Key Pages of Document

Displaying the System Status

The RMC status command displays the system status and the current RMC settings. Table 6–1 explains the status fields. See Section 6.11 for information on the commands used to set the user-defined status fields. RMC> status hp AlphaServer TS15 Platform Status RMC Runtime Firmware Revision: V0.6-5 RMC Booter Firmware Revision: V1.0-0 System Power: ON System Halt: Deasserted Escape Sequence: ^[^[RMC Remote Access: Disabled Modem RMC Defaults: Disabled Status: Not Initialized RMC Password: Not Set Alerts: Disabled Warning Alerts: ...

1.11 Ground and Power Connections

The power supply is designed for dual redundant inputs and both power cables must be installed. A ground cable connects the enclosure to the rack’s vertical rail. Figure 1–15 Ground and Power Connections A B A 1 2 B 3 4 5 1 MR0568 A B 1 3 2 System Overview 1-19 ...

Table 6–4 Initialization Commands with MODEMDEF Enabled

Modem Command Description &C1 Normal Carrier Detect (CD) operations &Kx Select flow control per the current COM1 settings, where x is as follows: 0: No flow control 3: Hardware flow control 4: Software (XON/XOFF) flow control 6: Both hardware and software flow control enable reboot The enable reboot command enables the watchdog timer to reset the system if the timer should expire. By default, the system does not reset if the watchdog timer expires (and the watchdog timer is enabled). enable remote The enable remote command enables re ...

disable wdt, 6-38

Disk drive status LEDs, 4-9 Diskettes, preparing for FSB, 7-15 Display device selecting, 2-8 verifying, 2-8 DPR, 6-3 Dual-port RAM, 6-3 DUART ports, 6-5 E Editing a file, 5-29 EEPROMs, 6-3 eg*0_inet_init environment variable, 3-9 eg*0_mode variable, 5-44 ei*0_inet_init environment variable, 3-9 ei*0_mode variable, 5-44 ei*0_protocols environment variable, 3-10 Emergency runtime image recovery, 6-32 enable wdt, 6-40 Enclosure, 4-4 before opening, 4-2 env command (RMC), 6-19 Environment variables, 5-2, 5-38, 5-40 Environment, monitoring, 6-19 Error ...

The elements of the sample dial string and alert string are shown in Table 6–3. Paging

services vary, so you need to become familiar with the options provided by the paging service you will be using. The RMC supports only numeric messages. n Sets the string to be used by the RMC to dial out when an alert condition occurs. The dial string must include the appropriate modem commands to dial the number. o Sets the alert string, typically the phone number of the modem connected to the remote system. The alert string is appended after the dial string, and the combined string is sent to the mode ...

Configuring Remote Dial-In

Before you can dial in through the RMC modem port or enable the system to call out in response to system alerts, you must configure RMC for remote dial-in. You can use either a VT terminal or a VGA monitor to configure the RMC for remote dial- in: 1. Connect to the RMC using either a VT terminal attached to COM1 or through the VGA monitor. See Figure 6–3 or Figure 6–4 for connections. 2. Initialize the remote dial-in configuration as shown in Example 6–1. 3. Complete one of the following: a. If you use a VT terminal, disconnect it and connect the modem to C ...

Replacing Bottom Drive – Internal Storage Cage

1. Shut down the system and remove the top cover as explained in Section 4.2. 2. Remove the internal storage cage and all cables as explained in Section 4.8. 3. Remove the four screws n from the sides of the bottom drive o and slide the drive from the cage. 4. Slide the new drive into the cage and insert the four screws. 5. Reinstall the storage cage as explained in Section 4.8. 6. Replace the top cover and reassemble the system enclosure as explained in the end of Section 4.2. 7. Turn on system power by pressing the power switch on the operator ...

HP AlphaServer TS15 user guide recommended for: ProLiant DL360 G6, ProLiant ML370, ProLiant DL180se G6 Server, ProLiant ML150 Gen9, ProLiant DL180 Generation 6 (G6).

⚠️ Download Safety

The Server Owner's manual (252 pages) is completely safe to download (last scan date: 08/06/2026).

Related PDF Instructions for HP AlphaServer TS15:

Server Equipment: Frequently Requested

Have some Questions about HP AlphaServer TS15 Device?

Get valuable and actionable advices from other HP AlphaServer TS15 device users. Describe your problem or question, regarding the using of AlphaServer TS15, in as much detail as possible, and other users will be able to answer you.