DUAL MINI INFRARED

EMITTER Information and Installation Guide To block remote control signals from other emitters or local remote controls cut black window mask to the component window size and also cover IR34 cover plate. Black Window Mask IR34 IR34 Enlarged Side View Clear adhesive layer. Stick this side to component window. Replace adhesive if necessary. High output side. Used when IR34 is not stuck on component IR window. Controls components up to 3’ (1m) away. Wire Low output side. IR34 Plug and Wire Polarity + - + - Wire Tip Typical Installation To IR55 connection block Receiver Infared emitters low output (flat) side attached directly to IR sensor windows. Cabinet Installation Receiver Note: In this mode, other IR signals can pass through IR34’s and control component. To stop this cover the IR34’s and component sensor window with black tape. Shelf Shelf Note: In this mode, an emitter is placed at the front of the shelf either above or below the IR window. It is less reliable than direct attachment but looks better. Cabinet Installation Receiver side view Shelf Shelf Note: In this mode, an emitter is attached to the door of the equipment rack with the high output side facing the component IR window. Obviously the emitter will be less reliable when the rack door is open . Equipment Rack Door IR34 IR34 Caution: Emitters can easily be destroyed by connecting them directly to a power supply or battery. CD Player