About this Manual

We’ve added this manual to the Agilent website in an effort to help you support your product. This manual is the best copy we could find; it may be incomplete or contain dated information. If we find a more recent copy in the future, we will add it to the Agilent website. Support for Your Product Agilent no longer sells this product. Our service centers may be able to perform calibration and repair if necessary, but no other support from Agilent is available. You will find any other available product information on the Agilent Test & Measurement website, www.tm.agilent.com. HP References in this Manual This manual may contain references to HP or Hewlett-Packard. Please note that Hewlett-Packard's former test and measurement, semiconductor products and chemical analysis businesses are now part of Agilent Technologies. We have made no changes to this manual copy. In other documentation, to reduce potential confusion, the only change to product numbers and names has been in the company name prefix: where a product number/name was HP XXXX the current name/number is now Agilent XXXX. For example, model number HP8648A is now model number Agilent 8648A.

This literature was published years prior to the establishment of

Agilent Technologies as a company independent from Hewlett-Packard and describes products or services now available through Agilent. It may also refer to products/services no longer supported by Agilent. We regret any inconvenience caused by obsolete information. For the latest information on Agilent's test and measurement products go to: www.agilent.com find products Or in the US, call Agilent Technologies at 1-800-452-4844 (8am-8pm EST)

for the HP 4142B.

The manual consists of the following chapters and appendixes: Chapter 1 Installation Contains initial inspection and installation information necessary to know before apply- ing ac power. Chapter 2 Overview Shows product overview. Chapter 3 Test Device Connections Shows how to connect the test device to the HP 4142B. Chapter 4 Operation Guide Shows how to turn the HP 4142B on, how to send commands to the HP 4142B, how to force and measure voltage and current, and how to retrieve measurement data. This chapter will help you quickly learn to operate the HP 4142B. Chapter 5 Measurement Modes Describes the types of measuremente 3, such as spot, sweep, and pulsed measurements. Chapter 6 Measurement Functions Describes the functions that can be used in measurements, such as ranging, com- pliance, measurement averaging, automatic sweep abort function, and program memory. Chapter 7 Miscellaneous Functions Describes the functions that are not directly related to the measurements, such as the front and rear panels, query commands, and the functions at power-on. Appendix A Manual Changes Contains the information needed to use this manual with an HP 4142B that was man- ufactured before the printing date of this manual. Appendix B Specifications Contains the specification and reference data of the HP 4142B. Appendix C Accessories and Options Contains the accessories and options lists. This manual does not contain detailed descriptions of each HP 4142B command, measure- ment data output format, and error messages. Refer to the HP-ZB Command R~~wuw~ Manrral for more detailed information on these topics.

CHAPTER 1 INSTALLATION

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . l-l Initial Inspection . . . . . . . . .*..*.* . . . . . . . . . . . . . . . . . . . . . . . . . . . . l-l Installing the HP 4142B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . l-2 Installing the Blank Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . l-2 Installing the Front Panel ................................. l-2 Line Power Requirements .......... ......... ......... ........ l-2 Line Voltage and Fuse Selection ..................... .... ... l-3 Setting the Line Frequency FILTER Switch ............... .... l-3 Power Cables ............................................... l-4 Grounding Requirements ..................................... l-5 Changing the HP-IB Address ................................. l-5 Connecting the HP-IB Cable ................................. l-5 Mounting the HP 4142B .................... ....... .... .*.*.** 1 6 Operating Environment ...................................... 117 Installing and Removing Plug-in Units ........... ............. l-8 Storage and Shipment ........... ..... ....... ........ .... ...... l-9 Environment .................................... .*** ..* ..... l-9 Original Packaging ......................................... 1-9 Other Packaging ............................................ l-9 Repair Service ............................................... l-10 Serial Number .............................................. l-10 CHAPTER 2 OVERVIEW Introduction ................................................. 2-l Product Introduction ......................................... 2-1 HP 4142B ................................................... 2-l Ground Unit (GNDU) ......................... ...... .......... 2-3 HP 41420A HPSMU and HP 41421B MPSMU ........................ 2-4 HP 41422A HCU .............. ...... .......... ...... ..... ................................................... 27 HP 41423A HVU 2:9 HP 41424A VS/VMU ...................................... ..... 2-11 HP 41425A AFU .............................................. 2-13 Measurement Modes .......................................... 2-14 Total Power Limitation of Plug-in Units .................... 2-16 Panel Overview ............................................... 2-17 CHAPTER 3 TEST DEVICE CONNECTIONS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-l Before Connecting Test Devices . . l . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-l Enclose the Test Device with a Shielding Box .b.b..... bbb... 3-l Connect the INTLK Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Shorting Circuit Common and Chassis Ground Terminals . l l . . . . 3-4 Connecting the Test Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 GNDU Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 HPSMU and MPSMU Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 HCU Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12 HVU Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17 VS/VMU Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22 i

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23

Using Connector Plate Part Number 04142-60021 . . . . . . . . . . . . . . 3-23 Using Connector Plate Part Number 04142-60032 . . . . . . . . . . . . . . 3-24 Using Connector Plate Part Number 16087-60002 . . . . . . . . . . . . . . 3-25 ' Using the HP 16088B Test Fixture . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-26 Using the HP 16058A Test Fixture . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-31 Using the HP 16087A Module Selector . . . . . . . . . . . . . . . . . . . . . . . . 3-33 Cable Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-42 Advanced Connection Information l ~~~~~~~i..~~~~~~~..~.~~~~.~~. 3-45 For High Current Measurements (Kelvin Connection) . . . . . . . . . . 3-45 For Low Current Measurements (Using the GUARD Terminal) . . . . 3-47 If the Test Device is Externally Grounded (Floating Measurement) . . . . 3-48 If the Test Device has Negative Resistance . . . . . . . . . . . . . . . . . 3-50 Preventing Oscillation from the Test Device . . . . . . . . . . . . . . . . 3-51 CHAPTER 4 OPERATION GUIDE Introduction ........................................... ...... 4-l Before Applying Power ............ ....... l **a** . . l l *e**** . . l l l 4-1 Safety Precautions .............................. .... ....... 4-l Confirming Installation .................................... 4-3 Applying Power ............................................... 4-4 Self-Test .................................................. 4-4 Performing Safety Tests for the HVU .......................... 4-5 Sending the HP-IB Command .................................... 4-6 Output/Input Statement ..................................... 4-6 Sending an HP-IB Command .~.~.~~~~.~~.~~..~~~~.~~~~~~..~~~~ l 4-6 Sending an HP-IB Command to the Unit (Channel Numbers; Ch#) 4-7 Getting Data from the HP 4142B ............................. 4-7 If an Error Occurs .~.~~~~~~~~~~~~~~~~~~~~.~~~~~~~~~~.~.~~~~~~ 4-8 Reading the Error Register ............................ . . l . . 4-8 Resetting the HP 4142B ........................... ............ 4-9 Forcing and Measuring ........................................ 4-10 Performing the Self-Calibration l .~.~~~~~~~~~~~~.~~~~..~~~~ l 4-10 Setting the Output Switch of the Unit to ON ................ 4-11 Setting the Output Switch of the Unit to OFF ............... 4-11 Forcing Constant Voltage ................................... 4-12 Forcing Constant Current ................................... 4-13 Setting the Output to 0 V .................................. 4-14 Performing the Measurement l ..~~~~~~~~.~.~.~.~~~~.~~~~~.~ ..* 4-15 Performing the Staircase Sweep Measurement ................. 4-16 Specifying the Measurement Range ........................... 4-17 Measurement Program Flow ................................... 4-18 Waiting for Time ...................................... l . l . . 4-19

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-l

Spot Measurements ............................................ 5-l Commands and Parameters .................................... 5-3 Information ................................................ 5-3 Spot Measurement Sample Program ............................ 5-4 Staircase Sweep Measurements ................................. 5-6 Commands and Parameters .................................... 5-10 Information ................................ ................ 5-11 Staircase Sweep Measurement Sample Program ................. 5-11 lch Pulsed Spot Measurements ................................. 5-15 Commands and Parameters .................................... 5-18 Information ................................................ 5-18 lch Pulsed Spot Measurement Sample Program ................. 5-19 Pulsed Sweep Measurements .................................... 5-21 Commands and Parameters .......... .......................... 5-25 Information ................................................ 5-26 Pulsed Sweep Measurement Sample Program .................... 5-26 Staircase Sweep with Pulsed Bias Measurements ................ 5-29 Commands and Parameters ........................ ............ 5-33 Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-34 Staircase Sweep with Pulsed Bias Measurement Sample Program 5-34 Analog Search Measurements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-37 Search Operation Modes . . . ..*t*.. . . . . . . . . l . . . . ..e . . . . . . . . . . . 5-40 Search Measurement Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . l . . 5-42 Commands and Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-43 AFU Monitor Port ........................................... 5-44 Information ....................................... ......... 5-45 Analog Search Measurement Sample Program ................... 5-45 2ch Pulsed Spot Measurements ......................... ........ 5-48 Commands and Parameters .................................... 5-51 Information ................................................ 5-52 2ch Pulsed Spot Measurement Sample Program ......... ........ 5-52 Pulsed Sweep with Pulsed Bias Measurements ................... 5-54 Commands and Parameters ................. ................... 5-58 Information .......... ................. ..... ................ 5-59 Pulsed Sweep with Pulsed Bias Measurement Sample Program ... 5-59 Quasi-Pulsed Spot Measurements ............................... 5-63 Settling Detection Method .................................. 5-68 Commands and Parameters ....... .......... ... ................ 5-70 Information ................................................ 5-70 Quasi-pulsed Spot Measurement Sample Program ............... 5-71 High Speed Spot Measurements ................................. 5-73 Commands and Parameters .................................... 5-75 Information ................................................ 5-75 High Speed Spot Measurement Sample Program ................. 5-76

CHAPTER 6 MEASUREMENT

FUNCTIONS Introduction ................................................. 6-l Output Ranging Mode ................................. . ......... 6-l Allowable Ranging Mode ..................................... 6-l Auto Ranging ............................................... 6-2 Limited Auto Ranging ....................................... 6-3 Measurement Ranging Mode ..................................... 6-4 Allowable Ranging Mode ..................................... 6-4 Auto Ranging ............................................... 6-5 Limited Auto Ranging ....................................... 6-6 Compliance Range ........................................... 6-6 Fixed Range ................................................ 6-7 Note ....................................................... 6-8 Compliance/Limiter ........................................... 6-9 V/I Compliance ............................................. 6-9 Power Compliance ........................................... 6-17 Limiter .................................................... 6-18 Averaging .................................................... 6-19 Filter ....................................................... 6-21 Automatic Sweep Abort Function ............................... 6-22 Output After Sweep ........................................... 6-22 Measurement Data Memory ...................................... 6-23 Program Memory ............................................... 6-24 Using Program Memory ....................................... 6-27 Program Memory Sample Program .............................. 6-28 Using the HP 4142B with External Instruments ................. 6-30 Trigger Output and Input Function .......................... 6-30 Triggering an External Instrument .......................... 6-30 Externally Triggered HP 4142B Measurements ................. 6-31 Waiting for Trigger Signal from TRIGGER INPUT Terminal ..... 6-31 Waiting for Time or Trigger ................................ 6-33 Waiting for Command Execution Completion (*OPC? Command) ... 6-33 Relay Control (Option 300) ................................... 6-34 Module Selector Control .................................... 6-34 External Relay Control ..................................... 6-35 CHAPTER 7 MISCELLANEOUS FUNCTIONS Introduction . Front and Rear Front Panel Rear Panel . Query Commands HP-IB Capabili Status Byte . . Status . . . . . Commands . . . Status Byte Self-Calibrati Self-Calibra 7-l 'paneis'::::::::::::::::::::::::::::::::::::: 7-1 ................................................ 7-l ................................................ 7-8 ............................................... 7-9 tY ............................................. 7-10 ................................................ 7-11 ................................................ 7-11 ................................................ 7-12 Sample Program ................................. 7-13 on/Self-Test ................................... 7-18 tion ........................................... 7-18 Auto-Calibration ........................................... 7-19 Self-Test .................................................. 7-20 Initial Settings ............................................. 7-21 Auto Power Off Function l ,.~.~,~~~~.~~~~~~~~~~~~~~~~~~~~~~.~.~ 7-24 iv

. . . . . . .

Appendix C, Accessories and Options . . . . . . . . . . ..,... l ****e***. C-l