1, 5, 20 min.

x Manual Until Dawn* x OPERATION Model CB-2011 Motion Sensor Light Control with Protective Lamp Shields © 2003 DESA Specialty Products™ 598-1111-01 * resets to Auto Mode at dawn. TEST Light Control Sensor Cover Plate Lamp Holders 6 Screws (3 sizes included) Gasket Features • Turns on lighting when motion is detected. • Automatically turns lighting off. • Photocell keeps the lighting off during daylight hours. Requirements • The Light Control requires 120-volts AC. • If you want to use the Manual Mode, the control must be wired through a switch. • Some codes require installation by a qualified electrician. • This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations. TEST 1 5 20 ON-TIME Put ON-TIME switch on the sensor bottom to TEST. MANUAL MODE ON-TIME TEST 1 5 20 ... back on. AUTO 1 Second OFF then... Move ON-TIME Switch to 1, 5 or 20 minutes Mode Switching Summary Flip light switch off for one second then back on* MANUAL MODE AUTO TEST Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate. Manual mode only works at night because daylight returns the sensor to AUTO. Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE. Manual mode works only with the ON-TIME switch in the 1, 5, or 20 position. * If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode. Mounting Bolt Mounting Strap Rubber Plug Plastic Hanger 2 PAR Lamps 2 Wire Connectors This package includes: Put the ON-TIME switch in the 1, 5, or 20 minute position.

For easy installation, select an existing light with a wall

switch for replacement. WIRE THE LIGHT CONTROL. ❒ Turn power off at the fuse or circuit breaker. ❒ Remove the existing light fixture. ❒ Install the mounting strap as shown using two screws that fit your junction box. ❒ The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap. ❒ Route the Light Control’s wires through the large gasket hole. MOUNT THE LIGHT CONTROL. ❒ Align the Light Control cover plate and cover plate gasket. Secure with the mounting bolt. ❒ Push the Rubber Plug firmly into place. ❒ If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant. For eave mount only: ❒ Swing the sensor head towards the clamp screw joint. If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done. ❒ Then rotate the sensor head clockwise 180° so the controls face down. Wall Mount Eave Mount For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. 1234567890123456789 1234567890123456789 1234567890123456789 Controls Clamp Screw Controls Controls Lock Nut To avoid water damage and elec- trical shock, keep lamp holders below horizontal. Keep lamps at least 1" (2.5 cm) from the sensor. Do not allow the lamps to block the lens. Lens ❒ Twist the junction box wires and fixture wires together as shown. Secure with wire connectors. White to White Black to Black Junction box ground wire to green ground screw on fixture. Gasket Mounting Strap Mounting Bolt Rubber Plug CAUTION: To avoid fire or burn hazards, keep fixture at least 2" (51mm) from combustible mate- rials. Do not aim at objects closer than 3' (1m). ❒ Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting. When screwing in the floodlamps, do not overtighten.

TEST AND ADJUSTMENT

❒ Turn on the circuit breaker and light switch. NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on or when switching modes wait 1 1/2 minutes. Bottom of Sensor Avoid aiming the sensor at: • Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering. • Areas where pets or traffic may trigger the control. • Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor. Maximum Range Maximum Coverage Angle 8 ft. (2.4 m) 70 ft. 100 ft. (21 m) (30.5 m) Boosted Least Sensitive Most Sensitive Sensor The detector is less sensitive to motion directly towards it. ❒ Loosen the clamp screw in the sensor ball joint and gen- tly rotate the sensor. ❒ Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the coverage area. Keep the sensor at least 1" (2.5 cm) away from the lamps. ❒ Adjust the RANGE as needed. RANGE set too high may increase false triggering. ❒ Secure the sensor head's aim by tightening the clamp screw. Do not over- tighten the screw. ❒ Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 20 minutes). Clamp Screw Ball Joint Aim Sensor Down for Short Coverage Aim Sensor Higher for Long Coverage SPECIFICATIONS Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft. (30.5 m) with Range Boost. [varies with surrounding temperature] Sensing Angle . . . . . . Up to 240° Electrical Load. . . . . . Up to 300 Watts Maximum In- candescent [Up to 150 Watts Maximum each lamp holder]. Power Requirements. 120 VAC, 60 Hz Operating Modes. . . . TEST, AUTO and MANUAL MODE Time Delay . . . . . . . . 1 , 5, 20 minutes DESA Specialty Products™ reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold. 240° B O O S T MAX MIN RANGE ON - TIME TEST 1 5 2 0 MINUTES ❒ Turn the RANGE control to the mid position and the ON-TIME control to the TEST position.

1. A flood lamp is positioned too close to

the sensor or pointed at nearby ob- jects that cause heat to trigger the sensor. (Reposition the lamp away from the sensor or nearby objects.) 2. Light Control is pointed toward a heat source like an air vent, dryer vent, or brightly-painted heat-reflective surface. (Reposition sensor. Reduce Range.) 3. Light Control is in Manual Mode. (Switch to Auto.) 1. Heat or light from the lamps may be turning the Light Control on and off. (Re- position the lamps away from the sensor.) 2. Heat being reflected from other ob- jects may be affecting the sensor. (Reposition sensor.) 3. Light Control is in the Test mode and warming up. (Flashing is normal un- der these conditions. Turn Boost off.) 1. Sensor is detecting its own lights. (Re- position lamps to keep area below the sensor relatively dark.) SYMPTOM Lights stay on continu- ously. Lights flash on and off. Lights flash once, then stay off in Manual Mode. SYMPTOM Lights will not come on. Lights come on in daylight. Lights come on for no apparent reason. POSSIBLE CAUSE 1. Light switch is turned off. 2. Flood light is loose or burned out. 3. Fuse is blown or circuit breaker is turned off. 4. Daylight turnoff is in effect (recheck after dark). 5. Incorrect circuit wiring, if this is a new installation. 6. Re-aim the sensor to cover desired area. 1. Light Control may be installed in a relatively dark location. 2. Light Control is in Test. (Set control switch to an ON-TIME position.) 1. Light Control may be sensing small ani- mals or automobile traffic (re-aim sensor). 2. Range is set too high. (Reduce Range setting.) TROUBLESHOOTING GUIDE 15 YEAR LIMITED WARRANTY This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province. For a period of fifteen years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you. Light bulbs are not covered. To obtain a refund or a replacement, return the product to the place of purchase. Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, or unauthorized service. This warranty covers only DESA Specialty Products™ assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF DESA SPECIALTY PRODUCTS™ FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEE- ABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Retain receipt for warranty claims. No Service Parts Available for this Product TECHNICAL SERVICE (Do Not Send Products) If you experience a problem, follow this guide. You may also want to visit our Web site at: www.desatech.com. If the problem persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to: DESA Specialty Products™ P.O. Box 90004, Bowling Green, KY 42102-9004 ATTN: Technical Service Specialty Products * If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.