Panasonic AVM3P (PS) Manual
Read Online
Read the Panasonic AVM3P (PS) Manual online using the built-in PDF viewer.
Text of the manual
• 10.1 Amp. high contact capacity is
available
• Long life
• Precise operating position
(±0.25mm: Pin plunger type)
• Flux-resistant construction with
integrally molded terminals
• In-line terminals make soldering
works easy
• UL/CSA approved
TYPICAL
APPLICATIONS
• Heaters
• Electric rice cookers
• Copiers
• Printers
• Facsimiles
• Vending machines
• Measuring equipment
• Audio equipment
Type of switch
PS switch
Actuators
0:
1:
2:
3:
4:
5:
Pin plunger
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Roller lever
Terminals
1:
2:
3:
4:
Self-standing solder terminal
with guard
Self-standing solder terminal
without guard
Self-standing solder terminal
with opposite side guard
Self-standing PC terminal
Operating force
by pin plunger, max.
5: 1.47 N
Capacity
P: High capacity
(10.1 A)
Agency
standard
9: UL/CSA
Ex.
AVM3
1
0
5
P
9
CONSTRUCTION
CONTACT
ARRANGEMENT: SPDT
DATA
Electrical life curve
COM
NO
NC
30
10
20
3
5
1
0
5
10
Load current (A)
No. of operations, ×104
AECTB12E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
RoHS compliant
1. Contact rating
2. Characteristics
3. Operating characteristics
DIMENSIONS
Contact
Actuator
Part No.
Self-standing solder terminal
Self-standing
PC terminal
Without guard
With guard
With opposite
side guard
Gold-clad
Pin plunger
AVM3205P9
AVM3105P9
AVM3305P9
AVM3405P9
Short hinge lever
AVM3215P9
AVM3115P9
AVM3315P9
AVM3415P9
Hinge lever
AVM3225P9
AVM3125P9
AVM3325P9
AVM3425P9
Long hinge lever
AVM3235P9
AVM3135P9
AVM3335P9
AVM3435P9
Simulated roller lever
AVM3245P9
AVM3145P9
AVM3345P9
AVM3445P9
Roller lever
AVM3255P9
AVM3155P9
AVM3355P9
AVM3455P9
Resistive load (cos φ ] 1)
10.1A, 250V AC
Expected life
Electrical
Min. 5 × 104 (at 20 cpm) (O.T. max.)
Mechanical
Min. 3 × 107 (O.T.: Specified value), at 60 cpm
Dielectric
strength
Between terminals
1,000 Vrms for 1 min. (at 10 mA)
Between terminals and other exposed metal parts
2,000 Vrms for 1 min. (at 10 mA)
Between terminals and ground
2,000 Vrms for 1 min. (at 10 mA)
Insulation resistance
Min. 100MΩ (at 500V DC)
Contact resistance (initial)
Max. 50mΩ (By voltage drop, 1A 6 to 8V DC)
Allowable operating speed (at no load)
0.1 to 1,000 mm/sec.
Max. operating cycle rate (at no load)
300 cpm
Ambient temperature
–25 to +85°C (Not freezing below 0°C)
Unit weight
Approx. 2g
Contact material
AgNi alloy
Actuator
Operating force,
Max.
Release force,
Min.
Pretravel, Max.
mm
Movement differential,
Max. mm
Overtravel, Min.
mm
Operating position
mm
Pin plunger
1.47 N
0.20 N
0.6 mm
0.1 mm
0.4 mm
8.4±0.25 mm
Short hinge lever
0.59 N
0.039 N
2.5 mm
0.5 mm
0.8 mm
8.8±0.8 mm
Hinge lever
0.54 N
0.034 N
2.8 mm
0.8 mm
1.2 mm
8.8±0.8 mm
Long hinge lever
0.44 N
0.029 N
3.5 mm
1.0 mm
1.6 mm
8.8±1.2 mm
Simulated roller lever
0.54 N
0.034 N
2.8 mm
0.8 mm
1.2 mm
11.65±0.8 mm
Roller lever
0.59 N
0.039 N
2.5 mm
0.5 mm
0.8 mm
14.5±0.8 mm
mm General tolerance: ±0.25
1. Self-standing PC terminal (Without guard)
Pin plunger
2.2
NO
NC
C
0.5
0.6 max.
8.7
15.4
0.9
7.4
0.75
9.5
1.8
6.4
5.2
1.25
0.5
4.0
(P.T.)
7.7
-0.05
+0.1
2.4
2.4
19.8
2.5
7.6
±0.3
±0.1
±0.15
±0.15
±0.3
±0.1
2.2
±0.1
±0.15
3.4
±0.1
±0.2
1.1
±0.12
1.5
±0.12
1.85
±0.2
6.7
8.4 ±0.25
(O.P.)
11.8
(O.P.)
±0.35
2.4
dia.
+0.1
-0.05
PC board pattern
8.7 ±0.15
15.4 ±0.1
Pin plunger position
(10.55)
3-1.2
dia.
±0.05
Pretravel, Max. mm
0.6
Movement differential,
Max. mm
0.1
Overtravel, Min mm
0.4
Operating
position
Distance from
mounting hole,
mm
8.4±0.25
CAD Data
AECTB12E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e
Short hinge lever
12.85
NO
NC
C
5.0
±0.4
2.5 max.
6.4
5.2
1.25
0.5
4.0
(P.T.)
±0.1
±0.2
1.1
±0.12
1.5
±0.12
1.85
±0.2
2.2
0.5
8.7
15.4
0.9
7.4
0.75
9.5
7.7
-0.05
+0.1
2.4
2.4
19.8
2.5
±0.1
±0.15
±0.15
±0.3
±0.1
2.2
±0.1
±0.15
3.4
6.7 8.8 ±0.8
(O.P.)
12.2
(O.P.)
±0.9
2.4
dia.
+0.1
-0.05
Pretravel, Max. mm
2.5
Movement differential,
Max. mm
0.5
Overtravel, Min mm
0.8
Operating
position
Distance from
mounting hole,
mm
8.8±0.8
mm General tolerance: ±0.25
CAD Data
Hinge lever
NO
NC
C
7.15
±0.4
12.85
2.8 max.
6.4
5.2
1.25
0.5
4.0
(P.T.)
±0.1
±0.2
1.1
±0.12
1.5
±0.12
1.85
±0.2
2.2
0.5
8.7
15.4
0.9
7.4
0.75
9.5
7.7
-0.05
+0.1
2.4
2.4
19.8
2.5
±0.1
±0.15
±0.15
±0.3
±0.1
2.2
±0.1
±0.15
3.4
6.7 8.8 ±0.8
(O.P.)
12.2
(O.P.)
±0.9
2.4
dia.
+0.1
-0.05
Pretravel, Max. mm
2.8
Movement differential,
Max. mm
0.8
Overtravel, Min mm
1.2
Operating
position
Distance from
mounting hole,
mm
8.8±0.8
CAD Data
Long hinge lever
NO
NC
C
13.1
±0.4
12.85
3.5 max.
6.4
5.2
1.25
0.5
4.0
(P.T.)
±0.1
±0.2
1.1
±0.12
1.5
±0.12
1.85
±0.2
2.2
0.5
8.7
15.4
0.9
7.4
0.75
9.5
7.7
-0.05
+0.1
2.4
2.4
19.8
2.5
±0.1
±0.15
±0.15
±0.3
±0.1
2.2
±0.1
±0.15
3.4
6.7
8.8 ±1.2
(O.P.)
12.2
(O.P.)
±1.3
2.4
dia.
+0.1
-0.05
Pretravel, Max. mm
3.5
Movement differential,
Max. mm
1.0
Overtravel, Min mm
1.6
Operating
position
Distance from
mounting hole,
mm
8.8±1.2
CAD Data
AECTB12E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
Simulated roller lever
mm General tolerance: ±0.25
R2.5
NO
NC
C
6.3
±0.4
12.85
2.8 max.
6.4
5.2
1.25
0.5
4.0
(P.T.)
±0.1
±0.2
1.1
±0.12
1.5
±0.12
1.85
±0.2
2.2
0.5
8.7
15.4
0.9
7.4
0.75
9.5
7.7
-0.05
+0.1
2.4
2.4
19.8
2.5
±0.1
±0.15
±0.15
±0.3
±0.1
2.2
±0.1
±0.15
3.4
6.7
2.4
dia.
+0.1
-0.05
11.65 ±0.8
(O.P.)
15.05
(O.P.)
±0.9
Pretravel, Max. mm
2.8
Movement differential,
Max. mm
0.8
Overtravel, Min mm
1.2
Operating
position
Distance from
mounting hole,
mm
11.65±0.8
CAD Data
Roller lever
3.2
5.0 dia.
NO
NC
C
2.5 max.
6.4
5.2
1.25
0.5
(P.T.)
±0.1
±0.2
1.1
±0.12
1.5
±0.12
1.85
±0.2
2.2
0.5
8.7
15.4
0.9
7.4
0.75
9.5
7.7
-0.05
+0.1
2.4
2.4
19.8
2.5
±0.1
±0.15
±0.15
±0.3
±0.1
2.2
±0.1
±0.15
3.4
6.7
2.4
dia.
+0.1
-0.05
14.5 ±0.8
(O.P.)
17.9
(O.P.)
±0.9
5.15
±0.4
12.85
Pretravel, Max. mm
2.5
Movement differential,
Max. mm
0.5
Overtravel, Min mm
0.8
Operating
position
Distance from
mounting hole,
mm
14.5±0.8
CAD Data
2. Self-standing solder terminal
Pin plunger
0.6 max.
8.7
15.4
R0.8
2.4
2.8
7.4
9.5
1.8
6.4
5.2
1.25
0.5
4.0
(P.T.)
7.7
-0.05
+0.1
2.4
2.4
19.8
2.5
NO
NC
C
7.6
±0.3
±0.1
±0.15
±0.15
±0.3
±0.2
2.2
±0.1
±0.15
3.4
R0.6
±0.1
±0.2
1.1
±0.12
1.5
±0.12
1.85
±0.2
6.7
8.4 ±0.25
(O.P.)
11.8
(O.P.)
±0.35
2.4
dia.
+0.1
-0.05
With guard
8*
24
With opposite
side guard
24
8*
* The height from the center of mounting hole to the edge of guard.
CAD Data
AECTB12E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
1. Fastening of the switch body
1) Use flat filister head M2.3 screws to
mount switches with less than a 0.29 N·m
torque. Use of screws washers or
adhesive lock is recommended to prevent
loosening of the screws.
2) Check insulation distance between
ground and each terminal.
3) When the operation object is in the
free position, force should not be applied
directly to the actuator or pin plunger
from vertical direction to the switch.
4) In setting the movement after
operation, the over-travel should be set
more than 70% as a standard. Setting the
movement at less than 70% of O.T. may
cause troubles such as miscontact and
welding due to small contact force of the
switch.
5) For a lever type, the force from the
reverse and side to the operation
direction should not be applied.
2. Soldering operations
Manual soldering should be
accomplished within 3 seconds with max.
350°C iron.
Care should be taken not to apply force
to the terminals during soldering.
Terminal portions must not be moved in
min.1 minute after soldering.
Also no tensile strength of lead wires
should be applied to terminals.
3. Selection of the switch
When specifying the switch, allow ±20%
to the listed operating characteristics.
4. Environment
Avoid using the switches in the following
conditions;
• In corrosive gases, such as silicon gas
• In a dusty environment
5. Cautions regarding use
When switching low-level circuits (6V DC
5mA, 12V DC 2mA, 24V DC 1mA), AV,
AV3/AVT3, AVL3 Au clad contact type
switches are recommended. When used
to switch inductive loads (relays,
solenoids, buzzers, etc.), it is
recommended that a proper spark
quench circuit is inserted in the switch to
prevent contact faults caused by electric
arcs. Care should be taken that
occurrence in AC load possibly shorten
the expected life.
6. Quality check under actual loading
conditions
To assure reliability, check the switch
under actual loading conditions. Avoid
any situation that may adversely affect
switching performance.
AECTB12E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e