GE Profile PB970 Installation Instructions Manual
Read Online
Read the GE Profile PB970 Installation Instructions Manual online using the built-in PDF viewer.
Text of the manual
oIIVIPORTANT - Savethese
instructions
for
local
inspector's
use.
- iMPORTANT
- Observe
a,
governing
codes
and
ordinances.
e Note
to
mnstaller
- Be sure
to
leave
these
instructions
with
the
Consumer.
• Note
to
Consumer
- Keep these
instructions
for
future
reference.
• Skill
levet-
Installation
of this
appliance
requires
basic
mechanical
skilts.
• Completion
time
- 1 to
3 hours
• Proper
installation
is the
responsibility
of
the
installer.
• Product
failure
due to
improper
installation
is not
covered
under
the
Warranty.
-&WARNING
-
This
appliance must
be properly
grounded.
ANTI-TIP
DEVICE
-&WARNING
- Toreducetherisk
of tipping,
the
appliance
must
be secured
by
properly
installed
Anti-Tip
bracket
packed
with
this
appliance.
-&WARNING
-
• All ranges
can tip
• Injury
to persons
could
result
(_
• Install
Anti-Tip
bracket
packed
with
range
• See Installation
Instructions
If you
pull
the
range
out
and
away
from
the
wall
for
any
reason,
make
sure
the
Anti-Tip
bracket
is engaged
when
the
range
is pushed
back
against
the
wall.
FOR YOUR
SAFETY:
-&WARNING
-
Before
beginning
the
installation,
switch
power
off
at service
panel
and
lock
the
service
disconnecting
means
to
prevent
power
from
being
switched
on
accidentally.
When
the
service
disconnecting
means
cannot
be locked,
securely
fasten
a
prominent
warning
device,
such
as a tag, to
the
service
panel.
31-10652
02-07 JR
PREPARE TO INSTALL THE RANGE
FOR YOUR
SAFETY:
AJJ rough-in
and spacing
dimensions
must
be
met
for
safe
use of your
range.
To reduce
the
risk of burns
or fire
when
reaching
over
hot
surface
eJements,
cabinet
storage
space
above
the
cooktop
shouJd
be
avoided.
Jf cabinet
storage
space
is to
be
provided
above
the
cooktop,
the
risk can
be reduced
by instaJJing
a range
hood
that
protrudes
at Jeast 5"
beyond
the
front
of the
cabinets.
Cabinets
instaJJed
above
a cooktop
must
be no deeper
than
13:'
Be sure
your
appJiance
is propedy
instaJJed
and
grounded
by a quaJified
technician.
Make
sure
the cabinets
and wall
coverings
around
the range can w4thstand
the temperatures
(up to 200°F) generated
by the
range.
TOOLS
YOU
WiLL
NEED
Drill with
1/8" Bit
Safety
Glasses
Adjustable
Wrench
Tape
Measure
Pliers
Pencil
1/4" Nut Driver
Level
Phillips
Screwdriver
Flat-blade
Screwdriver
MATERIALS
YOU MAY
NEED
Tin Snips
Lag Bolts
Anchor
Sleeves
(For Anti-'13p Bracket Mounted
on Concrete Floors Only)
(UL Approved
40 AMP)
4-Wire Cord
OR
3-Wire
Cord
4' Long
4' Long
@
Squeeze
Connector
(For Conduit
Installations
Only)
PARTS INCLUDED
Anti-Tip
Bracket
Kit
171 REMOVE
SHIPPING
MATERIALS
Remove
packaging
materials,
Failure
to
remove
packaging
materials
could
result
in damage
to the
appliance.
PREPARE THE OPENING
See illustrations
for
all rough-in
and
spacing
dimensions.
The
range
may
be placed
with
0" clearance
(flush)
at the
back wall
and
side
walls
of
the
cabinet.
Acceptable
electrical
outlet
area.
*'15"
Min.
Orient
the electrical
L
i
receptacle
so the length
_231/2
v
is parallel
to the floor.
"_
NOTE:
Use a 4' power
cord
to prevent
interference.
Power
cords
41/2to
6' long
may
have
to be dressed
to allow
for
proper
installation.
L
AL
*0"_
*'30"
Min.
Mi
MINIMUM
DIMENSIONS
BETWEEN
COOKTOP,
WALLS
AND
ABOVE
THE COOKTOP:
* Make
sure
the
wall
covering,
countertop,
flooring
and
cabinets
around
the
range
can withstand
the
heat
(up to
200°F)
generated
by the
range.
**
Allow
30"
minimum
clearance
between
surface
units
and
bottom
of unprotected
wood
or metal
cabinet,
and
15"
minimum
between
countertop
and
adjacent
cabinet
bottom.
***
Recommended
spacing
to
heat-sensitive
surfaces.
do not use an extension
cord
with
this
appliance.
Remove
house
fuse
or open
circuit
breaker
before
beginning
installation.
This
appliance
must
be supplied
with
the
proper
voltage
and
frequency,
and connected
to an individual
properly
grounded
branch
circuit,
protected
by a circuit
breaker
or fuse
having
amperage
as specified
on the
rating
plate.
The
rating
plate
is located
on the
left
hand
side
of the
lower
oven
front
frame.
Location
of
i,
model
rating
plate
We recommend
you
have
the
electrical
wiring
and
hookup
of your
range
connected
by a
qualified
electrician.
After
installation,
have
the
electrician
show
you
where
your
main
range
disconnect
is located.
Check
with
your
local
utilities
for
electrical
codes
which
apply
in your
area.
Failure
to
wire
your
oven
according
to
governing
codes
could
result
in a hazardous
condition.
If there
are no local
codes,
your
range
must
be wired
and fused
to meet
the
requirements
of the
National
Electrical
Code,
ANSI/NFPA
No. 70-
Latest
Edition.
You can
get
a copy
by writing:
National
Fire
Protection
Association
Batterymarch
Park
Quincy,
MA
02269
Effective
January
1, 1996,
the
National
Electrical
Code
requires
that
new
construction
(not existing)
utilize
a 4-conductor
connection
to an electric
range.
When
installing
an electric
range
in new
construction,
follow
Steps
3 and 5 for 4-wire
connection.
You must
use
a 3-wire,
single-phase
A.C.
208Y/120
Volt
or 240/120
Volt,
60 hertz
electrical
system.
If the
electrical
service
provided
does
not
meet
the
above
specifications,
have
a
licensed
electrician
install
an approved
outlet.
Use only
a 3-conductor
or a 4-conductor
UL-listed
range
cord.
These
cords
may
be
provided
with
ring
terminals
on wire
and
a strain
relief
device.
A range
cord
rated
at 40 amps
with
125/250
minimum
volt
range
is required.
A 50 amp
range
cord
is not
recommended
but
if used,
it should
be marked
for
use with
nominal
13A" diameter
connection
openings.
Care
should
be taken
to center
the
cable
and
strain
relief
within
the
knockout
hole
to keep
the
edge
from
damaging
the
cable.
• Because
range
terminals
are not
accessible
after
range
is in position,
flexible
service
conduit
or cord
must
be used.
NOTE:
If conduit
is being
used,
go to Step
3D
and then
to Step
6 or 7.
• On some
models,
a filter
capacitor
may
be
connected
between
the
black
and white
leads
on the
junction
block.
ALL NEW
CONSTRUCTIONS,
MOBILE
HOMES
AND
INSTALLATIONS
WHERE
LOCAL CODES
DO NOT
ALLOW
GROUNDING
THROUGH
NEUTRAL,
REQUIRE
A 4-CONDUCTOR
UL-LISTED
RANGE
CORD.
4
POWER CORD AND
STRAIN
RELIEF INSTALLATION
[]
Remove
the terminal
block
cover
(on the
back
of the
range)
by removing
the
screw,
using
a 1/4"
nut
driver.
Do not
discard
the
screw.
[]
Screw
to
remove
terminal
block cover
Terminal
block cover
Remove
the
knockout
ring
(13X') located
on bracket
directly
below
the terminal
block.
To remove
the
knockout,
use
a
pair
of pliers
to
bend
the
knockout
ring
away
from
the
bracket
and
twist
until
ring
is removed.
NOTE: You only
need to remove
the
knockout
ring
for power
cord
installation.
Terminal
block
(appearance
may vary)
Knockout
ring
in bracket
Knockout
ring
removed
[]
For power
cord
installations
only
(see
the
next
step
if using
conduit),
assemble
the
strain
relief
in the
hole.
Insert
the
power
cord
through
the
strain
relief
and
tighten.
Allow
enough
slack
to easily
attach
the
cord
terminals
to the
terminal
block.
If tabs
are present
at the
end
of
the winged
strain
relief,
they
can
be
removed
for
better
fit.
NOTE:
Do not install
the
power
cord
without
a strain
relief.
The strain
relief
bracket
should
be installed
before
reinstalling
the
rear range
wiring
cover.
Terminal
../_
_
block
Power
cord
Bracket
Skip
to Step
4 or 5.
[]
For conduit
installations
only, purchase
a
squeeze
connector
matching
the diameter
of your
conduit
and assemble
it in the hole.
Insert
the
conduit
through
the squeeze
connector
and tighten.
Allow
enough
slack to
easily attach the wires
to the terminal
block.
NOTE:
Do not
install
the conduit
without
a
squeeze
connector.
The
squeeze
connector
should
be installed
before
reinstalling
the
rear range
wiring
cover.
Terminal
block
Squeeze
connector
Conduit
Skip
to Step
6 or 7.
Bracket
3-WIRE POWER CORD
INSTALLATION
WARNING:
The neutral
or ground
wire
of the power
cord must
be connected
to the neutral terminal
located
in the
center of the terminal
block. The power
leads must
be connected
to the lower
left
and the lower
right terminals
of the
terminal
block.
Remove
the
3 lower
terminal
screws
from
the terminal
block.
Insert
the
3
terminal
screws
through
each
power
cord
terminal
ring
and
into
the
lower
terminals
of the
terminal
block.
Be certain
that
the
center
wire
(white/neutral)
is connected
to the
center
lower
position
of the
terminal
block.
Tighten
screws
securely
into
the
terminal
block.
DO NOT remove
the
ground
strap
connection.
Ground
plate
Terminal
block
(appearance
may vary)
Neutral
terminal
Ground
strap
Power
cord
[]
Skip
to
Step
8 and
proceed
with
the
installation.
[]
4-WIRE POWER CORD
INSTALLATION
WARNING:
The neutralwire
of
the supply circuit must be connected to the
neutral terminal
located in the lower center
of the terminal
block. The power
leads must
be connected to the lower left and the lower
right terminals of the terminal
block. The 4th
grounding
lead must be connected to the
frame of the range with the ground plate
and the ground screw.
[]
Remove
the 3 lower
terminal
screws
from
the terminal
block.
Remove
the
ground
screw
and
ground
plate
and
retain
them.
[]
Cut and discard the ground strap. DO NOT
DISCARD ANY SCREWS.
[]
Insert the one ground
screw
into the power
cord ground
wire
terminal
ring, through
the
ground
plate and into the frame
of the range.
[]
Insert the 3 terminal
screws
(removed
earlier)
through
each power
cord terminal
ring and
into the lower terminals
of the terminal
block.
Be certain that the center wire
(white/neutral)
is connected
to the center lower
position
of
the terminal
block. Tighten
screws securely
into the terminal
block.
st rap
Terminal
or
block
Ground
strap
Neutral
terminal
After
Terminal
block
Ground
screw
Neutral
terminal
Ground
plate
(grounding
to
range)
[]
Skip to Step 8 and proceed with the installation.
6
Loosen the 3 lower
terminal
screws
from
the terminal
block.
Insert the center
bare
wire
(white/neutral)
tip through
the
bottom
center
terminal
block
opening.
On certain
models,
the wire
will
need to be inserted
through
the ground
strap
opening
and then
into the
bottom
center
block opening.
Insert
the two
side
bare wire
tips into the
lower
left and the lower
right
terminal
block
openings.
Tighten
the screws
until
the wire
is firmly
secured
(35 to 50 inch-lbs.).
Do not
over-tighten
the
screws
since
it could
damage
the wires.
NOTE:
ALUMINUM
WIRING:
Aluminum
building
wire
may
be used
but
it must
be rated
for
the
correct
amperage
and
voltage
to
make
connection.
Connect
wires
according
to this
Step
6 or Step
7 depending
on
number
of wires.
Terminal
block
if
Brack_
[]
Conduit
Wire
used,
location
and enclosure
of splices,
etc.,
must
conform
to
good
wiring
practices
and local
codes.
Skip
to
Step
8 and
proceed
with
the
installation.
[]
4-WIRE CONDUIT
INSTALLATION
[]
[]
Loosen
the three
lower
terminal
screws
from
the terminal
block. Remove
the ground
screw
and ground
plate and retain them.
Cut and discard
the
ground
strap.
DO NOT
DISCARD
ANY
SCREWS.
Before
__
bl°CkGround
str_
Insert the ground
bare wire tip between
the
range frame
and the ground
plate
(removed
earlier)
and secure it in place with
the ground
screw
(removed
earlier),
Insert the bare wire
(white/neutral)
tip through
the bottom
center
of the terminal
block opening.
Insert the two
side bare wire
tips into the lower
left and the
lower
right terminal
block openings.
Tighten
the screws
until
the wire
is firmly
secured
(35 to 50 inch-lbs.),
Do not
over-tighten
the
screws
since
it could
damage
the
wires,
round
strap
or
Neutral
_-_
terminal
After
Terminal
block
Wire tips
Ground
screw
Ground
plate
(grounding
to
range)
Bracket
Wire
used,
location
and
enclosure
of splices,
etc.,
must
conform
to
good
wiring
practices
and local
codes.
[]
Proceed
to Step 8.
INSTALL THE RANGE
[]
REPLACE THE WIRE COVER
Replace
the terminal
block
cover
on the
range
back by replacing
the screw
removed
earlier.
Make sure that
no wires
are pinched
between
the cover
and the
range
back.
Screw to
replace
terminal
block cover
ANTI-TIP
DEVICE INSTALLATION
An Anti-Tip
bracket
is supplied
with
instructions
for
installation
in a variety
of
locations.
The
instructions
include
all
necessary
information
to complete
the
installation.
Read the Safety
Instructions
and the
instructions
that
fit your
situation
before
beginning
installation.
Bracket...
Wall
plate
enter
wood
_Lt_'_ ....._°,
---__
Typical installation
of anti-tip bracket attachment
to wall
-4,WARNING:
• Range
must
be secured
by Anti-Tip
bracket
supplied.
• See instructions
to install (supplied
with
bracket).
• Unless
properly
installed,
the
range
could
be tipped
by stepping
or sitting
on the
door.
Injury
may
result
from
spilled
hot
liquids
or from
the
range
itself.
PREPARE TO LEVEL MODELS
[]
Measure
the
height
of your
countertop
at the
rear
of the
opening
(X).
X
[]
Adjust
two
rear
leveling
legs
so that
the
rear
of the
cooktop
(Y) is at the
same
height
as the
counter
(X).
[]
Slide
unit
into
place.
8
LEVEL THE RANGE
[]
[]
tnstall
the
oven
shelves
in the oven
and
position
the range where
it wilt be installed.
Check
for
levelness
by
placing
a spirit
levet or
^....._'_l|
a cup,
partially
filled
with
water,
on one of
the
oven
shelves.
If
using
a spirit
level,
take
two
readings--with
the
tevel
placed
diagonally
first
in one
direction
and then
the
other.
[]
The front
and
rear
leveling
legs can
be
adjusted
from
the
bottom.
L__
rLa°nV_
er
[]
Use an open-end
or adjustable
wrench
to adjust
the
leveling
legs
until
the
range
is level.
FINAL INSTALLATION
CHECKLIST
Check
to
make
sure
the
circuit
breaker
is
closed
(RESET)
or the
circuit
fuses
are
replaced.
Be sure
power
is in service
to the
building.
Check
to
be sure
that
all packing
materials
and
tape
have
been
removed.
This
will
include
tape
on metal
panel
under
control
knobs
(if applicable),
adhesive
tape,
wire
ties,
cardboard
and
protective
plastic.
Failure
to remove
these
materials
could
result
in damage
to the
appliance
once
the
appliance
has
been
turned
on and
surfaces
have
heated.
Check
to
make
sure
that
the
doors
are
parallel
to each
other
and that
both
operate
smoothly.
If they
do not,
see the
Owner's
Manual
for
proper
replacement.
Check
to
make
sure
that
the
rear
leveling
leg is fully
inserted
into
the
Anti-Tip
bracket
and
that
the
bracket
is securely
installed.
[]
OPERATION
CHECKLIST
Turn
on one of the
surface
units
to observe
that
the
element
glows
within
60 seconds.
Turn
the
unit
off when
glow
is detected.
If
the
glow
is not
detected
within
the
time
limit,
recheck
the
range
wiring
connections.
If change
is required,
retest
again.
If no
change
is required,
have
building
wiring
checked
for
proper
connections
and voltage.
Check
to
make
sure
the
Clock
(on models
so equipped)
display
is energized.
If a series
of
horizontal
red lines
appear
in the
display,
disconnect
power
immediately.
Recheck
the
range
wiring
connections.
If change
is
made
to connections,
retest
again,
If no
change
is required,
have
building
wiring
checked
for
proper
connections
and
voltage.
It is recommended
that
the
clock
be changed
if the
red lines
appear.
Be sure
all range
controls
are in the
OFF
position
before
leaving
the
range.