Icom IC-80AD Instruction Manual

Specifications

Brand: Icom
Category: Transceiver
Model: IC-80AD (Instruction Manual)
File Type: PDF
File Size: —
Pages: 188

Read Online

Read the Icom IC-80AD Instruction Manual online using the built-in PDF viewer.

Text of the manual

This device complies with Part 15 of the FCC Rules. Operation is

subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. WARNING: MODIFICATION OF THIS DEVICE TO RECEIVE CEL- LULAR RADIOTELEPHONE SERVICE SIGNALS IS PROHIBITED UNDER FCC RULES AND FEDERAL LAW. INSTRUCTION MANUAL i80AD VHF/UHF DIGITAL TRANSCEIVER

Thank you for purchasing this fine Icom product. We under-

stand you have a choice of many different radios in the mar- ket place. Many hours of research and development went into the design of your IC-80AD, following Icom’s philosophy of “technology first.” The IC-80AD VHF/UHF DIGITAL TRANSCEIVER is designed with Icom’s superior technology and craftsmanship combining tra- ditional analog technologies with the new digital technology, Digital Smart Technologies for Amateur Radio (D-STAR), for a balanced package. With proper care, this product should provide you with years of trouble-free operation. We want to take a couple of mo- ments of your time to thank you for making your IC-80AD your radio of choice, and hope you agree with Icom’s philoso- phy of “technology first.” EXPLICIT DEFINITIONS WORD DEFINITION R DANGER! Personal death, serious injury or an ex- plosion may occur. R WARNING! Personal injury, fire hazard or electric shock may occur. CAUTION Equipment damage may occur. NOTE Recommended for optimum use. No risk of personal injury, fire or electric shock. FEATURES M DV mode (Digital voice + Low-speed data communication) operation-ready – Text message and call sign exchange – Transmitting position data with a GPS re- ceiver M GPS receiver connectable – Optional HM-189GPS is required M DR (D-STAR Repeater) mode and repeater list allow you to operate a D-STAR repeater simply M Splash-resistant construction (IPX4*) * Only when the supplied battery pack (or optional battery case), antenna and jack cover are at- tached. IMPORTANT READ ALL INSTRUCTIONS carefully and completely before using the transceiver. SAVE THIS INSTRUCTION MANUAL— This instruction manual contains important operating instructions for the IC-80AD.

RWARNING RF EXPOSURE! This device emits

Radio Frequency (RF) energy. Caution should be observed when operating this device. If you have any questions regard- ing RF exposure and safety standards please refer to the Federal Communications Commission Office of Engineering and Technology’s report on Evaluating Compliance with FCC Guidelines for Human Radio Frequency Electromagnetic Fields (OET Bulletin 65) RWARNING! NEVER hold the transceiver so that the antenna is very close to, or touching exposed parts of the body, especially the face or eyes, while transmitting. The transceiver will perform best if the microphone is 5 to 10 cm (2 to 4 inches) away from the lips and the transceiver is verti- cal. RWARNING! NEVER operate the transceiver with an earphone, headphones or other audio accessories at high volume levels. Hearing experts advise against continuous high volume operation. If you experience a ringing in your ears, reduce the volume level or discontinue use. RWARNING! NEVER operate the transceiver while driving a vehicle. Safe driving requires your full attention— anything less may result in an accident. NEVER connect the transceiver to a power source of more than 16 V DC. This will ruin the transceiver. NEVER connect the transceiver to a power source using reverse polarity. This will ruin the transceiver. DO NOT operate the transceiver near unshielded electri- cal blasting caps or in an explosive atmosphere. DO NOT push the PTT unless you actually intend to trans- mit. BE CAREFUL! The transceiver will become hot when op- erating it continuously for long periods. DO NOT use or place the transceiver in direct sunlight or in areas with temperatures below –20°C (–4˚F) or above +60°C (+140˚F). Place the unit in a secure place to avoid inadvertent use by children. DO NOT use harsh solvents such as benzene or alcohol to clean the transceiver, because they can damage the trans- ceiver’s surfaces. PRECAUTIONS

• FOR CLASS B UNINTENTIONAL RADIATORS:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential instal- lation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that inter- ference will not occur in a particular installation. If this equip- ment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the inter- ference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and re- ceiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. For U.S.A. only CAUTION: Changes or modifications to this device, not expressly approved by Icom Inc., could void your authority to operate this device under FCC regulations. PRECAUTIONS KEEP away from heavy rain, and never immerse the IC-80AD in the water. The transceiver meets IPX4* require- ments for splash resistance. However, once the transceiver has been dropped, splash resistance cannot be guaranteed because of possible damage to the transceiver’s case or wa- terproof seal. * Only when the supplied battery pack (or optional battery case), antenna and jack cover are attached. NEVER operate or touch the transceiver with wet hands. This may result in an electric shock or may damage the trans- ceiver. Even when the transceiver power is OFF, a slight current still flows in the circuits. Remove the battery pack or batteries from the transceiver when not using it for a long time. Other- wise, the installed battery pack or batteries will become ex- hausted, and will need to be recharged or replaced. • Important notes when using GPS receiver Please do not use the HM-189GPS close to the transceiver’s antenna. The transmit signal may cause GPS receiver mal- function.

Icom, Icom Inc. and the Icom logo are registered trademarks of Icom

Incorporated (Japan) in the United States, the United Kingdom, Ger- many, France, Spain, Russia and/or other countries. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Microsoft, Windows and Windows Vista are registered trademarks of Microsoft Corporation in the United States and/or other countries. SUPPLIED ACCESSORIES The following accessories are supplied with the transceiver. q Hand strap ····································································· 1 w Antenna ·········································································· 1 e Battery pack (BP-217) ···················································· 1 r Belt clip ···········································································1 t Battery charger (BC-167SA/SC/SV)* ····························· 1 * The BC-167SA, BC-167SC and BC-167SV have different shapes. t e q r w

FOREWORD ····················································································· i

EXPLICIT DEFINITIONS ··································································· i FEATURES ························································································ i IMPORTANT ······················································································ i PRECAUTIONS ············································································ii, iii FCC INFORMATION ······································································· iii SUPPLIED ACCESSORIES ···························································· iv TABLE OF CONTENTS ······························································v–vii 1 ACCESSORY ATTACHMENT ·················································1–2 N Antenna ···················································································1 N Belt clip ····················································································1 N Hand strap ···············································································2 N Battery pack ·············································································2 2 PANEL DESCRIPTION ···························································3–9 N Front, top and side panels ·······················································3 N Function display ·······································································8 3 BATTERY CHARGING ·······················································10–15 N Caution ··················································································10 N Regular charging ···································································12 N Rapid charging·······································································13 N Optional battery case ·····························································14 N Battery information ································································14 N External DC power operation ·················································15 4 BASIC OPERATION ···························································16–28 N Power ON ··············································································16 N Setting audio volume ·····························································16 N Setting squelch level ······························································17 N Monitor function ·····································································17 N Mode selection·······································································18 N [DIAL] function assignment ····················································20 N Operating band selection ·······················································20 N Setting a tuning step ······························································22 N Setting a frequency ································································22 N Lock function ··········································································24 N Receiving ···············································································24 N Operating mode selection ······················································25 N Attenuator function ·································································25 N Transmitting ············································································26 N Transmit power selection ·······················································27 N TV channel operation ·····························································27 5 REPEATER AND DUPLEX OPERATIONS ························29–33 N Repeater operation ································································29 N Duplex operation ····································································31 N Auto repeater function ···························································32 N 1750 Hz tone ·········································································33 6 DV MODE PROGRAMMING ···············································34–46 N About the D-STAR system ·····················································34 N Call sign programming ···························································36 N Repeater list ··········································································39 N Repeater list programming ····················································40 N Changing a repeater list·························································45 N Clearing a repeater list ··························································46 TABLE OF CONTENTS

7 DV MODE OPERATION ······················································47–76

N Digital mode operation ···························································47 N Current call sign setting ·························································47 N Receiving a D-STAR repeater ················································48 N Received call sign ··································································49 N Copying the call sign ······························································51 N DR (D-STAR Repeater) mode operation ·······························53 N Calling CQ ·············································································54 N Calling a specific station ························································56 N Simplex operation in VFO ······················································60 N Repeater operation in VFO ····················································62 N Message operation ································································68 N Automatic reply function ························································70 N EMR communication ······························································71 N Break-in communication ························································72 N Low-speed data communication ············································74 N Other function for DV mode operation ···································76 8 GPS/GPS-A OPERATION ··················································77–90 N GPS operation ·······································································77 N GPS-A operation ····································································90 9 MEMORY/CALL CHANNELS ·············································91–101 N General description································································91 N Selecting a memory channel ·················································92 N Selecting a call channel ·························································93 N Memory channel programming ··············································94 N Memory bank setting ·····························································95 N Memory bank selection ··························································96 N Programming memory/bank/scan name ································97 N Selecting memory/bank name indication ·······························98 N Copying memory/call contents···············································99 N Memory clearing ··································································100 N Erasing/transferring bank contents ······································101 10 SCAN OPERATION ························································102–110 N Scan types ···········································································102 N Full/band/programmed scan ···············································104 N Scan edges programming ····················································105 N Memory scan ······································································106 N Memory bank scan ······························································107 N Skip channel/frequency setting ············································108 N Scan resume condition ························································110 11 PRIORITY WATCH ··························································111–114 N Priority watch types ·····························································111 N Priority watch operation ·······················································112 12 MENU SCREEN OPERATION ········································115–142 N General ············································································115 N MENU screen indication and arrangement ··························116 N Items list ············································································117 N DUP/TONE items (DUP.T) ···················································119 N Scan items (SCAN) ·····························································121 N Set mode items (SET) ·························································124  Function set mode items (FUNC) ····································124  Display set mode items (DISP) ·······································129  Sounds set mode items (SOUNDS) ································130 N DV set mode items (DV SET) ··············································132 N GPS mode items (GPS)·······················································136 TABLE OF CONTENTS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

TABLE OF CONTENTS

13 OTHER FUNCTIONS ······················································143–159 N Programming a DTMF code ················································143 N Transmitting a DTMF code ···················································144 N Clearing a DTMF memory ···················································145 N Confirming a DTMF memory ···············································146 N Setting DTMF transfer speed ···············································146 N Tone frequency and DTCS code ··········································147 N Digital code and digital call sign setting ······························148 N Tone/DTCS squelch ·····························································150 N Digital squelch ·····································································151 N Pocket beep function ···························································151 N DTCS polarity setting ···························································152 N Tone scan·············································································152 N Beep tones···········································································153 N Dial speed acceleration ·······················································153 N Key lock effect ······································································154 N Weather channel operation ··················································154 N Power save ··········································································156 N Auto power OFF···································································156 N Auto power ON ····································································156 N Time-out timer ······································································157 N PTT lock ···············································································157 N Display backlighting ·····························································157 N LCD contrast ········································································157 N Cloning function ···································································158 N Resetting··············································································159 14 TROUBLESHOOTING ·····························································160 15 SPECIFICATIONS ···························································161–162 16 OPTIONS ········································································163–166 N Optional HM-75A REMOTE CONTROL SPEAKER MICROPHONE ·····164 N Optional HM-189GPS GPS SPEAKER MICROPHONE ···············166 INDEX ·················································································167–173

Insert the supplied antenna into the antenna connector and

screw down the antenna as shown below. Jack cover NEVER carry the transceiver by holding the antenna. KEEP the jack cover attached when jack is not in use to pro- tect the connector from dust and moisture.  For your information Third-party antennas may increase transceiver performance. An optional AD-92SMA ANTENNA CONNECTOR ADAPTER is available to connect an antenna that has a BNC connector. N Belt clip Supplied screws CAUTION: USE the supplied screws only. Using screws longer than specified could damage the transceiver.

N Hand strap

To facilitate carrying the transceiver, slide the hand strap through the loop on the top of the belt clip as illustrated below. Handstrap N Battery pack Attach the Li-Ion battery pack (BP-217) or battery case (BP- 216) as illustrated below. • Charge the Li-Ion battery pack before use. (pgs. 12, 13) q w Battery pack/Battery case Latch

N Front, top and side panels

Speaker Keypad Internal microphone Function display q y u t r w e i o !1 !0 q ANTENNA CONNECTOR (p. 1) Connects the supplied antenna. • An optional AD-92SMA adapter (p. 163) is available for connecting an antenna with a BNC connector. w PTT SWITCH [PTT] (p. 26) Push and hold to transmit, release to receive. e TX/RX INDICATOR [TX/RX] (pgs. 24, 26) Lights green while receiving a signal or when the squelch is open; lights red while transmitting. r SQUELCH KEY [SQL] (p. 17) ± Push and hold to open the squelch temporarily and monitor the operating frequency. ± While pushing and holding this key, rotate [DIAL] to ad- just the squelch level. t MENU • LOCK KEY [MENU ] ± Push to enter menu screen indication ON and OFF. (p. 115) • Pushing [V/MHz] also exits from menu screen. ± Push and hold for 1 sec. to toggle the lock function ON and OFF. (p. 24) y POWER KEY [PWR] Push and hold for 1 sec. to turn the transceiver power ON and OFF. (p. 16)

u VOLUME CONTROL KEY []/[]

± Adjust audio volume level. (p. 16) ± [] enters or sends the DTMF code ‘D.’ (pgs. 143–145) The function of tuning control and volume control can be traded. See page 20 for details. i CONTROL DIAL [DIAL] ± Rotate to tune the operating frequency. (p. 22) ± During memory mode, rotate to select the memory channel. (pgs. 18, 92) ± While scanning, changes the scanning direction. (pgs. 53, 104, 106, 107) ± While pushing and holding [SQL], sets the squelch level. (p. 17) ± After pushing [BAND] during memory mode operation, selects the programmed bank. (p. 96) ± During menu screen operation, rotate to select the set items or values. (p. 115) The function of tuning control and volume control can be traded. See page 20 for details. o EXTERNAL SPEAKER/MICROPHONE JACK [SP/MIC] Connect a cloning cable, optional speaker microphone or headset, if desired. See page 163 for a list of available options. Be sure to turn power OFF before connectiong/discon- necting optional equipment to/from the [SP/MIC] jack.

!0 EXTERNAL DC IN JACK [DC IN]

± Connects the supplied wall charger, BC-167SA/SC/SV, to charge the attached battery pack. (p. 12) ± Connect an external DC power supply through the op- tional CP-12L, CP-19R or OPC-254L for external DC operation. (p. 15) !1 DATA JACK [DATA] (pgs. 74, 77, 158) Connects a PC through the optional data communication cable, OPC-1529R, for low-speed data communication in DV mode or cloning operation. The jack and cable are also used to connect a GPS receiver. D KEYPAD ± Push to input numeral for frequency input, memory chan- nel selection, etc. ± Push to enter or send the DTMF code. (pgs. 143–145) 1 • VOLUME/DIAL KEY [1] • [V<=>D](1) ± Numeral input and DTMF code: ‘1’ ± Push and hold for 1 sec. to exchange the assigned functions between [DIAL] and []/[]. (p. 20) 2 • TUNING STEP KEY [2] • [TS](2) ± Numeral input and DTMF code: ‘2’ ± Push and hold for 1 sec. to enter tuning step set mode. (p. 22) ± During menu screen operation or select memory write mode, push to select the set items or values. (p. 115) 3 • OUTPUT POWER KEY [3] • [LOW](3) ± Numeral input and DTMF code: ‘3’ ± Push and hold for 1 sec. to select the output power. (p. 27) • Selects the transmit output power from high, mid, low and S-low. • While pushing and holding this key, [DIAL] rotation se- lects the output power. 4 • DUPLEX KEY [4] • [DUP](4) ± Numeral input and DTMF code: ‘4’ ± Push and hold for 1 sec. to select minus duplex, plus duplex, and simplex operation. (p. 31) • “DUP–” (minus duplex), “DUP” (plus duplex) and no indication (simplex) appear in order. • While pushing and holding this key, [DIAL] rotation se- lects the duplex operation. ± During menu screen operation, push to select the upper layer. (p. 115)

5 • SKIP KEY [5] • [SKIP](5)

± Numeral input and DTMF code: ‘5’ ± Push and hold to turn the frequency skip function ON and OFF in VFO mode, or set the memory channel as the following skip channel in memory mode in order. (pgs. 102, 108, 109) • “SKIP” appears when memory skip, “PSKIP” appears when frequency skip and no indication appears when non skip channel is set. • While pushing and holding this key, [DIAL] rotation se- lects the skip condition. ± During menu screen operation, push to enter or exit to/from the selected set items, etc. (p. 115) 6 • MEMORY NAME KEY [6] • [M.N](6) ± Numeral input and DTMF code: ‘6’ ± Push and hold for 1 sec. to turn the memory or bank name indication ON and OFF. (p. 98) • While pushing and holding this key, [DIAL] rotation se- lects the memory or bank indication. ± During menu screen operation, push to select the lower layer. (p. 115) 7 • TONE/DIGITAL SQUELCH KEY [7] • [TONE](7)/[DSQ](7) ± Numeral input and DTMF code: ‘7’ ± During FM/FM-N mode operation, push and hold for 1 sec. to select repeater tone, tone squelch, tone squelch reverse, DTCS squelch, DTCS squelch reverse and no tone operation in se- quence. (p. 150) • Pocket beep function is available for tone squelch and DTCS squelch. (p. 151) ± During DV mode operation, push and hold for 1 sec. to select digital call sign squelch, digital code squelch and no squelch operation in sequence. (p. 151) • Pocket beep function is available. (p. 151) 8 • RX CALL SIGN SET KEY [8] • [RXCS](8) ± Numeral input and DTMF code: ‘8’ ± During DV mode operation, push and hold for 1 sec. to set the received call signs (station and repeaters) to current call sign. (p. 50) ± During menu screen operation or select memory write mode, push to select the set items or values. (p. 115) 9 • TONE SCAN/CALL SIGN KEY [9] • [T.SCAN](9)/[CS](9) ± Numeral input and DTMF code: ‘9’ ± During FM/FM-N mode operation, push and hold for 1 sec. to start tone scan function. (p. 152) ± During DV mode operation (including DR mode operation), push and hold for 1 sec. to enter the current call sign mode. (pgs. 48, 59)

0 • DTMF KEY [0] • [DTMF](0)

± Numeral input and DTMF code: ‘0’ ± Push and hold for 1 sec. to select DTMF memory mode. (p. 143) VFO/MHz • SCAN KEY [V/MHz] • [SCAN](V/MHz) ± DTMF code: ‘A’ ± Push to select VFO mode. (p. 18) ± During VFO mode operation, push to select 1 MHz and 10 MHz tuning steps. (p. 22) ± Push and hold for 1 sec. to enter scan type selec- tion mode. (pgs. 104, 106, 107) • Push again to start the scan. ± Cancels numeral key input. (p. 23) ± During menu screen operation or select memory write mode, push to return to previous operating condition. (pgs. 94, 115) MEMORY/CALL • SELECT MEMORY WRITE KEY [M/CALL] • [S.MW](M/CALL) ± DTMF code: ‘B’ ± Push to select memory mode, call channel, TV channel and weather channel. (pgs. 18, 19, 27, 92, 93, 154) ± Push and hold for 1 sec. to enter select memory write mode. (p. 94) DR (D-STAR REPEATER) KEY [DR] ± DTMF code: ‘C’ ± Push to select DR mode. (pgs. 19, 53, 54, 56) ± During DR mode operation, push to enter the ac- cess repeater selection. VOLUME CONTROL (UP) KEY [] ± DTMF code ‘D.’ ± Adjust audio volume level. (p. 16) BAND • MODE KEY [BAND] • [MODE](BAND) ± DTMF code: ‘1 (indication: E)’ ± During VFO mode operation, push to select an operating frequency band. (pgs. 20, 21) ± During memory mode operation, push to enter memory bank group selection. (p. 96) ± Push and hold for 1 sec. to select the operating mode. (p. 25) . • UR KEY [.] • [UR](.) ± DTMF code ‘# (indication: F).’ ± Inputs MHz digit for frequency input. ± During DV mode operation (including DR mode operation), push and hold for 1 sec. to enter the station call sign selection mode. (pgs. 60, 61) • Rotate [DIAL] to select the call sign. During other than DV mode operation, pushing and holding this key enters the station call sign selection mode with changing the operating mode to DV mode.

N Function display

!2 !3 y i o !0 !1 u !4 !5 !6 q w e r t q BATTERY INDICATOR (pgs. 12, 14) ± “ ” (battery indicators) appear when the battery pack is attached. ± “ ” appears when the battery cells/pack must be changed/charged. ± The indicators show “ ,” “ ” and “ ” in sequence while charging the attached battery pack. w KEY LOCK INDICATOR (p. 24) Appears when the key lock function is activated. e DUPLEX INDICATOR (p. 31) “ DUP” appears when plus duplex, “DUP–” appears when minus duplex is selected. r TONE INDICATOR • While operating in FM/FM-N mode; ± “ T” appears while the subaudible tone encoder is in use. (p. 29) ± “ T SQL” appears while the tone squelch function is in use. (p. 150) ± “ T SQL-R” appears while the reverse tone squelch func- tion is in use. (p. 150) ± “ DTCS” appears while the DTCS squelch function is in use. (p. 150) ± “ DTCS -R” appears while the reverse DTCS squelch function is in use. (p. 150) ± “ S” appears with the “T SQL” or “DTCS” indicator while the pocket beep function (with CTCSS or DTCS) is in use. (p. 151) • While operating in DV mode; ± “ D SQL” appears while the digital call sign squelch func- tion is in use. (p. 151) ± “ CSQL” appears while the digital code squelch function is in use. (p. 151) ± “ S” appears with the “D SQL” or “CSQL” indicator while the pocket beep function (with digital call sign or digital code squelch) is in use. (p. 151) 8 2 PANEL DESCRIPTION

t SKIP INDICATOR

± “ SKIP” appears when the selected memory channel is set as a skip channel. (pgs. 108, 109) ± “ PSKIP” appears when the displayed frequency is set as a skip frequency in memory mode. (pgs. 108, 109) ± “ PSKIP” appears during the frequency skip scan func- tion is ON in VFO mode. (p. 102) y DR (D-STAR REPEATER) INDICATOR (pgs. 19, 53, 54, 56) Appears when DR mode is selected. u MEMORY INDICATOR (pgs. 18, 92) Appears when memory mode is selected. i MEMORY CHANNEL NUMBER INDICATOR ± Shows the selected memory channel number. (pgs. 18, 92) ± “C0” or “C1” appears when the call channel is selected. (pgs. 19, 93) ± “TV” appears when the TV channel is selected. (pgs. 19, 27) o GPS INDICATOR Appears while GPS function is in use. • GPS indicator can be turned OFF in GPS.SET mode. (p. 137) ± Stays ON when GPS receiver is connected and a valid position data is received. ± Blinks when an invalid position data is received. !0 VOLUME INDICATOR (p. 20) Appears when [DIAL] is assigned volume control, then []/[] are assigned tuning controls. !1 PRIORITY WATCH INDICATOR (pgs. 112–114) Appears when priority watch is in use. !2 S/RF METER ± Shows the relative signal strength while receiving sig- nals. (p. 24) ± Shows the output power level while transmitting. (pgs. 26, 27) !3 POWER INDICATOR (p. 27) ± “ L” appears when low power is selected. ± “ SL” appears when S-low power is selected. ± “ M” appears when middle power is selected. ± No indicator appears when high power is selected. !4 ATTENUATOR INDICATOR (p. 25) Appears when the RF attenuator is in use. !5 OPERATING MODE INDICATOR (p. 25) Shows the selected operating mode. • DV, FM, FM-N, WFM and AM are available, depending on op- erating band. • “DVG” or “DV A” appears when GPS transmission or GPS-A transmission is selected in DV mode. (p. 138) !6 FREQUENCY READOUT ± Displays a variety of information, such as operating fre- quency, set mode contents. • The decimal point blinks during scan. ± During memory mode operation, the programmed memory or memory bank name is displayed.

• R DANGER! Use and charge only specified Icom battery

packs with Icom radios. Only Icom battery packs are tested and approved for use with Icom radios. Using third-party or counterfeit battery packs may cause smoke, fire, or cause the battery to burst. D Battery caution • R DANGER! DO NOT hammer or otherwise impact the bat- tery. Do not use the battery if it has been severely impacted or dropped, or if the battery has been subjected to heavy pressure. Battery damage may not be visible on the outside of the case. Even if the surface of the battery does not show cracks or any other damage, the cells inside the battery may rupture or catch fire. • R DANGER! NEVER use or leave battery pack in areas with temperatures above +60˚C (+140˚F). High tempera- ture buildup in the battery, such as could occur near fires or stoves, inside a sun heated car, or in direct sunlight may cause the battery to rupture or catch fire. Excessive tem- peratures may also degrade battery performance or shorten battery life. • R DANGER! DO NOT expose the battery to rain, snow, seawater, or any other liquids. Do not charge or use a wet battery. If the battery gets wet, be sure to wipe it dry before using. • R DANGER! NEVER incinerate a used battery pack since internal battery gas may cause it to rupture, or may cause an explosion. • R DANGER! NEVER solder the battery terminals, or NEVER modify the battery pack. This may cause heat gen- eration, and the battery may burst, emit smoke or catch fire. • R DANGER! Use the battery only with the transceiver for which it is specified. Never use a battery with any other equipment, or for any purpose that is not specified in this instruction manual. • R DANGER! If fluid from inside the battery gets in your eyes, blindness can result. Rinse your eyes with clean water, without rubbing them, and see a doctor immediately. • WARNING! Immediately stop using the battery if it emits an abnormal odor, heats up, or is discolored or deformed. If any of these conditions occur, contact your Icom dealer or distributor. • WARNING! Immediately wash, using clean water, any part of the body that comes into contact with fluid from inside the battery. Misuse of Lithium-Ion batteries may result in the following hazards: smoke, fire, or the battery may rupture. Misuse can also cause damage to the battery or degradation of battery performance.

• WARNING! NEVER put the battery in a microwave oven,

high-pressure container, or in an induction heating cooker. This could cause a fire, overheating, or cause the battery to rupture. • CAUTION: Always use the battery within the specified tem- perature range, –20˚C to +60˚C (–4˚F to +140˚F). Using the battery out of its specified temperature range will reduce the battery’s performance and battery life. • CAUTION: Shorter battery life could occur if the battery is left fully charged, completely discharged, or in an exces- sive temperature environment (above +50˚C; +122˚F) for an extended period of time. If the battery must be left unused for a long time, it must be detached from the radio after dis- charging. You may use the battery until the battery indicator shows half-capacity, then keep it safely in a cool dry place at the following temperature range: –20˚C (–4˚F) to +50˚C (+122˚F) (within a month). –20˚C (–4˚F) to +35˚C (+95˚F) (within three months). –20˚C (–4˚F) to +20˚C (+68˚F) (within a year). D Charging caution • R DANGER! NEVER charge the battery pack in areas with extremely high temperatures, such as near fires or stoves, inside a sun-heated vehicle, or in direct sunlight. In such environments, the safety/protection circuit in the battery will activate, causing the battery to stop charging. • WARNING! DO NOT charge or leave the battery in the bat- tery charger beyond the specified time for charging. If the battery is not completely charged by the specified time, stop charging and remove the battery from the battery charger. Continuing to charge the battery beyond the specified time limit may cause a fire, overheating, or the battery may rup- ture. • WARNING! NEVER insert the transceiver (battery attached to the transceiver) into the charger if it is wet or soiled. This could corrode the battery charger terminals or damage the charger. The charger is not waterproof. • CAUTION: DO NOT charge the battery outside of the speci- fied temperature range: 0˚C to +35˚C (+32˚F to +95˚F). Icom recommends charging the battery at +25˚C (+77˚F). The battery may heat up or rupture if charged out of the specified temperature range. Additionally, battery perfor- mance or battery life may be reduced.

N Regular charging

Prior to using the transceiver for the first time, the battery pack must be fully charged for optimum life and operation. D Battery indicators The indicators show “ ,” “ ” and “ ” in sequence and “CHARGE” appears while charging (when the transceiver’s power is OFF). The indicators and “CHARGE” disappear when the battery pack is completely charged. D Charging note • Be sure to turn the transceiver power OFF. Otherwise the battery pack will not be charged completely or will take much longer to charge. • External DC power operation becomes possible when using an optional CP-12L, CP-19R or OPC-254L. The attached battery pack is also charged simultaneously, except during transmit (see p. 15 for more details). • The external DC power supply voltage must be between 10–16 V to charge the battery pack and for operation when using an optional OPC-254L. • BC-167 • CP-12L (Optional) • OPC-254L (Optional) to AC outlet to cigarette lighter socket (12 V DC) to 12 V DC (power supply) White: + Black: _ Transceiver to [DC IN] Turn power OFF while charging the battery pack. The BC-167SA, BC-167SC and BC-167SV have different shapes. • Charging time period: Approx. 6 hours BP-217 • CP-19R (Optional)

N Rapid charging

The optional BC-139 provides rapid charging of the battery pack. D Charging note • Be sure to turn the transceiver power OFF. Detach the battery pack from the transceiver then charge the battery pack by itself, or charge the battery with regular charging when the transceiver power cannot be turned OFF. Otherwise the battery pack will not be charged (charging indicator on the BC-139 blinks orange about 10 sec. after the battery pack is installed in BC-139). • The desktop charger, BC-139, can only charge BP-217 bat- tery packs. Other types of rechargeable battery, Ni-Cd or Ni-MH cannot be charged. • If the charging indicator blinks orange, there may be a problem with the battery pack or charger. If this occurs, try charging the battery pack alone, without the transceiver, or try using the standard (non-rapid) charger. Contact your dealer if you have problems charging a new battery pack. • The optional CP-12L and OPC-254L can be used instead of the supplied AC adapter. Connect one of these to the [DC 13.5V] jack in this case. • Charging period: approx. 2.5 hours (with BP-217) A Transceiver (with battery pack) Turn power OFF. Check the orientation. Battery pack to AC outlet BC-139 (optional) Desktop charger to [AC ADAPTER] Adapter (supplied with BC-139) Charging indicator Charging : Orange Finished : Green Charging terminal BC-123 (supplied with BC-139) NOTE: If the charging indicator blinks orange for 10 sec. or more with the battery pack installed in the transceiver, try charging the BP-217 alone. You can also try charging the BP-217 alone using the standard (non-rapid) battery charger.

N Optional battery case

± Install 2 × LR6 (AA) size alkaline batteries into the optional BP-216 BATTERY CASE. • Be sure to observe the cor- rect polarity. A built-in step-up converter in the BP-216 increases the voltage to 5 V DC. Approx. 100 mW of output power is possible with the BP-216 operation. Also, no transmit output power selec- tion (TX inhibit) is available. Keep battery contacts clean. It’s a good idea to clean bat- tery terminals once a week. D Battery information The batteries may seem to have low capacity when used in low temperatures such as –10°C (+14°F) or below. Keep the batteries warm in this case. D Battery replacement When the batteries become exhausted, the function display may blink or have a lower contrast. In this cases, replace all batteries with new, same brand, alkaline batteries. N Battery information D Battery life The transceiver operates with the BP-217 Li-ion as follows. When operating in DV mode, operating time may be short- ened by one-half hour. • VHF band : Approx. 6.5 hours • UHF band : Approx. 6.0 hours (Tx: Rx: Stand-by=1: 1: 8) Even when the transceiver power is OFF, a small current still flows in the radio. Remove the battery pack or case from the transceiver when not using it for a long time. Oth- erwise, the battery pack or installed batteries will become exhausted. The battery protection function sets transceiver to Low power (0.5 W) automatically when temperature is 0°C (+32°F) or below. In this case, transmit power selections (Hi/Mid) are also disable. D Battery indicator The battery indicator, “ ,” appears only when the BP-217 Li-ion is attached to the transceiver. The battery indicator does not appear when turning power ON after charging is completed without disconnecting the battery charger or external DC power. Indication Battery condition The battery has ample capacity. The battery is nearing exhaustion. Charging is neces- sary.

N External DC power operation

An optional cigarette lighter cable (CP-12L or CP-19R; for 12 V cigarette lighter socket) or external DC power cable (OPC-254L) can be used for external power operation. D Operating note • Power supply voltage must be between 10.0–16.0 V DC. NEVER CONNECT OVER 16 V DC directly into the [DC IN] jack of the transceiver. • BE SURE to use CP-12L, CP-19R or OPC-254L when connecting a regulated 12 V DC power supply. Use an external DC-DC converter to connect the transceiver through optional CP-12L, CP-19R or OPC-254L to a 24 V DC power source. • The voltage of the external power supply must be within 10–16 V DC when using either CP-12L, CP-19R or OPC- 254L, otherwise, use the battery pack. • Disconnect the power cables from the transceiver when not using it. Otherwise, the vehicle battery will become ex- hausted. • The power save function is deactivated automatically dur- ing external DC power operation. Transceiver BP-217 • CP-12L (Optional) • CP-19R (Optional) • OPC-254L (Optional) to cigarette lighter socket (12 V DC) to 12 V DC (power supply) White: + Black: _ to [DC IN] NOTE: Up to 5 W (approx.) of maximum output power is available when using external DC power. However, when the supplied voltage exceeds 14 V, the built-in protection circuit activates to reduce the transmit output power to 2.5 W (approx.).

N Power ON

± Push and hold [PWR] for 1 sec. to turn power ON. • Push and hold [PWR] for 1 sec. to turn power OFF. Opening message is selectable in DISP set mode (SET). MENU ¶SET ¶DISP ¶OPN.MSG (p. 130) N Setting audio volume ± Push [] or [] several times to adjust the audio level. • If squelch is closed, push and hold [SQL] while setting the audio level. • The display shows the volume level while setting. Minimum setting (no audio) Maximum setting Volume level indicator Beep level is adjustable in SOUNDS set mode (SET). MENU ¶SET ¶SOUNDS ¶BEEPLV (p. 130)

N Setting squelch level

The squelch circuit mutes the received audio signal depend- ing on the signal strength. The transceiver has 9 squelch lev- els, a continuously open setting and an automatic squelch setting. ± While pushing and holding [SQL], rotate [DIAL] to select the squelch level. • “ LEVEL1” is loose squelch (for weak signals) and “LEVEL9” is tight squelch (for strong signals). • “ AUTO” indicates automatic level adjustment by a noise pulse counting system. • “OPEN” indicates continuously open setting. (This selection is not available in DV mode.) [DIAL] Maximum level Automatic squelch N Monitor function This function is used to listen to weak signals without disturb- ing the squelch setting or to open the squelch manually even when mute functions such as the tone squelch are in use. ± Push and hold [SQL] to monitor the operating frequency. • The 1st segment of the S-meter blinks. The 1st segment blinks The [SQL] key can be set to ‘sticky’ operation in FUNC set mode (SET). See page 125 for details. MENU ¶SET ¶FUNC ¶MONI (p. 125)

N Mode selection

D VFO mode VFO mode is used to set the desired frequency. ± Push [V/MHz] to select VFO mode. • VFO mode indication What is VFO? VFO is an abbreviation of Variable Frequency Oscillator. Fre- quencies for both transmitting and receiving are generated and controlled by the VFO. D Memory mode Memory mode is used for operation on memory channels which store programmed frequencies. q Push [M/CALL] to select memory mode. • “ ” appears when memory mode is selected. • Push [M/CALL] several times to select call channels/TV* chan- nels/Weather† channels. Memory/Call/TV*/Weather† channels can be selected in sequence. • Memory mode indication Appear w Rotate [DIAL] to select the desired memory channel. • Only programmed memory channels can be selected. • Enter the memory channel directly to select the desired memory channel. (p. 92) • See p. 94 for memory programming details. * Appears only when TV channels are programmed via the CS-80/880 (free download software). † Available for the U.S.A. version only. Set the attenuator function ON (p. 25) if the received signal is blocked by another radio transmitter when using a third party high-gain antenna.

D Call/TV*/Weather† channels

Call channels are used for quick recall of most-often used frequencies. * Appears only when TV channels are programmed via the CS-80/880 (free download software). † Available for the U.S.A. version only. q Push [M/CALL] several times to select call channels/TV channels/Weather channels. • Memory/Call/TV/Weather channels can be selected in se- quence. w Rotate [DIAL] to select the desired channel. • Call channel indication • TV channel indication • Weather channel indication TV reception is available for analog TV broadcasting only, but it is not available for digital TV bradcasting. D DR (D-STAR Repeater) mode DR (D-STAR Repeater) mode is used for D-STAR repeater operation. In this mode, you can select the pre-programmed repeaters and UR call sign easily by using [DIAL]. D-STAR is an abbreviation for Digital Smart Technologies for Amateur Radio. q Push [DR] to select DR mode. • “ ” appears when DR mode is selected. • DR mode indication Appear w Rotate [DIAL] to select the desired access repeater. • While rotating [DIAL], S/RF-meter indicates group number. • Only programmed access repeaters in RPT-L menu can be se- lected. See p. 40 for RPT-L (repeter lists) programming details. MENU ¶RPT-L ¶ADD-L (p. 40) 19 4 BASIC OPERATION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

N [DIAL] function assignment

The [DIAL] control can be used as an audio volume con- trol instead of []/[] keys to suit your preference. However, when [DIAL] functions as an audio volume, []/[] keys function as tuning controls. ± Push and hold [V<=>D](1) for 1 sec. to toggle the dial func- tion between tuning dial and audio volume. Appears • The following functions are switched between [DIAL] and []/[]. [DIAL] []/[] Frequency, Memory channel, Squelch level, Scanning direction Audio volume set N Operating band selection The transceiver can receive the AM broadcast, HF bands, 50 MHz, FM broadcast, VHF air, 144 MHz, 300 MHz, 400 MHz or 800 MHz* bands. ± In VFO mode, push [BAND] several times to select the desired frequency band. • If VFO mode is not selected, such as a memory channel/call channel/TV channel/Weather channel, push [V/MHz] to select VFO mode first, then push [BAND] to select the desired band. Available frequency bands are different depending on ver- sion. See the specification for details. (p. 161) * Some frequency ranges are blocked for the U.S.A. ver- sion by regulation. • 144 MHz band • 400 MHz band 20 4 BASIC OPERATION

• Available frequency bands

AM broadcast band HF band 50 MHz band 800 MHz band 400 MHz band FM broadcast band VHF air band 144 MHz band 300 MHz band : Push Initial frequencies shown differ according to version. 21 4 BASIC OPERATION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

N Setting a tuning step

The tuning step can be selected for each frequency band. The following tuning steps are available for the IC-80AD. • 5.0 kHz* • 6.25 kHz* • 8.33 kHz† • 9.0 kHz‡ • 10.0 kHz • 12.5 kHz • 15.0 kHz* • 20.0 kHz • 25.0 kHz • 30.0 kHz • 50.0 kHz • 100.0 kHz • 125.0 kHz • 200.0 kHz * Appears for bands below the 600 MHz only. † Appears for the VHF air band only. ‡ Appears for the AM broadcast band only. D Tuning step selection q Push [V/MHz] to select VFO mode, if necessary. w Push [BAND] to select the desired frequency band. e Push and hold [TS](2) for 1 sec. to enter tuning step set mode. • While pushing and holding [TS](2), rotating [DIAL] is also se- lectable tuning step. r Rotate [DIAL] to select the desired tuning step. t Push [TS](2) (or [V/MHz]) to return to VFO mode. [DIAL] 5 kHz tuning step N Setting a frequency D Using the dial q Push [V/MHz] to select VFO mode, if necessary. w Select the desired frequency band with [BAND]. e Rotate [DIAL] to select the desired frequency. • The frequency changes according to the preset tuning steps. See the previous content to set the tuning step. • When VFO mode is selected, push [V/MHz] then rotate [DIAL] to change the frequency in 1 MHz steps, or push [V/MHz] again then rotate [DIAL] to change the frequency in 10 MHz steps. Push [V/MHz] again to cancel it.) [DIAL] [DIAL] changes the frequency according to the selected tuning step. After pushing [V/MHz] on VFO mode, [DIAL] changes the frequency in 1 MHz/10 MHz steps.

Depending on the

tuning step setting, it may not be possible to input a 1 kHz digit. In this case, enter “0” as 1 kHz digit, then ro- tate [DIAL] to set the desired frequency. • Entering 145.580 MHz • Entering 79.300 MHz • Editing to 684 kHz • Changing 100 kHz and below Editing 145.580 MHz to 145.640 MHz Push to cancel numeral key input. D Using the keypad The frequency can be directly set via numeric keys. • If a frequency outside the frequency range is en- tered, the previously displayed frequency is auto- matically recalled after entering last digit. q Push [V/MHz] to select VFO mode, if nec- essary. w Enter the desired frequency via the keypad.

N Lock function

To prevent accidental frequency changes and unnecessary function access, use the lock function. ± Push and hold [ ](MENU) for 1 sec. to turn the lock func- tion ON and OFF. • “ ” appears while the lock function is activated. • [PWR], []/[], [SQL], [PTT] and [ ](MENU) are operable while the lock function is activated. • The squelch control and volume control can be used while the lock function is in use with default setting. Either or both the squelch control and volume control can also be locked in set mode. MENU ¶SET ¶FUNC ¶LOCK (p. 127) Appears N Receiving Make sure a charged battery pack (BP-217) or brand new alkaline batteries (BP-216) are installed (pgs. 2, 14). q Push and hold [PWR] for 1 sec. to turn power ON. w Push [] or [] to set the desired audio level. (p. 16) • The frequency display shows the volume level while setting. e Set the receiving frequency. (p. 23) r Set the squelch level. (p. 17) • While pushing and holding [SQL], rotate [DIAL]. • The first click of [DIAL] indicates the current squelch level. • “ LEVEL 1” is loose squelch (for weak signals) and “LEVEL 9” is tight squelch (for strong signals). • “ AUTO” indicates automatic level adjustment by a noise pulse counting system. • Push and hold [SQL] to open the squelch manually. t When a signal is received: • Squelch opens and audio is output. • The S/RF-meter shows the relative signal strength level. q [PWR] e Set frequency r Set squelch level w Set audio level e Select band r Push for setting the squelch (Push to monitor)

N Operating mode selection

Operating modes are determined by the modulation of the radio signals. The transceiver has total 5 operating modes (FM, FM-N, WFM, AM and DV modes). The mode selection is stored independently for each band and memory channel. Typically, AM mode is used for the AM broadcast stations (0.495–1.620 MHz) and air band (118–136.995 MHz), and WFM is used for FM broadcast stations (76–107.9 MHz). WFM mode cannot be selected above 810 MHz for U.S.A. ver- sion. ± Push and hold [MODE](BAND) for 1 sec. several times to select the desired operating mode. • While pushing and holding [MODE](BAND), rotate [DIAL] is also available to select operating mode. [DIAL] FM FM N WFM AM DV + [DIAL] N Attenuator function The attenuator prevents distortion of a desired signal by very strong signals near the desired frequency or when very strong electric fields, such as from a broadcasting station, are present at your location. The attenuation is about 10 dB. q Enter “ATT” in FUNC set mode (SET). MENU ¶ SET ¶ FUNC ¶ ATT (p. 124) (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) w Push [](2) or [](8) to select “ON” or “OFF.” e Push [ ](5) (or [◁](4)) to return to set mode, and push [V/MHz] to return to frequency indication. • “ATT” appears on the function display when “ON” is selected. Appears

CAUTION: Transmitting without an antenna will damage the

transceiver. NOTE: To prevent interference, push and hold [SQL] to listen on the channel before transmitting. Tx/Rx Microphone indicator q Set the operating frequency. (p. 23) • Transmission is available on the 144 MHz/440 MHz amateur bands only. • Select output power if desired. See next page for details. w Push and hold [PTT] to transmit. • Tx/Rx indicator lights red. • S/RF meter shows the output power level. e Speak into the microphone using your normal voice level. • DO NOT hold the transceiver too close to your mouth or speak too loudly. This may distort your speech. r Release [PTT] to return to receive. WARNING! NEVER continuously transmit for long periods of time. When the transceiver is used for continuous prolonged transmission at high power, the transceiver radiates heat to protect itself from overheating and transceiver’s chassis will become hot. This may cause a burn. DO NOT operate the transceiver in a situation that will obstruct heat dissipation, especially if the transceiver is operated with an external power supply. Heat dissipation may be affected, and it may cause a burn, warp the casing or damage the transceiver. NOTE: Transmit power set 2.5 W (MID) automatically when the transceiver radiates heat. CONNECT the rated range voltage when using external power supply.

N Transmit power selection

The transceiver has four output power levels to suit your op- erating requirements. S-Low output power during short-range communications may reduce the possibility of interference to other stations and will conserve battery power. ± Push and hold [LOW](3) for 1 sec. to toggle the trans- mit output power between High (5W*), Mid (2.5 W*), Low (0.5 W*) and S-Low (0.1 W*). *approx. • While pushing and holding [LOW](3), rotate [DIAL] is also avail- able to select transmit power. [DIAL] Appears ONLY S-Low power operation is available while using BP-216. S-Low power transmission Low power transmission Mid. power transmission High power transmission N TV channel operation TV channel operation is available only when TV channels are programmed using the CS-80/880 (free download software). (p. 163) D TV channel receiving q Push [M/CALL] several times to select TV channels. • “ TV” and channel number appear. w Rotate [DIAL] to select the desired channel. • While pushing and holding [BAND], rotating [DIAL] selects the all channels including skip channel. [DIAL] TV mode indication Channel indication TV reception is available for analog TV broadcasting only, but it is not available for digital TV bradcasting. 27 4 BASIC OPERATION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

D Skip channel setting

Unwanted channels can be skipped for rapid selection, etc. q Push [M/CALL] several times to select TV channels. • “TV” and channel number appear. w Rotate [DIAL] to select the channel to be skipped. • To clear the skip setting, rotate [DIAL] while pushing and holding [BAND] to select a skip channel. • While pushing and holding [SKIP](5), rotating [DIAL] also selects a skip channel. e Push and hold [SKIP](5) for 1 sec. to toggle the skip setting ON and OFF. • “SKIP” appears when the channel is set as skip channel. [DIAL] Appears D Automatic TV channel programming TV channels can be programmed automatically. q Push [M/CALL] several times to select TV channels. • “ TV” and channel number appear. w Push and hold [SCAN](V/MHz) for 1 sec. to start TV channel programming. • The programming will automatically stop after scanning all channels. 28 4 BASIC OPERATION

REPEATER AND DUPLEX OPERATIONS

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 N Repeater operation When using a repeater, the transmit frequency is shifted from the receive frequency by the offset frequency (p. 119). This is called duplex operation. It is convenient to program repeater information into memory channels (p. 94). Station A Station B Repeater 145.300 MHz 144.700 MHz 144.700 MHz 145.300 MHz Uplink Downlink (transmitting freq.) (receiving freq.) q Set the receive frequency (repeater output frequency). w Set the shift direction of the transmit frequency. (DUP– or DUP; see p. 31 for details.) • When the auto repeater function is in use (U.S.A. and Korean versions only), this selection and step e are not necessary. (p. 32) “DUP–”or “DUP” appears T e Push and hold [TONE](7) for 1 sec. to activate the subaudible tone encoder, according to re- peater requirements. • “T” appears. Refer to p. 119 for tone frequency settings. r Push and hold [PTT] to transmit. • The displayed frequency automati- cally changes to the transmit fre- quency (repeater input frequency). • If “OFF” appears, check the off- set frequency or shift direction. (p. 31) While receiving While transmitting t Release [PTT] to receive. y Push and hold [SQL] to check whether the other station’s transmit signal can be directly received or not. U.S.A. and Korean versions: Auto repeater function uses standard values of the re- peater tone frequency and offset frequency.

REPEATER AND DUPLEX OPERATIONS

D Checking the repeater input signal The transceiver can check whether the other station’s trans- mit signal can be received directly or not, by listening on the repeater input frequency. ± Push and hold [SQL] to check whether the other station’s transmit signal can be received directly or not. • When the other station’s signal can be directly received, move to a non-repeater frequency to use simplex. (duplex OFF) Indication while receiving Receives –0.6 MHz shift frequency Blinks while pushing and holding [SQL] Push and hold D Off band indication If the transmit frequency is out of the amateur band, the off band indication, “OFF,” appears on the display when [PTT] is pushed. Check the offset frequency or duplex direction in this case. (p. 31) U.S.A. and Korean versions: Auto repeater function uses standard values of the offset frequency.  CONVENIENT! Tone scan function: When you don’t know the subaudible tone used for a repeater, the tone scan is convenient for de- tecting the tone frequency. ± Push and hold [T.SCAN](9) for 1 sec. to start the tone scan. See p. 152 for more information.

REPEATER AND DUPLEX OPERATIONS

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 N Duplex operation D Setting offset frequency q Enter “OFFSET” in DUP.T menu. MENU ¶ DUP.T ¶ OFFSET (p. 119) (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) w Push []/[] (or rotate [DIAL]) to set the offset fre- quency. e Push [ ](5) to return to DUP.T menu, and then push [MENU ] to return to frequency indication. 0.6 MHz offset No offset frequency Offset frequency setting D Setting duplex direction ± Push and hold [DUP](4) for 1 sec. to select “DUP–” (nega- tive offset) or “DUP” (positive offset). • “DUP–” or “DUP” indicates the transmit frequency for minus shift or plus shift, respectively. • When offset frequency is 0.6 MHz –Duplex example Receiving Transmitting +Duplex example Receiving Transmitting U.S.A. and Korean versions: Auto repeater function has priority over the manual duplex setting. If the transmit frequency changes after setting, the auto repeater function may have changed the duplex setting.

REPEATER AND DUPLEX OPERATIONS

N Auto repeater function The U.S.A. and Korean versions automatically use standard repeater settings (duplex ON/OFF, duplex direction, tone encoder ON/OFF) when the operating frequency falls within or outside of the general repeater output frequency range. The offset and repeater tone frequencies are not changed by the auto repeater function. Reset these frequencies, if necessary. D Frequency range and offset direction • U.S.A. version • Korean version FREQUENCY RANGE SHIFT DIRECTION 439.000–440.000 MHz “DUP–” appears q Enter “AUTORP” in FUNC set mode (SET). MENU ¶ SET ¶ FUNC ¶ AUTORP (p. 126) (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) w Push [](2) or [](8) to select the auto repeater setting. U.S.A. version: • “RPT1” : Activates duplex only. (default) • “RPT2” : Activates duplex and tone. • “OFF” : Auto repeater function is turned OFF. Korean version: • “ON” : Activates duplex and tone. (default) • “OFF” : Auto repeater function is turned OFF. e Push [ ](5) to return to FUNC set mode, and then push [MENU ] to return to frequency indication. Auto repeater setting U.S.A. version Korean version FREQUENCY RANGE SHIFT DIRECTION 147.000–147.395 MHz “DUP” appears 442.000–444.995 MHz “DUP” appears 447.000–449.995 MHz “DUP–” appears 145.200–145.495 MHz 146.610–146.995 MHz “DUP–” appears U.S.A./KOREAN versions only

REPEATER AND DUPLEX OPERATIONS

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 N 1750 Hz tone To access some European repeaters, the transceiver must transmit a 1750 Hz tone burst. For such European repeaters, perform the following. • This tone can be use as a ‘Call signal’ in countries out of Europe. q Push and hold [DTMF.M](0) for 1 sec. to select DTMF memory. w Push [](8) several times (or rotate [DIAL] counter-clock- wise) until “T-CALL” appears. e Push [ ](5) to set. r Push [V/MHz] to exit DTMF memory. t Set the receive frequency (repeater output frequency). y Set the shift direction of the transmit frequency. (–DUP or +DUP; see p. 31 for details.) u While pushing [PTT], push [SQL] to transmit a 1750 Hz tone burst signal. • If “OFF” appears, check the offset frequency or shift direction. (p. 31) • The displayed frequency automatically changes to the transmit frequency (repeater input frequency). i Push and hold [PTT] to transmit. o Release [PTT] to receive. !0 Push and hold [SQL] to check whether the other station’s transmit signal can be received directly or not, by listening on the repeater input frequency.

DV MODE PROGRAMMING

6 N About the D-STAR system In the D-STAR (Digital Smart Technologies for Amateur Radio) system, repeater linking via a 10 GHz backbone and/ or internet gateway provides you with much wider coverage range during digital voice mode operation. • D-STAR system outline Station A Station C Station D Repeater A Repeater D 440 MHz 440 MHz Repeater C 10 GHz Zone Zone Area Station B Repeater B 10 GHz 440 MHz 440 MHz Internet network Internet network In traditional repeater operation, stations that are communi- cating must both be in the repeater's operating area. However, D-STAR repeaters can be linked via a 10 GHz backbone, as shown in the illustration at left. Using D-STAR, stations A and B can communicate even though they are in widely separated repeater operating areas. Furthermore, D-STAR repeaters can be linkled through an internet gateway, which can extend the communication range dramatically. For example, when station B uses the internet gateway connection, it can communicate with station C even though they are thousands of miles apart! By using the gate- way connection, long distance communication is possible using 144 or 440 MHz digital voice! In the D-STAR system, an independent repeater’s operating area is called an Area and a group that of linked repeaters via a 10 GHz backbone is called a Zone. About time-out timer function The IC-80AD has a time-out timer function for digital re- peater operation. The timer limits a continuous transmis- sion to approx. 10 min. Warning beeps will sound approx. 30 sec. before time-out and then again immediately before time-out.

DV MODE PROGRAMMING

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Area 1 Zone A Repeater 1 Area 2 Repeater 2 Area 3 Repeater 3 Area 4 Repeater 4 Zone B Area 7 Repeater 6 Area 6 Repeater 7 Area 8 Repeater 8 Area 5 Repeater 5 Internet Network Internet Network (Gateway) (Gateway) Area: The Area is the communication range that is covered by a single repeater. The repeater is called an area repeater in the D-STAR system. Zone: The Zone is composed of several areas, that are linked by a 10 GHz microwave link. The areas 1 to 4 and 5 to 8 make up a zone in the example above. Link repeater: The microwave (10 GHz) link repeater provides to linking with another repeater site (Area) for zone construction. Gateway repeater: Gateway repeaters provide communications between different zones via the internet. Repeaters 3 and 6 are gateway repeaters in the example above. D System description

DV MODE PROGRAMMING

N Call sign programming Four types of current call sign memory are available; “MY” (my call sign=your own call sign) “UR” (your call sign=other sta- tion call sign) “RPT1” (access repeater call sign) and “RPT2” (link repeater call sign). Each call sign can be programmed with up to 8 characters. In addition, "MY" can store up to 6 call signs, and "UR" can store up to 60 call signs in the call sign memory. Up to 300 repeater call signs can be stored in the repeater list. D Your own call sign programming Your own call sign must be programmed for both digital voice and low-speed data communications (including GPS trans- mission). q Enter “MY” in call sign screen. MENU ¶ CALL-S ¶ MY (Push [MENU ]), (push [](2)/[](8), then push [ ](5).) • MY call sign screen is displayed. w Push [](2) or [](8) to select the desired call sign mem- ory, “MY1” to “MY6.” e Push [](6) to enter call sign programming mode. • The 1st digit blinks. r Push [](2) or [](8) to select the desired character or code. • Push [](6) to move the cursor right; push [◁](4) to move the cursor left. t Repeat the step r to enter your own call sign. • Up to an 8 digit of call sign can be set. • If an unwanted character is entered, push [](6) or [◁](4) to select the character, then push [CLR](1) to erase the selected character, or push and hold [CLR](1) for 1 sec. to erase all char- acters following the cursor. • To program a note (up to 4 characters, for operating radio type, area, etc.), go to step y, otherwise go to step i. y Push [](6) several times to set the cursor beside “/” indi- cation.

DV MODE PROGRAMMING

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 u Repeat step r (at previous page) to program the desired 4 character note. i Push [ ](5) to store the programmed call sign with note and return to call sign screen. o Push [MENU ] to return to frequency indication. D Station call sign programming Station call sign must be programmed to call a specific sta- tion as well as for repeater operation in both digital voice and low-speed data communications. q Enter “UR” in call sign screen. MENU ¶ CALL-S ¶ UR (Push [MENU ]), (push [](2)/[](8), then push [ ](5).) • UR call sign screen is displayed. w Push [](2) or [](8) to select the desired call sign mem- ory, “U01” to “U60.” e Push [](6) to enter call sign programming mode. • The 1st digit blinks. r Push [](2) or [](8) to select the desired character or code. • Push [](6) or [◁](4) to move the cursor right or left, respectively.

DV MODE PROGRAMMING

t Repeat the step r to enter the desired station call sign. • Up to an 8 digit call sign can be set. • If an unwanted character is entered, push [](6) or [◁](4) to select the character, then push [CLR](1) to erase the selected character, or push and hold [CLR](1) for 1 sec. to erase all char- acters following the cursor. y Push [ ](5) to store the programmed call sign and return to UR call sign screen. u Push [MENU ] to return to frequency indication.  For your information The IC-80AD has a call sign edit record function. When editing a call sign stored in a call sign memory (or reg- ular memory/call channel), the default setting is to store the edited call sign into a blank channel automatically. (When all call sign memories are already programmed, the edited call sign will overwrite the selected channels call sign.) The programmed call sign can be over-written when the set- ting of “EDIT R” (Edit record) is set to OFF or SEL. (p. 134) However, you must manually over-write a reprogrammed call sign in regular memory/call channels (temporary operation without over-writing is possible). D Current repeater call sign programming “RPT1” or “RPT2” can store current call sign only, and re- peater call signs must be stored in the repeater list (p. 39). q Enter “RPT1” or “RPT2” in call sign screen. MENU ¶ CALL-S ¶ RPT1 or RPT2 (Push [MENU ]), (push [](2)/[](8), then push [ ](5).) • RPT1/RPT2 call sign screen is displayed. w Push [](6) to enter call sign programming mode. • The 1st digit blinks. e Push [](2) or [](8) to select the desired character or code. • Push [](6) or [◁](4) to move the cursor right or left, respectively. r Repeat the step e to enter the desired repeater call sign. • Up to an 8 digit call sign can be set. • If an unwanted character is entered, push [](6) or [◁](4) to select the character, then push [CLR](1) to erase the selected character, or push and hold [CLR](1) for 1 sec. to erase all char- acters following the cursor. t Push [ ](5) to store the programmed call sign and returns to call sign screen. y Push [MENU ] to return to frequency indication.

DV MODE PROGRAMMING

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 N Repeater list The IC-80AD can store up to 300 repeater call signs. The repeater list also stores the repeater name and access re- peater setting, etc. The outline of repeater list is follows: q Selection for new repeater program or changing a list w Selection for a programmed repeater lists e Repeater programming (Repeater name, Call sign, Gateway repeater call sign, Repeater group, etc.) r Access repeater programming (Down link frequency, Duplex direction, Offset frequency) D Repeater list contents The following information can be programmed into repeater lists:  R-NAME (Repeater name) (pgs. 40, 44)  CALL-S (Repeater call sign) (pgs. 40, 44)  GW CAL (Gateway repeater’s call sign) (pgs. 41, 45)  GROUP (Repeater group) (p. 41)  R1 USE (RPT1 use) (p. 42) When R1 USE is selected YES, following contents appear.  FREQ (Repeater output frequency) (p. 42)  DUP (Duplex direction) (p. 43)  OFF SET (Offset frequency) (p. 43) NOTE: Repeater lists can be erased by static electricity, elec- tric transients, etc. In addition, they can be erased by mal- function and during repairs. Therefore, we recommend that memory data be written down or be saved to a PC using the CS-80/880 CLONING SOFTWARE (free download). RPT-L ADD-L EDIT-L NO YES YES NO YES NO FREQ DUP OFF SET R-NAME R1 USE CALL S GW CAL GROUP ADD W R-NAME Rpeater 1 Rpeater 5 FREQ DUP OFF SET NO YES ADD W OVR W CLEAR R1 USE CALL S GW CAL GROUP q w e r

DV MODE PROGRAMMING

N Repeater list programming D New repeater list programming q Enter “ADD-L” in RPT-L menu. MENU ¶ RPT-L ¶ ADD-L (Push [MENU ]), (push [](2)/[](8), then push [ ](5).) • “R-NAME” appears. Repeater name programming (R-NAME) w Push [ ](5) to enter the repeater name programming state. See p. 44 for repeater name programming details. • Repeater name programming screen is displayed. e Program the repeater name, then push [ ](5) to exit the state. • Push [](2)/[](8) to select the desired character, number, symbol or space. • Push [](6)/[◁](4) to move the cursor right or left, respectively. r Push [](2) or [](8) to select the next content (repeater call sign programming). Repeater call sign programming (CALL S) t Push [ ](5) to enter the repeater call sign programming state. See p. 44 for repeater call sign programming de- tails. • Repeater call sign programming screen is displayed. y Program the repeater call sign, then push [ ](5) to exit the state. • Push [](2)/[](8) to select the desired character, number, symbol (‘/’only) or space. • Push [](6)/[◁](4) to move the cursor right or left, respectively. u Push [](2) or [](8) to select the next content (gateway repeater call sign programming).  CONVENIENT! After you program the repeater call sign, you can skip the other programming and store the list. ± Push and hold [S.MW](M/CALL) for 1 sec. to enter mem- ory write state, then push [ ](5) to store the list.

DV MODE PROGRAMMING

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Gateway repeater call sign programming (GW CAL) i Push [ ](5) to enter the gateway repeater call sign pro- gramming state. See p. 45 for gateway repeater call sign programming details. • Gateway repeater call sign programming screen is displayed. • Programmed repeater call sign is displayed and the 8th digit is automatically added or replaced to “G.” o When the programmed repeater has gateway capability, push [ ](5) to exit gateway repeater setting and skip to !2. Or when the programmed repeater has a different repeater for gateway communication, follow the next step !0. • When the repeater does not have a gateway repeater, follow the next step !0, too. !0 Program the other gateway repeater call sign, then push [ ](5) to exit the state. • Push [](2)/[](8) to select the desired character, number, symbol (‘/’only) or space. • Push [](6)/[◁](4) to move the cursor right or left, respectively. • Up to an 8 digit call sign can be set, but 8th digit must be set to “G.” • When the repeater does not have a gateway repeater, but has several link repeaters, in the same zone, assign a common name to all repeaters. (up to 7 digits). In this case, you must set the 8th digit to “ ”(blank). !1 Push [](2) or [](8) to select the next content (repeater group programming). Repeater group programming (GROUP) The IC-80AD has a total of 10 groups (0–9). You can assign and organize up 300 of repeater lists in the groups. Group selection is helpful for quick recall of the desired repeater. !2 Push [ ](5) to enter the repeater group programming state. • Repeater group programming screen is displayed. • Selected group number appears and group indicator blinks. !3 Push [](2) or [](8) to select the desired repeater group. • Selected group number appears and group indicator blinks. !4 Push [ ](5) to set the repeater group and exit the state. !5 Push [](2) or [](8) to select the next content (access repeater setting).

DV MODE PROGRAMMING

Access repeater setting (R1 USE) The programmed repeater lists are assigned to use for the access repeater (RPT1) or no in DR mode. To use for RPT1, repeater frequency, duplex direction and offset frequency must be programmed. !6 Push [ ](5) to enter the access repeater programming state. • Access repeater programming screen is displayed. !7 Push [](2) or [](8) to select “YES” or “NO.” • When “NO” is selected, the repeater cannot be selected as the access repeater (RPT1) in DR mode. • When “YES” is selected, the repeater can be selected as the access repeater (RPT1) in DR mode. !8 Push [ ](5) to exit the state. ± When “NO” is selected at step !7, skip to step #1. ± When “YES” is selected at step !7, push [](2) or [](8) to select the access repeater (RPT1) programming. Follow the next step !9 to program the repeater. Frequency programming (FREQ) This content appears when R1 USE is selected YES. !9 Push [ ](5) to enter the frequency programming state. • Frequency programming screen is displayed. @0 Push [](2) or [](8) to select the frequency band. • The selected number blinks at 1st digit. • Push [](6) to move the cursor right; push [◁](4) to move the cursor left. • Push and hold [CLR](1) for 1 sec. to clear the displayed fre- quency. @1 Repeat step @0 until the repeater frequency is set. @2 Push [ ](5) to set the frequency and exit the state. @3 Push [](2) or [](8) to select the next content (duplex direction programming).

DV MODE PROGRAMMING

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Duplex direction setting (DUP) This content appears when R1 USE is selected YES. @4 Push [ ](5) to enter the duplex direction setting state. • Duplex direction setting screen is displayed. @5 Push [](2) or [](8) to select the duplex direction. @6 Push [ ](5) to set the duplex direction and exit the state. @7 Push [](2) or [](8) to select the next content (offset frequency programming). Offset frequency programming (OFF SET) This content appears when R1 USE is selected YES. @8 Push [ ](5) to enter the offset frequency programming state. • Offset frequency programming screen is displayed. @9 Push [](2) or [](8) to select the offset frequency. • The selected number blinks. • Push [](6) to move the cursor right; push [◁](4) to move the cursor left. • Push and hold [CLR](1) for 1 sec. to clear the displayed fre- quency. #0 Push [ ](5) to set the offset frequency and exit the state. Storing the repeater list (ADD W) #1 Push [](2) or [](8) to select the store operation. #2 Push [ ](5) to enter storing state. • “ADD W OK?” appears. #3 Push [ ](5) again to store the list.

DV MODE PROGRAMMING

 Repeater name programming (R-NAME) q Push [ ](5) to enter the repeater name programming state. • Repeater name programming screen is displayed. • The 1st digit blinks. w Push [](2) or [](8) to select the desired character, num- ber, symbol or space. • The selected character blinks. • Push [](6) to move the cursor right; push [◁](4) to move the cursor left. • Push [CLR](1) to erase the selected character, or push and hold [CLR](1) for 1 sec. to erase all characters following the cursor. e Repeat step w until the desired repeater name is pro- grammed. • Up to an 8 digit name can be set. r Push [ ](5) to program the repeater name and exit the state.  Repeater call sign programming (CALL S) q Push [ ](5) to enter the repeater call sign programming state. • Repeater call sign programming screen is displayed. • The 1st digit blinks. w Push [](2) or [](8) to select the desired character, num- ber or symbol (‘/’ only). • The selected character blinks. • Push [](6) to move the cursor right; push [◁](4) to move the cursor left. • Push [CLR](1) to erase the selected character, or push and hold [CLR](1) for 1 sec. to erase all characters following the cursor. e Repeat step w until the desired repeater call sign is pro- grammed. • Up to an 8 digit call sign can be set. r Push [ ](5) to program the repeater call sign and exit the state.

DV MODE PROGRAMMING

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19  Gateway repeater call sign programming (GW CALL) q Push [ ](5) to enter the gateway repeater call sign pro- gramming. • Gateway repeater call sign programming screen is displayed. • Programmed repeater call sign is displayed, then the 1st char- acter blinks. • The 8th digit is automatically added or replaced to “G.” w Push [](2) or [](8) to select the desired character, num- ber, symbol (‘/’ only) or space. • The selected character blinks. • Push [](6) to move the cursor right; push [◁](4) to move the cursor left. • Push [CLR](1) to erase the selected character, or push and hold [CLR](1) for 1 sec. to erase all characters following the cursor. e Repeat step w until the desired repeater call sign is pro- grammed. • Up to an 8 digit call sign can be set, but 8th digit must be set to “G.” r Push [ ](5) to program the gateway repeater call sign and exit the state. N Changing a repeater list You can edit the contents of a repeater list to correct errors or added information. q Enter “EDIT-L” in RPT-L menu. MENU ¶ RPT-L ¶ EDIT-L (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • Programmed repeater name appears. SKIP indicator SKIP indicator shows the selected repeater can not be used as an access repeater (RPT1) in DR mode as follow reasons. • “R1 USE” is set to “NO” • Either “FREQ” (frequency) or “DUP” (duplex direction) has not been programmed Push and hold for 1 sec. to select SKIP indicator ON or OFF when both of “FREQ” and “DUP” have been programmed. w Push and hold [BAND] for 1 sec. to enter group selection, rotate [DIAL] to select the desired group (0–9), then push [BAND]. e Push [](2) or [](8) to select the desired repeater list to be changed.

DV MODE PROGRAMMING

r Push [ ](5) to enter the list. t Push [](2) or [](8) to select the content to be changed, then push [ ](5) to enter the content and reprogram the content (see pages 40–43 for new repeater list program- ming details). y After programming is finished, push [](2) or [](8) to select “ADD W” or “OVR W,” then push [ ](5). When “ADD W” is selected; • “ADD W OK?” appears. When “OVR W” is selected; • “OVR W OK?” appears. y Push [ ](5) again to store the list. N Clearing a repeater list Contents of programmed list can be cleared (erased). q Enter “EDIT-L” in RPT-L menu. MENU ¶ RPT-L ¶ EDIT-L (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • Programmed repeater name appears. w Push [](2) or [](8) to select the desired repeater list to be erased. • Push and hold [BAND] for 1 sec. to enter group selection, rotate [DIAL] to select the desired group (0–9) then push [BAND]. e Push [ ](5) to enter the list. r Push [](2) or [](8) to select “CLEAR,” then push [ ](5). • “CLEAR OK?” appears. t Push [ ](5) again to clear the list.

DV MODE OPERATION

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 N Digital mode operation The IC-80AD can be operated in digital voice mode and low- speed data operation for both transmit and receive. It can also be connected to a GPS receiver (compatible with an RS- 232 output/NMEA format/4800 bps/9600 bps) to transmit/receive position data. N Current call sign setting Set the current call sign for DV operation as follows. q Enter “CALL-S” in MENU screen. MENU ¶ CALL-S (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • Call sign screen is displayed. w Push [](2) or [](8) to select the desired call sign group, “UR,” “RPT1,” “RPT2” or “MY,” then push [ ](5). • Current call sign is displayed. Quick entry Push and hold [CS](9) for 1 sec. to enter the current call sign mode. See next page for details. • Call sign group UR : Station call signs (U01–U60), “CQCQCQ” (U--) or repeater CQ* (R-L) can be selected. * ‘/’ plus repeater call sign (R-L), ‘/’ stands for “CQCQCQ” RPT1 : “NOTUSE”* (R--) or repeater call signs (R-L) can be selected. * Direct communication (NOT USE repeater) RPT2 : “NOTUSE”* (R--) or repeater call signs (R-L) can be selected. * Direct communication or using area repeater only (NOT USE link repeater) MY : My call signs (MY1–MY6) can be selected. e Push [](2) or [](8) to select the desired call sign. Or push [](6) to enter the current call sign programming state (pgs. 36–38). • When “UR,” “RPT1” or “RPT2” is selected at step w, push [BAND] several times to select the repeater call sign groups. • When repeater call sign is selected, push and hold [CS](9) for 1 sec. to toggle the call sign and repeater name indications. r Push [ ](5) to set the selected call sign to the current call sign and exit the state. t Repeat steps w to r to set the other current call sign. y Push [MENU ] to return to frequency indication.

D Confirming current call sign

q Push and hold [CS](9) for 1 sec. to enter the current call sign mode. • Current UR call sign is displayed. Appears momentarily w Push [](2) or [](8) to select and confirm the other cur- rent call sign. • (“UR”), “R1,” “R2” and “MY” appears in sequence. • When repeater call sign is selected, push and hold [CS](9) for 1 sec. to toggle the call sign and repeater name indications. When changing the call sign q Push [ ](5) to enter the call sign selection mode. w Push [](2) or [](8) to select the desired call sign, then push [ ](5). • When “UR,” “R1” or “R2” is selected, push [BAND] several times to select the repeater call sign groups. e Push [CS](9) again to return to frequency indication. N Receiving a D-STAR repeater When the IC-80AD receives a signal from a D-STAR re- peater, it receives four call sign: caller’s call sign, called call sign, repeater call sign 1 (the repeater that caller accessed), and repeater call sign 2 (the liked repeater). You can copy the received call signs to current call signs, and you can also reply to a call. Station A Station B Repeater 449.700 MHz 444.700 MHz 444.700 MHz 449.700 MHz Uplink Downlink (transmitting freq.) (receiving freq.) • Presetting q Set the desired repeater frequency. (p. 23) • Select output power, if desired. (p. 27) w Set the shift direction of the transmit frequency. (DUP– or DUP; see p. 31 for details.) • When the auto repeater function is in use (U.S.A. and Korean versions only), this selection is not necessary. (p. 32) e Select DV mode. (p. 25) r When signal is received, display indicates received call sign. See next page for information about received call signs. 48 7 DV MODE OPERATION

DV MODE OPERATION

7 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 N Received call sign When a call is received in DV mode, the calling station and the repeater call signs being used can be stored into the re- ceived call record. The stored call signs are viewable in the following manner. Up to 20 calls can be recorded. D Desired call record indication q Enter RX call sign screen. MENU ¶ RX CAL (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • RX call sign screen is displayed. w Push [](2) or [](8) to select the desired record channel. e To confirm the received call, push [ ](5) several times to select the desired call sign from CALLER, / (CALLER’s note), CALLED, RXRPT1 and RXRPT2. CALLER : The station call sign that made the call. / : 4 character note with call sign that made the call. CALLED : The station call sign called by the caller. RXRPT1 : The repeater call sign used by the caller station in the same zone, or gateway repeater call sign of the down link repeater when the caller station is in a different zone. RXRPT2 : The repeater call sign for down link repeater. r Push [MENU ] to return to frequency indication.  For your information When receiving a call, the received station call sign is au- tomatically displayed and scrolled in sequence on the fre- quency display. This can be turned OFF in DISP set mode. (p.134) Push Call record channel NOTE: When a call is received in DV mode when the power save function is activated, the call sign may not be received correctly. This is normal, not a malfunction, because the call sign information cannot be detected during power save. Turn the power save function OFF (p. 125) if you want to receive a call sign correctly even in stand-by operation.

DV MODE OPERATION

D One-touch reply using the call record The stored call signs in the call record can be used to the call. q After receiving a call, push and hold [RX➝CS](8) for 1 sec. Or, while pushing and holding [RX➝CS](8), rotate [DIAL] to select the desired call record. The received call sign is displayed while pushing and holding with rotating . • Set your own call sign (MY) in advance. (pgs. 36, 47, 48) • The call sign in “CALLER” is stored as “UR,” “RXRPT1” is stored as “R2” and “RXRPT2” is stored as “R1.” NOTE: The display shows “-- -- -- -- -- --” with error beeps, when a call sign has been received incorrectly. In this case, no call sign is set. See previous page ‘D Desired call record indication’ for checking the received call sign. w Push [PTT] to transmit; release to receive. • Selecting a call record via RX CAL screen q Select the desired record channel as steps q and w on the previous page. w Push and hold [RX➝CS](8) for 1 sec. to copy the record channel to current call sign. e Push [PTT] to transmit; release to receive. Important! Setting call signs with the “One-touch reply using the call record” operation as at left are for temporary operation only. Therefore, the set call signs will be over-written when another call record is used to set call signs. • Never saved into a call sign memory. If you want to save the set call signs, see “Copying the call record contents into call sign memory” (p. 51) for details. ✔For your information When a call specifying your call sign is received, the call signs of the calling station and the repeater it is using can be automatically used for operation. • When “CALL W (RX call sign auto write)” (p. 133) is set to “AUTO,” the station call sign in “CALLER” is set to “UR” au- tomatically. • When “RPT W (Repeater call sign auto write)” (p. 133) is set to “AUTO,” the repeater call sign in “RXRPT1” is stored as “R2” and “RXRPT2” is stored as “R1” automatically. NOTE: The One-touch reply function can be used on the same network system, but it cannot be used over different network systems.

DV MODE OPERATION

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 N Copying the call sign D Copying the call sign memory contents This function is convenient when editing or modifying a part of the memorized call sign. q During DV mode operation, enter call sign menu. MENU ¶ CALL-S (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) w Push [](2) or [](8) to select “UR,” then push [ ](5). e Push [](2) or [](8) to select the desired call sign chan- nel to be copied. • U01–U60 are available. • When “AUTO” is set to “EDIT R” item r Push [](6) to select the call sign programming mode. • The 1st digit of the selected call sign blinks. Blank channel is selected automatically. t Modify the selected call sign as described in “Station call sign programming” (p. 37). y Push [ ](5) to store the modified call sign into the selected blank channel. NOTE: Make sure that the “EDIT R" (EDIT RECORD) item in DV set mode is set to “AUTO” or “SEL” in advance. (p. 134) NOTE: If no blank channel is available in the station call sign memory, select the desired call sign channel number as described in step u of “• When “SEL” is set to “EDIT R” item” below. • When “SEL” is set to “EDIT R” item r Push [](6) to select the call sign programming mode. • The 1st digit of the selected call sign blinks. t Modify the selected call sign as described in “Station call sign programming” (p. 37). y Push [ ](5). • Call sign channel number blinks. Call sign channel number blinks. u Push [](2) or [](8) to select the desired call sign chan- nel to store. i Push [ ](5) to store the modified call sign into the selected channel.

DV MODE OPERATION

This is a way to copy the call record contents (“CALLER,” “RXRPT1” and “RXRPT2”) into call sign memory “UR” and repeater list “R-L” at the same time or individually. q Enter RX CAL (RX call sign) mode. MENU ¶ RX CAL (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • RX call sign screen is displayed. w Push [](2) or [](8) to select the desired record chan- nel. e Push [ ](5) several times to select the desired call sign from CALLER, / (CALLER’s note), CALLED, RXRPT1 and RXRPT2. CALLER : The station call sign that made the call. / : 4 character note with call sign that made the call. CALLED : The station call sign called by the caller. RXRPT1 : The repeater call sign used by the caller station in the same zone, or gateway repeater call sign of the down link repeater when the caller station is in a different zone. RXRPT2 : The repeater call sign for down link repeater. r Push [](6) to enter copy select mode. • Copy select screen is displayed. t Push [](2) or [](8) to select the desired call sign to be copied from “C ALL,” “C UR01”–“C UR60,” “C R-L” and “CLEAR.” • “C ALL” selection won’t appear when either station call sign memory or repeater list has no blank channel. y Push [ ](5) to copy the selected record’s contents into the appropriate call sign memory or repeater lists. C ALL : Copy the caller call sign in “CALLER” to “UR” (sta- tion call sign memory) and the repeater call sign in “RXRPT1” / “RXRPT2” to the repeater lists. This selection won’t appear when either station call sign memory or repeater list has no blank channel. C UR01– : C UR60 : Copy the caller call sign in “CALLER” to “UR” (sta- tion call sign memory). This selection appears when entering the copy select mode (step r) from “CALLER” only. C R-L : Copy the repeater call sign in “RXRPT1” / “RXRPT2” to the repeater lists. This selection appears when entering the copy select mode (step r) from “RXRPT1” or “RXRPT2” only. CLEAR : Clear (erase) the selected call record contents. u Push [MENU ] to return to frequency indication. D Copying the call record contents into call sign memory

DV MODE OPERATION

7 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 DR (D-STAR Repeater) mode is used for D-STAR repeater operation. In this mode, you can select the pre-programmed repeaters and UR call sign by using [DIAL]. • DR mode operation flow chart Step 3: (RPT2 selection) Select link repeater, gateway repeater or if other station is in the same area, select NOT USE. Push PTT to transmit, release to receive. Step 1: (RPT1 selection) Select the access repeater. - Access repeater scan is useful to find a repeater. Step 2: (UR call sign selection) Select UR call sign. Calling a CQ In the same area: CQCQCQ To other area: Repeater name In the same area: NOT USE In the same zone: Repeater name To a different zone: GW Calling a specific station • Repeater settings can be stored into a memory channel. D Access repeater scan q Push [DR] to select DR mode. • DV mode is selected automatically. w Push and hold [SCAN](V/MHz) for 1 sec. to start the scan. • Scan pauses when a signal is received. • Rotate [DIAL] to change the scanning direction, or to resume manually. • Push [V/MHz] to stop the scan. During access repeater scan • Skip setting Unwanted access repeater can be skipped for rapid selection or scan. q Push [DR] to select DR mode. w Rotate [DIAL] to select the desired access repeater to be skipped. • Push and hold [BAND] for 1 sec. to enter group selection, rotate [DIAL] to select the desired group (0–9) then push [BAND]. • While pushing and holding [SKIP](5), rotating [DIAL] selects a skip channel. e Push and hold [SKIP](5) for 1 sec. to toggle the skip setting ON and OFF. • “SKIP” appears when the channel is set as skip channel. N DR (D-STAR Repeater) mode operation

DV MODE OPERATION

N Calling CQ • STEP 1 (RPT1 selection) q Push [DR] to enter DR mode. Appear Repeater selection indicator w Select the repeater group. Selecting the repeater group q Push and hold [BAND] for 1 sec., then rotate [DIAL] to select the desired repeater group. • Only assigned groups from GRP 1–GRP 9 and GRP 0 are selectable. Group indicator blinks w Push [BAND] again to release the group selection. • Push [0]–[9] to select the repeater group directly. e Rotate [DIAL] to select the access repeater. • Only repeaters that have access repeater settings programmed are selectable. • Group indicator appears momentarily when rotating [DIAL]. • Access repeater scan can be used for the selection. (p. 53) • STEP 2 (UR call sign selection) r Push and hold [UR](.) for 1 sec. to enter the UR call sign selection. UR selection indicator t Select the group as step w. • Only assigned GRP 1–GRP 9, GRP 0, GRP UR and GRP CQ are selectable. • UR call signs are selectable in GRP UR. • “CQCQCQ” is selectable in GRP CQ. • Push [BAND] several times to select “GRP UR,” “GRP CQ” and “GRP RP.”

DV MODE OPERATION

7 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 D Calling CQ in the same area (Area CQ) My call sign: JA3YUA CQ Area Zone Repeater q: NARA43 (JP3YHL) q w e r Continued instruction from step t on page 54. y Push [BAND] several times to select “GRP CQ,” then “CQCQCQ” is selected as UR call sign automatically. • The link repeater (RPT2) setting is set to “NOT USE” automati- cally. u Push [PTT] to transmit; release to receive. D Calling CQ to another area (Zone CQ/Different zone CQ) • Calling CQ in the same zone (Zone CQ) My call sign: JA3YUA Repeater q : NARA43 (JP3YHL) Repeater r : IKOMA43 (JP3YHJ) CQ q w e r Area Zone • Calling CQ to another zone (Different zone CQ) Repeater q : Repeater e : Repeater u : CQ q w e r t y u i My call sign: JA3YUA Gateway Gateway Area Zone A Zone B NARA43 (JP3YHL) HIRANO43 (JP3YHH G) HAMA43 (JP1YIU) Continued instruction from step t on page 54. y Rotate [DIAL] to select a desired repeater name. • Push [BAND] several times to select “GRP RP” or push [0]–[9] to select the repeater group in advance. Calling CQ in the same zone The link repeater (RPT2) is set to the selected repeater auto- matically. Calling CQ to another zone The link repeater (RPT2) is set to the preset gateway repeater automatically. u Push [PTT] to transmit; release to receive.

DV MODE OPERATION

N Calling a specific station • STEP 1 (RPT1 selection) q Push [DR] to enter DR mode. Appear Repeater selection indicator w Select the repeater group. Selecting the repeater group q Push and hold [BAND] for 1 sec., then rotate [DIAL] to select the desired repeater group. • Only assigned groups from GRP 1–GRP 9 and GRP 0 are selectable. Group indicator blinks w Push [BAND] again to release the group selection. • Push [0]–[9] to select the repeater group directly. e Rotate [DIAL] to select the access repeater. • Only repeaters that have access repeater settings programmed are selectable. • Group indicator appears momentarily when rotating [DIAL]. • Access repeater scan can be used for the selection. (p. 53) • STEP 2 (UR call sign selection) r Push and hold [UR](.) for 1 sec. to enter the UR call sign selection. UR selection indicator t Rotate [DIAL] to select a specific station call sign. • Push [BAND] several times to select “GRP UR” in advance.

DV MODE OPERATION

7 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 D Calling a specific station in the same area (Area call) MY call sign: JA3YUA Station call sign: JG3YMK Repeater q : NARA43 (JP3YHL) q w e r Area Zone Continued instruction from step t on page 56. • STEP 3 (RPT2 selection) y Push and hold [UR](.) for 1 sec. to enter the link repeater (RPT2) selection. u Rotate [DIAL] to select “NOT USE.” i Push [UR](.) to exit the link repeater selection. o Push [PTT] to transmit; release to receive. D Calling a specific station in the same zone (Zone call) MY call sign: JA3YUA Station call sign: JG3YMK Repeater q : NARA43 (JP3YHL) Repeater r : IKOMA43 (JP3YHJ) q w e r Continued instruction from step t on page 56. • STEP 3 (RPT2 selection) y Push and hold [UR](.) for 1 sec. to enter the link repeater (RPT2) selection. u Rotate [DIAL] to select the specific link repeater in the same zone. i Push [UR](.) to exit the link repeater selection. o Push [PTT] to transmit; release to receive.

DV MODE OPERATION

Repeater q : Repeater e : Repeater u : NARA43 (JP3YHL) HIRANO43 (JP3YHH G) HAMA43 (JP1YIU) Gateway Gateway Area Zone A Zone B q w e r t y u i MY call sign: JA3YUA Station call sign: JM1ZLK NOTE: If the other station has accessed the repeater at once, the D-STAR system will connect to the repeater au- tomatically even you don’t know where the station is (pos- sible in the same area as you, or in the same zone or a different zone). In this case, you select “GW” as the RPT2 selection. The Auto gateway setting “GW SET” is helpful (p. 134). Continued instruction from step t on page 56. • STEP 3 (RPT2 selection) u Push and hold [UR](.) for 1 sec. to enter the link repeater (RPT2) selection. i Rotate [DIAL] to select the preset gateway repeater “GW.” • Only the repeaters that have gateway capability appear. o Push [UR](.) to exit the link repeater selection. !0 Push [PTT] to transmit; release to receive. D Calling a specific station in another zone (Different zone call)

DV MODE OPERATION

7 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 D Confirming the setting q Push and hold [CS](9) for 1 sec. to enter the setting confir- mation screen. • Either UR, R1 or R2 call sign is displayed. Appears momentarily w Push [](2) or [](8) to select and confirm the other cur- rent call sign. • “UR,” “R1,” “R2,” “MY” and “FREQ” appears in sequence. e Push and hold [CS](9) for 1 sec. to toggle the name indica- tion and call sign indication. • Name indication is available only for repeater call signs that have programmed repeater names. r Push [CS](9) again to exit the setting confirmation screen.

DV MODE OPERATION

N Simplex operation in VFO D Sending CQ q Set the desired frequency. (p. 23) • Select output power, if desired. (p. 27) w Set the current call sign to your own call sign. (p. 47) e Set the current UR call sign. (p. 47) UR call sign selection q Push and hold [UR](.) for 1 sec. to enter UR call sign selection mode. • Push [BAND] several times to select “GRP CQ” (CQCQCQ) “GRP UR” (UR call sign memories) and “CS” (current call sign). • DV mode is automatically selected. w Rotate [DIAL] to select “CQCQCQ.” e Push [UR](.) to return to frequency indication mode. r Push and hold [PTT] to transmit and speak into the micro- phone at normal voice level. • Tx/Rx indicator lights red and the RF meter shows the output power. • “CQCQCQ” is displayed and scrolled in sequence on the fre- quency display depending on “TX CS” setting (p. 135). t Release [PTT] to return to receive. • The other station’s call sign will be received. • Received call signs can be stored into the received call record automatically. See page 49 for details. • Current call sign setting example (Simplex CQ) UR MY R1: (NOT USE) R2: (NOT USE) My call sign: JA3YUA CQ Confirmation q Push and hold [CS](9) for 1 sec. to enter the current call sign mode. • Current UR call sign is displayed. w Push [](2) or [](8) to select and confirm the other cur- rent call sign. • (“UR”), “R1,” “R2” and “MY” appears in sequence.

DV MODE OPERATION

7 D Calling a specific station q Set the desired frequency. (p. 23) • Select output power, if desired. (p. 27) w Set the current call sign to your own call sign. (p. 47) e Set the current UR call sign. (p. 47) UR call sign selection q Push and hold [UR](.) for 1 sec. to enter UR call sign selection mode. • Push [BAND] several times to select “GRP CQ” (CQCQCQ) “GRP UR” (UR call sign memories) and “CS” (current call sign). • DV mode is automatically selected. w Rotate [DIAL] to select the specific station call sign. e Push [UR](.) to return to frequency indication mode. r Push and hold [PTT] to transmit and speak into the micro- phone at normal voice level. • Tx/Rx indicator lights red and the RF meter shows the output power. • UR call sign is displayed and scrolled on the frequency display depending on “TX CS” setting (p. 135). t Release [PTT] to return to receive. • The other station’s call sign will be received. • Received call signs can be stored into the received call record automatically. See page 49 for details. • Current call sign setting example (Simplex call) My call sign: JA3YUA Station call sign: JG3YMK UR MY R1: (NOT USE) R2: (NOT USE) NOTE: The digital mode operation is vastly different from FM mode. One of the differences is that in digital mode the squelch does not function as in FM mode. Changing the squelch setting will not open it to hear the hiss of “white noise.” It only activates for digital squelch functions such as CSQL (Digital code squelch) or D SQL (Digital call sign squelch). 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19

DV MODE OPERATION

N Repeater operation in VFO D Calling CQ in the same area (Area CQ) q Set the desired repeater’s frequency, offset and shift direc- tion (pgs. 23, 31), then select the DV mode (p. 25). Your own call sign (step w) and station call sign (step e) can also be set as same as repeater call signs in current call sign mode (step r). w Set the current call sign to your own call sign. • See pgs. 47, 48 for current call sign setting details. e Set the current station call sign as follows: ± Push and hold [UR](.) for 1 sec. to enter UR call sign selection mode. • Push [BAND] several times to select “GRP CQ,” then “CQC- QCQ” is selected automatically. Push [UR](.) again. r Set the current repeater’s call sign as follows: z Push and hold [CS](9) for 1 sec. to enter the current call sign mode. • UR call sign is displayed. • Push and hold [CS](9) for 1 sec. to toggle the call sign and repeater name indications. x Rotate [DIAL] to select “R1,” access repeater’s call sign, then push [ ](5) to enter the current call sign selection mode. c Rotate [DIAL] to select the desired access repeat- er’s call sign, then push [ ](5) to set the call sign for “RPT1.” • Return to the current call sign mode. v Rotate [DIAL] to select “R2,” link repeater’s call sign, then push [ ](5) to set the current call sign selection mode. • “RPT2” call sign screen is displayed. b Rotate [DIAL] to select “NOT USE,” then push [ ](5). • Return to the current call sign mode. n Push [V/MHz] to return to frequency indication. t Push [PTT] to transmit; release to receive. • “CQCQCQ” is displayed and scrolled in sequence on the fre- quency display depending on “TX CS” setting (p. 135). • Current call sign setting example My call sign: JA3YUA CQ Area Zone Repeater q: JP3YHL UR MY R1 R2: (NOT USE) q w e r Pushing [BAND] selects the repeater group when selection.

DV MODE OPERATION

7 D Calling a specific station in the same area (Area call) 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 q Set the desired repeater’s frequency, offset and shift direc- tion (pgs. 23, 31), then select the DV mode (p. 25). Your own call sign (step w) and station call sign (step e) can also be set as same as repeater call signs in current call sign mode (step r). w Set the current call sign to your own call sign. • See pgs. 47, 48 for current call sign setting details. e Set the current station call sign as follows: z Push and hold [UR](.) for 1 sec. to enter UR call sign selection mode. x Rotate [DIAL] to select the desired station call sign. • Push [BAND] several times to select “GRP UR” in advance. c Push [UR](.) again to return to frequency indication. r Set the current repeater’s call sign as follows: z Push and hold [CS](9) for 1 sec. to enter the current call sign mode. • UR call sign is displayed. • Push and hold [CS](9) for 1 sec. to toggle the call sign and repeater name indications. x Push [](2) or [](8) to select “R1,” access repeater’s call sign, then push [ ](5) to enter the current call sign selection mode. c Push [](2) or [](8) to select the desired access re- peater’s call sign, then push [ ](5) to set the call sign for “RPT1.” • Return to the current call sign mode. v Push [](2) or [](8) to select “R2,” link repeater’s call sign, then push [ ](5) to set the current call sign selection mode. • “RPT2” call sign screen is displayed. b Push [](2) or [](8) to select “NOT USE,” then push [ ](5). • Return to the current call sign mode. n Push [V/MHz] to return to frequency indication. t Push [PTT] to transmit; release to receive. • UR call sign is displayed and scrolled in sequence on the fre- quency display depending on “TX CS” setting (p. 135). • Current call sign setting example My call sign: JA3YUA Station call sign: JG3YMK Repeater q : JP3YHL q w e r UR MY R1 R2: (NOT USE) Area Zone Pushing [BAND] selects the repeater group when selection.

D Calling CQ in the same zone (Zone CQ)

q Set the desired repeater’s frequency, offset and shift direc- tion (pgs. 23, 31), then select the DV mode (p. 25). Your own call sign (step w) and station call sign (step e) can also be set as same as repeater call signs in current call sign mode (step r). w Set the current call sign to your own call sign. • See pgs. 47, 48 for current call sign setting details. e Set the current station call sign as follows: ± Push and hold [UR](.) for 1 sec. to enter UR call sign selection mode. • Push [BAND] several times to select “GRP CQ,” then “CQC- QCQ” is selected automatically. Push [UR](.) again. r Set the current repeater’s call sign as follows: z Push and hold [CS](9) for 1 sec. to enter the current call sign mode. • UR call sign is displayed. • Push and hold [CS](9) for 1 sec. to toggle the call sign and repeater name indications. x Push [](2) or [](8) to select “R1,” access repeater’s call sign, then push [ ](5) to enter the current call sign selection mode. c Push [](2) or [](8) to select the desired access re- peater’s call sign, then push [ ](5) to set the call sign for “RPT1.” • Return to the current call sign mode. v Push [](2) or [](8) to select “R2,” link repeater’s call sign, then push [ ](5) to set the current call sign selection mode. • “RPT2” call sign screen is displayed. b Push [](2) or [](8) to select the desired repeater call sign in the same zone, then push [ ](5). • Return to the current call sign mode. n Push [V/MHz] to return to frequency indication. t Push [PTT] to transmit; release to receive. • “CQCQCQ” is displayed and scrolled in sequence on the fre- quency display depending on “TX CS” setting (p. 135). • Current call sign setting example My call sign: JA3YUA Repeater q : JP3YHL Repeater r : JP3YHJ CQ q w e r UR MY R1 R2 Area Zone 64 7 DV MODE OPERATION Pushing [BAND] selects the repeater group when selection.

DV MODE OPERATION

7 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 q Set the desired repeater’s frequency, offset and shift direc- tion (pgs. 23, 31), then select the DV mode (p. 25). Your own call sign (step w) and station call sign (step e) can also be set as same as repeater call signs in current call sign mode (step r). w Set the current call sign to your own call sign. • See pgs. 47, 48 for current call sign setting details. e Set the current station call sign as follows: z Push and hold [UR](.) for 1 sec. to enter UR call sign selection mode. x Rotate [DIAL] to select the desired station call sign. • Push [BAND] several times to select “GRP UR” in advance. c Push [UR](.) again to return to frequency indication. r Set the current repeater’s call sign as follows: z Push and hold [CS](9) for 1 sec. to enter the current call sign mode. • UR call sign is displayed. • Push and hold [CS](9) for 1 sec. to toggle the call sign and repeater name indications. x Push [](2) or [](8) to select “R1,” access repeater’s call sign, then push [ ](5) to enter the current call sign selection mode. c Push [](2) or [](8) to select the desired access re- peater’s call sign, then push [ ](5) to set the call sign for “RPT1.” • Return to the current call sign mode. v Push [](2) or [](8) to select “R2,” link repeater’s call sign, then push [ ](5) to set the current call sign selection mode. • “RPT2” call sign screen is displayed. b Push [](2) or [](8) to select the desired repeater call sign in the same zone, then push [ ](5). • Return to the current call sign mode. n Push [V/MHz] to return to frequency indication. t Push [PTT] to transmit; release to receive. • UR call sign is displayed and scrolled in sequence on the fre- quency display depending on “TX CS” setting (p. 135). • Current call sign setting example My call sign: JA3YUA Station call sign: JG3YMK Repeater q : JP3YHL Repeater r : JP3YHJ q w e r UR MY R1 R2 Area Zone D Calling a specific station in the same zone (Zone call) Pushing [BAND] selects the repeater group when selection.

q Set the desired repeater’s frequency, offset and shift direc-

tion (pgs. 23, 31), then select the DV mode (p. 25). w Set the current call sign to your own call sign. • See pgs. 47, 48 for current call sign setting details. e Set the current station call sign and repeater call signs as follows: z Push and hold [CS](9) for 1 sec. to enter the current call sign mode. • UR call sign is displayed. • Push and hold [CS](9) for 1 sec. to toggle the call sign and repeater name indications. x Push [ ](5) to enter the current call sign selection mode. c Push [](2) or [](8) to select the desired repeater call sign, then push [ ](5) to set the call sign for “UR.” • Return to the current call sign mode. v Push [](2) or [](8) to select “R1,” access repeater’s call sign, then push [ ](5) to enter the current call sign selection mode. b Push [](2) or [](8) to select the desired access re- peater’s call sign, then push [ ](5) to set the call sign for “RPT1.” • Return to the current call sign mode. n Push [](2) or [](8) to select “R2,” link repeater’s call sign, then push [ ](5) to enter the current call sign selection mode. • “RPT2” call sign screen is displayed. m Push [](2) or [](8) to select the specified gateway repeater call sign in the same zone, then push [ ](5). • Return to the current call sign mode. , Push [V/MHz] to return to frequency indication. r Push [PTT] to transmit; release to receive. • “CQCQCQ” is displayed and scrolled in sequence on the fre- quency display depending on “TX CS” setting (p. 135). • Current call sign setting example UR MY R1 R2 Repeater q : JP3YHL Repeater e : JP3YHH G Repeater u : JP1YIU CQ q w e r t y u i My call sign: JA3YUA Gateway Gateway Area Zone A Zone B 66 7 DV MODE OPERATION D Calling CQ to another zone (Different zone CQ) Pushing [BAND] selects the repeater group when selection.

q Set the desired repeater’s frequency, offset and shift direc-

tion (pgs. 23, 31), then select the DV mode (p. 25). w Set the current call sign to your own call sign. • See pgs. 47, 48 for current call sign setting details. e Set the current station call sign and repeater call signs as follows: z Push and hold [CS](9) for 1 sec. to enter the current call sign mode. • UR call sign is displayed. • Push and hold [CS](9) for 1 sec. to toggle the call sign and repeater name indications. x Push [ ](5) to enter the current call sign selection mode. c Push [](2) or [](8) to select the desired station call sign, then push [ ](5) to set the call sign for “UR.” • Return to the current call sign mode. v Push [](2) or [](8) to select “R1,” access repeater’s call sign, then push [ ](5) to enter the current call sign selection mode. b Push [](2) or [](8) to select the desired access re- peater’s call sign, then push [ ](5) to set the call sign for “RPT1.” • Return to the current call sign mode. n Push [](2) or [](8) to select “R2,” link repeater’s call sign, then push [ ](5) to enter the current call sign selection mode. • “RPT2” call sign screen is displayed. m Push [](2) or [](8) to select the specified gateway repeater call sign in the same zone, then push [ ](5). • Return to the current call sign mode. , Push [V/MHz] to return to frequency indication. r Push [PTT] to transmit; release to receive. • UR call sign is displayed and scrolled in sequence on the fre- quency display depending on “TX CS” setting (p. 135). • Current call sign setting example Repeater q : JP3YHL Repeater e : JP3YHH G Repeater u : JP1YIU Gateway Gateway Area Zone A Zone B q w e r t y u i UR MY R1 R2 My call sign: JA3YUA Station call sign: JM1ZLK 67 7 DV MODE OPERATION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 D Calling a specific station in another zone (Different zone call) Pushing [BAND] selects the repeater group when selection.

DV MODE OPERATION

N Message operation D TX message programming TX messages are available for up to 5 channels and each channel can be programmed with a message of up to 20 characters. q Enter “TX MSG” in MESSAG (message) screen. MENU ¶ MESSAG ¶ TX MSG (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • TX MSG screen is displayed. w Push [](2) or [](8) to select the desired transmit mes- sage channel. • TM1 to TM5 and OFF are available. • Previously message is displayed if programmed. e Push [](6) to select the message edit condition. • The 1st digit of the message blinks. r Push [](2) or [](8) to select the desired character or symbol. • If an unwanted character is entered, push [](6) or [◁](4) to select the character, then push [CLR](1) to erase the selected character, or push and hold [CLR](1) for 1 sec. to erase all char- acters following the cursor. • Push [](6) to move the cursor right; push [◁](4) to move the cursor left. t Repeat the step r to enter the desired message. • Up to 20 character messages can be set. y Push [ ](5) to store the message. u Push [MENU ] to return to frequency indication. • Available characters (A) (B) (C) (D) (E) (F) (G) (H) ( I ) (J) (Space) (K) (L) (M) (N) (O) (P) (Q) (R) (S) (T) (U) (V) (W) (9) (0) (1) (2) (3) (4) (5) (6) (7) (8) ( + ) ( ” ) ( ! ) (#) ($) (%) (&) ( ’ ) ( . ) ( : ) ( ; ) ( = ) (?) (@) ( [ ) ( \ ) ( ] ) ( ^ ) ( ( ) ( ) ) (  ) (X) (Y) (Z) ( , ) ( - ) ( / ) ( < ) ( > )

DV MODE OPERATION

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 D Message Transmission You can toggle the message transmission function ON (TM1–TM5) and OFF. When a message channel is selected, the transceiver transmits a pre-programmed text message. (default: OFF) q Set the operating frequency, call signs and other settings, such as repeater operation, as desired. w Enter “TX MSG” in MESSAG (message) screen. MENU ¶ MESSAG ¶ TX MSG (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • TX MSG screen is displayed. e Push [](2) or [](8) to select the desired transmit mes- sage channel. • TM1 to TM5 are available. r Push [ ](5) to set the message for transmission. t Push [PTT] to transmit. • The message is transmitted each time when [PTT] is pushed. • The message is transmitted each 30 sec. automatically during continuous transmission. y Release [PTT] to return to receive. u When the reply call with a message is received, the call sign and the message scrolls on the frequency display. Scrolls the received message. Appears  For your information The automatic received call sign and/or message indication can be turned OFF in DISP set mode, if desired. ± RX CS (RX CALL SIGN) (p. 134) ± RX MSG (RX MESSAGE) (p. 135) NOTE: Only one message can be stored in the IC-80AD. The received message is cleared by turning power OFF, or overwritten when another message is received.

DV MODE OPERATION

D RX message indication The received message can also be checked in MESSAG (message) screen. q Select “RX MSG” in MESSAG (message) screen. MENU ¶ MESSAG ¶ RX MSG (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • The received message is displayed. • Push [](6) or [◁](4) to scroll the message. w Push [](8) to display the station call sign (caller). e Push [ ](5) several times to return to RX MSG screen. • Push [](6) or [◁](4) to scroll the call sign. r Push [MENU ] to return to frequency indication. N Automatic reply function The automatic reply function replies to calls by a station that specified your call sign. D Automatic reply function setting q Enter “REPLY” in DV SET mode. MENU ¶ DV SET ¶ REPLY (p. 132) (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • REPLY (auto reply) screen is displayed. w Push [](2) or [](8) to turn the automatic reply function ON and OFF. OFF : Deactivate the automatic reply function. (default) ON : Reply to the call with your own call sign. e Push [ ](5). • Returns to DV SET mode automatically. r Push [MENU ] to return to frequency indication. The Automatic replay function is tur ned OFF automatically, when a manual transmission (pushing [PTT]) is performed.

DV MODE OPERATION

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 N EMR communication The EMR (Enhanced Monitor Receive) communication mode is available for digital mode operation. In the EMR communication mode, no call sign setting is necessary. When an EMR communication mode signal is received, the audio (voice) will be heard at the specified level even the volume setting level is set to minimum level, or digital call sign/digital code squelch is in use. q Enter “EMR” in DV SET mode. MENU ¶ DV SET ¶ EMR (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • EMR screen is displayed. w Push [](2) or [](8) to turn the EMR communication mode ON and OFF. OFF : EMR communication is set OFF. (default) ON : EMR communication is set ON. • When "ON" is selected, “EMR” appears instead of memory chan- nel indication. e Push [ ](5). • Returns to DV SET mode. r Push [MENU ] to return to frequency indication. “EMR” appears t Push [PTT] to transmit. y Release [PTT] to return to receive. NOTE: The EMR communication function is turned OFF automatically when turning transceiver’s power OFF

DV MODE OPERATION

N Break-in communication The break-in function allows you to break into a conversa- tion, where the two original stations are communicating with call sign squelch enabled. q While receiving an another station’s communication, push and hold [RX©CS](8) for 1 sec. to set the communicating station’s call sign. • When a call sign has not been received correctly, error beeps sound and no call sign is set. Try to set the call sign of a com- municating signal again, or set the call sign manually. w Enter “BK” in DV SET mode. MENU ¶ DV SET ¶ BK (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • BK screen is displayed. e Push [](2) or [](8) to turn the Break-in function ON and OFF. • When "ON" is selected, “BK” appears instead of memory chan- nel indication r Push [ ](5). • Returns to DV SET mode. t Push [MENU ] to return to frequency indication. “BK” appears y When both stations are in standby, push [PTT] to transmit a break-in call. • The programmed call sign station receives the break-in call as well as your call sign. u Wait for the reply call from the station who receives the break-in call. i After receiving the reply call, communicate normally. o To cancel the break-in function, turn the Break-in function OFF in the DV SET mode as steps w to t. NOTE: The break-in function is turned OFF automatically when turning transceiver’s power OFF

DV MODE OPERATION

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 • How to use break-in? While operating with the digital call sign squelch (p. 151), the squelch never opens (no audio sounds) even if a call is received, unless your own call sign (“MY”) is specified. However, when the call including the “BK ON” signal (break-in call) is received, the squelch will open and audio sounds even if the call is specified for another station. Station A Station B Station C • Station C calling to Station A with “BK OFF” Station A Station B Station C • Station C calling to Station A with “BK ON” Station A and B are communicating using the digital call sign squelch. Station A and B are communicating using the digital call sign squelch. Station B never hears that Station C is calling Station A. Station B also hears that Station C is calling Station A.

DV MODE OPERATION

N Low-speed data communication In addition to the digital voice communication, low-speed data communication is available. The optional OPC-1529R DATA COMMUNICATION CABLE and serial data communication software (purchase locally) are re- quired in addition. NOTE: Turn OFF "GPS-TX" (p. 138) in advance to operate the low-speed data communication. D Connection Connect the transceiver to your PC using with the optional OPC-1529R as illustrated below. OPC-1529R (optional) to [DATA] PC D Low-speed data communication application setting Configure the low-speed data communication application as follows. • Port : The same COM port number as IC-80AD’s • Baud rate : 9600/4800 bps (p. 126) • Data : 8 bit • Parity : None • Stop : 1 bit • Flow control : Xon/Xoff D Low-speed data communication operation NOTE: Confirm that in AUTO, the computer controls when [PTT] is activated to send data and the user doesn’t have to operate the radio. q Set the current call signs, etc. as described in “Current call sign setting” (p. 47), “Simplex operation in VFO” (p. 60) and “Re- peater operation in VFO” (p. 62). w Refer to the instructions of the low-speed data communica- tion application. e To transmit data • At the same time as your voice audio, push and hold [PTT] to transmit while sending data from the PC. Release [PTT] to re- ceive. • Under computer control, see Transmission condition setting at right.

DV MODE OPERATION

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 D Transmission condition setting q Enter “DATATX” in DV SET mode. MENU ¶ DV SET ¶ DATATX (p. 132) (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) w Push [](2) or [](8) to select “PTT” or “AUTO.” PTT : The input data from [DATA] are transmitted when pushing [PTT]. (default) AUTO : The input data from [DATA] are transmitted auto- matically when the data are input. e Push [ ](5) to return to DV SET mode, and push [MENU ] to return to frequency indication.

DV MODE OPERATION

D DV auto detect The “DV” mode indicator and “FM” mode indicator blink when a non-DV signal is received during DV mode operation. When a signal other than DV mode is received, the IC-80AD DV automatic detection switches to monitor in FM mode. q Enter “DV DET” in DV SET mode. MENU ¶ DV SET ¶ DV DET (p. 133) (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) w Push [](2) or [](8) to turn the DV automatic detect function ON and OFF. OFF : “DV” blinks then “FM” also blinks, however the transceiver receives in DV mode even if non-DV mode signals are received. ON : “DV” blinks then “FM” also blinks when the trans- ceiver monitors the receiving signal other than DV mode, the signal is in FM mode. e Push [ ](5) to return to DV SET mode. r Push [MENU ] to return to frequency indication. NOTE: The received FM audio may be distorted when receiving an FM signal with DV automatic detect function. D Packet loss indication While operating voice communication or low-speed data com- munication via the internet network from one zone to another zone, some packets may be lost due to network error (poor data throughput performance). In such a case, the IC-80AD displays “P-LOSS” instead of frequency indication on the dis- play to indicate Packet Loss has occurred. Appears N Other functions in DV mode

N GPS operation

You can display GPS data when in FM, FM-N, WFM, AM and DV modes. You can also transmit GPS data when in DV mode. To receive GPS data, connect an optional GPS speaker microphone (HM-189GPS) or connect a third-party GPS receiver* that has an RS-232C output and NMEA data format. Third-party GPS receivers connect to the IC-80AD’s [DATA] jack. In addition, the GPS message transmission is also available in GPS mode operation. * Set “GPS-TX” to “DVG” or “DVA” at step w of next page when connecting a 3rd party GPS receiver. NOTE: The IC-80AD receives GPS data (position, etc.) from the HM-189GPS only when the IC-80AD is receiving. When transmitting, GPS data are not updated and the IC-80AD transmits the GPS data it received before you pushed [PTT]. • When connecting the HM-189GPS HM-189GPS (optional) Top key to [SP/MIC] • When connecting the GPS receiver OPC-1529R (optional) to [DATA] to RS-232C port (null modem adapter is required) GPS receiver

D Sentence formatter setting

q Enter “GPS-TX” in GPS mode. MENU ¶ GPS ¶ GPS-TX (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • GPS-TX screen is displayed. w Push [∫](2) or [√](8) to select “DVG.” e Push [ ](5) to select GPS sentence screen. r Push [∫](2) or [√](8) to select the desired GPS sentence, then push [ ](5). • A total of 6 sentences, RMC, GGA, GLL, GSA, VTG and GSV are available. t Push [∫](2) or [√](8) to select to turn the sentence usage ON and OFF. y Push [ ](5) to return to GPS sentence screen. u Repeat the steps r to y to set another GPS sentence usage. • Up to 4 GPS sentences are usable at the same time. i Push [MENU ] to return to frequency indication. NOTE: Set the GSV sentence to OFF when sending the GPS mes- sage to conventional digital transceivers (IC-2820, ID-800H, IC-91AD, IC-V82, IC-U82). The GSV sentence is incompatible with them. Those trans- ceivers will not display GPS messages properly if sent as a GSV sentence from the IC-80AD. 78 8 GPS/GPS-A OPERATION

D GPS message programming

q Enter “TX GPS” in MESSAG screen. MENU ¶ MESSAG ¶ TX GPS (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • TX GPS screen is displayed. w Push [ ](5) to select the message edit condition. • The 1st digit of the message blinks. e Push [∫](2) or [√](8) to select the desired character or symbol. r Push [](6) to select 2nd digit, then push [∫](2) or [√](8) to select the desired character or code. • Push [](6) to move the cursor right; push [◁](4) to move the cursor left. • 2nd digit blinks (1st digit stops blinking). t Repeat step r to enter the desired message. • Up to 20-character messages can be set. y Push [ ](5) to store the message. u Push [MENU ] to return to frequency indication. D GPS message automatic transmission q Enter “GPS.ATX” in GPS mode. MENU ¶ GPS ¶ GPS.ATX (p. 142) (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • GPS AUTO TX screen is displayed. w Push [](2) or [](8) to select the desired position data transmitting interval from 5 sec., 10 sec., 30 sec., 1 min., 3 min., 5 min., 10 min., 30 min. and OFF. • The GPS message is also transmitted if programmed. e Push [ ](5) to return to GPS mode. r Push [MENU ] to return to frequency indication. NOTE: Your own call sign (“MY”) must be set to activate the GPS automatic transmission. [NOTICE] “5SEC” cannot be selected when 4 GPS sentences are se- lected. • Only use GPS message automatic transmission in sim- plex mode. • Automatic GPS message transmission through a re- peater may interfere with other communications.

D Received GPS message indication

q Enter “RX GPS” in MESSAG screen. MENU ¶ MESSAG ¶ RX GPS (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • RX GPS screen is displayed. w Push [ ](5) several times to scroll the message. e Push [ ](5) to return to the MESSAG screen. r Push [MENU ] to return to frequency indication. D Position indication q Enter “GPS.POS” in GPS mode. MENU ¶ GPS ¶ GPS.POS (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • GPS POS screen is displayed. w Push [](2) or [](8) to select the position data indica- tion. • MY POS : Displaying own latitude and longitude. • RX POS : Displaying (caller) other station latitude and longi- tude. • ELEVAT : Displaying own elevation. • TIME : Displaying the time. • DISTAN : Displaying distance from (caller) other station. • CALLER : Displaying the call sign of (caller) other station. e Push [ ](5) to enter the selection. r Push [ ](5) to return to the “GPS.POS” screen. See “MY POS” and “RX POS” operations at next page. t Push [MENU ] to return to frequency indication. NOTE: Depending on the receiving conditions of the GPS signals, your elevation may change even though you are stationary.

• Selectable items

My position Received position Elevation Distance Caller Time • Position indication My position My position 35°45.00’N 135°35.00’E S/RF meter indicates the selection Push Push Push North or South East or West These sample indications assume that “P FORM” is selected “mm.mm” and “UNITS” is selected “Ft/ml.” (p. 136)

D Saving own/received position data

q Enter “GPS.POS” in GPS mode. MENU ¶ GPS ¶ GPS.POS (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • GPS POS screen is displayed. w Push [](2) or [](8) to select the position data indica- tion. • MY POS : Displaying own latitude and longitude. • RX POS : Displaying (caller) other station latitude and longi- tude. • ELEVAT : Displaying own elevation. • TIME : Displaying the time. • DISTAN : Displaying distance from (caller) other station. • CALLER : Displaying the call sign of (caller) other station. e Push [ ](5) to enter the selection. r Push and hold [S.MW](M/CALL) for 1 sec. to save the se- lected position data to GPS memory (G00). • The M-CH number advances automatically in case the next M- CH already contains. • 50 GPS M-CH are available. • Push [M/CALL] to display stored position data. D Displaying direction and forward Displaying own direction, received station’s direction and set position and direction in the GPS memory. q Enter “D/F” in GPS mode. MENU ¶ GPS ¶ D/F (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • D/F (Direction/Forward) screen is displayed. w Push [](2) or [](8) to select “MY,” “RX” and “GPS.M” [Indication items] • MY : Displays own direction, elevation and the time. • RX : Displays other station’s direction and distance from own position. • GPS.M : Displays the direction and distance from own posi- tion of alarm setting for the memorized position in the GPS memory. e Push [ ](5) to enter the selection. • 16 compass points are available. r Push [ ](5) several times to select other information. t Push [MENU ] to return to frequency indication.

• Direction indication example

N NE ENE NNE (N -- --) (S -- --) (E -- --) (W -- --) (NW --) (NE --) (SW --) (SE --) SE ESE SSE SSW WSW WNW NNW SW NW W E MY S RX GPS.M 1 2 3 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19

D GPS data addition

q Enter “GPS.MEM” (GPS memory) in GPS mode. MENU ¶ GPS ¶ GPS.MEM (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • GPS memory selection screen is displayed. w Push [ ](5) to enter the new GPS memory channel pro- gramming state. e Push [](2) or [](8) to select the desired items, “NAME,” “TIME,” “LAT” (LATITUDE) or “LON” (LONGITUDE), then push [](6) to edit the selected item. r Push [](2) or [](8) to select the desired character or number. • Push [](6) to move the cursor right; push [◁](4) to move the cursor left. t Repeat step r to enter the desired latitude data, then push [ ](5) to program the item. y Repeat steps e to t to program the other items. • Up to a 6 character name can be programmed. u Push [ ](5) to store the GPS data. i Push [MENU ] to return to frequency indication.

D GPS alarm setting

GPS alarm sounds when your own position is close the spec- ified position. This function can be set to use information from the received channel, a specified GPS memory channel or all GPS memory channels. q Enter “ALM-CH” in GPS mode. MENU ¶ GPS ¶ ALM-CH (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • Alarm setting screen is displayed. w Push [](2) or [](8) to select “RX,” “CH,” “ALL” or “OFF.” • “RX”, “ALL”, one of the memory channel can be selected. • Skip next step e when RX, ALL or OFF is selected. Alarm mark appers. e Push [ ](5), then push [](2) or [](8) to select the de- sired memory channel. • Memory name or channel number appears when the channel is selected. Alarm mark appers. r Push [ ](5) to set the alarm function and return to ALM- CH (GPS memory) screen. t Push [MENU ] to return to frequency indication.  For your information! • When “ALL” or memory channel is selected in step w, the alarm function depends on “ALM1” setting in GPS mode (p. 88). • When “RX” or “CH” is selected in step w, the alarm function depends on “ALM2” setting in GPS mode (p. 89).

D GPS alarm setting in GPS memory channel

GPS alarm setting for a specified GPS memory channel is available on GPS memory channel indication. q Enter “GPS.MEM” in GPS mode. MENU ¶ GPS ¶ GPS.MEM (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • GPS memory selection screen is displayed. w Push [](2) or [](8) to select the desired memory chan- nel. • Memory name or channel number appears when the channel is selected. e Push [M/CALL] to switch the alarm function ON or OFF. Alarm mark appers. r Push [◁](4) to return to GPS.MEM (GPS memory) screen. t Push [MENU ] to return to frequency indication.  For your information! • When a memory channel is selected in step e, the alarm function depends on “ALM1” setting in GPS mode (p. 88).

D GPS memory clearing

• Clear all memory channels q Enter “GPS.MEM” in GPS set mode. MENU ¶ GPS ¶ GPS.MEM (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • GPS memory selection screen is displayed. w Push [](2) or [](8) to select “CLEAR ALL,” then push [ ](5). • “CLEAR OK?” appears. e Push [ ](5) again to clear all memory channels. • 2 beep sounds, then all memory channels are cleared. r Push [◁](4) to return to GPS.MEM (GPS memory) screen. t Push [MENU ] to return to frequency indication. • Clear desired memory channel to be cleared q Enter “GPS.MEM” in GPS set mode as described at left. w Push [](2) or [](8) to select the desired GPS memory channel to be cleared, then push [](6). e Push [](8) several times to select “CLEAR,” then push [ ](5). • “CLEAR OK?” appears. r Push [ ](5) again to clear the list. • 2 beep sounds, then the selected memory channel is cleared. • Remaining channels scroll up. t Push [◁](4) to return to GPS.MEM (GPS memory) screen. y Push [MENU ] to return to frequency indication.

D Alarm area 1

Sets GPS alarm active range from 00.08′ to 59.99′ in 00.01′ steps. (default: 00.25′) q Enter “ALM1” in GPS set mode. MENU ¶ GPS ¶ ALM1 (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • ALM1 setting screen is displayed. When “P FORM” (position format) (p. 136) is selected “mm.SS.” When “P FORM” (position format) (p. 136) is selected “mm.mm.” w Push [](2) or [](8) to set the desired alarm area. • Push [](6) to move the cursor right; push [◁](4) to move the cursor left. e Push [ ](5) to set the area. r Push [MENU ] to return to frequency indication. The alarm area 1 function is available when the “GPS ALARM” function ALL is ON. 00.25’ 00.25’ 00.25’ 00.25’ Your position Point A Point C Point B Point D N • Example: Your position : 35°N/135°E ALM AREA1 setting : 00.25’ (default) • Position of point A : 35°00.25’N/134°59.75’E • Position of point B : 35°00.25’N/135°00.25’E • Position of point C : 34°59.75’N/134°59.75’E • Position of point D : 34°59.75’N/135°00.25’E When the target position comes into the alarm area shown above, the GPS alarm sounds. These sample indications assume that “P FORM” is selected “mm.mm.” (p. 136)

D Alarm area 2

Selects GPS alarm active range from “BOTH,” “EXTEND” and “LIMIT” when “CH” or “RX” is selected at GPS alarm setting. q Enter “ALM2” in GPS mode. MENU ¶ GPS ¶ ALM2 (Push [MENU ]), (Push [](2)/[](8), then push [ ](5).) • ALM2 setting screen is displayed. w Push [](2) or [](8) to select the desired alarm setting, then push [ ](5) to set. • BOTH : GPS alarm† will sound when a target posi- tion enters both 500 m* (547 Y)* and 1 km* (1094 Y)* range. (default) • EXTEND : GPS alarm‡ will sound when a target position enters 1 km* (1094 Y)* range. • LIMITE : GPS alarm‡ will sound when a target position enters 500 m* (547 Y)* range. *Approximate † One beep sounds when coming within 1 km (1094 Y) and three beep sounds when coming within 500 m (547 Y). ‡ Three beep sounds. e Push [MENU ] to return to frequency indication. Extended range (approx. 1 km; 1094 Y) Limited range (approx. 500 m; 547 Y) Your position • Example: The target position definitions for Alarm area 2. Alarm indication When a target position comes into the alarm area, below indication appears. Appears • Push any key to return to frequency indication, but “S” indica- tor continues to blink in the area.

■ GPS-A operation

D GPS-A function Set the following to activate the GPS-A function. q Select the DV mode operation (p. 25) w Select “GPS.ATX” (GPS transmission mode) to DVA. (p. 138) e Set “GPS.ATX” (GPS auto transmission timer). (p. 142) r Set the GPS-A set items. (pgs. 139–142) D GPS-A code details In GPS-A operation, following codes are transmitted to the PC connected to the IC-80AD. GPS-A code is based on APRS® code. (APRS® : Automatic Position Reporting System) JA3YUA-1>API80,DSTAR∗:/002338h3437.38N/13534.24E>000/000/I am here! Can you watch me? Your own call sign Unproto address Time stamp Time stamp h; H.M.S (Hour/Minute/Second) z; D.H.M (Day/Hour/Minute) Latitude Longitude Data extension Comment GPS-A symbol (Car) • GPS-A code details

N General description

The IC-80AD has 1050 memory channels, and 2 call chan- nels. Memory channels include 50 scan edge memory chan- nels (25 pairs) for storage of often-used frequencies. Also, 26 memory banks, A to Z, are available in each band for storing groups of frequencies, etc. Up to 100 channels can be assigned to a bank. D Memory channel contents The following information can be programmed into memory channels: • Operating frequency (p. 23) • Operating mode (p. 25) • Duplex direction (+DUP or –DUP) with an offset frequency (p. 31) • Subaudible tone encoder (p. 29), tone squelch or DTCS squelch ON/OFF (p. 150) • Subaudible tone frequency (p. 119), tone squelch fre- quency or DTCS code with polarity (pgs. 119, 120) • Scan skip information (p. 108) • Memory bank (p. 95) • Memory name (p. 97) • Tuning step (p. 22) • Call sign squelch or Digital code squelch* (p. 148) • Station call sign* (pgs. 37, 47) • RPT1/RPT2 call sign* (pgs. 38, 47) *Available for DV mode operation only. NOTE: Memory data can be erased by static electricity, electric transients, etc. In addition, they can be erased by malfunction and during repairs. Therefore, we recommend that memory data be written down or be saved to a PC using the CS-80/880 CLONING SOFTWARE (free download software).

N Selecting a memory channel

D Using [DIAL] q Push [M/CALL] to select memory mode. • Pushing [M/CALL] selects memory, call, TV* and weather† channels. w Rotate [DIAL] to select the desired memory channel. • Only programmed channels are displayed. [DIAL] Appears Rotate [DIAL] to select the memory channel. * Appears only when TV channels are programmed via the CS-80/880 (free download software). † Available for the U.S.A. version only. D Using the Numeral keys q Push [M/CALL] to select memory mode. • Pushing [M/CALL] toggles memory, call, TV* and weather† channels. w Use the numeral keys to enter 3 digits to select the desired memory channel. • The blank channels are also selectable. • Example— selecting memory channel “25” Push [M/CALL], then push [0], [2], [5]. The entered memory channel is selected. Appears Numeral keys * Appears only when TV channels are programmed via the CS-80/880 (free download software). † Available for the U.S.A. version only. 92 9 MEMORY/CALL CHANNELS