DanVex DEH-600wp Operation Manual

Specifications

Brand: DanVex
Category: Dehumidifier
Model: DEH-600wp (Operation Manual)
File Type: PDF
File Size: —
Pages: 22

Read Online

Read the DanVex DEH-600wp Operation Manual online using the built-in PDF viewer.

Text of the manual

EH 600wp, DEH-1000wp,

DEH-1700wp, DEH-2000wp, DEH-2500wp, DEH-4000wp. Operation manual Dehumidifiers

www danvex fi

1 Please read this manual carefully before using your dehumidifier and keep it well. If you have any question of using your dehumidifier please contact your local dealer.

www danvex fi

2 CONTENT Introduction................................................................................................................................3 Safety precautions.....................................................................................................................4 Dehumidifier description............................................................................................................6 Electric circuit diagrams...........................................................................................................10 Installation instructions............................................................................................................13 Start-up and operation.............................................................................................................15 Error messages.......................................................................................................................16 Denumidifier maintenance.......................................................................................................18 Technical specifications...........................................................................................................19 Warranty obligations................................................................................................................20

www danvex fi

INTRODUCTION MODELS: DEH-600wp DEH-1000wp DEH-1700wp DEH-2000wp DEH-2500wp DEH-4000wp All the dehumidifiers described in this manual are designed to adjust the indoor relative humidity from 40% RH to 99 % RH at the ambient temperature from +1O°C up to +32°C. 3

www danvex fi

4  Read these safety precautions carefully before the humidifier operation. Meanings of symbols used in this manual are shown below.  If dirt adheres to the power plug or the plug connection with the socket is non- tight, it may cause the fire or electric shock. SAFETY PRECAUTIONS WARNING Remove any dirt from the power cord. There should be no any damages in the power cord and its extensions. Do not scratch or overbend the power cord.  Do not put heavy objects on the power cord, do not heat it and do not expose it to any impacts. The cord may be damaged and it may cause the fire or electric shock. Consult your dealer for the unit installation. Do not insert your fingers or any objects in the air inlet/air outlet. Do not repair or reinstall of the unit by yourself.  If this is done incorrectly, it may cause the fire, electric shock, water leakage, etc.  Contact your local dealer. Don't do it under any circumstances Follow the instruction by all means Be sure to ground Disconnect the power cable from the electric mains. Never put anything on the unit Danger of electric shock, be careful Never insert fingers or any objects Do not disconnect/connect the power during the unit operation. When an abnormality (smell of burning. etc) occurs during the operation, stop the unit and disconnect it from the electric mains. Use the ground.  If the unit operates abnormally consult your dealer.  Prevent the contact of the grounding wire with a gas pipe, water pipe, lightning rod or telephone cable. If the grounding is made incorrectly, it may cause the electric shock.

www danvex fi

5  It may cause the fire or deformation of the housing. SAFETY PRECAUTIONS WARNING Do not pull the power cord. Do not apply an insecticide or flammable spray. Prior to the unit cleaning it should be switched. Disconnect the power cord from the electric mains.  It can cause the short circuit and lead the electric shock or fire. Do not clean the unit with water.  It may cause the electric shock.  Since the fan rotates at high speed during operation, the cleaning of the operating unit may cause an injury. If the unit is installed in the wet place, provide its insulation against the moisture ingress.  If the insulation against the moisture ingress isn't provided, it may cause the electric shock.  If not to do it, the dirt may collect in the unit and cause the fire. When the unit is not going to be used for a long time, disconnect it from the electric mains.  Do not install the unit where there is flammable gas. Do not install the unit where its operation is not safe. Do not operate switches with wet hands.  It may cause the electric shock. Don't try to install the unit by yourself.  If this is done incorrectly, it may cause the fire, electric shock, water leakage, etc.  Contact your local dealer.

www danvex fi

6  Dehumidifiers: DEH-600wp and DEH-1000wp DEHUMIDIFIER DESCRIPTION Power cord Air outlet Control panel RIGHT SIDE FRONT SIDE Air inlet Drain hose LEFT SIDE Base

www danvex fi

7  Dehumidifiers: DEH-1700wp и DEH-2000wp DEHUMIDIFIER DESCRIPTION Power cord Air outlet RIGHT SIDE FRONT SIDE Air inlet Drain hose LEFT SIDE Base Control panel

www danvex fi

8  Dehumidifiers: DEH-2500wp и DEH-4000wp DEHUMIDIFIER DESCRIPTION Power cord Air outlet RIGHT SIDE FRONT SIDE Air inlet Drain hose LEFT SIDE Base Control panel

www danvex fi

9  Dehumidifiers: DEHUMIDIFIER DESCRIPTION 1. Wall mounting bracket, 2 pcs. per dehumidifier set. 2. Anchor bolt, 6 pcs. per humidifier set (used for unit wall mounting). 3. Mounting screw, 4 pcs. per humidifier set (used for unit wall mounting). 4. Floor foot, 4 pcs. per humidifier set (used for unit floor mounting). 5. Wheel, 4 pc. per humidifier set (used for unit mobile mounting). 6. Drain hose, 1 pc. per humidifier set.

www danvex fi

10 DEH-600wp, DEH-1000wp Single phase (1PH/5o Hz) ELECTRIC CIRCUIT DIAGRAMS Humidity sensor Internal temperature sensor External temperature sensor To display PCB Transformer Main controller PCB Fan motor Compressor Power supply High pressure protection Low pressure protection

www danvex fi

11 DEH-1700wp, DEH-2000wp Single phase (1PH/50 Hz) ELECTRIC CIRCUIT DIAGRAMS Humidity sensor Internal temperature sensor External temperature sensor To display PCB Transformer Main controller PCB Fan motor Compressor Power supply High pressure protection Low pressure protection Pressure control valve

www danvex fi

12 DEH-2500wp, DEH-4000wp Three phases (3PH/50 Hz) ELECTRIC CIRCUIT DIAGRAMS Humidity sensor Internal temperature sensor Transformer Main controller PCB Fan motor Compressor Pressure control valve External temperature sensor To display PCB Low pressure protection High pressure protection Red Black White Gray Green PCB protection phases sequence

www danvex fi

13 INSTALLATION INSTRUCTIONS 2. How to install the dehumidifier on the floor: Step 1: Put the dehumidifier on the platform as it's shown on the picture. There are 4 holes on the base. Step 2: Install the floor feet in the base holes. Step 3: Move the dehumidifier to the necessary place. Step 4: Adjust the feet height as required. Step 5: Connect the drain hose to the dehumidifier. Switch the dehumidifier on for the trial operation. Check whether there is any abnormal vibration and noise. Step 6: Installation is finished and the dehumidifier is ready for the use. WHEELS INSTALLATION

www danvex fi

14 INSTALLATION INSTRUCTIONS 3. How to install the dehumidifier on the wall: Step 1: Choose the right installation position for the wall mounting according to the size of mounting holes and position of the wall bracket holes. The installation position should guarantee the dehumidifier horizontal position. Drilling places should be marked. Step 2: Use the percussive drilling machines to drill holes with 8 cm±0.5cm depth. Then take the nuts and gaskets of the anchor bolts and install them into the holes with the hammer. Step 3: Install the wall bracket with the anchor bolts on the right position. Please take care to fix the bracket well with the nuts and gaskets. And don't forget to keep the bracket in the right direction during the installation. Step 4: Mount the dehumidifier on the wall bracket and locate it in such a way that the holes in the dehumidifier base are aligned with the bracket holes. Fix the dehumidifier on the bracket with the fixing screws and gaskets. Step 5: Connect the drain hose to the dehumidifier. Switch the dehumidifier on for the trial operation. Check whether there is any abnormal vibration and noise. Step 6: Installation is finished and the dehumidifier is ready for the use. WHEELS INSTALLATION

www danvex fi

15 1. When electric supply is connected the display will show the current ambient humidity. i/ e. = indoor air humidity is 60%. 2. Buttons and turn the dehumidifier on and off. 3. Buttons and are used to set the desired humidity level. Every time you press these buttons, the humidity level will change by 5%. The adjustable range is from 25% RH to 80%RH. If you press the button when the display shows , it will be shown --%RH , that means the nonstop dehumidification. 4. Button is used to turn the electric heater (option) on and off. STARTUP AND OPERATION REMOTE CONTROL UNIT FUNCTIONS OF THE CONTROL PANEL AND REMOTE CONTROL UNIT ATTENTION! Please study the control functions carefully or make the necessary adjustments prior to the dehumidifier operation. CONTROL PANEL ON/OFF button DOWN button UP button RCU signal receiver Defrosting signal lamp Humidity level Fault signal lamp Electric heater signal lamp ON/OFF button UP button DOWN button

www danvex fi

16 ERROR MESSAGES E0: The defrosting system is not working correctly. Please contact your dealer. E1: The dehumidifying sensor is not working correctly. Please contact your dealer. E2: The external temperature sensor is not working correctly. Please contact your dealer. E3: Ambient temperature is over the working temperature. If the ambient temperature is over 32°C or below 10°C, it will display error message E3 too. Please contact your dealer. E4: The defrosting temperature sensor is not working correctly. Please contact your dealer. IF THE HUMIDIFIED STOPS WORKING THE DIPLAY WILL SHOW THE ERROR MESSAGE

www danvex fi

17 ERROR MESSAGES E5 (1): It is displayed when the unit is connected to the power for the first time and the phase error is found. Please contact your dealer. E5 (2): It is displayed during the running process and indicates that the current is exceeded or the phase is lacking. Clean the evaporator and condenser. Please contact your dealer. E6: Indicates the low pressure level. Please contact your dealer. E7: Indicates the high pressure level. Please contact your dealer. E8: The refrigerant level is insufficient. Please contact your dealer. IF THE HUMIDIFIED STOPS WORKING THE DIPLAY WILL SHOW THE ERROR MESSAGE

www danvex fi

18 DEHUMIDIFIER MAINTENANCE When you are going not to use the dehumidifier for a long time. When you want to use the dehumidifier. Start the air dehumidifying process for 3 – 4 hours installing the humidity level at 80% to dry the dehumidifier inside. Turn off the dehumidifier and then the disconnect the plug from the socket. Ensure that the air inlet and air outlet are not blocked. Ensure that the grounding wire is connected properly. WARNING Switch the dehumidifier off or disconnect the plug from the socket if you are not going to use it fro a long time. Dirt can be accumulated and cause the fire. WARNING Use the ground. Prevent the contact of the grounding wire with a gas pipe, water pipe, lightning rod or telephone cable. If the grounding is made incorrectly, it may cause the electric shock. Remove the batteries from the remote control unit.

www danvex fi

19 TECHNICAL SPECIFICATIONS NOTE: 1. Rated noise value is detected in the laboratory. 2. In case of the difference of the specifications indicated in the above table and the specifications indicated directly on the nameplate it's necessary to use the specifications of the nameplate. o 3. Test data: ambient temperature is 30 C, and the ambient humidity is 80%RH. SPECIAL INSTRUCTIONS: 1. Customer should contact the special service department for the qualified installation and repair. 2. If any flexible cable is damaged, contact the special service department to replace it with the original cable.

DanVex warrants that all the equipment parts will answer the technical requirements for 12

months from the date of delivery (warranty period). The warranty does not cover wearable parts such as filters. The warranty covers the defects in workmanship and materials. During the warranty period DanVex repairs and replaces the part having a defect of material or an manufacturing error. DanVex completely fulfills its warranty obligations when it supplies the Customer a repaired or a spare part. Parts repair or replacement does not result in the warranty period extension. The parts and components replaced under the warranty belong to DanVex. DanVex or its distributor upon DanVex request has a right to inspect the defective parts and to check the correctness of the warranty claim. Warranty repair execution conditions: The damage occurred during the equipment normal operation. All recommendations and instructions of the manufacturer concerning the equipment installation, operation and maintenance were observed. Only original parts and materials were used for the equipment maintenance and repair. R www danvex fi 20