Intermec EasyCoder 501 SA Installation Instructions

Brand: Intermec
Category: Printer
Model: EasyCoder 501 SA (Installation Instructions)
File Type: PDF
File Size: —
Pages: 5
Text of Intermec EasyCoder 501 SA Installation Instructions

Intermec EasyCoder 501 SA Label-Taken Sensor Kit

P/N 1-960350-06 Edition 5 September 1998 Installation Instructions

Intermec EasyCoder 501 SA EasyCoder 401/501/601 – Installation Instructions

1 This booklet contains instructions on how to install the Label- Taken Sensor Kit (LTS) on EasyCoder 401, EasyCoder 401 Linerless, EasyCoder 501, and EasyCoder 601 printers. Installa- tion should preferably be performed by an authorized service technician. For information on how to use the label-taken sensor, please refer to the Technical Manual for EasyCoder 401, EasyCoder 401 Linerless, EasyCoder 501,
EasyCoder 401/501/601 – Installation Instructions 2 K Turn off the power. For double security, pull the power cord out of the mains receptacle at the rear plate of the printer. K Open the right-hand door. K Open the front hatch. K Using a #T10 Torx screwdriver, remove the six or eight screws that hold the left-hand cover (see illustration). K Remove the cover. K Press the reflecting sensor assembly into the bracket as illustrated below. LABEL-TAKEN SENSO
EasyCoder 401/501/601 – Installation Instructions 3 K Using the screw included in the kit, fit the sensor/bracket assembly to the inner wall of the printer unit as shown by the two illustrations below. Fit the cable underneath the top part of the bracket, as illustrated in the second picture. LABEL-TAKEN SENSOR KIT, cont'd. Step-by-Step Installation Instructions, cont'd. Continued! Screw LTS assy. Fit LTS here Cable held by bracket
EasyCoder 401/501/601 – Installation Instructions 4 Step-by-Step Installation Instructions, cont'd. LABEL-TAKEN SENSOR KIT, cont'd. K Slip the cable of the label-taken sensor through the hole in the centre-line wall of the printer into the electronics compartment. K Connect the cable to P-606 on the CPU board, see below. In case of an EasyCoder 401 Linerless printer, first remove the cable to the cutter interface connector already fitted on P-606. Be car

Intermec Printer Owners Instructions: