IEI Technology SEG-1 Installation Manual

Text of the manual

Secure Ethernet Gateway

SEG-1 and SEG-M for IEI Access Systems Installation Manual Section 1: Introduction SECURITY WARNING: New SEG's shipped after April 2008 will have Telnet setup option enabled by default. Enabling Telnet on the SEG allows you (the customer) to be able to configure the settings of the SEG via LAN without requiring the serial connection to the SEG via the “Gateway Config” RJ11 adapter. While enabling Telnet setup was done as a convenience to speed setup, it also opens a security hole in the SEG. It is recommended that when you are finished setting up the SEG, that you also enable the Telnet password option, so that a password is required to enter Telnet in the future. This Telnet password option is located in Setup menu option named “0 Server Configuration” and when you get to “Change telnet config password” enter Y and then enter a 4 digit password. You can also completely disable Telnet in the menu named “6 Security”. The SEG is a LAN/WAN (TCP/IP to serial) interface that enables existing or new IEI access systems to use the end user's network infrastructure and to be programmed and managed at any network PC running Hub Manager™ Professional software. The SEG requires Hub Manager™ Professional software version 5.0 or higher for static IP addressing and version 7.1 or higher for dynamic addressing. The access system data sent over the corporate network is 128-Bit so that user and door information cannot be "sniffed" and security compromised. The IP address assigned to the SEG may be either a static address assigned by authorized network administrator, or it may be a dynamic address assigned by a DHCP Server. IMPORTANT NOTE: To set up the SEG, installation technicians must have a technical knowledge of networks and networking in a PC environment. It is important to consult the end user's system administrator in order to resolve any networking issues that may occur. Ordering Information Model p/n Description SEG-1 0296005 IEI Secured Ethernet Gateway. Converts TCP/IP to serial data enabling IEI access systems to use a network to securely send and receive data; and to be programmed and managed from any network PC running Hub Manager Professional. Requires network connection. Wall mounts using separately provided hardware; requires separate 12VDC power [150 mA max], provided with modular cord for communication with access panel. SEG-M 0296006 IEI Secured Ethernet Gateway [Plug-in] Module. Converts TCP/IP to serial data enabling IEI access systems to use a network to securely send and receive data; and to be programmed and managed from any network PC running Hub Manager Professional. Requires network connection. Easily plugs into backplane which provides module power and communication with access panel. Document Number: 6066005, Rev 3.2 Page 1 of 34

Table of Contents

Section 1: Introduction.............................................................................................................................1 Section 2: Product Overview...................................................................................................................3 2.1 Product Specifications...................................................................................................................3 2.2 LED Status....................................................................................................................................3 Section 3: Hardware Installation..............................................................................................................4 3.1 SEG-1 Diagrams...........................................................................................................................4 3.2 Connection the SEG-1 to a HubMax or Hub MiniMax (RS-232)...................................................5 3.2.1 SEG-1 to HubMax/Hub MiniMax Connection Method 1........................................................5 3.2.2 SEG-1 to HubMax/Hub MiniMax Connection Method 2........................................................5 3.3 Connecting the SEG-1 to HC500P (RS-232)................................................................................6 3.3.1 SEG-1 to HC500P Connection Method 1..............................................................................6 3.3.2 SEG-1 to HC500P Connection Method 2..............................................................................6 3.4 Connecting Multiple HubMax/Hub MiniMax Networks..................................................................7 3.5 Connecting the SEG-1 to a prox.pad plus (RS-485).....................................................................8 3.5.1 SEG-1 to prox.pad plus Connection Method 1......................................................................8 3.5.2 SEG-1 to prox.pad plus Connection Method 2......................................................................8 3.6 Connecting Multiple prox.pad plus Networks................................................................................9 3.7 Connecting the SEG-1 to a Max 3 System (RS-485).................................................................10 3.8 Connecting the SEG-1 to a MiniMax 3 System (RS-485)...........................................................11 3.9 SEG-M Installation (Plug On Module).........................................................................................12 3.9.1 SEG-M Diagram...................................................................................................................12 3.9.2 SEG-M Connectors..............................................................................................................13 3.9.3 SEG-M LED Indicators.........................................................................................................13 3.9.4 Connecting the SEG-M to a HubMax System (RS-232)......................................................14 3.9.5 Connecting the SEG-M to a Hub MiniMax System (RS-232)..............................................14 3.9.6 Connecting the SEG-M to a Max 3 System (RS-485).........................................................15 3.9.7 Connecting the SEG-M to a MiniMax 3 System (RS-485)..................................................16 Section 4: SEG Configuration................................................................................................................17 4.1 Dynamic IP Address via DHCP server, IP Address in SEG can change....................................17 4.2 Dynamic IP Address, non-expiring lease....................................................................................20 4.3 Static IP Address.........................................................................................................................21 4.3.1 Setting a Static IP Address of a SEG through a serial connection (via PC com port)........21 4.3.2 Setting a Static IP Address of a SEG via LAN (through a Telnet connection) ...................22 4.3.3 SEG Setup Menu.................................................................................................................24 4.3.4 Configuring the IP Address in Hub Manager Professional..................................................27 4.4 SEG Parameters.........................................................................................................................27 4.4.1 IP Address............................................................................................................................27 4.4.2 IP Port..................................................................................................................................27 4.4.3 SEG Serial Net Number.......................................................................................................27 4.4.4 Security Key.........................................................................................................................27 4.4.5 Generate Random Security Key..........................................................................................28 4.4.6 Generate Default Security Key............................................................................................28 4.4.7 Set This Security Key into the SEG.....................................................................................28 4.5 Defaulting the SEG Settings.......................................................................................................28 4.5.1 Reset the Security Key in the SEG to all 0's .......................................................................28 4.5.2 Reset the Security Key in the SEG to all 0's .......................................................................29 4.5.3 Reset the Security Key in the PC to all 0's..........................................................................29 Section 5: Trouble Shooting..................................................................................................................30 Section 6: FCC Compliance Statement.................................................................................................33 Page 2 of 34 Document Number: 6066005, Rev 3.2

Section 2: Product Overview

2.1 Product Specifications The chart below contains the environmental and electrical specifications. Electrical Voltage 12VDC (9V Min; 20V Max) Current 150mA @ 9V; 100mA @ 20V Environmental Temperature 0° to 70 ° C (32° to 158° F) Humidity 0-95% RH Non-condensing Environment Indoor Only 2.2 LED Status The following diagram and chart describes the SEG LED operations. Data Send/Recieve (Top Left) Network Link (Top Right) Solid Idle Flashing Receiving data from Hub Manager Pro and it is being properly decrypted Solid Good Network Link Off No Network Link Status (Bottom Left) Diagnostics (Bottom Right) Solid (with top left blinking) 1x EEPROM Checksum Error 2x RAM Error 3x Network Controller Error 4x EEPROM Checksum Error 5x Duplicate IP Address on the Network Flashing (with top left blinking) 4x Faulty Network Connection 5x No DHCP Response Received 6x Software does not Match Hardware Flashing Alternately with Bottom Left Module is in Setup Mode Document Number: 6066005, Rev 3.2 Page 3 of 34

Section 3: Hardware Installation

The following section contains information about installing the SEG-1 and SEG-M hardware. 3.1 SEG-1 Diagrams Page 4 of 34 Document Number: 6066005, Rev 3.2

3.2 Connection the SEG-1 to a HubMax or Hub MiniMax (RS-232)

Two different methods can be used to connect Port A of the HubMax or HubMiniMax to the SEG-1: 1. Connect to the RS232 modular jack (front of SEG-1) 2. Connect to the RS232 terminals (rear of SEG-1) NOTE: If connection to SEG-1 is NOT located at the HubMax or HubMiniMax then the connection must be made via stranded/shielded cable. 3.2.1 SEG-1 to HubMax/Hub MiniMax Connection Method 1 The diagram below illustrates the method to connect the HubMax or HubMinimax to the RS232 port of the SEG-1 via its RS232 modular jack on the front of the unit. 3.2.2 SEG-1 to HubMax/Hub MiniMax Connection Method 2 The diagram below illustrates the method to connect the HubMax or HubMinimax to the RS232 port of the SEG-1via the terminal block at the rear of the unit. NOTE: The stranded shielded cable used in the diagram shows the connection to the SEG-1 across a distance. *THIS CHART PERTAINS TO THE CABLE RUN BETWEEN THE SEG-1 AND IEI ACCESS SYSTEMS Document Number: 6066005, Rev 3.2 Page 5 of 34