Intermec MaxiScan 3010 Installation Manual
Read Online
Read the Intermec MaxiScan 3010 Installation Manual online using the built-in PDF viewer.
Text of the manual
3010 software version 2.00 or later
MaxiScan 3010 - Installation Guide - Version 1.2
Regulatory Statements
Intermec hereby declares that the MaxiScan 3300 has been tested and found compliant with the below listed standards as
required by the EMC Directive 89/336/EEC as amended by 92/31/EEC and by the Low Voltage Directive 73/23/EEC as
amended by 93/68/EEC:
EN55022 (1992) Class A
EN50082-2 (1995)
EN60950 (1993)
Note: This is a Class A product. In a residential environment, it may cause harmful interference. In this case the user may be required
to take appropriate measures.
USA: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
This equipment is intended for operation in an industrial environment, in compliance with the requirements for a Class A device,
pursuant to part 15 of the FCC Rules. It generates, uses and can radiate radio frequency energy. If not installed and used in
accordance with the instructions, it may cause interference to radio communications. If this equipment causes interference, the user
will be required to correct the interference at the user’s own expense.
This equipment complies with the UL 1950 standard.
Canada: This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
This equipment complies with the UL 1950 standard.
Cet équipement est conforme à la norme UL 1950.
Australia-New Zealand: This equipment has been tested and found to conform to the Australian EMC framework
concerning Class A digital devices, prescribed by the Australian and New-Zealand standard AS/NZS 3548.
Mexico: Este equipo cumple con la certificatión NOM.
The information contained in this document is for informational purposes only and is subject to change without notice. No part of this
document may be copied or reproduced in any manner without the prior written permission of Intermec Technologies Corporation.
MaxiScan products are covered by patents issued or pending in the USA and other countries.
The word Intermec, the Intermec logo, MaxiScan 3010, MaxiScan 3100, MaxiScan 3300 and EasySet are either trademarks or
registered trademarks of Intermec.
Throughout this document, trademarked names may be used. Rather than put a trademark (™ or ®) symbol in every occurrence of a
trademarked name, we state that we are using the names only in an editorial fashion, and to the benefit of the trademark owner, with
no intention of infringement.
North America / Asia Pacific / Latin America • 6001 36th Avenue West, PO Box 4280, Everett, WA 98203-9280
Tel: +1 425 348 2600 • Fax: +1 425 348 2833 • U.S. service and technical support, tel: 1 800 755 5505 • Canadian service and
technical support, tel: 1 800 688 7043
Europe / Middle East / Africa • Sovereign House, Vastern Road, Reading RG1 8BT, England
Tel: +44 (0)118 987 9400 • Fax: +44 (0)118 987 9401
Internet: http://www.intermec.com
E-mail: [email protected]
Technical information: http://datacapture.intermec.com
© 2001 Intermec Technologies Corporation. All Rights Reserved. Edition 1.2
N309
MaxiScan 3010 - Installation Guide
3
Contents
1 Before you start....................................................................................7
Introduction..................................................................................................7
Warnings .....................................................................................................7
Checklist of items for your installation .........................................................7
Installation considerations ...........................................................................8
2 Installation ............................................................................................9
MaxiScan 3010 Network System connections.............................................9
Intermec network cables............................................................................10
Cable overview
Installation configurations ..........................................................................11
MaxiScan 3100 network ............................................................................12
Up to three MaxiScan 3100 units
More than three MaxiScan 3100 units using MCS boxes
MaxiScan 3300 network ............................................................................15
Up to two MaxiScan 3300 units
More than two MaxiScan 3300 units MCS boxes
Multihead configuration .............................................................................18
Scanning area
Configuration
Input synchronization.................................................................................20
Controlled by the MaxiScan 3010
Controlled by each scanner in the network
Input synchronization examples ................................................................21
MaxiScan 3010 - Installation Guide
Input synchronization using the Maxiscan 3010 with a 5 VDC voltage
Input synchronization using the Maxiscan 3010 with other voltages
Jumper configuration
Input synchronization—serial connection through MaxiScan units
Output synchronization ............................................................................. 25
Controlled by the MaxiScan 3010
Controlled by each scanner in the network
Output synchronization example............................................................... 26
Output synchronization
3 Setup ...................................................................................................27
System configuration checklist.................................................................. 27
MaxiScan 3100 ......................................................................................... 28
Set up each MaxiScan 3100 as a slave unit – online
Setup MaxiScan 3100 slave unit – offline
MaxiScan 3300 ......................................................................................... 33
Set up each MaxiScan 3300 as a slave unit – online
Setup MaxiScan 3300 slave unit – off line
MaxiScan 3010 Network System .............................................................. 38
Set up the MaxiScan 3010 – online
MaxiScan 3010 input synchronization – setup options.............................. 40
MaxiScan 3010 output synchronization – setup options ........................... 41
4 Technical characteristics...................................................................43
Data .......................................................................................................... 43
Accessories............................................................................................... 44
MaxiScan 3010 pinouts............................................................................. 45
SCANNER BUS – 15-pin subD male connector
MaxiScan 3010 - Installation Guide
5
POWER SUPPLY – 9-pin subD male connector
HOST – 15-pin subD female connector
SYNCHROS – 9-pin subD female connector
Network cable pinouts ...............................................................................49
MaxiScan 3010 - Installation Guide
7
1
Before you start
Introduction
The MaxiScan 3010 Network System is designed to connect a network of up to 20
MaxiScan 3100 and/or 3300 scanners. This Installation Guide explains how to
install your MaxiScan 3010 and how to set up a network configuration.
Use the EasySet System setup software to set up the MaxiScan 3010 Network
System. See section 5–Setup for more details.
In this Installation Guide, unless otherwise specified, “scanner” refers to the
MaxiScan 3100 and the MaxiScan 3300.
Warnings
Do not use a standard MaxiScan power supply connected directly to the
MaxiScan 3010 Network System if you have more than two scanners in your
network—use a power supply suitable for your operating requirements (see
the power calculation method in section 2-Installation).
Always use a grounded power supply.
Always use an adapter cable to connect a MaxiScan 3100 to the MaxiScan
3010. Never connect a MaxiScan 3100 directly to the MaxiScan 3010.
Maximum current accepted between the '+' and '–' of the SYNCHROS port is
50 mA max (higher current can damage the synchronization driver !).
Checklist of items for your installation
All Systems:
MaxiScan 3010 Network System
this MaxiScan 3010 Network System Installation Guide
EasySet System setup software (on the CD ROM or can be downloaded from
the Intermec data capture web site: http://datacapture.intermec.com)
RS-485 network cable(s)
terminator connector
For part numbers
see Section 4 –
Accessories
Before you start - Installation considerations
8
MaxiScan 3010 - Installation Guide
standard MaxiScan 3300 RS-232 straight cable
MaxiScan 3100 and/or 3300 Installation Guide
Depending on your installation requirements, you may also need:
RS-232/485 adapter cable(s) (MaxiScan 3100 only)
MaxiScan Connection System (MCS) boxes
power supplies
Options:
RS-232 C "Y" cable
Installation considerations
Environment
MaxiScan 3010 Network System complies with IP51
norms. A dry and dust-protected environment is
recommended.
Setup
Use EasySet System setup software to set up your
MaxiScan Network. Test your setup before you install the
MaxiScan 3010 Network System permanently.
Cabling
• A twisted pair for data lines is strongly recommended
on the SCANNER BUS port.
• Depending on cable characteristics (twisted pair, shield,
etc.), an RS-485 connection theoretically allows a
cabling distance of a few hundred meters.
Power supply
• Always use a grounded power supply.
• A voltage between 7 and 25 VDC is required.
MaxiScan 3100
Compatible with all MaxiScan 3100 firmware versions. To
activate software synchronization you will need version
2.00 or later.
MaxiScan 3300
Compatible with MaxiScan 3300 firmware version 1.09 or
later.
For part numbers
see Section 4 –
Accessories
MaxiScan 3010 - Installation Guide
9
2
Installation
MaxiScan 3010 Network System connections
POWER
SUPPLY
SCANNER
BUS
SYNCHROS
HOST
input / output
synchronization
power supply
RS-232
host
RS-485 network
cable to scanners
How you connect up your MaxiScan 3010 Network System depends on the
number and type of scanners in the network as well as the power rating of the
power supply connected to the MaxiScan 3010.
Installation - Intermec network cables
10
MaxiScan 3010 - Installation Guide
Intermec network cables
Intermec can supply network cables with standard lengths (1m, 3m) for your
network configuration. Custom lengths can be provided on request.
These cables can provide power supply and synchronization signals to the
MaxiScan slave units on the network via the MaxiScan 3010 Network System if
required.
Each cable can be daisy-chained to another by connecting the daisy-chain end (2)
of the first cable to the MNS/daisy-chain end (3) of the second cable. The
MaxiScan end (3) is connected to the scanner or adapter cable if using a
MaxiScan 3100. Each end is labeled accordingly.
On the last cable in the network, connect the terminator connector to the daisy-
chain end (2)
Cable overview
Intermec part numbers:
– network cable 1m: 3-504039-00
– network cable 3m: 3-504039-01
– terminator connector: 3-500029-01
MaxiScan end
(DB15 male)
1
2
3
daisy-chain end
(DB15 male)
MNS/daisy-chain end
(DB15 female)
)
terminator
connector
(DB15 female)
Installation - Installation configurations
MaxiScan 3010 - Installation Guide
11
Installation configurations
There are several installation configurations possible with the MaxiScan 3010
Network System and depending on the number of scanners in the network, you
may need to use the MaxiScan Connection System (MCS boxes). Study each
case carefully to select the type of installation that best fits your needs:
MaxiScan 3100 network
•
MaxiScan 3100 network
•
MaxiScan 3100 network with MCS boxes
MaxiScan 3300 network
•
MaxiScan 3300 network
•
MaxiScan 3300 with MCS boxes
Multihead configuration
•
Multihead installation
•
Scanning area
The examples in this section are basic installation configurations. Your network may differ depending
on your needs.
Installation - MaxiScan 3100 network
12
MaxiScan 3010 - Installation Guide
MaxiScan 3100 network
The MaxiScan 3100 units are connected to the network with an RS-232/485
adapter cable. The scanners, with adapter cable, are then interconnected to the
MaxiScan 3010 Network System through an RS-485 network cable.
All MaxiScan 3100 share the same power supply and I/O synchronization lines.
Installation - MaxiScan 3100 network
MaxiScan 3010 - Installation Guide
13
Up to three MaxiScan 3100 units
adapter cable
P/N 3-510022-00
adapter cable
P/N 3-510022-00
MaxiScan 3010
RS-232 straight cable
P/N 0-530062-01
RS-485 network cable
1m P/N 3-504039-00
3m P/N 3-504039-01
MaxiScan 3100
terminator connector
P/N 3-500029-01
MaxiScan 3100
power supply
7 – 25V
If you are using a standard MaxiScan power supply (15 V), you can only connect
up to three MaxiScan 3100 units to the MaxiScan 3010 Network System.
If you want to connect more than three scanners, you must use the alternative
connection method using the MaxiScan Connection System described on the next
page or provide a power supply with sufficient power calculated as follows:
The power supply must withstand at least (n x 2.5 Watt) with peaks of up to two or three times this value
(n = number of MaxiScan 3100 scanners connected).
The value obtained does not take into account other external devices (synchronization devices, etc.) that may be
connected to the MaxiScan 3010 Network System.
Warning: Power supply must be between 7 and 25 V.
Installation - MaxiScan 3100 network
14
MaxiScan 3010 - Installation Guide
More than three MaxiScan 3100 units using MCS boxes
The MaxiScan 3100 units are connected to their respective standard MaxiScan
Connection System (MCS) boxes through an RS-232/485 adapter cable. All
standard MCS boxes are then interconnected to the MaxiScan 3010 Network
System through an RS-485 network cable.
Each scanner has its own power supply and manages its own I/O synchronization
lines via the MCS boxes.
adapter cable
P/N 3-510022-00
adapter cable
P/N 3-510022-00
power supply
7 – 25V
MCS
MaxiScan 3010
RS-232 straight cable
P/N 0-530062-01
RS-485 network cable
1m P/N 3-504039-00
3m P/N 3-504039-01
power supply and
I/O synchros
MaxiScan 3100
MCS
power supply and
I/O synchros
MaxiScan 3100
terminator connector
P/N 3-500029-01
MCS boxes must be used when connecting more than three MaxiScan 3100 units in your network.
Installation - MaxiScan 3300 network
MaxiScan 3010 - Installation Guide
15
MaxiScan 3300 network
The MaxiScan 3300 units are directly interconnected to the MaxiScan 3010
Network System through an RS-485 network cable.
All scanners share the same power supply and I/O synchronization lines.
Installation - MaxiScan 3300 network
16
MaxiScan 3010 - Installation Guide
Up to two MaxiScan 3300 units
RS-232 straight cable
P/N 530062-01
MaxiScan 3300
MaxiScan 3300
MaxiScan 3010
RS-485 network cable
1m P/N 3-504039-00
3m P/N 3-504039-01
terminator connector
P/N 3-5300029-01
power supply
7 – 25 V
If you are using a standard MaxiScan power supply (15 V), you can only connect
up to two MaxiScan 3300 units to the MaxiScan 3010 Network System.
If you want to connect more than two scanners, you must use the alternative
connection method using the MaxiScan Connection System described on the next
page or provide a power supply with sufficient power calculated as follows:
The power supply must withstand at least (n x 5 Watt) with peaks of up to two or three times this value
(n = number of MaxiScan 3300 scanners connected).
The value obtained does not take into account other external devices (synchronization devices, etc.) supplied by
the MaxiScan 3010 Network System power unit.
Warning: Power supply must be between 7 and 25 V.
Installation - MaxiScan 3300 network
MaxiScan 3010 - Installation Guide
17
More than two MaxiScan 3300 units MCS boxes
The MaxiScan 3300 units are connected to their respective standard MaxiScan
Connexion System (MCS) boxes. All standard MCS boxes are then
interconnected to the MaxiScan 3010 Network System through an RS-485 network
cable.
Each MaxiScan has its own power supply and manages its own I/O
synchronization lines.
power supply
7 – 25 V
MCS
MaxiScan 3010
RS-232 straight cable
P/N 0-530062-01
RS-485 network cable
1m P/N 3-504039-00
3m P/N 3-504039-01
MaxiScan 3300
standard power
supply and
I/O synchros
terminator connector
P/N 3-500029-01
MaxiScan 3300
MCS
standard power
supply and
I/O synchros
MCS boxes must be used when connecting more than (#) MaxiScan 3300 units in your network.
Installation - Multihead configuration
18
MaxiScan 3010 - Installation Guide
Multihead configuration
Multihead is a way of combining several MaxiScan 3100 or MaxiScan 3300 units to
cover a larger scanning area.
RS-232 straight cable
P/N 0-530062-01
scanner # 2
scanner # 1
MaxiScan 3010
RS-485 network cable
1m P/N 3-504039-00
3m P/N 3-504039-01
terminator connector
P/N 3-500029-01
synchronization
Power supply
7 – 25 V
Installation - Multihead configuration
MaxiScan 3010 - Installation Guide
19
Scanning area
C3
overlap
C2
C1
scanner
n°2 (M2)
scanner
n°1(M1)
time period
Overlap: Zone covered by at least 2 scanners. In this example, both scanners (M1
and M2) can read the same bar code (C3).
To avoid transmitting the same code twice, data read by both scanners within a
specified period of time is checked and filtered by the MaxiScan 3010. This is the
multihead timeout that must be defined during setup with EasySet. The bar code
read twice will only be transmitted one time.
M1
M2
M2
M1
M2
C1
C3
C2
C3
C3
Start
timeout
End
timeout
Start
timeout
collected
collected
collected
collected
collected
transmitted
transmitted
transmitted
NOT
transmitted
transmitted
Configuration
In a multihead network configuration, you will need to use EasySet to set up
multihead mode and to define the multihead timeout. See section 3 – Setup for
more information
Installation - Input synchronization
20
MaxiScan 3010 - Installation Guide
Input synchronization
With the MaxiScan 3010 Network System, input synchronization can be controlled
directly by the MaxiScan 3010 or individually by each scanner in the network.
Controlled by the MaxiScan 3010
The synchronization device is connected to the SYNCHROS port on the MaxiScan
3010 or a message is sent to the MaxiScan 3010 by the host system.
Controlled by each scanner in the network
Input synchronization can be controlled individually by each scanner in the
network. The synchronization device can be connected to the MCS box (if
applicable) or directly to the MaxiScan 3010 (see examples).
Refer to the MaxiScan 3100 and/or 3300 Installation Guide for a detailed
explanation of how to set up synchronization for the scanners in your network.
When input synchronization is controlled individually by each MaxiScan unit, you only need to
configure the scanners in the network, not the MaxiScan 3010.
Installation - Input synchronization examples
MaxiScan 3010 - Installation Guide
21
Input synchronization examples
Input synchronization using the Maxiscan 3010 with a 5 VDC voltage
Example: Reading triggered by an opto-coupled MLV 40-8/28 (VISOLUX) cell.
photoelectric
sensor
1 5
4
9 8 7 6
5 4 3 2 1
GND
SI-
SI+ +5V (50 mA max)
7-25 VDC power supply
300 ΩΩΩΩ
SYNCHROS 9-pin subD
female connector
MaxiScan 3010
Pin 7 brings the SI+ signal to the MaxiScan 3010.
In all cases, the synchronization current provided by the external input device must be limited
to 20 mA max (15 mA is a good average value).
Installation - Input synchronization examples
22
MaxiScan 3010 - Installation Guide
Input synchronization using the Maxiscan 3010 with other voltages
Example: Reading triggered by an opto-coupled MLV 40-8/28 (VISOLUX) cell.
photoelectric
sensor
1 5
4
9 8 7 6
5 4 3 2 1
GND
SI- SI+
7-25 VDC power supply
SYNCHROS 9-pin subD
female connector
MaxiScan 3010
300Ω
1KΩ
2.2KΩ
S4
S5
S6
300Ω
Pin 8 brings the SI+ signal to the MaxiScan 3010 in an adjustable configuration of resistors (via 3
jumpers) for different voltage inputs.
In all cases, the synchronization current provided by the external input device must be limited
to 20 mA max (15 mA is a good average value).
Installation - Input synchronization examples
MaxiScan 3010 - Installation Guide
23
Jumper configuration
To reconfigure the jumpers, unscrew the front and rear panels of the MaxiScan 3010 and slide out the
motherboard.
VOLTAGE
JUMPER
6 to 15V
S4
16 to 24V
S5
25 to 50V *
S6
POWER SUPPLY
DB9 male
SCANNER BUS
DB15 male
SYNCHROS
DB9 female
HOST
DB15 female
S6 S5 S4
* The SI+ signal on the SYNCHROS port accepts up to 50V, however the MaxiScan 3010 is limited to
25V.
Installation - Input synchronization examples
24
MaxiScan 3010 - Installation Guide
Input synchronization—serial connection through MaxiScan units
Example: Reading triggered by an opto-coupled MLV 40-8/28 (VISOLUX) cell.
terminator connector
P/N 3-500029-01
SI-
SI-
SI-
SI+
SI+
SI+
photoelectric
sensor
1 5
4
9 8 7 6
5 4 3 2 1
GND
SI- SI+ +5V (50 mA max)
7-25 VDC
power supply
SYNCHROS 9-pin subD
female connector
MaxiScan 3010
15 14 13 12 11 10 9
8 7 6 5 4 3 2 1
SCANNER BUS 15-pin
subD male connector
Pin 4 brings the SI+ signal to the SCANNER BUS port only. This is only possible for a maximum of
three or four scanners using the correct power supply (see the power calculation method in section 2-
Installation). In this example, the synchronization is controlled by each scanner and not by the
MaxiScan 3010. The synchronization parameters of each scanner must be configured separately. The
synchronization parameters are not activated in the MaxiScan 3010.
This is an example of what can be done using two network cables and a terminator connector.
In all cases, the synchronization current provided by the external input device must be limited
to 20 mA max (15 mA is a good average value).
Installation - Output synchronization
MaxiScan 3010 - Installation Guide
25
Output synchronization
With the MaxiScan 3010 Network System, output synchronization can be
controlled directly by the MaxiScan 3010 or individually by each scanner in the
network.
Controlled by the MaxiScan 3010
The MaxiScan 3010 can send information to an external device or directly to the
host system after a good read, no read or network failure.
Controlled by each scanner in the network
Output synchronization can also be controlled individually by each scanner in the
network. To setup this type of output synchronization, see the MaxiScan 3100 and
MaxiScan 3300 Installation Guides.
When output sychronization is controlled by each scanner, there is no need to activate output
sychronization in the MaxiScan 3010.
Installation - Output synchronization example
26
MaxiScan 3010 - Installation Guide
Output synchronization example
Output synchronization
Example: Opto-coupled control output.
9 8 7 6
5 4 3 2 1
GND SO- SO+ +5V (50 mA max)
7-25 VDC power supply
MaxiScan 3100
SYNCHROS 9-pin subD
female connector
conveyor
command block
The synchronization current provided by the external output device must be limited to 20 mA
max (15 mA is a good average value)..
MaxiScan 3010 - Installation Guide
27
3
Setup
System configuration checklist
To operate in a network configuration, each scanner (slave unit) has its own ID
number and is polled periodically for network data collection.
System configuration basically comprises the following steps:
Configure the scanners for the network as slave units (online or offline
setup)– each slave unit must have its own ID number.
Configure the MaxiScan 3010 Network System (online setup)–parameters
include the number of slave units in the network, RS-232 settings for
communication with the host system, etc.
Disconnect all power supplies.
Using the network cables, connect the slave units to the MaxiScan 3010
directly on the SCANNER BUS port (or via the MCS boxes if applicable),
connect the HOST cable, and connect the SYNCHROS cable if applicable.
Connect the slave unit power supplies to the MCS boxes if applicable.
Connect the MaxiScan 3010 power supply and I/O synchronization device if
applicable.
IMPORTANT: Before setting up the MaxiScan Network System, you must first configure each
MaxiScan 3100 and 3300 unit that will be used in the network. See the “MaxiScan 3100” and
“MaxiScan 3300 Installation Guide” for the correct procedure.
Setup - MaxiScan 3100
28
MaxiScan 3010 - Installation Guide
MaxiScan 3100
Set up each MaxiScan 3100 as a slave unit – online
System power OFF
Connect the MaxiScan 3100 slave unit to the PC where EasySet is installed.
There are two options for this connection depending on the cable used:
power supply
RS-232 straight cable
P/N 0-530062-01
MCS box
power supply
RS-232 « Y » cable
P/N 0-530062-02
System power ON
Read this configuration code with the MaxiScan 3100 to enable online setup
with EasySet:
EasySet
MaxiScan 3100 – start online setup
41\4A\0F\29\60\4F
Setup - MaxiScan 3100
MaxiScan 3010 - Installation Guide
29
Start EasySet and select MaxiScan 3100
from the menu Product > Select.
If you have not already set up your scanner(s),
do it now. See the MaxiScan 3100 Installation Guide for details on configuring the
MaxiScan 3100.
You must configure your scanner(s) before activating each of them as a
slave unit.
In EasySet, activate synchronization if applicable (firmware version 2.00 or
later). This activates synchronization controlled by the MaxiScan 3010.
network parameters > activate synchronization
To set up synchronization controlled by the scanners in your network, see the
MaxiScan 3100 Installation Guide for details.
Activate each MaxiScan 3100 as a slave unit.
You can activate up to 20 slaves with EasySet.
network parameters > activate slave
Disconnect then reconnect the scanner to put it in to working mode. If you need to re-establish
communication with EasySet, read the "start online setup" bar code on the previous page.
Deactivating slave mode – online
You can deactivate each slave unit on line with EasySet.
network parameters > deactivate slave 3100
Setup - MaxiScan 3100
30
MaxiScan 3010 - Installation Guide
Setup MaxiScan 3100 slave unit – offline
You can use EasySet to print out configuration bar codes for offline setup.
Here are some basic configuration bar codes to configure up to 5 MaxiScan 3100
slave units. The EasySet software provides the full set of configuration options to
configure up to 20 MaxiScan units.
Only read this code if you want to reset factory defaults!
Do not read this code if you have already set up each MaxiScan unit.
reset factory defaults (optional)
\46\42\60
If you have not already configured your MaxiScan 3100 unit(s), do it now. See the
MaxiScan 3100 Installation Guide for details.
You must configure your scanner(s) before activating each of them as a
slave unit.
Read this code to activate synchronization controlled by the MaxiScan 3010:
This option is available only for MaxiScan 3100 units containing software version
2.00 or later.
Activate synchronization mode – MaxiScan 3100
\4B\5A\00\3E\01\4B\5A\01\3E\04\4B\59\01\60
To set up synchronization controlled by the MaxiScan 3100, see the MaxiScan
3100 Installation Guide.
Setup - MaxiScan 3100
MaxiScan 3010 - Installation Guide
31
Read these bar codes to activate the MaxiScan 3100 slave units:
activate slave – MaxiScan 3100 – slave 1
\41\4A\0F\2A\47\04\02\01\60
activate slave – MaxiScan 3100 – slave 2
\41\4A\0F\2A\47\04\02\02\60
activate slave – MaxiScan 3100 – slave 3
\41\4A\0F\2A\47\04\02\03\60
activate slave – MaxiScan 3100 – slave 4
\41\4A\0F\2A\47\04\02\04\60
Setup - MaxiScan 3100
32
MaxiScan 3010 - Installation Guide
activate slave – MaxiScan 3100 – slave 5
\41\4A\0F\2A\47\04\02\05\60
Disconnect then reconnect the scanner to put it in to working mode. The start online setup bar code
on the previous page will put the scanner back in to setup mode.
Deactivating slave mode – offline
Read this bar code to deactivate each slave unit:
deactivate slave – 3100
\41\4A\01\24\60
Setup - MaxiScan 3300
MaxiScan 3010 - Installation Guide
33
EasySet
MaxiScan 3300
Set up each MaxiScan 3300 as a slave unit – online
System power OFF
Connect the MaxiScan 3300 slave unit to the PC where EasySet is installed.
There are two options for this connection depending on the cable used:
power supply
RS-232 straight cable
P/N 0-530062-01
MCS box
power supply
RS-232 « Y » cable
P/N 0-530062-02
System power ON
Start EasySet and select MaxiScan 3300 from the menu Product > Select.
Set the communication parameters automatically by selecting the menu
communication > setup.
Setup - MaxiScan 3300
34
MaxiScan 3010 - Installation Guide
In EasySet, activate synchronization if applicable. This activates
synchronization controlled by the MaxiScan 3010.
network parameters > activate synchronization
To set up synchronization controlled by the scanners in your network, see the
MaxiScan 3300 Installation Guide for details.
Activate each MaxiScan 3300 as a slave unit.
You can activate up to 20 slaves with EasySet.
network parameters > activate slave
Once the scanner has been activated as a slave, communication between the MaxiScan 3300 and
EasySet is cut off. You must activate the slaves at the end of setup.
Deactivating slave mode – online
Since there is no communication between the MaxiScan 3300 and EasySet when
slave mode has been activated, you must read this badge to deactivate each slave
unit:
deactivate slave unit – 3300
\48\47\00\48\3E\00\47\3E\00\40\4F\45\53\3E\00\45\54\3E\0D\3E\0A\45\58\60
Setup - MaxiScan 3300
MaxiScan 3010 - Installation Guide
35
Setup MaxiScan 3300 slave unit – off line
You can use EasySet to print out configuration bar codes for offline setup.
Here are some basic configuration bar codes to configure up to 5 3300 slave units.
The EasySet software provides the full set of configuration options to configure up
to 20 MaxiScan units.
Only read this code if you want to reset factory defaults!
Do not read this code if you have already set up each MaxiScan unit.
reset factory defaults (optional)
\46\42\60
If you have not already configured your MaxiScan 3300 unit(s), do it now. See the
MaxiScan 3100 Installation Guide for details.
You must configure your scanner(s) before activating each of them as a
slave unit.
Read this code to activate synchronization controlled by the MaxiScan 3010:
Activate synchronization software - 3300
\4B\5A\00\3E\01\4B\5A\01\3E\04\4B\59\01\4A\5F\00\60
To set up synchronization controlled by the MaxiScan 3300, see the MaxiScan
3300 Installation Guide.
Setup - MaxiScan 3300
36
MaxiScan 3010 - Installation Guide
Read these bar codes to activate the MaxiScan 3300 slave units:
activate slave – MaxiScan 3300 – slave 1
\48\47\01\40\43\46\00\48\3E\06\49\3E\15\41\08\40\4E\45\53\3E\02\45\54\3E\03\47\04\02\01\45\57\60
activate slave – MaxiScan 3300 – slave 2
\48\47\01\40\43\46\00\48\3E\06\49\3E\15\41\08\40\4E\45\53\3E\02\45\54\3E\03\47\04\02\02\45\57\60
activate slave – MaxiScan 3300 – slave 3
\48\47\01\40\43\46\00\48\3E\06\49\3E\15\41\08\40\4E\45\53\3E\02\45\54\3E\03\47\04\02\03\45\57\60
Setup - MaxiScan 3300
MaxiScan 3010 - Installation Guide
37
activate slave – MaxiScan 3300 – slave 4
\48\47\01\40\43\46\00\48\3E\06\49\3E\15\41\08\40\4E\45\53\3E\02\45\54\3E\03\47\04\02\04\45\57\60
activate slave – MaxiScan 3300 – slave 5
\48\47\01\40\43\46\00\48\3E\06\49\3E\15\41\08\40\4E\45\53\3E\02\45\54\3E\03\47\04\02\05\45\57\60
Deactivating slave mode – offline
Read this bar code to deactivate each slave unit:
deactivate slave unit – 3300
\48\47\00\48\3E\00\47\3E\00\40\4F\45\53\3E\00\45\54\3E\0D\3E\0A\45\58\60
Setup - MaxiScan 3300
38
MaxiScan 3010 - Installation Guide
MaxiScan 3010 Network System
Set up the MaxiScan 3010 – online
System power OFF
Connect the MaxiScan 3010 Network System to the PC where EasySet is
installed
power supply
7 – 25 V
RS-232 straight cable
P/N: 0-530062-01
MaxiScan 3010
Start EasySet
EasySet
System power ON
When the power is switched on, the MaxiScan 3010 is in configuration mode
(19200, 8, N, 2) and remains in this mode until it receives data from a MaxiScan
unit on the network (when a scanner reads a bar code). Once it has read a bar
code the MaxiScan goes in to default configuration (9600, 7, E, 2).
Set up the MaxiScan 3010 Network System using EasySet:
• number of slaves (scanners) in the network (default = 10)
• time of polling delay between slaves
Setup - MaxiScan 3300
MaxiScan 3010 - Installation Guide
39
• preambles or postambles for the MaxiScan 3010 or for each slave. Pre
and postambles for the slaves allow the host application to discern data
coming from one scanner or another.
• multihead function
• synchronization (see synchronization setup options on the following page)
• multicode function
See EasySet for a full explanation of the setup options for the MaxiScan 3010.
Setup - MaxiScan 3010 input synchronization – setup options
40
MaxiScan 3010 - Installation Guide
MaxiScan 3010 input synchronization – setup options
Reading can be triggered by an external device (opto-coupled cell, automated
machine, electrical control device, etc.) connected to the MaxiScan 3010 or by a
message from the host system.
The Intermec photoelectric switch (P/N 3-500029-03) is fully compatible with the MaxiScan 3010 input
synchronization port.
Trigger event
Current on
Reading is active when current flows between the MaxiScan 3010
inputs SI+ and SI-. Reading remains active until the current stops
flowing.
Current off
Reading is active when no current flows between the MaxiScan
3010 inputs SI+ and SI-. Reading remains active until current starts
to flow.
Rising edge
Reading is triggered by a rising edge current between the MaxiScan
3010 inputs SI+ and SI-. Reading remains active until the input
synchronization timeout is reached.
Falling edge
Reading is triggered by a falling edge current between the
MaxiScan 3010 inputs SI+ and SI-. Reading remains active until the
input synchronization timeout is reached.
Rising or
falling edge
Reading is triggered by a rising or falling edge current between the
MaxiScan 3010 inputs SI+ and SI-. Reading remains active until
the input synchronization timeout is reached.
Software
Reading is triggered when the MaxiScan 3010 receives a start read
character from the host system. Reading remains active until a stop
read character is received.
Setup - MaxiScan 3010 output synchronization – setup options
MaxiScan 3010 - Installation Guide
41
MaxiScan 3010 output synchronization – setup options
Trigger event
Good read
The output device is triggered by a good read.
No read
The output device is triggered when a scanner in the network does
not perform a good read within a given period of time. Only works
with an input synchronization trigger.
Network
failure
The output device is triggered when a problem occurs on the
network protocol (bad frame, bad CRC etc.).
Current on
The output device operates when current flows between the
MaxiScan 3010 outputs SO+ and SO-.
Current off
The output device operates when no current flows between the
MaxiScan 3010 outputs SO+ and SO-.
Software
The MaxiScan 3010 can send a message to the host system after
a good read, no read or network failure.
MaxiScan 3010 - Installation Guide
43
4
Technical characteristics
Data
Supported products
• MaxiScan 3100
• MaxiScan 3300
Network capacity
up to 20 MaxiScan slave units
Host system interface
RS-232 C (default = 9600, 7, E, 2)
Interface
I/O synchronization
one input sync from external device
one output sync to external device
Power requirements
7-25 VDC ± 5%
Electrical
characteristics
Current consumption
0.675 W, peaks of up to 2 or 3 times this value at
power-up
Dimensions (width x depth x height)
14.2 x 11.3 x 3 cm (5.59 x 4.45 x 1.18")
Weight
300 grams (10.6 ounces)
Physical
characteristics
Connectors
DB9 and DB15 connectors
Operating temperature
0°C to 40°C (32°F to 104°F)
Storage temperature
-25°C to 60°C (-13°F to 140°F)
Relative humidity
10% to 90% non-condensing
Electrostatic discharge
CE approved
Shock resistance
Withstand 5 drops from 1m high on concrete floor
Sealing (dust etc.)
IP51
Environmental
specifications
MTBF
> 50 000 hours
Technical characteristics - Accessories
44
MaxiScan 3010 - Installation Guide
Accessories
standard MaxiScan 3300 RS-232 cable
0-530062-01
1 m network cable
3-504039-00
3 m network cable
3-504039-01
terminator connector
adapter cable (MaxiScan 3100 only)
RS-232 C "Y" cable
3-500029-01
3-510022-00
0-530062-02
Cables
The MaxiScan 3010 must have a grounded power supply.
Use shielded cables for the SCANNER BUS line. A twisted pair is
recommended for data lines on the SCANNER BUS port.
US
0-531029-08
Europe (except UK)
0-531029-02
Power supply
UK
0-531029-04
Sync switch
Intermec photoelectric switch
3-500029-03
Technical characteristics - MaxiScan 3010 pinouts
MaxiScan 3010 - Installation Guide
45
MaxiScan 3010 pinouts
SCANNER BUS – 15-pin subD male connector
7-25 VDC GND 7-25 VDC PWR
Sheild
9 10 11 12 13 14 15
1 2 3 4 5 6 7 8
SI+ SI-
RS-422 / 485 RX- TX- RX+ TX+
pin
function
1
receive data RX- (RS-422 / 485)
2
transmit data TX- (RS-422 / 485)
3
receive data RX+ (RS-422 / 485)
4
transmit data TX+ (RS-422 / 485)
5
positive synchronization input (SI+)
6
negative synchronization input (SI-)
7
not connected
8
not connected
9
power in (7 to 25 VDC)
10
power in (7 to 25 VDC)
11
power ground
12
shield
13
grounded power
14
power in (7 to 25 VDC)
15
power ground
Technical characteristics - MaxiScan 3010 pinouts
46
MaxiScan 3010 - Installation Guide
POWER SUPPLY – 9-pin subD male connector
6 7 8 9
1 2 3 4 5
GND (4 wires)
7-25 VDC (5 wires)
pin
function
1
power in (7 to 25 VDC)
2
power in (7 to 25 VDC)
3
power in (7 to 25 VDC)
4
power in (7 to 25 VDC)
5
power in (7 to 25 VDC)
6
power ground
7
power ground
8
power ground
9
power ground
Technical characteristics - MaxiScan 3010 pinouts
MaxiScan 3010 - Installation Guide
47
HOST – 15-pin subD female connector
RTS CTS TX RX
GND
15 14 13 12 11 10 9
8 7 6 5 4 3 2 1
pin
function
1
receive data (RS-232 C)
2
transmit data (RS-232 C)
3
clear to send (RS-232 C)
4
request to send (RS-232 C)
5
not connected
6
not connected
7
not connected
8
reserved
9
reserved
10
reserved
11
reserved
12
reserved
13
signal ground (RS-232 C)
14
reserved
15
reserved
Technical characteristics - MaxiScan 3010 pinouts
48
MaxiScan 3010 - Installation Guide
SYNCHROS – 9-pin subD female connector
In all cases, the synchronization current provided by the external input/output
device must be limited to 20 mA max (15 mA is a good average value) !
9 8 7 6
5 4 3 2 1
SI- SI+ SO- SO+ +5V
7-25V
pwr
GND
RTN
ADJ
SI+
SI+
pin
function
1
+5 VDC out (65 mA max)
2
positive synchronization output (SO+) (50 mA max )
3
negative synchronization output (SO-) (50 mA max)
4
RETURN positive synchronization input (SI+) (50
mA max)
brings the SI+ signal to the SCANNER BUS port only
(serial connection to slaves with MaxiScan 3010
network cables)
5
negative synchronization input (SI-) (50 mA max)
6
7-25 VDC 10 Watt
7
MaxiScan 3010 positive synchronization input (SI+)
(50mA max)
brings the SI+ signal to MaxiScan 3010 only
8
Adjustable MaxiScan 3010 positive synchronization
input (SI+) (50 mA max)
brings the SI+ signal to MaxiScan 3010 only with
adjustable resistors configuration
9
power ground
Technical characteristics - Network cable pinouts
MaxiScan 3010 - Installation Guide
49
Network cable pinouts
Network cable (1 m or 3 m)
6 Si-
5 Si+
Sub D 15-position male
with threaded inserts
with female screwlocks
(UNC 4-40)
IP65-compliant
1 RS485-
4 RS485+
3 RS485+
2 RS485-
10 Vin
11 GND
scanner
12 Shield
13 GND
14 Vin
2 RS485-
6 Si-
5 Si+
4 RS485+
9 Vin (7-25V)
10 Vin (7-25V)
11 GND
daisy chain
12 Body P3
13 GND
14 Vin (7-25V)
15 GND
Sub D 15-position male
with threaded inserts
with female screwlocks
(UNC 4-40)
IP65-compliant
twisted pair
twisted pair
Sub D 15-position
female with screws
terminator
connector
2
Si-
6
Si+
5
4
9
10
11
12
13
14
15
terminator connector