Inter-m PP-6214 Operation Manual
Read Online
Read the Inter-m PP-6214 Operation Manual online using the built-in PDF viewer.
Text of the manual
* Rack mount products in the Western Hemisphere(North America, South America,
and the Caribbean) do not have handles installed due to customer preference.
Important Safety Instructions.............................................................................................................2
Features............................................................................................................................................3
Accessories.....................................................................................................................................3
Operation ........................................................................................................................................3
Front Panel ......................................................................................................................................4
Rear Panel .......................................................................................................................................6
Applications ....................................................................................................................................8
Block Diagram ................................................................................................................................9
Specifications ................................................................................................................................10
Service
Procedures....................................................................................................................................11
Schematic.....................................................................................................................................11
Parts List .......................................................................................................................................11
Variations and Options ...............................................................................................................11
Warranty .......................................................................................................................................11
A personal welcome to you from the management and employees of Inter-M
All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value
and we are delighted you have purchased one of our products.
We sincerely trust this product will provide years of satisfactory service, but if anything is not to your comple
satisfaction, we will endeavor to make things right.
Welcome to Inter-M, and thank you for becoming part of our worldwide extended family!
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
WARNING
To prevent fire or shock hazard, do not
expose the unit to rain or moisture.
*Do not install this equipment in a confined space such as a book case or similar unit.
*The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such vases, shall be placed on the apparatus.
*Worded: “WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING-WATER AND MOISTURE: Unit should not be used
near water(e.g. near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken
so than objects do not fall and liquids are not spilled into the enclosure through openings.”
This symbol is intended to alert the user to the
presence of uninsulated “dangerous voltage” within
the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to
persons.
This symbol is intended to alert the user to the
presence of important operation and maintenance
(servicing) instructions in the literature accompanying
the appliance.
Caution:
To prevent electric shock do not use this (polarized) plug with
an extension cord, receptacle or other outlet unless the blades
can be fully inserted to prevent blade exposure.
Attentions: Pour prévenir les chocs électriques ne pas utiliser cette
fiche polarisée avec un prolongateur, une prise de courant
on une autre sortie de courant, sauf si les lames peuvent
étre insérées à fond sans en laisser aucune partie à
découvert.
Although your PP-6214 is neither complicated nor difcult to operate, we recommend you take a few minutes
read this brief manual and familiarize yourself with the important information regarding product features, setup
and operation.
As with most electronic devices, we strongly recommend you retain the original packaging. In the unlikely even
the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.
Installation
Installation
Environment
Never place this product in an environment which could alter its performance or reduce its service life. Suc
environments usually include high levels of heat, dust, moisture, and vibration.
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
amplifers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blade
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wi
blade or the third prong are provided for your safety. If the provided plug does not ft into your outlet, con
an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
11. Only use attachments/accessories specifed by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specifed by the manufacturer, or sold with the apparatu
When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualifed service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.
S3125A
S3125A
- VERSATILE AND COMPACT
Flexible mix architecture in a space-saving two RU package.
- TWELVE INPUTS AND TWO OUTPUTS
Eight mono inputs and two stereo inputs, plus a stereo output.
- INPUT AND OUTPUT METERING
Peak meters on input channels, plus multi-segment LED metering to monitor your output signal.
- THREE-BAND EQ
Three-Band EQ control on output section
- ON-BOARD PHANTOM POWER
Built-in +18VDC phantom power for condenser microphones
- AC OR DC OPERATION
Runs on 100-120VAC, 220-240VAC, or 24VDC for true portability.
Accessories
One detachable AC power cord is provided for use with this product.
Operation
Operation
Make certain that speakers and input sources are properly connected before switching on.
Keep volume levels turned down before switching on.
NOTE: The system’s operation is delayed by approximately three seconds after pressing the power switch. This is
due to the built-in protection circuitry, designed to protect speakers and other system components.
1. TRIM CONTROLS 1-8
These knobs provide continuous control of the gain level for the associated input channel.
2. PEAK INDICATORS 1-8
These LED indicators light when the input signal to the associated channel is 3dB below clipping. If th
indicator is lit steadily, reduce the channel’s Trim level (1) to avoid distortion.
3. GAIN SELECT SWITCHES 9/10 – 11/12
These switches select the input gain level for Stereo Channels 9/10 and 11/12. You may select between
+4dB, -10dB or –20dB input level, depending on your input source. If the signal is too weak (very low level
select a higher setting; if the signal is too hot (overloaded and distorted), select a lower setting.
4. EQ CONTROLS
These knobs provide continuous control of equalization for the stereo (master) output. Three bands o
equalization are provided:
Low: 80Hz, ±12dB, Shelving
Mid: 800Hz ±12dB, Shelving
High: 8kHz ±12dB, Shelving
5. MAIN OUTPUT LEVEL CONTROLS
These sliders provide control of the stereo (master) output level. The output level may be monitored
by the Output Level Meters (6).
6. OUTPUT LEVEL METERS
These fve-segment LED meters monitor the level of the stereo (master) output signal.
12
12
12
12
12
12
8KHz
800Hz
80Hz
10
0
10
0
60
16 TRIM
PEAK
2
1
L
E
N
N
A
H
C
L
E
N
N
A
H
C
L
E
N
N
A
H
C
L
E
N
N
A
H
C
L
E
N
N
A
H
C
L
E
N
N
A
H
C
L
E
N
N
A
H
C
L
E
N
N
A
H
C
PRIORITY
10
0
PEAK
10
0
PEAK
10
0
PEAK
10
0
PEA
10
0
PEAK
10
0
PEAK
10
0
PEAK
10
0
1
0
0
4dB
10dB
20dB
4dB
10dB
20dB
12
12
12
12
12
12
8KHz
800Hz
80Hz
EQ
1
2
10
0
10dB
PRE AMPLIFIER
PP
9214
2
1
POWER
OFF
ON
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
TRIM
60
16
30
14
60
16
30
14
60
16
30
14
60
16
30
14
60
16
30
14
60
16
30
14
60
16
30
14
TRIM
6
1
3
1
TRIM
TRIM
TRIM
TRIM
TRIM
1
2
MAIN
CHANNEL
10 CHANNEL
12
1
0
1
9
8
11
3
7
6
5
4
2
7. PHANTOM POWER SWITCH AND INDICATOR
Pressing this switch activates the +18VDC phantom power supply to the Mic Inputs 1-8, for use wit
condenser mics requiring external power. When Phantom Power is active, the LED indicator lights. Push this
switch again to turn of Phantom Power.
8. CHANNEL SELECTOR SWITCHES 1-8
These buttons assign the channel’s input signal to one or both of the stereo outputs.
9. CHANNEL OUTPUT LEVELS 1-8
These knobs provide continuous control of the associated channel’s output level.
10. PRIORITY LEVEL CONTROL
This knob provides continuous control of the volume of the input signal of the chime, siren, or other au
source connected to the Priority Input jacks on the rear panel. When signal is present at the Priority Inp
jacks, all other signals except Channel 1 are muted.
11. POWER SWITCH
Pressing this switch turns the unit on, as indicated by the Power LED in the switch. Pressing it again
turns the unit of.
1. AC FUSE HOLDER
This holder contains the AC overload protection fuse. If the fuse has blown out, replace it with a fuse of
same type and rating. If the fuse continues to blow, refer servicing to a qualifed service technician.
2. INSERTS
These unbalanced 1/4” TRS jacks are provided for input of an audio source before the master fader. The
input signal is unafected by the Channel Input levels.
3. LINE INPUTS 9-12
Line-level inputs on unbalanced RCA and 1/4” phone connectors. These are provided as two sets of stereo
inputs (9/10 and 11/12).
4. REC OUTPUT
These two unbalanced 1/4” line-level inputs are provided for connecting to an external recording device.
5. PRIORITY INPUT
These two unbalanced 1/4” line-level inputs are provided for priority connection of chime/siren equipment.
When input signal is present on these inputs, all other audio inputs except Channel 1 are automatically
muted.
6. MUTE SWITCH
When this switch is pressed, priority muting is activated, and all signals except Channel 1 and Priority Inpu
are muted.
7. AC POWER INPUT
Connect the supplied standard AC input cable here.
DC INPUT
24V
LINE
INSERT
INSERT
REC OUTPUT
PRIORITY INPUT
MIC
MIC
MIC
MIC
MIC
MIC
MIC
MIC
CH 2
OUTPUT
OUTPUT
MUTE
ON
OFF
LINE
LINE
LINE
LINE
LINE
LINE
CH 5
CH 4
CH 3
CH 2
CH 1
CH 8
CH 7
CH 6
CH 1
CH 12
CH 10
CH 11
CH 9
FUSE
T400mAL/250V
~ AC INPUT
230V 50Hz
S N
6
5
4
3
2
1
0
1
9
8
7
11
8. MAIN OUTPUTS
These are balanced XLR output jacks for connecting to the input of a power amp.
9. DC INPUT TERMINALS
These terminals are provided for the connection of backup battery. Connect a 24VDC battery source to these
terminals. Make certain the red terminal is connected to the battery’s positive (+) side, and the black termin
to the battery’s negative (–) side.
10. MIC INPUTS 1-8
Mic-level inputs on balanced three-pin XLR connectors.
11. LINE INPUTS 2-8
Line-level inputs on balanced 1/4” phone connectors.
DC OUTPUT 24V,1AMAX
REMOTE
C-SW-H
GND
( )
( )
S N
SWED 3
(2000W)
SWED 2
(2000W)
SWED 1
(2000W)
SWITCHED
DC OUT 24V
5A MAX
( )
( )
SWITCHED DC OUT 24V
(RACK ONLY)
(AMP ONLY)
AC INPUT
230V/50Hz,217VA
~
www.inter-m.com
UNSWED
(700W)
DC INPUT
24V
FUSE
T315mAL / 250V
UNBAL / 75Ω
LOOP
ANT.
L
R
STEREO
MONO(BAL)
MONO(BAL)
VARIABLE
FIXED
S N
www.inter-m.com
OUTPUT
ANT
~AC INPUT
120V 60Hz, 11W
RESET
FM
AM
DIGI-LINK
PB-9207A
AC INPUT : 220V 50Hz, 139VA
FUSE : 1A / 250V
~
BATTERY IN
( )
( )
N
S
PE-9103A
PP-6214
DC INPUT
24V
LINE
INSERT
INSERT
REC OUTPUT
PRIORITY INPUT
MIC
MIC
MIC
MIC
MIC
MIC
MIC
MIC
CH 2
OUTPUT
OUTPUT
MUTE
ON
OFF
LINE
LINE
LINE
LINE
LINE
LINE
CH 5
CH 4
CH 3
CH 2
CH 1
CH 8
CH 7
CH 6
CH 1
CH 12
CH 10
CH 11
CH 9
PD-9359E
S N
AC INPUT
BATTERY
(DC 24V)
PT-9107SD
PC-9335
PA-9312
PA-9324
MIC
CD-3500
MODEL NO. PE-9103A
MADE IN KOREA
CHIME/SIREN
NO USER SERVICEABLE PARTS INSIDE.
RISQUE DE CHOC ELECTRIQUE NE
CTRIC SHOCK, DO NOT REMOVE COVER.
REFER SERVICING TO QUALIFIED SERVICE
CAUTION;
AVIS;
TO REDUCE THE RISK OF ELE-
PERSONNEL.
PAS OUVRIR.
DC INPUT
24V
S N
2 TONE
WEST
MINSTE
OUTPUT
REMOTE CHIME
AC INPUT
230V 50Hz, 217VA
BATTERY
INPUT 24V
Frequency Response (+1/-3dB)...................................................................................................
20Hz-20kHz
T.H.D..........................................................................................................................
...........Less than 0.5%
Input Sensitivity/Impedance
Mic Input 1-8 ..........................................................................................................-60dB/60
0ΩBalanced
Line Input 2-8 ..........................................................................................................-30dB/1
0kΩBalanced
Line Inputs 9-12..............................................................................+4dB, -10dB, -20dB/10k
ΩUnbalanced
Output/Impedance
Ch 1-2 (Master)........................................................................................................+4dB/600
ΩBalanced
Rec Out ..............................................................................................................-10dB/10k
ΩUnbalanced
Insert......................................................................................................................0dB
/10k ΩUnbalanced
Residual Noise
All Faders Min.................................................................................................................
..................90dB
All Faders Min, Master Fader Max...............................................................................................
.......70dB
Crosstalk
Input to Output ................................................................................................................
..................70dB
Adjacent.......................................................................................................................
....................70dB
- GENERAL
Power Source.............................................100–120VAC or 220–240VAC; 50/60Hz, 24VDC Auto-Switching
..............................................................
(Supplied AC mains transformer depends on country requirements)
Power Consumption ..............................................................................................................
...............9.8W
Weight.........................................................................................................................
.........12.8kg/34.3lb
Dimensions................................................................482(W) x 88(H) x 280(D)mm/19(W) x 3.5(H) x 11(D)in
* Specifcations and design subject to change without notice.
Ensure the problem is not related to operator error, or system devices that are external to this unit. Informat
provided in the troubleshooting portion of this manual may help with this process. Once it is certain that
problem is related to the product contact your warranty provider as described in the warranty section of th
manual.
Schematic
A Schematic is available by contacting your warranty provider.
Parts List
A Parts List is available by contacting your warranty provider.
Variations and Options
Variations and Options
Variations
Products supplied through legitimate sources are compatible with local AC power requirements.
Options
No optional items are available for this product.
Wa rranty
Wa rranty
Warranty terms and conditions vary by country and may not be the same for all products. Terms and condition
of warranty for a given product may be determined frst by locating the appropriate country which the produ
was purchased in, then by locating the product type.
To obtain specifc warranty information and available service locations contact Inter-M directly(in Korea or the
USA) or the authorized Inter-M Distributor for your specifc country or region.