Speed Queen AGS20AWF Installation Manual

Specifications

Brand: Speed Queen
Category: Dryer
Model: AGS20AWF
File Type: PDF
File Size: 1.07 Mb
Pages: 17

Read Online

Read the Speed Queen AGS20AWF Installation Manual online using the built-in PDF viewer.

Text of the manual

the Dryer ............................................................

5 Installer Checklist ................................................ Back Cover Para bajar una copia de estas instrucciones en espafiol, visite www.speedqueen.com. Keep these instructions for future reference. (If this machine changes ownership, this manual must accompany machine.) Date Purchased Model Number Serial Number www.speedqueen.com Part No. 512061R3 June 2007

in this manual

must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death. W033 ° Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. • WHAT TO DO IF YOU SMELL GAS: - Do not try to light any appliance. - Do not touch any electrical switch; do not use any phone in your building. - Clear the room, building or area of all occupants. - Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. - If you cannot reach your gas supplier, call the fire department. • Installation and service must be performed by a qualified installer, service agency or the gas supplier. W052 WARNING FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance, W053 The following information applies to the state of Massachusetts, USA. • This appliance can only be installed by a Massachusetts licensed plumber or gas fitter. • This appliance must be installed with a 36 inch (91 cm) long flexible gas connector. • A "T-Handle" type gas shut-off valve must be installed in the gas supply line to this appliance. • This appliance must not be installed in a bedroom or bathroom. (O Copyright 2007, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher. 2 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 512061

cm) / !

_ 0.4 in. | / 28 in. (1.1 cm) L (71.1 cm) *4.0 in. (10.2 cm) (68.3 cm) ELECTRIC DRYERS * With leveling legs turned into base. L .d DRY2203N 22.38 in. 8.0 in. (20.3 cm) 23.5 in. 28 in. (59.7 cm) ' (71,1 cm) *With leveling legs turned into base. 1 3/8 in. NPT Gas Connection 15.4 in. 39.1 cm] 26.9 in. _- 0.4 in. (68.3 cm) *2.8 in. (1.1 cm) (7 cm) *4.0 in. (10.2 cm) 2.3 in. (6cm) GAS DRYERS DRY2164N 512061 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 3

Before You Start

Supplies For most installations, the basic supplies you will need are: 8 2 ,/6 1 2 3 4 5 6 7 8 4 Safety Glasses Power Cord (Electric Models) Wrench Screwdriver Level 5/16 Inch Socket Wrench Duct Tape Teflon Tape (Gas Models) DRY2023N Parts Included An accessories bag has been shipped inside your dryer. It includes: • Installation Instructions • User's Guide • Product Registration Card • Dryer Rack Reply Card • Warranty Bond • Three screws (electric dryers only). Refer to Connecting Power CoM sections in Step 4 of Installation. Figure 1 WARNING Any disassembly requiring the use of tools must be performed by a suitably qualified service person. W299 4 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 512061

Level the Dryer

Install dryer before washer. This allows room for attaching exhaust duct. Select a location with a solid floor. Dryers installed in residential garages must be elevated 18 inches (46 cm) above the floor. No other fuel burning appliance should be installed in the same closet with the dryer. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. The dryers needs sufficient clearance and an adequate air supply for proper operation and ventilation, and for easier installation and servicing. (Minimum clearances are shown below). i :i iP;i ,/ *1L' A A -_.-C FRONT VIEW SIDE VIEW 3 FRONT VIEW (w/o Closet Door) (Closet Door) (Closet Door) D8231 Free Standing/Alcove Closet Installation Area Description Installation A Dryer sides and rear clearance 0 in. (0 cm) 0 in. (0 cm) B Dryer top clearance 12 in. (30.5 cm) 12 in. (30.5 cm) C Dryer front clearance Not Applicable 2 in. (5.1 cm) D Exhaust duct clearance to 2 in. (5.1 cm) 2 in. (5.1 cm) combustible material E Weather hood to ground clearance 12 in. (30.5 cm) 12 in. (30.5 cm) F Distance from floor or ceiling to Not Applicable 3 in. (7.6 cm) hole edge G* Area of centered air openings in Not Applicable 40 sq. in./open (260 sq. cm) closet door *Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown." 1 Closet Door 2 Centered Air Openings (G) (2 Openings minimum) 3 Outer Wall of Enclosure **NOTE: For new installations, locate top of wall vent 42 inches (106.7 cm) above floor to make venting easier to connect. Figure 2 512061 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 5

Place the dryer in position,

and adjust the legs until the dryer is level from side to side and front to back. The dryer must not rock. 2 1 1 2 3 Dryer Base Level Leveling Leg D6691 Figure 3 IMPORTANT: In mobile home installations, gas dryers MUST be permanently attached to the floor at the time of installation. Order No. 526P3 Dryer Installation Kit (available at extra cost) for a manufactured (mobile) home installation. Follow the instructions supplied with the kit. Step 2: Connect Dryer Exhaust System WARNING To reduce the risk of fire and combustion gas accumulation the dryer MUST be exhausted to the outdoors. W604 To reduce the risk of fire and the accumulation of combustion gases, DO NOT exhaust dryer air into a window well, gas vent, chimney or enclosed, unventilated area, such as an attic, wall, ceiling, crawl space under a building or concealed space of a building. W045 WARNING This gas appliance contains or produces a chemical or chemicals which can cause death or serious illness and which are known to the State of California to cause cancer, birth defects, or other reproductive harm. To reduce the risk from substances in the fuel or from fuel combustion, make sure this appliance is installed, operated, and maintained according to the instructions in this manual. Wl15 To reduce the risk of fire, DO NOT use plastic or thin foil ducting to exhaust the dryer. W354 • DO NOT use plastic or thin foil ducting. Rigid metal duct is recommended. /// //// DO DON'T DRY1915N Figure 4 • Locate dryer so exhaust duct is as short as possible. • Be certain old ducts are cleaned before installing your new dryer. • Use 4 inch (102 mm) diameter rigid or flexible metal duct. • The male end of each section of duct must point away from the dryer. • Use as few elbows as possible. • Use duct tape or pop-rivets on all duct joints. • Ductwork that runs through unheated areas must be insulated to help reduce condensation and lint build-up on pipe walls. 6 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 512061

must be secured

to mobile home structure. • Dryer exhaust duct MUST NOT terminate under mobile home. Dryer exhausts 220 cfm (measured at back of dryer). Static pressure in exhaust duct should not be greater than .6 inches water column (1.5 cm), measured with manometer placed on exhaust duct two feet (61 cm) from dryer (check with dryer running and no load). Exhausting dryer in hard-to-reach locations can be done by installing 521 P3 Flexible Metal Vent Kit (available as optional equipment at extra cost). Failure to exhaust dryer properly will void warranty. NOTE: Venting materials are not supplied with the dryer (obtain locally). Exhaust Direction The dryer can be exhausted to the outdoors through the back, left, right or bottom of the dryer. EXCEPTION: Gas dryers cannot be vented out the left side because of the burner housing. Dryer is shipped from factory ready for rear exhaust. Exhausting the dryer through sides or bottom can be accomplished by installing a Directional Exhaust Kit, 528P3, available as optional equipment at extra cost. Exhaust System For best drying results, recommended maximum length of exhaust system is shown in Table 1. To prevent backdraft when dryer is not in operation, outer end of exhaust pipe must have a weather hood with hinged dampers (obtain locally). NOTE: Weather hood should be installed at least 12 inches (30.5 cm) above the ground. Larger clearances may be necessary for installations where heavy snowfall can occm: Number of Weather Hood Type 90° Elbows Recommended Use Only for Short Run installations 4 in. 4 in. (10.2 cm) (10.2 cm) D6731 0 feet (13.7 m) 1 feet (10.7 m) 2 feet (9.1 m) 3 feet (7.6 m) 4 20 feet (6.1 m) NOTE: Deduct 6 feet (1.8 m) for each additional elbow. Table 1 2-1/2 in. (6.35 cm) Maximum length of 4 in. (10.2 cm)diameter rigid metal duct. 0 65 feet (19.8 m) 55 feet (16.8 m) 1 55 feet (16.8 m) 47 feet (14.3 m) 2 47 feet (14.3 m) 41 feet (12.5 m) 3 36 feet (11.0 m) 30 feet (9.1 m) 4 28 feet (8.5 m) 22 feet (6.7 m) Maximum length of 4 in. (10.2 cm) diameter flexible metal duct. 45 35 feet (10.7 m) 35 27 feet (8.2 m) 30 21 feet (6.4 m) 25 17 feet (5.2 m) 15 feet (4.5 m) D8021 512061 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 7

Step 3: (Gas

Dryer Only) Connect Gas Supply Pipe WARNING To reduce the risk of gas leaks, fire or explosion: • The dryer must be connected to the type of gas as shown on nameplate located in the door recess. • Use a new flexible stainless steel connector. • Use pipe joint compound insoluble in L.P. (Liquefied Petroleum) Gas, or Teflon tape, on all pipe threads. • Purge air and sediment from gas supply line before connecting it to the dryer. Before tightening the connection, purge remaining air from gas line to dryer until odor of gas is detected. This step is required to prevent gas valve contamination. • Do not use an open flame to check for gas leaks. Use a non-corrosive leak detection fluid. • Any disassembly requiring the use of tools must be performed by a suitably qualified service person. W316 . Make certain your dryer is equipped for use with the type of gas in your laundry room. Dryer is equipped at the factory for Natural Gas with a 3/8 inch NPT gas connection. NOTE: The gas service to a gas dryer must conform with the local codes and ordinances, or in the absence of local codes and ordinances, with the latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54 or the CAN/CGA-B149, National Gas Installation Code. Natural Gas, 1000 Btu/ft 3 (37.3 MJ/m 3) service must be supplied at 6.5 + 1.5 inch water column pressure. For proper operation at altitudes above 3000 feet (915 m) the natural gas valve spud orifice size must be reduced to ensure complete combustion. Refer to Table 2. Natural Gas Altitude Adjustments Altitude feet m 3000 915 6000 1830 8000 2440 9000 2740 10,000 3050 Orifice Size No. inches mm 43 0.0890 2.26 44 0.0860 2.18 45 0.0820 2.08 46 0.0810 2.06 47 0.0785 1.99 Table 2 . Part No. 503778 58719 503779 503780 503781 Remove the shipping cap from the gas connection at the rear of the dryer. Make sure you do not damage the pipe threads when removing the cap. 3. Connect to gas supply pipe. NOTE: When connecting to a gas line, an equipment shut-off valve must be installed within 6 feet (1.8 m) of the dryel. An 1/8 in. NPT pipe plug must be installed as shown for checking inlet pressure. Refer to Figure 5. 1 3 2 3 4 D6991 New stainless steel flexible connector - (Use design CSA certified connector) Use only if allowed by local codes 1/8 in. NPT Pipe Plug Equipment Shut-Off Valve Black Iron Pipe Shorter than 20 ft. (6.1 m) - Use 3/8 in. (9.5 mm) pipe 3/8 in. NPT Gas Connection Figure 5 8 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 512061

Turn on gas and

check all pipe connections (internal & external) for gas leaks with a non-corrosive leak detection fluid. NOTE: The dryer and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa). Refer to Step 9 (Check Heat Source). L.P. (Liquefied Petroleum) Gas, 2500 Btu/ft 3 (93.1 MJ/m 3) service must be supplied at 10 + 1.5 inch water column pressure. For proper operation at altitudes above 3000 feet (915 m) the L.R gas valve spud orifice size must be reduced to ensure complete combustion. Refer to Table 3. L.P. Altitude Adjustments Altitude feet m 3000 915 8000 2440 Orifice Size No. inches mm 55 0.0520 1.32 56 0.0465 1.18 Table 3 Part No. 58755 503786 NOTE: DO NOT connect the dryer to L.P. Gas Service without converting the gas valve. Install L.P. Gas Conversion Kit 649P3, available at extra cost. Step 4: (Electric Dryer Only) Connect Electrical Plug Dryer requires 120/240 Volt or 120/208 Volt, 60 Hertz, 3 or 4 wire electrical suppy. Refer to serial plate for specific electrical requirements. NOTE: The wiring diagram is located inside the control hood. WARNING To reduce the risk of fire, electric shock, serious injury or death, all wiring and grounding MUST conform with the latest edition of the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, and such local regulations as might apply. It is the customer's responsibility to have the wiring and fuses installed by a qualified electrician to make sure adequate electrical power is available to the dryer. W521 Grounding Information This dryer must be connected to a grounded metal, permanent wiring system; or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer. The dryer has its own terminal block that must be connected to a separate branch, 60 Hertz, single phase circuit, AC (alternating current) circuit, fused at 30 Amperes (the circuit must be fused on both sides of the line). Electrical service for the dryer should be of maximum rated voltage listed on the nameplate. Do not connect dryer to 110, 115, or 120 volt circuit. Heating elements are available for field installation in dryers which are to be connected to electrical service of different voltage than that listed on nameplate, such as 208 Volt. If branch circuit to dryer is 15 feet (4.57 m) or less in length, No. 10 AWG wire (copper wire only), or as required by local codes. If over 15 feet (4.57 m), use No. 8 AWG wire (copper wire only), or as required by local codes. Allow sufficient slack in wiring so dryer can be moved from its normal location when necessary. The power cord connection between wall receptacle and dryer terminal block IS NOT supplied with dryeL Type of power cord and gauge of wire must conform to local codes. 512061 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 9

Cord with Three-Wire

Plug NOTE: Four-wire cord is required for mobile homes or where codes do not permit grounding through neutral. NOTE: The power cord is NOT supplied with the electric dryer. Type of power cord and gauge of wire must conform to local codes and instructions. POWERSUPPLY POWER SUPPLY The method of wiring the dryer is optional and subject to local code requirements. NOTE: Connect the dryer to the power supply with the MAXIMUM RATED VOLTAGE listed on the nameplate. 120 -+ V.A.C. V.A.C. A typical 30-Amp Three-Wire Receptacle NEMAType 10-30R ±12 V.A.C. INTERMEDIATE FUSE BOX (may be omitted if service entrance box is fused) WALL RECEPTACLE NOTE: Use COPPER WIRE only. Shorter than 15 ft. (4.5 m) - use 10 AWG Longer than 15 ft. (4.5 m) - use 8 AWG 2 6 INTERMEDIATE SHUT-OFF BOX (may or may not be fused) L1 L2 L1 L2 POWER CORD CONNECTION DIRECT CONNECTION 2 3 3 Wire Grounded Neutral 120/240 Volt, 60 Hertz AC 1 Phase Service Entrance Switch Box (Refer to NOTE above) 30 Ampere Fuses or Circuit Breaker Neutral Wire 5 6 7 Metallic or Non-Metallic Sheathed Cable (Copper Wire Only) Power Cord (Not supplied with dryer) Neutral Terminal Block in Dryer D8161 1. Disconnect power to dryer. 2. Remove access cover from rear of dryer. Figure 6 3. Use a strain relief and insert end of power cord through power supply hole. Figure 7 D6951 Figure 8 D6961 10 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 512061

Use the three screws

from the accessories bag to attach the power cord wires to the terminal block. Refer to Figure 9. 1\ 3 1 2 3 "L1" Terminal Neutral Terminal "L2" Terminal D2861 Figure 9 5. Tighten all screws firmly. IMPORTANT: Failure to tighten these screws firmly may result in wire failure at the terminal block. . . Secure the strain relief to the power cord, or wires, where they enter the dryer cabinet. Check the continuity of the ground connection before plugging the cord into an outlet. Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet. 8. Reinstall access cover and screw. Connecting Power Cord with Four-Wire Plug NOTE: Four-wire cord is required for mobile homes or where codes do not permit grounding through neutral. 1 / 4" 0 V.A.C. DRY2016N 1 Typical Four-Wire Receptacle 2 Power Cord - Not Supplied with Dryer 3 Strain Relief Nut 4 Strain Relief Figure 10 1. Disconnect power to dryer. 2. Remove access cover from rear of dryer. C Figure 11 D6951 512061 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 11

screw and save for use in Step 5.

Remove wire and use in Step 6. 5. Attach power cord ground (green) wire to rear bulkhead using ground screw removed in Step 3. . 1 Ground Screw D6971 Figure 12 Use a strain relief and insert end of power cord through power supply hole. Figure 13 D6961 1 White 2 "L2" Terminal 3 Black 4 Green 5 Red 6 Neutral Terminal 7 "LI" Terminal DRY1920N . Figure 14 Use the three screws from the accessories bag to attach the remaining power cord wires to the terminal block as follows: a. Red wire to "L 1" terminal. b. Black wire to "L2" terminal. c. White wire to Neutral terminal. NOTE: When installing the white wire, loop the free eyelet end of the ground wire (removed in Step 3) and attach along with the white wire to the neutral (center) terminal on the terminal block. 7. Tighten all screws firmly. IMPORTANT: Failure to tighten these screws firmly may result in wire failure at the terminal block. . . Secure the strain relief to the power cord, or wires, where they enter the dryer cabinet. Check the continuity of the ground connection before plugging the cord into an outlet. Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet. 10. Reinstall access cover and screw. 12 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 512061

The door on this dryer is completely

reversible. To reverse door proceed as follows: 1. Remove four hinge attaching screws. D6751 2. Remove all nine screws. . D272P Pull bottom of door liner out, then pull down, removing door liner from door panel. . --0.Ai oR_1916N Rotate door panel 180 degrees as shown. D273P . . Remove door strike from door liner and reinstall on opposite side. DRY1917N Insert liner under flange on bottom of door, then push top of door liner into place. . DRY1918N Reinstall nine screws removed in Step 2. . DRY1919N Using screwdriver, remove two door plugs, and reinstall on opposite side of door opening. \q I D6201 512061 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 13

four hinge attaching

screws, removed in Step 1. li !7.,d_ ///1: Step 6: Wipe Out Inside of Dryer Before using dryer for the first time, use an all-purpose cleaner, or a detergent and water solution, and a damp cloth to remove shipping dust from inside dryer drum. D6181 Figure 15 Step 7: Plug In the Dryer Electric Dryer Connect the dryer to an electrical power source. Refer to Step 4 for information on connecting power cord. Connect to 30 Amp circuit. Figure 16 D2751 Gas Dryer Dryer requires 120 Volt, 60 Hertz electrical supply and comes equipped with a 3-prong grounding plug. Refer to serial plate for specific electrical requirements. NOTE: The wiring diagram is located inside the control hood. WARNING To reduce the risk of fire, electric shock, serious injury or death, all wiring and grounding MUST conform with the latest edition of the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1, and such local regulations as might apply. It is the customer's responsibility to have the wiring and fuses installed by a qualified electrician to make sure adequate electrical power is available to the dryer. W521 When plugging in the dryer: • Do not overload circuits. • Do not use an adapter. • Do not use an extension cord. • Do not operate both a washer and gas dryer on the same circuit. Use separetely fused 15 amp circuits. The dryer is designed to be operated on a separate branch, polarized, three-wire, effectively grounded, 120 Volt, 60 Hertz, AC (alternating current) circuit protected by a 15 Ampere fuse, equivalent fusetron or circuit breaker. The three-prong grounding plug on the power cord should be plugged directly into a polarized three-slot effectively grounded receptacle rated 120 Volts AC (alternating current) 15 Amps. Refer to Figure 17 to determine correct polarity of the wall receptacle. 14 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 512061

The dryer must be grounded.

In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. The dryer is equipped with a cord having an equipment-grounding conductor and a 3 prong grounding plug. The three-prong grounding plug on the power cord should be plugged directly into a polarized three-slot effectively grounded receptacle rated 110/120 Volts AC (alternating current) 15 Amps. WARNING This dryer is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three- prong receptacle. Do not cut or remove the grounding prong from this plug. W036 WARNING Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the dryer is properly grounded. W038 Do not modify the plug provided with the dryer - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. NOTE: Have a qualified electrician check the polarity of the wall receptacle. If a voltage reading is measured other than that illustrated, the qualified electrician should correct the problem. Do not operate other appliances on the same circuit when this appliance is operating. WARNING To reduce the risk of an electric shock or fire, DO NOT use an extension cord or an adapter to connect the dryer to the electrical power source, W037 _1 L 120+_12 V.A.C Plug cord into separately fused 15 Amp circuit. DRY2022N 1 "L1" 2 Ground 3 Neutral 4 Neutral Side 5 Round Grounding Prong Figure 17 Step 8: Recheck Steps 1-7 Refer to Installer Checklist on the back cover of this manual and make sure that dryer is installed correctly. Step 9: Check Heat Source Electric Dryers Close the loading door and start the dryer in a heat setting (refer to the Operating Instructions supplied with the dryer). After the dryer has operated for three minutes, the exhaust air or exhaust pipe should be warm. 512061 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 15

To view the burner

flame, remove the lower front panel of the dryer. Close the loading door, start the dryer in a heat setting (refer to the Operating Instructions supplied with the dryer); the dryer will start, the igniter will glow red and the main burner will ignite. IMPORTANT: If all air is not purged out of gas line, gas igniter may go off before gas is ignited. If this happens, after approximately two minutes igniter will again attempt gas ignition. After the dryer has operated for approximately five minutes, observe burner flame through lower front panel. Adjust the air shutter to obtain a soft, uniform blue flame. (A lazy, yellow-tipped flame indicates lack of air. A harsh, roaring, very blue flame indicates too much air.) Adjust the air shutter as follows: . 2. . Loosen the air shutter lockscrew. Turn the air shutter to the left to get a luminous yellow-tipped flame, then turn it back slowly to the right to obtain a steady, soft blue flame. After the air shutter is adjusted for proper flame, tighten the air shutter lockscrew securely. 4. Reinstall the lower front panel. AI WA N,NG For personal safety, lower front panel must be in place during normal operation. W046 After the dryer has operated for approximately three minutes, exhaust air or exhaust pipe should be warm. 1 2 Air Shutter Lockscrew Appliance Main Gas Valve 3 4 Air Shutter 1/8 in. (3.1 mm) Pipe Plug (For checking manifold pressure) D7021 Figure 18 16 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 512061

Fast Track for Installing

the Dryer (Refer to the manual for more detailed information) • Position and Level the Dryer. LEVEL CHECK D2591 O • Wipe Out Inside of L Dryer. i!, CHECK D6181 O. Connect Dryer CHECK DRY1915N I • Plug_heD_ _1 Electric D2751 _ D2541 CHECK -- GAS ONLY • Connect Gas _ Supply Pipe Hoses. • Check for Gas Leaks. i HECK .- ELECTRIC ONLY Connect Electrical Cord. CHECK O • Reverse Door, , if Desired. CHECK W6751 1L O • Recheck Steps 1-7. D2581 _ CHECK 1 W3151EOA O • Check Heat _ Source. CHECK D7021