WORKSHEETS
SEG
DESCRIPTION
LOCATION 0 – READER “A” SCAN FUNCTIONS & OPTIONS
1 SINGLE SCAN FUNCTION
1 = "On" to send Code Entry function to the control panel.
2 = "On" to activate the Armed Away mode.
3 = "On" to activate the Armed Stay mode.
4 = "On" to send the Disarm function to the control panel.
5 = "On" to send Auxiliary Function #1 to the control panel.
6 = "On" to send Auxiliary Function #2 to the control panel.
7 = "On" to broadcast an X-10 function (see Location 2).
8 = "On" to send a Request To Exit (RTE); and activate the onboard relay
2 TRIPLE SCAN FUNCTION
1 = "On" to send Code Entry function to the control panel.
2 = "On" to activate the Armed Away mode.
3 = "On" to activate the Armed Stay mode.
4 = "On" to send the Disarm function to the control panel.
5 = "On" to send Auxiliary Function #1 to the control panel.
6 = "On" to send Auxiliary Function #2 to the control panel.
7 = "On" to broadcast an X-10 function (see Loc 2).
8 = "On" to send an RTE & activate the onboard relay.
3 READER OPTIONS
1 = "On" if tamper is inverted.
2 = "On" if tamper is enabled.
3 = "On" if reader buzzer is to follow typical keypad buzzing.
4 = “On" if reader automatically issues a beep when a card is scanned.
5-8 Reserved.
4 LED1 (GREEN) OPTIONS
1 = "On" to follow Ready status of system.
2 = "On" to toggle with the relay activation.
3 = "On" if inverted.
5-8
Reserved.
5 LED2 (RED) OPTIONS
1 = "On" to follow Armed status of system.
2 = "On" to toggle with the relay activation.
3 = "On" if inverted.
4-8 Reserved.
6-8 RESERVED
LOCATION 1 – READER “B” SCAN FUNCTIONS & OPTIONS
1 SINGLE SCAN FUNCTION
1 = "On" to send Code Entry function to the control panel.
2 = "On" to activate the Armed Away mode.
3 = "On" to activate the Armed Stay mode.
4 = "On" to send the Disarm function to the control panel.
5 = "On" to send Auxiliary Function #1 to the control panel.
6 = "On" to send Auxiliary Function #2 to the control panel.
7 = "On" to broadcast an X-10 function (see Location 2).
8 = "On" to send a Request To Exit (RTE); and activate the onboard relay.
2 TRIPLE SCAN FUNCTION
1 = "On" to send Code Entry function to the control panel.
2 = "On" to activate the Armed Away mode.
3 = "On" to activate the Armed Stay mode.
4 = "On" to send the Disarm function to the control panel.
5 = "On" to send Auxiliary Function #1 to the control panel.
6 = "On" to send Auxiliary Function #2 to the control panel.
7 = "On" to broadcast an X-10 function (see Loc 2).
8 = "On" to send an RTE & activate the onboard relay.
3 READER OPTIONS
1 = "On" if tamper is inverted.
2 = "On" if tamper is enabled.
3 = "On" if reader buzzer is to follow typical keypad buzzing.
4 = “On" if reader automatically issues a beep when a card is scanned.
5 = “On” if LEDs to extinguish after 2 minutes without a scan.
6-8 Reserved.
4 LED1 (GREEN) OPTIONS
1 = "On" to follow Ready status of system.
2 = "On" to toggle with the relay activation.
3 = "On" if inverted.
4-8
Reserved.
NX-1710E Single Door Control
21
SEG
DESCRIPTION
5 LED2 (RED) OPTIONS
1 = "On" to follow Armed status of system.
2 = "On" to toggle with the relay activation.
3 = "On" if inverted.
4-8 Reserved.
6-8 RESERVED
LOCATION 2 – X10 ADDRESS
1 MODULE NUMBER
0 = Module 1
1 = Module 2
2 = Module 3
3 = Module 4
4 = Module 5
5 = Module 6
6 = Module 7
7 = Module 8
8 = Module 9
9 = Module 10
10 = Module 11
11 = Module 12
12 = Module 13
13 = Module 14
14 = Module 15
15 = Module 16
2 HOUSE CODE
0 = A
1 = B
2 = C
3 = D
4 = E
5 = F
6 = G
7 = H
8 = I
9 = J
10 = K
11 = L
12 = M
13 = N
14 = O
15 = P
3 READER “A” SINGLE SCAN
0 = All units off
1 = All lights on
2 = On
3 = Off
4 = Dim
5 = Bright
6 = All lights off
7 = All others = Reserved
4 READER “A” TRIPLE SCAN
0 = All units off
1 = All lights on
2 = On
3 = Off
4 = Dim
5 = Bright
6 = All lights off
7 = All others = Reserved
5 READER “B” SINGLE SCAN
0 = All units off
1 = All lights on
2 = On
3 = Off
4 = Dim
5 = Bright
6 = All lights off
7 = All others = Reserved
6 READER “B” TRIPLE SCAN
0 = All units off
1 = All lights on
2 = On
3 = Off
4 = Dim
5 = Bright
6 = All lights off
7 = All others = Reserved
LOCATION 3 – OPTIONS & DOOR CONTROL PARTITION
1 UNIT OPTIONS
1 = "On" if enabled for User Card Programming
2 = "On" if tamper enabled
3 = "On" if on-board zone is disabled
4 = Reserved.
5 = “On” if an RTE from a scanned card is to be logged as Code Entry
6 = “On” if an RTE from a zone or the egress input is to be logged as Code Entry
7-8 = Reserved
2 DOOR OPTIONS
1 = "On" if locking mechanism is a Maglock or Drop Bolt.
2 = "On" if access is allowed regardless of Armed status of the system.
3 = "On" if the door is not to be latched unlocked during an open schedule.
4 = "On" if onboard relay only triggers during an open schedule.
5 = “On” if onboard relay only triggers during a close schedule.
6 = “On” if Forced Entry Alarm is logged.
7 = “On” if access allowed without an RTE.
8 = “On” if relay operates normally during off-schedule (outside of regular operating hours).
3 ENABLING THE SCHEDULES FOR THE ONBOARD RELAY
1 = "On" if driver follows Schedule 1.
2 = "On" if driver follows Schedule 2.
3 = "On" if driver follows Schedule 3.
4 = "On" if driver follows Schedule 4.
5 = "On" if driver follows Schedule 5.
6 = "On" if driver follows Schedule 6.
7 = "On" if driver follows Schedule 7.
8 = "On" if driver follows Schedule 8.
4 READER PARTITION
1 = "On" if door control is in Partition 1
2 = "On" if door control is in Partition 2
3 = "On" if door control is in Partition 3
4 = "On" if door control is in Partition 4
5 = "On" if door control is in Partition 5
6 = "On" if door control is in Partition 6
7 = "On" if door control is in Partition 7
8 = "On" if door control is in Partition 8
NX-1710E Single Door Control
22
SEG
DESCRIPTION
5 WEIGAND FORMAT ENABLES
1 = Weigand format # 1
2 = Weigand format # 2
3 = Weigand format # 3
4 = Weigand format # 4
5 = Weigand format # 5
6 = Weigand format # 6
7 = Weigand format # 7
8 = Weigand format # 8
LOCATION 4 – PROGRAMMING THE ZONES
1 DOOR SHUNT ZONE
Default = 0
Additionally, this zone must be configured in the control panel as a Door Shunt zone by programming an unused
Zone Type Characteristic in locations 111-169 (Seg 4, Opt 4).
2 REQUEST TO EXIT (RTE) ZONE
Default = 0
Additionally, this zone must be configured in the control panel as an RTE zone by programming an unused Zone
Type Characteristic in locations 111-169 (Seg 4, Opt 3).
LOCATION 5 – READER TIMERS
1 Scan Time (1/100 seconds)
Default = 100 (1 second)
2 Relay Active Time (seconds)
Default = 10
3 Door Fault Warning Time (seconds)
Default = 30
4 Door Fault Alarm Time (seconds)
Default = 60
LOCATION 6 – OPENING TIME FOR SCHEDULE 1
1 Hour of Opening (24-hr format)
Default = 8 (8 AM)
2 Minutes after Hour of Opening
Default = 0
LOCATION 7 – CLOSING TIME FOR SCHEDULE 1
1 Hour of Closing (24-hr format)
Default =20 (8 PM)
2 Minutes after Hour of Closing
Default = 0
LOCATION 8 – DAYS FOR SCHEDULE 1
1 = "On" if schedule is active on Sunday.
2 = "On" if schedule is active on Monday.
3 = "On" if schedule is active on Tuesday.
4 = "On" if schedule is active on Wednesday.
5 = “On” if schedule is active on Thursday.
6 = “On” if schedule is active on Friday.
7 = “On” if schedule is active on Saturday.
8 = “On” if schedule is disabled on holidays.
LOCATION 9 – OPENING TIME FOR SCHEDULE 2
1 Hour of Opening (24-hr format)
Default = 8 (8 AM)
2 Minutes after Hour of Opening
Default = 0
LOCATION 10 – CLOSING TIME FOR SCHEDULE 2
1 Hour of Closing (24-hr format)
Default =20 (8 PM)
2 Minutes after Hour of Closing
Default = 0
LOCATION 11 – DAYS FOR SCHEDULE 2
1 = "On" if schedule is active on Sunday.
2 = "On" if schedule is active on Monday.
3 = "On" if schedule is active on Tuesday.
4 = "On" if schedule is active on Wednesday.
5 = “On” if schedule is active on Thursday.
6 = “On” if schedule is active on Friday.
7 = “On” if schedule is active on Saturday.
8 = “On” if schedule is disabled on holidays.
LOCATION 12 – OPENING TIME FOR SCHEDULE 3
1 Hour of Opening (24-hr format)
Default = 8 (8 AM)
2 Minutes after Hour of Opening
Default = 0
LOCATION 13 – CLOSING TIME FOR SCHEDULE 3
1 Hour of Closing (24-hr format)
Default =20 (8 PM)
2 Minutes after Hour of Closing
Default = 0
LOCATION 14 – DAYS FOR SCHEDULE 3
1 = "On" if schedule is active on Sunday.
2 = "On" if schedule is active on Monday.
3 = "On" if schedule is active on Tuesday.
4 = "On" if schedule is active on Wednesday.
5 = “On” if schedule is active on Thursday.
6 = “On” if schedule is active on Friday.
7 = “On” if schedule is active on Saturday.
8 = “On” if schedule is disabled on holidays.
NX-1710E Single Door Control
23
SEG
DESCRIPTION
LOCATION 15 – OPENING TIME FOR SCHEDULE 4
1 Hour of Opening (24-hr format)
Default = 8 (8 AM)
2 Minutes after Hour of Opening
Default = 0
LOCATION 16 – CLOSING TIME FOR SCHEDULE 4
1 Hour of Closing (24-hr format)
Default =20 (8 PM)
2 Minutes after Hour of Closing
Default = 0
LOCATION 17 – DAYS FOR SCHEDULE 4
1 = "On" if schedule is active on Sunday.
2 = "On" if schedule is active on Monday.
3 = "On" if schedule is active on Tuesday.
4 = "On" if schedule is active on Wednesday.
5 = “On” if schedule is active on Thursday.
6 = “On” if schedule is active on Friday.
7 = “On” if schedule is active on Saturday.
8 = “On” if schedule is disabled on holidays.
LOCATION 18 – OPENING TIME FOR SCHEDULE 5
1 Hour of Opening (24-hr format)
Default = 8 (8 AM)
2 Minutes after Hour of Opening
Default = 0
LOCATION 19 – CLOSING TIME FOR SCHEDULE 5
1 Hour of Closing (24-hr format)
Default =20 (8 PM)
2 Minutes after Hour of Closing
Default = 0
LOCATION 20 – DAYS FOR SCHEDULE 5
1 = "On" if schedule is active on Sunday.
2 = "On" if schedule is active on Monday.
3 = "On" if schedule is active on Tuesday.
4 = "On" if schedule is active on Wednesday.
5 = “On” if schedule is active on Thursday.
6 = “On” if schedule is active on Friday.
7 = “On” if schedule is active on Saturday.
8 = “On” if schedule is disabled on holidays.
LOCATION 21 – OPENING TIME FOR SCHEDULE 6
1 Hour of Opening (24-hr format)
Default = 8 (8 AM)
2 Minutes after Hour of Opening
Default = 0
LOCATION 22 – CLOSING TIME FOR SCHEDULE 6
1 Hour of Closing (24-hr format)
Default =20 (8 PM)
2 Minutes after Hour of Closing
Default = 0
LOCATION 23 – DAYS FOR SCHEDULE 6
1 = "On" if schedule is active on Sunday.
2 = "On" if schedule is active on Monday.
3 = "On" if schedule is active on Tuesday.
4 = "On" if schedule is active on Wednesday.
5 = “On” if schedule is active on Thursday.
6 = “On” if schedule is active on Friday.
7 = “On” if schedule is active on Saturday.
8 = “On” if schedule is disabled on holidays.
LOCATION 24 – OPENING TIME FOR SCHEDULE 7
1 Hour of Opening (24-hr format)
Default = 8 (8 AM)
2 Minutes after Hour of Opening
Default = 0
LOCATION 25 – CLOSING TIME FOR SCHEDULE 7
1 Hour of Closing (24-hr format)
Default =20 (8 PM)
2 Minutes after Hour of Closing
Default = 0
LOCATION 26 – DAYS FOR SCHEDULE 7
1 = "On" if schedule is active on Sunday.
2 = "On" if schedule is active on Monday.
3 = "On" if schedule is active on Tuesday.
4 = "On" if schedule is active on Wednesday.
5 = “On” if schedule is active on Thursday.
6 = “On” if schedule is active on Friday.
7 = “On” if schedule is active on Saturday.
8 = “On” if schedule is disabled on holidays.
LOCATION 27 – OPENING TIME FOR SCHEDULE 8
1 Hour of Opening (24-hr format)
Default = 8 (8 AM)
2 Minutes after Hour of Opening
Default = 0
LOCATION 28 – CLOSING TIME FOR SCHEDULE 8
1 Hour of Closing (24-hr format)
Default =20 (8 PM)
2 Minutes after Hour of Closing
Default = 0
NX-1710E Single Door Control
24
SEG
DESCRIPTION
LOCATION 29 – DAYS FOR SCHEDULE 8
1 = "On" if schedule is active on Sunday.
2 = "On" if schedule is active on Monday.
3 = "On" if schedule is active on Tuesday.
4 = "On" if schedule is active on Wednesday.
5 = “On” if schedule is active on Thursday.
6 = “On” if schedule is active on Friday.
7 = “On” if schedule is active on Saturday.
8 = “On” if schedule is disabled on holidays.
LOCATION 30 – HOLIDAYS IN JANUARY
Default = 0
__ __ __ __ __ __ __ __
LOCATION 31 – HOLIDAYS IN FEBRUARY
Default = 0
__ __ __ __ __ __ __ __
LOCATION 32 – HOLIDAYS IN MARCH
Default = 0
__ __ __ __ __ __ __ __
LOCATION 33 – HOLIDAYS IN APRIL
Default = 0
__ __ __ __ __ __ __ __
LOCATION 34 – HOLIDAYS IN MAY
Default = 0
__ __ __ __ __ __ __ __
LOCATION 35 – HOLIDAYS IN JUNE
Default = 0
__ __ __ __ __ __ __ __
LOCATION 36 – HOLIDAYS IN JULY
Default = 0
__ __ __ __ __ __ __ __
LOCATION 37 – HOLIDAYS IN AUGUST
Default = 0
__ __ __ __ __ __ __ __
LOCATION 38 – HOLIDAYS IN SEPTEMBER
Default = 0
__ __ __ __ __ __ __ __
LOCATION 39 – HOLIDAYS IN OCTOBER
Default = 0
__ __ __ __ __ __ __ __
LOCATION 40 – HOLIDAYS IN NOVEMBER
Default = 0
__ __ __ __ __ __ __ __
LOCATION 41 – HOLIDAYS IN DECEMBER
Default = 0
__ __ __ __ __ __ __ __
LOCATION 42 – ACTIVATION DATA FOR USER CARDS 1 – 120
LEDs
1
2
3
4
5
6
7
8
1
User Cards 1 - 8
1
2
3
4
5
6
7
8
2
User Cards 9 - 16
9
10
11
12
13
14
15
16
3
User Cards 17 - 24
17
18
19
20
21
22
23
24
4
User Cards 25 - 32
25
26
27
28
29
30
31
32
5
User Cards 33 – 40
33
34
35
36
37
38
39
40
6
User Cards 41 – 48
41
42
43
44
45
46
47
48
7
User Cards 49 – 56
49
50
51
52
53
54
55
56
8
User Cards 57 – 64
57
58
59
60
61
62
63
64
9
User Cards 65 – 72
65
66
67
68
69
70
71
72
10 User Cards 73 – 80
73
74
75
76
77
78
79
80
11 User Cards 81 – 88
81
82
83
84
85
86
87
88
12 User Cards 89 – 96
89
90
91
92
93
94
95
96
13 User Cards 97 – 104
97
98
99
100
101
102
103
104
14 User Cards 105 – 112
105
106
107
108
109
110
111
112
15 User Cards 113 - 120
113
114
115
116
117
118
119
120
LOCATION 43 – ACTIVATION DATA FOR USER CARDS 121 – 240
LEDs
1
2
3
4
5
6
7
8
1
User Cards 121 - 128
121
122
123
124
125
126
127
128
2
User Cards 129 - 136
129
130
131
132
131
134
135
136
3
User Cards 137 - 144
137
138
139
140
141
142
143
144
4
User Cards 145 - 152
145
146
147
148
149
150
151
152
5
User Cards 153 – 160
153
154
155
156
157
158
159
160
6
User Cards 161 – 168
161
162
163
164
165
166
167
168
7
User Cards 169 – 176
169
170
171
172
173
174
175
176
8
User Cards 177 – 184
177
178
179
180
181
182
183
184
9
User Cards 185 – 192
185
186
187
188
189
190
191
192
10 User Cards 193 – 200
193
194
195
196
197
198
199
200
11 User Cards 201 – 208
201
202
203
204
205
206
207
208
12 User Cards 209 – 216
209
210
211
212
213
214
215
216
13 User Cards 217 – 224
217
218
219
220
221
222
223
224
14 User Cards 225 – 232
225
226
227
228
229
230
231
232
15 User Cards 233 – 240
233
234
235
236
237
238
239
240
LOCATION 44 – CODE ENTRY LOGGING PARTITION
1
Code Entry Logging Partition for Reader “A”
Default = 0
2
Code Entry Logging Partition for Reader “B”
Default = 0
NX-1710E Single Door Control
25
IMPORTANT: THE FOLLOWING LOCATIONS ARE CONSIDERED ADVANCED PROGRAMMING AND
SHOULD ONLY BE USED BY INSTALLERS WITH A THOROUGH UNDERSTANDING OF WEIGAND FORMATS.
DO NOT ATTEMPT TO PROGRAM THESE LOCATIONS IF YOU ARE NOT FAMILIAR WITH WEIGAND PACKETS.
WEIGAND FORMAT 1
LOCATION 45 – WIEGAND FORMAT 1 (DIGITS & BITS) (DECIMAL DATA)
SEG
DESCRIPTION
DEFAULT
DATA
1
Number of Digits in Facility Code
5
2
Number of Digits in Badge Number
5
3
Number of Bits in Facility Code
8
4
Number of Bits in Badge Number
16
5
Total Number of Bits in Complete Weigand Format (including parity bits)
26
LOCATION 46 – WIEGAND FORMAT 1 (BIT DESCRIPTOR 1 - 32) HEX DATA
0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit
SEG
DESCRIPTION
DEFAULT
DATA
SEG
DESCRIPTION
DEFAULT
DATA
1
Bit 1 Descriptor
D
17
Bit 17 Descriptor
B
2
Bit 2 Descriptor
F
18
Bit 18 Descriptor
B
3
Bit 3 Descriptor
F
19
Bit 19 Descriptor
B
4
Bit 4 Descriptor
F
20
Bit 20 Descriptor
B
5
Bit 5 Descriptor
F
21
Bit 21 Descriptor
B
6
Bit 6 Descriptor
F
22
Bit 22 Descriptor
B
7
Bit 7 Descriptor
F
23
Bit 23 Descriptor
B
8
Bit 8 Descriptor
F
24
Bit 24 Descriptor
B
9
Bit 9 Descriptor
F
25
Bit 25 Descriptor
B
10
Bit 10 Descriptor
B
26
Bit 26 Descriptor
D
11
Bit 11 Descriptor
B
27
Bit 27 Descriptor
E
12
Bit 12 Descriptor
B
28
Bit 28 Descriptor
E
13
Bit 13 Descriptor
B
29
Bit 29 Descriptor
E
14
Bit 14 Descriptor
B
30
Bit 30 Descriptor
E
15
Bit 15 Descriptor
B
31
Bit 31 Descriptor
E
16
Bit 16 Descriptor
B
32
Bit 32 Descriptor
E
LOCATION 47 – WIEGAND FORMAT 1 (BIT DESCRIPTOR 33 - 64)
0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit
1
Bit 33 Descriptor
E
17
Bit 49 Descriptor
E
2
Bit 34 Descriptor
E
18
Bit 50 Descriptor
E
3
Bit 35 Descriptor
E
19
Bit 51 Descriptor
E
4
Bit 36 Descriptor
E
20
Bit 52 Descriptor
E
5
Bit 37 Descriptor
E
21
Bit 53 Descriptor
E
6
Bit 38 Descriptor
E
22
Bit 54 Descriptor
E
7
Bit 39 Descriptor
E
23
Bit 55 Descriptor
E
8
Bit 40 Descriptor
E
24
Bit 56 Descriptor
E
9
Bit 41 Descriptor
E
25
Bit 57 Descriptor
E
10
Bit 42 Descriptor
E
26
Bit 58 Descriptor
E
11
Bit 43 Descriptor
E
27
Bit 59 Descriptor
E
12
Bit 44 Descriptor
E
28
Bit 60 Descriptor
E
13
Bit 45 Descriptor
E
29
Bit 61 Descriptor
E
14
Bit 46 Descriptor
E
30
Bit 62 Descriptor
E
15
Bit 47 Descriptor
E
31
Bit 63 Descriptor
E
16
Bit 48 Descriptor
E
32
Bit 64 Descriptor
E
LOCATION 48 – WIEGAND FORMAT 1 (PARITY TYPE 1)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 1
1
LOCATION 49 – WIEGAND FORMAT 1 (PARITY MASK 1)
1
Parity Mask 1
12345678
5
Parity Mask 5
--------
2
Parity Mask 2
12345678
6
Parity Mask 6
--------
3
Parity Mask 3
12345678
7
Parity Mask 7
--------
4
Parity Mask 4
------78
8
Parity Mask 8
--------
LOCATION 50 – WIEGAND FORMAT 1 (PARITY TYPE 2)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 2
2
LOCATION 51 – WIEGAND FORMAT 1 (PARITY MASK 2)
1
Parity Mask 1
12345678
5
Parity Mask 5
--------
2
Parity Mask 2
---45678
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 52 – WIEGAND FORMAT 1 (PARITY TYPE 3)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 3
0
NX-1710E Single Door Control
26
SEG
DESCRIPTION
DEFAULT
DATA
SEG
DESCRIPTION
DEFAULT
DATA
LOCATION 53 – WIEGAND FORMAT 1 (PARITY MASK 3)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 54 – WIEGAND FORMAT 1 (PARITY TYPE 4)
1
Parity Type 4
0
LOCATION 55 – WIEGAND FORMAT 1 (PARITY MASK 4)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 56 – WIEGAND FORMAT 1 (PARITY TYPE 5)
1
Parity Type 5
0
LOCATION 57 – WIEGAND FORMAT 1 (PARITY MASK 5)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
WEIGAND FORMAT 2
LOCATION 58 – WIEGAND FORMAT 2 (DIGITS & BITS) (DECIMAL DATA)
SEG
DESCRIPTION
DEFAULT
DATA
1
Number of Digits in Facility Code
0
2
Number of Digits in Badge Number
9
3
Number of Bits in Facility Code
0
4
Number of Bits in Badge Number
27
5
Total Number of Bits in Complete Weigand
Format (including parity bits)
27
LOCATION 59 – WIEGAND FORMAT 2 (BIT DESCRIPTOR 1 - 32) HEX DATA
0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit
SEG
DESCRIPTION
DEFAULT
DATA
SEG
DESCRIPTION
DEFAULT
DATA
1
Bit 1 Descriptor
B
17
Bit 17 Descriptor
B
2
Bit 2 Descriptor
B
18
Bit 18 Descriptor
B
3
Bit 3 Descriptor
B
19
Bit 19 Descriptor
B
4
Bit 4 Descriptor
B
20
Bit 20 Descriptor
B
5
Bit 5 Descriptor
B
21
Bit 21 Descriptor
B
6
Bit 6 Descriptor
B
22
Bit 22 Descriptor
B
7
Bit 7 Descriptor
B
23
Bit 23 Descriptor
B
8
Bit 8 Descriptor
B
24
Bit 24 Descriptor
B
9
Bit 9 Descriptor
B
25
Bit 25 Descriptor
B
10
Bit 10 Descriptor
B
26
Bit 26 Descriptor
B
11
Bit 11 Descriptor
B
27
Bit 27 Descriptor
B
12
Bit 12 Descriptor
B
28
Bit 28 Descriptor
E
13
Bit 13 Descriptor
B
29
Bit 29 Descriptor
E
14
Bit 14 Descriptor
B
30
Bit 30 Descriptor
E
15
Bit 15 Descriptor
B
31
Bit 31 Descriptor
E
16
Bit 16 Descriptor
B
32
Bit 32 Descriptor
E
LOCATION 60 – WIEGAND FORMAT 2 (BIT DESCRIPTOR 33 - 64)
1
Bit 33 Descriptor
E
17
Bit 49 Descriptor
E
2
Bit 34 Descriptor
E
18
Bit 50 Descriptor
E
3
Bit 35 Descriptor
E
19
Bit 51 Descriptor
E
4
Bit 36 Descriptor
E
20
Bit 52 Descriptor
E
5
Bit 37 Descriptor
E
21
Bit 53 Descriptor
E
6
Bit 38 Descriptor
E
22
Bit 54 Descriptor
E
7
Bit 39 Descriptor
E
23
Bit 55 Descriptor
E
8
Bit 40 Descriptor
E
24
Bit 56 Descriptor
E
9
Bit 41 Descriptor
E
25
Bit 57 Descriptor
E
10
Bit 42 Descriptor
E
26
Bit 58 Descriptor
E
11
Bit 43 Descriptor
E
27
Bit 59 Descriptor
E
12
Bit 44 Descriptor
E
28
Bit 60 Descriptor
E
13
Bit 45 Descriptor
E
29
Bit 61 Descriptor
E
14
Bit 46 Descriptor
E
30
Bit 62 Descriptor
E
15
Bit 47 Descriptor
E
31
Bit 63 Descriptor
E
16
Bit 48 Descriptor
E
32
Bit 64 Descriptor
E
NX-1710E Single Door Control
27
LOCATION 61 – WIEGAND FORMAT 2 (PARITY TYPE 1)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 1
0
LOCATION 62 – WIEGAND FORMAT 2 (PARITY MASK 1)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 63 – WIEGAND FORMAT 2 (PARITY TYPE 2)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 2
0
LOCATION 64 – WIEGAND FORMAT 2 (PARITY MASK 2)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 65 – WIEGAND FORMAT 2 (PARITY TYPE 3)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 3
0
LOCATION 66 – WIEGAND FORMAT 2 (PARITY MASK 3)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 67 – WIEGAND FORMAT 2 (PARITY TYPE 4)
1
Parity Type 4
0
LOCATION 68 – WIEGAND FORMAT 2 (PARITY MASK 4)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 69 – WIEGAND FORMAT 2 (PARITY TYPE 5)
1
Parity Type 5
0
LOCATION 70 – WIEGAND FORMAT 2 (PARITY MASK 5)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
WEIGAND FORMAT 3
LOCATION 71 – WIEGAND FORMAT 3 (DIGITS & BITS) (DECIMAL DATA)
DESCRIPTION
DEFAULT
DATA
1
Number of Digits in Facility Code
4
2
Number of Digits in Badge Number
7
3
Number of Bits in Facility Code
12
4
Number of Bits in Badge Number
20
5
Total Number of Bits in Complete Weigand
Format (including parity bits)
35
LOCATION 72 – WIEGAND FORMAT 3 (BIT DESCRIPTOR 1 - 32) HEX DATA
0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit
SEG
DESCRIPTION
DEFAULT
DATA
SEG
DESCRIPTION
DEFAULT
DATA
1
Bit 1 Descriptor
D
17
Bit 17 Descriptor
B
2
Bit 2 Descriptor
D
18
Bit 18 Descriptor
B
3
Bit 3 Descriptor
F
19
Bit 19 Descriptor
B
4
Bit 4 Descriptor
F
20
Bit 20 Descriptor
B
5
Bit 5 Descriptor
F
21
Bit 21 Descriptor
B
6
Bit 6 Descriptor
F
22
Bit 22 Descriptor
B
7
Bit 7 Descriptor
F
23
Bit 23 Descriptor
B
8
Bit 8 Descriptor
F
24
Bit 24 Descriptor
B
9
Bit 9 Descriptor
F
25
Bit 25 Descriptor
B
10
Bit 10 Descriptor
F
26
Bit 26 Descriptor
B
11
Bit 11 Descriptor
F
27
Bit 27 Descriptor
B
12
Bit 12 Descriptor
F
28
Bit 28 Descriptor
B
13
Bit 13 Descriptor
F
29
Bit 29 Descriptor
B
14
Bit 14 Descriptor
F
30
Bit 30 Descriptor
B
15
Bit 15 Descriptor
B
31
Bit 31 Descriptor
B
16
Bit 16 Descriptor
B
32
Bit 32 Descriptor
B
NX-1710E Single Door Control
28
LOCATION 73 – WIEGAND FORMAT 3 (BIT DESCRIPTOR 33 - 64)
0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit
SEG
DESCRIPTION
DEFAULT
DATA
SEG
DESCRIPTION
DEFAULT
DATA
1
Bit 33 Descriptor
B
17
Bit 49 Descriptor
E
2
Bit 34 Descriptor
B
18
Bit 50 Descriptor
E
3
Bit 35 Descriptor
D
19
Bit 51 Descriptor
E
4
Bit 36 Descriptor
E
20
Bit 52 Descriptor
E
5
Bit 37 Descriptor
E
21
Bit 53 Descriptor
E
6
Bit 38 Descriptor
E
22
Bit 54 Descriptor
E
7
Bit 39 Descriptor
E
23
Bit 55 Descriptor
E
8
Bit 40 Descriptor
E
24
Bit 56 Descriptor
E
9
Bit 41 Descriptor
E
25
Bit 57 Descriptor
E
10
Bit 42 Descriptor
E
26
Bit 58 Descriptor
E
11
Bit 43 Descriptor
E
27
Bit 59 Descriptor
E
12
Bit 44 Descriptor
E
28
Bit 60 Descriptor
E
13
Bit 45 Descriptor
E
29
Bit 61 Descriptor
E
14
Bit 46 Descriptor
E
30
Bit 62 Descriptor
E
15
Bit 47 Descriptor
E
31
Bit 63 Descriptor
E
16
Bit 48 Descriptor
E
32
Bit 64 Descriptor
E
LOCATION 74 – WIEGAND FORMAT 3 (PARITY TYPE 1)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 1
1
LOCATION 75 – WIEGAND FORMAT 3 (PARITY MASK 1)
1
Parity Mask 1
12345678
5
Parity Mask 5
-----678
2
Parity Mask 2
12345678
6
Parity Mask 6
--------
3
Parity Mask 3
12345678
7
Parity Mask 7
--------
4
Parity Mask 4
12345678
8
Parity Mask 8
--------
LOCATION 76 – WIEGAND FORMAT 3 (PARITY TYPE 2)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 2
1
LOCATION 77 – WIEGAND FORMAT 3 (PARITY MASK 2)
1
Parity Mask 1
1-34-67-
5
Parity Mask 5
-----6-8
2
Parity Mask 2
-23-56-8
6
Parity Mask 6
--------
3
Parity Mask 3
12-45-78
7
Parity Mask 7
--------
4
Parity Mask 4
1-34-67-
8
Parity Mask 8
--------
LOCATION 78 – WIEGAND FORMAT 3 (PARITY TYPE 3)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 3
2
LOCATION 79 – WIEGAND FORMAT 3 (PARITY MASK 3)
1
Parity Mask 1
-23-567-
5
Parity Mask 5
------78
2
Parity Mask 2
12-45-78
6
Parity Mask 6
--------
3
Parity Mask 3
1-34-67-
7
Parity Mask 7
--------
4
Parity Mask 4
-23-56-8
8
Parity Mask 8
--------
LOCATION 80 – WIEGAND FORMAT 3 (PARITY TYPE 4)
1
Parity Type 4
0
LOCATION 81 – WIEGAND FORMAT 3 (PARITY MASK 4)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 82 – WIEGAND FORMAT 3 (PARITY TYPE 5)
1
Parity Type 5
0
LOCATION 83 – WIEGAND FORMAT 3 (PARITY MASK 5)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
WEIGAND FORMAT 4
LOCATION 84 – WIEGAND FORMAT 4 (DIGITS & BITS) (DECIMAL DATA)
DESCRIPTION
DEFAULT
DATA
1
Number of Digits in Facility Code
5
2
Number of Digits in Badge Number
6
3
Number of Bits in Facility Code
16
4
Number of Bits in Badge Number
19
5
Total Number of Bits in Complete Weigand
Format (including parity bits)
37
NX-1710E Single Door Control
29
LOCATION 85 – WIEGAND FORMAT 4 (BIT DESCRIPTOR 1 - 32) HEX DATA
0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit
SEG
DESCRIPTION
DEFAULT
DATA
SEG
DESCRIPTION
DEFAULT
DATA
1
Bit 1 Descriptor
D
17
Bit 17 Descriptor
F
2
Bit 2 Descriptor
F
18
Bit 18 Descriptor
B
3
Bit 3 Descriptor
F
19
Bit 19 Descriptor
B
4
Bit 4 Descriptor
F
20
Bit 20 Descriptor
B
5
Bit 5 Descriptor
F
21
Bit 21 Descriptor
B
6
Bit 6 Descriptor
F
22
Bit 22 Descriptor
B
7
Bit 7 Descriptor
F
23
Bit 23 Descriptor
B
8
Bit 8 Descriptor
F
24
Bit 24 Descriptor
B
9
Bit 9 Descriptor
F
25
Bit 25 Descriptor
B
10
Bit 10 Descriptor
F
26
Bit 26 Descriptor
B
11
Bit 11 Descriptor
F
27
Bit 27 Descriptor
B
12
Bit 12 Descriptor
F
28
Bit 28 Descriptor
B
13
Bit 13 Descriptor
F
29
Bit 29 Descriptor
B
14
Bit 14 Descriptor
F
30
Bit 30 Descriptor
B
15
Bit 15 Descriptor
F
31
Bit 31 Descriptor
B
16
Bit 16 Descriptor
F
32
Bit 32 Descriptor
B
LOCATION 86 – WIEGAND FORMAT 4 (BIT DESCRIPTOR 33 - 64)
0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit
1
Bit 33 Descriptor
B
17
Bit 49 Descriptor
E
2
Bit 34 Descriptor
B
18
Bit 50 Descriptor
E
3
Bit 35 Descriptor
B
19
Bit 51 Descriptor
E
4
Bit 36 Descriptor
B
20
Bit 52 Descriptor
E
5
Bit 37 Descriptor
D
21
Bit 53 Descriptor
E
6
Bit 38 Descriptor
E
22
Bit 54 Descriptor
E
7
Bit 39 Descriptor
E
23
Bit 55 Descriptor
E
8
Bit 40 Descriptor
E
24
Bit 56 Descriptor
E
9
Bit 41 Descriptor
E
25
Bit 57 Descriptor
E
10
Bit 42 Descriptor
E
26
Bit 58 Descriptor
E
11
Bit 43 Descriptor
E
27
Bit 59 Descriptor
E
12
Bit 44 Descriptor
E
28
Bit 60 Descriptor
E
13
Bit 45 Descriptor
E
29
Bit 61 Descriptor
E
14
Bit 46 Descriptor
E
30
Bit 62 Descriptor
E
15
Bit 47 Descriptor
E
31
Bit 63 Descriptor
E
16
Bit 48 Descriptor
E
32
Bit 64 Descriptor
E
LOCATION 87 – WIEGAND FORMAT 4(PARITY TYPE 1)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 1
1
LOCATION 88 – WIEGAND FORMAT 4 (PARITY MASK 1)
1
Parity Mask 1
--------
5
Parity Mask 5
---45678
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
123456--
7
Parity Mask 7
--------
4
Parity Mask 4
12345678
8
Parity Mask 8
--------
LOCATION 89 – WIEGAND FORMAT 4 (PARITY TYPE 2)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 2
2
LOCATION 90 – WIEGAND FORMAT 4 (PARITY MASK 2)
1
Parity Mask 1
12345678
5
Parity Mask 5
--------
2
Parity Mask 2
12345678
6
Parity Mask 6
--------
3
Parity Mask 3
-----678
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 91 – WIEGAND FORMAT 4 (PARITY TYPE 3)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 3
0
LOCATION 92 – WIEGAND FORMAT 4 (PARITY MASK 3)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 93 – WIEGAND FORMAT 4 (PARITY TYPE 4)
1
Parity Type 4
0
LOCATION 94 – WIEGAND FORMAT 4 (PARITY MASK 4)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
NX-1710E Single Door Control
30
LOCATION 95 – WIEGAND FORMAT 4 (PARITY TYPE 5)
1
Parity Type 5
0
LOCATION 96 – WIEGAND FORMAT 4 (PARITY MASK 5)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
WEIGAND FORMAT 5
LOCATION 97 – WIEGAND FORMAT 5 (DIGITS & BITS) (DECIMAL DATA)
DESCRIPTION
DEFAULT
DATA
1
Number of Digits in Facility Code
6
2
Number of Digits in Badge Number
6
3
Number of Bits in Facility Code
19
4
Number of Bits in Badge Number
19
5
Total Number of Bits in Complete Weigand
Format (including parity bits)
40
LOCATION 98 – WIEGAND FORMAT 5 (BIT DESCRIPTOR 1 - 32) HEX DATA
0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit
SEG
DESCRIPTION
DEFAULT
DATA
SEG
DESCRIPTION
DEFAULT
DATA
1
Bit 1 Descriptor
D
17
Bit 17 Descriptor
F
2
Bit 2 Descriptor
F
18
Bit 18 Descriptor
F
3
Bit 3 Descriptor
F
19
Bit 19 Descriptor
F
4
Bit 4 Descriptor
F
20
Bit 20 Descriptor
F
5
Bit 5 Descriptor
F
21
Bit 21 Descriptor
B
6
Bit 6 Descriptor
F
22
Bit 22 Descriptor
B
7
Bit 7 Descriptor
F
23
Bit 23 Descriptor
B
8
Bit 8 Descriptor
F
24
Bit 24 Descriptor
B
9
Bit 9 Descriptor
F
25
Bit 25 Descriptor
B
10
Bit 10 Descriptor
F
26
Bit 26 Descriptor
B
11
Bit 11 Descriptor
F
27
Bit 27 Descriptor
B
12
Bit 12 Descriptor
F
28
Bit 28 Descriptor
B
13
Bit 13 Descriptor
F
29
Bit 29 Descriptor
B
14
Bit 14 Descriptor
F
30
Bit 30 Descriptor
B
15
Bit 15 Descriptor
F
31
Bit 31 Descriptor
B
16
Bit 16 Descriptor
F
32
Bit 32 Descriptor
B
LOCATION 99 – WIEGAND FORMAT 5 (BIT DESCRIPTOR 33 - 64)
0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit
1
Bit 33 Descriptor
B
17
Bit 49 Descriptor
E
2
Bit 34 Descriptor
B
18
Bit 50 Descriptor
E
3
Bit 35 Descriptor
B
19
Bit 51 Descriptor
E
4
Bit 36 Descriptor
B
20
Bit 52 Descriptor
E
5
Bit 37 Descriptor
B
21
Bit 53 Descriptor
E
6
Bit 38 Descriptor
B
22
Bit 54 Descriptor
E
7
Bit 39 Descriptor
B
23
Bit 55 Descriptor
E
8
Bit 40 Descriptor
D
24
Bit 56 Descriptor
E
9
Bit 41 Descriptor
E
25
Bit 57 Descriptor
E
10
Bit 42 Descriptor
E
26
Bit 58 Descriptor
E
11
Bit 43 Descriptor
E
27
Bit 59 Descriptor
E
12
Bit 44 Descriptor
E
28
Bit 60 Descriptor
E
13
Bit 45 Descriptor
E
29
Bit 61 Descriptor
E
14
Bit 46 Descriptor
E
30
Bit 62 Descriptor
E
15
Bit 47 Descriptor
E
31
Bit 63 Descriptor
E
16
Bit 48 Descriptor
E
32
Bit 64 Descriptor
E
LOCATION 100 – WIEGAND FORMAT 5 (PARITY TYPE 1)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 1
1
LOCATION 101 – WIEGAND FORMAT 5 (PARITY MASK 1)
1
Parity Mask 1
12345678
5
Parity Mask 5
12345678
2
Parity Mask 2
12345678
6
Parity Mask 6
--------
3
Parity Mask 3
12345678
7
Parity Mask 7
--------
4
Parity Mask 4
12345678
8
Parity Mask 8
--------
LOCATION 102 – WIEGAND FORMAT 5 (PARITY TYPE 2)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 2
2
NX-1710E Single Door Control
31
SEG
DESCRIPTION
DEFAULT
DATA
SEG
DESCRIPTION
DEFAULT
DATA
LOCATION 103 – WIEGAND FORMAT 5 (PARITY MASK 2)
1
Parity Mask 1
12345678
5
Parity Mask 5
--------
2
Parity Mask 2
12345678
6
Parity Mask 6
--------
3
Parity Mask 3
----5678
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 104 – WIEGAND FORMAT 5 (PARITY TYPE 3)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 3
0
LOCATION 105 – WIEGAND FORMAT 5 (PARITY MASK 3)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 106 – WIEGAND FORMAT 5 (PARITY TYPE 4)
1
Parity Type 4
0
LOCATION 107 – WIEGAND FORMAT 5 (PARITY MASK 4)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 108 – WIEGAND FORMAT 5 (PARITY TYPE 5)
1
Parity Type 5
0
LOCATION 109 – WIEGAND FORMAT 5 (PARITY MASK 5)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
WEIGAND FORMAT 6
LOCATION 110 – WIEGAND FORMAT 6 (DIGITS & BITS) (DECIMAL DATA)
DESCRIPTION
DEFAULT
DATA
1
Number of Digits in Facility Code
0
2
Number of Digits in Badge Number
11
3
Number of Bits in Facility Code
0
4
Number of Bits in Badge Number
38
5
Total Number of Bits in Complete Weigand
Format (including parity bits)
40
LOCATION 111 – WIEGAND FORMAT 6 (BIT DESCRIPTOR 1 - 32) HEX DATA
0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit
SEG
DESCRIPTION
DEFAULT
DATA
SEG
DESCRIPTION
DEFAULT
DATA
1
Bit 1 Descriptor
D
17
Bit 17 Descriptor
B
2
Bit 2 Descriptor
B
18
Bit 18 Descriptor
B
3
Bit 3 Descriptor
B
19
Bit 19 Descriptor
B
4
Bit 4 Descriptor
B
20
Bit 20 Descriptor
B
5
Bit 5 Descriptor
B
21
Bit 21 Descriptor
B
6
Bit 6 Descriptor
B
22
Bit 22 Descriptor
B
7
Bit 7 Descriptor
B
23
Bit 23 Descriptor
B
8
Bit 8 Descriptor
B
24
Bit 24 Descriptor
B
9
Bit 9 Descriptor
B
25
Bit 25 Descriptor
B
10
Bit 10 Descriptor
B
26
Bit 26 Descriptor
B
11
Bit 11 Descriptor
B
27
Bit 27 Descriptor
B
12
Bit 12 Descriptor
B
28
Bit 28 Descriptor
B
13
Bit 13 Descriptor
B
29
Bit 29 Descriptor
B
14
Bit 14 Descriptor
B
30
Bit 30 Descriptor
B
15
Bit 15 Descriptor
B
31
Bit 31 Descriptor
B
16
Bit 16 Descriptor
B
32
Bit 32 Descriptor
B
NX-1710E Single Door Control
32
LOCATION 112 – WIEGAND FORMAT 6 (BIT DESCRIPTOR 33 - 64)
0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit
SEG
DESCRIPTION
DEFAULT
DATA
SEG
DESCRIPTION
DEFAULT
DATA
1
Bit 33 Descriptor
B
17
Bit 49 Descriptor
E
2
Bit 34 Descriptor
B
18
Bit 50 Descriptor
E
3
Bit 35 Descriptor
B
19
Bit 51 Descriptor
E
4
Bit 36 Descriptor
B
20
Bit 52 Descriptor
E
5
Bit 37 Descriptor
B
21
Bit 53 Descriptor
E
6
Bit 38 Descriptor
B
22
Bit 54 Descriptor
E
7
Bit 39 Descriptor
B
23
Bit 55 Descriptor
E
8
Bit 40 Descriptor
D
24
Bit 56 Descriptor
E
9
Bit 41 Descriptor
E
25
Bit 57 Descriptor
E
10
Bit 42 Descriptor
E
26
Bit 58 Descriptor
E
11
Bit 43 Descriptor
E
27
Bit 59 Descriptor
E
12
Bit 44 Descriptor
E
28
Bit 60 Descriptor
E
13
Bit 45 Descriptor
E
29
Bit 61 Descriptor
E
14
Bit 46 Descriptor
E
30
Bit 62 Descriptor
E
15
Bit 47 Descriptor
E
31
Bit 63 Descriptor
E
16
Bit 48 Descriptor
E
32
Bit 64 Descriptor
E
LOCATION 113 – WIEGAND FORMAT 6(PARITY TYPE 1)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 1
1
LOCATION 114 – WIEGAND FORMAT 6 (PARITY MASK 1)
1
Parity Mask 1
12345678
5
Parity Mask 5
12345678
2
Parity Mask 2
12345678
6
Parity Mask 6
--------
3
Parity Mask 3
12345678
7
Parity Mask 7
--------
4
Parity Mask 4
12345678
8
Parity Mask 8
--------
LOCATION 115 – WIEGAND FORMAT 6 (PARITY TYPE 2)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 2
2
LOCATION 116 – WIEGAND FORMAT 6 (PARITY MASK 2)
1
Parity Mask 1
12345678
5
Parity Mask 5
--------
2
Parity Mask 2
12345678
6
Parity Mask 6
--------
3
Parity Mask 3
----5678
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 117 – WIEGAND FORMAT 6 (PARITY TYPE 3)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 3
0
LOCATION 118 – WIEGAND FORMAT 6 (PARITY MASK 3)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 119 – WIEGAND FORMAT 6 (PARITY TYPE 4)
1
Parity Type 4
0
LOCATION 120 – WIEGAND FORMAT 6 (PARITY MASK 4)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 121 – WIEGAND FORMAT 6 (PARITY TYPE 5)
1
Parity Type 5
0
LOCATION 122 – WIEGAND FORMAT 6 (PARITY MASK 5)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
WEIGAND FORMAT 7
LOCATION 123 – WIEGAND FORMAT 7 (DIGITS & BITS) (DECIMAL DATA)
DESCRIPTION
DEFAULT
DATA
1
Number of Digits in Facility Code
0
2
Number of Digits in Badge Number
0
3
Number of Bits in Facility Code
0
4
Number of Bits in Badge Number
0
5
Total Number of Bits in Complete Weigand
Format (including parity bits)
0
NX-1710E Single Door Control
33
LOCATION 124 – WIEGAND FORMAT 7 (BIT DESCRIPTOR 1 - 32) HEX DATA
0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit
SEG
DESCRIPTION
DEFAULT
DATA
SEG
DESCRIPTION
DEFAULT
DATA
1
Bit 1 Descriptor
E
17
Bit 17 Descriptor
E
2
Bit 2 Descriptor
E
18
Bit 18 Descriptor
E
3
Bit 3 Descriptor
E
19
Bit 19 Descriptor
E
4
Bit 4 Descriptor
E
20
Bit 20 Descriptor
E
5
Bit 5 Descriptor
E
21
Bit 21 Descriptor
E
6
Bit 6 Descriptor
E
22
Bit 22 Descriptor
E
7
Bit 7 Descriptor
E
23
Bit 23 Descriptor
E
8
Bit 8 Descriptor
E
24
Bit 24 Descriptor
E
9
Bit 9 Descriptor
E
25
Bit 25 Descriptor
E
10
Bit 10 Descriptor
E
26
Bit 26 Descriptor
E
11
Bit 11 Descriptor
E
27
Bit 27 Descriptor
E
12
Bit 12 Descriptor
E
28
Bit 28 Descriptor
E
13
Bit 13 Descriptor
E
29
Bit 29 Descriptor
E
14
Bit 14 Descriptor
E
30
Bit 30 Descriptor
E
15
Bit 15 Descriptor
E
31
Bit 31 Descriptor
E
16
Bit 16 Descriptor
E
32
Bit 32 Descriptor
E
LOCATION 125 – WIEGAND FORMAT 7 (BIT DESCRIPTOR 33 - 64)
0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit
1
Bit 33 Descriptor
E
17
Bit 49 Descriptor
E
2
Bit 34 Descriptor
E
18
Bit 50 Descriptor
E
3
Bit 35 Descriptor
E
19
Bit 51 Descriptor
E
4
Bit 36 Descriptor
E
20
Bit 52 Descriptor
E
5
Bit 37 Descriptor
E
21
Bit 53 Descriptor
E
6
Bit 38 Descriptor
E
22
Bit 54 Descriptor
E
7
Bit 39 Descriptor
E
23
Bit 55 Descriptor
E
8
Bit 40 Descriptor
E
24
Bit 56 Descriptor
E
9
Bit 41 Descriptor
E
25
Bit 57 Descriptor
E
10
Bit 42 Descriptor
E
26
Bit 58 Descriptor
E
11
Bit 43 Descriptor
E
27
Bit 59 Descriptor
E
12
Bit 44 Descriptor
E
28
Bit 60 Descriptor
E
13
Bit 45 Descriptor
E
29
Bit 61 Descriptor
E
14
Bit 46 Descriptor
E
30
Bit 62 Descriptor
E
15
Bit 47 Descriptor
E
31
Bit 63 Descriptor
E
16
Bit 48 Descriptor
E
32
Bit 64 Descriptor
E
LOCATION 126 – WIEGAND FORMAT 7 (PARITY TYPE 1)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 1
0
LOCATION 127 – WIEGAND FORMAT 7 (PARITY MASK 1)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 128 – WIEGAND FORMAT 7 (PARITY TYPE 2)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 2
0
LOCATION 129 – WIEGAND FORMAT 7 (PARITY MASK 2)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 130 – WIEGAND FORMAT 7 (PARITY TYPE 3)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 3
0
LOCATION 131 – WIEGAND FORMAT 7 (PARITY MASK 3)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 132 – WIEGAND FORMAT 7 (PARITY TYPE 4)
1
Parity Type 4
0
LOCATION 133 – WIEGAND FORMAT 7 (PARITY MASK 4)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
NX-1710E Single Door Control
34
LOCATION 134 – WIEGAND FORMAT 7 (PARITY TYPE 5)
1
Parity Type 5
0
LOCATION 135 – WIEGAND FORMAT 7 (PARITY MASK 5)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
WEIGAND FORMAT 8
LOCATION 136 – WIEGAND FORMAT 8 (DIGITS & BITS) (DECIMAL DATA)
DESCRIPTION
DEFAULT
DATA
1
Number of Digits in Facility Code
0
2
Number of Digits in Badge Number
0
3
Number of Bits in Facility Code
0
4
Number of Bits in Badge Number
0
5
Total Number of Bits in Complete Weigand
Format (including parity bits)
0
LOCATION 137 – WIEGAND FORMAT 8 (BIT DESCRIPTOR 1 - 32) HEX DATA
0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit
SEG
DESCRIPTION
DEFAULT
DATA
SEG
DESCRIPTION
DEFAULT
DATA
1
Bit 1 Descriptor
E
17
Bit 17 Descriptor
E
2
Bit 2 Descriptor
E
18
Bit 18 Descriptor
E
3
Bit 3 Descriptor
E
19
Bit 19 Descriptor
E
4
Bit 4 Descriptor
E
20
Bit 20 Descriptor
E
5
Bit 5 Descriptor
E
21
Bit 21 Descriptor
E
6
Bit 6 Descriptor
E
22
Bit 22 Descriptor
E
7
Bit 7 Descriptor
E
23
Bit 23 Descriptor
E
8
Bit 8 Descriptor
E
24
Bit 24 Descriptor
E
9
Bit 9 Descriptor
E
25
Bit 25 Descriptor
E
10
Bit 10 Descriptor
E
26
Bit 26 Descriptor
E
11
Bit 11 Descriptor
E
27
Bit 27 Descriptor
E
12
Bit 12 Descriptor
E
28
Bit 28 Descriptor
E
13
Bit 13 Descriptor
E
29
Bit 29 Descriptor
E
14
Bit 14 Descriptor
E
30
Bit 30 Descriptor
E
15
Bit 15 Descriptor
E
31
Bit 31 Descriptor
E
16
Bit 16 Descriptor
E
32
Bit 32 Descriptor
E
LOCATION 138 – WIEGAND FORMAT 8 (BIT DESCRIPTOR 33 - 64)
0 = Always Zero; 1 = Always One; B = Badge Number Bit; D = Parity Bit; E = End of Format; F = Facility Code Bit
1
Bit 33 Descriptor
E
17
Bit 49 Descriptor
E
2
Bit 34 Descriptor
E
18
Bit 50 Descriptor
E
3
Bit 35 Descriptor
E
19
Bit 51 Descriptor
E
4
Bit 36 Descriptor
E
20
Bit 52 Descriptor
E
5
Bit 37 Descriptor
E
21
Bit 53 Descriptor
E
6
Bit 38 Descriptor
E
22
Bit 54 Descriptor
E
7
Bit 39 Descriptor
E
23
Bit 55 Descriptor
E
8
Bit 40 Descriptor
E
24
Bit 56 Descriptor
E
9
Bit 41 Descriptor
E
25
Bit 57 Descriptor
E
10
Bit 42 Descriptor
E
26
Bit 58 Descriptor
E
11
Bit 43 Descriptor
E
27
Bit 59 Descriptor
E
12
Bit 44 Descriptor
E
28
Bit 60 Descriptor
E
13
Bit 45 Descriptor
E
29
Bit 61 Descriptor
E
14
Bit 46 Descriptor
E
30
Bit 62 Descriptor
E
15
Bit 47 Descriptor
E
31
Bit 63 Descriptor
E
16
Bit 48 Descriptor
E
32
Bit 64 Descriptor
E
LOCATION 139 – WIEGAND FORMAT 8 (PARITY TYPE 1)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 1
0
LOCATION 140 – WIEGAND FORMAT 8 (PARITY MASK 1)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 141 – WIEGAND FORMAT 8 (PARITY TYPE 2)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 2
0
NX-1710E Single Door Control
35
LOCATION 142 – WIEGAND FORMAT 8 (PARITY MASK 2)
SEG
DESCRIPTION
DEFAULT
DATA
SEG
DESCRIPTION
DEFAULT
DATA
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 143 – WIEGAND FORMAT 8 (PARITY TYPE 3)
0=No Parity; 1=Odd Parity; 2=Even Parity
1
Parity Type 3
0
LOCATION 144 – WIEGAND FORMAT 8 (PARITY MASK 3)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 145 – WIEGAND FORMAT 8 (PARITY TYPE 4)
1
Parity Type 4
0
LOCATION 146 – WIEGAND FORMAT 8 (PARITY MASK 4)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
LOCATION 147 – WIEGAND FORMAT 8 (PARITY TYPE 5)
1
Parity Type 5
0
LOCATION 148 – WIEGAND FORMAT 8 (PARITY MASK 5)
1
Parity Mask 1
--------
5
Parity Mask 5
--------
2
Parity Mask 2
--------
6
Parity Mask 6
--------
3
Parity Mask 3
--------
7
Parity Mask 7
--------
4
Parity Mask 4
--------
8
Parity Mask 8
--------
X.
ORDERING INFORMATION
PART #
DESCRIPTION
NX-1710E
Single Door Control Module
NX-1700E
Proximity Card Reader
NX-848E-KIT
NX-8E Control, NX-148E LED Keypad, 40VA Transformer
NX-848-KIT
NX-8 Control, NX-148E LED Keypad, 40VA Transformer
NX-648-KIT
NX-6 Control, NX-148E LED Keypad, 40VA Transformer
XI.
GLOSSARY
TERM
DESCRIPTION
Request To Exit (RTE)……
A zone can be programmed to monitor an open door. The RTE activates the
onboard relay and sends a message on the buss. (Refer to Loc 0, Pg 11)
Scan……………………….
To “present” or pass a card or FOB within sensing range of the card reader
module.
Single Beep………………..
An audible indicator (beep).
Single Scan…………
When a user card is scanned and held at the reader for 1 beep, the reader
will perform the functions as programmed in Loc 0, Pg 11
Triple Beep………………...
An audible indicator (beep, beep, beep).
Triple Scan………….
When a user card is scanned three times at the reader, the reader will
perform the functions as programmed in Location 0 & 1, Pgs 11 & 12
The NX-1710E module has not received any FCC approvals yet.
XIII.
UNDERWRITERS LABORATORIES INFORMATION
The NX-1710E module has not received any UL listings yet.
XIV.
SPECIFICATIONS
DIMENSIONS
Approx. 3.25"W x 6.00"L x 1"D
OPERATING POWER
12 VDC, Supplied by NX-4, NX-4V2, NX-6,
NX-6V2, NX-8, NX-8V2, NX-8E, or NX-320E
CURRENT DRAW
40mA Standby with Green LED
110mA Maximum
OPERATING TEMPERATURE
32 to 120 degrees F
SHIPPING WEIGHT
< 1 lb.
1420 N. MAIN STREET
GLADEWATER, TEXAS 75647
Main
800-727-2339
Technical Support
888-437-3287
Outside the US
903-845-6941
Sales & Literature
800-547-2556
Main Fax
903-845-6811
www.ge-security.com
Revision C (Feb 2005)