Genelec 8030A Operating Manual
| Brand: | Genelec |
| Category: | Speakers |
| Model: | 8030A (Operating Manual) |
| File Type: | |
| File Size: | 1.68 Mb |
| Pages: | 32 |
Text of Genelec 8030A Operating Manual
Genelec 8030A Operating Manual 2-7
Betriebsanleitung 8-13
Manuel d’utilisation 14-19
Käyttöohje 20-26
Bruksanvisning 25-31
The bi-amplified GENELEC 8030A is a two way
active monitoring loudspeaker designed to be small
but still have high output, low coloration, and broad
bandwidth.
The 8030A is ideal for near field monitoring,
mobile vans, broadcast and TV control rooms, sur-
round sound systems, home studios, multimedia
applications and also for use with computer sound-
cards. As an active loudspeaker, it contains driv-
ers, power amplifiers, act
speaker to an unearthed mains supply or using an
unearthed mains cable.
Audio input is via a 10 kOhm balanced female
XLR connector labelled “INPUT”. An unbalanced
source may be used as long as pin 3 is grounded
to pin 1 at the unbalanced source connector (see
Figure 2).
The male XLR “OUTPUT” connector can be
used for daisy-chaining up to six 8030A’s together
or for connecting a Genelec 7050B subwoofer. The
volume control attenuates the
Treble Tilt (switch 1) attenuates the treble response
above 5 kHz by 2 dB, which can be used for smooth-
ening down an excessively bright sounding system.
Bass Tilt
Bass Tilt offers three attenuation levels for the bass
response below 1 kHz, usually necessary when the
loudspeakers are placed near room boundaries.
The attenuation levels are -2 dB (switch 3 “ON”), -4
dB (switch 4 “ON”) and -6 dB (both switches “ON”).
Bass Ro
Genelec 8030A Sufficient cooling for the amplifier and function-
ing of the reflex port must be ensured if the
loudspeaker is installed in a restricted space
such as a cabinet or integrated into a wall
structure. The surroundings of the loudspeaker
must always be open to the listening room with
a minimum clearance of 5 centimeters (2”)
behind, above and on both sides of the loud-
speaker. The space adjacent to the amplifier
must either be
Figure 4. The curves
show the effect of the
“Bass Tilt”, “Treble Tilt”
and “Bass Roll-Off” con-
trols on the free field re-
sponse of the 8030A
Figure 5. The upper
curve group shows the
horizontal directivity
characteristics of the
8030A measured at
1 m. The lower curve
shows the system's
power response.
50
100
55
60
65
70
75
80
85
90
95
d
B
r
A
20
20k
50
100
200
500
1k
2k
5k
10k
Hz
Genelec Oy 8030A