Hussmann E2V Datasheet
Text of the manual
Item Part #
Description
Wiring Item #
FAN ASSEMBLIES AND THERMOSTATS
A.
7W Fan Assembly
(1)
Fan Motor, Evaporator
0058698
Standard (120V, 60Hz)
0439052
Energy Efficient Fan (120V, 60Hz)
0436516
Export (230V, 50 Hz)
0142780
Fan Blade, embossing toward motor
B.
0411744
Standard Non-adjustable
(2)
Defrost Thermostat
C.
0353949
Optional Adjustable
(3)
Refrigeration Thermostat
Item Part #
Description
Wiring Item #
LAMPS AND BALLASTS
D.
0466234
Ballast, Electronic
2 lamps
(4)
D.
0466235
Ballast, Electronic
3 lamps
(4)
D.
0466236
Ballast, Electronic
4 lamps
(4)
E.
Fluorescent Lamp
(5)
Replace with like fixtures
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Note: Changed items have been underlined.
E2V
Data Sheet Set
P/N 0475958
NSF® Certified
October 2005
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
2 of 7
E2V Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Engineering
Plan Views
Dimensions shown as inches and (mm).
01-2004
34 1/2
(876)
8 3/8 (213)
Electrical Service
29 5/8
(752)
Waste Outlet
Front
CL
A
C
D
B
F
E
27 5/8
(702)
30 3/4
(781)
46 1/2
(1181)
Water Seal
E2V
Delicatessen
Precut & Packaged
Produce
4 ft
6 ft
8 ft
12 ft
General
(A) Case Length (without ends or partitions)
48 1/8 (1222)
72 1/8 (1832)
96 1/4 (2445)
144 3/8 (3667)
Maximum O/S dimension back to front (with bumper) 46 1/2 (1181)
46 1/2 (1181)
46 1/2 (1181)
46 1/2 (1181)
Back of case to front of front panel
34 1/2 (876)
34 1/2 (876)
34 1/2 (876)
34 1/2 (876)
Back of case to O/S edge of front skid rail
29 3/8 (746)
29 3/8 (746)
29 3/8 (746)
29 3/8 (746)
Width of skid rail
4 1/2 (114)
4 1/2 (114)
4 1/2 (114)
4 1/2 (114)
RH end of case to outside edge of external support
1 3/8 (34)
1 3/8 (34)
1 3/8 (34)
1 3/8 (34)
Distance between edges of
external support and center support
NA
28 1/2 (724)
40 1/2 (1029)
40 1/2 (1029)
Distance between edges of center supports
NA
NA
NA
44 (1118)
Stub-up area between front skid rail and front panel
5 3/4 (146)
5 3/4 (146)
5 3/4 (146)
5 3/4 (146)
Electrical Service (Electrical Field Wiring connection point)
(B) Length of electrical raceway
18 3/8 (467)
18 3/8 (467)
37 (940)
37 (940)
(C) RH End of case to center of farthest knockout
36 5/8 (930)
60 3/4 (1543)
84 3/4 (2153)
132 3/4 (3372)
Back of case to center of end knockout
29 5/8 (752)
29 5/8 (752)
29 5/8 (752)
29 5/8 (752)
(D) RH End of case to RH end of raceway
27 5/8 (702)
51 5/8 (1311)
57 1/4 (1454)
105 1/8 (2670)
(E) LH End of case to LH end of raceway
2 1/8 (54)
2 1/8 (54)
2 (51)
2 1/4 (57)
Waste Outlet
(F) RH End of case to the center of waste outlet
24 1/4 (616)
24 1/4 (616)
24 1/2 (622)
72 1/4 (1834)
LH End of case to the center of waste outlet
23 7/8 (606)
47 7/8 (1216)
71 3/4 (1822)
72 1/8 (1832)
Back O/S of case to center of waste outlet
27 5/8 (702)
27 5/8 (702)
27 5/8 (702)
27 5/8 (702)
Water Seal
Edge of water seal to center of waste outlet
4 (102)
4 (102)
4 (102)
4 (102)
Outside diameter of the drip pipe
1 1/2 (38)
1 1/2 (38)
1 1/2 (38)
1 1/2 (38)
NOTE: Water seal outlet must clear front skid rail;
water seal rotation in forward direction only due to low base.
Refrigeration Outlet
Back of case to center of refrigeration outlet
30 3/4 (781)
30 3/4 (781)
30 3/4 (781)
30 3/4 (781)
RH end of case to center of refrigeration outlet
8 3/8 (213)
8 3/8 (213)
8 3/8 (213)
8 3/8 (213)
3 of 7
P/N 0475958
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
10 (254)
15 (381)
22 (559)
31 (787)
Refrigeration
Outlet
FAN
C
O
I
L
E2V
52 3/4
(1340)
25 3/8
(645)
4 1/4
(108)
27 5/8
(702)
30 3/4
(781)
34 1/2
(876)
46 1/2
(1181)
18
(457)
26
(660)
23 3/4
(606)
15 3/4 (400)
12
(305)
Impact Elite E2V
Delicatessen
Precut & Packaged Produce
Elite Specialty Merchandiser Multi-deck, up to 3 Display Levels
Dimensions shown as in. & (mm).
NSF Certification
These merchandisers are manufactured to meet ANSI /National
Sanitation Foundation (NSF®) Standard #7 requirements.
See Page 7 for
shelf arrangement.
REFRIGERATION DATA
Note: This data is based on store temperature
and humidity that does not exceed 75 (°F)
and 55% R.H.
E2V
MEAT
DELI
Discharge Air (°F)
25
27
Evaporator (°F)
18
21
Unit Sizing (°F)
16
19
Btu/hr/ft*
Parallel
945
920
Conventional
1030
1000
*For all refrigeration equipment other than
Hussmann, use conventional Btu values.
DEFROST DATA
Frequency (hr)
6
Defrost Water
8 lb/ft/day
(± 15% based on case configuration and
product loading).
OFFTIME
E2V
Temp Term (°F)
48
Failsafe (minutes)
40
ELECTRIC OR GAS
Not Recommended
Standard Defrost Thermostat
Close on rise: close 48°F – open 33°F
CONVENTIONAL CONTROLS
Low Pressure Backup Control CI/CO**
E2V
Meat
Deli
Temp (°F)
11 / 6
14 / 4
Indoor Unit Only, Pressure Defrost
Termination (Temp °F)**
48°F
**Use a Temperature Pressure Chart to
determine PSIG conversions.
PHYSICAL DATA
Drip Pipe (in.)
1 1/2
Liquid Line (in.)
3/8
Suction Line (in.)
7/8
Estimated Charge (lb)***
E2V
4 ft
0.9
6 ft
1.8
8 ft
1.9
12 ft
2.9
***This is an average for all refrigerant types
actual refrigerant charge may vary
by approximately half a pound.
Length (in.) Added to Lineup by Each
End or Insulated Partition
1
4 of 7
E2V Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact Elite E2V
Delicatessen
Precut & Packaged Produce
Electrical Data
4 ft
6 ft
8 ft
12 ft
Number of Fans — 7W
1
2
2
3
Number of Fans — 7W (Export)
1
2
2
3
(Export: 230V 50 hz shown)
Amperes
Watts
Merchandiser
4 ft
6 ft
8 ft
12 ft
4 ft
6 ft
8 ft
12 ft
Fans
Standard (120V 60Hz)
0.50
1.00
1.00
1.50
36
78
78
117
Energy Efficient (120V 60 Hz)
0.26
0.52
0.52
0.78
18
36
36
54
Export (230V 50Hz)
0.28
0.56
0.56
0.84
44
89
89
132
Cycling Anti-sweat Heaters
NA
Minimum Circuit Ampacity
With Standard Fans (120V 60Hz)
0.70
1.20
1.20
1.70
With Energy Efficient Fans (120V 60 Hz)
0.46
0.72
0.72
0.98
With Export Fans (230V 50Hz)
0.48
0.76
0.76
1.04
Maximum Over Current Protection
20
20
20
20
Export (230V 50Hz)
15
15
15
15
Electric Defrost Heaters (208V 1Ph)
NA
Standard Lighting
2 Rows Canopy
0.51
1.01
1.01
1.52
66
122
122
183
Optional Lighting
1 Row Rail Lights
0.51
0.51
0.51
0.76
62
62
62
96
1 Row Ledge Lights
0.51
0.51
0.51
0.76
62
62
62
96
Optional Shelf Lighting
1 Row of Shelves
0.51
0.51
0.51
0.76
62
62
62
96
2 Rows of Shelves
0.51
1.01
1.01
1.52
66
122
122
183
3 Rows of Shelves
0.76
1.53
1.53
2.28
92
184
184
274
5 of 7
P/N 0475958
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Defrost
Termination
Thermostat
Refrigeration
Thermostat
Dark Blue
3
To
Condensing
Unit
}
Light Blue
2
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
= 120V POWER
= 120V NEUTRAL
= Field GROUND
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
Fan Wiring
Offtime Defrost
2 & 3 Fans
120V NEUTRAL
BROWN BAND
120V POWER
Fans
1
BROWN BAND
= Case GROUND
Connector
Connector
G
Connector
Connector
Connector
Connector
Connector
Optional Shelf Harness and Light Circuits for
One Row of Shelves
120 V
Power
B
W
G
B
BL
BL
BL G
G
R
R
BL
BL G
W
BL
Shelf Harness
Shelf Light Circuits
BL
G
R
5
4
W
BL
R
5
BL
R
G
G
R
R
R
G
Shelf Lighting
G
G
R
BL
5
BL
Connector
Connector
B
Optional Lighting: 1 Row Ledge or 1 Row Rail
Light Circuits
Standard Lighting 2 Rows Canopy
WARNING
All components must have mechanical ground, and the merchandiser must be grounded.
= 120V POWER
= 120V NEUTRAL
Grayed components in 12 foot models only.
R = Red Y = Yellow G = Green BL = Blue B = Black W = White
CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS
120V NEUTRAL
ORANGE OR TAN BAND
W
Light
Switch
120V POWER
ORANGE OR TAN
BAND
B
B
W
BL
R
R
BL
BL
4
BL
R
R
BL
BL
4
5
5
5
5
5
5
120V NEUTRAL
ORANGE OR TAN BAND
W
Light
Switch
120V POWER
ORANGE OR TAN
BAND
B
BL
R
R
BL
BL
4
5
5
R
5
R
R
6 of 7
E2V Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
This merchandiser is designed for three
shelves.
This illustration shows recommended
shelf depth and shelf angle for the three
locations.
It is critical to case performance that no
product, shelf or stop extend beyond the
load limit, as shown in this illustration.
This configuration supports the air
curtain and provides optimal case
performance.
Check with Hussmann engineering
before using a different configuration.
Impact Elite E2V
Delicatessen
Precut & Packaged Produce
7 of 7
P/N 0475958