Central Heating Programmable Room ThermoStat

The Horstmann CentaurStat 1 is a programmable room thermostat that provides precise temperature control from a single point with up to 6 different temperature settings possible over a 24 hour cycle. Temporary temperature adjustments can be made by means of the temperature override buttons on the front of the unit. CentaurStat 1 User Operating Instructions 1

Horstmann CentaurStat 1 The CentaurStat 1 Programmable ThermoStat

The simple instructions contained in this user guide are designed to help with the programming and operation of the unit. 1 SET indicator 2 SET positions 3 SET button 4 OVERRIDE (MINUS) button 5 OVERRIDE (PLUS) button 6 ENTER button 7 Time or current temperature display 8 Target temperature 9 System ON symbol 10 PM indicator (no display for AM) 11 Temperature lock symbol 1 7 2 9 4 3 5 6 8 11 10 Located under fl

Horstmann CentaurStat 1 Target Temperature Override

Where an override temperature has been set, this altered setting will remain until the next time and temperature setting is reached. Target Temperature Lock The temperature lock facility allows you to ‘lock in’ the target or override temperature of the current heating period. With the SET indicator in the RUN position press the ENTER button. The temperature lock symbol will appear on the right hand side of the display. All c

Setting the Time of Day

When setting the time or altering the temperature settings, if a period exceeding 65 seconds is allowed to elapse between button presses then the CentaurStat will automatically return to the run position. Any alterations made since the last press of the ENTER button will not be recognised. Time and Temperature Settings The CentaurStat 1 has six temperature settings per 24 hours. These all have different start times and temperature s

Horstmann CentaurStat 1 Changing the Times and Target Temperatures

Press the SET button until SET indicator is next to the PROG position The time setting for the 1st period will now flash. Use the PLUS and MINUS buttons to alter the start time if required Repeat for remaining 5 time and temperature periods Press the SET button until the SET indicator is returned to the RUN position The target temperature setting for the 1st period will now flash. Use the PLUS and MINUS buttons to

Reducing the Number of Time and

Temperature Settings To reduce the number of temperature settings available in a day from six to four, proceed as follows: Set the 3 and 4 period temperatures to the same temperature as set on period 2. Periods 1 and 2 will now operate as normal. For two settings per day, set the temperature on periods 2, 3, 4 and 5 to the same temperature as set on period 1. For one setting per day use the Target Temperature Lock procedure

Resetting the CentaurStat

Electronic equipment can in some circumstances be affected by electrical interference. If the programmer’s display becomes frozen or scrambled; or if you wish to revert back to the default time settings please use the following procedure. Lower the flap and press the SET and ENTER buttons together, release the buttons and the CentaurStat will return to preset factory default time settings. Service and Repair This product is NO

Horstmann Controls Limited, Bristol BS4 1UP

Leaflet number P82161 – Issue 2 8 ... an explantion for householders. A programmable room thermostat is both a programmer and a room thermostat. A programmer allows you to set ‘ON and OFF’ time periods to suit your own lifestyle. A room thermostat works by sensing the air temperature, switching on the heating when the air temperature falls below the

Horstmann Thermostat Owners Instructions: