Greenlee SVC-10 Instruction Manual

File Specifications

Brand: Greenlee
Category: Circuit Tester
Model: SVC-10 (Instruction Manual), prJRXaineFzoc
File Info: Adobe Acrobat PDF (DjVu)
File Size: 0.42 Mb
Pages: 44 pages

Download PDF

Download Greenlee SVC-10 Manual (44 pages)

Read Online:

Read the Greenlee SVC-10 Instruction Manual online using the built-in PDF viewer. This document explains how to operate the device, adjust settings and perform regular maintenance.

Key Pages of Document

SVC-10 • SVC-20

29 Cómo reemplazar la pila 1. Desconecte los cables de prueba del circuito. Apague la unidad que esté utilizando. 2. Empuje con cuidado hacia afuera el compartimiento de la pila insertando un destornillador en la ranura ubicada en uno de los lados de la unidad que esté utilizando. 3. Reemplace la pila (fíjese en la polaridad). 4. Deslice el compartimiento de la pila nuevamente en la unidad que esté utilizando. Antes de abrir la caja, retire del circuito los cables de prueba, y apague la unidad que esté utilizando. De no observarse esta advertencia pueden sufrirse graves ...

Cómo abrir y cerrar estas unidades

No las abra a la fuerza. Estas unidades pueden abrirse y cerrarse sin aplicar fuerza. Si intenta abrirlas a la fuerza puede dañarlas. Para abrir Para cerrar ...

Vérification de la séquence de phase

Dans les systèmes électriques à trois phases, celles-ci sont séparées par un déphasage de 120 degrés. La première est une de référence ; la seconde est décalée de 120 degrés par rapport à la première ; la troisième est décalée de 120 degrés par rapport à la seconde. Vagues de tension triphasées Connexion du capteur L1 Connexion du capteur L2 Affichage L1 / A / R L2 / B / S L3 / C / T L2 / B / S L3 / C / T L1 / A / R L3 / C / T L1 / A / R L2 / B / S Au moins trois conventions servent à identifier les phases : � ...

Important Safety Information

Electric shock hazard: Contact with live circuits can result in severe injury or death. Electric shock hazard: • Do not apply more than the rated voltage between the input terminals, or between any input terminal and earth ground. • Do not contact the test lead tips. Failure to observe these warnings can result in severe injury or death. Electric shock hazard: • Do not use the unit if it is wet or damaged. • Inspect the test leads before use. They must be clean and dry, and the insulation must be in good condition Failure to observe these warnings can res ...

Greenlee SVC-10 user guide recommended for: LT-100, 5708, PG1, PairMapper, AFI-100.

⚠️ Download Safety

The Circuit Tester Instruction manual (44 pages) is completely safe to download (last scan date: 01/03/2026).

Related PDF Instructions for Greenlee SVC-10:

Circuit Tester Equipment: Frequently Requested

Have some Questions about Greenlee SVC-10 Device?

Get valuable and actionable advices from other Greenlee SVC-10 device users. Describe your problem or question, regarding the using of SVC-10, in as much detail as possible, and other users will be able to answer you.