Copyright © 2002-2012 Brocade Communications Systems, Inc. All Rights Reserved.
Brocade, Brocade Assurance, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, MLX, NetIron, SAN Health, ServerIron,
TurboIron, VCS, and VDX are registered trademarks, and AnyIO, Brocade One, CloudPlex, Effortless Networking, ICX, NET Health,
OpenScript, and The Effortless Network are trademarks of Brocade Communications Systems, Inc., in the United States and/or in
other countries. Other brands, products, or service names mentioned may be trademarks of their respective owners.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning
any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to
this document at any time, without notice, and assumes no responsibility for its use. This informational document describes
features that may not be currently available. Contact a Brocade sales office for information on feature and product availability.
Export of technical data contained in this document may require an export license from the United States government.
The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with
respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that
accompany it.
The product described by this document may contain “open source” software covered by the GNU General Public License or other
open source license agreements. To find-out which open source software is included in Brocade products, view the licensing
terms applicable to the open source software, and obtain a copy of the programming source code, please visit
http://www.brocade.com/support/oscd.
Brocade Communications Systems, Incorporated
Document History
Corporate and Latin American Headquarters
Brocade Communications Systems, Inc.
130 Holger Way
San Jose, CA 95134
Tel: 1-408-333-8000
Fax: 1-408-333-8101
E-mail: [email protected]
Asia-Pacific Headquarters
Brocade Communications Systems China HK, Ltd.
No. 1 Guanghua Road
Chao Yang District
Units 2718 and 2818
Beijing 100020, China
Tel: +8610 6588 8888
Fax: +8610 6588 9999
E-mail: [email protected]
European Headquarters
Brocade Communications Switzerland Sàrl
Centre Swissair
Tour B - 4ème étage
29, Route de l'Aéroport
Case Postale 105
CH-1215 Genève 15
Switzerland
Tel: +41 22 799 5640
Fax: +41 22 799 5641
E-mail: [email protected]
Asia-Pacific Headquarters
Brocade Communications Systems Co., Ltd. (Shenzhen WFOE)
Citic Plaza
No. 233 Tian He Road North
Unit 1308 – 13th Floor
Guangzhou, China
Tel: +8620 3891 2000
Fax: +8620 3891 2111
E-mail: [email protected]
Title
Publication
number
Summary of changes
Date
Diagnostic and System Error
Message Reference v3.0, v4.0
53-0000210-02
First release
March 2002
Diagnostic and System Error
Message Reference v3.1.0
53-0000511-04
Major content reorganization
June 2003
Diagnostic and System Error
Message Reference v4.1.0
54-0000515-02
Major content reorganization
June 2003
Diagnostic and System Error
Message Reference v4.1.2
53-0000515-06
Minor editorial changes
October 2003
Diagnostic and System Error
Message Reference v4.2.0
53-0000515-07
Added FW and PLATFORM messages
December 2003
Diagnostic and System Error
Message Reference v4.2.0
53-0000515-08
Updated software and hardware support
March 2004
Fabric OS System Error Message
Reference Manual
53-0000515-09
Updated for v4.4.0,
First RASLog release
August 2004
Fabric OS System Error Message
Reference Manual
53-0000515-10
Added 22 ZONE messages
April 2005
Fabric OS System Error Message
Reference Manual
53-0000515-11
Added FICU-1010, HAMK-1004, and
PLAT-1001
July 2005
Fabric OS System Error Message
Reference Manual
53-1000046-01
Added BM, FCR, IPS, FCIP, SEC, and
ZONE messages
January 2006
Fabric OS System Error Message
Reference Manual
53-1000046-02
Minor updates to a few messages.
June 2006
Fabric OS Message Reference
53-1000242-01
Updated for Fabric OS v5.2.0:
-Changed doc title and number
-Added the following new modules: IBPD,
ICPD, ISCSI, ISNSCD.
Added Audit messages: AUTH, CONF,
HTTP, SEC, SNMP, SULB, ZONE.
-Updated Introduction chapter with AUDIT
log information.
-Updated chapter titles.
September 2006
Fabric OS Message Reference
53-1000437-01
Updated for Fabric OS v5.3.0:
-Added new chapters: AG, BKSW, IBD,
IPAD, SAS.
Revised and added new messages to:
AUTH, CDR, CONF, EM, FABR, HAM, ISNS,
ISW, PDM,SEC,TS, KTRC.SEC, TS.
Revised/updated BL,BLL,FCPD, FICU,FW,
HIL,LOG, SNMP, SULB,SWCH,SYSM,
TRCE, ZOLB, ZONE.
-Deleted USWD chapter.
-Updated Introductory chapters.
-Updated throughout: rebranding,
supported hardware, CLI changes.
June 2007
Fabric OS Message Reference
53-1000600-01
Updated for Fabric OS v6.0.0:
-Added new chapters: C2, ESS, FICON
-Added new messages to: AG, BL, BM,
C2, FCIP, ISW, NS, PLAT, SS, HIL.
-Added Audit messages: SEC, SULB
-Updated Introductory chapters.
October 2007
Fabric OS Message Reference
53-1000600-02
Updated for Fabric OS v6.1.0:
-Revised and added new messages to:
AG, BL, C2, EM, FABR, FCR, FCIP, FW,
SEC, NS, PDM, PLAT, SULB, SWCH, ZONE,
WEBD.
-Added new Audit chapter: FW.
-Added new Audit messages to: SEC.
-Updated Introductory chapters.
Jun 2008
Fabric OS Message Reference
53-1001116-01
Updated for Fabric OS v6.1.1_enc:
-Revised and added new messages to AG
-Added new chapters: CNM, CTAP, CVLC,
CVLM, KAC, RKD, SPC, SPM.
-Added new Audit chapters: AG, FCIP,
FICU, IPAD, PORT, SWCH, UCST.
-Updated Introductory chapters.
Aug 2008
Title
Publication
number
Summary of changes
Date
Fabric OS Message Reference
53-1001157-01
Updated for Fabric OS v6.2.0:
-Revised and added new messages to
FSS, KSWD, CTAP, CNM, CVLM, EM,
FABR, FCIP, FW, HIL, FCR, SEC, SWCH,
UCST, ZONE.
-Added new chapters: CHASSIS, LFM,
PMGR, TAPE.
-Updated Introductory chapters.
November 2008
Fabric OS Message Reference
53-1001338-01
Updated for Fabric OS v6.3.0:
-Modified a message to BKSW, BL,
BKSW, BLL, CDR, CEE CONFIG, CONF,
EM, FCOE, FCPD, FCPH, FCR, FICON,
FICU, FLOD, FSPF, FSSM, FW,
HAM,,HAMK, HIL, IPS, ISNS, L2SYS,
MFIC, PDM, PLAT, PORT, RCS, RPCD,
RTWR, SEC, SNMP, SWCH, TRCE, TRCK,
WEBD, ZONE.
-Added new messages to AG, AN, AUTH,
BLS, C2, CDR, CEE, CONFIG, CHASSIS,
CNM, CONF, CTAP, CVLC, CVLM, DAUTH,
EM, FABR, FCIP, FCPH, FCR, FICON, FICU,
FSPF, FSS, FW, HAM, HSL, KAC, KSWD,
LANCE, LFM, MS, NS, NSM, PMGR, PORT,
PSWP, RKD, SEC, SPC, SPM, SS, SULB,
SWCH, TAPE, UCST, UPTH, XTUN, ZONE.
-Added new chapters for LANCE, BLS, AN,
CVLM, DAUTH, XTUN.
-Updated Introductory chapters.
July 2009
Fabric OS Message Reference
53-1001338-02
Updated for Fabric OS v6.3.0 patch:
-Modified a message to BL.
-Added new messages to AG, BL, and
FCOE.
-Added new chapters for Audit CNM,
Audit CVLM, and Audit SPM.
November 2009
Fabric OS Message Reference
53-1001767-01
Updated for Fabric OS v6.4.0:
-Modified messages to FICU and FW.
-Deleted messages to BL, FCOE and FW.
-Added new messages to AG, AN, AUTH,
BL, C2, CNM, CONF, CVLC, CVLM, FABR,
FICU, FW, HAM, HIL, MQ, MS, MSTP, NS,
NSM, ONM, PS, PSWP, RKD, SEC, SPM,
SS, SSM, SULB, SWCH and ZONE.
-Updated Introductory chapters.
March 2010
Title
Publication
number
Summary of changes
Date
Fabric OS Message Reference
53-1002149-01
Updated for Fabric OS v7.0.0:
-Added new chapters: C3, CAL,
MCAST_SS, RTE, and VS.
-Added new messages: AG, AN, ANV, BL,
C2, CDR, CCFG, ECC, EM, ESS, FABR,
FCOE, FCPH, FICN, FICU, FSPF, FW, HIL,
IPAD, IPS, KAC, L2SYS, LACP, LOG, MS,
NS, NSM, ONM, PDM, PS, RAS, RCS,
SCN, SEC, SNMP, SPM, SS, SSM, SULB,
SWCH, XTUN, ZEUS, and ZONE.
-Modified messages: CDR, EM, FABR,
FCOE, FICU, FW, HIL, L2SYS, PMGR, SEC,
SPM, SS, and XTUN.
-Deleted messages: C2, FCOE, FICU, and
NSM.
-Added new Audit chapters: ESS, MS,
PMGR, and RAS.
-Updated Introductory chapter.
April 2011
Fabric OS Message Reference
53-1002448-01
Updated for Fabric OS v7.0.1:
-Added new messages: BL, CVLC, FICON,
FSPF, and PS
-Modified messages: AG, AN, C2, C3,
CDR, FABR, FSPF, L2SYS, NSM, RTE, and
ZONE.
-Deleted messages: EM, FABR, ISCS,
SAS, and ZOLB.
-Updated Introductory chapter.
December 2011
Fabric OS Message Reference
53-1002749-01
Updated for Fabric OS v7.1.0:
- Added new chapters: MM and VDR.
- Added new messages: AG, ANV, BL, C2,
C3, CDR, CONF, CVLM, EM, FABR, FCR,
FSPF, FW, HAM, HIL, KAC, LOG, MS,
NBFS, PLAT, PS, RAS, SEC, SS, SWCH,
TRCE, VDR, XTUN, ZEUS, and ZONE.
- Modified messages: AN, AUTH, BL, C2,
C3, CDR, CAL, CNM, DOT1, FABR, FCOE,
FCPD, FCR, FICU, FSPF, FSS, HIL, HSL,
HTTP, IPS, KTRC, L2SS, LFM, PMGR, PS,
RCS, RTWR, SEC, ZONE.
- Deleted messages: EM, FCOE, HAM,
SNMP, SYSC, UCST, ZONE.
- Deleted modules: BLL, CER, FCIP, IBPD,
and ICPD.
- Updated Introductory chapter.
December 2012
Title
Publication
number
Summary of changes
Date
Fabric OS Message Reference
vii
53-1002749-01
Contents
About This Document
How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
What’s new in this document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv
Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xvii
Text formatting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii
Command syntax conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii
Command examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii
Notes, cautions, and warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xviii
Key terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
Notice to the reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
Brocade resources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
Other industry resources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
Getting technical help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xx
Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxi
Chapter 1
Introduction to System Messages
Overview of system messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
System message types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Message severity levels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
System error message logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Configuring the syslog message destinations. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
System logging daemon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
System console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SNMP trap recipient. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SNMP inform recipient. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Port logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Changing the severity level of swEventTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Commands for displaying and configuring the system message logs. . . . . . . .13
Displaying message content on switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Fabric OS Message Reference
53-1002749-01
Configuring system messages and attributes. . . . . . . . . . . . . . . . . . . . . . . . . . .15
Configuring event auditing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Disabling a RASLog message or module . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Enabling a RASLog message or module. . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Setting the severity level of a RASLog message . . . . . . . . . . . . . . . . . . . . . 17
Displaying system message logs and attributes. . . . . . . . . . . . . . . . . . . . . . . . . 17
Displaying RASLog messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Displaying RASLog messages one message at a time . . . . . . . . . . . . . . . .18
Displaying Audit messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Displaying FFDC messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Displaying status of the system messages . . . . . . . . . . . . . . . . . . . . . . . . .20
Displaying the severity level of RASLog messages . . . . . . . . . . . . . . . . . . .20
Displaying RASLog messages by severity level . . . . . . . . . . . . . . . . . . . . . .21
Displaying RASLog messages by message ID . . . . . . . . . . . . . . . . . . . . . . .21
Displaying messages on a slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Viewing RASLog messages from Web Tools. . . . . . . . . . . . . . . . . . . . . . . . .22
Clearing the system message logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Clearing the system message log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Clearing the Audit message log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Reading the system messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Reading a RAS system message. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Reading an Audit message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Responding to a system message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Looking up a system message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Gathering information about the problem . . . . . . . . . . . . . . . . . . . . . . . . . .26
Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
System module descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Chapter 2
Log Messages
Chapter 3
Audit Messages
Chapter 4
FFDC Messages
Chapter 5
Fabric OS System Messages
AG Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121
AN Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .136
ANV Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140
Fabric OS Message Reference
ix
53-1002749-01
AUTH Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144
BKSW Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162
BL Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163
BLS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180
BM Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182
C2 Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187
C3 Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194
CAL Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .202
CCFG Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203
CDR Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .207
CHS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214
CNM Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216
CONF Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .239
CTAP Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244
CVLC Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245
CVLM Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .258
DOT1 Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273
ECC Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .277
EM Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .278
ESS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .297
ESW Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .300
EVMD Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .303
FABR Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .304
FABS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .321
FBC Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .326
FCMC Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327
FCOE Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .328
FCPD Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .341
FCPH Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .343
FCR Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .345
FICN Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374
FICU Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .418
FKLB Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .425
FLOD Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .426
FSPF Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .428
FSS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .432
FSSM Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .436
Fabric OS Message Reference
53-1002749-01
FW Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .438
HAM Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .541
HAMK Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .546
HIL Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .548
HLO Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .565
HMON Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .567
HSL Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .568
HTTP Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .571
IBD Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .572
IPAD Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .573
IPS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .575
ISNS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .578
KAC Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .582
KSWD Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .587
KTRC Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .588
L2SS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .590
L3SS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .593
LACP Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .594
LANCE Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .595
LFM Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .596
LOG Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .598
LSDB Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .602
MCAST_SS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .604
MFIC Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .611
MM Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .613
MPTH Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .614
MQ Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .615
MS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .617
MSTP Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .624
NBFS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .627
NS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .629
NSM Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .633
ONMD Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .640
PDM Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .642
PDTR Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .650
PLAT Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .651
PMGR Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .653
Fabric OS Message Reference
xi
53-1002749-01
PORT Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .657
PS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .660
PSWP Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .664
RAS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .667
RCS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .672
RKD Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .677
RMON Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .679
RPCD Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .680
RTE Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .683
RTWR Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .684
SCN Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .686
SEC Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .688
SFLO Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .771
SNMP Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 774
SPC Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .777
SPM Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .790
SS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .805
SSMD Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .810
SULB Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .825
SWCH Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .843
SYSC Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .852
SYSM Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .854
TAPE Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .857
TRCE Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .858
TRCK Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .863
TS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .865
UCST Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .868
UPTH Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .871
VDR Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .872
VS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .873
WEBD Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .876
XTUN Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .879
ZEUS Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .889
ZONE Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .892
Fabric OS Message Reference
xiii
53-1002749-01
About This Document
In this chapter
•How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
•Supported hardware and software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
•What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv
•Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvii
•Notice to the reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
•Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix
•Getting technical help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xx
•Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxi
How this document is organized
This document is organized to help you find the information that you want as quickly and easily as
possible.
The document contains the following components:
•
Chapter 1, “Introduction to System Messages” provides basic information on system
messages.
•
Chapter 2, “Log Messages” includes a lookup list for LOG messages.
•
Chapter 3, “Audit Messages” includes a lookup list for Audit messages.
•
Chapter 4, “FFDC Messages” includes a lookup list for FFDC messages.
•
Chapter 5, “Fabric OS System Messages” provides message text, probable cause,
recommended action, and severity for each of the messages.
Supported hardware and software
In those instances in which procedures or parts of procedures documented here apply to some
switches but not to others, this guide identifies exactly which switches are supported and which are
not.
Although many different software and hardware configurations are tested and supported by
Brocade Communications Systems, Inc. for Fabric OS v7.1.0, documenting all possible
configurations and scenarios is beyond the scope of this document.
Fabric OS Message Reference
53-1002749-01
The following hardware platforms are supported by this release of Fabric OS:
•
Brocade 300
•
Brocade 5100
•
Brocade 5300
•
Brocade 5410
•
Brocade 5424
•
Brocade 5430
•
Brocade 5450
•
Brocade 5460
•
Brocade 5470
•
Brocade 5480
•
Brocade 6505
•
Brocade 6510
•
Brocade 6520
•
Brocade 7800
•
Brocade 8000
•
Brocade Encryption Switch
•
Brocade DCX Backbone and Brocade DCX-4S Backbone
-
FC8-16 port blade
-
FC8-32 port blade
-
FC8-48 port blade
-
FC8-64 port blade
-
FCOE10-24 DCX Blade
-
FS8-18 Encryption Blade
-
FX8-24 DCX Extension Blade
•
Brocade DCX 8510-8 Backbone and Brocade DCX 8510-4 Backbone
-
FC8-32E port blade
-
FC8-48E port blade
-
FC8-64 port blade
-
FC16-32 port blade
-
FC16-48 port blade
-
FS8-18 Encryption Blade
-
FX8-24 DCX Extension Blade
•
Brocade VA-40FC
Fabric OS Message Reference
xv
53-1002749-01
What’s new in this document
The following changes have been made since this document was last released:
•
The lookup lists in Chapter 2 through Chapter 4 provide hyperlinks to messages by type (LOG,
Audit, and FFDC).
•
Information that was added:
-
AG Messages
-
ANV Messages
-
BL Messages
-
C2 Messages
-
C3 Messages
-
CDR Messages
-
CONF Messages
-
CVLM Messages
-
EM Messages
-
FABR Messages
-
FCR Messages
-
FSPF Messages
-
FW Messages
-
HAM Messages
-
HIL Messages
-
KAC Messages
-
LOG Messages
-
MM Messages
-
MS Messages
-
NBFS Messages
-
PLAT Messages
-
PS Messages
-
RAS Messages
-
SEC Messages
-
SS Messages
-
SWCH Messages
-
TRCE Messages
-
VDR Messages
-
XTUN Messages
-
ZEUS Messages
-
ZONE Messages
Fabric OS Message Reference
53-1002749-01
•
Information that was changed:
-
AN Messages
-
AUTH Messages
-
BL Messages
-
C2 Messages
-
C3 Messages
-
CDR Messages
-
CAL Messages
-
CNM Messages
-
DOT1 Messages
-
FABR Messages
-
FCOE Messages
-
FCPD Messages
-
FCR Messages
-
FICU Messages
-
FSPF Messages
-
FSS Messages
-
HIL Messages
-
HSL Messages
-
HTTP Messages
-
IPS Messages
-
KAC Messages
-
KTRC Messages
-
L2SS Messages
-
LFM Messages
-
PMGR Messages
-
PS Messages
-
RCS Messages
-
RTWR Messages
-
SEC Messages
-
ZONE Messages
Fabric OS Message Reference
xvii
53-1002749-01
•
Information that was deleted:
-
BLL System Messages
-
CER System Messages
-
EM Messages
-
FCIP System Messages
-
FCOE Messages
-
HAM Messages
-
IBPD System Messages
-
ICPD System Messages
-
SNMP Messages
-
SYSC Messages
-
UCST Messages
-
ZONE Messages
For further information about new features and documentation updates for this release, refer to
the release notes.
Document conventions
This section describes text formatting conventions and important notice formats used in this
document.
Text formatting
The narrative-text formatting conventions that are used are as follows:
bold text
Identifies command names
Identifies the names of user-manipulated GUI elements
Identifies keywords and operands
Identifies text to enter at the GUI or CLI
italic text
Provides emphasis
Identifies variables
Identifies paths and Internet addresses
Identifies document titles
code text
Identifies CLI output
Identifies command syntax examples
For readability, command names in the narrative portions of this guide are presented in mixed
lettercase: for example, switchShow. In actual examples, command lettercase is all lowercase.
Command syntax conventions
Command syntax in this manual follows these conventions:
Fabric OS Message Reference
53-1002749-01
Command examples
This book describes how to perform configuration tasks using the Fabric OS command line
interface, but does not describe the commands in detail. For complete descriptions of all Fabric OS
commands, including syntax, operand description, and sample output, see the Fabric OS
Command Reference.
Notes, cautions, and warnings
The following notices and statements are used in this manual. They are listed below in order of
increasing severity of potential hazards.
NOTE
A note provides a tip, guidance, or advice, emphasizes important information, or provides a
reference to related information.
ATTENTION
An Attention statement indicates potential damage to hardware or data.
CAUTION
A Caution statement alerts you to situations that can be potentially hazardous to you or cause
damage to hardware, firmware, software, or data.
DANGER
A Danger statement indicates conditions or situations that can be potentially lethal or extremely
hazardous to you. Safety labels are also attached directly to products to warn of these conditions
or situations.
command
Commands are printed in bold.
--option, option
Command options are printed in bold.
-argument, arg
Arguments.
[ ]
Optional element.
variable
Variables are printed in italics. In the help pages, values are underlined or
enclosed in angled brackets < >.
...
Repeat the previous element, for example “member[;member...]”
value
Fixed values following arguments are printed in plain font. For example,
--show WWN
|
Boolean. Elements are exclusive. Example: --show -mode egress | ingress
Fabric OS Message Reference
xix
53-1002749-01
Key terms
For definitions specific to Brocade and Fibre Channel, see the technical glossaries on MyBrocade.
See “Brocade resources” on page xix for instructions on accessing MyBrocade.
For definitions of SAN-specific terms, visit the Storage Networking Industry Association online
dictionary at:
http://www.snia.org/education/dictionary
Notice to the reader
This document may contain references to the trademarks of the following corporations. These
trademarks are the properties of their respective companies and corporations.
These references are made for informational purposes only.
Additional information
This section lists additional Brocade and industry-specific documentation that you might find
helpful.
Brocade resources
To get up-to-the-minute information, go to http://my.brocade.com to register at no cost for a user ID
and password.
White papers, online demonstrations, and data sheets are available through the Brocade website
at:
http://www.brocade.com/products-solutions/products/index.page
For additional Brocade documentation, visit the Brocade website:
http://www.brocade.com
Release notes are available on the MyBrocade website.
Other industry resources
For additional resource information, visit the Technical Committee T11 website. This website
provides interface standards for high-performance and mass storage applications for Fibre
Channel, storage management, and other applications:
http://www.t11.org
Corporation
Referenced Trademarks and Products
Red Hat, Inc.
Red Hat, Red Hat Network, Maximum RPM, Linux Undercover
Fabric OS Message Reference
53-1002749-01
For information about the Fibre Channel industry, visit the Fibre Channel Industry Association
website:
http://www.fibrechannel.org
Getting technical help
Contact your switch support supplier for hardware, firmware, and software support, including
product repairs and part ordering. To expedite your call, have the following information available:
1.
General Information
•
Switch model
•
Switch operating system version
•
Software name and software version, if applicable
•
Error numbers and messages received
•
supportSave command output
•
Detailed description of the problem, including the switch or fabric behavior immediately
following the problem, and specific questions
•
Description of any troubleshooting steps already performed and the results
•
Serial console and Telnet session logs
•
syslog message logs
2.
Switch Serial Number
The switch serial number and corresponding bar code are provided on the serial number label,
as illustrated below.
The serial number label is located as follows:
•
Brocade 300, 5100, 5300, 6505, 6510, 6520, 7800, 8000, VA-40FC, and Brocade
Encryption Switch—On the switch ID pull-out tab located inside the chassis on the port side
on the left.
•
Brocade 5410, 5424, 5430, 5450, 5460, 5470, 5480—Serial number label attached to
the module.
•
Brocade DCX and DCX 8510-8—On the port side of the chassis, on the lower right side and
directly above the cable management comb.
•
Brocade DCX-4S and DCX 8510-4—On the non-port side of the chassis, on the lower left
side.
3.
World Wide Name (WWN)
Use the licenseIdShow command to display the WWN of the chassis.
Fabric OS Message Reference
xxi
53-1002749-01
If you cannot use the licenseIdShow command because the switch is inoperable, you can get
the WWN from the same place as the serial number, except for the Brocade DCX. For the
Brocade DCX, access the numbers on the WWN cards by removing the Brocade logo plate at
the top of the non-port side of the chassis.
Document feedback
Quality is our first concern at Brocade and we have made every effort to ensure the accuracy and
completeness of this document. However, if you find an error or an omission, or you think that a
topic needs further development, we want to hear from you. Forward your feedback to:
[email protected]
Provide the title and version number of the document and as much detail as possible about your
comment, including the topic heading and page number and your suggestions for improvement.
Fabric OS Message Reference
1
53-1002749-01
Chapter
1
Introduction to System Messages
In this chapter
•Overview of system messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
•Configuring the syslog message destinations. . . . . . . . . . . . . . . . . . . . . . . . . 5
•Changing the severity level of swEventTrap. . . . . . . . . . . . . . . . . . . . . . . . . . 11
•Commands for displaying and configuring the system message logs. . . . . 13
•Displaying message content on switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
•Configuring system messages and attributes . . . . . . . . . . . . . . . . . . . . . . . . 15
•Displaying system message logs and attributes . . . . . . . . . . . . . . . . . . . . . . 17
•Clearing the system message logs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
•Reading the system messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
•Responding to a system message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
•System module descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Overview of system messages
This guide supports Fabric OS v7.1.0 and documents system messages that can help you diagnose
and fix problems with a switch or fabric. The messages are organized alphabetically by module
name. A module is a subsystem in the Fabric OS. Each module generates a set of numbered
messages. For each message, this guide provides message text, probable cause, recommended
action, and severity level. There may be more than one cause and more than one recommended
action for any given message. This guide discusses the most probable cause and typical action
recommended.
System message types
Fabric OS supports three types of system messages. A system message can be of one or more of
the following types:
•
RASLog messages
•
Audit log messages
•
FFDC messages
Fabric OS supports a different methodology for storing and accessing each type of message.
Fabric OS Message Reference
53-1002749-01
Overview of system messages
1
RASLog messages
RASLog messages report significant system events (failure, error, or critical conditions) or
information and are also used to show the status of the high-level user-initiated actions. RASLog
messages are forwarded to the console, to the configured syslog servers, and to the SNMP
management station through the Simple Network Management Protocol (SNMP) traps or informs.
The following is an example of a RASLog system message.
2012/10/25-17:51:05, [C3-1001], 937, CHASSIS, ERROR, switch, Port 18 failed due to
SFP validation failure. Check if the SFP is valid for the configuration.
For information on displaying and clearing the RASLog messages, refer to “Displaying system
message logs and attributes” on page 17.
Audit log messages
Event auditing is designed to support post-event audits and problem determination based on
high-frequency events of certain types such as security violations, zoning configuration changes,
firmware downloads, and certain types of fabric events. Audit messages flagged as AUDIT are not
saved in the switch error logs. The switch can be configured to stream Audit messages to the switch
console and to forward the messages to specified syslog servers. The Audit log messages are not
forwarded to an SNMP management station. There is no limit to the number of audit events.
The following is an example of an Audit message.
0 AUDIT, 2012/10/14-06:07:33 (UTC), [SULB-1003], INFO, FIRMWARE,
admin/admin/192.0.2.2/telnet/CLI ad_0/switch, , Firmwarecommit has started.
For any given event, Audit messages capture the following information:
•
User Name - The name of the user who triggered the action.
•
User Role - The access level of the user, such as root or admin.
•
Event Name - The name of the event that occurred.
•
Event Information - Information about the event.
The seven event classes described in Table 1 can be audited.
TABLE 1
Event classes
Operand
Event class
Description
1
Zone
You can audit zone event configuration changes, but not the actual
values that were changed. For example, you may receive a message
that states “Zone configuration has changed,” but the message
does not display the actual values that were changed.
2
Security
You can audit any user-initiated security event for all management
interfaces. For events that have an impact on the entire fabric, an
audit is only generated for the switch from which the event was
initiated.
3
Configuration
You can audit configuration downloads of existing SNMP
configuration parameters. Configuration uploads are not audited.
4
Firmware
You can audit configuration downloads of existing SNMP
configuration parameters. Configuration uploads are not audited.
5
Fabric
You can audit Administration Domain-related changes.
Fabric OS Message Reference
3
53-1002749-01
Overview of system messages
1
Fabric OS v7.1.0 generates component-specific Audit messages.
Event auditing is a configurable feature, which is by default disabled. You must enable event
auditing using the auditCfg --enable command to send the events to a configured remote host.
Syslogd must be configured for logging audit messages. You can set up filters to screen out
particular classes of events using the auditCfg command. The defined set of Audit messages is
sent to the configured remote host in the Audit message format, so that they are easily
distinguishable from other syslog events that may occur in the network. For details on how to
configure event auditing, refer to “Configuring event auditing” on page 15.
FFDC messages
First Failure Data Capture (FFDC) is used to capture failure-specific data when a problem or failure
is noted for the first time and before the switch reboots, or trace and log buffer get wrapped. All
subsequent iterations of the same error are ignored. This critical debug information is saved in
nonvolatile storage and can be retrieved using the supportSave command. The FFDC data is used
for debugging or analyzing the problem. FFDC is intended for use by Brocade technical support.
FFDC is enabled by default. Execute the supportFfdc command to enable or disable FFDC. If FFDC
is disabled, the FFDC daemon does not capture any data, even when a message with an FFDC
attribute is logged.
The following is an example of the FFDC message.
2000/12/17-08:30:13, [SS-1000], 88, SLOT 6 | FFDC | CHASSIS, INFO, DCX,
supportSave has uploaded support information to the host with IP address
192.0.2.2.
Message severity levels
Table 2 shows the four levels of severity for system messages, ranging from CRITICAL (1) to INFO
(4). In general, the definitions are wide ranging and are to be used as general guidelines for
troubleshooting. For all cases, you must look at each specific error message description thoroughly
before taking action.
6
FW
You can audit Fabric Watch (FW)-related changes.
7
LS
You can audit Virtual Fabric (Logical Switch)-related changes.
8
CLI
You can audit the CLI commands executed on the switch.
N/A
RAS
Used to audit or track the RASLog messages or modules that are
enabled or disabled using the rasAdmin command.
NOTE: The RAS class is not configurable, and it is always enabled
internally.
TABLE 1
Event classes (Continued)
Operand
Event class
Description
Fabric OS Message Reference
53-1002749-01
Overview of system messages
1
System error message logging
The RASLog service generates and stores messages related to abnormal or erroneous system
behavior. It includes the following features:
•
All RASLog error messages are saved to nonvolatile storage by default.
•
The system error message log can save a maximum of 1024 messages in random access
memory (RAM).
•
The system message log is implemented as a circular buffer. When more than the maximum
entries are added to the log file, old entries are overwritten by new entries.
•
Messages are numbered sequentially from 1 to 2,147,483,647 (0x7ffffff). The sequence
number will continue to increase beyond the storage limit of 1024 messages. The sequence
number can be reset to 1 using the errClear command. The sequence number is persistent
across power cycles and switch reboots.
•
Trace dump, FFDC, and core dump files can be uploaded to the FTP server using the
supportSave command.
•
Brocade recommends that you configure the syslogd facility as a management tool for error
logs. This is particularly important for dual-domain switches because the syslogd facility saves
messages from two logical switches as a single file and in sequential order. For more
information, refer to “System logging daemon” on page 5.
•
RASLog messages are streamed to the console, and are forwarded to the configured syslog
servers and to the SNMP management station through the SNMP traps (in SNMPv1 and
SNMPv3) or informs (in SNMPv3). Use the snmpConfig command to configure the SNMPv1
and SNMPv3 hosts and their configurations.
•
Audit messages are streamed to the switch console, and are forwarded to the configured
syslog servers. The Audit log messages are not forwarded to an SNMP management station.
TABLE 2
Severity levels of a message
Severity level
Description
1 = CRITICAL
Critical-level messages indicate that the software has detected serious problems that
will cause a partial or complete failure of a subsystem if not corrected immediately; for
example, a power supply failure or rise in temperature must receive immediate
attention.
2 = ERROR
Error-level messages represent an error condition that does not impact overall system
functionality significantly. For example, error-level messages might indicate time-outs
on certain operations, failures of certain operations after retries, invalid parameters, or
failure to perform a requested operation.
3 = WARNING
Warning-level messages highlight a current operating condition that should be
checked or it may lead to a failure in the future. For example, a power supply failure in
a redundant system relays a warning that the system is no longer operating in
redundant mode unless the failed power supply is replaced or fixed.
4 = INFO
Info-level messages report the current non-error status of the system components: for
example, detecting online and offline status of a fabric port.
Fabric OS Message Reference
5
53-1002749-01
Configuring the syslog message destinations
1
Configuring the syslog message destinations
You can configure the Fabric OS to send the syslog messages to the following output locations:
syslog daemon, system console, and SNMP management station.
System logging daemon
The system logging daemon (syslogd) is a process on UNIX, Linux, and some Windows systems that
reads and logs messages as specified by the system administrator.
Fabric OS can be configured to use a UNIX-style syslogd process to forward system events and error
messages to log files on a remote host system. The host system can be running UNIX, Linux, or any
other operating system that supports the standard syslogd functionality. Configuring for syslogd
involves configuring the host, enabling syslogd on the Brocade model, and, optionally, setting the
facility level.
For the Brocade DCX family of switches, each control processor (CP) has a unique error log,
depending on which CP was active when that message was reported. To fully understand message
logging, you should enable the syslogd, because the logs on the host computer are maintained in a
single merged file for both CPs and are in sequential order. Otherwise, you must examine the error
logs in both CPs, particularly for events such as firmwareDownload or haFailover, for which the
active CP changes.
For the Brocade DCX family of switches, any security violations that occur through Telnet, HTTP, or
serial connections are not propagated between CPs. Security violations on the active CP are not
propagated to the standby CP counters in the event of a failover, nor do security violations on the
standby CP get propagated to the active CP counters.
Configuring a syslog server
To configure the switch to forward all system events and error messages to the syslogd of one or
more servers, perform the following steps.
1.
Log in to the switch as admin.
2.
Execute the syslogdIpAdd IP address command to add a server to which system messages are
forwarded.
switch:admin> syslogdipadd 192.0.2.2
You can configure up to six syslog servers to receive the syslog messages.
3.
Execute the syslogdIpShow command to verify the syslog configuration on the switch.
switch:admin> syslogdipshow
syslog.1 192.0.2.2
You can remove a configured syslog server using the syslogdIpRemove IP address command.
System console
The system console displays RASLog messages, Audit messages (if enabled), and panic dump
messages. These messages are mirrored to the system console; they are always saved in one of
the system logs.
Fabric OS Message Reference
53-1002749-01
Configuring the syslog message destinations
1
The system console displays messages only through the serial port. If you log in to a switch through
the Ethernet port or modem port, you will not receive system console messages.
You can filter messages that display on the system console by severity using the errFilterSet
command. All messages are still sent to the system message log and syslogd (if configured).
Setting the system console severity level
You can limit the types of messages that are logged to the console using the errFilterSet command.
The system messages displayed on the console are filtered up to and include the configured
severity level. You can choose one of the following severity levels: INFO, WARNING, ERROR, or
CRITICAL.
To set the severity levels for the system console, perform the following steps.
1.
Log in to the switch as admin.
2.
Execute the errFilterSet [-d console -v severity] command to set the console severity level. The
severity can be one of the following: INFO, WARNING, ERROR, or CRITICAL. The severity values
are not case-sensitive.
For example, to set the filter severity level for the console to ERROR, enter the following
command.
switch:admin> errfilterset -d console -v error
3.
Execute the errFilterSet command to verify the configured filter settings.
switch:admin> errfilterset
console: filter severity = ERROR
SNMP trap recipient
An unsolicited message that comes to the management station from the SNMP agent on the
device is called a trap. When an event occurs and if the event severity level is at or below the set
severity level, the SNMP trap, swEventTrap, is sent to the configured trap recipients. The VarBind in
the Trap Data Unit contains the corresponding instance of the event index, time information, event
severity level, the repeat count, and description. The following are the possible severity levels:
•
None (0)
•
Critical (1)
•
Error (2)
•
Warning (3)
•
Informational (4)
•
Debug (5)
By default, the severity level is set to None, implying all traps are filtered and therefore no event
traps are received. When the severity level is set to Informational, all traps with the severity level of
Informational, Warning, Error, and Critical are received. For more information on changing the
severity level of swEventTrap, refer to “Changing the severity level of swEventTrap” on page 11.
NOTE
The Audit messages are not converted into swEventTrap.
Fabric OS Message Reference
7
53-1002749-01
Configuring the syslog message destinations
1
The SNMP traps are unreliable because the trap recipient does not send any acknowledgment
when it receives a trap. Therefore, the SNMP agent cannot determine if the trap was received.
Brocade switches send traps out on UDP port 162. To receive traps, the management station IP
address must be configured on the switch. You can configure the SNMPv1 and SNMPv3 hosts to
receive the traps.
For more information on the swEventTrap, refer to the Fabric OS MIB Reference.
Configuring the SNMPv1 trap recipient
Use the snmpConfig --set snmpv1 command to specify the recipient of the SNMP trap. To
configure the SNMPv1 host to receive the trap, perform the following steps.
1.
Log in to the switch as admin.
2.
Execute the snmpConfig --set snmpv1 command to configure the SNMP trap recipient.
switch:admin> snmpconfig --set snmpv1
SNMP community and trap recipient configuration:
Community (rw): [Secret C0de]
Trap Recipient's IP address : [192.0.2.2]
Trap recipient Severity level : (0..5) [4]
Trap recipient Port : (0..65535) [162]
Community (rw): [OrigEquipMfr]
Trap Recipient's IP address : [fec0:60:22bc:200:313:72ff:fe64:78b2]
NOTE
To receive the traps, the management station IP address must be configured on the switch.
3.
Execute the snmpConfig --show snmpv1 command to verify the SNMPv1 agent configuration.
switch:admin> snmpconfig --show snmpv1
SNMPv1 community and trap recipient configuration:
Community 1: Secret C0de (rw)
Trap recipient: 192.0.2.2
Trap port: 162
Trap recipient Severity level: 5
Community 2: OrigEquipMfr (rw)
Trap recipient: fec0:60:22bc:200:313:72ff:fe64:78b2
Trap port: 162
Trap recipient Severity level: 5
Community 3: private (rw)
Trap recipient: tools.lab.brocade.com
Trap port: 162
Trap recipient Severity level: 5
Community 4: public (ro)
Trap recipient: 192.0.10.10
Trap port: 65530
Trap recipient Severity level: 1
Community 5: common (ro)
Trap recipient: fec0:60:69bc:200:213:72ff:fe64:069f
Trap port: 11
Trap recipient Severity level: 2
Community 6: FibreChannel (ro)
Trap recipient: WT.org.brocade.com
Trap port: 65521
Fabric OS Message Reference
53-1002749-01
Configuring the syslog message destinations
1
Trap recipient Severity level: 2
SNMPv1:Enabled
Configuring the SNMPv3 trap recipient
To configure the SNMPv3 host to receive the trap, perform the following steps.
1.
Log in to the switch as admin.
2.
Execute the snmpConfig --set snmpv3 command to configure the SNMP trap recipient. Ignore
the step to enable the SNMP informs “SNMP Informs Enabled”.
switch:admin> snmpconfig --set snmpv3
SNMP Informs Enabled (true, t, false, f): [false]
SNMPv3 user configuration(snmp user not configured in FOS user database will
have physical AD and admin role as the default):
User (rw): [snmpadmin1]
Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) [3]
Priv Protocol [DES(1)/noPriv(2)/3DES(3)/AES128(4)/AES192(5)/AES256(6)]):
(2..2) [2]
User (rw): [snmpadmin2]
Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) [3]
Priv Protocol [DES(1)/noPriv(2)/3DES(3)/AES128(4)/AES192(5)/AES256(6)]):
(2..2) [2]
User (rw): [snmpadmin3]
Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) [3]
Priv Protocol [DES(1)/noPriv(2)/3DES(3)/AES128(4)/AES192(5)/AES256(6)]):
(2..2) [2]
User (ro): [snmpuser1]
Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) [3]
Priv Protocol [DES(1)/noPriv(2)/3DES(3)/AES128(4)/AES192(5)/AES256(6)]):
(2..2) [2]
User (ro): [snmpuser2]
Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) [3]
Priv Protocol [DES(1)/noPriv(2)/3DES(3)/AES128(4)/AES192(5)/AES256(6)]):
(2..2) [2]
User (ro): [snmpuser3]
Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) [3]
Priv Protocol [DES(1)/noPriv(2)/3DES(3)/AES128(4)/AES192(5)/AES256(6)]):
(2..2) [2]
SNMPv3 trap recipient configuration:
Trap Recipient's IP address : [192.0.2.2]
UserIndex: (1..6) [1]
Trap recipient Severity level : (0..5) [1]
Trap recipient Port : (0..65535) [35432]
Trap Recipient's IP address : [192.0.10.10]
UserIndex: (1..6) [2]
Trap recipient Severity level : (0..5) [5]
Trap recipient Port : (0..65535) [162]
Trap Recipient's IP address : [192.0.20.20]
[...]
NOTE
To receive the SNMP traps, the username, the authentication protocol, the UDP port number,
and the privacy protocol must match between the switch and the management station.
Fabric OS Message Reference
9
53-1002749-01
Configuring the syslog message destinations
1
3.
Execute the snmpConfig --show snmpv3 command to verify the SNMP agent configuration.
switch:admin> snmpconfig --show snmpv3
SNMP Informs = 0 (OFF)
SNMPv3 USM configuration:
User 1 (rw): snmpadmin1
Auth Protocol: noAuth
Priv Protocol: noPriv
User 2 (rw): snmpadmin2
Auth Protocol: MD5
Priv Protocol: noPriv
User 3 (rw): snmpadmin3
Auth Protocol: MD5
Priv Protocol: DES
User 4 (ro): snmpuser1
Auth Protocol: noAuth
Priv Protocol: noPriv
User 5 (ro): snmpuser2
Auth Protocol: noAuth
Priv Protocol: noPriv
User 6 (ro): snmpuser3
Auth Protocol: noAuth
Priv Protocol: noPriv
SNMPv3 Trap configuration:
Trap Entry 1: 192.0.2.2
Trap Port: 162
Trap User: snmpadmin1
Trap recipient Severity level: 1
Trap Entry 2: fe80::224:1dff:fef6:0f21
Trap Port: 162
[...]
SNMP inform recipient
An SNMP inform is similar to the SNMP trap except that the management station that receives an
SNMP inform acknowledges the system message with an SNMP response packet data unit (PDU).
If the sender does not receive the SNMP response PDU, the inform request can be sent again. An
SNMP inform request is saved in the switch memory until a response is received or the request
times out. The informs are more reliable and they consume more resources in the device and in the
network. Use SNMP informs only if it is important that the management station receives all event
notifications. Otherwise, use the SNMP traps. Brocade devices support SNMPv3 informs.
Configuring the SNMPv3 inform recipient
To configure the SNMPv3 host to receive the SNMP informs, perform the following steps.
1.
Log in to the switch as admin.
2.
Execute the snmpConfig --set snmpv3 command to configure the inform recipient. When
prompted to enable the SNMP informs, enter true or t. Informs are disabled by default.
switch:admin> snmpconfig --set snmpv3
SNMP Informs Enabled (true, t, false, f): [false] t
SNMPv3 user configuration(snmp user not configured in FOS user database will
have physical AD and admin role as the default):
User (rw): [snmpadmin1]
Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) [3]
Fabric OS Message Reference
53-1002749-01
Configuring the syslog message destinations
1
Priv Protocol [DES(1)/noPriv(2)/3DES(3)/AES128(4)/AES192(5)/AES256(6)]):
(2..2) [2]
Engine ID: [0:0:0:0:0:0:0:0:0]
User (rw): [snmpadmin2]
Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) [3] 1
New Auth Passwd:
Verify Auth Passwd:
Priv Protocol [DES(1)/noPriv(2)/3DES(3)/AES128(4)/AES192(5)/AES256(6)]):
(1..6) [2] 1
New Priv Passwd:
Verify Priv Passwd:
Engine ID: [0:0:0:0:0:0:0:0:0] 80:00:05:23:01:0A:23:34:1B
User (rw): [snmpadmin3]
Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) [3]
Priv Protocol [DES(1)/noPriv(2)/3DES(3)/AES128(4)/AES192(5)/AES256(6)]):
(2..2) [2]
Engine ID: [0:0:0:0:0:0:0:0:0]
User (ro): [snmpuser1]
Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) [3]
Priv Protocol [DES(1)/noPriv(2)/3DES(3)/AES128(4)/AES192(5)/AES256(6)]):
(2..2) [2]
Engine ID: [0:0:0:0:0:0:0:0:0]
User (ro): [snmpuser2]
Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) [3]
Priv Protocol [DES(1)/noPriv(2)/3DES(3)/AES128(4)/AES192(5)/AES256(6)]):
(2..2) [2]
Engine ID: [0:0:0:0:0:0:0:0:0]
User (ro): [snmpuser3]
Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) [3]
Priv Protocol [DES(1)/noPriv(2)/3DES(3)/AES128(4)/AES192(5)/AES256(6)]):
(2..2) [2]
Engine ID: [0:0:0:0:0:0:0:0:0]
SNMPv3 trap recipient configuration:
Trap Recipient's IP address : [0.0.0.0] 192.0.2.2
UserIndex: (1..6) [1]
Trap recipient Severity level : (0..5) [0] 4
Trap recipient Port : (0..65535) [162]
Trap Recipient's IP address : [0.0.0.0] 192.0.10.10
UserIndex: (1..6) [2]
Trap recipient Severity level : (0..5) [0] 4
Trap recipient Port : (0..65535) [162]
Trap Recipient's IP address : [0.0.0.0]
Trap Recipient's IP address : [0.0.0.0]
Trap Recipient's IP address : [0.0.0.0]
Trap Recipient's IP address : [0.0.0.0]
Committing configuration.....done.
NOTE
To receive the SNMP informs, the username, the authentication protocol, the privacy protocol,
the UDP port number, and the engine ID must match between the switch and the management
station.
3.
Execute the snmpConfig --show snmpv3 command to verify the SNMP agent configuration.
switch:admin> snmpconfig --show snmpv3
SNMP Informs = 1 (ON)
SNMPv3 USM configuration:
User 1 (rw): snmpadmin1
Auth Protocol: noAuth
Fabric OS Message Reference
11
53-1002749-01
Changing the severity level of swEventTrap
1
Priv Protocol: noPriv
Engine ID: 80:00:05:23:01:0a:23:34:21
User 2 (rw): snmpadmin2
Auth Protocol: MD5
Priv Protocol: DES
Engine ID: 80:00:05:23:01:0a:23:34:1b
User 3 (rw): snmpadmin3
Auth Protocol: noAuth
Priv Protocol: noPriv
Engine ID: 00:00:00:00:00:00:00:00:00
User 4 (ro): snmpuser1
Auth Protocol: noAuth
Priv Protocol: noPriv
Engine ID: 00:00:00:00:00:00:00:00:00
User 5 (ro): snmpuser2
Auth Protocol: noAuth
Priv Protocol: noPriv
Engine ID: 00:00:00:00:00:00:00:00:00
User 6 (ro): snmpuser3
Auth Protocol: noAuth
Priv Protocol: noPriv
Engine ID: 00:00:00:00:00:00:00:00:00
SNMPv3 Trap configuration:
Trap Entry 1: 192.0.2.2
Trap Port: 162
Trap User: snmpadmin1
Trap recipient Severity level: 4
Trap Entry 2: 192.0.10.10
Trap Port: 162
Trap User: snmpadmin2
Trap recipient Severity level: 4
Trap Entry 3: No trap recipient configured yet
Trap Entry 4: No trap recipient configured yet
Trap Entry 5: No trap recipient configured yet
Port logs
The Fabric OS maintains an internal log of all port activity. Each switch or logical switch maintains a
log file for each port. Port logs are circular buffers that can save up to 8000 entries per logical
switch. When the log is full, the newest log entries overwrite the oldest log entries. Port logs capture
switch-to-device, device-to-switch, switch-to-switch, some device A-to-device B, and control
information. Port logs are not persistent and are lost over power cycles and reboots.
Execute the portLogShow command to display the port logs for a particular port.
Execute the portLogEventShow command to display the specific events reported for each port.
Port log functionality is completely separate from the system message log. Port logs are typically
used to troubleshoot device connections.
Changing the severity level of swEventTrap
When an event occurs and if the event severity level is at or below the set severity level, the SNMP
trap, swEventTrap, is sent to the configured trap recipients. By default, the severity level is set at 0
(None), implying that all the event traps are sent. Use the snmpConfig --set mibCapability
command to modify the severity level of swEventTrap.
Fabric OS Message Reference
53-1002749-01
Changing the severity level of swEventTrap
1
To change the severity level of swEventTrap, perform the following steps.
1.
Log in to the switch as admin.
2.
Execute the snmpConfig --set mibCapability command to configure MIBs interactively. All the
supported MIBs and associated traps are displayed. You can change the DesiredSeverity for
swEventTrap to 1 (Critical), 2 (Error), 3 (Warning), or 4 (Informational). The default value is 0.
switch:admin> snmpconfig --set mibcapability
FE-MIB: YES
SW-MIB: YES
FA-MIB: YES
FICON-MIB: YES
HA-MIB: YES
FCIP-MIB: YES
ISCSI-MIB: YES
IF-MIB: YES
BD-MIB: YES
SW-TRAP: YES
swFault: YES
swSensorScn: YES
swFCPortScn: YES
swEventTrap: YES
DesiredSeverity:Informational
swFabricWatchTrap: YES
DesiredSeverity:None
swTrackChangesTrap: YES
swIPv6ChangeTrap: YES
swPmgrEventTrap: YES
swFabricReconfigTrap: YES
swFabricSegmentTrap: YES
swExtTrap: NO
swStateChangeTrap: NO
swPortMoveTrap: NO
swBrcdGenericTrap: YES
...
SW-TRAP (yes, y, no, n): [yes]
swFault (yes, y, no, n): [yes]
swSensorScn (yes, y, no, n): [yes]
swFCPortScn (yes, y, no, n): [yes]
swEventTrap (yes, y, no, n): [yes]
DesiredSeverity: (0..4) [4] 3
swFabricWatchTrap (yes, y, no, n): [yes]
DesiredSeverity: (0..4) [0] 2
swTrackChangesTrap (yes, y, no, n): [yes]
swIPv6ChangeTrap (yes, y, no, n): [yes]
swPmgrEventTrap (yes, y, no, n): [yes]
[...]
3.
Execute the snmpConfig --show mibCapability command to verify the severity level of
swEventTrap.
switch:admin> snmpconfig --show mibcapability
FE-MIB: YES
SW-MIB: YES
FA-MIB: YES
FICON-MIB: YES
HA-MIB: YES
FCIP-MIB: YES
ISCSI-MIB: YES
Fabric OS Message Reference
13
53-1002749-01
Commands for displaying and configuring the system message logs
1
IF-MIB: YES
BD-MIB: YES
SW-TRAP: YES
swFault: YES
swSensorScn: YES
swFCPortScn: YES
swEventTrap: YES
DesiredSeverity:Informational
swFabricWatchTrap: YES
DesiredSeverity:Critical
swTrackChangesTrap: YES
swIPv6ChangeTrap: YES
swPmgrEventTrap: YES
swFabricReconfigTrap: YES
[...]
Commands for displaying and configuring the system message logs
Table 3 describes commands that you can use to view or configure the system message logs. Most
commands require the admin access level. For detailed information on required access levels and
commands, refer to the Fabric OS Command Reference.
TABLE 3
Commands for viewing or configuring the system parameters and message logs
Command
Description
auditCfg
Configures the audit message log.
auditDump
Displays or clears the audit log.
errClear
Clears all error log messages for all switch instances on this control processor (CP).
errDelimiterSet
Sets the error log start and end delimiter for messages pushed to the console.
errDump
Displays the entire error log, without page breaks. Use the -r option to show the
messages in reverse order, from newest to oldest.
errFilterSet
Sets an error severity filter for the system console.
errModuleShow
Displays all the defined error log modules.
errShow
Displays the entire error log, with page breaks. Use the -r option to show the messages
in reverse order, from newest to oldest.
pdShow
Displays the contents of the panic dump and core dump files.
portErrShow
Displays the port error summary.
portLogClear
Clears the port log. If the port log is disabled, this command enables it.
portLogDisable
Disables the port log facility.
portLogDump
Displays the port log, without page breaks.
portLogDumpPort
Displays the port log of the specified port, without page breaks.
portLogEnable
Enables the port log facility.
portLogEventShow
Displays which port log events are currently being reported.
portLoginShow
Displays port logins.
portLogPdisc
Sets or clears the debug pdisc_flag.
portLogReset
Enables the port log facility.
Fabric OS Message Reference
53-1002749-01
Displaying message content on switch
1
Displaying message content on switch
Beginning with Fabric OS v7.1.0, you can view the message documentation such as the message
text, message type, class (for audit messages), message severity, cause, and action on the switch
console by using the rasMan message_ID command.
To display the message documentation on switch, perform the following steps.
1.
Log in to the switch as admin.
2.
Use the rasMan message_ID command to display the documentation of a message. The
message_ID values are case-sensitive.
portLogResize
Resizes the port log to the specified number of entries.
portLogShow
Displays the port log, with page breaks.
portLogShowPort
Displays the port log of the specified port, with page breaks.
portLogTypeDisable
Disables an event from reporting to the port log. Port log events are described by the
portLogEventShow command.
portLogTypeEnable
Enables an event to report to the port log. Port log events are described by the
portLogEventShow command.
rasAdmin
Used to enable or disable logging for selected messages or modules, to change the
default severity level for a specified message, and to display configured RASLog
message settings.
rasMan
Displays message documentation on switch.
setVerbose
Sets the verbose level of a particular module within the Fabric OS.
snmpConfig
Manages the SNMP agent configuration.
supportFfdc
Enables and disables FFDC.
supportFtp
Sets, clears, or displays support FTP parameters or a time interval to check the FTP
server.
supportSave
Collects RASLog, trace files, and supportShow (active CP only) information for the local
CP and then transfers the files to an FTP server. The operation can take several
minutes.
supportShow
Executes a list of diagnostic and error display commands. This output is used by your
switch service provider to diagnose and correct problems with the switch. The output
from this command is very long.
syslogdFacility
Changes the syslogd facility.
syslogdIpAdd
Adds an IP address as a recipient of system messages.
syslogdIpRemove
Removes an IP address as a recipient of system messages.
syslogdIpShow
Views the currently configured IP addresses that are recipients of system messages.
traceDump
Displays, initiates, or removes a Fabric OS module trace dump.
TABLE 3
Commands for viewing or configuring the system parameters and message logs (Continued)
Command
Description
Fabric OS Message Reference
15
53-1002749-01
Configuring system messages and attributes
1
For example, execute the following command to display the documentation for PS-1007.
switch:admin> rasman PS-1007
Log Messages PS-1007(7m)
MESSAGE
PS-1007 - Failed to add Fabricmode Top Talker on
domain=. .
MESSAGE TYPE
LOG
SEVERITY
WARNING
PROBABLE CAUSE
Indicates that FC Routing (FCR) is enabled on the specified
fabric.
RECOMMENDED ACTION
Top Talker cannot be installed on a fabric with FCR service
enabled. In case Top Talker must be installed on a fabric,
disable FCR using the fosconfig --disable fcr command.
Configuring system messages and attributes
This section provides information on configuring the system message logs and its attributes. All
admin-level commands mentioned in this section are used to enable or disable only the external
messages.
Configuring event auditing
To configure event auditing, perform the following steps.
1.
Log in to the switch as admin.
2.
Execute the auditCfg --enable command to enable the audit feature.
switch:admin> auditcfg --enable
Audit filter is enabled.
3.
Execute the auditCfg --class command to configure the event classes you want to audit.
switch:admin> auditcfg --class 1,2,3,4,5,6,7,8
Audit filter is configured.
NOTE
The class option 9 (MAPS) is for internal use only. The RAS class is not configurable, and it is
always enabled internally.
4.
Execute the auditCfg --severity severity level command if you want to set the Audit severity
level. By default, all messages are logged. When the severity is set, only messages with the
configured severity and higher are displayed. Valid values for severity level are INFO, WARNING,
ERROR, and CRITICAL
switch:admin> auditcfg --severity ERROR
Fabric OS Message Reference
53-1002749-01
Configuring system messages and attributes
1
5.
Execute the auditCfg --show command to verify the configuration.
switch:admin> auditcfg --show
Audit filter is enabled.
1-ZONE
2-SECURITY
3-CONFIGURATION
4-FIRMWARE
5-FABRIC
6-FW
7-LS
8-CLI
Severity level: ERROR
You must configure the syslog daemon to send the Audit events to a configured remote host using
the syslogdIpAdd command. For more information on configuring the syslog server, refer to
“Configuring a syslog server” on page 5.
Disabling a RASLog message or module
To disable a single RASLog message or all messages in a module, perform the following steps.
1.
Log in to the switch as admin.
2.
Use the following commands to disable a single RASLog message or all messages that belong
to a module:
•
Execute the rasadmin --disable -log messgae_ID command to disable a RASLog message.
For example, execute the following command to disable the BL-1001 message.
switch:admin> rasadmin --disable -log BL-1001
2012/07/20-13:30:41, [LOG-1005], 378, SLOT 4 | CHASSIS, INFO, switch, Log
message NSM-1009 has been disabled.
Use the rasadmin --show -log messgae_ID command to verify the status of the message.
•
Execute the rasadmin --disable -module module_ID command to disable all messages in a
module. For example, execute the following command to disable all messages that belong
to the BL module.
switch:admin> rasadmin --disable -module BL
2012/07/20-13:28:37, [LOG-1007], 375, SLOT 4 | CHASSIS, INFO, switch, Log
Module BL has been disabled.
Use the rasadmin --show -module module_ID command to verify the status of the
messages that belong to a module.
NOTE
You cannot disable Audit and FFDC messages using the rasAdmin command.
Fabric OS Message Reference
17
53-1002749-01
Displaying system message logs and attributes
1
Enabling a RASLog message or module
To enable a single RASLog message or all messages in a module that were previously disabled,
perform the following steps.
1.
Log in to the switch as admin.
2.
Use the following commands to enable a single RASLog message or all messages that belong
to a module:
•
Execute the rasadmin --enable -log messgae_ID command to enable a single RASLog
message that has been disabled.
For example, execute the following command to enable BL-1001 message that was
previously disabled.
switch:admin> rasadmin --enable -log BL-1001
2012/10/15-13:24:30, [LOG-1006], 373, SLOT 4 | CHASSIS, INFO, switch, Log
message BL-1001 has been enabled.
Use the rasadmin --show -log messgae_ID command to verify the status of the message.
•
Execute the rasadmin --enable -module module_ID command to enable all messages in a
module. For example, execute the following command to enable to all previously disabled
BL messages.
switch:admin> rasadmin --enable -module BL
2012/10/15-13:28:37, [LOG-1007], 375, SLOT 4 | CHASSIS, INFO, switch, Log
Module BL has been enabled.
Use the rasadmin --show -module module_ID command to verify the status of the
messages that belong to a module.
Setting the severity level of a RASLog message
To change the default severity level of a RASLog message, perform the following steps.
1.
Log in to the switch as admin.
2.
Use the rasadmin --set -log message_ID -severity [DEFAULT | INFO | WARNING | ERROR |
CRITICAL] to change the severity level of a message. For example, execute the following
command to change the severity level of C2-1004 message to WARNING.
switch:admin> rasadmin --set -log C2-1004 -severity WARNING
3.
Use the rasadmin --show -severity message_ID command to verify the severity of the message.
switch:admin> rasadmin --show -severity C2-1004
Message
Severity
C2-1004 :
WARNING
Displaying system message logs and attributes
This section provides information on displaying the system message logs. These procedures are
valid for all the supported platforms.
Fabric OS Message Reference
53-1002749-01
Displaying system message logs and attributes
1
Displaying RASLog messages
To display the system message log on a switch with no page breaks, perform the following steps.
You can display the messages in reverse order using the reverse option. To display message logs in
all switches (logical switches), use the all option.
1.
Log in to the switch as admin.
2.
Enter the errDump command at the command line.
switch:admin> errdump
Version: v7.1.0
2000/12/17-05:54:30, [HAM-1004], 1, CHASSIS, INFO, switch, Processor rebooted
- Reset
2000/12/17-05:55:04, [ZONE-1034], 2, FID 128, INFO, switch, A new zone
database file is created.
2000/12/17-05:55:04, [FCR-1069], 3, FID 128, INFO, switch, The FC Routing
service is enabled.
2000/12/17-05:55:04, [FCR-1068], 4, FID 128, INFO, switch, The FC Routing
service is disabled.
2000/12/17-05:55:11, [EM-1034], 5, CHASSIS, ERROR, switch, PS 2 set to faulty,
rc=2000e.
[...]
Displaying RASLog messages one message at a time
To display the system message log one message at a time, perform the following steps.
1.
Log in to the switch as admin.
2.
Enter the errShow command at the command line.
switch:admin> errshow
Version: v7.1.0
2011/11/11-05:54:30, [HAM-1004], 1, CHASSIS, INFO, switch, Processor rebooted
- Reset
Type to continue, Q to stop:
2011/11/11-05:55:04, [ZONE-1034], 2, FID 128, INFO, switch, A new zone
database file is created.
Type to continue, Q to stop:
2011/11/11-05:55:04, [FCR-1069], 3, FID 128, INFO, switch, The FC Routing
service is enabled.
Type to continue, Q to stop:
[...]
Fabric OS Message Reference
19
53-1002749-01
Displaying system message logs and attributes
1
Displaying Audit messages
To display the Audit messages, perform the following steps. Beginning with Fabric OS v7.1.0
release, the RAS-3005 message is generated for each CLI command executed on switch and is
saved in the Audit message log.
1.
Log in to the switch as admin.
2.
Enter the auditDump -s command at the command line.
switch:admin> auditdump -s
0 AUDIT, 2011/01/14-06:06:49 (UTC), [RAS-2001], INFO, SYSTEM,
admin/admin/192.0.2.2/telnet/CLI, ad_0/switch/FID 128, , Audit message log is
enabled.
2 AUDIT, 2011/01/14-06:07:03 (UTC), [SEC-3020], INFO, SECURITY,
admin/admin/192.0.2.2/telnet/CLI ad_0/switch, , Event: login, Status: success,
Info: Successful login attempt via SERIAL.
3 AUDIT, 2011/01/14-06:07:33 (UTC), [SULB-1003], INFO, FIRMWARE,
admin/admin/192.0.2.2/telnet/CLI ad_0/switch, , Firmwarecommit has started.
4 AUDIT, 2011/12/11-10:08:58 (UTC), [SULB-1004], INFO, FIRMWARE,
admin/admin/192.0.2.2/telnet/CLI ad_0/switch, , Firmwarecommit has completed.
5 AUDIT, 2012/05/23-03:45:15 (UTC), [RAS-3005], INFO, CLI,
admin/admin/NONE/console/CLI, ad_0/switch/CHASSIS, , CLI: clihistory --all
6 AUDIT, 2012/05/23-04:12:04 (UTC), [RAS-3005], INFO, CLI,
admin/admin/NONE/console/CLI, ad_0/switch/CHASSIS, , CLI: auditdump -s
[...]
Displaying FFDC messages
To display the saved FFDC messages, perform the following steps.
1.
Log in to the switch as admin.
2.
Enter the errDump --attribute FFDC command at the command line.
switch:admin> errDump --attribute FFDC
Fabric OS: v7.1.0
2012/10/15-10:39:02, [LOG-1002], 4496, FFDC, WARNING, switch, A log
message was not recorded.
2012/10/15-10:39:18, [RAS-1001], 4496, FFDC, WARNING, switch, First
failure data capture (FFDC) event occurred.
[...]
Fabric OS Message Reference
53-1002749-01
Displaying system message logs and attributes
1
Displaying status of the system messages
To display the status of the system message, perform the following steps.
1.
Log in to the switch as admin.
2.
Use the following commands to display the status of all messages in the log, a single message,
or all messages that belong to a module:
•
Execute the rasadmin --show -all command to the status of all RASLog messages in the
system log.
switch:admin> rasadmin --show -all
Message
Status
Default Severity
Current Severity
FCIP-1000
ENABLED
CRITICAL
CRITICAL
FCIP-1001
ENABLED
INFO
ERROR
FCIP-1002
ENABLED
INFO
INFO
[...]
•
Execute the rasadmin --show -log message_ID command to display the status of a single
RASLog message.
switch:admin> rasadmin --show -log IPAD-1002
Message
Status
Default Severity
Current Severity
IPAD-1002
DISABLED
INFO
INFO
•
Execute the rasadmin --show -module module_ID command to display the status of all
messages that belong to the module.
switch:admin> rasadmin --show -module ECC
Message
Status
Default Severity
Current Severity
ECC-1000
ENABLED
ERROR
ERROR
ECC-1001
DISABLED
ERROR
WARNING
•
Execute the rasadmin --show -disabled command to display the list of all RASLog
messages that are disabled.
switch:admin> rasadmin --show -disabled
Message
Status
CDR-1001 : DISABLED
CDR-1003 : DISABLED
CDR-1004 : DISABLED
ECC-1001
: DISABLED
IPAD-1002
: DISABLED
Displaying the severity level of RASLog messages
To display the severity level of a RASLog message, perform the following steps.
1.
Log in to the switch as admin.
2.
Use the rasadmin --show -severity message_ID command to display the severity level of a
RASLog message. For example, execute the following command to display the status of the
SEC-1203 message.
switch:admin> rasadmin --show -severity SEC-1203
Message
Severity
SEC-1203 :
WARNING
Fabric OS Message Reference
21
53-1002749-01
Displaying system message logs and attributes
1
Displaying RASLog messages by severity level
To display the RASLog messages based on the severity level, perform the following steps.
1.
Log in to the switch as admin.
2.
Execute the errdump --severity [DEFAULT | INFO | WARNING | ERROR | CRITICAL] command.
For more information on message severity levels, refer to “Message severity levels” on page 3.
You can set the count of messages to display using the count option. The following example
filters messages by severity level of ERROR.
switch:admin> errdump --count 4 --severity ERROR
Fabric OS: v7.1.0
2012/10/24-11:23:24, [C3-1001], 12, CHASSIS, ERROR, switch, Port 4 failed due
to SFP validation failure. Check if the SFP is valid for the configuration.
2012/10/24-11:23:24, [C3-1001], 13, CHASSIS, ERROR, switch, Port 5 failed due
to SFP validation failure. Check if the SFP is valid for the configuration.
2012/10/24-11:23:25, [C3-1001], 14, CHASSIS, ERROR, switch, Port 18 failed due
to SFP validation failure. Check if the SFP is valid for the configuration.
2012/10/24-11:46:14, [C3-1001], 27, CHASSIS, ERROR, switch, Port 4 failed due
to SFP validation failure. Check if the SFP is valid for the configuration.
Displaying RASLog messages by message ID
To display the RASLog messages based on the message ID, perform the following steps.
1.
Log in to the switch as admin.
2.
Execute the errdump --message message_ID command. The following example displays all
instances of the message HAM-1004.
switch:admin> errdump --message HAM-1004
Fabric OS: v7.1.0
2012/11/27-16:18:38, [HAM-1004], 1, CHASSIS, INFO, switch, Processor rebooted
- Reset.
2012/11/27-17:26:44, [HAM-1004], 90, CHASSIS, INFO, switch, Processor rebooted
- FirmwareDownload.
2012/11/27-21:06:25, [HAM-1004], 201, CHASSIS, INFO, switch, Processor
rebooted - FirmwareDownload.
[...]
Displaying messages on a slot
To display the saved messages for a specific slot, perform the following steps.
1.
Log in to the switch as admin.
2.
Execute the errdump --slot slot_num command.
switch:admin> errdump --slot 4
Fabric OS: v7.1.0
2012/06/19-03:26:44, [HAM-1004], 31, SLOT 4 | CHASSIS, INFO, switch, Processor
rebooted - Reboot.
Fabric OS Message Reference
53-1002749-01
Clearing the system message logs
1
2012/06/19-03:26:44, [SULB-1003], 32, SLOT 4 | CHASSIS, INFO, switch,
Firmwarecommit has started.
2012/06/19-03:26:44, [IPAD-1001], 33, SLOT 4 | CHASSIS, INFO, switch, CP/1
IPv6 manual fe80::224:38ff:fe1b:4400 DHCP Off.
2012/06/19-03:29:15, [IPAD-1000], 48, SLOT 4 | CHASSIS, INFO, switch, CP/0
Ether/0 IPv6 autoconf fd00:60:69bc:816:205:1eff:fe84:3f49/64 tentative DHCP
Off.
[...]
NOTE
The slot option is not supported on the non-bladed systems.
Viewing RASLog messages from Web Tools
To view the system message log for a switch from Web Tools, perform the following steps.
1.
Launch Web Tools.
2.
Select the desired switch from the Fabric Tree. The Switch View displays.
3.
Click the Switch Events tab. You can view the switch events and messages in the Switch Events
Report displayed.
In dual-domain switches, an Event button exists for each logical switch. Only messages relating to
that switch (and chassis) will be displayed.
Clearing the system message logs
This section provides information on clearing the system message logs. These procedures are valid
for all the supported platforms.
Clearing the system message log
To clear the system message log for a particular switch instance, perform the following steps.
1.
Log in to the switch as admin.
2.
Execute the errClear command to clear all messages from memory.
NOTE
For products that have a single processor, all error log messages are cleared. For products that have
multiple processors, this command only clears the error logs of the processor from which it is
executed.
Fabric OS Message Reference
23
53-1002749-01
Reading the system messages
1
Clearing the Audit message log
To clear the Audit message log for a particular switch instance, perform the following steps.
1.
Log in to the switch as admin.
2.
Execute the auditDump -c command to clear all Audit messages from memory.
Reading the system messages
This section provides information about reading the RASLog and Audit messages.
Reading a RAS system message
This section provides information about reading system messages.
The following example shows the format of a RAS system error message.
, [], , , , ,
The following example shows a sample message from the error log.
2011/02/10-14:18:04, [SS-1000], 88, SLOT 6 | FFDC | CHASSIS, INFO, ESNSVT_DCX,
supportSave has uploaded support information to the host with IP address
192.0.2.2.
2011/02/10-14:13:34, [SS-1001], 87, SLOT 6/1 | FFDC | CHASSIS, WARNING,
ESNSVT_DCX, supportSave's upload operation to host IP address aborted.
2011/02/10-15:44:51, [SEC-1203], 89, SLOT 6 | FFDC | FID 128, INFO, ESNSVT_DCX,
Login information: Login successful via TELNET/SSH/RSH. IP Addr:192.0.2.2.
NOTE
Any reference to slot 0 in a system message is a reference to the blade within the switch platform,
for example, Brocade DCX contains FC8-48 blade, FC8-32 blade, FC8-16 blade, and so on.
The fields in the error message are described in Table 4.
TABLE 4
System message field description
Variable name
Description
Time Stamp
The system time (UTC) when the message was generated on the switch. The
RASLog subsystem supports an internationalized time stamp format based on
the “LOCAL” setting.
Event ID
The message module and number. These values uniquely identify each
message in the Fabric OS and reference the cause and actions recommended
in this manual. Note that not all message numbers are used; there can be
gaps in the numeric message sequence.
Fabric OS Message Reference
53-1002749-01
Reading the system messages
1
Reading an Audit message
Compared to RASLog error messages, messages flagged as AUDIT provide additional user and
system-related information of interest for post-event auditing and troubleshooting the problem.
The following example shows the format of the Audit event message.
AUDIT, , [], , ,
////, /, ,
The following is a sample Audit event message.
0 AUDIT, 2005/12/10-09:54:03, [SEC-1000], WARNING, SECURITY,
JohnSmith/root/192.0.2.2/Telnet/CLI, Domain A/JohnsSwitch, , Incorrect password
during login attempt.
Sequence Number
The error message position in the log. When a new message is added to the
log, this number is incremented by 1.
The message sequence number starts at 1 after a firmwareDownload and will
increase up to a value of 2,147,483,647 (0x7ffffff).
The sequence number continues to increase after the message log wraps
around, i.e. the oldest message in the log is deleted when a new message is
added. The sequence number can be reset to 1 using the errClear command.
The sequence number is persistent across power cycles and switch reboots.
Flags
For most messages, this field contains a space character (null value)
indicating that the message is neither an AUDIT or FFDC message. Messages
may contain the following values:
•
FFDC – Indicates that additional first failure data capture information has
also been generated for this event.
•
FID – The Fabric ID that can range from 0 to 128. FID 128 means the
message was generated by the default switch instance.
•
CHASSIS – The message that was generated by the chassis instance.
•
SLOT number – Indicates the message was generated from slot # blade
main CPU.
•
SLOT #/1 – Indicates the message was generated from slot # blade
Co-CPU.
Severity Level
The severity of the error, which can be one of the following:
•
1 – CRITICAL
•
2 – ERROR
•
3 – WARNING
•
4 – INFO
Switch name
The defined switch name or the chassis name of the switch depending on the
action; for example, high availability (HA) messages typically show the chassis
name, and login failures show the logical switch name.
This value is truncated if it exceeds 16 characters in length. Run either the
chassisName command to name the chassis or the switchName command to
rename the logical switch.
Event-specific information
A text string explaining the error encountered and providing parameters
supplied by the software at runtime.
TABLE 4
System message field description (Continued)
Variable name
Description
Fabric OS Message Reference
25
53-1002749-01
Reading the system messages
1
The fields in the error message are described in Table 5.
TABLE 5
Audit message field description
Variable name
Description
Sequence Number
The error message position in the log.
Audit flag
Identifies the message as an Audit message.
Time Stamp
The system time (UTC) when the message was generated on the switch. The
RASLog subsystem will support an internationalized time stamp format
based on the “LOCAL” setting.
Event ID
The message module and number. These values uniquely identify each
message in the Fabric OS and reference the cause and actions
recommended in this manual. Note that not all message numbers are used;
there can be gaps in the numeric message sequence.
Severity
The severity of the error, which can be one of the following:
•
1 – CRITICAL
•
2 – ERROR
•
3 – WARNING
•
4 – INFO
Event Class
The event class, which can be one of the following:
•
CFG
•
CLI
•
FABRIC
•
FIRMWARE
•
FW
•
LS
•
MAPS (internal use only)
•
RAS
•
SECURITY
•
ZONE
User ID
The user ID.
Role
The role of the user ID.
IP address
The IP address.
Interface
The interface being used.
Application Name
The application name being used on the interface.
Admin Domain
The Admin Domain, if there is one.
Switch name
The defined switch name or the chassis name of the switch depending on
the action; for example, HA messages typically show the chassis name and
login failures show the logical switch name.
This value is truncated if it is over 16 characters in length.
Execute the chassisName command to name the chassis or the switchName
command to rename the logical switch.
Reserved field for future
expansion
This field is reserved for future use and contains a space character (null
value).
Event-specific information
A text string explaining the error encountered and providing parameters
supplied by the software at runtime.
Fabric OS Message Reference
53-1002749-01
Responding to a system message
1
Responding to a system message
This section provides procedures on gathering information on system messages.
Looking up a system message
Messages in this manual are arranged alphabetically by Module ID, and then numerically within a
given module. To look up a message, copy down the module (see Table 6 on page 28) and the error
code and compare this with the Table of Contents or look up lists to determine the location of the
information for that message.
The following information is provided for each message:
•
Module and code name for the error
•
Message text
•
Message type
•
Class (for Audit messages only)
•
Message severity
•
Probable cause
•
Recommended action
Gathering information about the problem
Questions to ask yourself when troubleshooting a system message are as follows:
•
What is the current Fabric OS level?
•
What is the switch hardware version?
•
Is the switch operational?
•
Assess impact and urgency:
-
Is the switch down?
-
Is it a standalone switch?
-
How large is the fabric?
-
Is the fabric redundant?
•
Execute the errDump command on each logical switch.
•
Execute the supportFtp command (as needed) to set up automatic FTP transfers, and then run
the supportSave command.
•
Document the sequence of events by answering the following questions:
-
What happened just prior to the problem?
-
Is the problem repeatable?
-
If so, what are the steps to produce the problem?
-
What configuration was in place when the problem occurred?
•
Did a failover occur?
•
Was security enabled?
•
Was POST enabled?
Fabric OS Message Reference
27
53-1002749-01
Responding to a system message
1
•
Are serial port (console) logs available?
•
Which CP was master?
•
What and when were the last actions or changes made to the system?
Common steps to be followed when troubleshooting a system message are as follows:
•
Execute the errDump command on each logical switch.
•
Execute the supportFtp command (as needed) to set up automatic FTP transfers, and then
execute the supportSave command.
Support
Fabric OS creates a number of files that can help support personnel troubleshoot and diagnose a
problem. This section describes those files and how to access or save the information for support
personnel.
Panic dump and core dump files
The Fabric OS creates panic dump files and core files when there are problems in the Fabric OS
kernel. You can view panic dump files using the pdShow command. These files can build up in the
kernel partition (typically because of failovers) and might need to be periodically deleted or
downloaded using the supportSave command.
The software watchdog process (SWD) is responsible for monitoring daemons critical to the
function of a healthy switch. The SWD holds a list of critical daemons that ping the SWD periodically
at a predetermined interval defined for each daemon. The ping interval is set at 133 seconds, with
the exception of the Fabric Watch daemon and the IP storage demon, which ping the SWD every
333 seconds. (For a complete listing of daemons, refer to the KSWD entry in Table 6.)
If a daemon fails to ping the SWD within the defined interval, or if the daemon terminates
unexpectedly, then the SWD dumps information to the panic dump files, which helps to diagnose
the root cause of the unexpected failure.
Execute the pdShow command to view these files or the supportSave command to send them to a
host workstation using FTP. The panic dump files and core files are intended for support personnel
use only.
Trace dumps
The Fabric OS produces trace dumps when problems are encountered within Fabric OS modules.
The Fabric OS trace dump files are intended for support personnel use only. You can use the
supportSave or supportFTP commands to collect trace dump files to a specified remote location to
provide to support when requested.
supportSave command
The supportSave command can be used to send the output of the system messages (RASLog), the
trace files, and the output of the supportShow command to an off-switch storage location through
FTP. Prior to running the supportSave command, you can optionally set up the FTP parameters
using the supportFtp command. The supportShow command runs a large number of dump and
show commands to provide a global output of the status of the switch. Refer to the Fabric OS
Command Reference for more information on these commands.
Fabric OS Message Reference
53-1002749-01
System module descriptions
1
System module descriptions
Table 6 provides a summary of the system modules for which messages are documented in this
guide; the system modules are listed alphabetically by name. A module is a subsystem in the Fabric
OS. Each module generates a set of numbered messages.
TABLE 6
System module descriptions
System
module
Description
AG
Access Gateway (AG) allows multiple hosts (or HBAs) to access the fabric using fewer physical ports.
Access Gateway mode transforms the Brocade switches as well as embedded switches into a device
management tool that is compatible with different types of fabrics, including Brocade-, Cisco-, and
McDATA-based fabrics.
AN
Error or warning messages from the Bottleneck Detection module, including notification of detected
bottlenecks.
ANV
ANV error messages indicate problems with the driver that deal with the ENET application-specific
integrated circuits (ASICs) on the Fabric OS. They can be software- or hardware-related errors.
AUTH
Authentication error messages indicate problems with the authentication module of the Fabric OS.
BKSW
BKSW messages are generated by the Fabric OS blade kernel software watchdog module.
BL
BL error messages are a result of faulty hardware, transient out-of-memory conditions, ASIC errors,
or inconsistencies in the software state between a blade and the environment monitor (EM) module.
BLS
Fibre Channel over IP port configuration messages over the Brocade 7800 and FX8-24 blade.
BM
Blade management error messages are a result of autoleveling firmware upgrades performed by the
control processor (CP).
C2
C2 error messages indicate problems with the 8 Gbps-capable FC module of the Fabric OS.
C3
C3 error messages indicate problems with the 16 Gbps-capable FC module of the Fabric OS.
CAL
Common Access Layer (CAL) provides XML interface for configuring switch parameters in an object
model.
CCFG
CCFG error messages indicate problems with the Converged Enhanced Ethernet (CEE) configuration
module of the Fabric OS.
CDR
Driver error messages.
CHS
Error messages reporting the problems in the management of the blades in the different slots of the
chassis.
CNM
Cluster Node Manager (CNM) is a software daemon module of the Fabric OS. The messages from
CNM are problems encountered by CNM, warnings, or information to the user of events.
CONF
Status messages for configUpload and configDownload operations.
CTAP
A user-space daemon that forwards non-performance-critical messages from the TAPE driver to the
Crypto Virtual LUN Controller (CVLC) and Security Processor (SP), and vice versa. This module also
maintains a cache of recently acquired keys, reducing requests to the key vault itself.
CVLC
Crypto Virtual LUN Controller (CVLC) is a software module running on blade FOS (BFOS). The
messages of CVLC are problems encountered by CVLC, warnings to alert the user, or information to
the user.
CVLM
Crypto Virtual LUN Manager (CVLM) is a software module of the Fabric OS. The messages of CVLM
are problems encountered by CVLM, warnings to alert the user, or information to the user.
DOT1
DOT1 error messages indicate problems with the 802.1x authentication module of the Fabric OS.
Fabric OS Message Reference
29
53-1002749-01
System module descriptions
1
ECC
Error Checking and Correction (ECC) error messages indicate single-bit and multiple-bit errors in the
Dynamic Random Access Memory (DRAM) devices. ECC is a technology that helps to correct memory
errors.
EM
The environmental monitor (EM) manages and monitors the various field-replaceable units (FRUs),
including the port cards, control processor (CP) blades, blower assemblies, power supplies, and
World Wide Name (WWN) cards. EM controls the state of the FRUs during system startup, hot-plug
sequences, and fault recovery.
EM provides access to and monitors the sensor and status data from the FRUs and maintains the
integrity of the system using the environmental and power policies. EM reflects system status by CLI
commands, system light emitting diodes (LEDs), and status and alarm messages. EM also manages
some component-related data.
ESS
Exchange Switch Support (ESS) error messages indicate problems with the ESS module of the Fabric
OS. ESS is an SW_ILS mechanism utilized by switches to exchange vendor and support information.
ESW
ESW error messages indicate problems with the Ethernet switch module of Fabric OS.
EVMD
EVMD is the event management module.
FABR
FABRIC refers to a network of Fibre Channel switches. The FABR error messages come from the
fabric daemon. The fabric daemon follows the FC-SW-3 standard for the fabric initialization process,
such as determining the E_Ports, assigning unique domain IDs to switches, creating a spanning tree,
throttling the trunking process, and distributing the domain and alias lists to all switches in the
fabric.
FABS
Fabric OS system driver module.
FBC
Firmware blade compatibility errors with the control processor (CP).
FCMC
Fibre Channel miscellaneous messages relate to problems with the physical layer used to send Fibre
Channel traffic to and from the switch.
FCOE
FCoE error messages indicate problems with the FCoE module of the Fabric OS.
FCPD
The Fibre Channel Protocol daemon is responsible for probing the devices attached to the loop port.
Probing is a process the switch uses to find the devices attached to the loop ports and to update the
Name Server with the information.
FCPH
The Fibre Channel Physical Layer is used to send Fibre Channel traffic to and from the switch.
FCR
Fibre Channel router-related traffic and activity on the fabric or back-end fabric.
FICN
The FICN messages are generated during FICON emulation processing on an FCIP Tunnel.
FICU
The FICON-CUP daemon handles communication with fibre connectivity (FICON) on IBM FICON
storage devices. Errors to this module are usually initiation errors or indications that FICON-CUP
prerequisites have not been met, such as a license key, core process ID (PID), and secure mode on
the fabric.
FKLB
Fabric OS I/O kernel library module.
FLOD
FLOD is a part of the Fabric Shortest Path First (FSPF) protocol that handles synchronization of the
link state database (LSDB) and propagation of the link state records (LSRs).
FSPF
Fabric Shortest Path First (FSPF) is a link state routing protocol that is used to determine how frames
should be routed. These messages are about protocol errors.
TABLE 6
System module descriptions (Continued)
System
module
Description
Fabric OS Message Reference
53-1002749-01
System module descriptions
1
FSS
The Fabric OS state synchronization framework provides facilities by which the active control
processor (CP) can synchronize with the standby CP, enabling the standby CP to take control of the
switch nondisruptively during failures and software upgrades. These facilities include version
negotiation, state information transfer, and internal synchronization functions, enabling the
transition from standby to active operation.
FSS is defined both as a component and a service. A component is a module in the Fabric OS,
implementing a related set of functionality. A service is a collection of components grouped together
to achieve a modular software architecture.
FSSM
The Fabric OS state synchronization management module is defined both as a component and a
service. A component is a module in Fabric OS, implementing a related set of functionality. A service
is a collection of components grouped together to achieve a modular software architecture.
FW
FW is the Fabric Watch module. This module monitors thresholds for many switch subsystems; for
example, temperature, voltage, fan speed, and switch status. Any changes that cross a specified
threshold are reported to the system message log.
HAM
HAM is a user-space daemon responsible for high availability management.
HAMK
This is the kernel module for the high availability management (HAM) daemon.
HIL
Hardware independent layer.
HLO
HLO is a part of the Fabric Shortest Path First (FSPF) protocol that handles the HELLO protocol
between adjacent switches. The HELLO protocol is used to establish connectivity with a neighbor
switch, to establish the identity of the neighbor switch, and to exchange FSPF parameters and
capabilities.
HMON
Health monitor.
HSL
HSL error messages indicate problems with the Hardware Subsystem Layer of the Fabric OS.
HTTP
HTTP error messages.
IBD
IBD generates messages related to port restart failure.
IPAD
System messages generated by the IP admin demon.
IPS
Fibre Channel over IP license, tunneling, and port-related messages.
ISNS
ISNS server and client status messages.
KAC
KAC error messages indicate problems associated with Fabric OS and the external key vaults.
KSWD
The kernel software watchdog (KSWD) watches daemons for unexpected terminations and “hang”
conditions and informs the HAM module to take corrective actions such as failover or reboot.
The following daemons are monitored by KSWD:
•
Access Gateway daemon (agd)
•
Alias Server daemon (asd)
•
ARR daemon (arrd)
•
Authentication daemon (authd)
•
Blade Manager daemon (bmd)
•
Cluster Node Manager daemon (cnmd)
•
Common Access Layer daemon (cald)
•
DAUTH daemon (dauthd)
•
Diagnostics daemon (diagd)
•
Environment Monitor daemon (emd)
•
Event Manager daemon (evmd)
•
Exchange Switch Support daemon (essd)
•
FA-API rpc daemon (rpcd)
TABLE 6
System module descriptions (Continued)
System
module
Description
Fabric OS Message Reference
31
53-1002749-01
System module descriptions
1
KSWD
(continued)
•
Fabric daemon (fabricd)
•
Fabric Device Management Interface daemon (fdmid)
•
Fabric Watch daemon (fwd)
•
FCoE daemon (fcoed)
•
Fibre Channel Protocol daemon (fcpd)
•
FICON CUP daemon (ficud)
•
FSPF daemon (fspfd)
•
IGMP daemon (igmpd)
•
IMI daemon (imid)
•
Inter-fabric Routing daemon (iswitchd)
•
IP Storage daemon (ipsd)
•
ISNS client daemon on CP (isnscd)
•
KAC daemon (kacd)
•
Layer 2 System daemon (l2sysd)
•
LFM daemon (lfmd)
•
Link Aggregation Control Protocol daemon (lacpd)
•
Management Server daemon (msd)
•
MM daemon (mmd)
•
Multicast Sub-System daemon (mcast_ssd)
•
Multiple Spanning Tree Protocol daemon (mstpd)
•
Name Server daemon (nsd)
•
NSM daemon (nsmd)
•
ONM daemon (onmd)
•
Parity data manager daemon (pdmd)
•
Proxy daemon (proxyd)
•
PS daemon (psd)
•
RASLOG daemon (raslogd)
•
RCS daemon (rcsd)
•
RM daemon (rmd)
•
RMON daemon (rmond)
•
Security daemon (secd)
•
Sigma daemon (sigmad)
•
SNMP daemon (snmpd)
•
SP management daemon (spmd)
•
SVP daemon (svpd)
•
System services module daemon (ssmd)
•
Time Service daemon (tsd)
•
TRACE daemon (traced)
•
Traffic daemon (trafd)
•
VS daemon (vsd)
•
Web linker daemon (weblinkerd)
•
Web Tools daemon (webd)
•
ZONE daemon (zoned)
KTRC
Kernel RAS trace module.
L2SS
L2SYS error messages indicate problems with the Layer 2 System manager that controls the Layer 2
forwarding engine and controls the learning/aging/forwarding functionality.
LACP
LACP error messages indicate problems with the Link Aggregation Control Protocol module of the
Fabric OS.
LANCE
LANCE error messages indicate problems with the LANCE module of the Fabric OS.
TABLE 6
System module descriptions (Continued)
System
module
Description
Fabric OS Message Reference
53-1002749-01
System module descriptions
1
LFM
LFM error messages indicate problems with the logical fabric manager module that is responsible
for making a logical switch use XISLs. This involves creating and managing LISLs in a logical fabric.
LOG
RASLog subsystem.
LSDB
The link state database is a part of the FSPF protocol that maintains records on the status of port
links. This database is used to route frames.
MCAST_SS
The Multicast Sub-System messages indicate any problems associated with the Layer 2 and Layer 3
Multicast platform support, including allocation of global platform resources such as MGIDs,
hardware acceleration resources for Multicast, and route programming into the hardware (Layer 2
EXM for IGMP Snooping).
MFIC
MS-FICON messages relate to Fibre Connection (FICON) installations. Fibre Connection control unit
port (FICON-CUP) messages are displayed under the FICU module.
MM
MM message indicate problems with the management modules.
MPTH
Multicast path uses the shortest path first (SPF) algorithm to dynamically compute a broadcast tree.
MQ
Message queues are used for interprocess communication. Message queues allow many messages,
each of variable length, to be queued. Any process or interrupt service routine (ISR) can write
messages to a message queue. Any process can read messages from a message queue.
MS
The Management Service enables the user to obtain information about the Fibre Channel fabric
topology and attributes by providing a single management access point. MS provides for both
monitoring and control of the following areas:
•
Fabric Configuration Server: Provides for the configuration management of the fabric.
•
Unzoned Name Server: Provides access to Name Server information that is not subject to zone
constraints.
•
Fabric Zone Server: Provides access to and control of zone information.
MSTP
MSTP error messages indicate problems with Multiple Spanning Tree Protocol modules of the Fabric
OS.
NBFS
NBFSM is a part of the Fabric Shortest Path First (FSPF) protocol that handles a neighboring or
adjacent switch’s finite state machine (FSM).
Input to the FSM changes the local switch from one state to another, based on specific events. For
example, when two switches are connected to each other using an interswitch link (ISL) cable, they
are in the Init state. After both switches receive HELLO messages, they move to the Database
Exchange state, and so on.
NBFSM states are Down (0), Init (1), Database Exchange (2), Database Acknowledge Wait (3),
Database Wait (4), and Full (5).
NS
Indicates problems with the simple Name Server module.
NSM
NSM error messages indicate problems with the Interface Management and VLAN Management
module of the Fabric OS.
ONMD
ONMD error messages indicate problems with the Operation, Administration and Maintenance
module of the Fabric OS.
PDM
Parity data manager (PDM) is a user-space daemon responsible for the replication of persistent
configuration files from the primary partition to the secondary partition and from the active CP blade
to the standby CP blade.
PDTR
PDTR messages indicate panic dump trace files have been created.
PLAT
PLAT messages indicate hardware problems.
PMGR
A group of messages relating to logical switch creation, deletion, and configuration.
TABLE 6
System module descriptions (Continued)
System
module
Description
Fabric OS Message Reference
33
53-1002749-01
System module descriptions
1
PORT
PORT error messages refer to the front-end user ports on the switch. Front-end user ports are
directly accessible by users to connect end devices or connect to other switches.
PS
The performance server daemon measures the amount of traffic between endpoints or traffic with
particular frame formats, such as SCSI frames, IP frames, and customer-defined frames.
PSWP
The portswap feature and associated commands generate these error messages.
RAS
Informational messages when first failure data capture (FFDC) events are logged to the FFDC log
and size or roll-over warning.
RCS
The reliable commit service daemon generates log entries when it receives a request from the
zoning, security, or management server for passing data messages to switches in the fabric. RCS
then requests reliable transport write and read (RTWR) to deliver the message. RCS also acts as a
gatekeeper, limiting the number of outstanding requests for the Zoning, Security, or Management
Server modules.
RKD
These messages are either error or informational messages pertaining to the re-key daemon of the
Fabric OS.
RMON
RMON messages are error or informational messages pertaining to the RMOND daemon.
RPCD
The remote procedure call daemon (RPCD) is used by Fabric Access for API-related tasks.
RTE
RTE is responsible for determining the correct paths for each ingress frame and populating the
routing tables in the ASICs with this information. The ASIC then uses the information available in the
routing tables to determine the path a particular ingress frame needs to take before it exits the
switch.
RTWR
The reliable transport write and read daemon helps deliver data messages either to specific
switches in the fabric or to all of the switches in the fabric. For example, if some of the switches are
not reachable or are offline, RTWR returns an “unreachable” message to the caller, allowing the
caller to take the appropriate action. If a switch is not responding, RTWR retries 100 times.
SCN
The internal state change notification daemon is used for state change notifications from the kernel
to the daemons within Fabric OS.
SEC
The security daemon generates security errors, warnings, or information during security-related data
management or fabric merge operations. Administrators should watch for these messages to
distinguish between internal switch and fabric operation errors and external attacks.
SFLO
sFlow is a standard-based sampling technology embedded within switches and routers, which is
used to monitor high-speed network traffic for Data Center Ethernet (DCE) and Converged Enhanced
Ethernet (CEE) platforms.
sFlow uses two types of sampling:
•
Statistical packet-based sampling of switched or routed packet flows.
•
Time-based sampling of interface counters.
SFLO messages indicate errors or information related to the sflowd daemon.
SNMP
Simple Network Management Protocol (SNMP) is a universally supported low-level protocol that
allows simple get, get next, and set requests to go to the switch (acting as an SNMP agent). It also
allows the switch to send traps to the defined and configured management station. Brocade
switches support six management entities that can be configured to receive these traps.
SPC
SPC messages indicate problems and informational updates associated with the security processor.
These messages could be triggered by the following three modules: Security processor controller, SP
system controller, and SP Keyapp.
SPM
Error messages indicating problems either with key or SP management.
SS
The supportSave command generates these error messages if problems are encountered.
TABLE 6
System module descriptions (Continued)
System
module
Description
Fabric OS Message Reference
53-1002749-01
System module descriptions
1
SSMD
SSMD error messages indicate problems with the System Services Module of the Fabric OS.
SULB
The software upgrade library provides the firmwareDownload command capability, which enables
firmware upgrades to both CP blades with a single command, as well as nondisruptive code load to
all Fabric OS switches. These messages might display if there are any problems during the
firmwareDownload procedure. Most messages are informational only and are generated even during
successful firmware download. For additional information, refer to the Fabric OS Administrator’s
Guide.
SWCH
These messages are generated by the switch driver module that manages a Fibre Channel switch
instance.
SYSC
System controller is a daemon that starts up and shuts down all Fabric OS modules in the proper
sequence.
SYSM
General system messages.
TAPE
A kernel-space driver that handles all I/O operations aimed at Tape containers.
TRCE
RAS TRACE error messages.
TRCK
The track change feature tracks the following events:
•
Turning on or off the track change feature
•
CONFIG_CHANGE
•
LOGIN
•
LOGOUT
•
FAILED_LOGIN
If any of these events occur, a message is sent to the system message log. Additionally, if the SNMP
trap option is enabled, an SNMP trap is also sent.
For information on configuring the track change feature, refer to the Fabric OS Command Reference
or the Fabric OS Administrator’s Guide.
TS
Time Service provides fabric time-synchronization by synchronizing all clocks in the fabric to the
clock time on the principal switch.
UCST
UCST is a part of the Fabric Shortest Path First (FSPF) protocol that manages the Unicast routing
table.
UPTH
UPATH is a part of the FSPF protocol that uses the SPF algorithm to dynamically compute a Unicast
tree.
VDR
VDR messages indicate Field-Programmable Gate Array (FPGA) parity errors.
VS
The VS module messages indicate any problems or information associated with the Dynamic Fabric
Provisioning feature, including commands associated with the fapwwn command and
configurations.
WEBD
Indicates problems with the Web Tools module.
XTUN
XTUN messages are generated by the FCIP Tunnel implementation. These messages indicate status
of FCIP tunnels, FCIP emulation events for FCP traffic, or FCIP debug information (FTRACE buffer
status changes).
ZEUS
Zeus error messages indicate problems with the Zeus driver module.
ZONE
The zone module messages indicate any problems associated with the zoning features, including
commands associated with aliases, zones, and configurations.
TABLE 6
System module descriptions (Continued)
System
module
Description
Fabric OS Message Reference
35
53-1002749-01
Chapter
2
Log Messages
AG Messages
AG-1001
AG-1002
AG-1003
AG-1004
AG-1005
AG-1006
AG-1007
AG-1008
AG-1009
AG-1010
AG-1011
AG-1012
AG-1013
AG-1014
AG-1015
AG-1016
AG-1017
AG-1018
AG-1019
AG-1020
AG-1021
AG-1022
AG-1023
AG-1024
AG-1025
AG-1026
AG-1027
AG-1028
Fabric OS Message Reference
53-1002749-01
AN Messages
2
AG-1029
AG-1030
AG-1031
AG-1032
AG-1033
AG-1034
AG-1035
AG-1036
AG-1037
AG-1038
AG-1039
AG-1040
AG-1041
AG-1042
AG-1043
AG-1044
AN Messages
AN-1001
AN-1002
AN-1003
AN-1004
AN-1005
AN-1010
AN-1011
AN-1012
AN-1013
ANV Messages
ANV-1001
ANV-1002
ANV-1003
ANV-1004
ANV-1005
Fabric OS Message Reference
37
53-1002749-01
AUTH Messages
2
ANV-1006
ANV-1007
ANV-1008
ANV-1015
ANV-1016
ANV-1028
AUTH Messages
AUTH-1001
AUTH-1002
AUTH-1003
AUTH-1004
AUTH-1005
AUTH-1006
AUTH-1007
AUTH-1008
AUTH-1010
AUTH-1011
AUTH-1012
AUTH-1013
AUTH-1014
AUTH-1016
AUTH-1017
AUTH-1018
AUTH-1020
AUTH-1022
AUTH-1023
AUTH-1025
AUTH-1026
AUTH-1027
AUTH-1028
AUTH-1029
AUTH-1030
AUTH-1031
AUTH-1032
Fabric OS Message Reference
53-1002749-01
BKSW Messages
2
AUTH-1033
AUTH-1034
AUTH-1035
AUTH-1036
AUTH-1037
AUTH-1038
AUTH-1039
AUTH-1040
AUTH-1041
AUTH-1042
AUTH-1043
AUTH-1044
AUTH-1045
AUTH-1046
AUTH-1047
BKSW Messages
BKSW-1003
BL Messages
BL-1000
BL-1001
BL-1002
BL-1003
BL-1004
BL-1006
BL-1007
BL-1008
BL-1009
BL-1010
BL-1011
BL-1012
BL-1013
BL-1014
Fabric OS Message Reference
39
53-1002749-01
BL Messages
2
BL-1015
BL-1016
BL-1017
BL-1018
BL-1019
BL-1020
BL-1021
BL-1022
BL-1023
BL-1024
BL-1025
BL-1026
BL-1027
BL-1028
BL-1029
BL-1030
BL-1031
BL-1032
BL-1033
BL-1034
BL-1035
BL-1036
BL-1037
BL-1038
BL-1039
BL-1041
BL-1045
BL-1046
BL-1047
BL-1048
BL-1049
BL-1050
BL-1051
BL-1052
Fabric OS Message Reference
53-1002749-01
BLS Messages
2
BLS Messages
BLS-1000
BLS-1001
BLS-1002
BLS-1003
BLS-1004
BLS-1005
BM Messages
BM-1001
BM-1002
BM-1003
BM-1004
BM-1005
BM-1006
BM-1007
BM-1008
BM-1009
BM-1010
BM-1053
BM-1054
BM-1055
BM-1056
BM-1058
C2 Messages
C2-1001
C2-1002
C2-1004
C2-1006
C2-1007
C2-1008
C2-1009
C2-1010
Fabric OS Message Reference
41
53-1002749-01
C3 Messages
2
C2-1012
C2-1013
C2-1014
C2-1015
C2-1016
C2-1017
C2-1018
C2-1019
C2-1025
C2-1026
C2-1027
C2-1028
C3 Messages
C3-1001
C3-1002
C3-1004
C3-1006
C3-1007
C3-1008
C3-1009
C3-1010
C3-1011
C3-1012
C3-1013
C3-1014
C3-1015
C3-1016
C3-1017
C3-1018
C3-1019
C3-1020
C3-1021
C3-1023
C3-1025
Fabric OS Message Reference
53-1002749-01
CAL Messages
2
C3-1026
C3-1027
C3-1028
CAL Messages
CAL-1001
CCFG Messages
CCFG-1001
CCFG-1002
CCFG-1003
CCFG-1004
CCFG-1005
CCFG-1006
CCFG-1007
CCFG-1008
CCFG-1009
CCFG-1010
CCFG-1011
CCFG-1012
CDR Messages
CDR-1001
CDR-1002
CDR-1003
CDR-1004
CDR-1005
CDR-1006
CDR-1007
CDR-1008
CDR-1009
CDR-1010
CDR-1011
CDR-1012
Fabric OS Message Reference
43
53-1002749-01
CHS Messages
2
CDR-1014
CDR-1015
CDR-1016
CDR-1017
CDR-1018
CDR-1019
CDR-1022
CDR-1028
CHS Messages
CHS-1002
CHS-1003
CHS-1004
CHS-1005
CNM Messages
CNM-1001
CNM-1002
CNM-1003
CNM-1004
CNM-1005
CNM-1006
CNM-1007
CNM-1008
CNM-1009
CNM-1010
CNM-1011
CNM-1012
CNM-1013
CNM-1014
CNM-1015
CNM-1016
CNM-1017
CNM-1018
Fabric OS Message Reference
53-1002749-01
CNM Messages
2
CNM-1019
CNM-1020
CNM-1021
CNM-1022
CNM-1023
CNM-1024
CNM-1025
CNM-1026
CNM-1027
CNM-1028
CNM-1029
CNM-1030
CNM-1031
CNM-1032
CNM-1033
CNM-1034
CNM-1035
CNM-1036
CNM-1037
CNM-1038
CNM-1039
CNM-1040
CNM-1041
CNM-1042
CNM-1043
CNM-1044
CNM-1045
CNM-1046
CNM-1047
CNM-1048
CNM-1049
CNM-1050
CNM-1051
CNM-1052
CNM-1053
Fabric OS Message Reference
45
53-1002749-01
CONF Messages
2
CNM-1054
CNM-1055
CNM-1056
CNM-1057
CNM-1058
CNM-1059
CNM-1060
CNM-1061
CNM-1062
CNM-3001
CNM-3002
CNM-3003
CNM-3004
CNM-3005
CNM-3006
CNM-3007
CNM-3008
CNM-3009
CNM-3010
CNM-3011
CNM-3012
CONF Messages
CONF-1000
CONF-1001
CONF-1021
CONF-1023
CONF-1024
CONF-1030
CONF-1031
CONF-1032
CONF-1040
CONF-1041
CONF-1042
CONF-1043
Fabric OS Message Reference
53-1002749-01
CTAP Messages
2
CONF-1044
CTAP Messages
CTAP-1001
CVLC Messages
CVLC-1001
CVLC-1002
CVLC-1003
CVLC-1004
CVLC-1005
CVLC-1006
CVLC-1007
CVLC-1008
CVLC-1009
CVLC-1010
CVLC-1011
CVLC-1012
CVLC-1013
CVLC-1014
CVLC-1015
CVLC-1016
CVLC-1017
CVLC-1018
CVLC-1019
CVLC-1020
CVLC-1021
CVLC-1022
CVLC-1023
CVLC-1024
CVLC-1025
CVLC-1026
CVLC-1027
CVLC-1028
Fabric OS Message Reference
47
53-1002749-01
CVLM Messages
2
CVLC-1029
CVLC-1030
CVLC-1031
CVLC-1032
CVLC-1033
CVLC-1034
CVLC-1035
CVLC-1039
CVLC-1041
CVLM Messages
CVLM-1001
CVLM-1002
CVLM-1003
CVLM-1004
CVLM-1005
CVLM-1006
CVLM-1007
CVLM-1008
CVLM-1009
CVLM-1010
CVLM-1011
CVLM-1012
CVLM-1013
CVLM-1014
CVLM-1015
CVLM-1016
CVLM-3001
CVLM-3002
CVLM-3003
CVLM-3004
CVLM-3005
CVLM-3006
CVLM-3007
CVLM-3008
Fabric OS Message Reference
53-1002749-01
DOT1 Messages
2
CVLM-3009
CVLM-3010
CVLM-3011
CVLM-3012
CVLM-3013
CVLM-3014
CVLM-3015
CVLM-3016
CVLM-3017
CVLM-3018
CVLM-3019
CVLM-3020
CVLM-3021
CVLM-3022
CVLM-3023
CVLM-3024
CVLM-3025
CVLM-3026
CVLM-3027
CVLM-3028
DOT1 Messages
DOT1-1001
DOT1-1002
DOT1-1003
DOT1-1004
DOT1-1005
DOT1-1006
DOT1-1007
DOT1-1008
DOT1-1009
DOT1-1010
Fabric OS Message Reference
49
53-1002749-01
ECC Messages
2
ECC Messages
ECC-1000
ECC-1001
EM Messages
EM-1001
EM-1002
EM-1003
EM-1004
EM-1005
EM-1006
EM-1008
EM-1009
EM-1010
EM-1011
EM-1012
EM-1013
EM-1014
EM-1015
EM-1016
EM-1017
EM-1018
EM-1019
EM-1020
EM-1028
EM-1029
EM-1031
EM-1033
EM-1034
EM-1035
EM-1036
EM-1037
EM-1042
EM-1043
Fabric OS Message Reference
53-1002749-01
ESS Messages
2
EM-1044
EM-1045
EM-1046
EM-1047
EM-1048
EM-1049
EM-1050
EM-1051
EM-1057
EM-1058
EM-1059
EM-1060
EM-1061
EM-1062
EM-1063
EM-1064
EM-1065
EM-1066
EM-1067
EM-1068
EM-1069
EM-1070
EM-1071
EM-1072
EM-2003
ESS Messages
ESS-1001
ESS-1002
ESS-1003
ESS-1004
ESS-1005
ESS-1008
ESS-1009
ESS-1010
Fabric OS Message Reference
51
53-1002749-01
ESW Messages
2
ESW Messages
ESW-1001
ESW-1002
ESW-1003
ESW-1004
ESW-1005
ESW-1006
ESW-1007
ESW-1008
EVMD Messages
EVMD-1001
FABR Messages
FABR-1001
FABR-1002
FABR-1003
FABR-1004
FABR-1005
FABR-1006
FABR-1007
FABR-1008
FABR-1009
FABR-1010
FABR-1011
FABR-1012
FABR-1013
FABR-1014
FABR-1015
FABR-1016
FABR-1017
FABR-1018
FABR-1019
FABR-1020
Fabric OS Message Reference
53-1002749-01
FABS Messages
2
FABR-1021
FABR-1022
FABR-1023
FABR-1024
FABR-1029
FABR-1030
FABR-1031
FABR-1032
FABR-1034
FABR-1035
FABR-1036
FABR-1037
FABR-1038
FABR-1039
FABR-1040
FABR-1041
FABR-1043
FABR-1044
FABR-1045
FABR-1046
FABR-1047
FABR-1048
FABR-1049
FABR-1050
FABR-1051
FABR-1052
FABR-1053
FABR-1054
FABR-1055
FABS Messages
FABS-1001
FABS-1002
FABS-1004
FABS-1005
Fabric OS Message Reference
53
53-1002749-01
FBC Messages
2
FABS-1006
FABS-1007
FABS-1008
FABS-1009
FABS-1010
FABS-1011
FABS-1013
FABS-1014
FABS-1015
FBC Messages
FBC-1001
FCMC Messages
FCMC-1001
FCOE Messages
FCOE-1001
FCOE-1002
FCOE-1003
FCOE-1004
FCOE-1005
FCOE-1006
FCOE-1007
FCOE-1009
FCOE-1010
FCOE-1012
FCOE-1014
FCOE-1015
FCOE-1016
FCOE-1017
FCOE-1019
FCOE-1021
FCOE-1022
Fabric OS Message Reference
53-1002749-01
FCPD Messages
2
FCOE-1023
FCOE-1024
FCOE-1025
FCOE-1026
FCOE-1027
FCOE-1028
FCOE-1029
FCOE-1030
FCOE-1031
FCOE-1032
FCOE-1033
FCOE-1034
FCOE-1037
FCOE-1038
FCOE-1039
FCOE-1040
FCOE-1041
FCOE-1042
FCOE-1043
FCOE-1044
FCOE-1045
FCOE-1046
FCOE-1047
FCOE-1048
FCPD Messages
FCPD-1001
FCPD-1002
FCPD-1003
FCPH Messages
FCPH-1001
FCPH-1002
FCPH-1003
Fabric OS Message Reference
55
53-1002749-01
FCR Messages
2
FCPH-1004
FCPH-1005
FCR Messages
FCR-1001
FCR-1002
FCR-1003
FCR-1004
FCR-1005
FCR-1006
FCR-1007
FCR-1008
FCR-1009
FCR-1010
FCR-1011
FCR-1012
FCR-1013
FCR-1015
FCR-1016
FCR-1018
FCR-1019
FCR-1020
FCR-1021
FCR-1022
FCR-1023
FCR-1024
FCR-1025
FCR-1026
FCR-1027
FCR-1028
FCR-1029
FCR-1030
FCR-1031
FCR-1032
FCR-1033
Fabric OS Message Reference
53-1002749-01
FCR Messages
2
FCR-1034
FCR-1035
FCR-1036
FCR-1037
FCR-1038
FCR-1039
FCR-1040
FCR-1041
FCR-1042
FCR-1043
FCR-1048
FCR-1049
FCR-1053
FCR-1054
FCR-1055
FCR-1056
FCR-1057
FCR-1058
FCR-1059
FCR-1060
FCR-1061
FCR-1062
FCR-1063
FCR-1064
FCR-1065
FCR-1066
FCR-1067
FCR-1068
FCR-1069
FCR-1070
FCR-1071
FCR-1072
FCR-1073
FCR-1074
FCR-1075
Fabric OS Message Reference
57
53-1002749-01
FICN Messages
2
FCR-1076
FCR-1077
FCR-1078
FCR-1079
FCR-1080
FCR-1081
FCR-1082
FCR-1083
FCR-1084
FCR-1085
FCR-1086
FCR-1087
FCR-1088
FCR-1089
FCR-1091
FCR-1092
FCR-1093
FCR-1094
FCR-1095
FCR-1096
FCR-1097
FCR-1098
FICN Messages
FICN-1003
FICN-1004
FICN-1005
FICN-1006
FICN-1007
FICN-1008
FICN-1009
FICN-1010
FICN-1011
FICN-1012
FICN-1013
Fabric OS Message Reference
53-1002749-01
FICN Messages
2
FICN-1014
FICN-1015
FICN-1016
FICN-1017
FICN-1018
FICN-1019
FICN-1020
FICN-1021
FICN-1022
FICN-1023
FICN-1024
FICN-1025
FICN-1026
FICN-1027
FICN-1028
FICN-1029
FICN-1030
FICN-1031
FICN-1032
FICN-1033
FICN-1034
FICN-1035
FICN-1036
FICN-1037
FICN-1038
FICN-1039
FICN-1040
FICN-1041
FICN-1042
FICN-1043
FICN-1044
FICN-1045
FICN-1046
FICN-1047
FICN-1048
Fabric OS Message Reference
59
53-1002749-01
FICN Messages
2
FICN-1049
FICN-1050
FICN-1051
FICN-1052
FICN-1053
FICN-1054
FICN-1055
FICN-1056
FICN-1057
FICN-1058
FICN-1059
FICN-1060
FICN-1061
FICN-1062
FICN-1063
FICN-1064
FICN-1065
FICN-1066
FICN-1067
FICN-1068
FICN-1069
FICN-1070
FICN-1071
FICN-1072
FICN-1073
FICN-1074
FICN-1075
FICN-1076
FICN-1077
FICN-1078
FICN-1079
FICN-1080
FICN-1081
FICN-1082
FICN-1083
Fabric OS Message Reference
53-1002749-01
FICN Messages
2
FICN-1084
FICN-1085
FICN-1086
FICN-1087
FICN-1088
FICN-1089
FICN-1090
FICN-1091
FICN-1092
FICN-1093
FICN-1094
FICN-1095
FICN-1096
FICN-1097
FICN-1098
FICN-1099
FICN-1100
FICN-1101
FICN-1102
FICN-1103
FICN-1104
FICN-1105
FICN-1106
FICN-1107
FICN-1108
FICN-1109
FICN-1110
FICN-1111
FICN-1112
FICN-1113
FICN-1114
FICN-1115
FICN-1116
FICN-1117
FICN-1118
Fabric OS Message Reference
61
53-1002749-01
FICU Messages
2
FICN-1119
FICN-1120
FICN-1121
FICN-1122
FICN-2005
FICN-2006
FICN-2064
FICN-2065
FICN-2066
FICN-2082
FICN-2083
FICN-2085
FICN-2086
FICN-2087
FICU Messages
FICU-1001
FICU-1002
FICU-1003
FICU-1004
FICU-1005
FICU-1006
FICU-1007
FICU-1008
FICU-1009
FICU-1010
FICU-1011
FICU-1012
FICU-1013
FICU-1017
FICU-1018
FICU-1019
FICU-1020
FICU-1021
FICU-1022
Fabric OS Message Reference
53-1002749-01
FKLB Messages
2
FICU-1023
FICU-1024
FKLB Messages
FKLB-1001
FLOD Messages
FLOD-1001
FLOD-1003
FLOD-1004
FLOD-1005
FLOD-1006
FSPF Messages
FSPF-1001
FSPF-1002
FSPF-1003
FSPF-1005
FSPF-1006
FSPF-1007
FSPF-1008
FSPF-1009
FSPF-1010
FSPF-1011
FSPF-1012
FSS Messages
FSS-1001
FSS-1002
FSS-1003
FSS-1004
FSS-1005
FSS-1006
FSS-1007
Fabric OS Message Reference
63
53-1002749-01
FSSM Messages
2
FSS-1008
FSS-1009
FSS-1010
FSS-1011
FSSM Messages
FSSM-1002
FSSM-1003
FSSM-1004
FW Messages
FW-1001
FW-1002
FW-1003
FW-1004
FW-1005
FW-1006
FW-1007
FW-1008
FW-1009
FW-1010
FW-1011
FW-1012
FW-1033
FW-1034
FW-1035
FW-1036
FW-1037
FW-1038
FW-1039
FW-1040
FW-1041
FW-1042
FW-1043
Fabric OS Message Reference
53-1002749-01
FW Messages
2
FW-1044
FW-1045
FW-1046
FW-1047
FW-1048
FW-1049
FW-1050
FW-1051
FW-1052
FW-1053
FW-1054
FW-1113
FW-1114
FW-1115
FW-1116
FW-1117
FW-1118
FW-1119
FW-1120
FW-1121
FW-1122
FW-1123
FW-1124
FW-1125
FW-1126
FW-1127
FW-1128
FW-1129
FW-1130
FW-1131
FW-1132
FW-1133
FW-1134
FW-1135
FW-1136
Fabric OS Message Reference
65
53-1002749-01
FW Messages
2
FW-1137
FW-1138
FW-1139
FW-1140
FW-1160
FW-1161
FW-1162
FW-1163
FW-1164
FW-1165
FW-1166
FW-1167
FW-1168
FW-1169
FW-1170
FW-1171
FW-1172
FW-1173
FW-1174
FW-1175
FW-1176
FW-1177
FW-1178
FW-1179
FW-1180
FW-1181
FW-1182
FW-1183
FW-1184
FW-1185
FW-1186
FW-1187
FW-1188
FW-1189
FW-1190
Fabric OS Message Reference
53-1002749-01
FW Messages
2
FW-1191
FW-1192
FW-1193
FW-1194
FW-1195
FW-1196
FW-1197
FW-1198
FW-1199
FW-1200
FW-1201
FW-1202
FW-1203
FW-1204
FW-1205
FW-1206
FW-1207
FW-1216
FW-1217
FW-1218
FW-1219
FW-1240
FW-1241
FW-1242
FW-1243
FW-1244
FW-1245
FW-1246
FW-1247
FW-1248
FW-1249
FW-1250
FW-1251
FW-1272
FW-1273
Fabric OS Message Reference
67
53-1002749-01
FW Messages
2
FW-1274
FW-1275
FW-1296
FW-1297
FW-1298
FW-1299
FW-1300
FW-1301
FW-1302
FW-1303
FW-1304
FW-1305
FW-1306
FW-1307
FW-1308
FW-1309
FW-1310
FW-1311
FW-1312
FW-1313
FW-1314
FW-1315
FW-1316
FW-1317
FW-1318
FW-1319
FW-1320
FW-1321
FW-1322
FW-1323
FW-1324
FW-1325
FW-1326
FW-1327
FW-1328
Fabric OS Message Reference
53-1002749-01
FW Messages
2
FW-1329
FW-1330
FW-1331
FW-1332
FW-1333
FW-1334
FW-1335
FW-1336
FW-1337
FW-1338
FW-1339
FW-1340
FW-1341
FW-1342
FW-1343
FW-1344
FW-1345
FW-1346
FW-1347
FW-1348
FW-1349
FW-1350
FW-1351
FW-1352
FW-1353
FW-1354
FW-1355
FW-1356
FW-1357
FW-1358
FW-1359
FW-1360
FW-1361
FW-1362
FW-1363
Fabric OS Message Reference
69
53-1002749-01
FW Messages
2
FW-1364
FW-1365
FW-1366
FW-1367
FW-1368
FW-1369
FW-1370
FW-1371
FW-1372
FW-1373
FW-1374
FW-1375
FW-1376
FW-1377
FW-1378
FW-1379
FW-1400
FW-1401
FW-1402
FW-1403
FW-1404
FW-1405
FW-1406
FW-1407
FW-1408
FW-1424
FW-1425
FW-1426
FW-1427
FW-1428
FW-1429
FW-1430
FW-1431
FW-1432
FW-1433
Fabric OS Message Reference
53-1002749-01
FW Messages
2
FW-1434
FW-1435
FW-1436
FW-1437
FW-1438
FW-1439
FW-1440
FW-1441
FW-1442
FW-1443
FW-1444
FW-1445
FW-1446
FW-1447
FW-1448
FW-1500
FW-1501
FW-1502
FW-1510
FW-1511
FW-1512
FW-1513
FW-1514
FW-1515
FW-1516
FW-1517
FW-1518
FW-1519
FW-1520
FW-1521
FW-1522
FW-1523
FW-1524
FW-1525
FW-1526
Fabric OS Message Reference
71
53-1002749-01
HAM Messages
2
FW-1527
FW-1528
FW-1529
FW-1530
FW-1531
FW-1532
FW-1533
FW-1534
FW-1535
FW-2000
FW-3010
FW-3011
FW-3012
FW-3013
FW-3014
FW-3015
FW-3016
FW-3017
FW-3018
FW-3019
FW-3020
FW-3021
FW-3022
HAM Messages
HAM-1001
HAM-1002
HAM-1004
HAM-1005
HAM-1006
HAM-1007
HAM-1008
HAM-1009
HAM-1010
HAM-1011
Fabric OS Message Reference
53-1002749-01
HAMK Messages
2
HAM-1013
HAM-1014
HAMK Messages
HAMK-1001
HAMK-1002
HAMK-1003
HAMK-1004
HIL Messages
HIL-1101
HIL-1102
HIL-1103
HIL-1104
HIL-1105
HIL-1106
HIL-1107
HIL-1108
HIL-1201
HIL-1202
HIL-1203
HIL-1204
HIL-1206
HIL-1207
HIL-1208
HIL-1301
HIL-1302
HIL-1303
HIL-1304
HIL-1305
HIL-1306
HIL-1307
HIL-1308
HIL-1309
Fabric OS Message Reference
73
53-1002749-01
HLO Messages
2
HIL-1310
HIL-1311
HIL-1401
HIL-1402
HIL-1403
HIL-1404
HIL-1501
HIL-1502
HIL-1503
HIL-1504
HIL-1505
HIL-1506
HIL-1507
HIL-1508
HIL-1509
HIL-1510
HIL-1511
HIL-1601
HIL-1602
HIL-1603
HIL-1605
HIL-1610
HIL-1611
HIL-1612
HIL-1613
HIL-1650
HLO Messages
HLO-1001
HLO-1002
HLO-1003
HMON Messages
HMON-1001
Fabric OS Message Reference
53-1002749-01
HSL Messages
2
HSL Messages
HSL-1000
HSL-1001
HSL-1002
HSL-1003
HSL-1004
HSL-1005
HSL-1006
HSL-1007
HTTP Messages
HTTP-1001
HTTP-1002
HTTP-1003
IBD Messages
IBD-1000
IPAD Messages
IPAD-1000
IPAD-1001
IPAD-1002
IPAD-1003
IPAD-1004
IPS Messages
IPS-1001
IPS-1002
IPS-1003
IPS-1004
IPS-1005
IPS-1006
IPS-1007
Fabric OS Message Reference
75
53-1002749-01
ISNS Messages
2
ISNS Messages
ISNS-1001
ISNS-1002
ISNS-1003
ISNS-1004
ISNS-1005
ISNS-1006
ISNS-1008
ISNS-1009
ISNS-1010
ISNS-1011
ISNS-1013
ISNS-1014
KAC Messages
KAC-1002
KAC-1004
KAC-1006
KAC-1007
KAC-1008
KAC-1009
KAC-1010
KAC-1011
KAC-1012
KAC-1013
KAC-1014
KAC-1015
KAC-1016
KAC-1017
KSWD Messages
KSWD-1001
KSWD-1002
Fabric OS Message Reference
53-1002749-01
KTRC Messages
2
KTRC Messages
KTRC-1001
KTRC-1002
KTRC-1003
KTRC-1004
KTRC-1005
L2SS Messages
L2SS-1001
L2SS-1002
L2SS-1003
L2SS-1004
L2SS-1005
L2SS-1006
L2SS-1007
L2SS-1008
L3SS Messages
L3SS-1004
LACP Messages
LACP-1001
LACP-1002
LANCE Messages
LANCE-1000
LFM Messages
LFM-1001
LFM-1002
LFM-1003
LFM-1004
LFM-1005
Fabric OS Message Reference
77
53-1002749-01
LOG Messages
2
LFM-1006
LOG Messages
LOG-1000
LOG-1001
LOG-1002
LOG-1003
LOG-1004
LOG-1005
LOG-1006
LOG-1007
LOG-1008
LOG-1009
LOG-1010
LOG-1011
LSDB Messages
LSDB-1001
LSDB-1002
LSDB-1003
LSDB-1004
MCAST_SS Messages
MCAST_SS-1001
MCAST_SS-1002
MCAST_SS-1003
MCAST_SS-1004
MCAST_SS-1005
MCAST_SS-1006
MCAST_SS-1007
MCAST_SS-1008
MCAST_SS-1009
MCAST_SS-1010
MCAST_SS-1011
Fabric OS Message Reference
53-1002749-01
MFIC Messages
2
MCAST_SS-1012
MCAST_SS-1013
MCAST_SS-1014
MCAST_SS-1015
MCAST_SS-1016
MCAST_SS-1017
MCAST_SS-1018
MCAST_SS-1019
MCAST_SS-1020
MFIC Messages
MFIC-1001
MFIC-1002
MFIC-1003
MM Messages
MM-1001
MPTH Messages
MPTH-1001
MPTH-1002
MPTH-1003
MQ Messages
MQ-1004
MQ-1005
MQ-1006
MS Messages
MS-1001
MS-1002
MS-1003
MS-1004
MS-1005