Hussmann E2V Datasheet

Text of the manual

Item Part #

Description Wiring Item # FAN ASSEMBLIES AND THERMOSTATS A. 7W Fan Assembly (1) Fan Motor, Evaporator 0058698 Standard (120V, 60Hz) 0439052 Energy Efficient Fan (120V, 60Hz) 0436516 Export (230V, 50 Hz) 0142780 Fan Blade, embossing toward motor B. 0411744 Standard Non-adjustable (2) Defrost Thermostat C. 0353949 Optional Adjustable (3) Refrigeration Thermostat Item Part # Description Wiring Item # LAMPS AND BALLASTS D. 0466234 Ballast, Electronic 2 lamps (4) D. 0466235 Ballast, Electronic 3 lamps (4) D. 0466236 Ballast, Electronic 4 lamps (4) E. Fluorescent Lamp (5) Replace with like fixtures HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Note: Changed items have been underlined. E2V Data Sheet Set P/N 0475958 NSF® Certified October 2005 We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped.

2 of 7

E2V Data Sheet HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Engineering Plan Views Dimensions shown as inches and (mm). 01-2004 34 1/2 (876) 8 3/8 (213) Electrical Service 29 5/8 (752) Waste Outlet Front CL A C D B F E 27 5/8 (702) 30 3/4 (781) 46 1/2 (1181) Water Seal E2V Delicatessen Precut & Packaged Produce 4 ft 6 ft 8 ft 12 ft General (A) Case Length (without ends or partitions) 48 1/8 (1222) 72 1/8 (1832) 96 1/4 (2445) 144 3/8 (3667) Maximum O/S dimension back to front (with bumper) 46 1/2 (1181) 46 1/2 (1181) 46 1/2 (1181) 46 1/2 (1181) Back of case to front of front panel 34 1/2 (876) 34 1/2 (876) 34 1/2 (876) 34 1/2 (876) Back of case to O/S edge of front skid rail 29 3/8 (746) 29 3/8 (746) 29 3/8 (746) 29 3/8 (746) Width of skid rail 4 1/2 (114) 4 1/2 (114) 4 1/2 (114) 4 1/2 (114) RH end of case to outside edge of external support 1 3/8 (34) 1 3/8 (34) 1 3/8 (34) 1 3/8 (34) Distance between edges of external support and center support NA 28 1/2 (724) 40 1/2 (1029) 40 1/2 (1029) Distance between edges of center supports NA NA NA 44 (1118) Stub-up area between front skid rail and front panel 5 3/4 (146) 5 3/4 (146) 5 3/4 (146) 5 3/4 (146) Electrical Service (Electrical Field Wiring connection point) (B) Length of electrical raceway 18 3/8 (467) 18 3/8 (467) 37 (940) 37 (940) (C) RH End of case to center of farthest knockout 36 5/8 (930) 60 3/4 (1543) 84 3/4 (2153) 132 3/4 (3372) Back of case to center of end knockout 29 5/8 (752) 29 5/8 (752) 29 5/8 (752) 29 5/8 (752) (D) RH End of case to RH end of raceway 27 5/8 (702) 51 5/8 (1311) 57 1/4 (1454) 105 1/8 (2670) (E) LH End of case to LH end of raceway 2 1/8 (54) 2 1/8 (54) 2 (51) 2 1/4 (57) Waste Outlet (F) RH End of case to the center of waste outlet 24 1/4 (616) 24 1/4 (616) 24 1/2 (622) 72 1/4 (1834) LH End of case to the center of waste outlet 23 7/8 (606) 47 7/8 (1216) 71 3/4 (1822) 72 1/8 (1832) Back O/S of case to center of waste outlet 27 5/8 (702) 27 5/8 (702) 27 5/8 (702) 27 5/8 (702) Water Seal Edge of water seal to center of waste outlet 4 (102) 4 (102) 4 (102) 4 (102) Outside diameter of the drip pipe 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) 1 1/2 (38) NOTE: Water seal outlet must clear front skid rail; water seal rotation in forward direction only due to low base. Refrigeration Outlet Back of case to center of refrigeration outlet 30 3/4 (781) 30 3/4 (781) 30 3/4 (781) 30 3/4 (781) RH end of case to center of refrigeration outlet 8 3/8 (213) 8 3/8 (213) 8 3/8 (213) 8 3/8 (213)

3 of 7

P/N 0475958 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 10 (254) 15 (381) 22 (559) 31 (787) Refrigeration Outlet FAN C O I L E2V 52 3/4 (1340) 25 3/8 (645) 4 1/4 (108) 27 5/8 (702) 30 3/4 (781) 34 1/2 (876) 46 1/2 (1181) 18 (457) 26 (660) 23 3/4 (606) 15 3/4 (400) 12 (305) Impact Elite E2V Delicatessen Precut & Packaged Produce Elite Specialty Merchandiser Multi-deck, up to 3 Display Levels Dimensions shown as in. & (mm). NSF Certification These merchandisers are manufactured to meet ANSI /National Sanitation Foundation (NSF®) Standard #7 requirements. See Page 7 for shelf arrangement. REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75 (°F) and 55% R.H. E2V MEAT DELI Discharge Air (°F) 25 27 Evaporator (°F) 18 21 Unit Sizing (°F) 16 19 Btu/hr/ft* Parallel 945 920 Conventional 1030 1000 *For all refrigeration equipment other than Hussmann, use conventional Btu values. DEFROST DATA Frequency (hr) 6 Defrost Water 8 lb/ft/day (± 15% based on case configuration and product loading). OFFTIME E2V Temp Term (°F) 48 Failsafe (minutes) 40 ELECTRIC OR GAS Not Recommended Standard Defrost Thermostat Close on rise: close 48°F – open 33°F CONVENTIONAL CONTROLS Low Pressure Backup Control CI/CO** E2V Meat Deli Temp (°F) 11 / 6 14 / 4 Indoor Unit Only, Pressure Defrost Termination (Temp °F)** 48°F **Use a Temperature Pressure Chart to determine PSIG conversions. PHYSICAL DATA Drip Pipe (in.) 1 1/2 Liquid Line (in.) 3/8 Suction Line (in.) 7/8 Estimated Charge (lb)*** E2V 4 ft 0.9 6 ft 1.8 8 ft 1.9 12 ft 2.9 ***This is an average for all refrigerant types actual refrigerant charge may vary by approximately half a pound. Length (in.) Added to Lineup by Each End or Insulated Partition 1

4 of 7

E2V Data Sheet HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Impact Elite E2V Delicatessen Precut & Packaged Produce Electrical Data 4 ft 6 ft 8 ft 12 ft Number of Fans — 7W 1 2 2 3 Number of Fans — 7W (Export) 1 2 2 3 (Export: 230V 50 hz shown) Amperes Watts Merchandiser 4 ft 6 ft 8 ft 12 ft 4 ft 6 ft 8 ft 12 ft Fans Standard (120V 60Hz) 0.50 1.00 1.00 1.50 36 78 78 117 Energy Efficient (120V 60 Hz) 0.26 0.52 0.52 0.78 18 36 36 54 Export (230V 50Hz) 0.28 0.56 0.56 0.84 44 89 89 132 Cycling Anti-sweat Heaters NA Minimum Circuit Ampacity With Standard Fans (120V 60Hz) 0.70 1.20 1.20 1.70 With Energy Efficient Fans (120V 60 Hz) 0.46 0.72 0.72 0.98 With Export Fans (230V 50Hz) 0.48 0.76 0.76 1.04 Maximum Over Current Protection 20 20 20 20 Export (230V 50Hz) 15 15 15 15 Electric Defrost Heaters (208V 1Ph) NA Standard Lighting 2 Rows Canopy 0.51 1.01 1.01 1.52 66 122 122 183 Optional Lighting 1 Row Rail Lights 0.51 0.51 0.51 0.76 62 62 62 96 1 Row Ledge Lights 0.51 0.51 0.51 0.76 62 62 62 96 Optional Shelf Lighting 1 Row of Shelves 0.51 0.51 0.51 0.76 62 62 62 96 2 Rows of Shelves 0.51 1.01 1.01 1.52 66 122 122 183 3 Rows of Shelves 0.76 1.53 1.53 2.28 92 184 184 274

5 of 7

P/N 0475958 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Defrost Termination Thermostat Refrigeration Thermostat Dark Blue 3 To Condensing Unit } Light Blue 2 Grayed components in 12 foot models only. R = Red Y = Yellow G = Green BL = Blue B = Black W = White = 120V POWER = 120V NEUTRAL = Field GROUND WARNING All components must have mechanical ground, and the merchandiser must be grounded. CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 & 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND = Case GROUND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light Circuits BL G R 5 4 W BL R 5 BL R G G R R R G Shelf Lighting G G R BL 5 BL Connector Connector B

Optional Lighting: 1 Row Ledge or 1 Row Rail

Light Circuits Standard Lighting 2 Rows Canopy WARNING All components must have mechanical ground, and the merchandiser must be grounded. = 120V POWER = 120V NEUTRAL Grayed components in 12 foot models only. R = Red Y = Yellow G = Green BL = Blue B = Black W = White CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL R R BL BL 4 BL R R BL BL 4 5 5 5 5 5 5 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 4 5 5 R 5 R R 6 of 7 E2V Data Sheet HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

This merchandiser is designed for three

shelves. This illustration shows recommended shelf depth and shelf angle for the three locations. It is critical to case performance that no product, shelf or stop extend beyond the load limit, as shown in this illustration. This configuration supports the air curtain and provides optimal case performance. Check with Hussmann engineering before using a different configuration. Impact Elite E2V Delicatessen Precut & Packaged Produce 7 of 7 P/N 0475958 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.