HP ProLiant DL585 Quickspecs
Read Online
Read the HP ProLiant DL585 Quickspecs online using the built-in PDF viewer.
Text of the manual
1. Eight 64-bit PCI-X I/O Slots (Six 100MHz, two 133MHz)
2. 2 or 4 processors/memory boards
3. 2 or 4 AMD Opteron 800 Series Processors
4. Up to 64GB of PC2700 DDR SDRAM with Advanced ECC,
running at 266MHz, 48GB of PC2700 running at 333MHz or
32GB of PC3200 running at 400MHz
5. Hot Plug Redundant Fans (standard)
6. 4U (7" Height) Rack Form Factor
7. Tool-less "Snap In" rail solution
8. Server Lifting Handle
9. Front Panel LED Display (internal and external health, Unit ID
light) and Power Button
10. Ultra320 Drive Cage, capable of simplex or duplex
configuration)
11. Dual 870-Watt Hot Plug Redundant Power Supplies (hi/lo
line auto-sensing
12. Two Universal Media Bays: 24X CD-ROM IDE and 1.44 MB
Diskette Drive (standard)
13. Multi-Bay floppy and CD-ROM drives, standard on most
models
14. QuickFind Diagnostic Display (viewable through the Top
Access Panel)
15. Removable Top Access Panel
16. Integrated Lights-Out (iLO)- not shown
17. Dual Port NC7782 embedded NIC - not shown
What's New
What's New
What's New
What's New
Support for AMD Opteron Model 852 processors with PC2700
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Overview
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 1
At A Glance
At A Glance
At A Glance
At A Glance
Delivering maximum performance in a versatile, rack optimized form factor
AMD Opteron 800 series running at 2.6 GHz, 2.4 GHz or 2.2 GHz single core processors (two or four supported)
AMD Opteron 8000 chipset supporting up to 1GHz HyperTransport
4GB of PC3200 DDR SDRAM, running at 400MHz, expandable to 32GB, or 2GB of PC2700 DDR SDRAM, running at
333MHz, expandable to 64 GB with support for PC2700 DDR with Advanced ECC SDRAM (48 GB running at 333MHz or
64GB running at 266MHz)
NOTE:
NOTE:
NOTE:
NOTE: 1.8 GHz, 2.2 GHz sku's still ship with PC2100 memory.
Eight full length 64-bit PCI-X slots, 6 100MHz, 2 133MHz
Integrated Lights-Out Standard Management (iLO) on system board
Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network adapter
Integrated Smart Array 5i Plus Controller (Dual Channel, Ultra3) with 64-MB total memory on 5i Plus Memory Module
Transportable Battery-Backed Write Cache Enabler module (depending on model)
Multi-Bay floppy and CD-ROM drives
Internal Hot Plug Drive Storage of up to 1.20 TB (4 x 300 GB Ultra320 SCSI 1" hard drives)
Redundant hot plug power supplies and fans
Tool-less and virtually cable-less internal design
Innovative diagnostic lighting (QuickFind Diagnostic Display) for rapid response to service events
Rapid Deployment racking solution (rack rails and cable management)
Protected by HP Services, including a three-year, Next Business Day on-site, limited, Global warranty and extended Pre-Failure
Warranty that covers processors, memory and disk drives - Certain restrictions and exclusions apply.
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Overview
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 2
Two or four of the
following depending on
Model
AMD Opteron model 852, running at 2.6 GHz (2 or 4 supported)
AMD Opteron model 850, running at 2.4 GHz (2 or 4 supported)
AMD Opteron model 848, running at 2.2 GHz (2 or 4 supported)
Cache Memory
Cache Memory
Cache Memory
Cache Memory
1-MB Integrated Level 2 Cache
Upgradability
Upgradability
Upgradability
Upgradability
Upgradable to quad processing
Chipset
Chipset
Chipset
Chipset
AMD Opteron 8000 series chipset
Memory Protection &
Memory Protection &
Memory Protection &
Memory Protection &
Functionality
Functionality
Functionality
Functionality
Advanced ECC
Memory
Memory
Memory
Memory
Type
PC2100 DDR SDRAM, running at 266MHz
PC2700 DDR SDRAM, running at 333MHz
PC3200 DDR SDRAM, running at 400MHz
Standard
2 GB (2 x 512 MB x 2 Processor Boards) (PC2100 or PC2700DDR SDRAM)
4 GB (2 x 1024 MB x 2 Processor Boards) (PC3200 DDR SDRAM)
Maximum
32 GB (PC3200 DDR SDRAM)
64 GB (PC2100 or PC2700DDR SDRAM)
NOTE:
NOTE:
NOTE:
NOTE: PC2700 only supported on 2.4GHz and faster single core models and all
dual core models. Also PC3200 only supported on 2.6GHz single core models and
dual core models.
Network Controller
Network Controller
Network Controller
Network Controller
Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network adapter
Expansion Slots
Expansion Slots
Expansion Slots
Expansion Slots
Bus speed
Bus speed
Bus speed
Bus speed
Bus number
Bus number
Bus number
Bus number
Hot Plug
Hot Plug
Hot Plug
Hot Plug
PCI Voltage
PCI Voltage
PCI Voltage
PCI Voltage
1
64-bit / 133 MHz PCI-X
5
No
3.3 Volt
2
64-bit / 133 MHz PCI-X
6
No
3.3 Volt
3
64-bit / 100 MHz PCI-X
7
No
3.3 Volt
4
64-bit / 100 MHz PCI-X
7
No
3.3 Volt
5
64-bit / 100 MHz PCI-X
8
No
3.3 Volt
6
64-bit / 100 MHz PCI-X
8
No
3.3 Volt
7
64-bit / 100 MHz PCI-X
3
No
3.3 Volt
8
64-bit / 100 MHz PCI-X
3
No
3.3 Volt
NOTE:
NOTE:
NOTE:
NOTE: For more information regarding PCI-X, please see the following URL: http://www.hp.com/servers/pci-x
NOTE:
NOTE:
NOTE:
NOTE: All slots can accept universal keyed PCI cards.
Default bus assignment. Inserting cards with PCI bridges may alter the actual bus assignment number.
Slots are enumerated differently based on the operating system. Microsoft operating systems enumerate from lowest to highest
Device ID by bus (starting with the lowest bus).
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Standard Features
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 3
Integrated Lights-Out (iLO) Standard Management (ASIC on the System Board)
Storage Controllers
Storage Controllers
Storage Controllers
Storage Controllers
Smart Array 5i Plus Controller (integrated on system board), Dual Channel, Ultra3 (supports RAID 0, 1,
1+0, and 5 across internal hard disk drives) with 64 MB of memory.
64-MB total memory for code, transfer buffers, and read/write cache on the 5i Plus Memory
Module
Connector for Battery Backed Write Cache (BBWC) Enabler
NOTE:
NOTE:
NOTE:
NOTE: The Smart Array 5i Plus Controller is integrated on the system board and is designed to support
the duplex/simplex drive cage. An external SCSI port is not available on the HP ProLiant DL585. External
SCSI solutions require the addition of a PCI or PCI-X option card.
Storage Data Protection
Storage Data Protection
Storage Data Protection
Storage Data Protection
The Battery-Backed Write Cache (BBWC) Enabler protects up to 64-MB write cache memory from hard
boot, power, controller, or system board failures.
Standard on all HP ProLiant DL585 Models
Battery charge/life: Up to 72 hours/3 years
Transportable data protection
Increases overall controller performance
NOTE:
NOTE:
NOTE:
NOTE: Safely transport your write cache data to another HP ProLiant DL585 in the data center by
removing the BBWC Enabler and 5i Plus Memory Module simultaneously (connected by short cable).
Storage
Storage
Storage
Storage
Diskette Drive
1.44 MB Diskette Drive (slim line) – ejectable for security and serviceability
Optical Drive
24x IDE CD-ROM Drive (slim line) – ejectable for security and serviceability
Hard Drives
None
Hard Disk Drive
Backplane
Internal Wide Ultra3 backplane supports up to four 1" hard disk drives and is
easily configurable to support simplex (4x1) or duplex mode (2x2) Standard
shipping configuration is the duplex mode.
NOTE:
NOTE:
NOTE:
NOTE: Optional SCSI cable assembly 365483-B21 is required for
connecting Smart Array Controller in a PCI slot to internal hard drive
backplane. Duplex configuration requires two such kits.
Maximum Internal
Maximum Internal
Maximum Internal
Maximum Internal
Storage Type
Storage Type
Storage Type
Storage Type
Hot Plug SCSI
1.20 TB
4 x 300 GB Ultra320 1" drives (internal hot plug
Ultra3 or Ultra320 drive cage)
Interfaces
Interfaces
Interfaces
Interfaces
Serial
1
Pointing Device (Mouse)
1
Graphics
1
Keyboard
1
Rear USB Ports
2
iLO Remote Management 1
Network RJ-45
2
Graphics
Graphics
Graphics
Graphics
Integrated 1280 x 1024, 16M color on PCI local bus, 8 MB of SDRAM video memory
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Standard Features
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 4
Rack (4U = 7 inches), ships with sliding rails and cable management system
Space saving form factor (4U) provides space efficiencies while providing maximum deployment
flexibility
ProLiant
ProLiant
ProLiant
ProLiant Essentials
Essentials
Essentials
Essentials
Foundation Pack
Foundation Pack
Foundation Pack
Foundation Pack
Software
Software
Software
Software
HP Systems Insight
Manager
HP's new HP Systems Insight Manager (HP SIM) helps maximize system
uptime and performance and reduce system maintenance costs by providing
proactive notification of problems before those problems result in unplanned
downtime or reduced productivity. HP SIM are both easy to set up work with
the Insight Management Agents, integrated Light-Out and Remote Insight
Light-Outs Edition, and Version Control Agents to deliver robust fault,
configuration, and asset management as well as remote administration. With
HP SIM customers will also be able to take advantage of role-based security;
the ability to manage ProLiant, Integrity, and HP 9000 systems; and plug-ins
for storage, client, printer, and power management as well as server rapid
deployment, performance management, and workload management. For
more details on HP HP SIM visit http://www.hp.com/go/hpsim.
SmartStart
SmartStart is a tool that simplifies server setup, providing a rapid way to
deploy reliable and consistent server configurations. For more information,
please visit the SmartStart Web site at http://www.hp.com/servers/smartstart.
SmartStart version supported (minimum): SmartStart 7.00.
Management Agents
The Management Agents form the foundation for HP's Intelligent
Manageability strategy. They provide direct, browser-based access to in-
depth instrumentation built into HP servers, workstations, desktops, and
portables, and send alerts to HP Systems Insight Manager and other
enterprise management applications in case of subsystem or environmental
failures. For additional information about the Management Agents and other
management products from HP, please visit the management Web site at
http://www.hp.com/servers/manage.
Subscriber's Choice
Subscriber's Choice Driver and Support Alerts/Notifications is a web-based
email subscription service that provides automatic delivery of software and
driver change notifications for ProLiant products. Sign up at
http://www.hp.com/go/subscriberschoice
and customize your profile to receive various new alerts as they become
available, on a weekly or monthly basis.
ROMPaq, support
software, and
configuration utilities
The latest software, drivers, and firmware fully optimized and tested for your
ProLiant server and options available in SmartStart or downloadable from
Software and Drivers download pages, linked from the SmartStart website at
http://www.hp.com/servers/smartstart.
Survey Utility and
diagnostics utilities
The most advanced configuration analysis, reporting and troubleshooting
utilities used by HP and at your fingertips, available in SmartStart.
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Standard Features
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 5
Essentials Value Packs
Optional software offerings that selectively extend the functionality of an
Adaptive Infrastructure to address specific business problems and needs:
Rapid Deployment Pack - an automated solution for multi-server
deployment and provisioning, enabling companies to quickly and
easily adapt to changing business demands.
Workload Management Pack - provides easier management of
complex environments, improving overall server utilization and
enabling Windows® 2000 customers for the first time to confidently
deploy multiple applications on a single multiprocessor ProLiant
Server.
Integrated Lights-Out Advanced Pack - upgrades the Integrated Lights-
Out processor to full virtual presence and control with graphical
console and virtual media.
Performance Management Pack - a performance management
solution that identifies and explains hardware performance bottlenecks
on ProLiant servers and attached options enabling users to better
utilize their valuable resources.
Intelligent Networking Pack - detects and analyzes network bottlenecks
or broken network linkages and steers traffic to the optimum route
based on network conditions.
Vulnerability and Patch Management Pack - identifies and remediates
software security vulnerabilities due to missing patches as well
operating system configurations that can be exploited by viruses,
worms, and other blended threats.
Virtual Machine Management Pack - provides central management
and control of virtual machines from Microsoft and VMware.
Integrated approach provides the ability to manage both physical and
virtual resources from a single management console.
NOTE:
NOTE:
NOTE:
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to
http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product
QuickSpecs for more information.
NOTE:
NOTE:
NOTE:
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL:
http://www.hp.com/servers/proliantessentials.
Industry Standard
Industry Standard
Industry Standard
Industry Standard
Compliance
Compliance
Compliance
Compliance
ACPI 1.0a. Compliant
PCI 2.2 Compliant
PXE Support
WOL Support
Physical Address Extension (PAE) Support
Microsoft® Logo certifications
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Standard Features
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 6
Integrated Lights-Out (iLO) Standard Management
Virtual Text Remote Console
Virtual Power Button Control
Dedicated LAN Connectivity
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) Security
IML and iLO Event Logging
Support for 12 user accounts with customizable access privileges
Integrated Lights-Out (iLO) Advanced Pack (supports Advanced features such as Graphical Remote
Console and Virtual Floppy - available as a separate option)
Intelligent Manageability
Intelligent Manageability
Intelligent Manageability
Intelligent Manageability
Automatic Server Recovery-2 (ASR-2)
HP Systems Insight Manager
Redundant ROM
Remote Flash ROM
ROM-Based Setup Utility (RBSU)
Integrated Management Log (IML)
Dynamic sector repairing and drive parameter tracking (with Smart Array controllers)
Redundant/adaptive load balancing NIC Support
Availability
Availability
Availability
Availability
Smart Array 5i Plus Controller with standard Battery Backed Write Cache (BBWC) Enabler
provides transportable data protection and increases overall controller performance. Up to 64MB
Battery Backed Write Cache protection available on 2P HP ProLiant DL585 models.
Up to four Hot Plug Ultra3 or Ultra320 Hard Drives
Duplex or Simplex SCSI Backplane (Duplex configuration is standard)
Dual Hot Plug Redundant Power Supplies (standard)
PCI-X Technology (six 64-bit/100-MHz and two 64-bit/133MHz PCI-X slots available)
Smart Array 5i Plus Controller with 64GB of Battery Backed Write Cache (BBWC) Enabler
provides transportable data protection and increases overall controller performance.
Fans are 7+1 hot plug redundant and individually removable.
Serviceability
Serviceability
Serviceability
Serviceability
Innovative Diagnostic Lighting
QuickFind Diagnostic Display - precisely depicts all major subsystems of the server (PCI-X I/O,
Memory, CPU, Redundant Cooling, Interlock, Thermtrip) and gives instant visual indication of fault
status. Located on top front of server.
Tool-less, virtually cable-less interior design
Tool-less access to interior of server
Two ejectable, Universal Media Bay media drives (diskette and CD-ROM standard with
support for optional DVD-ROM drives) are removable without the use of tools
Front access power supplies
PCI Card Guides locks full length PCI cards in place during transit
SCSI Duplex/Simplex Drive Cage connects directly to system board - no cables.
NOTE:
NOTE:
NOTE:
NOTE: Configure your SCSI Duplex/Simplex Drive Cage by means of simple switch (duplex
to simplex)
located on the cage itself. System ships standard in Duplex mode.
Eight individually removable fans connect without cables to the system board
Tool-less removal of system board
Quick Deploy Rails
Tool-less design "snap in" rail
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Standard Features
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 7
Diskette drive control
Diskette boot control
Network Server Mode
Serial interface control
Administrator's password
Disk configuration lock
Removable Diskette drive
Removable CD-ROM drive
Power Supply
Power Supply
Power Supply
Power Supply
Dual 870-Watt Hot Plug Redundant Power Supplies (hi/lo line auto-sensing)
System Fans
System Fans
System Fans
System Fans
Standard
8 Hot plug, redundant fans (individually removable)
Maximum
8 Hot plug, redundant fans (individually removable)
NOTE:
NOTE:
NOTE:
NOTE: A single cooling zone across the major server subsystems (Memory, I/O, CPU) providing 7x24
cooling in an N + 1 redundant configuration.
Required Cabling
Required Cabling
Required Cabling
Required Cabling
For required cabling information, refer to the HP Web site at
http://h18000.www1.hp.com/products/servers/proliantDL585/
OS Support
OS Support
OS Support
OS Support
Microsoft Windows 2000 Server
Microsoft Windows 2000 Advanced Server
Windows Server 2003, Standard Edition
Windows Server 2003, Enterprise Edition
Red Hat Enterprise Linux 3
Red Hat Enterprise Linux 4
SuSE Linux Enterprise Server 8
SuSE Linux Enterprise Server 9
NOTE:
NOTE:
NOTE:
NOTE: 2.2 GHz, 2.4 GHz and 2.6 GHz models.
NOTE:
NOTE:
NOTE:
NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our OS
Support Matrix at: http://www.hp.com/go/supportos.
NOTE:
NOTE:
NOTE:
NOTE: For an up-to-date listing of the latest drivers available for the HP ProLiant DL585, please see:
http://www.hp.com/support/files/server/us/index.html.
NOTE:
NOTE:
NOTE:
NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux Web
site at http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html.
NOTE:
NOTE:
NOTE:
NOTE: For more complete and up-to-date information on how to buy server operating systems from HP
please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html.
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Standard Features
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 8
Rack 10000 series Cabinets
Rack 10000 series Cabinets
Rack 10000 series Cabinets
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling
efficiency for rack-mounted servers. The 10000 Series Racks provide enhanced airflow for maximum
cooling, allowing these racks to be fully loaded with servers using the latest processors.
CAUTION:
CAUTION:
CAUTION:
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure
adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you
must allow 5,350 sq cm (830 square inches) of hole evenly distributed from top to bottom
to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack
must be a minimum of 7 cm (2.75 inches).
CAUTION:
CAUTION:
CAUTION:
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This
arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling
that can lead to thermal damage.
NOTE:
NOTE:
NOTE:
NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD
provided with the server, or to the server documentation located in the Support section at the following
URL: http://www5.hp.com/products/servers/proliantdl585/index.html.
Rack Mounting
Rack Mounting
Rack Mounting
Rack Mounting
Requirements
Requirements
Requirements
Requirements
HP ProLiant DL585 rack models provide tool-free support for square hole racks (including Compaq/HP
7000, 9000, 10000 and H9 series) with an adjustment range from 28" - 29" in depth.
Factory Express Portfolio
Factory Express Portfolio
Factory Express Portfolio
Factory Express Portfolio
for Servers and Storage
for Servers and Storage
for Servers and Storage
for Servers and Storage
HP Factory Express offers configuration, customization, integration and deployment services for HP
servers and storage products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex
configuration and design services as well as individual factory services, such as image loading, asset
tagging, and custom packaging. HP products supported through Factory Express include a wide array of
servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000
servers as well as the MSA1000, VA7xxx, EVA3000 & EVA5000, XP, rackable tape libraries and
configurable network switches.
For more information on Factory Express services for your specific server model, please contact your
sales representative or go to http://www.hp.com/go/factory-express.
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Standard Features
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 9
Service and Support
Service and Support
Service and Support
Service and Support
Three-year limited warranty, including hardware diagnostic support, pre-failure warranty (coverage of
hard drives, memory and processors). The warranty is fully supported by HP Services and a worldwide
network of resellers and service providers. In addition 90-days getting started software telephone support
may be covered under the warranty or available for an additional fee. Enhancements to warranty
services are available through HP Care Pack services.
NOTE:
NOTE:
NOTE:
NOTE: Limited warranty includes 3 year parts, 3 year labor, 3-year next business day on-site support.
Care Pack services provide a range of life cycle support options that let you choose the service levels that
meet your business requirements, from basic to mission-critical. A full range of HP Care Pack hardware
and software services are available including:
Installation and start up
Education courses
Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7
days call window with options including 4-hour response or 6-hour Call To Repair
Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and
VMWare-based IT solutions helping to deliver high level of application availability. Response times range
from 30 minutes for critical problems to 2 hours.
System Management, Performance Services and Mission Critical Support Solution.
HP Care Pack services include coverage for the HP branded hardware options qualified for the server,
purchased at the same time or afterward, internal to the enclosure, as well as 22" and smaller external
monitors and tower UPS options up to 3kVA; these items will be covered at the same service level and
for the same coverage period as the server. Coverage of UPS Battery is not included, standard warranty
terms & conditions apply. For servers or storage systems installed within a rack, service also covers all HP
qualified rack options installed within the same rack.
NOTE:
NOTE:
NOTE:
NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or
resellers or visit our worldwide Web site on the internet at: http://www.hp.com/hps/carepack.
NOTE:
NOTE:
NOTE:
NOTE: For more complete information on HP Services offerings, customers and resellers, please visit us
at: http://www.hp.com/hps.
NOTE:
NOTE:
NOTE:
NOTE: Additional information regarding worldwide limited warranty and technical support is available
at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html.
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Standard Features
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 10
Designed for enterprise customers with growing data centers and application and Internet service
providers that require a rack optimized 4-processor server that delivers maximum performance and high
availability for highly complex, business critical applications. Specifically, the HP ProLiant DL585 would
be excellent for running the following types of applications:
Typical Usage
Typical Usage
Typical Usage
Typical Usage:
High Performance Computing (HPC)
Electronic Design Automation (EDA)/semiconductor
Financial
Large database applications
ERP / CRM
Petrochemical
Life Science and Material Science
Video Rendering
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Solutions
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 11
DL585R01 O2.6 GHz-
DL585R01 O2.6 GHz-
DL585R01 O2.6 GHz-
DL585R01 O2.6 GHz-
1MB, 4096MB (2P)
1MB, 4096MB (2P)
1MB, 4096MB (2P)
1MB, 4096MB (2P)
380125-xx1
Processor(s)
Processor(s)
Processor(s)
Processor(s)
(2) AMD 852 Opteron Processors at 2.6 GHz standard (2 or 4 supported)
Cache Memory
Cache Memory
Cache Memory
Cache Memory
1-MB Integrated Level 2 Cache
Memory
Memory
Memory
Memory
4 GB of PC3200 DDR SDRAM (Standard) to 32 GB running at 400MHz with
Advanced ECC
Network Controller
Network Controller
Network Controller
Network Controller
Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network
adapter
Storage Controller
Storage Controller
Storage Controller
Storage Controller
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed
Write Cache Enabler (integrated on system board)
Manageability
Manageability
Manageability
Manageability
Integrated Lights-Out (iLO) Standard management (integrated on system
board)
Hard Drives
Hard Drives
Hard Drives
Hard Drives
None ship standard
Internal Storage
Internal Storage
Internal Storage
Internal Storage
1.20 TB maximum (with optional hard drives)
Power Supply
Power Supply
Power Supply
Power Supply
Two 870W Hot Plug Redundant Power Supplies (low line or high line)
Optical Drive
Optical Drive
Optical Drive
Optical Drive
24x IDE Universal Media Bay CD-ROM Drive
Form Factor
Form Factor
Form Factor
Form Factor
Rack 4U
DL585R01 O2.6 GHz-
DL585R01 O2.6 GHz-
DL585R01 O2.6 GHz-
DL585R01 O2.6 GHz-
1MB, 2048MB (2P)
1MB, 2048MB (2P)
1MB, 2048MB (2P)
1MB, 2048MB (2P)
380124-xx1
Processor(s)
Processor(s)
Processor(s)
Processor(s)
(2) AMD 852 Opteron Processors at 2.6 GHz standard (2 or 4 supported)
Cache Memory
Cache Memory
Cache Memory
Cache Memory
1-MB Integrated Level 2 Cache
Memory
Memory
Memory
Memory
2 GB of PC2700 DDR SDRAM (Standard) to 48 GB running at 333MHz or
64GB running at 266MHz with Advanced ECC
Network Controller
Network Controller
Network Controller
Network Controller
Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network
adapter
Storage Controller
Storage Controller
Storage Controller
Storage Controller
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed
Write Cache Enabler (integrated on system board)
Manageability
Manageability
Manageability
Manageability
Integrated Lights-Out (iLO) Standard management (integrated on system
board)
Hard Drives
Hard Drives
Hard Drives
Hard Drives
None ship standard
Internal Storage
Internal Storage
Internal Storage
Internal Storage
1.20 TB maximum (with optional hard drives)
Power Supply
Power Supply
Power Supply
Power Supply
Two 870W Hot Plug Redundant Power Supplies (low line or high line)
Optical Drive
Optical Drive
Optical Drive
Optical Drive
24x IDE Universal Media Bay CD-ROM Drive
Form Factor
Form Factor
Form Factor
Form Factor
Rack 4U
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Models
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 12
DL585R01 O2.4 GHz-
DL585R01 O2.4 GHz-
DL585R01 O2.4 GHz-
DL585R01 O2.4 GHz-
1MB, 2048MB (2P)
1MB, 2048MB (2P)
1MB, 2048MB (2P)
1MB, 2048MB (2P)
378020-xx1
Processor(s)
Processor(s)
Processor(s)
Processor(s)
(2) AMD 850 Opteron Processors at 2.4 GHz standard (2 or 4 supported)
Cache Memory
Cache Memory
Cache Memory
Cache Memory
1-MB Integrated Level 2 Cache
Memory
Memory
Memory
Memory
2 GB of PC2700 DDR SDRAM (Standard) to 48 GB running at 333MHz or
64GB running at 266MHz with Advanced ECC
Network Controller
Network Controller
Network Controller
Network Controller
Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network
adapter
Storage Controller
Storage Controller
Storage Controller
Storage Controller
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed
Write Cache Enabler (integrated on system board)
Manageability
Manageability
Manageability
Manageability
Integrated Lights-Out (iLO) Standard management (integrated on system
board)
Hard Drives
Hard Drives
Hard Drives
Hard Drives
None ship standard
Internal Storage
Internal Storage
Internal Storage
Internal Storage
1.20 TB maximum (with optional hard drives)
Power Supply
Power Supply
Power Supply
Power Supply
Two 870W Hot Plug Redundant Power Supplies (low line or high line)
Optical Drive
Optical Drive
Optical Drive
Optical Drive
24x IDE Universal Media Bay CD-ROM Drive
Form Factor
Form Factor
Form Factor
Form Factor
Rack 4U
DL585R01 O2.2 GHz-
DL585R01 O2.2 GHz-
DL585R01 O2.2 GHz-
DL585R01 O2.2 GHz-
1MB, 2048MB (2P)
1MB, 2048MB (2P)
1MB, 2048MB (2P)
1MB, 2048MB (2P)
356820-xx1
Processor(s)
Processor(s)
Processor(s)
Processor(s)
(2) AMD 848 Opteron Processors at 2.2 GHz standard (2 or 4 supported)
Cache Memory
Cache Memory
Cache Memory
Cache Memory
1-MB Integrated Level 2 Cache
Memory
Memory
Memory
Memory
2 GB of PC2100 DDR SDRAM running at 266MHz (Standard) to 64 GB
(Maximum) with Advanced ECC
Network Controller
Network Controller
Network Controller
Network Controller
Embedded NC7782 Dual Port PCI-X 10/100/1000T Gigabit network
adapter
Storage Controller
Storage Controller
Storage Controller
Storage Controller
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed
Write Cache Enabler (integrated on system board)
Manageability
Manageability
Manageability
Manageability
Integrated Lights-Out (iLO) Standard management (integrated on system
board)
Hard Drives
Hard Drives
Hard Drives
Hard Drives
None ship standard
Internal Storage
Internal Storage
Internal Storage
Internal Storage
1.20 TB maximum (with optional hard drives)
Power Supply
Power Supply
Power Supply
Power Supply
Two 870W Hot Plug Redundant Power Supplies (low line or high line)
Optical Drive
Optical Drive
Optical Drive
Optical Drive
24x IDE Universal Media Bay CD-ROM Drive
Form Factor
Form Factor
Form Factor
Form Factor
Rack 4U
Country Code Key
Country Code Key
Country Code Key
Country Code Key
XX=00
US (NOTE:
NOTE:
NOTE:
NOTE: Valid for 2.4 GHz, 2.6 Models)
XX=20
Brazil (NOTE:
NOTE:
NOTE:
NOTE: Valid for 2.2 GHz, 2.4 GHz, and 2.6 Models only)
XX=29
Japan
XX=37
A/P (NOTE:
NOTE:
NOTE:
NOTE: Valid for 2.4 GHz and 2.6 Models only)
XX=42
Europe (NOTE:
NOTE:
NOTE:
NOTE: Valid for 2.4 GHz and 2.6 Models only)
XX=AA
PRC
XX=B2
WW (NOTE:
NOTE:
NOTE:
NOTE: Valid for 1.8 GHz, and 2.2 GHz Models only)
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Models
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 13
NOTE: HP does not allow factory integration of options into standard models listed above.
Configure-to-order servers must start with a CTO Chassis.
NOTE:
NOTE:
NOTE:
NOTE: This product offering does not support HP Factory Express Server Configuration Level 1.
Step 1: Base Configuration
Step 1: Base Configuration
Step 1: Base Configuration
Step 1: Base Configuration
Models
Models
Models
Models
HP ProLiant DL585 Rack CTO Chassis (North America)
390524-405
Factory Integrated Models ship with:
Factory Integrated Models ship with:
Factory Integrated Models ship with:
Factory Integrated Models ship with:
1.44MB Diskette Drive
Dual Port NC7782 embedded NIC
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed Write
Cache Enabler (integrated on system board)
Integrated Lights-Out (iLO) Standard management (integrated on system board)
Two 870W Hot Plug Redundant Power Supplies (low line or high line)
Rack 4U Form Factor
HP ProLiant DL585 Rack CTO Chassis (ROW)
390524-B21
Factory Integrated Models ship with:
Factory Integrated Models ship with:
Factory Integrated Models ship with:
Factory Integrated Models ship with:
1.44MB Diskette Drive
Dual Port NC7782 embedded NIC
Smart Array 5i Plus Controller (Dual Channel, Ultra3) with Battery-Backed Write
Cache Enabler (integrated on system board)
Integrated Lights-Out (iLO) Standard management (integrated on system board)
Two 870W Hot Plug Redundant Power Supplies (low line or high line)
Rack 4U Form Factor
Step 2: Choose Required Options (only one of the following from each list unless otherwise
Step 2: Choose Required Options (only one of the following from each list unless otherwise
Step 2: Choose Required Options (only one of the following from each list unless otherwise
Step 2: Choose Required Options (only one of the following from each list unless otherwise
noted)
noted)
noted)
noted)
Processors
Processors
Processors
Processors
AMD O852 2.6GHz/1000 1MB PC3200 DL585 FIO BASE
NOTE:
NOTE:
NOTE:
NOTE: If four processors are desired, select one 385751-L21 and two 381477-B21.
385751-L21
AMD O852 2.6GHz/1000 1MB PC2700 DL585 FIO BASE
NOTE:
NOTE:
NOTE:
NOTE: If four processor are required, select one 385750-L21 and two 381476-B21.
385750-L21
AMD O850 2.4GHz/800 1MB DL585 FIO BASE
NOTE:
NOTE:
NOTE:
NOTE: If four processors are desired, select one 381078-L21 and two 366725-B21.
381078-L21
AMD O848 2.2GHz/800 1MB DL585 FIO BASE
NOTE:
NOTE:
NOTE:
NOTE: If four processors are desired, select one 381077-L21 and two 359708-B21.
381077-L21
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Configuration Information - Factory Integrated Models
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 14
1GB of PC2700 DDR SDRAM DIMM Memory (2x512 MB)
371047-B21
2GB of PC2700 DDR SDRAM DIMM Memory (2x1 GB)
371048-B21
4GB of PC2700 DDR SDRAM DIMM Memory (2x2 GB)
371049-B21
2GB of PC3200 DDR SDRAM DIMM Memory (2x1 GB)
376639-B21
4GB of PC3200 DDR SDRAM DIMM Memory (2x2 GB)
379300-B21
NOTE:
NOTE:
NOTE:
NOTE: Memory must be ordered in like-pairs, i.e. two of the same size.
NOTE:
NOTE:
NOTE:
NOTE: For max memory performance with PC2700 (333MHz), -002 processor
boards should be used in conjunction with no more than 6 PC2700 DIMMs per
processor. -002 board ships standard with 2.4GHZ SKUs and faster SKUs.
Optical Drives
Optical Drives
Optical Drives
Optical Drives
24x IDE Universal Media Bay CD-ROM Drive
339866-B21
Slimline CD-RW/DVD-ROM 24X Combo Drive Option Kit
331903-B21
Slimline DVD-ROM Drive (8X/24X) Option Kit (Servers)
264007-B21
HP DVD+R/RW 8X Slim
383975-B21
Step 3: Choose Additional Options for Factory Integration
Step 3: Choose Additional Options for Factory Integration
Step 3: Choose Additional Options for Factory Integration
Step 3: Choose Additional Options for Factory Integration
NOTE:
NOTE:
NOTE:
NOTE: Select from "Options" section below.
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Configuration Information - Factory Integrated Models
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 15
NOTE: Some options may not be factory integratable. Please contact your local sales representative for
additional information.
ProLiant DL585 Unique
ProLiant DL585 Unique
ProLiant DL585 Unique
ProLiant DL585 Unique
Options
Options
Options
Options
AMD Opteron 852 2.6 GHz-1MB PC3200 Processor Option Kit for the ProLiant
DL585
NOTE:
NOTE:
NOTE:
NOTE: This Opteron 852 2.6GHz PC3200 processor Option kit (PN 381477-B21)
comes standard with the 012567-001 processor/memory board.
381477-B21
AMD Opteron 852 2.6 GHz-1MB PC2700 Processor Option Kit for the ProLiant
DL585
NOTE:
NOTE:
NOTE:
NOTE: This Opteron 852 2.6GHz PC2700 processor Option kit (PN 381476-B21)
comes standard with the -003 processor/memory board.
381476-B21
AMD Opteron 850 2.4 GHz-1MB Processor Option Kit for the ProLiant DL585
NOTE:
NOTE:
NOTE:
NOTE: This Opteron 850 2.4GHz processor Option kit (PN 366725-B21) comes
standard with the -002 processor/memory board.
366725-B21
AMD Opteron 848 2.2 GHz-1MB Processor Option Kit for the ProLiant DL585
NOTE:
NOTE:
NOTE:
NOTE: This Opteron 848 2.2GHz processor Option kit (PN 359708-B21) comes
standard with the processor/memory board.
359708-B21
AMD Opteron 844 1.8 GHz-1MB Processor Option Kit for the ProLiant DL585
NOTE:
NOTE:
NOTE:
NOTE: This Opteron 844 1.8GHz processor Option kit (PN 359707-B21) comes
standard with the processor/memory board.
359707-B21
AMD Opteron 842 1.6 GHz-1MB Processor Option Kit for the ProLiant DL585
NOTE:
NOTE:
NOTE:
NOTE: This Opteron 842 1.6GHz processor Option kit (PN 359706-B21) comes
standard with the processor/memory board.
359706-B21
NOTE:
NOTE:
NOTE:
NOTE: Must order two kits to expand the system from 2 to 4 processors
ProLiant Essentials
ProLiant Essentials
ProLiant Essentials
ProLiant Essentials
Value Pack Software
Value Pack Software
Value Pack Software
Value Pack Software
Rapid Deployment Pack, 1 User, V1.x
NOTE:
NOTE:
NOTE:
NOTE: This license allows 1 server to be managed and deployed via the Deployment
Server.
267196-B21
Rapid Deployment Pack, 1 User, V1.x (Japan)
NOTE:
NOTE:
NOTE:
NOTE: This license allows 1 server to be managed and deployed via the Deployment
Server.
267196-291
Rapid Deployment Pack, 10 Users, V1.x
NOTE:
NOTE:
NOTE:
NOTE: This license allows 10 servers to be managed and deployed via the
Deployment Server.
269817-B21
Rapid Deployment Pack, 10 Users, V1.x (Japan)
NOTE:
NOTE:
NOTE:
NOTE: This license allows 10 servers to be managed and deployed via the
Deployment Server.
269817-291
Flexible Quantity License Kit
302127-B21
License-Only - for use with a Master License Agreement
302128-B21
ProLiant Essentials Workload Management Pack (Featuring Resource Partitioning
Manager version 2.0)
303284-B21
ProLiant Essentials Performance Management Pack v2.0, Single License
NOTE:
NOTE:
NOTE:
NOTE: This license allows 1 server to be managed by Performance Management
Pack.
306696-B21
ProLiant Essentials Performance Management Pack, 10 Pack Server License
374055-B21
Performance Management Pack, flexible license kit
NOTE:
NOTE:
NOTE:
NOTE: A single pack is shipped with a single license key for the total number of
licenses ordered.
306697-B21
ProLiant Essentials Intelligent Networking Pack, 1 License
372906-B21
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 16
ProLiant Essentials Intelligent Networking Pack Flex License
372950-B21
ProLiant Essentials Intelligent Networking Pack Track License
372951-B21
ProLiant Essentials Virtual Machine Management Pack, SINGLE LIC IP CCAO-WGR
372214-B21
ProLiant Essentials Virtual Machine Management Pack, FLEX LIC IP CCAO-WGR
372215-B21
ProLiant Essentials Virtual Machine Management Pack, TRACKING LIC IP CCAO-
WGR
372216-B21
ProLiant Essentials Vulnerability and Patch Management Pack, Single-Server License
371645-B21
ProLiant Essentials Vulnerability and Patch Management Pack, 10-Server License
372029-B21
ProLiant Essentials Vulnerability and Patch Management Pack, Flexible-Quantity
License
371646-B21
ProLiant Essentials Vulnerability and Patch Management Pack, Tracking license for
new servers
371647-B21
ProLiant Essentials Vulnerability and Patch Management Pack, Tracking license for
installed servers
378372-B21
ProLiant Essentials Server Migration Pack, Single-Server License
375345-B21
ProLiant Essentials Server Migration Pack, Flexible-Quantity License
375346-B21
ProLiant Essentials Server Migration Pack, Tracking license
375347-B21
ProLiant Essentials Vulnerability and Patch Management Pack, 1-Server 10-Desktop
Bundle License
389941-B21
NOTE:
NOTE:
NOTE:
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various
ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE:
NOTE:
NOTE:
NOTE: For more information regarding ProLiant Essentials Software, please see the
following URL: http://www.hp.com/servers/proliantessentials.
Software
Software
Software
Software
HP digital asset protection
302316-001
Processor
Processor
Processor
Processor
AMD Opteron 852 2.6 GHz-1MB PC3200 Processor Option Kit
381477-B21
AMD Opteron 852 2.6 GHz-1MB PC2700 Processor Option Kit
NOTE:
NOTE:
NOTE:
NOTE: Two 870W Hot Plug Redundant Power Supplies (low line or high line) are
required if power redundancy is desired with 2.6GHz processors.
381476-B21
AMD Opteron 850 2.4 GHz-1MB Processor Option Kit
366725-B21
AMD Opteron 848 2.2 GHz-1MB Processor Option Kit
359708-B21
AMD Opteron 844 1.8 GHz-1MB Processor Option Kit
359707-B21
AMD Opteron 842 1.6 GHz-1MB Processor Option Kit
359706-B21
NOTE:
NOTE:
NOTE:
NOTE: Must order two kits to expand the system from 2 to 4 processors
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 17
1GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 512 MB)
300679-B21
2GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 1 GB)
300680-B21
4GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 2 GB)
300682-B21
1GB of PC2700 DDR SDRAM DIMM Memory (2 x 512 MB)
371047-B21
2GB of PC2700 DDR SDRAM DIMM Memory (2 x 1 GB)
371048-B21
4GB of PC2700 DDR SDRAM DIMM Memory (2 x 2 GB)
371049-B21
2GB of PC3200 DDR SDRAM DIMM Memory (2 x 1 GB)
376639-B21
4GB of PC3200 DDR SDRAM DIMM Memory (2 x 2 GB)
379300-B21
NOTE:
NOTE:
NOTE:
NOTE: The PC2700 DDR SDRAM DIMM Memory Kits are supported by the 2.4 GHz
and faster models only.
NOTE:
NOTE:
NOTE:
NOTE: For max memory PC2700 performance (333MHz), -002 processor boards
must be used in conjunction with no more than 6 PC2700 DIMMs per processor.
Optical Drives
Optical Drives
Optical Drives
Optical Drives
Slimline CD-RW/DVD-ROM 24X Combo Drive Option Kit (Servers)
331903-B21
Slimline DVD-ROM Drive (8X/24X) Option Kit (Servers)
264007-B21
HP DVD+R/RW 8X Slim
383975-B21
Hard Drives
Hard Drives
Hard Drives
Hard Drives
Ultra320 SCSI – Universal Hot Plug
Ultra320 SCSI – Universal Hot Plug
Ultra320 SCSI – Universal Hot Plug
Ultra320 SCSI – Universal Hot Plug
300-GB 10,000 rpm U320 Universal Hard Drive (1")
350964-B22
146.8-GB 10,000 rpm U320 Universal Hard Drive (1")
286716-B22
72.8-GB 10,000 rpm U320 Universal Hard Drive (1")
286714-B22
146.8-GB 15,000 rpm U320 Universal Hard Drive (1")
347708-B22
72.8-GB 15,000 rpm U320 Universal Hard Drive (1")
286778-B22
36.4-GB 15,000 rpm U320 Universal Hard Drive (1")
286776-B22
NOTE:
NOTE:
NOTE:
NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3
speeds. U320 drives require an optional U320 Smart Array Controller or U320 SCSI
HBA to support U320 transfer rates.
NOTE:
NOTE:
NOTE:
NOTE: Please see the Hard Drive QuickSpecs for Technical Specifications such as
capacity, height, width, interface, transfer rate, seek time, physical configuration, and
operating temperature:
U320 Hard Drive QS:
http://h18000.www1.hp.com/products/quickspecs/11531_div/11531_div.HTML
(Worldwide)
http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.HTML
(North America)
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 18
Smart Array 6402/128 Controller
273915-B21
Smart Array 6404/256 Controller
273914-B21
Smart Array 641 Controller
291966-B21
Smart Array 642 Controller
NOTE:
NOTE:
NOTE:
NOTE: The Smart Array 641 and 642 Controller must be placed in the 100MHz slots
only.
291967-B21
256MB DDR, Battery-Backed Cache Upgrade Kit for SA-6400
NOTE:
NOTE:
NOTE:
NOTE: This 256-MB Battery-Backed Cache Module upgrade kit supports the Smart
Array 6400 series controller only.
273913-B21
64 MB Battery Backed Write Cache Enabler
NOTE
NOTE
NOTE
NOTE: This 64 MB BBWC supports the Smart Array 641 Controller and Smart Array
642 Controller.
291969-B21
128MB Battery-Backed Cache Enabler
NOTE:
NOTE:
NOTE:
NOTE: This 128MB BBWC supports the Smart Array 641 Controller and Smart Array
642 Controller.
351580-B21
DL585 Cable Assembly, SCSI, Ultra3, LVDS
NOTE:
NOTE:
NOTE:
NOTE: All DL585 models ship standard with the integrated Smart Array 5i Plus
Controller, which has been designed to deliver maximum performance and availability
across the internal SCSI Duplex backplane.
365483-B21
The Ultra3 SCSI cable is required only if the customer chooses to bypass the
Smart Array 5i Plus Controller and connect slot-based SCSI adapters or RAID
controllers to the internal SCSI Duplex backplane.
Two cables are required to maintain the standard, duplexed configuration of
the backplane.
One cable is required if the simplex configuration is chosen.
The backplane is easily configured to simplex mode by means of a simple switch
duplex to simplex) located on the top of the backplane itself.
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
268351-B21
Ultra320 Expansion Module for SA-6402
273911-B21
NOTE:
NOTE:
NOTE:
NOTE: Please see the following Controller or SCSI Adapter QuickSpecs for Technical
Specifications such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols
supported, SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported,
Cache, RAID support, and additional information:
http://h18000.www1.hp.com/products/quickspecs/11587_div/11587_div.HTML
(Smart Array 6400 Series)
http://h18000.www1.hp.com/products/quickspecs/12067_div/12067_div.HTML
(Smart Array 641)
http://h18000.www1.hp.com/products/quickspecs/12069_div/12069_div.HTML
(Smart Array 642)
http://h18000.www1.hp.com/products/quickspecs/10429_div/10429_div.HTML
(SCSI Adapter)
http://h18000.www1.hp.com/products/quickspecs/11555_div/11555_div.HTML
(U320 Adapter)
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 19
HP NC150T PCI 4-port Gigabit 1000T Combo Switch Adapter
367132-B21
HP NC310F PCI-X 1000SX Gigabit Server Adapter
368169-B21
HP NC1020 PCI 1000T Gigabit Server Adapter
353377-B21
HP NC6170 PCI-X Dual Port 1000SX Gigabit Server Adapter
313879-B21
HP NC7170 PCI-X Dual Port 1000T Gigabit Server Adapter
313881-B21
HP NC7771 PCI-X 1000T Gigabit Server Adapter
290563-B21
HP NC570C PCI-X Dual-port 4x Fabric Adapter
376160-B21
HP 24-Port 4x Fabric Copper Switch
376227-B21
HP 4x Fabric 1m Copper Cable
376232-B21
HP 4x Fabric 3m Copper Cable
376232-B22
HP 4x Fabric 5m Copper Cable
376232-B23
Management
Management
Management
Management
Integrated Lights-Out (iLO) Advanced Pack
263825-B21
Security
Security
Security
Security
HP/Atalla AXL600L SSL Accelerator Card for ProLiant Servers
524545-B21
AXL300 Accelerator PCI Card for ProLiant Servers
227933-B21
Monitors
Monitors
Monitors
Monitors
Rack-mount Flat Panel Monitors
Rack-mount Flat Panel Monitors
Rack-mount Flat Panel Monitors
Rack-mount Flat Panel Monitors
TFT5110R Flat Panel Monitor (Carbon)
281683-B21
TFT7210R Rack Mounted 17" Monitor
348373-B21
NOTE:
NOTE:
NOTE:
NOTE: Monitors larger than 17'' may be too heavy for use in rack systems.
NOTE:
NOTE:
NOTE:
NOTE: For a complete list of Rack Monitors please view the following URL:
http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/
NOTE:
NOTE:
NOTE:
NOTE: For a complete list of Monitors please view one of the following URL:
http://h18004.www1.hp.com/products/monitors/.
Tape Drives
Tape Drives
Tape Drives
Tape Drives
NOTE:
NOTE:
NOTE:
NOTE: For complete listing of tape drive offerings see
http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
For recommended tape drive offerings for this ProLiant server see the following:
NOTE:
NOTE:
NOTE:
NOTE: Use of a SCSI adapter to connect these devices is required.
Ultrium Tape Drives - External, Rack-Mount and Array
Ultrium Tape Drives - External, Rack-Mount and Array
Ultrium Tape Drives - External, Rack-Mount and Array
Ultrium Tape Drives - External, Rack-Mount and Array
HP StorageWorks Ultrium 215 Tape Drive, External (Carbon)
Q1545A
HP StorageWorks Ultrium 215 rack-mount (Carbon) - Single drive installed in a 1U
rack-mount kit
A7444A
HP StorageWorks Ultrium 448 Tape Drive, External (Carbonite)
DW017A
HP StorageWorks Ultrium 448, Rack-mount (Carbonite) - Single drive installed in a
1U rack-mount kit
DW028A
HP StorageWorks Ultrium 460 Tape Drive, External (Carbon)
Q1520A
HP StorageWorks Ultrium 460, Rack-mount (Carbon) - Single drive installed in a 3U
rack-mount kit
350546-B21
HP StorageWorks Ultrium 960 Tape Drive, External (Carbonite)
Q1539A
HP StorageWorks Ultrium 960 Rack-mount (Carbonite) - Single drive installed in a 3U
rack-mount kit
Q1595A
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 20
NOTE: Please see the HP StorageWorks Ultrium Tape Drive QuickSpecs for
additional options such as controllers, media, and other related items:
http://h18006.www1.hp.com/products/quickspecs/11739_div/11739_div.html
(Worldwide)
http://h18006.www1.hp.com/products/quickspecs/11739_na/11739_na.html
(North America)
http://h18006.www1.hp.com/products/quickspecs/12128_div/12128_div.html
(Worldwide)
http://h18006.www1.hp.com/products/quickspecs/12128_na/12128_na.html
(North America)
For an up-to-date listing of the latest O/S and software support details for HP Ultrium
tape drives, please visit: http://www.hp.com/go/connect
DAT Drives - External, Rack-Mount and Array Module
DAT Drives - External, Rack-Mount and Array Module
DAT Drives - External, Rack-Mount and Array Module
DAT Drives - External, Rack-Mount and Array Module
HP StorageWorks 1U Rack-Mount Kit with one DAT 72 drive (Carbon)
A7443A
HP StorageWorks DAT 72 Tape Drive, External (Carbon)
Q1523A
HP StorageWorks DAT 40 Tape Drive, External (Carbon)
C5687C
HP StorageWorks DAT 24 Tape Drive, External (Flint)
C1556D
NOTE:
NOTE:
NOTE:
NOTE: Please see the DAT Tape Drive QuickSpecs for controllers, media, and other
options:
http://h18000.www1.hp.com/products/quickspecs/11883_div/11883_div.HTML
(Worldwide)
http://h18000.www1.hp.com/products/quickspecs/11883_na/11883_na.HTML
(North America)
For an up-to-date listing of the latest O/S and software support details for HP DAT
drives, please visit: http://www.hp.com/go/connect
Rack-Mount Tape Drive Enclosures
Rack-Mount Tape Drive Enclosures
Rack-Mount Tape Drive Enclosures
Rack-Mount Tape Drive Enclosures
HP StorageWorks 1U Rack-Mount Kit
NOTE:
NOTE:
NOTE:
NOTE: The 1U Rack-mount Kit can support up to 2 half-height tape drives and
compatible with multiple Single-Ended and LVD SCSI tape drives including DAT 24,
DAT40, DAT72, DLT VS 80, Ultrium 215 and Ultrium 448 tape drives.
A7445A
HP StorageWorks 3U Rack-Mount Kit
NOTE:
NOTE:
NOTE:
NOTE: The 3U Rack-Mount Kit can support up to 2 full-height or 4 half-height tape
drives and compatible with multiple Single-Ended and LVD SCSI tape drives including
DAT 24, DAT 40, DAT 72, , DLT VS80, SDLT 320, Ultrium 215, Ultrium 230, Ultrium
448, Ultrium 460, and Ultrium 960 Tape Drives.
274338-B21
HP StorageWorks 5U Rack-Mount Kit
NOTE:
NOTE:
NOTE:
NOTE: The 5U Rack-Mount Kit can support up to 4 full-height tape drives and is
compatible with SDLT 320, Ultrium 230, Ultrium 460, and Ultrium 960 tape drives.
274339-B21
NOTE:
NOTE:
NOTE:
NOTE: Please see the Rack-Mount Tape Drive Kits QuickSpecs for additional
information regarding these kits:
http://h18000.www1.hp.com/products/quickspecs/10854_div/10854_div.HTML
(Worldwide)
http://h18000.www1.hp.com/products/quickspecs/10854_na/10854_na.HTML
(North America)
Accessories for 3U & 5U Rack-mount Tape Drive Kits
Accessories for 3U & 5U Rack-mount Tape Drive Kits
Accessories for 3U & 5U Rack-mount Tape Drive Kits
Accessories for 3U & 5U Rack-mount Tape Drive Kits
LVD Cable Kit, VHDCI/HD68
NOTE:
NOTE:
NOTE:
NOTE: For use with the 3U Rack-mount Kit and 5U Rack-mount Kit only.
168048-B21
LVD Cable Kit, HD68/HD68
NOTE:
NOTE:
NOTE:
NOTE: For use with the 3U Rack-mount Kit and 5U Rack-mount Kit only.
242381-B21
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 21
HP StorageWorks DAT 72x6 Tape Autoloader, External (Flint)
Q1567A
NOTE:
NOTE:
NOTE:
NOTE: Please see the DAT 72x6 Tape Autoloader QuickSpecs for additional options
such as host bus adapters, controllers and media:
http://h18006.www1.hp.com/products/quickspecs/11905_div/11905_div.html
(Worldwide)
http://h18006.www1.hp.com/products/quickspecs/11905_na/11905_na.html
(North America)
HP StorageWorks 1/8 Tape Autoloader
HP StorageWorks 1/8 Tape Autoloader
HP StorageWorks 1/8 Tape Autoloader
HP StorageWorks 1/8 Tape Autoloader
1/8 Ultrium 460 Tape Autoloader, Tabletop
AA927A
1/8 SDLT 320 Tape Autoloader, Tabletop
AA926A
1/8 Ultrium 230 Tape Autoloader, Tabletop
C9572CB
1/8 DLT VS80 Tape Autoloader, Tabletop
C9264CB
1/8 Tape Autoloader Rackmount Kit
C9268R
NOTE:
NOTE:
NOTE:
NOTE: Required to install the 1/8 tape autoloader in a standard 19-inch rack
NOTE:
NOTE:
NOTE:
NOTE: Please reference the 1/8 Tape Autoloader QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
http://www.hp.com/go/ebs
HP StorageWorks SSL1016 Tape Autoloader
HP StorageWorks SSL1016 Tape Autoloader
HP StorageWorks SSL1016 Tape Autoloader
HP StorageWorks SSL1016 Tape Autoloader
SSL1016 Ultrium 460 Tape Autoloader
330821-B21
SSL1016 SDLT 320 Tape Autoloader
330816-B21
NOTE:
NOTE:
NOTE:
NOTE: Please reference the SSL1016 Tape Autoloader QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
http://www.hp.com/go/ebs.
Tape Libraries
Tape Libraries
Tape Libraries
Tape Libraries
HP StorageWorks MSL6000 Tape Library
HP StorageWorks MSL6000 Tape Library
HP StorageWorks MSL6000 Tape Library
HP StorageWorks MSL6000 Tape Library
Ultrium 960 technology
Ultrium 960 technology
Ultrium 960 technology
Ultrium 960 technology
MSL6030, 1 drive, 30 slots, Ultrium 960
AD606A
MSL6030, 2 drive, 30 slots, Ultrium 960
AD607A
MSL6030, 1 drive, 30 slots, Ultrium 960, with embedded FC router
AD608A
MSL6030, 2 drive, 30 slots, Ultrium 960, with embedded FC router
AD609A
MSL6060, 2 drive, 60 slots, Ultrium 960
AD610A
MSL6060, 2 drive, 60 slots, Ultrium 960, with embedded FC router
AD611A
SDLT 600 technology
SDLT 600 technology
SDLT 600 technology
SDLT 600 technology
MSL6026, 1 drive, 26 slots, SDLT 600
AD582A
MSL6026, 2 drive, 26 slots, SDLT 600
AD583A
MSL6026, 1 drive, 26 slots, SDLT 600, with embedded FC router
AD584A
MSL6026, 2 drive, 26 slots, SDLT 600, with embedded FC router
AD585A
MSL6052, 2 drive, 52 slots, SDLT 600
AD587A
MSL6052, 2 drive, 52 slots, SDLT 600, with embedded FC router
AD588A
Ultrium 460 technology
Ultrium 460 technology
Ultrium 460 technology
Ultrium 460 technology
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 22
MSL6030, 1 drive, 30 slots, Ultrium 460
AD598A
MSL6030, 2 drive, 30 slots, Ultrium 460
AD599A
MSL6030, 1 drive, 30 slots, Ultrium 460, with embedded FC router
AD600A
MSL6030, 2 drive, 30 slots, Ultrium 460, with embedded FC router
AD601A
MSL6060, 2 drive, 60 slot Ultrium 460
AD603A
MSL6060, 2 drive, 60 slot Ultrium 460, with embedded FC router
AD604A
NOTE:
NOTE:
NOTE:
NOTE: Please reference the MSL6000 Tape Library QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
http://www.hp.com/go/ebs.
HP StorageWorks MSL5026S2 Tape Library
HP StorageWorks MSL5026S2 Tape Library
HP StorageWorks MSL5026S2 Tape Library
HP StorageWorks MSL5026S2 Tape Library
MSL5026S2, 1 DRV, SDLT320, RM Library
293472-B22
MSL5026S2, 2 DRV, SDLT320, RM Library
293472-B23
MSL5026S2, 1 DRV, SDLT320, Fibre Channel, RM Library
293472-B24
MSL5026S2, 2 DRV, SDLT320, Fibre Channel, RM Library
293472-B25
NOTE:
NOTE:
NOTE:
NOTE: Please reference the MSL5026S2 Tape Library QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
http://www.hp.com/go/ebs
HP
HP
HP
HP StorageWorks MSL5052S2 Tape Library
StorageWorks MSL5052S2 Tape Library
StorageWorks MSL5052S2 Tape Library
StorageWorks MSL5052S2 Tape Library
MSL5052S2, 2 DRV, SDLT320, RM Library
293474-B21
MSL5052S2, 2 DRV, SDLT320, Fibre Channel, RM Library
293474-B24
NOTE:
NOTE:
NOTE:
NOTE: Please reference the MSL5052S2 Tape Library QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
http://www.hp.com/go/ebs
HP StorageWorks MSL5060 Tape Library
HP StorageWorks MSL5060 Tape Library
HP StorageWorks MSL5060 Tape Library
HP StorageWorks MSL5060 Tape Library
MSL5060, 2 DRV, Ultrium 230, RM Library
301899-B22
MSL5060, 2 DRV, Ultrium 230, Fibre Channel, RM Library
301899-B23
NOTE:
NOTE:
NOTE:
NOTE: Please reference the MSL5060 Tape Library QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
http://www.hp.com/go/ebs
HP StorageWorks ESL E-Series Tape Libraries
HP StorageWorks ESL E-Series Tape Libraries
HP StorageWorks ESL E-Series Tape Libraries
HP StorageWorks ESL E-Series Tape Libraries
ESL Extended 712e Tape Library, 0 drive, 712 LTO slots
AA934B
ESL Extended 630e Tape Library, 0 drive, 630 SDLT slots
AA935B
ESL Extended 322e Tape Library, 0 drive, 322 LTO slots
AA939B
ESL Extended 286e Tape Library, 0 drive, 286 SDLT slots
AA940B
ESL E-Series Ultrium 960 drive kit
AD595A
ESL E Ultrium 460 drive kit
AA937A
ESL E-Series Ultrium 460-FC drive kit
AA941A
ESL E SDLT 320 drive kit
AA936A
ESL E-Series e2400-FC 2G Interface Controller
AA928A
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 23
NOTE: Please reference the ESL E-Series Tape Libraries QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
http://www.hp.com/go/ebs
Magento-Optical
Magento-Optical
Magento-Optical
Magento-Optical
Jukeboxes
Jukeboxes
Jukeboxes
Jukeboxes
HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes
HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes
HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes
HP StorageWorks 9.1 GB Mid-range Optical Jukeboxes
300mx, 2 drive, 32 slot jukebox
C1150M
600mx, 4 drive, 64 slot jukebox
C1160M
700mx, 2 drive, 76 slot jukebox
C1170M
NOTE:
NOTE:
NOTE:
NOTE: Please reference the Magneto-Optical Jukebox data sheets at
http://www.hp.com/go/optical for additional information needed to create a
complete solution.
HP StorageWorks 9.1 GB High-end Optical Jukeboxes
HP StorageWorks 9.1 GB High-end Optical Jukeboxes
HP StorageWorks 9.1 GB High-end Optical Jukeboxes
HP StorageWorks 9.1 GB High-end Optical Jukeboxes
1200mx, 4 drive, 128 slots
C1104M
1200mx, 6 drive, 128 slots
C1105M
2200mx, 4 drive, 238 slots
C1111M
2200mx, 6 drive, 238 slots
C1107M
2200mx, 10 drive, 238 slots
C1110M
NOTE:
NOTE:
NOTE:
NOTE: Please reference the Magneto-Optical Jukebox data sheets at
http://www.hp.com/go/optical for additional information needed to create a
complete solution.
HP StorageWorks Ultra Density Optical Storage
HP StorageWorks Ultra Density Optical Storage
HP StorageWorks Ultra Density Optical Storage
HP StorageWorks Ultra Density Optical Storage
1000ux, 2 drive, 32 slot jukebox
AA965A
1900ux, 4 drive, 64 slot jukebox
AA966A
1900ux, 4 mixed drive, 64 slot jukebox
AA968A
2300ux, 2 drive, 76 slot jukebox
AA967A
3800ux, 4 drive, 128 slot jukebox
AA969A
3800ux, 6 drive, 128 slot jukebox
AA970A
7100ux, 4 drive, 238 slot jukebox
AA973A
7100ux, 6 drive, 238 slot jukebox
AA971A
7100ux, 10 drive, 238 slot jukebox
AA972A
7100ux, 6 mixed drive, 238 slot jukebox
AA974A
NOTE:
NOTE:
NOTE:
NOTE: Please reference the Magneto-Optical Jukebox data sheets at
http://www.hp.com/go/optical for additional information needed to create a
complete solution.
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 24
ProLiant Cluster Starter Kit
364023-B21
NOTE:
NOTE:
NOTE:
NOTE: For additional information regarding the ProLiant Cluster Starter Kit please see
the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11935_na/11935_na.html
(North America)
http://h18000.www1.hp.com/products/quickspecs/11935_div/11935_div.html
(Worldwide)
ProLiant Cluster Kit with OpenView Storage Mirroring
364025-B21
NOTE:
NOTE:
NOTE:
NOTE: For additional information regarding the ProLiant Cluster Kit with OpenView
Storage Mirroring please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11934_na/11934_na.html
(North America)
http://h18000.www1.hp.com/products/quickspecs/11934_div/11934_div.html
(Worldwide)
ProLiant Cluster HA/F200 for the Entry Level SAN
364026-B21
ProLiant Cluster HA/F200 for the Entry Level SAN (Japan)
364026-291
NOTE:
NOTE:
NOTE:
NOTE: For additional information regarding the ProLiant Cluster for Entry Level SAN
please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11932_na/11932_na.html
(North America)
http://h18000.www1.hp.com/products/quickspecs/11932_div/11932_div.html
(Worldwide)
ProLiant Cluster HA/F500 for the Enterprise SAN
364024-B21
HP Serviceguard for Linux ProLiant Cluster A.11.15 for SUSE SLES 8 / UnitedLinux 1.0
and Red Hat EL 3 (2 node license cluster kit)
305199-B24
HP Serviceguard for Linux ProLiant Cluster A.11.16 for SUSE SLES 9 and Red Hat EL 3
(2 node license cluster kit)
305199-B25
HP Serviceguard for Linux License A.11.15 for SUSE SLES 8 / UnitedLinux 1.0 and
Red Hat EL 3 (single license version)
307754-B24
HP Serviceguard for Linux A.11.16 for SUSE SLES9 and Red Hat EL 3 (single license
version)
307754-B25
NOTE:
NOTE:
NOTE:
NOTE: For additional information regarding HP Serviceguard for Linux, please see
the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11518_na/11518_na.html
(North America)
http://h18000.www1.hp.com/products/quickspecs/11518_div/11518_div.html
(Worldwide)
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 25
External Storage – Rack
External Storage – Rack
External Storage – Rack
External Storage – Rack
HP StorageWorks Modular Smart Array 20
NOTE:
NOTE:
NOTE:
NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity,
redundant power supplies.
335921-B21
HP StorageWorks Modular Smart Array 20 Starter Kit
NOTE:
NOTE:
NOTE:
NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity,
redundant power supplies. Includes Smart Array 6402/128 Controller.
366172-B21
NOTE:
NOTE:
NOTE:
NOTE: The Modular Smart Array Enclosure 20 Family supports the SATA 1.5Gb/s 1"
Hot Plug Hard Drives.
HP StorageWorks Modular Smart Array 30 SB
NOTE:
NOTE:
NOTE:
NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies
302969-B21
HP StorageWorks Modular Smart Array 30 DB
NOTE:
NOTE:
NOTE:
NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies
302970-B21
NOTE:
NOTE:
NOTE:
NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3,
Ultra320 1" Hot Plug Hard Drives.
Redundant Power Supply 499W
338296-B21
Ultra320 Dual Bus I/O Module for MSA30
287483-B21
Ultra320 Single Bus I/O Module for MSA30
287484-B21
HP StorageWorks
HP StorageWorks
HP StorageWorks
HP StorageWorks
Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500
Modular Smart Array 500
HP StorageWorks Modular Smart Array 500 Generation 2
NOTE:
NOTE:
NOTE:
NOTE: Please see the Modular Smart Array 500 Generation 2 QuickSpecs for
additional information including configuration steps and additional options needed
for a complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11956_na/11956_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11956_div/11956_div.HTML
(Worldwide)
335880-B21
HP StorageWorks
HP StorageWorks
HP StorageWorks
HP StorageWorks
Modular Smart Array
Modular Smart Array
Modular Smart Array
Modular Smart Array
1500 cs
1500 cs
1500 cs
1500 cs
Modular Smart Array 1500 Controller Shelf
AA986A
NOTE:
NOTE:
NOTE:
NOTE: Please see the StorageWorks Modular SAN Array 1500 cs QuickSpecs for
additional options and configuration information at:
http://www.hp.com/go/MSA1500cs
HP StorageWorks
HP StorageWorks
HP StorageWorks
HP StorageWorks
Modular Smart Array
Modular Smart Array
Modular Smart Array
Modular Smart Array
1000
1000
1000
1000
HP StorageWorks Modular Smart Array 1000
201723-B22
NOTE:
NOTE:
NOTE:
NOTE: Please see the Modular Smart Array 1000 QuickSpecs for additional options
and configuration information at
http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.HTML
(Worldwide)
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 26
StorageWorks SAN Switch 2/16
322118-B21
StorageWorks SAN Switch 2/8-EL Upgrade Kit
325888-B21
StorageWorks SAN Switch 2/16-EL Upgrade Kit
325889-B21
StorageWorks Director 2/64
286809-B21
NOTE:
NOTE:
NOTE:
NOTE: Please see the StorageWorks Director 2/64 QuickSpecs for additional
information:
http://h18000.www1.hp.com/products/quickspecs/11003_na/11003_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11003_div/11003_div.HTML
(Worldwide)
UPS and PDU Power
UPS and PDU Power
UPS and PDU Power
UPS and PDU Power
Cord Matrix
Cord Matrix
Cord Matrix
Cord Matrix
Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and
Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and
Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and
Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and
specifications for UPS and PDU units:
specifications for UPS and PDU units:
specifications for UPS and PDU units:
specifications for UPS and PDU units:
ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf.
Uninterruptible Power
Uninterruptible Power
Uninterruptible Power
Uninterruptible Power
Systems – Rack
Systems – Rack
Systems – Rack
Systems – Rack
HP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage (NA)
204404-001
HP UPS R1500 XR (1500VA, 1340 Watt), High Voltage (Int’l)
204404-B31
HP UPS R1500 XR (1500VA, 1340 Watt), Low Voltage (Japan)
204404-291
HP UPS R3000 XR (2880VA, 2700 Watt), Low Voltage (NA)
192186-001
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (NA)
192186-002
HP UPS R3000 XR (2400VA, 2250 Watt), Low Voltage (Japan)
192186-291
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (Japan)
192186-292
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (Int’l - detachable cord)
192186-B31
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A IEC309 Plug)
192186-B32
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A CEE 7/7 SCHUKO
Plug)
192186-B33
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A BS-546 Plug)
192186-AR1
HP UPS R5500 XR (5000VA, 4500 Watt) High Voltage (NA/JPN, L6-30P)
326529-D71
HP UPS R5500 XR (6000VA, 5400 Watt) High Voltage (Int'l, IEC-309)
326529-B31
HP UPS R12000 XR N+x (12000VA, 12000 Watt) (WW-hardwired)
207552-B22
NOTE:
NOTE:
NOTE:
NOTE: The UPS R12000 XR has a hardwired input and output connection.
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 27
HP Power Distribution
HP Power Distribution
HP Power Distribution
HP Power Distribution
Unit with Power
Unit with Power
Unit with Power
Unit with Power
Monitoring
Monitoring
Monitoring
Monitoring
HP Power Distribution Unit with Power Monitoring Model S2324 - dual input, 3
phase, 24A (NA/JPN)
370959-D71
HP Power Distribution Unit with Power Monitoring Model S1324 - single input, 3
phase, 24A (NA/JPN)
370960-D71
HP Power Distribution Unit with Power Monitoring Model S2140 - dual input, 1
phase, 40A (NA/JPN)
370961-D71
HP Power Distribution Unit with Power Monitoring Model S1140 - single input, 1
phase, 40A (NA/JPN)
370962-D71
HP Power Distribution Unit with Power Monitoring Model S2316 - dual input, 3
phase, 16A (INTL)
370963-B31
HP Power Distribution Unit with Power Monitoring Model S1316 - single input, 3
phase, 16A (INTL)
370964-B31
HP Power Distribution Unit with Power Monitoring Model S2132 - dual input, 1
phase, 32A (INTL)
370965-B31
HP Power Distribution Unit with Power Monitoring Model S1132 - single input, 1
phase, 32A (INTL)
370966-B31
Modular Power
Modular Power
Modular Power
Modular Power
Distribution Units 1U/0U
Distribution Units 1U/0U
Distribution Units 1U/0U
Distribution Units 1U/0U
(Up to 32 outlets)
NOTE:
NOTE:
NOTE:
NOTE: 1U/0U mounting
brackets shipped with
the unit (optimized for
10000 and 9000 series
racks).
HP Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC)
(NA, Japan)
NOTE:
NOTE:
NOTE:
NOTE: This mPDU (252663-D71) may also be used to connect the low volt model of
the UPS R3000 XR.
252663-D71
HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC)
(NA, Japan)
252663-D72
HP Modular Power Distribution Units (mPDU), High Volt Model, 32A (200-240 VAC)
(Int'l)
252663-B31
HP Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240 VAC)
(WW)
252663-B21
NOTE:
NOTE:
NOTE:
NOTE: This mPDU (252663-B21), 40A model has a hardwired input.
HP Modular Power Distribution Units (mPDU), High Volt Model, 16A (200-240 VAC)
(WW)
252663-B24
NOTE:
NOTE:
NOTE:
NOTE: This PDU has a detachable input power cord and allows for adaptability to
country specific power requirements. This model may also be used with the high volt
UPS R3000 XR. For North America, need to order cable PN 340653-001.
NOTE:
NOTE:
NOTE:
NOTE: Please see the following Modular Power Distribution Unit (Zero-U/1U
Modular PDUs) QuickSpecs for additional options including shorter jumper cables
and country specific power cords:
http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11041_div/11041_div.HTML
(Worldwide)
USB Options
USB Options
USB Options
USB Options
HP USB 2-Button Optical Scroll Mouse (Carbonite/Silver)
DC172B
USB 1.44-MB External Diskette Drive (Carbonite)
DC141B
256MB HP Drive Key (USB 2.0)
PH657A
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 28
Please see the Enterprise Configurator for configuration assistance at:
http://www.hp.com/products/configurator.
Third Party Rack Kit
Third Party Rack Kit
Third Party Rack Kit
Third Party Rack Kit
DL585 rack model support:
The DL580 G2/585 Third Party rack kit 287528-B21 provides support for any rack,
square hole or round hole, (including HP Rack System /E and HP Systems), with an
adjustment range from 23 ½" – 34" deep.
NOTE:
NOTE:
NOTE:
NOTE: The Third party rack kit is required for round hole racks or for square hole
racks that do not conform to the adjustment range of the standard rail that ships with
the server.
287528-B21
Telco Rack Support
Telco Rack Support
Telco Rack Support
Telco Rack Support
DL585 rack model support:
Support for all 2-post Telco racks requires the Third Party option kit 287528-B21,
plus an additional option kit from Rack Solutions. The Rack Solutions brackets can be
purchased at: http://www.racksolutions.com/hp.
287528-B21
Rack Adapter Kit
NOTE:
NOTE:
NOTE:
NOTE: This kit allows HP rack servers to fit in racks that are 24" wide.
332815-B21
HP Rack 5000 Series
HP Rack 5000 Series
HP Rack 5000 Series
HP Rack 5000 Series
(Graphite Metallic)
HP 5642 Rack-Unassembled
358254-B21
Rack Options for Rack
Rack Options for Rack
Rack Options for Rack
Rack Options for Rack
5000 Series
5000 Series
5000 Series
5000 Series
Stabilizer Kit for 5642 Rack (Graphite Carbon)
NOTE:
NOTE:
NOTE:
NOTE: The stabilizing kit is used to prevent rack from tipping over.
374493-B21
Baying Kit for 5642 Rack (Graphite Carbon)
NOTE:
NOTE:
NOTE:
NOTE: The baying kit is used to join two or more HP 5642 racks.
374499-B21
HP Rack 10000 Series
HP Rack 10000 Series
HP Rack 10000 Series
HP Rack 10000 Series
(Graphite Metallic)
Rack, HP Infrastructure 42U (HV)
379005-001
Rack, HP Infrastructure 42U (LV)
379006-001
HP Rack S10614 (14U) Rack Cabinet – Shock Pallet
292302-B22
HP Rack 10842 (42U, 800mm wide) – Pallet
257415-B21
HP Rack 10842 (42U, 800mm wide) – Shock Pallet
257415-B22
HP Rack 10647 (47U) – Pallet
245160-B21
HP Rack 10647 (47U) – Crated
245160-B23
HP Rack 10642 (42U) – Pallet
245161-B21
HP Rack 10642 (42U) – Shock Pallet
245161-B22
HP Rack 10642 (42U) – Crated
245161-B23
HP Rack 10636 (36U) – Pallet
245162-B21
HP Rack 10636 (36U) – Shock Pallet
245162-B22
HP Rack 10636 (36U) – Crated
245162-B23
HP Rack 10622 (22U) – Pallet
245163-B21
HP Rack 10622 (22U) – Shock Pallet
245163-B22
HP Rack 10622 (22U) – Crated
245163-B23
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 29
NOTE: -B21 (pallet) used to ship empty racks shipped on a truck
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems,
VARs and Channels)
-B23 (crated) used for air shipments of empty racks
NOTE:
NOTE:
NOTE:
NOTE: Please see the Rack 10000 QuickSpecs for Technical Specifications such as
height, width, depth, weight, and color:
http://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.HTML
(Worldwide)
http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.HTML
(North America)
NOTE:
NOTE:
NOTE:
NOTE: For additional information regarding Rack Cabinets, please see the following
URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-
options/index.html.
Rack Options for HP
Rack Options for HP
Rack Options for HP
Rack Options for HP
Rack 10000 Series
Rack 10000 Series
Rack 10000 Series
Rack 10000 Series
NOTE:
NOTE:
NOTE:
NOTE: For additional information regarding Rack Options, please see the following
URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-
options/index.html.
HP Rack Light Kit (Neon)
361589-B21
HP Rack Plinth Kit (Carbon)
251960-B21
42U Side Panel – Graphite Metallic
246099-B21
36U Side Panel – Graphite Metallic
246102-B21
47U Side Panel – Graphite Metallic
255486-B21
TFT5600 Rack Keyboard Monitor
221546-xx1
Country Code Key
Country Code Key
Country Code Key
Country Code Key (for TFT5600 Rack Keyboard Monitor (PN 221546-xx1))
XX = 001
US
XX = 091
Norway
XX = 031
UK
XX = 101
Sweden/Finland
XX = 041
Germany
XX = 111
Switzerland
XX = 051
France
XX = 131
Portugal
XX = 061
Italy
XX = 181
Belgium
XX = 071
Spain
XX = 291
Japan
XX = 081
Denmark
XX = B31
International
1U Rack Keyboard & Drawer (Carbon)
257054-xx1
Country Code Key
Country Code Key
Country Code Key
Country Code Key (for 1U Rack Keyboard & Drawer (PN 257054-xx1))
XX = 001
US
XX = 091
Norway
XX = 031
UK
XX = 101
Sweden/Finland
XX = 041
Germany
XX = 111
Switzerland
XX = 051
France
XX = 131
Portugal
XX = 061
Italy
XX = 181
Belgium
XX = 071
Spain
XX = 291
Japan
XX = 081
Denmark
XX = B31
International
NOTE:
NOTE:
NOTE:
NOTE: For additional information regarding Rack Options, please see the following
URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rack-
options/index.html
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 30
HP KVM Switch Options
HP KVM Switch Options
HP KVM Switch Options
HP KVM Switch Options
Server Console Switch (KVM), 0 x 1 x 8 port
336044-B21
Server Console Switch (KVM), 0 x 2 x 16 port
336045-B21
IP Console Switch Box (KVM/IP), 1 x 1 x 16
262585-B21
IP Console Switch Box (KVM/IP), 3 x 1 x 16
262586-B21
PS/2 Interface Adapter, 8 pack
262587-B21
PS/2 Interface Adapter, 1 pack
262588-B21
CAT5 KVM USB Interface Adapter
336047-B21
CAT5 KVM Expansion Module
262589-B21
CAT5 KVM Serial Interface Adapter
373035-B21
CAT5e Cable 3', 4 pack
263474-B21
CAT5e Cable 6', 8 pack
263474-B22
CAT5e Cable 12', 8 pack
263474-B23
CAT5e Cable 20', 4 pack
263474-B24
CAT5e Cable 40', 1 pack
263474-B25
HP 1x4 USB/PS2 KVM Switch, RM (ALL)
371302-B21
HP 1x4 USB/PS2 KVM Switch, TT, (EURO)
371301-A21
HP 1x4 USB/PS2 KVM Switch, TT (UK)
371301-031
HP 1x4 USB/PS2 KVM Switch, TT, (AUST/NZ)
371301-011
HP 1x4 USB/PS2 KVM Switch, TT, (NA/JPN)
371301-D71
HP 6ft, 2-Pack, PS2 with audio KVM cable
371730-B21
HP 6ft, 2-Pack, USB with audio KVM cable
371729-B21
NOTE:
NOTE:
NOTE:
NOTE: For additional information regarding HP KVM Switches and options, please see
the following URL:
http://h18004.www1.hp.com/products/servers/proliantstorage/rack-
options/list.html#console
Service and Support
Service and Support
Service and Support
Service and Support
Offerings
Offerings
Offerings
Offerings (HP Care Pack
Services)
Hardware Services On-site Service
Hardware Services On-site Service
Hardware Services On-site Service
Hardware Services On-site Service
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years
U4607A
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
U4607E
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years
U4608A
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
U4608E
6-Hour Call to Repair, On-site Service 7-Day x 24-Hour Coverage, 3 Years
6-Hour Call to Repair, On-site Service 7-Day x 24-Hour Coverage, 3 Years
6-Hour Call to Repair, On-site Service 7-Day x 24-Hour Coverage, 3 Years
6-Hour Call to Repair, On-site Service 7-Day x 24-Hour Coverage, 3 Years
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years
U4609A
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
U4609E
Installation & Start-up Services
Installation & Start-up Services
Installation & Start-up Services
Installation & Start-up Services
Hardware Installation
U4617A
Hardware Installation, Electronic
U4617E
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the
Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-
5pm, M-F, excl. HP holidays.
U4618A
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the
Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-
5pm, M-F, excl. HP holidays, Electronic
U4618E
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 31
Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech
support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP
holidays.
U4619A
Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech
support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP
holidays, Electronic
U4619E
Support Plus 24
Support Plus 24
Support Plus 24
Support Plus 24
Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite,
onsite at HP's discretion, 24x7 2hr response time incl. HP holidays.
U4620A
Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite,
onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic
U4620E
Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite,
onsite at HP's discretion, 24x7 2hr response time incl. HP holidays.
U6316A
Onsite HW support 24x7, 4hr response and SuSE Linux SW Tech support offsite,
onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic
U6316E
Onsite HW support 24x7, 4hr response and Red Hat AS Linux SW Tech support
offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays.
U9239A
Onsite HW support 24x7, 4hr response and Red Hat AS Linux SW Tech support
offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic
U9239E
NOTE:
NOTE:
NOTE:
NOTE: For more information, customer/resellers can contact:
http://www.hp.com/services/carepack
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Options
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 32
NOTE: Memory configurations listed do not apply to "Factory Integrated Models."
HP ProLiant DL585 2P Models
HP ProLiant DL585 2P Models
HP ProLiant DL585 2P Models
HP ProLiant DL585 2P Models
Standard Memory
Standard Memory
Standard Memory
Standard Memory
4GB PC3200 Double Data Rate (DDR) SDRAM (Registered SDRAM) memory running at 400MHz or
2GB PC2100 Double Data Rate (DDR) SDRAM (Registered SDRAM) memory running at 266MHz or
2GB PC2700 Double Data Rate (DDR) SDRAM (Registered SDRAM) memory running at 333MHz with Advanced ECC
Rules:
Must install a minimum of 2 DIMMs in the processor memory board in slot 2
DIMMs on a processor memory board must be installed in pairs and in bank order
All DIMMs on a processor memory board must be of the same size (512 MB, 1 GB, or 2 GB)
Each processor memory board can have different amounts of memory, ex. Processor memory board 2 = (4) 1 GB, Processor
memory board 1 = (2) 512 MB, Processor memory board 4 = no memory
PC2700 memory support requires -002 processor board
333MHz memory performance requires no more than 6 PC2700 DIMMs per processor board; any more will result in the
memory slowing down to 266MHz
PC3200 memory, running at 400MHz will be supported on a PC3200-only processor board (012567-001) with 4 DIMM
slots, resulting in a system max of 32GB with 4 processors
The following memory options are available from HP:
1GB of PC2100 DDR SDRAM DIMM Memory Kit (2x512 MB)
300679-B21
2GB of PC2100 DDR SDRAM DIMM Memory Kit (2x1 GB)
300680-B21
4GB of PC2100 DDR SDRAM DIMM Memory Kit (2x2 GB)
300682-B21
1GB of PC2700 DDR SDRAM DIMM Memory (2x512 MB)
371047-B21
2GB of PC2700 DDR SDRAM DIMM Memory (2x1 GB)
371048-B21
4GB of PC2700 DDR SDRAM DIMM Memory (2x2 GB)
371049-B21
2GB of PC3200 DDR SDRAM DIMM Memory (2x1 GB)
376639-B21
4GB of PC3200 DDR SDRAM DIMM Memory (2x2 GB)
379300-B21
Standard Memory Configuration
Standard Memory Configuration
Standard Memory Configuration
Standard Memory Configuration
Total Memory = 2 GB
1111
2222
3333
4444
5555
6666
7777
8888
Board 1
Board 1
Board 1
Board 1
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Board 2
Board 2
Board 2
Board 2
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Empty
Board 3
Board 3
Board 3
Board 3 (optional)
Not
Not
Not
Not
installed
installed
installed
installed
_
_
_
_
_
_
_
Board 4
Board 4
Board 4
Board 4 (optional)
Not
Not
Not
Not
installed
installed
installed
installed
_
_
_
_
_
_
_
Examples of other optional configurations include, but are not limited to:
Example #1: Optional Memory Configuration
Example #1: Optional Memory Configuration
Example #1: Optional Memory Configuration
Example #1: Optional Memory Configuration
Standard Memory plus Optional Processor Memory Boards and Processors
Total Memory = 32 GB
1111
2222
3333
4444
5555
6666
7777
8888
Board 1
Board 1
Board 1
Board 1
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
Board 2
Board 2
Board 2
Board 2
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
512 MB
Board 3
Board 3
Board 3
Board 3 (optional)
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
Board 4
Board 4
Board 4
Board 4 (optional)
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
1 GB
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Memory
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 33
Example #2: Maximum Memory Configuration
Example #2: Maximum Memory Configuration
Example #2: Maximum Memory Configuration
Example #2: Maximum Memory Configuration
Maximum Memory (Standard replaced with Optional Memory and Optional Memory Board)
Total Memory = 64 GB
1111
2222
3333
4444
5555
6666
7777
8888
Board 1
Board 1
Board 1
Board 1
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
Board 2
Board 2
Board 2
Board 2
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
Board 3
Board 3
Board 3
Board 3 (optional)
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
Board 4
Board 4
Board 4
Board 4 (optional)
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
2 GB
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Memory
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 34
Diskette Drive eject button
B
Ejectable: 24x IDE CD-ROM (Slimline)
C
Ejectable: 1.44-MB Diskette Drive (Slimline)
D
CD-ROM Drive eject button
E
870 Watt (low line or high line) Redundant Hot Plug Power Supply
F
870 Watt (low line or high line) Primary Hot Plug Power Supply
0-3
Wide Ultra3 Drive Cage (Duplex or Simplex configurable). Duplex
is standard shipping configuration
Drive Support
Drive Support
Drive Support
Drive Support
Quantity
Quantity
Quantity
Quantity
Supported
Supported
Supported
Supported
Position
Position
Position
Position
Supported
Supported
Supported
Supported
Controller
Controller
Controller
Controller
Ejectable Slim-line Drives
Ejectable Slim-line Drives
Ejectable Slim-line Drives
Ejectable Slim-line Drives
1.44-MB slim-line Diskette
Drive
Up to 1
C
Integrated
IDE slim-line CD-ROM
Drive
Up to 1
B
Integrated IDE
Slimline DVD-ROM Drive
(8X/24X) Option Kit
Up to 1
B or C
Integrated IDE
Hard Drives
Hard Drives
Hard Drives
Hard Drives
Ultra320 Hot Pluggable Drives
Ultra320 Hot Pluggable Drives
Ultra320 Hot Pluggable Drives
Ultra320 Hot Pluggable Drives
Quantity
Quantity
Quantity
Quantity
Supported
Supported
Supported
Supported
Position
Position
Position
Position
Supported
Supported
Supported
Supported
Controller
Controller
Controller
Controller
1-inch
1-inch
1-inch
1-inch
300-GB 10,000 rpm
146.8-GB 10,000 rpm
72.8-GB 10,000 rpm
148.8-GB 15,000 rpm
72.8-GB 15,000 rpm
36.4-GB 15,000 rpm
Up to 4
0-3
Smart Array 5i Plus Controller (integrated on system board)
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 641 Controller
Smart Array 642 Controller
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
NOTE:
NOTE:
NOTE:
NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives require an optional U320
Smart Array Controller or U320 SCSI HBA to support U320 transfer rates.
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Storage
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 35
Host Controller or Adapter
Host Controller or Adapter
Host Controller or Adapter
Host Controller or Adapter
Modular Smart Array 30
Family
Up to 13
External
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate
OS
Modular Smart Array
1000
Please see the
Modular Smart
Array 1000
QuickSpecs
below to
determine
configuration
requirements
External
Please see the Modular Smart Array 1000 QuickSpecs (URL below)
for the latest list of supported HBAs
Modular Smart Array
1500 cs
Please see the
Modular Smart
Array 1500 cs
QuickSpecs
below to
determine
configuration
requirements
External
Please see the Modular Smart Array 1500 cs QuickSpecs (URL
below) for the latest list of supported HBAs
Modular Smart Array 1000:
http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.HTML (Worldwide)
Modular Smart Array 1500 cs: http://www.hp.com/go/MSA1500cs
Maximum Storage Capacity
Maximum Storage Capacity
Maximum Storage Capacity
Maximum Storage Capacity – (External Enclosure Attached)
Internal
1.20 TB (4 x 300 GB Ultra320 SCSI 1" Drives)
External
84.00 TB (20 x (14 x 300 GB Ultra320 SCSI 1" Drives))
Total
85.20 TB
Tape Drives, Tape Autoloaders, and Tape Libraries
Tape Drives, Tape Autoloaders, and Tape Libraries
Tape Drives, Tape Autoloaders, and Tape Libraries
Tape Drives, Tape Autoloaders, and Tape Libraries
NOTE:
NOTE:
NOTE:
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Drives listed below, please see the following:
http://h18000.www1.hp.com/products/quickspecs/North_America/10233.html (North America)
http://h18000.www1.hp.com/products/quickspecs/Division/10233.html (Worldwide)
NOTE:
NOTE:
NOTE:
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Autoloaders & Tape Libraries listed below,
please see the following:
http://h18000.www1.hp.com/products/quickspecs/North_America/10809.html (North America)
http://h18000.www1.hp.com/products/quickspecs/Division/10809.html (Worldwide)
Quantity
Quantity
Quantity
Quantity
Supported
Supported
Supported
Supported
Position
Position
Position
Position
Supported
Supported
Supported
Supported
Controller
Controller
Controller
Controller
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Storage
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 36
HP StorageWorks Tape
HP StorageWorks Tape
HP StorageWorks Tape
HP StorageWorks Tape
Drives, External
Drives, External
Drives, External
Drives, External
Ultrium 215
Ultrium 230
Ultrium 448
Ultrium 460
DAT 72 Tape Drive
DAT 40 Tape Drive
DAT 24 Tape Drive
Up to 2
External
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
HP StorageWorks Tape
HP StorageWorks Tape
HP StorageWorks Tape
HP StorageWorks Tape
Drives, External
Drives, External
Drives, External
Drives, External
Ultrium 960
1
External
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
HP StorageWorks Rack-
HP StorageWorks Rack-
HP StorageWorks Rack-
HP StorageWorks Rack-
mount Tape Drive
mount Tape Drive
mount Tape Drive
mount Tape Drive
Enclosures
Enclosures
Enclosures
Enclosures
1U Rack-Mount Kit
3U Rack-Mount Kit
5U Rack-Mount Kit
1
External
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
HP StorageWorks
HP StorageWorks
HP StorageWorks
HP StorageWorks
Autoloaders, External
Autoloaders, External
Autoloaders, External
Autoloaders, External
DAT 72x6 Tape
Autoloader
1/8 Tape Autoloader
SSL1016 Tape
Autoloader
1 autoloader per
SCSI channel
External
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
HP StorageWorks Tape
HP StorageWorks Tape
HP StorageWorks Tape
HP StorageWorks Tape
Libraries, External
Libraries, External
Libraries, External
Libraries, External
MSL6000 (Ultrium 960 -
based)
MSL6000 (SDLT 600-
based)
MSL6000 (Ultrium 460 -
based)
MSL5026S2 (SDLT 320-
based)
MSL5052S2 (SDLT 320-
based)
Please reference
the MSL Tape
Library
QuickSpecs to
determine
configuration
requirements
External
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
HP StorageWorks ESL E-
HP StorageWorks ESL E-
HP StorageWorks ESL E-
HP StorageWorks ESL E-
Series Tape Libraries
Series Tape Libraries
Series Tape Libraries
Series Tape Libraries
ESL 712e
ESL 630e
ESL 322e
ESL 286e
Please reference
the ESL E-series
Tape Libraries
QuickSpecs to
determine
configuration
requirements
External
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate
OS
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Storage
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 37
Operational Input Voltage
Operational Input Voltage
Operational Input Voltage
Operational Input Voltage
Range (V rms)
Range (V rms)
Range (V rms)
Range (V rms)
90 to 264
Frequency Range (Nominal)
Frequency Range (Nominal)
Frequency Range (Nominal)
Frequency Range (Nominal)
(Hz)
(Hz)
(Hz)
(Hz)
47 to 63 (50/60)
Nominal Input Voltage (Vrms)
Nominal Input Voltage (Vrms)
Nominal Input Voltage (Vrms)
Nominal Input Voltage (Vrms)
100
100
100
100
115
115
115
115
208
208
208
208
220
220
220
220
230
230
230
230
240
240
240
240
Max Rated Output Wattage Rating
800
800
800
800
800
800
Nominal Input Current (A rms)
11.7
9.9
5.2
4.9
4.7
4.5
Max Rated Input Wattage Rating (Watts)
1143
1111
1067
1067
1067
1053
Max. Rated VA (Volt-Amp)
1166
1134
1088
1088
1088
1074
Efficiency (%)
70
72
75
75
75
76
Power Factor
0.98
0.98
0.98
0.98
0.98
0.98
Leakage Current (mA)
.43
.50
.90
.96
1.00
1.04
Maximum Inrush Current (A peak)
25
25
25
25
25
25
Maximum Inrush Current duration
20
20
20
20
20
20
System Specifications
System Specifications
System Specifications
System Specifications
DL585 Fully Configured
DL585 Fully Configured
DL585 Fully Configured
DL585 Fully Configured
4 processors, 32 memory modules, 4 hard drives, 8 PCI-X expansion cards, 8 hot plug fans, and 2 hot plug power supplies.
Nominal Input Voltage (Vrms)
Nominal Input Voltage (Vrms)
Nominal Input Voltage (Vrms)
Nominal Input Voltage (Vrms)
100
100
100
100
115
115
115
115
208
208
208
208
220
220
220
220
230
230
230
230
240
240
240
240
Fully Loaded System Input Wattage (W)
954
928
890
890
890
879
Fully Loaded System Input Current (A rms)
10
8.5
4.4
4.1
4.0
3.7
Fully Loaded System Thermal (BTU- Hr)
3253
3163
3063
3063
3063
2996
Fully Loaded System VA (Volt-Amp)
1004
976
909
909
909
897
System Leakage with all power supplies loaded
(mA)
.87
1.00
1.81
1.91
2.00
2.09
System Inrush Current with all power supplies
loaded (A)
50
50
50
50
50
50
Power cord requirements
Nema 5-15P to IEC320-C19
Option no./Spare no: 235603-
001/237457-001
PDU Jumper Cord IEC320-C19 to
IEC320-C20
Option no./Spare no: 295633-
B21/295508-001
PDU Jumper Cord IEC320-C14 to
IEC320-C19
Option no./Spare no: 291034-
001/292241-001
NOTES
NOTES
NOTES
NOTES:
* To review typical system power ratings use the Active Answers Power Calculator which is available via the online tool located at
URL: http://h30099.www3.hp.com/configurator/powercalcs.asp.
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL585
- Click on: "Power Calculator" link (You may need to scroll down to see it.)
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Power Specifications
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 38
Power Cord Part Number
Power Cord Part Number
Power Cord Part Number
Power Cord Part Number
Country
Country
Country
Country
US
295529-001
AUST
295529-011
EURO
295529-021
UK
295529-031
Japan
295529-291
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Power Specifications
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 39
System Unit Rack
System Unit Rack
System Unit Rack
System Unit Rack
Chassis Footprint
Chassis Footprint
Chassis Footprint
Chassis Footprint
(HxWxD)
6.94 x 19 x 26.5 in (17.6 x 48.3 x 67.3 cm)
Weight
Weight
Weight
Weight
No hard drives installed,
one power supply
66 lb (29.9 kg)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
Rated Input Voltage
100 to 120 VAC/200 to 240 VAC
Rated Input Frequency
50 to 60 Hz
Input Power
1135W @ 110 VAC/1125W @ 220 VAC
Rated Input Current
12A (100 VAC), 9.8A (120 VAC), 4.9A (220
VAC)
Max BTU Rating
Max BTU Rating
Max BTU Rating
Max BTU Rating
4000 BTU
Power Specifications
Power Specifications
Power Specifications
Power Specifications
To review typical system power ratings use the Active Answers Power
Calculator which is available via the online tool located at URL:
http://h30099.www3.hp.com/configurator/powercalcs.asp.
To drill down to calculators:
Click on: "ProLiant Servers"
Click on the Server of interest. Example: DL585
Click on: "Power Calculator" link (You may need to scroll down to see
it.)
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
Power
Power
Power
Power (per power supply)
Rated Steady-State Power
800W/800W (lowline/highline)
Maximum Peak Power
800W/800W (lowline/highline)
Temperature Range
Temperature Range
Temperature Range
Temperature Range
Operating
50° to 95° F (10° to 35° C)
Non-operating
-20° to 140° F (-29° to 60° C)
Shipping
-22° to 122° F (-30° to 50° C)
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Operating
10% to 70%
Non-operating
5% to 95%
Maximum Wet Bulb
Maximum Wet Bulb
Maximum Wet Bulb
Maximum Wet Bulb
Temperature
Temperature
Temperature
Temperature
101.7° F (38.7° C)
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
NOTE:
NOTE:
NOTE:
NOTE: Listed are the declared A-weighted sound power levels LWAd and the
declared average bystander position sound pressure levels LpAm when
operating in a 23° C ambient environment. Noise emissions were measured
in accordance with ECMA 74 and declared in accordance with ECMA 109.
Idle (Fixed Disk Drives
Spinning)
LLLL WAd (BELS)
7.3
L L L L pAm (dBA)
55
Operating Minimum
(Random Seeks to Fixed
Disks)
L L L L WAd (BELS)
7.3
LLLL pAm (dBA)
55
NOTE:
NOTE:
NOTE:
NOTE: These values apply to 4U rack configuration with the Health Driver
Fan Control active. Configuration tested included 2 AMD Opteron 2.2 GHz
processors, 1 15 krpm hard drive, 2 power supplies, 4 memory/IO fans and
4 CPU fans.
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Technical Specifications
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 40
24X Max (or higher) IDE
24X Max (or higher) IDE
24X Max (or higher) IDE
24X Max (or higher) IDE
CD-ROM Drive Slim Line
CD-ROM Drive Slim Line
CD-ROM Drive Slim Line
CD-ROM Drive Slim Line
Disk
Disk
Disk
Disk
Applicable Disk
CD-DA, CD-ROM (Mode 1 and 2)
CD-XA, CD-I (Mode 2, Form 1 and 2)
Photo CD (Single and Multi-session)
Mixed Mode (Audio and Data combined)
Capacity
540 MB (Mode 1, 12 cm)
650 MB (Mode 2, 12 cm)
Diameter
4.7 x 3.15 in (12 x 8 cm)
Rotational Speed
4200 rpm maximum
Center Hole
0.6 in/15 mm diameter
Thickness
1.2 mm
Track Pitch
1.6 µm
Block Size
Block Size
Block Size
Block Size
Mode 1
2,048
Mode 2
2,340, 2,336, 1,024 bytes
CD-DA
2,352 bytes
CD-XA
2,328 bytes
Interface
Interface
Interface
Interface
IDE (ATAPI)
Access Times
Access Times
Access Times
Access Times (typical)
(typical)
(typical)
(typical)
Random
100 ms
Full-Stroke
2000 ms
Audio Output Level
Audio Output Level
Audio Output Level
Audio Output Level
Line-Out
0.7 VRMS at 47 kOhms
Headphone
0.6 VRMS at 32 kOhms (maximum volume)
Data Transfer Rate
Data Transfer Rate
Data Transfer Rate
Data Transfer Rate
Sustained
150 KB/s (sustained 1X)
Burst
2100 to 3600 KB/s
Cache Buffer
Cache Buffer
Cache Buffer
Cache Buffer
128 KB
Start-up Time
Start-up Time
Start-up Time
Start-up Time (typical)
(typical)
(typical)
(typical)
< 7seconds
Stop Time
Stop Time
Stop Time
Stop Time
< 4seconds
Laser Parameters
Laser Parameters
Laser Parameters
Laser Parameters
Type
Semiconductor Laser GaA1As
Wave Length
780 ± 25 nm
Divergence Angle
53.5° ± 1.5°
Output Power
0.14 mW
Operating Conditions
Operating Conditions
Operating Conditions
Operating Conditions
Temperature
41° to 113° F (5° to 45° C)
Humidity
10% to 80%
Dimensions
Dimensions
Dimensions
Dimensions
(HxWxD, maximum)
1.69 x 5.75 x 8.19 in (4.29 x 15 x 20.8 cm)
Weight
2.66 lb (1.2 kg)
Slim Line CD-RW/DVD-
Slim Line CD-RW/DVD-
Slim Line CD-RW/DVD-
Slim Line CD-RW/DVD-
ROM 24X Combo Drive
ROM 24X Combo Drive
ROM 24X Combo Drive
ROM 24X Combo Drive
(Multibay)
(Multibay)
(Multibay)
(Multibay)
Shipping Dimensions
Shipping Dimensions
Shipping Dimensions
Shipping Dimensions
13.88 x 11.38 x 9.25 in (35.26 x 28.91 x 23.50 cm)
Shipping Weight
Shipping Weight
Shipping Weight
Shipping Weight
5 lb (2.27 kg)
Disk
Disk
Disk
Disk
Applicable Disk
Applicable Disk
Applicable Disk
Applicable Disk
DVD-ROM
DVD-R (Read Only)
2.6 GB/side DVD-RAM (Read Only)
5.2 GB/side DVD-RAM (Read Only)
CD-ROM Mode-1 data disc
CD-ROM Mode-2 data disc
CD Audio disc
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Technical Specifications
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 41
CD-I (mode 2)
CD-I Ready
CD-Bridge
Capacity
DVD-ROM
DVD-SL
4.7 GB/side
DVD-DL
8.5 GB/side
Double
Sided
9.40 GB/side
DVD-R
3.95 GB/side
DVD-RAM
2.6 GB/side and
5.2 GB/
CD-ROM
Mode-1
650 MB (550 MB)
Mode-2
742 MB (640 MB)
Block Size
DVD
2,048 bytes
CD
2,352 (Mode-0)
2352, 2340,
2336, 2048 bytes
(Mode-1)
2352, 2340,
2336, 2048 bytes
(Mode-2)
Diameter
120 mm, 80 mm (with adapter at vertical
mounting mode)
Loading Mechanism
Loading Mechanism
Loading Mechanism
Loading Mechanism
Tray type
Interface
Interface
Interface
Interface
EIDE (ATAPI)
Access Times (typical)
Access Times (typical)
Access Times (typical)
Access Times (typical)
Random
DVD-ROM < 120 ms, CD-ROM < 110 ms
Full-Stroke
DVD-ROM < 240 ms, CD-ROM < 160 ms
Audio Output Level
Audio Output Level
Audio Output Level
Audio Output Level
(typical)
(typical)
(typical)
(typical)
Line-out
CD 0.7 Vrms at 47 Kohms Load
Data Transfer Rate
Data Transfer Rate
Data Transfer Rate
Data Transfer Rate
(sustained)
(sustained)
(sustained)
(sustained)
DVD-ROM
Single Layer
10.8 MB/sec. Max.
DVD-RAM
2.77 MB/sec. Max
CD-ROM
7.2 MB/sec. Max.
Cache Buffer
Cache Buffer
Cache Buffer
Cache Buffer
2 MB
Spin-up Time (typical)
Spin-up Time (typical)
Spin-up Time (typical)
Spin-up Time (typical)
less than 10 seconds
MTBF
MTBF
MTBF
MTBF
120,000 Power On Hours
(POH)
Ambient Temperature
Ambient Temperature
Ambient Temperature
Ambient Temperature
Operating
-22° to 140° F (-30° to 60° C)
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
Operating
10% to 80%
Storage/Transportation
5% to 95%
Dimensions
Dimensions
Dimensions
Dimensions
(HxWxD, maximum)
0.5 x 5.04 x 5.1 in (12.7x128x129.4 mm)
Option Kit Contents
Option Kit Contents
Option Kit Contents
Option Kit Contents
DVD-ROM drive with installation guide, warranty card, registration card
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Technical Specifications
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 42
Standard (integrated on
Standard (integrated on
Standard (integrated on
Standard (integrated on
system board)
system board)
system board)
system board)
Architecture
Architecture
Architecture
Architecture
32-bit PCI-based health and remote management ASIC (Application Specific
Integrated Circuit)
Processor
Processor
Processor
Processor
32-bit RISC processor core running at 66 MHz
Upgradeability
Upgradeability
Upgradeability
Upgradeability
Option firmware upgradeable via flash ROM.
Video Support
Video Support
Video Support
Video Support
Utilizes the host server's embedded video chip. Supports VGA/SVGA, 640 x
480 (256 to 16.7M colors), 800 x 600 (256 to 16.7M colors), 1024 x 768
(256 to 65K colors), 1280 x 1024 (256 colors)
Interfaces
Interfaces
Interfaces
Interfaces
One Ethernet network connection (10/100 Mb/s)
Memory
Memory
Memory
Memory
2-MB Flash ROM
8-MB SDRAM
Operating System
Operating System
Operating System
Operating System
Support
Support
Support
Support
Windows 2000 Server
Windows 2000 Advanced Server
Red Hat 7.x
SuSE 7.0
Client Browser Support
Client Browser Support
Client Browser Support
Client Browser Support
Microsoft Internet Explorer 5.5 or later.
iLO Standard Features
iLO Standard Features
iLO Standard Features
iLO Standard Features
Virtual Text Remote Console
Virtual Power Button Control
Dedicated LAN Connectivity
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) Security
IML and iLO Event Logging
Support for up to 12 user accounts with customizable access privileges
iLO Advanced Features
iLO Advanced Features
iLO Advanced Features
iLO Advanced Features
(optional)
Virtual Graphical Remote Console
Virtual Floppy Drive
Integrated Smart Array 5i
Integrated Smart Array 5i
Integrated Smart Array 5i
Integrated Smart Array 5i
Plus Controller
Plus Controller
Plus Controller
Plus Controller
Data Compatible with all
Data Compatible with all
Data Compatible with all
Data Compatible with all
Smart Array Controllers
Smart Array Controllers
Smart Array Controllers
Smart Array Controllers
Yes
Instant Upgrades to other
Instant Upgrades to other
Instant Upgrades to other
Instant Upgrades to other
Smart Array Controllers
Smart Array Controllers
Smart Array Controllers
Smart Array Controllers
Yes
Consistent Software
Consistent Software
Consistent Software
Consistent Software
Manageability Tools
Manageability Tools
Manageability Tools
Manageability Tools
Yes
PCI-X Bus
PCI-X Bus
PCI-X Bus
PCI-X Bus
64-bit, 100 MHz (integrated on system board)
PCI-X Peak Data Transfer
PCI-X Peak Data Transfer
PCI-X Peak Data Transfer
PCI-X Peak Data Transfer
Rate
Rate
Rate
Rate
800 MB/s
SCSI Protocols Supported
SCSI Protocols Supported
SCSI Protocols Supported
SCSI Protocols Supported Ultra3, Ultra2
SCSI Peak Data Transfer
SCSI Peak Data Transfer
SCSI Peak Data Transfer
SCSI Peak Data Transfer
Rate
Rate
Rate
Rate
160 MB/s per channel
NOTE:
NOTE:
NOTE:
NOTE: For ProLiant servers having TWO internal drive bays on separate SCSI ports: SCSI Peak Data
Transfer Rate is 320 MB/s total; 160 MB/s per channel and Channels is 2.
Channels
Channels
Channels
Channels
2 (only one connected)
NOTE:
NOTE:
NOTE:
NOTE: For ProLiant servers having two internal drive bays on separate SCSI ports: SCSI Peak Data
Transfer Rate is 320 MB/s total; 160 MB/s per channel and Channels is 2.
SCSI Ports
SCSI Ports
SCSI Ports
SCSI Ports
(external/internal)
0/1
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Technical Specifications
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 43
NOTE: For ProLiant servers having two internal drive bays on separate SCSI ports: SCSI Peak Data
Transfer Rate is 320 MB/s total; 160 MB/s per channel and Channels is 2.
Drives Supported
Drives Supported
Drives Supported
Drives Supported
(maximum)
2
NOTE:
NOTE:
NOTE:
NOTE: Maximum is the total number of internal drives on each specific ProLiant server.
Cache
Cache
Cache
Cache
64 MB Read and/or Write Cache
Battery-Backed Write
Battery-Backed Write
Battery-Backed Write
Battery-Backed Write
Cache
Cache
Cache
Cache
Yes, with installation of Battery-Backed Write Cache Enabler, up to 64MB
RAID Support
RAID Support
RAID Support
RAID Support
0, 1, 1+0, 5
Logical Drives
Logical Drives
Logical Drives
Logical Drives (maximum) Maximum = total number of drives
Online Configuration
Online Configuration
Online Configuration
Online Configuration
Yes
Online Capacity
Online Capacity
Online Capacity
Online Capacity
Expansion
Expansion
Expansion
Expansion
Yes
Logical Drive Capacity
Logical Drive Capacity
Logical Drive Capacity
Logical Drive Capacity
Extension
Extension
Extension
Extension
Yes
Online Stripe Size
Online Stripe Size
Online Stripe Size
Online Stripe Size
Migration
Migration
Migration
Migration
Yes
Online RAID Level
Online RAID Level
Online RAID Level
Online RAID Level
Migration
Migration
Migration
Migration
Yes
Online Spare Support
Online Spare Support
Online Spare Support
Online Spare Support
Yes
Automatic Data Recovery
Automatic Data Recovery
Automatic Data Recovery
Automatic Data Recovery Yes
Drive Roaming
Drive Roaming
Drive Roaming
Drive Roaming
Yes
Redundant Controllers
Redundant Controllers
Redundant Controllers
Redundant Controllers
No
Dual Port NC7782
Dual Port NC7782
Dual Port NC7782
Dual Port NC7782
Network Interface
Network Interface
Network Interface
Network Interface
10/100/1000-T
Compatibility
Compatibility
Compatibility
Compatibility
IEEE 802.3 10Base-T
IEEE 802.3ab 1000Base-T
IEEE 802.3u 100Base-TX
Data Transfer Method
Data Transfer Method
Data Transfer Method
Data Transfer Method
64-bit/133MHz PCI-X
Network Transfer Rate
Network Transfer Rate
Network Transfer Rate
Network Transfer Rate
10Base-T (Half-Duplex)
10 Mb/s
10Base-T (Full-Duplex)
20 Mb/s
100Base-TX (Half-Duplex) 100 Mb/s
100Base-TX (Full-Duplex)
200 Mb/s
1000Base-TX (Half and
Full-Duplex)
2000 Mb/s
Connector
Connector
Connector
Connector
RJ-45
Cable Support
Cable Support
Cable Support
Cable Support
10Base-T
Category 3, 4 or 5 UTP up to 328 ft (100 m)
10/100/1000Base-T
Category 5 UTP (2 pair); up to 328 ft (100 m)
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Technical Specifications
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 44
© Copyright 2005 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows are US registered trademarks of Microsoft Corporation. AMD, Opteron, and Hyper-Transport are trademarks
of AMD Corporation in the United States and other countries.
Unix is a registered trademark of The Open Group.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial
errors or omissions contained herein.
QuickSpecs
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
HP ProLiant DL585
Technical Specifications
DA - 11902 Worldwide — Version 29 — May 5, 2005
Page 45