IMPORTANT SAFETY INSTRUCTIONS

When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: 1. Do not use this product near water, for example, near a bath tub, wash bowl, kitchen sink or laundry tub, in a wet basement or near a swimming pool. 2. Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning. 3. Do not use the telephone to report a gas leak in the vicinity of the leak. 4. Use only the power cord and batteries indicated in this manual. Do not dispose of batteries in a fire. They may explode. Check with local codes for possible special disposal instructions. 5. Plug the adaptor to the socket-outlet that near the equipment and shall be easily accessible. SAVE THESE INSTRUCTIONS –1– Declaration of Conformity Application of Council Directive(s) : Radio Equipment and Telecommunication Terminal Equipment Directive (1999/5/EC) - R&TTE Standard(s) to which Conformity is Declared: EMC: EN 55022:1998+A1: 2000, EN 610000-3-2: 2000, EN 61000-3.3: 1995 +A1:2001, EN 55024: 1998+A1: 2001, EN 50130-4: 1995/A1: 1998, EN 300220-3: 2000, EN 301489-3: 2002 Safety: EN 60950-1: 2001, EN 50371: 2002 Telephony: TBR 21: 1998 Manufacturer’s Name: Capital Prospect Limited Manufacturer’s Address: Room 3, 13/F, Block B, Veristrong Industrial Centre, 36 Au Pui Wan Street, Fo Tan, N.T., Hong Kong Type of Equipment: Home Smart Center Model No.: AM-001 Serial No.: Not Labelled Year of Manufacture: 2005 I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive (s) and Standard(s). Place: Hong Kong Joe Ng Project Manager Date: 21st July 2005

‘’This product meets the applicable Industry Canada technical

specifications.” Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications com- pany. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electri- cian, as appropriate. ‘’The Ringer Equivalence Number is an indication of the maximum number of terminals allowed to be connected to a telephone inter- face. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed five.’’ g) Should you experience trouble with this equipment, please contact Skylink Customer Support at 1-800-304-1187 for repair or warranty information. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved. h) Please follow instructions for repairing if any (e.g. battery replacement section); otherwise do not alternate or repair any parts of device except specified. i) Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information. j) NOTICE: If your home has specially wired alarm equipment connected to the telephone line, ensure the installation of this model AM-001 does not disable your alarm equipment. If you have questions about what will disable alarm equipment, consult your telephone company or a quali- fied installer. NOTICE: According to telephone company reports, AC electrical surges, typically resulting from lightning strikes, are very destructive to telephone equipment connected to AC power sources. To minimize damage from these types of surges, a surge arrestor is recommended. –51–

Installing the Console.................................................................................................7

Programming Passwords..........................................................................................9 Phone Number Programming..................................................................................10 Installing Door/Window Sensors.............................................................................12 Installing Motion Sensor...........................................................................................13 Operation..............................................................................................................................15 Alert mode...................................................................................................................15 Mute....................................................................................................................................16 System Status..............................................................................................................17 Arming The System.....................................................................................................17 Disarming the system...............................................................................................18 Disarming a triggered control panel.....................................................................19 Disarming under Duress..........................................................................................19 Panic...................................................................................................................................20 System Failure............................................................................................................20 Phone Line Failure............................................................................................20 Sensor Failure.....................................................................................................21 Low Battery...........................................................................................................21 Coummunication.............................................................................................................23 Receiving an emergency call..................................................................................23 Remote Operation by Telephone...........................................................................24 To access the control panel away from home......................................................24 Advanced Programming.................................................................................................26 Zone Dependent Setting – Beep / Alarm..............................................................26 Zone Dependent Setting – Auto Mute....................................................................29 Zone Dependent Setting – Alert Zone (Bypass zone).........................................30 Learn Keychain / Keypad Remotes........................................................................32 Erase Keychain / Keypad Remotes........................................................................33 Learn Sensors..............................................................................................................34 Sensor Location Selection Guide.............................................................................34 Erase Sensors...........................................................................................................36 Home Automation.............................................................................................................37 Learn Control Modules............................................................................................37 Erase Control Modules............................................................................................40 Event Trigger..............................................................................................................42 Trouble Shooting..............................................................................................................44 Accessories......................................................................................................................46 System Configuration.....................................................................................................49 FCC Information................................................................................................................50 CE........................................................................................................................................52 FCC Information Consumer Information: a) This equipment complies with Part 68 of the FCC rules and the require- ments adopted by the ACTA. On the bottom of this equipment is a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If requested, this number must be provided to the telephone company. b) An applicable certification jacks Universal Service Order Codes (USOC) for the equipment is provided (i.e., RJ11C) in the packaging with each piece of approved terminal equipment. c) A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. A compliant telephone cord and modular plug is provided with this product. It is designed to be connected to a compatible modular jack that is also compliant. See installation instructions for details. d) The REN is used to determine the number of devices that may be con- nected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total RENs, contact the local telephone company. [For products approved after July 23, 2001, the REN for this product is part of the product identifier that has the format US:AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label.] e) If this equipment AM-001 causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinu- ance of service may be required. But if advance notice isn’t practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. f) The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service. –50–

Congratulations on your purchase of a Skylink Home Smart Center. This is a

complete wireless system which not only functions as a security system, but also monitors your premises by giving you alert notification when the system is not armed. It is also a home automation center, which allows you to remotely control household appliances and lights, even when you are away from home. It can be controlled by dialing in from any touch tone phone, which makes it even more convenient and powerful. Additional accessories such as different kinds of sensors and controllers can be added to suit your specific needs. This user instructions will guide you through the whole setup procedure as well as all the programming instructions. Please follow the instructions closely, you should find it very easy to set up the system. In the package, you should find the following items: • One Control Panel • One Motion Sensor • Two Door / Window Sensors • One Keychain Remote Alert When Home (System Not Armed) Beep Beep Alarm Not Home (System Armed) Alarm Automation Communicator T M AM-001 PS-101 WD-101 4B-101 Master Password ____________________ Secondary Password ____________________ Duress Password ____________________ ZONE SENSOR 1 SENSOR 2 BEEP / ALARM AUTO MUTE EVENT TRIGGER ALERT Example Front Door Front Window Beep / Alarm Y / N Disabled / On / Off Y / N 1 2 3 4 5 Sensor locations and settings Phone number settings PHONE MEMORY PHONE NUMBER REDIAL COUNT REPEAT COUNT Example 321-123-4567 5 5 1 2 3 4 5 Keychain / Keypad Remotes settings KEYCHAIN / KEYPAD LOCATIONS OWNER (KEYCHAIN) / LOCATION (KEYPAD) Example Keychain Owner - John 6 7 8 9 0 Control Modules settings CONTROL MODULES LOCATIONS / APPLIANCES Example Family room lighting 6 7 8 9 0 SYSTEM CONFIGURATION –49–

One AC adapter

• One telephone cord • Batteries for all sensors - 1 PC 9V Alkaline Battery (PS-101) - 1 PC 12V Alkaline Battery Type 23A (4B-101 -installed) - 2 PCS 3V Lithium Battery CR-2032 (WD-101 -installed) • Four AAA backup batteries for Control Panel • Mounting hardware Basic installation involves the following procedures: 1. Install Control Panel AM-001 2. Program Passwords 3. Program Phone Numbers 4. Install Door / Window Sensors WD-101 5. Install Motion Sensor PS-101 9V Mounting Plate Ball-head joint Screws Pack Control Module SW-100 (US and Canada) - To turn home appliances / lights on / off - Max rating: 960W (Resistive) Control Module SW-101U (UK), SW-101F (French), SW-101G (German) (3 models for 3 countries) Emergency Dialer (AD-433S) - External dialer with user programmable voice message - Calls up to 9 phone numbers - One personal voice recording up to 40 seconds - Can be installed anywhere within 100 feet from the control panel, with a phone socket Swing door opener (DM-100) - Remotely open / close a swing door - Fits most interior doors ACCESSORIES 905-608-9223 AD-433 ® –48–

10. System Low Battery LED

11. Built-in Siren and Speaker 12. Antenna 13. Programming button 14. Buzzer Mode Selector 15. Phone Jack for external phone 16. Line Jack for telephone line 17. Adapter socket 18. Battery Compartment 19. Language Selector (only available for models with multiple languages) –6– 17 18 19 14 13 7 12 11 10 8 1 2 3 4 5 6 9 ACCESSORIES Audio Sensor (AS-101) - When audio level exceeds preset limit, it will trigger the alarm - Place beside smoke detector, CO detector, so when these detectors are triggered, the control panel will be triggered Remote Control (4B-101) - Additional keychain remotes for other family members - To arm, disarm or trigger the panic alarm with this remote Keypad Control (KP-434) - External keypad control - To arm, disarm or trigger the the panic alarm with this remote - Ideal mounting locations include upper floor, backdoor, or garage Wrist Watch Style Panic Remote (HW-434) - Activate the panic alarm instantly with this remote - Wear it as a watch - Splashproof design, can be worn during showering Panic Transmitter (PT-434) - Activate the panic alarm instantly with this remote - Wear it as a pendant - Splashproof design, can be worn during showering Audio Alarm (AA-433) - External Siren - Powered by AC adapter with backup battery ® AA-433 ® –47–

Installing the Console

You must first determine where the control panel will be located. Please follow the criteria below to select the ideal location for the control panel. - Place it within a few feet of an electrical outlet and phone jack - Place it where it is easily accessible by you and other users - Place it away from any doors or windows which could be accessed by non- intended users - Place it away from extreme temperature sources such as oven, stove and away from large metal objects which could affect the wireless performance After you have selected a location for the control panel, you are now ready to connect all the necessary wires and ready to power up the unit. 1. Plug in the AC adapter to a nearby electrical outlet and plug the other end to the socket labeled “DC 12V” on the back of the control Panel. You should hear 3 beeps and “System Phone Failure” indicating the phone line is not connected. PWR, ARM and PROG LEDs should be flashing, LO BATT LED should be on. 2. Remove the battery cover on the bottom of the control panel with a Phillips screw driver, and insert 4 AAA alkaline batteries into the battery holder (note the polarity). After inserting the batteries, the LO BATT LED should be off. 3. Connect the phone line from the telephone jack to the back of the control panel where it marks “LINE”. PWR will stay on and PROG LED will stop flashing. 4. [OPTIONAL] If you have another telephone that will be using the same telephone jack, you may connect this telephone to "PHONE" outlet of the the control panel by a phone cord. (not provided). 5. Rotate the antenna to the upright position to ensure the best signal reception. 4 3 1 –7– 2 Door/Window Sensor (WD-101) - Magnetic Contact Sensor - For all doors or windows - Batteries included Repeater (RP-434) - Extend the operation range between 2 wireless devices, such as any sensors and control panel - Doubles the operation range automatically between sensors and control panel Water Sensor (FS-101) - Alerts you when water is detected - Ideal for water detection in basement, under the sink, even bathroom Garage Door Monitor TM Sensor (GS-101) (Available in US and Canada) - Monitors your garage door - Alerts you when the garage door is left open Garage Door Monitor TM Sensor (GS-102) (Available outside US and Canada) - Monitors your garage door - Alerts you when the garage door is left open Indoor/Outdoor Motion Sensor (PS-101) - Monitors area in a 110 degree ARC and up to 40 feet away from the sensor ACCESSORIES Additional sensors and transmitters as well as add on accessories are available to work with your system. T M –46–

6. For models with multiple languages,

select the desired language based on the setting below. [ 1 ] - German [ 2 ] - Spanish [ 3 ] - French [ 4 ] - English Language selector INSTALLATION –8– After mounting the door sensor, it - Please ensure the magnet is aligned with doesn’t work anymore. the red marking on the transmitter. - If you are mounting the sensor on to a metal door or window, a spacer may be required to avoid magnetic interference caused by the metal door / window. - Make sure the sensor is within the operation range of the control panel by bringing it closer to the control panel. My motion sensor is not very The motion sensor is designed to detect the responsive, sometimes when I walk “First Motion”. First Motion means no motion by it, the control panel doesn’t respond, is detected within the past 20 seconds, but sometimes it does. and if a motion is then detected, that is the “First Motion”. So if you continue to walk in front of the motion sensor, it will only pick up the first motion. Unless you wait for 20 seconds, then walk again, the control panel will respond. Otherwise, the control will only respond to the first motion. TROUBLE SHOOTING –45– When a sensor is triggered, the - Make sure the battery in the sensor is control panel doesn’t respond at all, installed properly, pay attention to the what is the problem? polarity. - Make sure the sensor is learned to the control panel. Follow instructions on page 34 on how to learn a sensor. - You may try to bring the sensor closer to the control panel, ensure it is not out of the operation range. My motion sensor sometimes gets Ensure the motion sensor is not facing triggered by itself, how can I prevent direct sunlight, nor any A/C or furnace that? vents. You may also reduce the sensitivity to low. If your motion sensor is located outdoors, you may want to relocate it. Sensors

3 beeps for valid

password to password. 1 long programming mode beep for invalid password. [1] - Master password [2] - Secondary password [3] - Duress password Select any 4-digit pass- word, each digit can be from 0 to 9 Enter the new password 3 beeps if new pass- again for confirmation word is accepted. You will hear [Password Accepted] Programming Passwords Master Password can be used for programming, arming, disarming the system, and telephone access. The default Master Password is [1234]. Secondary Password can be used for arming, disarming the system, and telephone access. Secondary Password cannot be used for programming. The default Secondary Password is [0000]. Duress Password is used when you are forcibly compelled to disarm the control panel. Entering the duress password will stop the siren from sounding but the control panel will silently call the emergency phone numbers for help. The default Duress Password is [3838]. You should definitely change this password and let all the users know this password. Changing Passwords It is strongly recommended to change all 3 passwords when you first set up the system. In order to change the password, follow the procedures below. INSTALLATION [PROG] [MPIN] [2] [1] or [2] or [3] [new 4-digit password] [new 4-digit password] Enter Programming mode Select password programming Select which password to change Enter new password Enter new password to confirm 1 2 3 4 5 –9– Step Keys Function Description Note Questions Solutions Why I can’t arm my system? Make sure none of the sensors are triggered. You can check this by the zone LEDs, none of them should blink. I cannot arm the system even when no You need to disarm the system again by sensor is triggered, and the ARM LED either entering the password or disarm by is off. keychain remote. Although the ARM LED is off, but the system is not completely disarmed after an alarm was triggered. Refer to page 19 on how to completely disarm a control panel after an alarm has been triggered. Why the ARM LED keeps flashing? That means you have not programmed any emergency phone numbers. For instructions on how to program emergency phone numbers, please see page 10. How do I exit programming mode You can press the programming button on when I’m in the middle of it? the side of the unit to quit programming anytime. When a sensor is triggered, the alarm You have programmed that sensor in alarm sounds instantly even it is not armed, mode, instead of beep mode. Please refer why is that? to page 26 for instructions of how to program it back to beep mode. When the alarm is triggered, why The control panel will stop calling when it the control panel won’t call all the is disarmed by any one of the recipients. programmed phone numbers? It Disarm can also be done locally thru the always stops before calling the keypad on the control panel by entering a last number. valid password. Why the control panel doesn’t beep You have placed the buzzer mode selector when a sensor is triggered, while on the side of the control panel to “II”, this only the zone LED flashes? will disable the beeping. Placing it to “I” will enable the beeping. The control panel is in armed mode, If the triggered sensor is programmed in the why activating a sensor will not cause Alert Zone (Bypass Zone), alarm will not an alarm, or call any emergency phone sound, and emergency call will not be made number? if this sensor is triggered. The control panel will only respond when it is disarmed, in alert mode. TROUBLE SHOOTING Control Panel –44–

Phone Number Programming

You can program up to 5 Emergency Phone Numbers. When the system is in panic, the control panel will call these phone numbers and announce its status. The following will need to be programmed: - Phone memory (from 1 to 5), this is where the phone numbers will be stored - Phone number, up to 29 digits. - Redial count, this is how many times that phone number will be called, from 1 to 9 times. - Repeat count, this is how many times the emergency message will be repeated, from 1 to 9 times. **Note: You may enter a 3-second pause between digits by pressing [Mute] if needed. You may also enter consecutive multiple pause periods. For example, you may enter a phone number: (123)-456-7890 [Mute] 1234. After the phone number (123)-456-7890 is dialed, it will wait for 3 seconds, then dial 1234, which can be a password to a paging system, or an access code for a phone dialing system. –10– INSTALLATION You will hear [Enter Redial]. You will hear [Enter Repeat]. 3 beeps for valid password. 1 long beep for invalid password. During emergency, phone memory 1 will be called first, then phone memory 2, 3, 4, and 5. So phone memory 1 has higher priority. You will hear [Enter phone memory]. You will hear [Phone Accepted] indicating the phone number and its settings have been programmed successfully. Repeat is the number of times that voice emergency message will be played, from 1 to 9 times. It is recommended to set up the repeat time to 5 or more. Redial is the number of times that phone number will be called. Each phone number can have a different redial count, from 1 to 9 times. Phone number can be up to 29 digits.** Enter master password to programming mode [1] to [9] + [Arm] [1] to [9] + [Arm] [1] [1] to [5] [PROG] [MPIN] [Phone number] + [Arm] Enter Repeat count Enter Redial count Enter Programming mode Select phone number programming Enter phone number Enter phone memory 1 2 3 4 5 6 Step Keys Function Description Note HOME AUTOMATION DISABLE EVENT TRIGGER ENABLE EVENT TRIGGER This row : Buttons to Disable Event Tigger Zone LED : Off This row : Buttons to Enable Event Trigger Zone LED : 1) On (Event Trigger On) 2) Flash (Event Trigger Off) ® Press once will enable “Event Trigger On”, press again will enable “Event Trigger Off”. This row of buttons operates in toggle manner, between event trigger on and event trigger off. –43– Zone 1 Button [1] Zone 2 Zone 3 Zone 4 Zone 5 Button [2] Button [3] Button [4] Button [5] Button [6] Button [7] Button [8] Button [9] Button [0]

- It’s not recommended to program 911, fire station or any emergency services

phone numbers into any of the phone memories without their approvals. - Ensure to program a valid phone number and write down the programmed phone number on the System Setting Information provide on the back of this user's instructions. - You may quit programming by pressing [PROG] button at any time. - If no phone number is programmed, the ARM LED will continue to flash. Testing Phone Numbers: After you have programmed all the phone numbers, you should verify you have programmed the phone numbers correctly. This can be done by triggering the alarm silently by entering the duress password, so it dials to the programmed phone numbers without sounding the alarm. Note: You must inform the recipients of the programmed phone numbers, so they know what to expect when they receive the phone call from the control panel during an emergency. These recipients should know the password to your control panel if you expect them to have remote access of your control panel. For more informa- tion regarding receiving the emergency call, please refer to page 23. 1. Press [Arm], you should hear beeping from the control panel. 2. Press [3838]. Beeping will stop, and the control panel will start to dial the first number. 3. The called party should receive the call. Pick up the call and say “Hello”, an emergency message “System Panic” will be played. If the programmed phone doesn’t ring, ensure the phone number is programmed correctly, or reprogram this phone number again. 4. After the emergency message has been played for several times (depending on how many times it was programmed), the called party will hear “Enter Password”. 5. Enter either the master password or secondary password. If the correct password is accepted, you will hear “Password Accepted”, otherwise, you will hear “Password Failure”. 6. Press [0][#] on the telephone to hang up. 7. The control panel will start to dial the next programmed phone number. Note: - Refer to page 23 [Receiving the Emergency Call] for more info on how to react to an emergency call. - The password is treated as a confirmation of the emergency message. Once a valid password is entered, the control panel will not call that number again, it will proceed to the next number. - If any one of the called parties disarms the control panel, the control panel will not continue to dial the remaining phone numbers. - After calling all the programmed phone numbers, the control panel will be back to the previous operation mode. INSTALLATION –11– HOME AUTOMATION Event Trigger You can control up to 5 different devices not only manually, but also automatically. It is called Event Trigger. That means when a sensor is triggered, the control panel will transmit a signal to activate the designated control module. Applications include: - Lights on when you open the front door (walking into a room, lights on automatically), this is called "Event Trigger on". - Lights off when you open a door. (walk away from a room, turns lights off), this is called "Event Triggered off". Event trigger is only applicable to the sensor(s) and control module in the same zone. For example, you can program control module 1 to be on or off when zone 1 sensor(s) is triggered. You can also program control module 2 to be on / off when zone 2 sensor(s) is triggered. Factory Default: This feature is disabled for all zones at the factory. To change the event trigger setting follow the instructions below. Event Trigger On Event Trigger Off 1 2 3 4 [PROG] [MPIN] Enter Program- ming mode Enter master password to programming mode 3 beeps for valid password. 1 long beep for invalid password. [7] Select Event Trigger After [7] is entered, some zone LEDs will be off, on or flash. This indicates the setting of event trigger. Disable Event Trigger: [1] to [5] Enable Event Trigger: [6] to [0]. Select which zone you would like to enable / disable event trigger. Refer to the diagram below to select the appropriate setting. If event trigger “ON” is enabled, that zone LED will be on. If event trigger “OFF” is enabled, that zone LED will flash. If it is disabled, the zone LED will be off. You are allowed to make multiple changes before terminating programming mode. [PROG] when finished. Terminate programming mode. PROG LED will be off. Step Keys Function Description Note –42–

Window / Door Sensor is used to monitor doors or windows that

open and close. When these doors / windows are open or closed, the sensors will transmit a signal to the control panel to notify the user. These sensors consist of 2 parts, one is the transmitter, the other is the magnet. Before installing the sensor, remove the battery isolator by pulling out the yellow tab. Once the isolator is removed, the control panel will announce the sensor's status, such as "Zone 1 Sensor 1 Triggered", and corresponding zone LED will flash and buzzer will beep. If the magnetic contact is closed, the beeping will stop. Note: - Both Window/Door Sensors have been programmed at the factory. They are Zone 1 Sensor 1 and Zone 2 Sensor 1. Trigger the sensor and listen to the announcement to determine which one is zone 1 and which is zone 2. Testing: After mounting the sensor, test the sensor by opening and closing the door or window. Open the door or window will result in the followng: 1. Voice announcement - Announce the triggered zone and sensor 2. Beeping - The number of beep represents the zone number 3. Zone LED flashing - Number of flash represents the sensor number. Mounting the Sensor The transmitters should be mounted on the door frame or window frame by double sided tape. The magnet should be mounted on the door or window by either double sided tape or screws. Make sure the magnet is aligned with the red marking on the transmitter. If the surface of the frame is flat enough, double- sided foam tape is sufficient, otherwise, it is recommended to screw the mounting plate to the frame, then apply double sided tape. After mounting the sensor, if the AAA+ logo is inverted, remove the front cover and rotate it so the AAA+ logo is in the upright position. INSTALLATION Installing Door / Window Sensors Transmitter Magnet Double-sided foam tape Mounting plate and screws (optional) Sensor Sensor Sensor Magnet Magnet "Red Marking" "Red Marking" Magnet on the left Magnet on the right HOME AUTOMATION Part 2 Erase communication from Control Panel to Control Module ZONE LED DESCRIPTION Off Zone is not occupied by any control module Flashes twice That means a remote has occupied that zone. THIS IS NOT A CONTROL MODULE, THEREFORE, SHOULD NOT BE ERASED. Flashes once That zone is occupied by a control module. You may select this zone to erase this control module. Flashes once, That means this zone is occupied by a remote AND a control module. then twice You may select this zone to erase the control module. ** Table F: Zone LED status for erasing control module. 1 2 Enter program- ming mode Enter master password to programming mode 3 beeps for valid password. 1 long beep for invalid password. To erase the memory of the control module Control module LED will flash rapidly indicating all the memory is erased. You may now release the learn button. Remove the control module from the electrical outlet Press and hold the learn button on the control module while plugging in the control module to an electrical outlet. Once the memory of the control module is erased, all of its memory is cleared. If you have other remotes / control panels controlling this control module, you need to re-program those remotes / control panels. Step Keys Function Description Note –41–

Undo the screw on the back of the motion sensor and

remove the battery cover. Connect a 9V alkaline battery to the battery connector. Please note the polarity. If you are planning to install the motion sensor outdoor, you should reduce the sensitivity by placing the jumper at location “2”. For indoor application, if you want to reduce the sensitivity, you can change the jumper setting to “2” as well. Note: - Try to mount the sensors as far away from the floor as possible to avoid damaging them. Mounting the sensors at a higher position will also result in better operating range. - Do not mount the sensor to the exterior of the door / window, always mount the sensor to the interior side of the door / window to avoid being damaged or stolen by non-intended users. INSTALLATION The motion sensor is most suitable for guarding a large area such as living room, family room, or bedroom. It can also be used to monitor a hallway or stairway. –13– 3. Single flash 1. Zone 1 Sensor 1 Triggered 2. Beep___Beep___ Beep___Beep___ ............ Installing Motion Sensor Sensitivity Caution: Depending on the environment, if you experience a false trigger when the motion sensor is placed outdoors, you should relocate it or even place it indoors. Wind blowing at a tree, or direct sunshine could cause a false trigger. Therefore, if the location at where the motion sensor is mounted could cause a false trigger, you should change the mounting location for such sensor. Jumper Location 1 High Sensitivity Jumper Location 2 Low Sensitivity HOME AUTOMATION Erase Control Modules To erase a control module from the control panel, it is similar to learning a control module, which involves 2 parts. 1. Erase the memory of the control panel 2. Erase the memory of the control module Part 1 Erase the memory of the Control Panel 1 2 3 [PROG] [MPIN] Enter Programming mode Enter master password to programming mode 3 beeps for valid password. 1 long beep for invalid password. [0] Select erase control module programming After [0] is entered, some zone LEDs will flash or stay off. The zone LEDs represent whether that zone is occupied by any control module. **See Table F Select the control module location you would like to erase Refer to the table below to select the control module location. After you have selected the remote location, you will hear 3 beeps and verbal confirmation [Device X Empty Memory], where X is the control module location you have selected. To erase an occupied control module, press [1] to [5]. To turn off a light with the control panel: 1. Press the device number button on the control panel, i.e. pressing 1 will turn off device 1, pressing 2 will turn off device 2. 2. You will hear [Device X Off], where X is the device number. 3. You will also see the PROG LED flashing, indicating the control panel is sending out the wireless signal to control the specific device. 4. If the receiver receives the signal, the control panel will announce [Device Off Accepted]. To turn on a light with the control panel: 1. Press the number below the device number that you would like to turn on, i.e. pressing 6 will turn on device 1, pressing 7 will turn on device 2. 2. You will hear [Device X On], where X is the device number. 3. You will also see the PROG LED flashing, indicating the control panel is sending out the wireless signal to control the specific device. 4. If the receiver receives the signal, the control panel will announce [Device On Accepted]. Operation Step Keys Function Description Note –40–

When installing the motion sensor, avoid placing it near heat or cold producing

devices (i.e. A/C or furnace vents, fans, ovens, space heaters, etc). Air movement, especially caused by changes in temperature may trigger the Motion Sensor and cause false alarms. Please carefully test your Motion Sensor so that it will only be triggered by wanted movement. You have now successfully installed and programmed the Control Panel and its sensors. Please follow the rest of the instructions for operations and advanced programming. –14– Testing Walk test should be performed after the motion sensor is mounted. Walk in the detected area, if motion is detected, a red light inside the sensor will glow. If the red light does not glow, motion has not been detected and you may need to re-position the sensor. Ensure you walk test all the locations that you would like the motion sensor to cover. Note: - Perform the walk test after you have inserted the battery for more than 1 minute. - Before performing the walk test, the sensor should not detect any motion. - After motion is detected once, the sensor will not be triggered unless no motion is detected for 20 seconds. Therefore, wait for at least 20 seconds during walk testing between 2 activations. INSTALLATION You may now close the battery cover and re-insert the screw. Mount the ball-head joint on the wall with screws provided. Slide the back of the sensor into the ball-head joint. The mounting angle can be adjusted. For outdoor monitoring, please refer to page 30 to program the motion sensor to Alert Zone. M 0 1 2 3 4 5 6 7 8 9 10 11 12 13 2 4 6 8 10 12 14 DETECTING AREA: (Unit = meter) 55° 22° 22° 12° SENSOR 27° 55° 1.2M 11° Part 2 Learn signal from Control Panel to Control Module HOME AUTOMATION Control Module [1] is represented by zone LED 1 ® CONTROL MODULE LOCATION 1 6 2 7 3 8 4 9 5 0 TRANSMIT BUTTON [X] 1 2 Enter Programming mode LED on the Control Module will flash indicating it is in learn mode. [6] to [0] Transmit an ON signal for the selected device from the Control Panel to the Control Module. Refer to the chart below to determine which button [6] to [0] to press. You should transmit the “ON” command for the selected device. After [X] is entered, you will hear [Device X On] indicating you have trans- mitted an ON signal for device X, where X is the Control Module Location. The LED on the Control Module should be off, indicating it has learned the signal, you may now release the learn button and the LED will stay on again. Press and hold the learn button on the Control Module until its LED starts to flash. Step Keys Function Description Note –39– This row : Buttons for Learning Control Module

- Each zone can program up to 2 sensors. There are 5 zones, so up to 10 sensors

can be programmed to the control panel. Please refer to page 34, "Sensor Location Selection Guide" for detail information. Alert Mode Examples Note: -For Door / Window sensor, alert notification (beeping and LED flashing) will continue until the sensor is in closed position, i.e. closing the window or door. -For Motion Sensor, the alert notification (beeping and LED flashing) will last for 15 seconds for every detected movement.–15– The Control Panel is always in one of the 2 operating modes: 1. Alert Mode - When the system is not armed (ARM LED off), it is in alert mode. 2. Alarm Mode - When the system is armed (ARM LED on), it is in alarm mode. The Control Panel will be in alert mode automatically if the system is not armed. Alert mode allows users inside the premises to know what sensor is triggered. It is intended to be used when someone stays inside the premises. In alert mode, the control panel will give you notification of the triggered sensor(s) by voice announcement, unique beeping and LED flashing. 1 Number of beeps Zone of the triggered sensor 2 Number of flashes of zone LED Sensor number of the triggered sensor 3 Voice announcement Tells you the zone and locations of the triggered sensor by human voice. Alert Mode 3. Double flash 1. Zone 3 Sensor 2 Triggered 2. Beep Beep Beep___ Beep Beep Beep___ 3. Single flash 1. Zone 1 Sensor 1 Triggered 2. Beep___Beep___ Beep___Beep ..... Zone 1 Sensor 1 door open Zone 3 Sensor 2 window open Part 1 Learn signal from Control Module to Control Panel HOME AUTOMATION ZONE LED DESCRIPTION Off Zone is not occupied by any control module Flashes once This zone is occupied by another control module. Programming another remote to this zone will overwrite the previous control module. Flashes twice This zone is occupied by a remote. You can still program a control module to this zone, and it will not overwrite the remote you have in this zone. Flashes once, This zone is occupied by a remote AND a control module. If you then twice program another control module to this zone, it will overwrite the previous control module, but not the remote. ** Table E: Zone LED status for learning control module. Activate the control module by pressing its learn button once quickly. 1 2 3 4 [PROG] [MPIN] Enter Program- ming mode Enter master password to programming mode 3 beeps for valid password. 1 long beep for invalid password. Select learn control module programming [1] to [5] After you have selected the control module location, that zone LED will be on. After [4] is entered, some zone LEDs will flash or stay off. The zone LEDs represent whether that zone is already occupied by another control module.**See Table E. Select control module location (Max. 5 control modules) Select the location [1], [2], [3], [4], or [5]. Send signal from control module to control panel. Once the signal is transmitted to the Control Panel, that signal will be stored. You will hear [Device X Accepted], where “X” is the control module location. [4] Step Keys Function Description Note –38–

When the alert beeping becomes undesired, you can terminate the beeping in 3

different ways: 1. Mute button - Manual mute by pressing the mute button Pressing the mute button will temporary disable the beeping for all the activated sensors. For example, if a window with a window sensor will be open for a long period of time, the continuous beeping may become undesired. Pressing the mute button will temporary disable the beeping for this sensor only, it will still beep if other sensors are triggered. This sensor will beep again if this window is closed, and then opened. OPERATION Mute Button 2. Change the buzzer mode - Disable Beeping The beeping can be disabled for all zones by changing the buzzer mode selector. - If the buzzer mode selector is at "I", beeping is enabled. - If the buzzer mode selector is at "II", beeping is disabled. If beeping is disabled, all sensor alert beeping will be disabled, however, the voice announcement and LED flashing will still function. 3. Enable Auto-Mute in Advanced Programming If this feature is enabled for that zone, beeping will be terminated automatically after 15 seconds . Refer to "Advanced Programming" - Auto Mute" on page 29 for more information on how to enable this feature. Buzzer Mode –16– HOME AUTOMATION The Control Panel can be used to control lights and home applicances with a Control Module, (Control Module is sold separately). Garage door opener can be controlled with a Garage Door Receive (sold separately). The Control Panel can control up to 5 Control Modules / Garage Door Receivers. There are 3 ways to control these modules / receivers: 1. Using the keypad on the control panel to operate these modules / receivers manually 2. Calling in away from home using a touch tone phone (Refer to “Remote Operation by Telephone”) 3. Setting up Event Trigger (Refer to Advanced Programming) These control modules should be programmed to the control panel as device 1 to 5. Please follow the programming instructions below to program these control modules. Learn Control Modules Both control panel and control module are transceivers, meaning they can transmit and receive signals from each other. For home automation, the user will initiate an action from the control panel, such as sending a signal to turn on the light, then the control module will receive such signal and respond. The control module will then send back a confirmation to the control panel to indicate the light has been turned on. Therefore, during programming, it is required to program 2 things: 1. Signal from control module to control panel (confirmation signal) 2. Signal from control panel to control module (command signal) Door open Lights on Turn on (command signal) Confirm on (confirmation signal) Control Panel Control Module –37–

The control panel continuously monitors the system status as well as all the

sensors status. It will monitor occurrences such as triggered sensors, low battery sensors, malfunction sensors, or phone line failure etc. In order to check the system status, user can press the “Status” button on the control panel, voice announcement will be made regarding the system and sensor status. When the “Status” button is pressed, you will be notified if any of the following events is occurring: - System armed or disarmed - Any triggered sensors - Any sensors with low battery warning - Any sensors with failure warning - Phone line failure Refer to page 20 for more details regarding system failures. Arming the System You should arm the system when you are the last person to leave the house. By arming the system, the control panel will call the preprogrammed emer- gency phone numbers and the siren will sound when break-in occurs. Caution: Only arm the system when nobody is expected to be inside the premises. When someone is expected to be within the premises, the system should not be armed. To arm the system, follow the procedures below: 1. Press [Arm] button on the control panel when no sensors are triggered. You can also use the keychain remote to arm the system by pressing button 1 on the remote. System Status –17– OPERATION OR 1. Press [Arm] on the control panel or keychain remote. 2. Leave the premises within 45 seconds. 3. After 45 seconds. System will be armed. Beep Beep Exit delay 45 seconds 45 seconds later ARM LED on. System Armed ADVANCED PROGRAMMING Zone 1 SENSOR 1 Button [1] SENSOR 2 Zone 2 Zone 3 Zone 4 Zone 5 Button [2] Button [3] Button [4] Button [5] Button [6] Button [7] Button [8] Button [9] Button [0] This row : Buttons for Sensor 1 Zone LED : Flash once This row : Buttons for Sensor 2 Zone LED : Flash twice ® Erase Sensors Proceed to the following to erase a sensor. 1 2 3 [PROG] [MPIN] Enter Programming mode Enter master password to programming mode 3 beeps for valid password. 1 long beep for invalid password. [9] Select erase remote programming After [9] is entered, some zone LEDs will flash or stay off. The zone LEDs represent whether that zone is occupied by any sensor. **See Table D below. Refer to the table below to select the remote location. Select the sensor you would like to erase After you have selected the sensor, you will hear 3 beeps and verbal confirmation [Zone X Sensor Y Empty Memory], where X and Y are the zone and sensor numbers you have selected. To erase an occupied sensor, press [1] to [0]. ZONE LED DESCRIPTION Off Zone is not occupied by any sensor Flashes once This zone is occupied by sensor 1. Flashes twice This zone is occupied by sensor 2. Flashes once, This zone is occupied by sensors 1 and 2. then twice ** Table D: Zone LED status for erasing sensors. Step Keys Function Description Note –36–

- The control panel cannot be armed if there are triggered sensors. Make sure

all sensors are in closed position, i.e. (close all doors, windows, no movement should be detected etc). - The control panel can be armed if there are sensors with low battery or failure warning. 2. After pressing the “ARM” button, the “ARM” LED will flash and you will have 45 seconds to leave the premises, this is called the exit delay. You will hear beeping during the exit delay interval. The beeping rate will change from slow to fast, the faster the beep rate, the less time you have left to leave the premises before the siren sounds. 3. When the exit delay expires, the control panel will announce “System Armed”, beeping will stop and the ARM LED will be on steadily. This indicates the system is now armed. Note: The control panel can also be armed remotely when nobody is home, with a touch tone phone. Please refer to “Remote Operation by Telephone” on page 24. Disarming the system If a sensor is triggered while the control panel is armed, such as entering a house with an armed control panel, an entry delay will be triggered. User is allowed to disarm the control panel during the 30-second entry delay. If the control panel is not disarmed within 30 seconds, siren will sound immediately and emergency calls will be made. To disarm the control panel, follow the instructions below. 1. During the entry delay, the system will beep for 30 seconds, the ARM LED will flash during this entry delay interval. The faster the beep, the less time you have left to disarm the control panel before the siren sounds. –18– OPERATION 1.Entering the premises will trigger the entry delay. 2.Enter password within 30 seconds or press the disarm button on the keychain remote. 3. Once the system is disarmed, the Arm LED will be off. OR Beep Beep Entry delay 30 seconds Arm LED off System Disarmed Beep Beep Arm LED flashes ADVANCED PROGRAMMING 4. Once you have filled out the table, it should look something like this. You may refer to each column representing the zone dependent feature, to program each zone with the selected feature. For example, Auto Mute feature is only enabled for zone 3, when you are in the auto mute programming, you should enable this feature for zone 3 only, the rest of the zones should have this feature disabled. Repeat this step for all 4 zone dependent features during programming. 5. You may now follow the procedure below "Learn Sensor Continue" to program the sensor(s) to the desired zone(s). Learn Sensors - Continue 1 2 3 4 [PROG] [MPIN] Enter Program- ming mode Enter master password to programming mode 3 beeps for valid password. 1 long beep for invalid password. [3] Select learn sensor programming [0] to [9] After you have selected the zone, that zone LED will be on. Trigger sensor After [3] is entered, some zone LEDs will flash once, or twice, some will be off. The zone LEDs represent whether that zone is already occupied by another sensor. ** Select sensor location Refer to the diagram below to select the sensor location, which includes the zone and sensor number. Once the sensor is activated, the signal w ill be transmitted to the Control Panel which will be stored. You will hear [Zone X Sensor Y Accepted], where X and Y are the zone and sensor numbers you have selected. Activate the sensor you would like to program to this zone. Basement Water Front Window Front Door SENSOR 1 SENSOR 2 Location Location ZONE DEPENDENT FEATURES Beep / Alarm Auto Mute Event Trigger Alert Kitchen Motion Back Door Basement Motion Backyard Motion Table C zone 1 Beep / Alarm Y / N Disabled / On / Off Y / N zone 2 Beep / Alarm Y / N Disabled / On / Off Y / N zone 3 Beep / Alarm Y / N Disabled / On / Off Y / N zone 4 Beep / Alarm Y / N Disabled / On / Off Y / N zone 5 Beep / Alarm Y / N Disabled / On / Off Y / N SENSOR 1 SENSOR 2 Location Location ZONE DEPENDENT FEATURES Beep / Alarm Auto Mute Event Trigger Alert zone 1 Beep / Alarm Y / N Disabled / On / Off Y / N zone 2 Beep / Alarm Y / N Disabled / On / Off Y / N zone 3 Beep / Alarm Y / N Disabled / On / Off Y / N zone 4 Beep / Alarm Y / N Disabled / On / Off Y / N zone 5 Beep / Alarm Y / N Disabled / On / Off Y / N Step Keys Function Description Note –35–

Disarming a triggered control panel

If "System Panic" is announced from the control panel after it has been disarmed, that means the alarm was triggered when it was in armed mode. Follow the procedures below to set the control panel back to standby mode. 1. If the alarm was caused by sensor(s), there will be flashing LEDs and beeping indicating which sensor(s) triggered the alarm. You may want to check the condition of the triggered sensor(s), the sensor(s) may be damaged if there were break-ins. 2. You need to reset the sensor manually by triggering it twice, i.e. open and then close a door / window sensor, or walk in front of the motion sensor. The LED representing that sensor will stop flashing after it receives the signal from the sensor. 3. You must now enter the password again on the control panel or press the disarm button on the keychain remote, as an acknowledgement of the alarm event. This will set the control panel back to standby mode. Disarming under Duress If you are forcibly compelled to disarm the control panel, you may enter the Duress Password. Entering the duress password will terminate the entry delay, i.e. no more entry delay beeping. But the control panel will silently call the emergency phone numbers for help. The called party will hear the voice announcement “System Panic”. Note: - The default duress password is [3838]. –19– Note: - The control panel can also be disarmed remotely when nobody is home, with a touch tone phone. Please refer to “Remote Operation by Telephone” on page 24. - If 3 consecutive incorrect passwords are entered, alarm will sound immediately, the control panel will be in panic mode, and start calling the emergency phone numbers. OPERATION 2. You must enter a valid password, either the Master Password, or Secondary Password to disarm the system before entry delay expires. The system can also be disarmed by pressing button 3 on the keychain remote. 3. When a valid password is entered, you will hear “System Disarmed” and the entry delay beeping will stop, the ARM LED will be off. ADVANCED PROGRAMMING Learn Sensors You can program up to 10 sensors to the control panel. There are 5 zones on the control panel, each zone can program up to 2 sensors. Before program- ming a sensor, you must decide which sensor location (zone number and sensor number) you would like to program the sensor to. It is strongly recom- mended that you refer to “Sensor Location Selection Guide” before deciding which sensor location you would like to program the new sensors to. Some features you may need to consider are: 1) Beep/Alarm setting, 2) auto mute, 3) alert zone , 4) event trigger. Explanation for each feature can be found in the following pages in Advanced Programming: 1. Beep/Alarm Setting - Page 26 2. Auto Mute - Page 29 3. Alert Zone - Page 30 4. Event Trigger - Page 42 Sensor Location Selection Guide You can program up to 10 sensors to the control panel. There are 5 zones and maximum 2 sesnors per zone. The 4 features mentioned above are Zone dependent features meaning both sensors in that zone will operate based on the setting for that zone. So if you program 2 sensors into one zone, those 2 sensors will react in the same manner for those zone dependent features. For example, if you enable the Auto-Mute feature for zone 1, both zone 1 sensor 1, and zone 1 sensor 2 will have this feature enabled. It is not possible to enable a zone dependent feature for sensor 1 only, but not sensor 2. Therefore, the followings are some suggestions of how you should select the sensor location. 1. Check all the zone dependent features, and determine if you would like to enable any one of them. 2. If you decide not to enable any zone dependent features and keep the factory default setting, you can simply program the sensor to any sensor location based on your own preference. Omit the following steps and proceed to "Learn Sensor - Continue". 3. If you decide to enable some of the zone dependent features, check Table C below. Circle the zone dependent feature selections. If there are features that you would like to enable for more than 2 sensors, you need to select more than one zone for those features. –34–

Pressing the panic button on the control

panel or keychain remote will cause the siren to sound and outgoing calls will be made to the preprogrammed phone numbers, “System Panic” will also be announced. This can be used in any emergency situation. To stop the siren and disarm the system, user can enter a valid password, or press the disarm button on the keychain remote. This will terminate the siren and the control panel from calling the rest of the emergency phone numbers. OR System Failure Control Panel constantly monitors itself and its sensors. If there are any trouble conditions, the control panel will advise the user. These trouble conditions include: - Phone Line Failure - Sensor Failure (loss of supervisory signal) - Low Battery – Control Panel - Low Battery – Sensors Phone Line Failure When the phone line is disconnected or malfunctions, the control panel will instantly notify the user by: 1. Both Power [PWR] and Program [PROG] LEDs will flash together; 2. Voice announcement “Phone Line Failure” will be played. When phone line failure occurs, please check the phone line connection, ensure the phone line is plugged into both the control panel and the wall socket securely. You should also check the phone line with a normal telephone to determine if it can dial out to a phone number. If it cannot dial out, that indicates the phone line is not in service, you should contact your local phone company. PANIC ARM DISARM AUX - Control other Skylink receiver such as Garage Door Receiver - Model 18R ADVANCED PROGRAMMING Erase Keychain / Keypad Remotes 1 2 3 [PROG] [MPIN] Enter Programming mode Enter master password to pro- gramming mode 3 beeps for valid password. 1 long beep for invalid password. [0] Select erase remote programming After [0] is entered, some zone LEDs will flash or stay off. The zone LEDs represent whether that zone is occupied by any remote. ** See Table B below. Select remote location you would like to erase After you have selected the remote location, you will hear 3 beeps and verbal confirmation [Device X Empty Memory], where X is the remote location you have selected. To erase an occupied remote, press [6] to [0]. Select a remote location [6], [7], [8], [9] or [0]. Remote [6] is represented by zone LED 1 ® ZONE LED DESCRIPTION Off Zone is not occupied by any remote Flashes twice This zone is occupied by a remote. You may select this zone to erase this remote. Flashes once This zone is occupied by a control module (Optional). THIS IS NOT A REMOTE CONTROL, THEREFORE, SHOULD NOT BE ERASED. (Refer to page 40 Erase Control Module for more information) Flashes once, This zone is occupied by a remote AND a control module. then twice You may select this zone to erase the remote. ** Table B: Zone LED status for erasing keychain/keypad remote(s). * Please refer to erase control module on page 40. Step Keys Function Description Note –33– ZONE LED 1 6 2 7 3 8 4 9 5 0 REMOTE LOCATION Follow the instructions below to erase keychain or keypad remotes / receivers.

When sensor failure occurs, try the following:

1. Check if the sensor is located at where it should be, and whether there is any physical damage to the sensor. 2. If the failed sensor is not physically damaged, try to activate the sensor and see if the control panel reacts to such activation. 3. If not, try to remove the sensor from its location, and bring it closer to control panel and activate the sensor. It is possible that the sensor is installed too far from the control panel and it cannot establish a steady communication with the control panel. If this is the case, please install the sensor closer to the control panel. Low Battery Control Panel The control panel is powered mainly by the adapter. However, during power outage, it will be powered by the 4 AAA backup batteries. Under standby conditions, these batteries can last for 48 hours. When the backup batteries are running low, the “LO BATT” LED on the control panel will be on, indicating you should replace the backup batteries. Ensure all 4 batteries are replaced altogether at the same time. After replacing the batteries, the “LO BATT” LED should be off, indicating the backup batteries are in good operating condition. Sensors All of the sensors are battery powered. Depending on the operating condition and environment, the battery life varies from 9 months to 2 years. 9V alkaline battery is used for the motion sensor, the battery life is approximately 9 months. Door / Window Sensor operates on a Lithium CR-2032 battery, with battery life of approxi- mately 2 years. OPERATION –21– Sensor Failure The control panel constantly monitors its sensors, if the control panel fails to communicate with any sensors, it will notify the user by: 1. The zone LED of the failed sensor will be on steadily; 2. Voice announcement “zone X sensor Y failure” will be played. ADVANCED PROGRAMMING ZONE LED DESCRIPTION Off Zone is not occupied by any remote Flashes twice This zone is occupied by another remote. Programming another remote to this zone will overwrite the previous remote. Flashes once This zone is occupied by a control module* (Optional). You can still program a remote to this zone, and it will not overwrite the control module* you have in this zone. (Refer to page 37 Home Automation for more information) Flashes once, This zone is occupied by a remote AND a control module*. then twice If you program another remote to this zone, it will overwrite the previous remote, but not the control module*. Learn Keychain / Keypad Remotes Additional keychain or keypad remotes can be programmed to the control panel. Maximum of 5 keychain/keypad remotes can be programmed to the control panel. - Keychain or keypad remotes should be programmed to Device 6 to Device 0. Follow the instructions below to program remote(s) to remote location(s) 6, 7, 8, 9, or 0, which is the bottom row of the numeric keypad of the control panel. 1 2 3 4 [PROG] [MPIN] Enter Program- ming mode Enter master password to programming mode 3 beeps for valid password. 1 long beep for invalid password. [4] Select learn remote programming After [4] is entered, some zone LEDs will flash or stay off. The zone LEDs represent whether that zone is already occupied by another remote. ** See Table A below. [6] to [0] Select remote location (Max. 5 remotes) Select a remote location [6], [7], [8], [9] or [0]. After you have selected the remote location, that zone LED will be on. Trigger remote Once the signal is transmitted to the Control Panel, that signal which will be stored. You will hear [Device X Accepted], where “X” is the remote location. Activate the remote by pressing any one of the buttons. ** Table A: Zone LED status for learning keychain/keypad remote(s). * Please refer to learn control module on page 37. Step Keys Function Description Note –32–

The battery of the keychain remote (Alkaline, Type 23A, 12V) needs to be replaced

when either one of the followings occurs: 1. The LED on the keychain doesn’t flash or on when a key is pressed; or 2. The operating range starts to decrease. To replace the battery: 1. Undo the two screws on the back of the transmitter. The bottom case will then come off. 2. Using a small screwdriver or pen, pry out the old battery from one end. 3. Place the new battery in position. A diagram in the battery compartment indicates which end is positive and which is negative. 4. Close the battery cover and reinsert two screws. OPERATION + - –22– When the sensor is running low in battery, the sensor will send a wireless low battery signal to the control panel. The zone LED representing that sensor will be on steadily, indicating sensor(s) in that zone is in trouble condition. Control Panel will also have an announcement to advise the user the trouble condition is low battery, such as “zone X sensor Y low battery”, where X and Y represent the zone and sensor number. Please replace the battery of that sensor. ADVANCED PROGRAMMING To enable alert zone feature, follow the instructions below. 1 2 3 4 Enter Program- ming mode Enter master password to programming mode 3 beeps for valid password. 1 long beep for invalid password. Refer to the diagram below to select the appropriate setting. [PROG] when finished. Terminate programming mode. PROG LED will be off. [8] If alert zone is selected, that zone LED will be on. If it is not selected, the LED will flash. You are allow to make multiple changes before terminat- ing programming mode. After [8] is entered, some zone LEDs will flash or stay on. This indicates whether alert zone is selected. Select Alert Zone. Select which zone you would like to select as Alert Zone. Disable Alert Zone: [1] to [5] Enable Alert Zone: [6] to [0]. [PROG] [MPIN] Zone 1 DISABLE ALERT ZONE Button [1] ENABLE ALERT ZONE Zone 2 Zone 3 Zone 4 Zone 5 Button [2] Button [3] Button [4] Button [5] Button [6] Button [7] Button [8] Button [9] Button [0] This row : Buttons to Disable Alert Zone Zone LED : Flash This row : Buttons to Enable Alert Zone Zone LED : ON ® Step Keys Function Description Note –31–

Receiving the Emergency Call

If you are on the list as one of the recipients of the emergency call, you should read the following instructions carefully. You should also notify all the persons you will be calling so they know how to react when they receive the emergency call. The control panel will call you when there are emergencies such as break-ins, smoke, fire events, or someone at home needs assistance. 1. When the phone rings at the calling location, the person who answers the phone will hear a message related to the emergency events, such as “System Panic”, or “Zone 1 Sensor 1 Triggered” etc. This message may be repeated several times depending on how it was programmed. 2. After the message has been repeated for a certain number of times, the control panel will ask for a valid password, you will hear “Enter Password”. 3. Enter the 4-digit password to have access to the control panel. If a valid password is accepted, you will hear “Password Accepted”, otherwise, you will hear “Password Failure”. 4. After entering the correct password, you can follow the “Phone Command” instruc- tions to perform the required tasks, such as disarm, turn on / off devices or check the system status etc. For further information of how to control the system remotely, please refer to the next section, "Remote Operation by Telephone". Zone 1 Sensor 1 Triggered Enter Password -Arm -Disarm -Check status -Control lighting etc. -Disconnect COMMUNICATION –23– Zone 1 DISABLE AUTO MUTE Button [1] ENABLE AUTO MUTE Zone 2 Zone 3 Zone 4 Zone 5 Button [2] Button [3] Button [4] Button [5] Button [6] Button [7] Button [8] Button [9] Button [0] This row : Buttons to Disable Auto Mute Zone LED : Flash This row : Buttons to Enable Auto Mute Zone LED : ON ® ADVANCED PROGRAMMING Alert Zone (Bypass Zone) As explained earlier, the control panel can operate in 2 different modes, 1) Alert Mode, 2) Alarm Mode. In alarm mode, when a sensor is triggered, the control panel will either give a 30 seconds entry delay, or siren will sound immediately (with instant alarm). However, there are sensors that you do not want to trigger the alarm when the system is armed. Such as an outdoor sensor, or any other sensors that you only want to give you alert notification. Under such circum- stances, zone(s) can be programed to react only when the control panel is in alert mode, these zones will be automatically bypassed when the control panel is in alarm mode. These zones can also be considered as "Bypass zones". It is recommend to enable alert zone if: - You do not consider the sensors in that zone an emergency - Sensors in that zone are located outdoors - When nobody is home, you do not want to know the status of the sensor(s) in that zone Factory Default: This feature was disabled for all zones at the factory. –30–

Remote Operation by Telephone

The control panel can be operated while you are away from home. You can have access to the control panel with any touch tone phone to perform a variety of operations, listed below. - Arm - Disarm - Lights, Home Applicances on / off (Requires additonal Control Module) - Garage door open / close (Requires additional Garage Door Receiver) - System status - Disconnect There are 2 ways you can have access to the remote phone operation: 1. You can call the control panel when you are away from home; or 2. When the control panel calls you during emergency. COMMUNICATION To access the control panel away from home Calling in when you are away from home 1. Call your home phone number, or the number that the phone line of the control panel is connected to. 2. Hang up after the second ring. 3. Wait at least 10 seconds, but not more than 40 seconds, then call the phone number again. 4. The control panel will pick up the phone call and request for a valid user password, you will hear “Enter Password”. You can enter either the Master Password or Secondary Password. If the password is correct, you will hear “Password Accepted”, otherwise, you will hear “Password Failure”. 5. Once the password is accepted, you can have access to all the operations listed below. –24– ADVANCED PROGRAMMING Auto Mute When a sensor is triggered in alert mode, audio warning will be emitted, either beep or alarm. For example, if a door is opened, the beep will not stop until the door is closed. If the door is open for 2 hours, the beep will go on for 2 hours. There are times that this is not desired. With the auto mute feature enabled, the beep will go on for only 20 seconds. After that, even if the sensor remains open, the beep will stop only the zone LED will flash to indicate the sensor is triggered. Beep will go on again if the sensor is closed and opened again. Note: Auto Mute only functions when the control panel is in alert mode (disarmed). If the control panel is in alarm mode (armed), a triggered sensor will result in entry delay or instant alarm. Factory Default: This feature was disabled for all zones at the factory. To enable auto mute feature, follow the instructions below. 1 2 3 4 [PROG] [MPIN] Enter Program- ming mode Enter master password to programming mode 3 beeps for valid password. 1 long beep for invalid password. [6] Select Auto Mute Enable / Disable After [6] is entered, some zone LEDs will flash or stay on. This indicates whether Auto Mute is enabled or disabled. Disable Auto Mute: [1] to [5] Enable Auto Mute: [6] to [0]. Select which zone you would like to enable / disable auto mute. Refer to the diagram below to select the appropriate setting. If auto mute is enabled, that zone LED will be on. If it is disabled, the LED will flash. You are allow to make multiple changes before terminating programming mode. [PROG] when finished. Terminate programming mode. PROG LED will be off, and you will hear 3 beeps. Step Keys Function Description Note –29–

Table 1: Remote Phone Operations

COMMUNICATION SYSTEM OPERATION PHONE COMMAND DESCRIPTION Turn on device x [x] = 1 to 5 Turn off device x x = [1 to 5] Check system status Arm Disarm Disconnect x+[*] x+[#] [8]+[#] [7]+[#] [9]+[#] [0]+[#] Turn devices on will hear [Device X On]. When the control module receives the on signal, it will turn on the plugged in device, and send a confirmation back to the control panel. You will then hear [Device On Accepted]. You will hear system status announcement You will hear [System Armed] Phone line disconnect You will hear [System Disarmed] Turn devices off will hear [Device X Off]. When the control module receives the off signal, it will turn off the plugged in device, and send a confirmation back to the control panel. You will then hear [Device Off Accepted]. –25– ADVANCED PROGRAMMING Follow the procedures below to program the beep / alarm setting. 1 2 [PROG] [MPIN] Enter Programming mode Enter master password to programming mode 3 beeps for valid password. 1 long beep for invalid password. [5] Select Beep / Alarm Setting After [5] is entered, some zone LEDs will flash or stay on. This indicates whether that zone is set to beep or alarm. 3 Set to Beep: [1] to [5] Set to Alarm: [6] to [0]. Select which zone you would like to Beep or Alarm. Refer to the diagram below to select the appro- priate setting. If Alarm is set for that zone, that zone LED will be on. If Beep is set, the LED will flash. You are allowed to make multiple changes before terminating programming mode. 4 [PROG] when finished. Terminate pro- gramming mode. PROG LED will be off, and you will hear 3 beeps. Zone 1 BEEP Button [1] ALARM Zone 2 Zone 3 Zone 4 Zone 5 Button [2] Button [3] Button [4] Button [5] Button [6] Button [7] Button [8] Button [9] Button [0] Example: If you would like to change the setting for zone 5 from “Beep” to “Alarm”, simply press [0] at step 3. This will change the zone 5 setting to “Alarm”. This row : Buttons for Beep Zone LED : Flash This row : Buttons for Alarm Zone LED : ON ® Step Keys Function Description Note –28–

Advanced Programming allows users to customize the control panel to react

differently under different conditions. Features such as: - When a sensor is triggered, the control panel can beep or alarm - Beeping can be terminated automatically after a fixed period of time for some sensors - Some sensors can be programmed to beep only, never alarm - When a door is open, turn lights on - Program additional sensors and remotes Programming Summary COMMAND DESCRIPTION [PROG] + [1] Program Phone Numbers [PROG] + [2] Program Password [PROG] + [3] Learn Sensors [PROG] + [4] Learn Keychain or Keypad Transmitters / Control Modules [PROG] + [5] Beep / Alarm Setting [PROG] + [6] Auto Mute Setting [PROG] + [7] Event Trigger Setting [PROG] + [8] Alert Zone (Bypass) Setting [PROG] + [9] Erase Sensors [PROG] + [0] Erase Keychain or Keypad Transmitters / Control Modules –26– Follow the instructions below to have access to Advanced Programming. Beep / Alarm User can customize the audio warning so that when a sensor is triggered, the control panel may beep or alarm may sound instantly. Depending on whether the control panel is armed or disarmed, the audio warning is different. System Disarmed (Alert Mode) If a zone is set to “Beep”, the control panel will beep when a sensor is triggered, until the sensor is deactivated. Motion Sensor will beep for 20 seconds for every detected movement. If a zone is set to “Alarm”, alarm will sound instantly when a sensor is triggered. Alarm will stop when the sensor is deactivated, or reaches a 3-minute time out period. System Armed (Alarm Mode) If a zone is set to “Beep”, the control panel will give entry / exit delay. If a zone is set to “Alarm”, the siren will sound immediately without entry delay - Alarm Mode (System Armed): If a sensor is triggered (i.e. opening a door) with the alarm setting on, the siren will sound immediately without entry delay, it is called “Instant Alarm”. The siren will not stop until the siren timeout or a valid password is entered. Control panel will call the emergency phone numbers to notify the users of the alarm situation. When a sensor is triggered, there are 4 options: ZONE SETTING OPERATING MODE BEEP ALARM Disarmed (Alert) 1) Beep 2) Alarm sounds immediately Armed (Alarm) 3) Entry / Exit Delay 4) Alarm sounds and calls preprogrammed phone numbers immediately Factory Default: All zones were programmed to Beep at the factory. ADVANCED PROGRAMMING You may consider to programming the zone(s) into Alarm mode if: - You need immediate attention if that sensor is triggered, such as flood sensor, smoke sensor etc. - The sensor will not be triggered on a daily basis, such as a door that you normally will not open, and if it opens, you would like to know immediately. –27– Caution: It is not recommended to program an outdoor sensor to Alarm mode, which may cause false alarm. For outdoor sensors, they should be programmed into an Alert Zone, please refer to page 30 for details.