Taylor 161 Operator's Manual
Text of the manual
Soft Serve Freezer
Original Operating Instructions
055155-M
8/14/08 (Original Publication)
(Updated 7/8/14)
Complete this page for quick reference when service is required:
Taylor Distributor:
Address:
Phone:
Service:
Parts:
Date of Installation:
Information found on the data label:
Model Number:
Serial Number:
Electrical Specs:
Voltage
Cycle
Phase
Maximum Fuse Size:
A
Minimum Wire Ampacity:
A
E 2008 Carrier Commercial Refrigeration, Inc.
055155-M
Any unauthorized reproduction, disclosure, or distribution of copies by any person of any portion of this work may be
a violation of Copyright Law of the United States of America and other countries, could result in the awarding of Statutory
Damages of up to $250,000 (17 USC 504) for infringement, and may result in further civil and criminal penalties.
All rights reserved.
Taylor Company
a division of Carrier Commercial Refrigeration, Inc.
750 N. Blackhawk Blvd.
Rockton, IL
61072
Table of Contents
Model 161
Table of Contents
Section 1
To the Installer
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installer Safety
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Site Preparation
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air Cooled Units
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Water Connections (Water Cooled Units Only)
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Connections
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Hook- Up Installation
(60 Cycle, 1 Ph, Supplied With Cord and Plug)
3
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Section 2
To the Operator
4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Section 3
Safety
5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Section 4
Operator Parts Identification
7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model 161
7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Beater Door Assembly
8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Section 5
Important: To the Operator
10
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Symbol Definitions
10
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Section 6
Operating Procedures
14
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Assembly
14
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sanitizing
17
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Priming
19
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Closing Procedure
19
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Draining Product From the Freezing Cylinder
19
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rinsing
20
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cleaning
20
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disassembly
20
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Brush Cleaning
20
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table of Contents
Table of Contents - Page 2
Section 7
Important: Operator Checklist
22
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
During Cleaning and Sanitizing
22
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting Bacterial Count
22
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Regular Maintenance Checks
22
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Winter Storage
23
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Section 8
Troubleshooting Guide
24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Section 9
Parts Replacement Schedule
27
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Section 10
Limited Warranty on Equipment
28
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Section 11
Limited Warranty on Parts
30
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Section 12
Parts List
33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring Diagrams
42
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Note: Continuing research results in steady improvements; therefore, information
in this manual is subject to change without notice.
Note: Only instructions originating from the factory or its authorized translation
representative(s) are considered to be the original set of instructions.
E 2008 Carrier Commercial Refrigeration, Inc. (Original Publication)
(Updated July, 2014)
055155- M
Any unauthorized reproduction, disclosure, or distribution of copies by any person of any portion of this work
may be a violation of Copyright Law of the United States of America and other countries, could result in the
awarding of Statutory Damages of up to $250,000 (17 USC 504) for infringement, and may result in further
civil and criminal penalties.
All rights reserved.
Taylor Company
a division of Carrier Commercial Refrigeration, Inc.
750 N. Blackhawk Blvd.
Rockton, IL
61072
To the Installer
131122
Section 1
To the Installer
The following information has been included in the
manual as safety and regulatory guidelines. For
complete installation instructions, please see the
Installation Checklist.
Installer Safety
In all areas of the world, equipment should be
installed in accordance with existing local codes.
Please contact your local authorities if you have any
questions.
Care should be taken to ensure that all basic safety
practices are followed during the installation and
servicing activities related to the installation and
service of Taylor equipment.
S
Only authorized Taylor service personnel
should perform installation and repairs on the
equipment.
S
Authorized service personnel should consult
OSHA
Standard
29CFRI910.147
or
the
applicable code of the local area for the
industry
standards
on
lockout/tagout
procedures before beginning any installation
or repairs.
S
Authorized service personnel must ensure
that the proper PPE is available and worn
when required during installation and service.
S
Authorized service personnel must remove all
metal jewelry, rings, and watches before
working on electrical equipment.
The main power supply(s) to the freezer must
be disconnected prior to performing any repairs.
Failure to follow this instruction may result in personal
injury or death from electrical shock or hazardous
moving parts as well as poor performance or damage
to the equipment.
Note: All repairs must be performed by an
authorized Taylor Service Technician.
This unit has many sharp edges that can
cause severe injuries.
Site Preparation
Review the area where the unit will be installed before
uncrating the unit. Make sure that all possible hazards
to the user and the equipment have been addressed.
For Indoor Use Only: This unit is designed to operate
indoors, under normal ambient temperatures of
70_-75_F (21_-24_C). The freezer has successfully
performed
in
high
ambient
temperatures
of
104_(40_C) at reduced capacities.
This unit must NOT be installed in an area
where a water jet or hose can be used. NEVER use a
water jet or hose to rinse or clean the unit. Failure to
follow this instruction may result in electrocution.
This unit must be installed on a level surface
to avoid the hazard of tipping. Extreme care should be
taken in moving this equipment for any reason. Two or
more persons are required to safely move this unit.
Failure to comply may result in personal injury or
equipment damage.
Uncrate the unit and inspect it for damage. Report any
damage to your Taylor Distributor.
This piece of equipment is made in the USA and has
USA sizes of hardware. All metric conversions are
approximate and vary in size.
Air Cooled Units
DO NOT obstruct air intake and discharge openings:
The Model 161 requires 6” (152 mm) on both sides,
and 0” at the rear. Install the skirt provided on the right
side of the unit. Minimum air clearances must be met
to assure adequate air flow for optimum performance.
To the Installer
130319
Water Connections
(Water Cooled Units Only)
An adequate cold water supply must be provided with
a hand shut- off valve. On the underside rear of the
base pan, two 3/8” I.P.S. water connections for inlet
and outlet have been provided for easy hook- up. 1/2”
inside diameter water lines should be connected to the
machine. (Flexible lines are recommended, if local
codes permit.) Depending on local water conditions, it
may be advisable to install a water strainer to prevent
foreign substances from clogging the automatic water
valve. There will be only one water “in” and one water
“out” connection. DO NOT install a hand shut- off valve
on the water “out” line! Water should always flow in this
order: first, through the automatic water valve; second,
through the condenser; and third, through the outlet
fitting to an open trap drain.
A back flow prevention device is required
on the incoming water connection side. Please
refer to the applicable National, State, and local codes
for determining the proper configuration.
Electrical Connections
Each unit requires one power supply for each data
label on the unit. Check the data label(s) on the freezer
for branch circuit overcurrent protection or fuse, circuit
ampacity, and other electrical specifications. Refer to
the wiring diagram provided inside of the electrical box
for proper power connections.
In the United States, this equipment is intended to be
installed in accordance with the National Electrical
Code (NEC), ANSI/NFPA 70- 1987. The purpose of
the NEC code is the practical safeguarding of persons
and property from hazards arising from the use of
electricity. This code contains provisions considered
necessary for safety. Compliance therewith and
proper maintenance will result in an installation
essentially free from hazard!
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
This
unit
is
provided
with
an
equipotential
grounding lug that is to be properly attached to the rear
of the frame by the authorized installer. The installation
location is marked by the equipotential bonding
symbol (5021 of IEC 60417-1) on both the removable
panel and the equipment’s frame.
S
Stationary appliances which are not equipped
with a power cord and a plug or another device
to disconnect the appliance from the power
source must have an all-pole disconnecting
device with a contact gap of at least 3 mm
installed in the external installation.
S
Appliances that are permanently connected to
fixed wiring and for which leakage currents
may
exceed
10
mA,
particularly
when
disconnected or not used for long periods, or
during initial installation, shall have protective
devices such as a GFI, to protect against the
leakage of current, installed by the authorized
personnel to the local codes.
S
Supply cords used with this unit shall be
oil-resistant,
sheathed
flexible
cable
not
lighter than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(Code designation 60245 IEC 57) installed
with the proper cord anchorage to relieve
conductors from strain, including twisting, at
the terminals and protect the insulation of the
conductors from abrasion.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent, or similarly qualified person, in order to
avoid a hazard.
To the Installer
120529
Electrical Hook- Up Installation
(60 Cycle, 1 Ph, Supplied With Cord and Plug)
This freezer is supplied with a 3- wire cord and
grounding type plug for connection to a single phase,
60 cycle, branch circuit supply. This unit must be
plugged into a properly grounded receptacle. The cord
and plug provided for 208/230/60/1, is 20A; therefore
the wall outlet must also be 20A. Check the data label,
located on the side panel, for electrical specifications.
Permanent wiring may be employed if required by local
codes. Instructions for conversion to permanent wiring
are as follows:
1.
Be sure the freezer is electrically disconnected.
2.
Remove the appropriate panel and locate the
small electrical box at the base of the freezer.
3.
Remove the factory- installed cord and strain
relief bushing.
4.
Route incoming permanent wiring through 7/8”
(22 mm) hole in base pan.
5.
Connect two power supply leads. Attach ground
(earth) wire to the grounding lug inside the
electrical box.
6.
Be sure the unit is properly grounded before
applying power.
Beater Rotation
Beater rotation must be clockwise as viewed
looking into the freezing cylinder.
Note: The
following
procedures
should
be
performed by a trained service technician.
To correct rotation on a three- phase unit, interchange
any two incoming power supply lines at freezer main
terminal
block
only.
To
correct
rotation
on
a
single- phase unit, change the leads inside the beater
motor. (Follow diagram printed on motor.)
Electrical connections are made directly to the
terminal block provided in the splice boxes which are
mounted mid- level on the frame channel on the sides
of the freezer.
Refrigerant
In consideration of our environment, Taylor
uses only earth friendly HFC refrigerants. The HFC
refrigerant used in this unit is R404A. This refrigerant
is generally considered non-toxic and non-flammable,
with an Ozone Depleting Potential (ODP) of zero (0).
However, any gas under pressure is potentially
hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with
liquid. Filling the cylinder to approximately 80% will
allow for normal expansion.
Use only R404A refrigerant that conforms to
the AHRI standard 700 specification. The use of any
other refrigerant may expose users and operators to
unexpected safety hazards.
Refrigerant liquid sprayed onto the skin may
cause serious damage to tissue. Keep eyes and skin
protected. If refrigerant burns should occur, flush
immediately with cold water. If burns are severe, apply
ice packs and contact a physician immediately.
Taylor
reminds
technicians
to
be
cautious
of
government
laws
regarding
refrigerant
recovery,
recycling, and reclaiming systems. If you have any
questions regarding these laws, please contact the
factory Service Department.
WARNING:
R404A
refrigerant
used
in
conjunction with polyolester oils is extremely moisture
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.
To the Operator
131122
Section 2
To the Operator
The Model 161 soft serve freezer has been carefully
engineered and manufactured to give you dependable
operation.
This unit, when properly operated and cared for, will
produce
a
consistent
quality
product.
Like
all
mechanical products, it will require cleaning and
maintenance.
A
minimum
amount
of
care
and
attention is necessary if the operating procedures
outlined in this manual are followed closely.
This Operator’s Manual should be read
before operating or performing any maintenance on
your equipment.
The Model 161 will NOT eventually compensate and
correct for any errors during the set- up or filling
operations. Thus, the initial assembly and priming
procedures are of extreme importance. It is strongly
recommended that personnel responsible for the
equipment’s
operation,
both
assembly
and
disassembly, go through these procedures together in
order to be properly trained and to make sure that no
misunderstandings exist.
In the event you should require technical assistance,
please contact your local authorized Taylor Distributor.
Note: Your Taylor warranty is valid only if the parts are
authorized Taylor parts, purchased from the local
authorized Taylor Distributor, and only if all required
service work is provided by an authorized Taylor
service technician. Taylor reserves the right to deny
warranty claims on units or parts if non- Taylor
approved parts or incorrect refrigerant were installed
in the unit, system modifications were performed
beyond factory recommendations, or it is determined
that the failure was caused by abuse, misuse, neglect,
or failure to follow all operating instructions. For full
details of your Taylor Warranty, please see the Limited
Warranty section in this manual.
If the crossed out wheeled bin symbol is
affixed to this product, it signifies that this product is
compliant with the EU Directive as well as other similar
legislation in effect after August 13, 2005. Therefore,
it must be collected separately after its use is
completed, and cannot be disposed as unsorted
municipal waste. The user is responsible for returning
the product to the appropriate collection facility, as
specified by your local code.
For additional information regarding applicable local
laws, please contact the municipal facility and/or local
distributor.
Compressor Warranty Disclaimer
The refrigeration compressor(s) on this unit are
warranted for the term stated in the Limited Warranty
section in this manual. However, due to the Montreal
Protocol and the U.S. Clean Air Act Amendments of
1990, many new refrigerants are being tested and
developed, thus seeking their way into the service
industry. Some of these new refrigerants are being
advertised as drop- in replacements for numerous
applications. It should be noted that in the event of
ordinary service to this unit’s refrigeration system,
only the refrigerant specified on the affixed data
label should be used. The unauthorized use of
alternate refrigerants will void your Taylor compressor
warranty. It is the unit owner’s responsibility to make
this fact known to any technician he employs.
It should also be noted that Taylor does not warrant the
refrigerant used in its equipment. For example, if the
refrigerant is lost during the course of ordinary service
to this machine, Taylor has no obligation to either
supply or provide its replacement either at billable or
unbillable terms. Taylor does have the obligation to
recommend a suitable replacement if the original
refrigerant is banned, obsoleted, or no longer available
during the five year warranty of the compressor.
The Taylor Company will continue to monitor the
industry and test new alternates as they are being
developed. Should a new alternate prove, through our
testing, that it would be accepted as a drop- in
replacement,
then
the
above
disclaimer
would
become null and void. To find out the current status of
an
alternate
refrigerant
as
it
relates
to
your
compressor warranty, call the local Taylor Distributor
or the Taylor Factory. Be prepared to provide the
Model/Serial Number of the unit in question.
We, at Taylor Company, are concerned about the
safety of the operator when he or she comes in contact
with the freezer and its parts. Taylor has gone to
extreme efforts to design and manufacture built- in
safety features to protect both you and the service
technician. As an example, warning labels have been
attached to the freezer to further point out safety
precautions to the operator.
IMPORTANT - Failure to adhere to the
following safety precautions may result in severe
personal injury. Failure to comply with these
warnings may damage the machine and its
components. Component damage will result in
part replacement expense and service repair
expense.
To Operate Safely:
DO NOT operate the freezer without reading
the Operator Manual. Failure to follow this instruction
may result in equipment damage, poor freezer
performance, health hazards, or personal injury.
This appliance is to be used only by trained
personnel. It is not intended for use by children or
people with reduced physical, sensory, or mental
capabilities, or lack of experience and knowledge,
unless given supervision or instruction concerning the
use of the appliance by a person responsible for their
safety. Children should be supervised to ensure that
they do not play with the appliance.
This equipment is provided with a grounding lug
that is to be properly attached to the rear of the frame
by the authorized installer. The installation location is
marked by the equipotential bonding symbol (5021 of
IEC 60417- 1) on the removable panel and the frame.
DO NOT use a water jet to clean or rinse the
freezer. Failure to follow these instructions may result
in serious electrical shock.
S
DO NOT operate the freezer unless it is
properly grounded.
S
DO NOT operate freezer with larger fuses
than specified on the data label.
S
All
repairs
must
be
performed
by
an
authorized Taylor service technician.
S
The main power supplies to machine must be
disconnected prior to performing repairs.
S
For
Cord
Connected Units:
Only Taylor
authorized service technicians or licensed
electricians may install a plug or replacement
cord on the unit.
S
Stationary appliances which are not equipped
with a power cord and a plug or another device
to disconnect the appliance from the power
source must have an all-pole disconnecting
device with a contact gap of at least 3 mm
installed in the external installation.
S
Appliances that are permanently connected to
fixed wiring and for which leakage currents
may
exceed
10
mA,
particularly
when
disconnected or not used for long periods, or
during initial installation, shall have protective
devices such as a GFI, to protect against the
leakage of current, installed by the authorized
personnel to the local codes.
S
Supply cords used with this unit shall be
oil-resistant,
sheathed
flexible
cable
not
lighter than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(Code designation 60245 IEC 57) installed
with the proper cord anchorage to relieve
conductors from strain, including twisting, at
the terminals and protect the insulation of the
conductors from abrasion.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent, or similarly qualified person, in order to
avoid a hazard.
Failure to follow these instructions may result in
electrocution. Contact your local authorized Taylor
Distributor for service.
DO NOT allow untrained personnel to operate
this machine.
S
DO NOT put objects or fingers in door spout.
S
DO NOT operate the freezer unless all service
panels and access doors are restrained with
screws.
S
DO NOT remove the freezer door or beater
assembly unless the control switches are in
the “OFF” position.
Failure to follow these instructions may result in severe
personal injury from hazardous moving parts.
This unit has many sharp edges that can
cause severe injuries.
S
DO NOT put objects or fingers in fill or
discharge openings. Failure to follow this
instruction
may
result
in
contaminated
product or personal injury from blade contact.
S
USE EXTREME CAUTION when removing
the beater assembly. The scraper blades are
very sharp and may cause injury.
Access to the service area of the unit is
restricted to persons having knowledge and practical
experience with the appliance, in particular as far as
safety and hygiene are concerned.
This freezer must be placed on a level
surface. Failure to comply may result in personal injury
or equipment damage.
Cleaning
and
sanitizing
schedules
are
governed by your Federal, State, or local regulatory
agencies and must be followed accordingly. Please
refer to the cleaning section of this manual for the
proper procedure to clean this unit.
This machine is designed to maintain product
temperature under 41_F (5_C). Any product being
added to this machine must be below 41_F (5_C).
Failure to follow this instruction may result in health
hazards and poor freezer performance.
DO NOT obstruct air intake and discharge openings:
A minimum of 6” (152 mm) on both sides, and 0” in the
rear is required. Install the skirt provided on the right
side of the unit. Failure to follow this instruction may
cause poor freezer performance and damage to the
machine.
This freezer is designed to operate indoors, under
normal
ambient
temperatures
of
70_- 75_F
(21_- 24_C). The freezer has successfully performed
in high ambient temperatures of 104_F (40_C) at
reduced capacity.
DO NOT run the machine without product. Failure to
follow this instruction can result in damage to the
machine.
NOISE LEVEL: Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of 1.0
meter from the surface of the machine and at a height
of 1.6 meters from the floor.
Operator Parts Identification
Section 4
Operator Parts Identification
Model 161
Figure 1
ITEM
DESCRIPTION
PART NO.
1
PAN-DRIP *161*
055206
2
PANEL -SIDE LEFT
058491
3
GASKET-HOPPER COVER
037042
4
COVER A.-HOPPER
X37963-SER
4a
KNOB-MIX COVER
025429
5
TUBE-FEED
030797
6
PANEL-REAR
058492
ITEM
DESCRIPTION
PART NO.
7
PANEL A.-SIDE-RIGHT
X58490
8
GASKET-BASE PAN
055815
9
TRAY-DRIP 16-7/8L X 4-5/16
020157-SP
10
SHIELD-SPLASH
022765
11
PANEL-LOWER FRONT
058493
12
PANEL A.-FRONT *161*
X58488
Operator Parts Identification
140409
Beater Door Assembly
Figure 2
ITEM
DESCRIPTION
PART NO.
1
VALVE-DRAW
024763-SP
2
O-RING-7/8 OD X .103W
014402
3
SEAL-DRAW VALVE
*SMALL H-RING*
030930
4
DOOR A.-3SPT 1.5QT VALOX
X56906SER1
5
PIN A.-PIVOT *168-SHORT*
X38539
6
O-RING-5/16 OD X .070W
016272
7
HANDLE-DRAW VALVE
030564
8
NUT-STUD
056802
ITEM
DESCRIPTION
PART NO.
9
CAP-DESIGN 1.010"ID-6 PT.
014218
10
PIN A.-PIVOT *168-LONG*
X38538
11
BEARING-GUIDE
014496
12
VALVE-DRAW-CENTER
031164
13
O-RING-2-3/4 OD X .139W
019998
14
BEARING-FRONT
023262
15
BEATER A.-*150
X24689
16
SEAL-U-CUP
080534
Operator Parts Identification
110727
Accessories
Figure 3
ITEM
DESCRIPTION
PART NO.
1
PAIL-6·QT.
023348
2
BRUSH-REAR BRG 1” D X 2” LG
013071
3
BRUSH-DOUBLE·ENDED
013072
4
BRUSH-DRAW·VALVE·1” OD X
2” X 17”
013073
ITEM
DESCRIPTION
PART NO.
5
BRUSH-MIX·PUMP·BODY-3”X7”
WHITE
023316
6
LUBRICANT-TAYLOR·4·OZ.
047518
7
KIT·A.-TUNE·UP
X31167
*
SANITIZER KAY-5 25 PKTS
SEE NOTE
*Not Shown - Note: A sample container of sanitizer is
sent with the unit. For reorders, order Kay-5 part no.
041082 (200 packs) or Stera Sheen part no. 055492
(100 2 oz. packs).
Important: To the Operator
Section 5
Important: To the Operator
Figure 4
ITEM
DESCRIPTION
1
POWER SWITCH
2
MIX REFRIGERATION KEY
3
STANDBY KEY
4
WASH KEY
5
AUTO KEY
6
INDICATOR LIGHT “MIX LOW”
7
RESET BUTTON
Symbol Definitions
To better communicate in the International arena, the
words on many of our operator switchesand keyshave
symbols to indicate their functions. Your Taylor
equipment
is
designed
with
these
International
symbols.
The following chart identifies the symbol definitions
used on the operator switches.
= OFF
= ON
= MIX
= STANDBY
= WASH
= AUTO
= MIX LOW
Important: To the Operator
130703
Power Switch
When placed in the ON position, the power switch
allows Softecht control panel operation.
MIX REF Key
When the MIX REF key is pressed, the light comes on
indicating the mix hopper refrigeration system is
operating. MIX REF is controlled by the left side of the
freezer as viewed from the operator end. The MIX REF
function cannot be cancelled unless the AUTO or
STANDBY modes are cancelled first.
STANDBY Key
This unit is equipped with a STANDBY feature. If
product is not dispensed for long periods of time (i.e.;
early morning hours), the STANDBY feature can be
activated to maintain the hopper and freezing cylinder
product at safe temperatures and prevent product
breakdown. In the STANDBY mode, the WASH and
AUTO functions are automatically cancelled.
To use the Standby feature, perform the following
steps:
Note: Be sure your hands are clean and sanitized
before performing the following steps.
Step 1
Invert the mix feed tube so the end with the mix
delivery hole is positioned at the top. Install the end
without the mix delivery hole into the mix inlet hole in
the bottom of the hopper. This will prevent mix from
entering the freezing cylinder.
Feed Tube Position During Standby Operation:
Figure 5
Step 2
Make sure there is at least 3” (76 mm) of mix in the
hopper and that the level of mix is not above the mix
delivery hole on the side of the feed tube.
Note: The level of mix must be below the mix
delivery hole on the side of the feed tube. Failure
to follow this instruction may result in lower product
quality when normal operation is resumed.
Step 3
Press the STANDBY key. The light will illuminate,
indicating that the unit is operating as a refrigerator for
product in the hopper and freezing cylinder.
Step 4
To remove the unit from the STANDBY mode, press
the AUTO key. The STANDBY light will extinguish,
indicating the unit has resumed the normal operating
mode.
Step 5
When the unit cycles off, place the feed tube in its
original position (mix delivery hole end down).
Feed Tube Position During Normal Operation:
Figure 6
IMPORTANT: The STANDBY mode must
not be used in lieu of daily disassembly, cleaning,
and sanitizing.
Important: To the Operator
130703
WASH Key
When the WASH key is pressed, the light comes on.
This indicates beater motor operation. The STANDBY
or AUTO mode must be cancelled first to activate the
WASH mode.
AUTO Key
When the AUTO key is pressed, the light comes on.
This indicates that the main refrigeration system has
been activated. In the AUTO mode, the WASH or
STANDBY functions are automatically cancelled. The
MIX REF function is automatically locked in to
maintain the temperature of the mix in the mix hopper.
Note: An indicating light and an audible tone will
sound whenever a mode of operation has been
pressed. To cancel any function, press the key again.
The light and mode of operation will shut off.
Indicator Light - MIX LOW
Located on the front of the machine is a mix level
indicating light. When the light is flashing, it indicates
that the mix hopper has a low supply of mix and should
be refilled as soon as possible. Always maintain at
least 3” (76 mm) of mix in the hopper. If you neglect to
add mix, a freeze- up may occur. This will cause
eventual damage to the beater, blades, drive shaft,
and freezer door.
Reset Button
The reset button is located on the front of the unit. The
reset protects the beater motor from an overload
condition. If an overload occurs, the reset mechanism
will trip. To properly reset the freezer, press the AUTO
key to cancel the cycle. Turn the power switch to the
OFF position. Wait two or three minutes and then
press the reset button firmly.
Warning: Do not use metal objects to
press the reset button. Failure to comply may
result in severe personal injury or death.
Turn the power switch to the ON position. Press the
WASH key and observe the freezer’s performance. If
the beater motor is turning properly, press the WASH
key to cancel the cycle. Press the AUTO key on both
sides of the unit to resume normal operation. If the
freezer shuts down again, contact an authorized
service technician.
Feed Tube
The feed tube maintains overrun and allows enough
mix to enter the freezing cylinder after a draw. One end
of the tube has a mix delivery hole on the side and the
other end does not.
Figure 7
The feed tube serves two purposes.
1.
Normal Operation: After priming the machine,
the end of the feed tube with the mix delivery hole
is placed in the mix inlet hole. Every time the draw
handle is raised, new mix and air from the hopper
will flow down into the freezing cylinder. This will
keep the freezing cylinder properly loaded and
will maintain overrun.
Feed Tube Position During Normal Operation:
Figure 8
Important: To the Operator
130703
2.
Standby Operation: During long “No Sale”
periods, the feed tube is inverted. The end of the
feed tube without the mix delivery hole is placed
in the mix inlet hole to prevent mix from entering
the freezing cylinder.
Feed Tube Position During Standby Operation:
Figure 9
Note: Make sure the level of mix is below the mix
delivery hole in the side of the feed tube. Failure to
follow this instruction may result in lower product
quality when normal operation is resumed.
The Model 161 is a soft serve counter model with a
three spout door. Two individual flavors are available
from the end spouts, and an equal combination of both
is dispensed through the center spout to create a twist
effect. It has a 1.5 quart (1.4 liter) capacity freezing
cylinder. The mix flows by gravity from the hopper to
the freezing cylinder through a feed tube.
Duplicate the procedures where they apply for the
second freezing cylinder.
We begin our instructions at the point where we enter
the
store
in
the
morning
and
find
the
parts
disassembled and laid out to air dry from the previous
night’s cleaning.
These opening procedures will show you how to
assemble these parts into the machine, sanitize them,
and prime the machine with fresh mix in preparation to
serve your first portion.
Figure 10
If you are disassembling the machine for the first time
or need information to get to the starting point in our
instructions, turn to page 20, “Disassembly”, and start
there.
Assembly
Note: When lubricating parts, use an approved food
grade lubricant (example: Taylor Lube).
Step 1
Lubricate the groove on the beater drive shaft. Withthe
opening of the cup seal facing away from the hex end,
slide the seal into the groove. Apply an even coat of
lubricant
to
the
seal
and
the
shaft.
Do
not
lubricate the hex end of the beater drive shaft.
Figure 11
Step 2
Insert the beater assembly through the rear shell
bearing at the back of the freezing cylinder and engage
the hex end firmly into the female socket. When
properly seated, the beater will not protrude beyond
the front of the freezing cylinder.
Figure 12
Repeat Steps 1 through 2 for the other side of the
machine.
Place the large o- rings into the grooves on the back of
the machine door and lubricate.
Figure 13
Step 4
Slide the front bearings over the baffle rods so the
flanged edge is against the door. Place the white
plastic guide bearings on the end of the baffle rods.
DO NOT lubricate the front bearings or the guide
bearings.
Figure 14
Step 5
Slide the slotted portion of the handscrews into the
slots in the freezer door.
Step 6
With both hands, hold the sides of the freezer door and
insert the baffle rods into the center of the beater
assemblies.
The
white
guide bearings
must fit
securely in the holes of the drive shafts.
Step 7
Finger- tighten the handscrews, making sure they are
tightened equally and that the door is snug. Do not
over- tighten the handscrews.
Figure 15
IMPORTANT! Handscrew and door damage can
result if the handscrews are over- tightened or if
one handscrew is tightened more than the other.
Step 8
Install the valve seal into the grooves on the center
draw valve and lubricate. This special seal will prevent
the mix in one freezing cylinder from traveling into the
second cylinder.
Figure 16
Slide the two o- rings into the grooves on the remaining
draw valves and lubricate.
Figure 17
Step 10
Lubricate the inside of the freezer door spouts from the
bottom. Insert the draw valves into the freezer door
from the bottom until the slot in the draw valves comes
into view.
Figure 18
Step 11
Slide the o- ring onto each pivot pin and lubricate.
Figure 19
Step 12
Slide the tip of the draw handle into the slot of the draw
valve, starting from the right. Slide the short pivot pin
through the far right draw handle. Slide the long pivot
pin through the far left and middle draw handles.
Figure 20
Snap the design caps over the bottom of the freezer
door spouts.
Figure 21
Step 14
Lay the feed tubes in the bottom of the mix hoppers.
Step 15
Install the front drip tray and splash shield under the
freezer door.
Figure 22
Step 16
Install the drip pans.
Figure 23
Sanitizing
Step 1
Prepare an approved 100 PPM sanitizing solution
(examples: 2- 1/2 gal. [9.5 liters] of Kay- 5R
or 2
gal. [7.6 liters] of Stera- SheenR). USE WARM WA-
TER AND FOLLOW THE MANUFACTURER’S
SPECIFICATIONS.
Step 2
Pour one gallon (3.8 liters) of sanitizing solution into
the hopper and allow it to flow into the freezingcylinder.
Figure 24
While the solution is flowing into the freezing cylinder,
brush clean the mix hopper, the mix inlet hole, and the
feed tube.
Figure 25
Figure 26
Step 4
Place the power switch in the ON position.
Figure 27
Step 5
Press the WASH key. This will cause the sanitizing
solution in the freezing cylinder to be agitated. Allow it
to agitate for five minutes.
Figure 28
Step 6
Place an empty pail beneath the door spouts.
Momentarily open the center draw valve to sanitize the
center door spout. Open the remaining draw valves to
remove all of the sanitizing solution. When the
sanitizer stops flowing from the door spouts, close the
draw valves. Press the WASH key to cancel the WASH
mode.
Step 7
With sanitized hands, stand the feed tube in the corner
of the mix hopper.
Figure 29
Repeat Steps 1 through 7 for the other side of the
machine.
Prime the machine as close as possible to the time of
first product draw.
Step 1
With a pail beneath the door spouts, open the draw
valves. Fill the mix hopper with FRESH mix and allow
it to flow into the freezing cylinder. This will force out
any remaining sanitizing solution. When full strength
mix is flowing from the door spouts, close the draw
valves.
Note: Use only fresh mix when priming the
machine.
Step 2
When the mix has stopped bubbling down into the
freezing cylinder, install the feed tube in the mix inlet
hole.
Figure 30
Step 3
Press the AUTO key. When the unit cycles off, the
product will be ready to serve.
Figure 31
Repeat Steps 1 through 3 for the other side of the
machine.
Step 4
Place the mix hopper gasket and the mix hopper cover
in position.
Closing Procedure
To disassemble the Model 161, the following items will
be needed:
S
Two cleaning pails
S
Sanitized stainless steel rerun can with lid
S
Necessary brushes (provided with machine)
S
Cleaner
S
Single service towels
Draining Product From the
Freezing Cylinder
Step 1
Press the AUTO key to cancel operation. Press the
MIX REF key to cancel hopper refrigeration. These
operations should be cancelled as far ahead of
cleaning time as possible. This will allow frozen
product to soften for easier cleaning.
Step 2
Remove the mix hopper cover, the mix hopper gasket,
and the feed tube. Take them to the sink for cleaning.
Step 3
If local health codes permit the use of rerun, place
a sanitized, NSF approved stainless steel rerun
container beneath the door spouts. Press the WASH
key and open the draw valves. When all the product
stops flowing from the door spouts, close the draw
valves and press the WASH key to cancel the WASH
mode. Place the sanitized lid on the rerun container
and place it in the walk- in cooler.
Note: If local health codes DO NOT permit the use
of rerun, the product must be discarded. Follow the
instructions in the previous step, except drain the
product into a pail and properly discard the mix.
ALWAYS FOLLOW LOCAL HEALTH CODES.
Repeat Steps 1 through 3 for the other side of the
machine.
Pour one gallon (3.8 liters) of cool, clean water into the
mix hopper. With the brushes provided, scrub the mix
hopper, and the mix inlet hole.
Step 2
With a pail beneath the door spouts, press the WASH
key and open the draw valves.
Step 3
Drain all the rinse water from the freezing cylinder.
When the rinse water stops flowing from the door
spout, close the draw valves and press the WASH key
to cancel.
Repeat this procedure until the rinse water being
drawn from the freezing cylinder is clear.
Repeat Steps 1 through 3 for the other side of the
machine.
Cleaning
Step 1
Prepare an approved 100 PPM cleaning solution
(examples: 2- 1/2 gal. [9.5 liters] of Kay- 5R
or 2
gal. [7.6 liters] of Stera- SheenR). USE WARM WA-
TER AND FOLLOW THE MANUFACTURER’S
SPECIFICATIONS.
Step 2
Pour one gallon (3.8 liters) of cleaning solution into
the mix hopper and allow it to flow into the freezing
cylinder.
Step 3
While the solution is flowing into the freezing cylinder,
brush clean the mix hopper and the mix inlet hole.
Step 4
Press the WASH key. This will cause the cleaning
solution in the freezing cylinder to agitate.
Step 5
Place an empty pail beneath the door spouts and raise
the draw valve. Draw off all the cleaning solution.
When the solution stops flowing from the door spouts,
close the draw valves. Press the WASH key to cancel.
Repeat Steps 1 through 5 for the other side of the
machine.
Disassembly
MAKE SURE THE POWER SWITCH IS IN
THE
“OFF”
POSITION.
Failure
to
follow
this
instruction may result in severe personal injury to
fingers or hands from hazardous moving parts.
Step 1
Remove the handscrews and the freezer door.
Remove the beater assemblies from the freezing
cylinders and take these parts to the sink for cleaning.
Step 2
Remove the front drip tray, the splash shield, and the
drip pans from the machine. Take them to the sink for
cleaning.
Brush Cleaning
Step 1
Prepare a sink with an approved cleaning solution
(examples: Kay- 5R or Stera- SheenR). USE WARM
WATER AND FOLLOW THE MANUFACTURER’S
SPECIFICATIONS.
IMPORTANT:
Follow
label
directions,
as
too
STRONG of a solution can cause parts damage, while
too MILD of a solution will not provide adequate
cleaning.) Make sure all brushes provided with the
machine are available for brush cleaning.
Step 2
Remove the cup seals from the drive shafts of the
beater assemblies.
From the freezer door, remove design caps, pivot pins,
draw handles, and draw valves. Remove all o- rings.
Note: To remove o- rings, use a single service towel
to grasp the o- ring. Apply pressure in an upward
direction until the o- ring pops out of its groove. With
the other hand, push the top of the o- ring forward, and
it will roll out of the groove and can be easily removed.
If there is more than one o- ring to be removed, always
remove the rear o- ring first. This will allow the o- ring
to slide over the forward rings without falling into the
open grooves.
Step 4
Remove the large o- rings, front bearings, and guide
bearings from the back of the freezer door.
Step 5
Return to the machine with a small amount of cleaning
solution. With the black bristle brush, brush clean the
rear shell bearings at the back of the freezing
cylinders.
Note: If the drip pan was filled with an excessive
amount of mix, this is an indication that the drive shaft
o- ring of the beater assembly should be replaced or
properly lubricated.
Step 6
Thoroughly brush clean all disassembled parts in the
cleaning solution. Make sure all lubricant and mix film
is removed. Take particular care to brush clean the
draw valve cores in the freezer door. Place all the
cleaned parts on a clean, dry surface to air dry
overnight.
Step 7
Wipe clean all exterior surfaces of the machine.
Important: Operator Checklist
Section 7
Important: Operator Checklist
During Cleaning and Sanitizing
ALWAYS FOLLOW LOCAL HEALTH CODES.
Cleaning and sanitizing schedules are governed
by federal, state, or local regulatory agencies, and
must be followed accordingly. If the unit has a
“Standby mode”, it must not be used in lieu of
proper cleaning and sanitizing procedures and
frequencies
set
forth
by
the
ruling
health
authority. The following check points should be
stressed
during
the cleaning
and sanitizing
operations.
CLEANING AND SANITIZING MUST BE
PERFORMED DAILY.
Troubleshooting Bacterial Count
j 1. Thoroughly clean and sanitize the machine
regularly, including complete disassembly and
brush cleaning.
j 2. Use all brushes supplied for thorough cleaning.
The brushes are specially designed to reach all
mix passageways.
j 3. Use the smaller, white bristle brush to clean the
mix inlet hole which extends from the mix
hopper down to the rear of the freezing cylinder.
j 4. Use the black bristle brush to thoroughly clean
the rear shell bearing located at the rear of the
freezing cylinder. Be sure to have a generous
amount of cleaning solution on the brush.
j 5. IF LOCAL HEALTH CODES PERMIT THE
USE OF RERUN, make sure the mix rerun is
stored in a sanitized, covered stainless steel
container and is used the following day. DO
NOT prime the machine with rerun. When using
rerun, skim off the foam and discard. Mix the
rerun with fresh mix in a ratio of 50/50 during the
day’s operation.
j 6. On a designated day of the week, run the mix as
low as feasible and discard after closing. This
will break the rerun cycle and reduce the
possibility of high bacteria and coliform counts.
j 7. Properly prepare the cleaning and sanitizing
solutions. Read and follow label directions
carefully. Too strong of a solution may damage
the parts and too weak of a solution will not do
an adequate job of cleaning or sanitizing.
j 8. The temperature of the mix in the mix hopper
and walk- in cooler should be below 40_F.
(4.4_C.).
Regular Maintenance Checks
j 1. Check the rear shell bearing for signs of wear
(excessive mix leakage in rear drip pan) and be
certain it is properly cleaned.
j 2. Using a screwdriver and cloth towel, keep the
rear shell bearing and the female hex drive
socket clean and free of lubricant and mix
deposits.
j 3. Dispose of o- rings or seals if they are worn,
torn, or fit too loosely, and replace with new
ones.
j 4. Follow all lubricating procedures as outlined in
“Assembly”.
Important: Operator Checklist
j 5. If your machine is air cooled, check the
condenser for an accumulation of dirt and lint.
A dirty condenser will reduce the efficiency and
capacity of the machine. Condensers should be
cleaned monthly with a soft brush. Never use
screwdrivers or other metal probes to clean
between the fins.
Note: For machines equipped with an air filter,
it will be necessary to vacuum clean the filters
on a monthly schedule.
CAUTION: Always disconnect elec-
trical power prior to cleaning the condens-
er. Failure to follow this instruction may result in
electrocution.
j 6. If your machine is equipped with an auxiliary
refrigeration
system,
check
the
auxiliary
condenser for accumulation of dirt and lint. A
dirty condenser will reduce the refrigeration
capacity of the mix hopper. Condensers must
be cleaned monthly with a soft brush. Never
use screwdrivers or other metal probes to clean
between the fins. Failure to comply may result
in electrocution.
j 7. If your machine is water cooled, check the water
lines for kinks or leaks. Kinks can occur when
the machine is moved back and forth for clean-
ing or maintenance purposes. Deteriorated or
cracked water lines should be replaced only by
an authorized Taylor mechanic.
Winter Storage
If the place of business is to be closed during the winter
months, it is important to protect the freezer by
following
certain
precautions,
particularly
if
the
building is subject to freezing conditions.
Disconnect the freezer from the main power source to
prevent possible electrical damage.
On water cooled freezers, disconnect the water
supply. Relieve pressure on the spring in the water
valve. Use air pressure on the outlet side to blow out
any water remaining in the condenser. This is
extremely important. Failure to follow this procedure
may
cause
severe
and
costly
damage
to
the
refrigeration system.
Your local Taylor distributor can perform this servicefor
you.
Wrap detachable parts of the freezer such as the
beater assembly and freezer door, and place them in
a protected dry place. Rubber trim parts and gaskets
can
be
protected
by
wrapping
them
with
moisture- proof paper. All parts should be thoroughly
cleaned of dried mix or lubrication accumulations
which attract mice and other vermin.
No product being
dispensed.
a. The power switch is in the
OFF position.
a. Place the power switch in
the AUTO position.
18
b. The mix level is
inadequate in the mix
hopper.
b. Fill the mix hopper with
mix.
19
c. The beater motor
overloaded.
c. Reset the freezer.
12
d. The unit is unplugged at
the wall receptacle.
d. Plug in the power cord.
3
e. The circuit breaker is
tripped or the fuse is
blown.
e. Place the circuit breaker in
the “ON” position or
replace the fuse.
- - -
f. The freezer door is
incorrectly assembled.
f. See “Operating
Procedures” for proper
installation.
15
g. Product is being drawn off
in excess of the freezer’s
capacity.
g. Stop drawing product and
allow the unit to recover.
- - -
2.
The machine will not
operate in the AUTO
mode.
a. The unit is unplugged.
a. Plug in the power cord.
3
b. The refrigeration system is
not activated.
b. Momentarily raise the
draw switch to activate the
refrigeration system.
- - -
c. The circuit breaker is
tripped, or the fuse is
blown.
c. Place the circuit breaker in
the ON position or replace
the fuse.
- - -
d. The beater motor
overloaded, causing a loss
of power to the power
switch.
d. Reset the freezer.
12
3.
The product is too stiff.
a. The control is set too cold.
a. Contact service
technician.
- - -
The product is too soft.
a. The control is set too
warm.
a. Contact service
technician.
- - -
b. The air tube is not
installed.
b. Install the air tube in the
mix inlet hole at the
bottom of the mix hopper.
19
c. Out- drawing the freezer’s
capacity.
c. Two 4 oz. (113.4 gram)
servings in one minute.
- - -
5.
The freezing cylinder walls
are scored.
a. Operating freezer without
the front bearing on the
freezer door.
a. Install the front bearing on
the freezer door.
15
b. The gear unit or the direct
drive is out of alignment.
b. Contact service
technician.
- - -
6.
Excessive leakage in rear
drip pan.
a. A worn or defective o- ring
is on the beater drive
shaft.
a. Replace o- rings every 3
months.
27
b. The rear shell bearing is
worn.
b. Contact service
technician.
- - -
c. Incorrect lubricant was
used.
c. Use food grade lubricant
(example: Taylor Lube).
14
d. Inadequate lubrication of
beater drive shaft.
d. Lubricate the beater drive
shaft properly.
14
7.
The draw valve is leaking.
a. Incorrect lubricant was
used.
a. Use food grade lubricant
(example: Taylor Lube).
15
b. Worn or defective o- rings
are on the draw valve.
b. Replace o- rings every 3
months.
27
c. Inadequate lubrication of
draw valve.
c. Lubricate the draw valve
properly.
15
8.
Product is not feeding into
the freezing cylinder.
a. The mix level is
inadequate in the mix
hopper.
a. Fill the mix hopper with
mix.
19
b. The mix inlet hole is
frozen.
b. Contact service
technician.
- - -
The unit goes out on
overload excessively.
a. There are too many
appliances plugged into
the circuit.
a. A separate 20A circuit is
needed for the freezer to
operate properly.
- - -
b. An extension cord has
been placed between the
power cord and the wall
receptacle.
b. If the extension cord is
used, it must match the
power cord in size of
circuit ampacity.
- - -
10. Mix from one freezing
cylinder bleeds over to the
second cylinder.
a. The center draw valve
seal is worn, or is
improperly lubricated.
a. Lubricate properly and
replace seal every 3
months.
15 / 27
Parts Replacement Schedule
120501
Section 9
Parts Replacement Schedule
PART DESCRIPTION
EVERY 3 MONTHS
EVERY 6 MONTHS
ANNUALLY
QTY.
Beater Drive Shaft Cup Seal
X
2
Freezer Door O- Ring
X
2
Freezer Door Front Bearing
X
2
Freezer Door Guide Bearing
X
2
Draw Valve O- Ring
X
4
Center Draw Valve Seal
X
1
Pivot Pin O- Ring
X
2
Black Bristle Brush, 1” x 2”
Inspect & Replace
if Necessary
Minimum
1
Double Ended Brush
Inspect & Replace
if Necessary
Minimum
1
White Bristle Brush, 1” x 2”
Inspect & Replace
if Necessary
Minimum
1
White Bristle Brush, 3” x 7”
Inspect & Replace
if Necessary
Minimum
1
Limited Warranty on Equipment
131122
Section 10
Limited Warranty on Equipment
TAYLOR COMPANY LIMITED WARRANTY ON FREEZERS
Taylor Company, a division of Carrier Commercial Refrigeration, Inc. (“Taylor”) is pleased to provide this limited
warranty on new Taylor-branded freezer equipment available from Taylor to the market generally (the “Product”)
to the original purchaser only.
LIMITED WARRANTY
Taylor warrants the Product against failure due to defect in materials or workmanship under normal use and
service as follows. All warranty periods begin on the date of original Product installation. If a part fails due to
defect during the applicable warranty period, Taylor, through an authorized Taylor distributor or service agency,
will provide a new or re- manufactured part, at Taylor’s option, to replace the failed defective part at no charge for
the part. Except as otherwise stated herein, these are Taylor’s exclusive obligations under this limited warranty for
a Product failure. This limited warranty is subject to all provisions, conditions, limitations and exclusions listed
below and on the reverse (if any) of this document.
Product
Part
Limited Warranty Period
Soft Serve
Frozen Yogurt
Shakes
Smoothies
Frozen Beverage
Batch Desserts
Insulated shell assembly
Five (5) years
Refrigeration compressor
(except service valve)
Five (5) years
Beater motors
Two (2) years
Beater drive gear
Two (2) years
Printed circuit boards and
Softech controls beginning
with serial number H8024200
Two (2) years
Parts not otherwise listed in
this table or excluded below
One (1) year
LIMITED WARRANTY CONDITIONS
1.
If the date of original installation of the Product cannot be verified, then the limited warranty period begins
ninety (90) days from the date of Product manufacture (as indicated by the Product serial number). Proof of
purchase may be required at time of service.
2.
This limited warranty is valid only if the Product is installed and all required service work on the Product is
performed by an authorized Taylor distributor or service agency, and only if genuine, new Taylor parts are
used.
3.
Installation, use, care, and maintenance must be normal and in accordance with all instructions contained in
the Taylor Operator’s Manual.
4.
Defective parts must be returned to the authorized Taylor distributor or service agency for credit.
5.
The use of any refrigerant other than that specified on the Product’s data label will void this limited warranty.
LIMITED WARRANTY EXCEPTIONS
This limited warranty does not cover:
1.
Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of
defective parts, replacement parts, or new Products.
2.
Normal maintenance, cleaning and lubrication as outlined in the Taylor Operator’s Manual, including cleaning
of condensers.
Limited Warranty on Equipment
3.
Replacement of wear items designated as Class “000” parts in the Taylor Operator’s Manual.
4.
External hoses, electrical power supplies, and machine grounding.
5.
Parts not supplied or designated by Taylor, or damages resulting from their use.
6.
Return trips or waiting time required because a service technician is prevented from beginning warranty
service work promptly upon arrival.
7.
Failure, damage or repairs due to faulty installation, misapplication, abuse, no or improper servicing,
unauthorized alteration or improper operation or use as indicated in the Taylor Operator’s Manual, including
but not limited to the failure to use proper assembly and cleaning techniques, tools, or approved cleaning
supplies.
8.
Failure, damage or repairs due to theft, vandalism, wind, rain, flood, high water, water, lightning, earthquake
or any other natural disaster, fire, corrosive environments, insect or rodent infestation, or other casualty,
accident or condition beyond the reasonable control of Taylor; operation above or below the electrical or
water supply specification of the Product; or components repaired or altered in any way so as, in the
judgment of the Manufacturer, to adversely affect performance, or normal wear or deterioration.
9.
Any Product purchased over the Internet.
10.
Failure to start due to voltage conditions, blown fuses, open circuit breakers, or damages due to the
inadequacy or interruption of electrical service.
11.
Electricity or fuel costs, or increases in electricity or fuel costs from any reason whatsoever.
12.
Damages resulting from the use of any refrigerant other than that specified on the Product’s data label will
void this limited warranty.
13.
Any cost to replace, refill or dispose of refrigerant, including the cost of refrigerant.
14.
ANY SPECIAL, INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY
NATURE WHATSOEVER. Some jurisdictions do not allow the exclusion of incidental or consequential
damages, so this limitation may not apply to you.
This limited warranty gives you specific legal rights, and you may also have other rights which vary from
jurisdiction to jurisdiction.
LIMITATION OF WARRANTY
THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS
AND/OR REMEDIES UNDER THE LAW, INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE ORIGINAL OWNER’S SOLE
REMEDY WITH RESPECT TO ANY PRODUCTS SHALL BE REPAIR OR REPLACEMENT OF DEFECTIVE
COMPONENTS UNDER THE TERMS OF THIS LIMITED WARRANTY. ALL RIGHTS TO CONSEQUENTIAL
OR INCIDENTAL DAMAGES (INCLUDING CLAIMS FOR LOST SALES, LOST PROFITS, PRODUCT LOSS,
PROPERTY DAMAGES OR SERVICE EXPENSES) ARE EXPRESSLY EXCLUDED. THE EXPRESS
WARRANTIES MADE IN THIS LIMITED WARRANTY MAY NOT BE ALTERED, ENLARGED, OR CHANGED
BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON, WHATSOEVER.
LEGAL REMEDIES
The owner must notify Taylor in writing, by certified or registered letter to the following address, of any defect or
complaint with the Product, stating the defect or complaint and a specific request for repair, replacement, or other
correction of the Product under warranty, mailed at least thirty (30) days before pursuing any legal rights or
remedies.
Taylor Company
a division of Carrier Commercial Refrigeration, Inc.
750 N. Blackhawk Blvd.
Rockton, IL
61072, U.S.A.
Limited Warranty on Parts
131122
Section 11
Limited Warranty on Parts
TAYLOR COMPANY LIMITED WARRANTY ON TAYLOR GENUINE PARTS
Taylor Company, a division of Carrier Commercial Refrigeration, Inc. (“Taylor”) is pleased to provide this limited
warranty on new Taylor genuine replacement components and parts available from Taylor to the market generally
(the “Parts”) to the original purchaser only.
LIMITED WARRANTY
Taylor warrants the Parts against failure due to defect in materials or workmanship under normal use and service
as follows. All warranty periods begin on the date of original installation of the Part in the Taylor unit. If a Part fails
due to defect during the applicable warranty period, Taylor, through an authorized Taylor distributor or service
agency, will provide a new or re- manufactured Part, at Taylor’s option, to replace the failed defective Part at no
charge for the Part. Except as otherwise stated herein, these are Taylor’s exclusive obligations under this limited
warranty for a Part failure. This limited warranty is subject to all provisions, conditions, limitations and exclusions
listed below and on the reverse (if any) of this document.
Part’s Warranty Class Code or Part
Limited Warranty Period
Class 103 Parts¹
Three (3) months
Class 212 Parts²
Twelve (12) months
Class 512 Parts
Twelve (12) months
Class 000 Parts
No warranty
Taylor Part #072454 (Motor- 24VDC *C832/C842*)
Four (4) years
LIMITED WARRANTY CONDITIONS
1.
If the date of original installation of the Part cannot be otherwise verified, proof of purchase may be required
at time of service.
2.
This limited warranty is valid only if the Part is installed and all required service work in connection with the
Part is performed by an authorized Taylor distributor or service agency.
3.
The limited warranty applies only to Parts remaining in use by their original owner at their original installation
location in the unit of original installation.
4.
Installation, use, care, and maintenance must be normal and in accordance with all instructions contained in
the Taylor Operator’s Manual.
5.
Defective Parts must be returned to the authorized Taylor distributor or service agency for credit.
6.
This warranty is not intended to shorten the length of any warranty coverage provided pursuant to a separate
Taylor Limited Warranty on freezer or grill equipment.
7.
The use of any refrigerant other than that specified for the unit in which the Part is installed will void this
limited warranty.
1, 2 Except that Taylor Part #032129SER2 (Compressor-Air-230V SERV) and Taylor Part #075506SER1
(Compressor-Air-115V 60HZ) shall have a limited warranty period of twelve (12) months when used in Taylor
freezer equipment and a limited warranty period of two (2) years when used in Taylor grill equipment.
Limited Warranty on Parts
LIMITED WARRANTY EXCEPTIONS
This limited warranty does not cover:
1.
Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of
defective Parts, replacement Parts, or new Parts.
2.
Normal maintenance, cleaning and lubrication as outlined in the Taylor Operator’s Manual, including cleaning
of condensers or carbon and grease buildup.
3.
Required service, whether cleaning or general repairs, to return the cooking surface assemblies, including
the upper platen and lower plate, to an operational condition to achieve proper cooking or allow proper
assembly of release sheets and clips as a result of grease build-up on the cooking surfaces, including but
not limited to the platen and plate, sides of the shroud or top of the shroud.
4.
Replacement of cooking surfaces, including the upper platen and lower plate, due to pitting or corrosion (or
in the case of the upper platen, due to loss of plating) as a result of damage due to the impact of spatulas or
other small wares used during the cooking process or as a result of the use of cleaners, cleaning materials
or cleaning processes not approved for use by Taylor.
5.
Replacement of wear items designated as Class “000” Parts in the Taylor Operator’s Manual, as well as any
release sheets and clips for the Product’s upper platen assembly.
6.
External hoses, electrical power supplies, and machine grounding.
7.
Parts not supplied or designated by Taylor, or damages resulting from their use.
8.
Return trips or waiting time required because a service technician is prevented from beginning warranty
service work promptly upon arrival.
9.
Failure, damage or repairs due to faulty installation, misapplication, abuse, no or improper servicing,
unauthorized alteration or improper operation or use as indicated in the Taylor Operator’s Manual, including
but not limited to the failure to use proper assembly and cleaning techniques, tools, or approved cleaning
supplies.
10.
Failure, damage or repairs due to theft, vandalism, wind, rain, flood, high water, water, lightning, earthquake
or any other natural disaster, fire, corrosive environments, insect or rodent infestation, or other casualty,
accident or condition beyond the reasonable control of Taylor; operation above or below the gas, electrical or
water supply specification of the unit in which a part is installed; or Parts or the units in which they are
installed repaired or altered in any way so as, in the judgment of Taylor, to adversely affect performance, or
normal wear or deterioration.
11.
Any Part purchased over the Internet.
12.
Failure to start due to voltage conditions, blown fuses, open circuit breakers, or damages due to the
inadequacy or interruption of electrical service.
13.
Electricity, gas or other fuel costs, or increases in electricity or fuel costs from any reason whatsoever.
14.
Damages resulting from the use of any refrigerant other than that specified for the unit in which the Part is
installed will void this limited warranty.
15.
Any cost to replace, refill or dispose of refrigerant, including the cost of refrigerant.
16.
ANY SPECIAL, INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY
NATURE WHATSOEVER. Some jurisdictions do not allow the exclusion of incidental or consequential
damages, so this limitation may not apply to you.
This limited warranty gives you specific legal rights, and you may also have other rights which vary from
jurisdiction to jurisdiction.
Limited Warranty on Parts
LIMITATION OF WARRANTY
THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS
AND/OR REMEDIES UNDER THE LAW, INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE ORIGINAL OWNER’S SOLE
REMEDY WITH RESPECT TO ANY PRODUCTS SHALL BE REPAIR OR REPLACEMENT OF DEFECTIVE
PARTS UNDER THE TERMS OF THIS LIMITED WARRANTY. ALL RIGHTS TO CONSEQUENTIAL OR
INCIDENTAL DAMAGES (INCLUDING CLAIMS FOR LOST SALES, LOST PROFITS, PRODUCT LOSS,
PROPERTY DAMAGES OR SERVICE EXPENSES) ARE EXPRESSLY EXCLUDED. THE EXPRESS
WARRANTIES MADE IN THIS LIMITED WARRANTY MAY NOT BE ALTERED, ENLARGED, OR CHANGED
BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON, WHATSOEVER.
LEGAL REMEDIES
The owner must notify Taylor in writing, by certified or registered letter to the following address, of any defect or
complaint with the Part, stating the defect or complaint and a specific request for repair, replacement, or other
correction of the Part under warranty, mailed at least thirty (30) days before pursuing any legal rights or remedies.
Taylor Company
a division of Carrier Commercial Refrigeration, Inc.
750 N. Blackhawk Blvd.
Rockton, IL
61072, U.S.A.
+ Available Separately
Model 161
Parts List
140409
016127F000
DESCRIPTION
PART
NUMBER
QTY.
WARR.
CLASS
COMMENTS
ACTUATOR-SWITCH-PLASTIC
035609
2
103
DRAW SWITCH
ARM A.-SWITCH *162/168*
X30736
2
103
DRAW SWITCH
BEAD-RUBBER
010613-17
1
000
BEARING-FRONT
023262
2
000
BEARING-GUIDE
014496
2
000
BEATER A.-*150/152/162/16
X24689
2
103
BELT-AX24
055201
1
000
BELT-AX45
045311
1
000
BLOCK-TERMINAL 2P .25 SPA
069015
1
103
S/N M1096647 & UP - U/D 221
BLOCK-TERMINAL 7P GREEN
024156
1
103
S/N M1096647 & UP - U/D 221
BLOCK-TERMINAL 3P .25 SPADE
057201
1
103
M1096646 & PRIOR
BOARD-LOGIC-GEN 2.11 SD/CHM/DF
X65971-SER
1
212
SWITCH-MEMBRANE-5 POSITION
043217
2
000
BOARD-POWER-GEN 1 & 2
X69574-SER
2
212
REPLACED X32326-SER U/D 225
FUSE-.063A-250V-5X20MM-SLO BLO
051272
2
000
BOLT-CARRIAGE 1/4-20X3/4
012347
2
000
BRUSH-DBL END-PUMP & FEED
013072
1
000
BRUSH-DRAW VALVE 1"OD X 2
013073
1
000
BRUSH-MIX PUMP BODY-3" X
023316
1
000
BRUSH-REAR BRG 1"D X 2"LG
013071
1
000
BUSHING-SNAP 1 ID X 1-1/4OD
600288
1
000
BUSHING-SNAP 11/16 ID X 7/8O
010548
5
103
CONTROL BOX
BUSHING-SNAP 1-5/16ID X 1
017008
2
103
BUSHING-SPLIT 43/64ID X 7/8O
027691
2
103
CONTROL BOX
BUTTON-RESET-RED PLASTIC
055249
2
103
CABLE-RIBBON-PWR/RELAY-60 IN
032445
2
103
CAP-DESIGN 1.010"ID-6 POI
014218
3
000
CAPACITOR-START 72-88UF/330V
059757
2
103
CAPACITOR-RUN 10UF/370V
059998
2
103
CARD-CHECKOUT WARRANTY-5
033941-W5
1
000
+ Available Separately
34
Parts List
Model 161
DESCRIPTION
COMMENTS
WARR.
CLASS
QTY.
PART
NUMBER
COMPRESSOR L63B562BBCB
048727-27E
1
512
+CAPACITOR-START 161-193UF/25
031790
1
103
+CAPACITOR-RUN 30UF/370V
038487
1
103
+RELAY-START-COMPRESSOR
047067
1
103
+GROMMET-COMPRESSOR MOUNTI
037428
4
000
+SLEEVE-MOUNTING-COMP.
039924
4
000
+SCREW-5/16-18X1-1/2 HEX H
001894
4
000
COMPRESSOR PL35G
055187-27
1
512
+CAPACITOR-START 60UF-220/
047703
1
000
+RELAY-START-COMPRESSOR-PL
055358
1
000
+KIT-MOUNTING-COMPRESSOR
047704
1
000
CONDENSER-AC 7X6X1.25-2 ROW
027155
1
103
DANFOSS
+DRYER-CAP. TUBE .021 ID X 9F
055522
1
000
DANFOSS
+SCREW-1/4-20X1 HEX HEAD C
017254
4
000
CONDENSER-AC 12LX16HX2.5T
048935
1
103
CONDENSER-AC 7X6X1.25-2 ROW
027155
1
103
CONTACTOR 230VAC 1PH 50/60HZ
055248-27
3
103
CORD-POWER-250V-15A-120"L
068754-27
1
103
S/N M0093177 & UP
COUPLING-3/8FS X 1/4FS
031791
4
103
COVER A.-HOPPER
X37963-SER
1
103
DECAL-DEC-TAYLOR 161 GEN
055511
1
000
DECAL-INST-CLN HPR
019029
1
000
DECAL-TROUBLESHOOT
038374
1
000
DIAGRAM-WIRING *161*
063820-27S
1
000
DOOR A.-3SPT 1.5QT VALOX W/BAF
X56906SER1
1
103
DOOR A.-MAGNET *161*
X56775
1
103
ROD A.-BAFFLE
X57200
2
103
+CAP-DESIGN 1.010"ID-6 POI
014218
3
000
+O-RING-2-3/4 OD X .139W
019998
2
000
+HANDLE-DRAW VALVE
030564
3
103
+PIN A.-PIVOT *168-LONG*
X38538
1
103
+ Available Separately
Model 161
Parts List
DESCRIPTION
COMMENTS
WARR.
CLASS
QTY.
PART
NUMBER
+O-RING-5/16 OD X .070W
016272
1
000
+PIN A.-PIVOT *168-SHORT*
X38539
1
103
+O-RING-5/16 OD X .070W
016272
1
000
+VALVE-DRAW *150-2*
024763
2
103
+O-RING-7/8 OD X .103W
014402
4
000
+VALVE-DRAW-CENTER *TM*
031164
1
103
+SEAL-DRAW VALVE *SMALL H-RING
030930
1
000
DRYER-CAP. TUBE .021 ID X 9F
055522
1
000
DANFOSS
DRYER-FILTER 1/4 X 1/4 SOLDE
048878
1
000
LINE LIQ HTE DRY
DVD-OPS TRAIN VIDEO *0161
066821-DVD
1
000
EXCHANGER A.-HEAT *161*AC
X64357
1
103
FAN-3 BLADE 12 " PULL 24D
063397
1
103
FASTENER-CLIP 1/4-20 U-TY
045865
8
103
FILTER-AIR 13.5X17.75X7/1
042703
1
000
GASKET-BASE PAN *161*
055815
1
000
+SCREW-10X7/16 UNSL TD HWH
066234
12
000
GASKET-BASE PAN
GASKET-HOPPER COVER-8QT
037042
1
000
GEAR A.*REDUCER 4 TO 1 SERVICE
025770-SER
2
212
+SCREW-1/4-20X3 HEX HEAD C
025984
4
000
+SCREW-1/4-20X3-1/4 HEX HE
025985
4
000
GUARD-FAN
028534-1
1
103
DANFOSS
HARNESS-WIRE-CONTROL BOX
069129-27
1
103
S/N M1096647 & UP - U/D 221
HARNESS-WIRE-MAIN *161*
069219-27
1
103
S/N M1096647 & UP - U/D 221
HARNESS-TRANS/RELAY *161*
069278-27
1
103
S/N M1096647 & UP - U/D 221
HARNESS-WIRE-CONTROL *161*
055838-27
1
103
M1096646 & PRIOR
HARNESS-WIRE-MAIN *161*
063573-27
1
103
M1096646 & PRIOR
HARNESS-WIRE-CAP/RELAY *161*
063975-27
1
103
HARNESS-WIRE-DANFOSS *161*
063563
1
103
INTERLOCK A.-DOOR *161*
X68046
1
103
S/N M1096647 & UP - U/D 221
KIT A.-MOTOR-FAN
X62253-27
1
103
+FAN-3 BLADE 12 " PULL 24D
063397
1
103
+ Available Separately
36
Parts List
Model 161
DESCRIPTION
COMMENTS
WARR.
CLASS
QTY.
PART
NUMBER
KIT A.-TUNE UP*162-168*
X31167
1
000
BEARING-FRONT
023262
2
000
BEARING-GUIDE
014496
2
000
CAP-DESIGN 1.010"ID-6 POINT
014218
3
000
SEAL-U-CUP
080534
2
000
5/16/12 & UP - REPLACES 21278
O-RING-2-3/4 OD X .139W
019998
2
000
O-RING-5/16 OD X .070W
016272
2
000
O-RING-7/8 OD X .103W
014402
4
000
SEAL-DRAW VALVE *SMALL H-RIN
030930
1
000
TOOL-O-RING REMOVAL-FREEZER
048260VWHT
1
000
LABEL-CAUTION-GRD-PERM-EN
032164
1
000
LABEL-DOOR-MOVE PART
032749
1
000
LABEL-SW-POWER-OFF/ON-SYM
052632
1
000
LABEL-WARN-CONDENSER-SHAR
059287
2
000
LABEL-WARN-COVER
051433
5
000
LABEL-WARN-ELEC-TW-SMALL
032718
1
000
LUBRICANT-TAYLOR 4 OZ.
047518
1
000
MAN-OPER 161
055155-M
1
000
MOTOR-1/2 HP REMOTE CAPS
055097-27G
2
212
+SCREW-5/16-18X5/8 SERR. F
017326
8
000
BEATER MOTOR
MOTOR-FAN 50 WATT W/GROUN
029770-27
1
103
MOTOR-FAN 95.3 CFM 2700 RPM
062253-27
N/A
SEE - KIT A.-MOTOR-FAN
NUT-5/16-18 WHIZ FLANGE N
017327
4
000
NUTSERT-10-32/.020-.130 G
047597
6
000
NUT-STUD *161-162-168*
056802
2
000
O-RING-13/16 OD X .139W
021278
2
000
OVERLOAD-THERMAL-2P-2.4/3.6A
055249-27G
2
103
PAIL-6 QT.
023348
1
000
PAN-DRIP *161*
055206
2
103
PANEL A.-FRONT *161*
X58488
1
103
+SCREW-10-32X1/2 SERRATED
020982
4
000
PANEL-FRONT
+ Available Separately
Model 161
Parts List
DESCRIPTION
COMMENTS
WARR.
CLASS
QTY.
PART
NUMBER
PANEL A.-SIDE RIGHT *161*
X58490
1
103
+SCREW-10-32X3/8 SLTD TRUS
024298
2
000
PANEL-SIDE
PANEL-LOWER-FRONT *161*
058493
1
103
PANEL-REAR *161*AC
058492
1
103
PANEL-SIDE-LEFT *161*
058491
1
103
+SCREW-1/4-20X3/8 SLTD ROU
011694
8
000
PANELS
PLATE-DEC *161* GENII
055512
1
103
+SCREW-6-32X3/8 SLTD BINDE
002201
2
000
DEC PLATE
+SCREW-10-24X1/2 TORX TRUS
002077
6
000
DEC PLATE
PROBE-THERMISTOR-BARREL-2% T
038061-BLK
1
103
PROBE A.-THERMISTOR
X31602
2
103
PULLEY-5.7" PITCH DIA X 5
041498
2
103
PULLEY-AK20X5/8
041162
2
103
RELAY-DPDT 100UA TO 7A 1/8HP
052111-03
1
103
S/N M1096647 & UP - U/D 221
RELAY-DPDT 100UA TO 7A
052111-76
2
103
S/N M1096647 & UP - U/D 221
+SOCKET-RELAY-FOR USE W/05
052112
3
103
S/N M1096647 & UP - U/D 221
SANITIZER-STERA SHEEN -GREEN
055492
1
000
SHELL A.-INSULATED *161*
X68407-SER
1
512
S/N M1084472 AND UP
STUD-NOSE CONE-5/16-18X5/16-18
013496
2
103
+NUT-STUD *161-162-168*
056802
2
103
SHELL A.-INSULATED *161*
X58457-SER
1
512
S/N M1084471 AND PRIOR
+NUT-STUD *161-162-168*
056802
2
103
+STUD-NOSE CONE-5/16-18X5/16-18
013496
2
103
+STUD-NOSE CONE-*SPCL
NPN
2
M0023521-M0023537 SEE C HARPER
SHIELD-SPLASH *5454-8-752
022765
1
103
SHROUD-CONDENSER *161*
064356
1
103
SHROUD DANFOSS *060*710*
048818
1
103
SPRING-COMP.720X.063X2.00
023664
2
103
DRAW SWITCH
SWITCH A.-DRAW *161*
X55234-SER
2
103
BEARING-SWITCH
029244
2
000
BRACKET-SWITCH *168*
035524
1
103
+ Available Separately
38
Parts List
Model 161
DESCRIPTION
COMMENTS
WARR.
CLASS
QTY.
PART
NUMBER
INSULATOR-SWITCH 1/64 ARMITE
029099
1
000
NUT-PUSH ON-1/2DIA. SHAFT
039735
2
000
SCREW-4-40X5/8 SLTD ROUND
027219
2
000
SWITCH-LEVER-SPDT-15A-125-25
027214
1
103
+ACTUATOR-SWITCH-PLASTIC
035609
2
103
DRAW SWITCH
+ARM A.-SWITCH *162/168*
X30736
2
103
DRAW SWITCH
+SPRING-COMP.720X.063X2.00
023664
2
103
DRAW SWITCH
+E-RING-1/4 IN-ZD
034962
2
000
SWITCH-PRESSURE 405 PSI-SOLD
052663
1
103
LINE DISCHARGE
SWITCH-TOGGLE-4PDT*ON-NONE-ON
037394
1
103
SWITCH A.-POWER
TEE-1/4S-COPPER
003949
1
000
TERMINAL-FEM.SP.22-18 .25
015850-L
13
103
TERMINAL-FEM.SP.INS.16-14
023959-L
3
000
TERMINAL-LOW VOLTAGE GROU
034455
2
000
TRAY-DRIP 16-7/8L X 4-15/
020157-SP
1
103
TUBE-FEED-.166 HOLE-SS-TM
030797
2
103
VALVE-ACCESS 1/4FL X 1/4SOLD
044404
1
103
LINE SUCTION DANF
VALVE-ACCESS-1/4MFL X 3/8ODS
053565
2
103
LINE ACCESS DISCCHG/LOW
VALVE-ACCESS-1/4 MFLX1/4
047016
1
103
VALVE-EPR 1/4S
022665
1
103
LINE SUCTION DANF
VALVE-EXP-AUTO-1/4S X1/4
046365
2
103
+BOOT-VALVE-EXPANSION
050900
2
000
VALVE-SOL-1/4 ORFX3/8IN-1/2O
062019-27
2
103
LINE SUCTION SOL
VALVE-SOLENOID 7/64ORF X 1/4
043449-27
2
103
LINE LIQUID SOLENOID
WASHER-3/8 USS FLAT CR3
000653
8
000
WASHER-5/16 SAE FLAT CR3
017660
8
000
WASHER-5/16 USS FLAT CR3
000651
4
000
WATER COOLED
ADAPTOR-3/8MP X 1/2 BARB-
011021
2
103
BRACKET A.-FITTING *161*W
X63791
1
103
+ Available Separately
Model 161
Parts List
DESCRIPTION
COMMENTS
WARR.
CLASS
QTY.
PART
NUMBER
BRACKET-VALVE-W/C *C708*
058440
1
103
CLAMP-HOSE 3/4 ID CONST T
067113
6
000
CONDENSER-WC-SPIRAL 11-1/2 O
049309
1
103
ELBOW-3/8MP X 1/2 BARB-BR
018641
2
103
HOSE-RUBBER 1/2 ID X 7/8 OD
R50200
5'
000
NUT-1/4-20 WHIZ FLANGE LO
017523
4
000
PANEL-REAR *161*WC*
063837
1
103
PANEL-SIDE *161*R*WC*
063838
1
103
SWITCH-PRESSURE 350 PSI-S
048231
1
103
VALVE-WATER 3/8 REG/HEAD
046686
1
103
50HZ (STANDARD-ROHS)
-40
220-240V 50HZ 1PH
BLOCK-TERMINAL 7P GREEN
024156
1
103
220-240V 50HZ 1PH
CORD-1.5MM-3 HAR7 16GA 60
051656-95
1
103
220-240V 50HZ 1PH - STANDARD
CORD-POWER HARMONIZED *42
066395-95
1
103
220-240V 50HZ 1PH - ROHS
INDICATOR-DIGITAL TEMP-SO
051356
2
DIGITAL THERMOMETER
DIAGRAM-WIRING *161*
063820-40S
1
000
220-240V 50HZ 1PH
DVD-OPS TRAIN VIDEO*TAYLO
037665-DVD
1
000
220-240V 50HZ 1PH - STANDARD
DVD-OPS TRAIN VIDEO *0161
066821-DVD
1
000
220-240V 50HZ 1PH - ROHS
COMPRESSOR L63B562BBKB
048727-40E
1
512
220-240V 50HZ 1PH
+CAPACITOR-RUN 15UF/370V
027087
1
103
220-240V 50HZ 1PH
+CAPACITOR-START-88-108UF/
059759
1
103
220-240V 50HZ 1PH
+RELAY-START-COMPRESSOR
048766
1
103
220-240V 50HZ 1PH
HARNESS-WIRE-MAIN *161*
063573-40
1
103
220-240V 50HZ 1PH
HARNESS-WIRE-CAP/RELAY *1
063975-40
1
103
220-240V 50HZ 1PH
MOTOR-1/2 HP REMOTE CAPS
055097-40G
2
212
220-240V 50HZ 1PH
OPTIONAL ITEMS
INDICATOR-DIGITAL TEMP-SO
051356
2
103
KIT A.-CONE DISPENSER-4 TUBE
X41141
1
103
KIT A.-LEG/AIR SKIRT *161
X64119
1
103
KIT A.-HOPPER LOCK TWIN *
X66359
1
103
+ Available Separately
40
Parts List
Model 161
DESCRIPTION
COMMENTS
WARR.
CLASS
QTY.
PART
NUMBER
LEG-4" 3/8-16 STUD
036397
4
103
PANEL-LOWER-FRONT *161*
058493-SP2
2
103
+SCREW-8-32X3/8 UNSLTD HEX
041951
4
000
PANEL-SKIRT-AIR *161*
055508
1
103
TUBE-FEED-.219 HOLE-SS-TM
030797-4
2
103
SPECIAL MIX FEED TUBES
MARINE USE
BLOCK-TERMINAL 7P GREEN
024156
1
105
DIAGRAM-WIRING *161*
063820-40S
1
000
HARNESS-WIRE-CAP/RELAY *1
063975-40
1
105
HARNESS-WIRE-MAIN *161*
063573-40
1
105
PANEL A.-FRONT *161*
X58488-SPN
1
103
PANEL A.-SIDE RIGHT *161*
X58490-SPN
1
103
PANEL-LOWER-FRONT *161*
058493-SPN
1
103
PANEL-REAR *161*AC
058492-SPN
1
103
PANEL-SIDE-LEFT *161*
058491-SPN
1
103
PLATE-DEC *161* GENII
055512-SPN
1
103
SHIELD-SPLASH *5454-8-752
022765-SPN
1
103
M 161 CHINA
BLOCK-TERMINAL 7P GREEN
024156
1
103
BRUSH-DBL END-PUMP&FEED T
C00101
1
000
BRUSH-DRAW VALVE 1"OD X 2
C00104
1
000
BRUSH-MIX PUMP BODY-3"X7"
C00032
1
000
REPLACES 023316 8/25/11
BRUSH-REAR BRG 1"D X 2"LG
C00100
1
000
COMPRESSOR L63B562BBKB
048727-40E
1
512
+CAPACITOR-RUN 15UF/370V
027087
1
103
+CAPACITOR-START-88-108UF/
059759
1
103
+RELAY-START-COMPRESSOR
048766
1
103
CAP-DESIGN 1.010"ID-6 POINT
014218
3
000
CORD-POWER HARMONIZED *42
066395-95
1
103
COUPLING-3/8FS X 1/4FS
031791
2
103
+ Available Separately
Model 161
Parts List
DESCRIPTION
COMMENTS
WARR.
CLASS
QTY.
PART
NUMBER
DECAL-INST-CLN HPR-CHINES
019029-CH
1
000
DECAL-TROUBLESHOOT-CHINES
038374-CH
1
000
DIAGRAM-WIRING *161*
063820-40S
1
000
DRYER-FILTER 1/4 X 1/4 SO
048878
1
000
FORM-QUALITY REPORT BY FA
065712-SCH
1
000
GEAR A.*REDUCER 4 TO 1 SE
025770-SER
2
212
HARNESS-WIRE-CAP/RELAY *1
063975-40
1
103
HARNESS-WIRE-MAIN *161*
063573-40
1
103
INSTRUCTION-INSTALL-CHINE
056904CINS
1
000
INSTRUCTION-WEEE END OF L
064371-INS
1
000
KIT A.-TUNE UP*162-168*
X31167
1
000
LABEL-ATTN SVC ENG-CHINES
015068-CH
2
000
LABEL-CAUTION-GRD-PERM-CH
032164-CH
1
000
LABEL-DOOR-MOVE PART-CHINESE
032749-CH
1
000
LABEL-WARN-COVER-CHINESE
051433-CH
5
000
LABEL-WARN-ELEC-TW-SMALL
032718-CH
1
000
LUBRICANT-TAYLOR 4 OZ.
047518
1
000
MAN-OPER 161 CHINESE
055155CM
1
000
MOTOR-1/2 HP REMOTE CAPS
055097-40G
2
212
PROBE-THERMISTOR-BARREL-2% T
038061-BLK
1
103
PROBE A.-THERMISTOR
X31602
2
103
PULLEY-5.7" PITCH DIA X 5
C00186
2
103
PULLEY-AK20X5/8
C00185
2
103
SANITIZER-STERA SHEEN-GRE
C00001
1
000
SWITCH-PRESSURE 405 PSI-S
052663
1
103
TUBE-FEED-.166 HOLE-SS-TM
030797
1
103
VALVE-ACCESS-1/4MFL X 3/8
053565
2
103
VALVE-SOL-1/4 ORFX3/8IN-1
062019-27
2
103
VALVE-SOLENOID 7/64ORF X
043449-27
2
103
2014 Carrier Commercial Refrigeration, Inc.
c
C
C
C
N0
NC
T
T
C
N0
NC
T
L1
L2
WINDING
PROTECTOR
(INTERNAL)
MAIN
WINDING
START
WINDING
START
RELAY
START
CAPACITOR
14
12
13
10
11
COMPRESSOR WIRING
(MODEL W/HST)
START
RELAY
START
WINDING
MAIN
WINDING
WINDING
PROTECTOR
(INTERNAL)
L2
L1
COMPRESSOR WIRING
(MODEL W/HST)
11
10
13
12
14
C
GRN/YEL
C
GREEN/YELLOW
RIGHT BEATER
MOTOR (FIG.2 & 4)
GREEN/YELLOW
GROUND FRAME SECURELY
ORN
M
MAIN CONDENSER
BLACK
CORD
FAN MOTOR
(A.C. UNIT ONLY)
L1
2
L2
BLK
GRN/YEL
BLK
LEESON
.5 HP BEATER MOTOR
(055097-27)
SEE NOTE 1
S
R
YEL/BLU T6
YEL/BLK T9
YEL
YEL T5
YEL T5
BLK CORD
S
R
WHT
A. O. SMITH
EXTERNAL B/M
CAPACITORS
ORN
WHT
GRA
BLK
4
4
1
BLK
GRN/YEL
A. O. SMITH
.5 HP BEATER MOTOR
(055097-27)
SEE NOTE 1
T5
T8
2
BLK
NOTE:
1. FOR CCW ROTATION OF A. 0. SMITH
BEATER MOTOR CONNECT INTERNAL
RED TO TERMINAL 4 & INTERNAL
BLACK TO TERMINAL 2.
RED
(INTERNAL)
BLACK
(INTERNAL)
GE/RBC BEATER MOTOR WIRING
CCW ROTATION AS SHOWN, TO REVERSE ROTATION
INTERCHANGE YELLOW AND BLUE
T4 OR YEL
T8 OR RED
THERMAL OL
4
2
LINE
T1 OR BLU
A
P2 OR BRN
P1 OR PUR
MAIN
START
5
1
1
2
3
RUN
CAPACITOR
S
R
BLK OR J9
RBC/GE
EXTERNAL B/M
CAPACITORS
BLK OR T5
BRN OR J11
PUR OR J12
J11 OR BRN
T5 OR BLK
LINE
J9 OR BLK
J12 OR PUR
M
SHR FAN MOTOR
WHT/BLK
WHT
FIG. 1
S
R
LINE
RELAY
START CAPACITOR
C
INTERNAL OVERLOAD
RUN CAPACITOR
BRISTOL SCHEMATIC WIRING DIAGRAM - CSR
1
2
5
4
WHITE
BROWN
BLACK
EQUIPMENT
GROUND
BLEED RESISTOR
START
CAPACITOR
L1
T1
L1
M
T2
L2
MAIN
COMPRESSOR
(FIG. 1)
BLK
WHT
WHT
MIX
FAN
PUMP
BTR
COM
O.L.
L2
L1
GND
1
CABLE
LEFT
POWER BOARD
MIN
MAX MIN
MAX MIN
MAX
S.S. VISCOSITY
SHAKE TEMP.
MIX
STANDBY
MIX
STANDBY WASH
AUTO
PUMP
SET POINT MIX LOW MIX OUT
MIX
LOW
MIX
OUT
DRAW SHK
PUMP
MIX 1
BRL
PROBE
FAN
MIX 2
A
BEATER
A
L2
LEFT
DRAW
SWITCH
LEFT MIX
PROBE
PRP
LEFT STANDBY
THERMISTOR PROBE
BLK
BLK
WHT
BLK
BRN
WHT
GRN/YEL
GRN/YEL
MAIN
COMPRESSOR
CONTACTOR
MAIN
COMPRESSOR CONTACTOR
M
T3
L3
LEFT BEATER
MOTOR (FIG. 2)
BLK
WHT
LEFT BEATER
MOTOR STARTER
BLK
L1
T1
BLK
BLU
BLU/WHT
LEFT BEATER
MOTOR STARTER
WHT
RIBBON CABLE
BRN
M
SHR COMPRESSOR
(FIG. 3)
WHT/BLK
WHT
MIX
THERMISTOR PROBE
BLK
240K
WHT
LEFT BEATER
MOTOR STARTER
A1
A2
LEFT LIQUID
LINE SOLENOID VALVE
LEFT SUCTION
LINE SOLENOID VALVE
MAIN
COMPRESSOR CONTACTOR
A1
A2
WHT
MIX
FAN
PUMP
BTR
COM
O.L.
L2
L1
GND
CABLE
RIGHT
POWER BOARD
MIN
MAX MIN
MAX MIN
MAX
S.S. VISCOSITY
SHAKE TEMP.
MIX
STANDBY
MIX
STANDBY WASH
AUTO
PUMP
SET POINT MIX LOW MIX OUT
MIX
LOW
MIX
OUT
DRAW SHK
PUMP
MIX 1
BRL
PROBE
FAN
MIX 2
A
BEATER
A
RIGHT
DRAW
SWITCH
RIGHT MIX
PROBE
PRP
RIGHT STANDBY
THERMISTOR PROBE
BLK
BLACK
WHT
BLK
BRN
GRN/YEL
M
T3
L3
BLK
WHT
RIGHT BEATER
MOTOR STARTER
BLK
L1
T1
BLK
RIGHT BEATER
MOTOR STARTER
WHT
RIBBON CABLE
RIGHT BEATER
MOTOR STARTER
A1
A2
RIGHT LIQUID
LINE SOLENOID VALVE
RIGHT SUCTION
LINE SOLENOID VALVE
WHT
WHT
BRN
PRP
NO MIX LEVEL
(OPTION)
WHT
PRP
NO MIX LEVEL
(OPTION)
BRN
CONTROL
SWITCH
4PDT
WHT
WHT
WHT
ORN/WHT
RED/WHT
ORN/WHT
WHT
WHT
WHT
ORN
ORN
BLK
BLK
BRN
BLK
BLU/WHT
BLK
BLK
BLK
WHT
LEFT LOGIC BOARD
RIGHT LOGIC BOARD
WHT
FIG. 2
FIG. 3
FIG. 4
ON
OFF
ON
OFF
ON
OFF
YEL
ON
OFF
13
14
RIGHT COMPRESSOR
ENABLE RELAY
13
14
LEFT COMPRESSOR
ENABLE RELAY
9
5
9
5
RED/BLK
WHT
BLK
BLK/YEL
RED/BLK
RED/WHT
BLK
BLK/YEL
BLK/YEL
RED/BLK
BLK/YEL
BLK
ORN
BLK
BLU/WHT
BLU/WHT
BRN
WHT
HPCO
LEFT BEATER
OVERLOAD SWITCH
95
96
RIGHT BEATER
OVERLOAD SWITCH
BRN
BRN/WHT
95
96
BLK CORD
BLK
WHT
YEL
14
13
N. O.
DOOR
INTERLOCK
SWITCH
DOOR
INTERLOCK
RELAY
BRN
9
5
1
DOOR INTERLOCK
RELAY
12
8
4
DOOR INTERLOCK
RELAY
24 VLT
YEL
WHT
BRN
BLU/WHT
WHT
BLK
BRN/WHT
BLK
CORD
BLK
BLK
BLK
BLK/YEL
WHT
BRN
TECUMSEH SCHEMATIC WIRING DIAGRAM - CSR
LEESON
EXTERNAL B/M
CAPACITORS
GRN/YEL
BLK
WHT
208/230 VOLTS, 60HZ
(DOMESTIC)
L1
L2
208/230 VOLTS, 60HZ
(INTERNATIONAL)
L1
L2 OR N
WIRE COLORS - BASED ON INCOMING POWER
FIG. 5
BRN
BLU
(SEE FIG. 5)
EQUIPOTENTIAL
GROUND
2014 Carrier Commercial Refrigeration, Inc.
c
GROUND FRAME SECURELY
L1
T1
L1
M
T2
L2
MAIN
COMPRESSOR
(FIG. 1)
BLK
WHT
WHT
MIX
FAN
PUMP
BTR
COM
O.L.
L2
L1
GND
1
CABLE
LEFT
POWER BOARD
MIN
MAX MIN
MAX MIN
MAX
S.S. VISCOSITY
SHAKE TEMP.
MIX
STANDBY
MIX
STANDBY WASH
AUTO
PUMP
SET POINT MIX LOW MIX OUT
MIX
LOW
MIX
OUT
DRAW SHK
PUMP
MIX 1
BRL
PROBE
FAN
MIX 2
A
BEATER
A
C
C
L2
C
N0
NC
LEFT
DRAW
SWITCH
LEFT MIX
PROBE
PRP
T
LEFT STANDBY
THERMISTOR PROBE
BLK
BLK
WHT
BLK
BRN
WHT
GRN/YEL
GRN/YEL
MAIN
COMPRESSOR
CONTACTOR
MAIN
COMPRESSOR CONTACTOR
M
T3
L3
LEFT BEATER
MOTOR (FIG. 2)
BLK
WHT
LEFT BEATER
MOTOR STARTER
BLK
L1
T1
BLK
BLU
BLU/WHT
LEFT BEATER
MOTOR STARTER
WHT
RIBBON CABLE
BRN
M
SHR COMPRESSOR
(FIG. 3)
WHT/BLK
WHT
T
MIX
THERMISTOR PROBE
BLK
240K
WHT
LEFT BEATER
MOTOR STARTER
A1
A2
LEFT LIQUID
LINE SOLENOID VALVE
LEFT SUCTION
LINE SOLENOID VALVE
MAIN
COMPRESSOR CONTACTOR
A1
A2
WHT
MIX
FAN
PUMP
BTR
COM
O.L.
L2
L1
GND
CABLE
RIGHT
POWER BOARD
MIN
MAX MIN
MAX MIN
MAX
S.S. VISCOSITY
SHAKE TEMP.
MIX
STANDBY
MIX
STANDBY WASH
AUTO
PUMP
SET POINT MIX LOW MIX OUT
MIX
LOW
MIX
OUT
DRAW SHK
PUMP
MIX 1
BRL
PROBE
FAN
MIX 2
A
BEATER
A
C
N0
NC
RIGHT
DRAW
SWITCH
RIGHT MIX
PROBE
PRP
T
RIGHT STANDBY
THERMISTOR PROBE
BLK
BLACK
WHT
BLK
BRN
GRN/YEL
M
T3
L3
BLK
WHT
RIGHT BEATER
MOTOR STARTER
BLK
L1
T1
BLK
RIGHT BEATER
MOTOR STARTER
WHT
RIBBON CABLE
RIGHT BEATER
MOTOR STARTER
A1
A2
RIGHT LIQUID
LINE SOLENOID VALVE
RIGHT SUCTION
LINE SOLENOID VALVE
WHT
WHT
BRN
PRP
NO MIX LEVEL
(OPTION)
WHT
PRP
NO MIX LEVEL
(OPTION)
BRN
CONTROL
SWITCH
4PDT
WHT
WHT
WHT
ORN/WHT
RED/WHT
ORN/WHT
WHT
WHT
WHT
ORN
ORN
BLK
BLK
BRN
BLK
BLU/WHT
BLK
BLK
BLK
WHT
LEFT LOGIC BOARD
RIGHT LOGIC BOARD
WHT
C
GRN/YEL
C
GRN/YEL
RIGHT BEATER
MOTOR (FIG.2 & 4)
GREEN/YELLOW
ORN
M
MAIN CONDENSER
BLACK
CORD
FAN MOTOR
(A.C. UNIT ONLY)
BLK CORD
M
SHR FAN MOTOR
WHT/BLK
WHT
ON
OFF
ON
OFF
ON
OFF
YEL
ON
OFF
13
14
RIGHT COMPRESSOR
ENABLE RELAY
13
14
LEFT COMPRESSOR
ENABLE RELAY
9
5
9
5
RED/BLK
WHT
BLK
BLK/YEL
RED/BLK
RED/WHT
BLK
BLK/YEL
BLK/YEL
RED/BLK
BLK/YEL
BLK
ORN
BLK
BLU/WHT
BLU/WHT
BRN
WHT
HPCO
LEFT BEATER
OVERLOAD SWITCH
95
96
RIGHT BEATER
OVERLOAD SWITCH
BRN
BRN/WHT
95
96
BLK CORD
BLK
WHT
YEL
14
13
N. O.
DOOR
INTERLOCK
SWITCH
DOOR
INTERLOCK
RELAY
BRN
9
5
1
DOOR INTERLOCK
RELAY
12
8
4
DOOR INTERLOCK
RELAY
24 VLT
YEL
WHT
BRN
BLU/WHT
WHT
BLK
BRN/WHT
BLK
CORD
BLK
BLK
BLK
BLK/YEL
WHT
BRN
GRN/YEL
GRN/YEL
GRN/YEL
ELECTRICAL
ENCLOSURES
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
L1
L2
WINDING
PROTECTOR
(INTERNAL)
MAIN
WINDING
START
WINDING
START
RELAY
START
CAPACITOR
14
12
13
10
11
COMPRESSOR WIRING
(MODEL W/HST)
START
RELAY
START
WINDING
MAIN
WINDING
WINDING
PROTECTOR
(INTERNAL)
L2
L1
COMPRESSOR WIRING
(MODEL W/HST)
11
10
13
12
14
L1
2
L2
BLK
GRN/YEL
BLK
LEESON
.5 HP BEATER MOTOR
(055097-27)
SEE NOTE 1
S
R
YEL/BLU T6
YEL/BLK T9
YEL
YEL T5
YEL T5
4
4
1
BLK
GRN/YEL
A. O. SMITH
.5 HP BEATER MOTOR
(055097-27)
SEE NOTE 1
T5
T8
2
BLK
RED
(INTERNAL)
BLACK
(INTERNAL)
GE/RBC BEATER MOTOR WIRING
CCW ROTATION AS SHOWN, TO REVERSE ROTATION
INTERCHANGE YELLOW AND BLUE
T4 OR YEL
T8 OR RED
THERMAL OL
4
2
LINE
T1 OR BLU
A
P2 OR BRN
P1 OR PUR
MAIN
START
5
1
1
2
3
RUN
CAPACITOR
S
R
BLK OR J9
RBC/GE
EXTERNAL B/M
CAPACITORS
BLK OR T5
BRN OR J11
PUR OR J12
J11 OR BRN
T5 OR BLK
LINE
J9 OR BLK
J12 OR PUR
FIG. 1
S
R
LINE
RELAY
START CAPACITOR
C
INTERNAL OVERLOAD
RUN CAPACITOR
BRISTOL SCHEMATIC WIRING DIAGRAM - CSR
1
2
5
4
WHITE
BROWN
BLACK
EQUIPMENT
GROUND
BLEED RESISTOR
START
CAPACITOR
FIG. 2
FIG. 3
FIG. 4
TECUMSEH SCHEMATIC WIRING DIAGRAM - CSR
EXTERNAL B/M
CAPACITORS
(SEE FIG. 5)
EQUIPOTENTIAL