INNOVATIVE DESIGN & PROTOTYPE TESTING are key components

of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. ¡ TEST CRITERIA:  PROTOTYPE TESTED  NEMA MG1-22 EVALUATION  SYSTEM TORSIONAL TESTED  MOTOR STARTING ABILITY ¡ SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. An unequalled ±1% voltage regulation. ¡ SINGLE SOURCE SERVICE RESPONSE from Generac’s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. ¡ GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. GENERAC® GUARDIAN® SERIES STANDBY GENERATORS 60 kW Includes: • Generac Turbocharged/Aftercooled Gaseous Fueled 2.4L Engine • Two Line LCD Tri-lingual Digital Nexus™ Controller • Isochronous Electronic Governor • Sound Attenuated Enclosure • Closed Coolant Recovery System • Smart Battery Charger • UV/Ozone Resistant Hoses • ±1% Voltage Regulation • Natural Gas or LP Operation • 2 Year Limited Warranty • UL 2200 Listed Standby Power Rating Model QT060 (Steel - Bisque) - 60 kW 60Hz Model QT060 (Aluminum - Gray) - 60 kW 60Hz Liquid-Cooled Engine Generator Sets Meets EPA Emission Regulations Not for sale in CA/MA

Application & Engineering Data

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271). QT060 GENERATOR SPECIFICATIONS TYPE Synchronous ROTOR INSULATION Class H STATOR INSULATION Class H TELEPHONE INTERFERENCE FACTOR (TIF) <50 ALTERNATOR OUTPUT LEADS 3 PHASE 4 wire BEARINGS Sealed Ball COUPLING Flexible Disc LOAD CAPACITY (STANDBY RATING) 60 kW EXCITATION SYSTEM Direct VOLTAGE REGULATION TYPE Electronic SENSING Single Phase REGULATION ± 1% GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 120 °C above a 40 °C ambient Insulation is Class H rated at 150 °C rise All models are fully prototyped tested ENCLOSURE FEATURES Galvanized steel or aluminum weather protective enclosure Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability.  Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries.  Small, compact, attractive Makes for an easy, eye appealing installation. SAE Sound attenuated enclosure ensures quiet operation. ENGINE SPECIFICATIONS MAKE Generac MODEL In line CYLINDERS 4 DISPLACEMENT 2.4 Liter, 146 in. 3 BORE 3.41 STROKE 3.94 COMPRESSION RATIO 8.5:1 INTAKE AIR SYSTEM Turbocharged/Aftercooled LIFTER TYPE Hydraulic GOVERNOR SPECIFICATIONS TYPE Electronic FREQUENCY REGULATION Isochronous STEADY STATE REGULATION ± 0.25% ENGINE LUBRICATION SYSTEM OIL PUMP Gear OIL FILTER Full flow spin-on cartridge CRANKCASE CAPACITY 4 Quarts ENGINE COOLING SYSTEM TYPE Closed WATER PUMP Belt driven FAN SPEED 2100 FAN DIAMETER 22 inches FAN MODE Puller FUEL SYSTEM FUEL TYPE Natural gas, propane vapor CARBURETOR Down Draft SECONDARY FUEL REGULATOR Standard FUEL SHUT OFF SOLENOID Standard OPERATING FUEL PRESSURE 5” - 14” H2O ELECTRICAL SYSTEM BATTERY CHARGE ALTERNATOR 12V 30 Amp STATIC BATTERY CHARGER 2 Amp RECOMMENDED BATTERY Group 26, 525CCA SYSTEM VOLTAGE 12 Volts

KW RATING (LP/NG)

60/60 ENGINE SIZE 2.4 Liter 4 cyl. inline GENERATOR OUTPUT VOLTAGE/KW - 60Hz KW AMP CB Size 120/240V, 1-phase, 1.0 pf 120/208V, 3-phase, 0.8 pf 120/240V, 3-phase, 0.8 pf 277/480V, 3-phase, 0.8 pf 60 60 60 60 250 208 180 90 300 250 200 100 ENGINE FUEL CONSUMPTION (Natural Gas) (Propane) Exercise cycle 25% of rated load 50% of rated load 75% of rated load 100% of rated load* For Btu content, multiply ft3/hr x 2520 (LP) or ft3/hr x 1000 (NG) Natural Gas (ft3/hr.) 123 267 483 672 862 Propane (gal/hr.) cu ft/hr 1.34 49.3 2.7 101 5.0 183 7.0 255 9.0 327 ENGINE COOLING Air flow (inlet air including alternator and combustion air) ft3/min. System coolant capacity US gal. Heat rejection to coolant BTU/hr. Max. operating air temp. on radiator °C (°F) Max. ambient temperature °C (°F) 3,280 2.5 270,000 60 (150) 50 (140) COMBUSTION AIR REQUIREMENTS Flow at rated power 60 Hz cfm 180 SOUND EMISSIONS IN DBA Exercising at 7 meters Normal operation at 7 meters 65 72 EXHAUST Exhaust flow at rated output 60 Hz cfm Exhaust temp. at muffler outlet °F 494 1,050 ENGINE PARAMETERS Rated synchronous RPM 60 Hz 3600 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration 3% for every 10 °C above - °C 1.65% for every 10 °F above - °F Altitude Deration 1% for every 100 m above - m 3% for every 1000 ft. above - ft. 25 77 915 3000 * Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes. RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. KW rating is based on LPG Fuel and may derate with natural gas. Generac® Guardian® Series Standby Generator - 60 kW ®

NEXUS™ CONTROL FEATURES

2-Line Plain Text LCD Display Simple user interface for ease of operation. Mode Switch -Auto Automatic Start on Utility failure. 7 day exerciser. -Off Stops unit. Power is removed. Control and charger still operate. -Manual/Test (start) Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 10-30 seconds Standard Engine Start Sequence Cyclic cranking: 16 sec. on, 7 rest (90 sec. maximum duration) Engine Warm-up 5 seconds Engine Cool-Down 1 minute Starter Lock-out Starter cannot re-engage until 5 sec. after engine has stopped. Smart Battery Charger Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Automatic Low Oil Pressure Shutdown Standard Overspeed Shutdown Standard, 72Hz High Temperature Shutdown Standard Overcrank Protection Standard Safety Fused Standard Failure to Transfer Protection Standard Low Battery Protection Standard 50 Event Run Log Standard Future Set Capable Exerciser Standard Incorrect Wiring Protection Standard Internal Fault Protection Standard Common External Fault Capability Standard Governor Failure Protection Standard QT060 CUSTOMER SUPPLIED NEUTRAL WIRE LIQUID-COOLED INSTALLATION NEUTRAL BLOCK UTILITY SUPPLY FROM SERVICE DISCONNECT TO BE RUN IN TWO DIFFERENT CONDUITS. POWER LEADS AND TRANSFER SWITCH LEADS NOTE: N1 N1 CONNECTION PANEL QT SERIES ENGINE GENERATOR 23 194 TERMINAL NUMBERS NUMBERS TO MATCH WIRE NOTE: 23 194 178 183 T1/LINE ON 0 NEUT T1 N2 E1 N2 NEU E2 GROUND 0C4449A-T (DISTRIBUTION PANEL) CUSTOMER LOAD NEUTRAL BLOCK RTS TRANSFER SWITCH UTILITY STANDBY (C1 & VR1) (C2 & VR2) 0 GROUND 15B +12V 23 TRANSFER AIR 1 AIR 2 PRIORITY 1 PRIORITY 2 PRIORITY 3 PRIORITY 4 T1 NEUTRAL CONTACTOR 1 CONTACTOR 2 CONTACTOR 3 CONTACTOR 4 NOTE WIRE ORIENTATION WARNING TRANSFER DC COMMON CUSTOMER CONNECTIONS 23 0 194 +12VDC GROUND LOAD SHED MODULE 194 23 0 T1 N1 N2 48850-T E1 T1 E2 T2 T1 E1 N1 T2 E2 N2 N1 N2 *Single and three phase connections may vary, refer to the owner’s manual for specific connection information.

Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com

©2012 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0187700SBY-H / Printed in U.S.A. 06/28/12 ® Model # Product Description 5630 Cold Weather Kit If the temperature regularly falls below 32° F, install a cold weather kit to maintain optimal battery temperature. Kit consists of battery warmer with thermostat built into the wrap. 5616 Extreme Cold Weather Kit Recommended where the temperature regularly falls below 32° F for extended periods of time. For liquid cooled units only. 5651 Base Plug Kit Add base plugs to the base of the generator to keep out debris. 5703 Paint Kit Bisque Kit 5984 Scheduled Maintenance Kit The Liquid-Cooled Scheduled Maintenance Kits offer all the hardware necessary to perform a complete maintenance on Generac liquid-cooled generators. 5928 Nexus Wireless Remote Completely wireless and battery powered, Generac's Nexus wireless remote monitor provides you with instant status information without ever leaving the house. 5951 Advanced Nexus Wireless Remote Remotely control generator functions with the advanced model's LCD display. In addition to remote testing of the generator, set the excercise cycle and maintenance interval reminders. 5937 DLM Load Control Module (50 Amps) DLM Modules are used in conjunction with the Nexus Smart Switch to increase its load management capabilities. It gives the Nexus Smart Switch additional load management flexibility not found in any other transfer switch. AVAILABLE ACCESSORIES QT060