Kramer Electronics, Ltd.

USER MANUAL Models: PT-110, XGA Line Transmitter WP-110, XGA Line Transmitter PT-120, XGA Line Receiver TP-120, XGA Line Receiver

PT-110 XGA Line Transmitter

2 3.2 WP-110 XGA Line Transmitter 2 3.3 PT-120 XGA Line Receiver 3 3.4 TP-120 XGA Line Receiver 3 3.5 About the Power Connect™ Feature 3 3.6 Shielded Twisted Pair (STP) / Unshielded Twisted Pair (UTP) 4 3.7 Achieving the Best Performance 4 4 Your XGA Line Transmitter(s) / Receiver 5 4.1 Your PT-110 XGA Line Transmitter 5 4.2 Your WP-110 XGA Line Transmitter 6 4.3 Your PT-120 XGA Line Receiver 7 4.4 Your TP-120 XGA Line Receiver 8 5 Using the XGA Line Transmitter(s) / Receiver 9 5.1 Installing the WP-110 XGA Line Transmitter 11 5.2 Wiring the CAT 5 LINE IN / LINE OUT RJ-45 Connectors 11 6 Technical Specifications 12 Figures Figure 1: PT-110 XGA Line Transmitter 5 Figure 2: WP-110 XGA Line Transmitter 6 Figure 3: PT-120 XGA Line Receiver 7 Figure 4: TP-120 XGA Line Receiver 8 Figure 5: XGA-to-Twisted Pair Transmitter and Receiver System via UTP Cable 10 Figure 6: CAT 5 PINOUT 11 Tables Table 1: PT-110 Features 5 Table 2: WP-110 XGA Line Transmitter Features 7 Table 3: PT-120 XGA Line Receiver Features 8 Table 4: TP-120 XGA Line Receiver Features 8 Table 5: CAT 5 PINOUT 11 Table 6: Technical Specifications of the PT-110 / WP-110 / PT-120 / TP-120 12

Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been

providing a world of unique, creative, and affordable solutions to the vast range of problems that confront the video, audio, presentation, and broadcasting professional on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better! Our 1,000-plus different models now appear in 11 groups1 that are clearly defined by function. Thank you for purchasing the Kramer Pico TOOLS PT-110 XGA Line Transmitter, Kramer Wall Plate WP-110 XGA Line Transmitter, Kramer Pico TOOLS PT-120 XGA Line Receiver, and/or Kramer TOOLS TP-120 XGA Line Receiver, which are ideal for: • Presentation and multimedia applications • Long range graphics distribution for schools, hospitals, security, and stores The package includes the following items: • PT-110 XGA Line Transmitter or WP-110 XGA Line Transmitter or PT-120 XGA Line Receiver or TP-120 XGA Line Receiver • Power adapter (12V DC Input) and this user manual2 2 Getting Started We recommend that you: • Unpack the equipment carefully and save the original box and packaging materials for possible future shipment • Review the contents of this user manual • Use Kramer high-performance high-resolution cables3 1 GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Matrix Switchers; GROUP 3: Control Systems; GROUP 4: Format/Standards Converters; GROUP 5: Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 7: Scan Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity; GROUP 10: Accessories and Rack Adapters; GROUP 11: Sierra Products 2 Download up-to-date Kramer user manuals from the Internet at http://www.kramerelectronics.com 3 The complete list of Kramer cables is on our Web site at http://www.kramerelectronics.com

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Overview 2 3 Overview This section describes: • A summary of the PT-110 XGA Line Transmitter, see section 3.1 • A summary of the WP-110 XGA Line Transmitter, see section 3.2 • A summary of the PT-120 XGA Line Receiver, see section 3.3 • A summary of the TP-120 XGA Line Receiver, see section 3.4 • The power connect feature, see section 3.5 • Using shielded twisted pair (STP) / unshielded twisted pair (UTP), see section 3.6 • Recommendations for achieving the best performance, see section 3.7 3.1 PT-110 XGA Line Transmitter Using an XGA Line Transmitter—the PT-110 or WP-110—with the PT-120 or TP-120 constitutes a VGA/XGA-to-Twisted Pair Transmitter and Receiver. The Kramer Pico TOOLS PT-110 is an XGA line transmitter that receives an XGA signal and transmits it over a CAT 5 cable to the PT-120 or TP-120 receiver. In particular, the PT-110: • Has a resolution of up to UXGA • Can use the simplest UTP CAT 5 cables, and performs even better with higher quality cables • Has the Power Connect feature • Is 12V DC fed 3.2 WP-110 XGA Line Transmitter The Kramer Wall Plate WP-110 is an XGA line transmitter—available in three versions: one for the USA, one for Belgium and Germany, and one for the UK and most of Europe1—that receives an XGA signal and transmits it over a CAT 5 cable to the PT-120 or TP-120 receiver. In particular, the WP-110: • Has a resolution of up to UXGA • Can use the simplest UTP CAT 5 cables, however, it benefits from better quality cables • Has the power connect feature • Is powered via a standard 12V DC feed 1 Excluding Belgium and Germany

PT-120 XGA Line Receiver

The Kramer Pico TOOLS PT-120 is an XGA line receiver that receives a coded CAT 5 signal transmitted by either the WP-110 or the PT-110, decodes it and converts it to an XGA output. In particular, the PT-120: • Has an operating range of more than 300ft (more than 100m) using standard CAT 5 cable and the WP-110 or the PT-110 • Includes EQ. and level controls • Has the power connect feature • Is 12V DC fed 3.4 TP-120 XGA Line Receiver The Kramer TOOLS TP-120 is an XGA line receiver that receives a coded CAT 5 signal transmitted by either the WP-110 or the PT-110, decodes it and converts it to an XGA output. In particular, the TP-120: • Has an operating range of more than 300ft (more than 100m) using standard CAT 5 cable and the WP-110 or the PT-110 • Includes EQ. and level controls • Has the power connect feature • Is 12V DC fed 3.5 About the Power Connect™ Feature The Power Connect feature applies as long as the cable can carry power. This feature is available when using STP cable and the distance does not exceed 50m on standard CAT 5 cable. For longer distances, heavy gauge cable should be used1. For units which are connected via RJ-45 connectors, make sure that the shield of the STP cable is connected to the metal casing of the connectors on both ends of the cable. For units which are connected via terminal block connectors, the shield of the STP cable must be connected to a ground terminal on the units at both ends (use the ground terminal of the power supply connection if necessary). For a CAT 5 cable exceeding a distance of 50m, separate power supplies should be connected to the transmitter and to the receiver simultaneously. 1 CAT 5 cable is still suitable for the video/audio transmission, but not for feeding the power at these distances

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Overview 4 3.6 Shielded Twisted Pair (STP) / Unshielded Twisted Pair (UTP) We recommend that you use Shielded Twisted Pair (STP) cable. There are different levels of STP cable available, and we advise you to use the best quality STP cable that you can afford. Our non-skew-free cable, Kramer BC-STP is intended for analog signals where skewing is not an issue. For cases where there is skewing, our UTP skew-free cable, Kramer BC-XTP, may be used. Bear in mind, though, that we advise using STP cables where possible, since the compliance to electromagnetic interference was tested using those cables. Although Unshielded Twisted Pair (UTP) cable might be preferred for long range applications, the UTP cable should be installed far away from electric cables, motors and so on, which are prone to create electrical interference. However, since the use of UTP cable might cause inconformity to electromagnetic standards, Kramer does not commit to meeting the standard with UTP cable. 3.7 Achieving the Best Performance To achieve the best performance: • Use only good quality connection cables1 to avoid interference, deterioration in signal quality due to poor matching, and elevated noise levels (often associated with low-quality cables). • Avoid interference from neighboring electrical appliances that may adversely influence signal quality and position your Kramer XGA Line Transmitter(s) / Receiver away from moisture, excessive sunlight and dust 1 Available from Kramer Electronics on our Web site at http://www.kramerelectronics.com

Your XGA Line Transmitter(s) / Receiver

5 4 Your XGA Line Transmitter(s) / Receiver This section defines the XGA Line Transmitter(s) / Receiver: • PT-110 XGA Line Transmitter (see section 4.1) • WP-110 XGA Line Transmitter (see section 4.2) • PT-120 XGA Line Receiver (see section 4.3) • TP-120 XGA Line Receiver (see section 4.4) 4.1 Your PT-110 XGA Line Transmitter Figure 1 and Table 1 define the PT-110: Figure 1: PT-110 XGA Line Transmitter Table 1: PT-110 Features # Feature Function 1 12V DC +12V DC connector for powering the unit 2 XGA INPUT 15-pin HD F Connector Connect to the XGA source 3 LINE OUT RJ-45 Connector Connects to the LINE IN RJ-45 connector on the PT-120 or TP-120 XGA Line Receiver 1 4 VS Switch Slide down to set the V SYNC to negative polarity (NEGATIVE); slide up2 to set the V SYNC to positive polarity (NORM) 5 HS Switch Slide down to set the H SYNC to negative polarity (NEGATIVE); slide up2 to set the H SYNC to positive polarity (NORM) 6 ON LED Illuminates when receiving power 1 Using a UTP cable with CAT 5 connectors at both ends (the PINOUT is defined in Table 5 and Figure 6) 2 By default, both switches are set down (for a negative V SYNC and H SYNC polarity)

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Your XGA Line Transmitter(s) / Receiver 6 4.2 Your WP-110 XGA Line Transmitter The WP-110 is available in three versions: one for the US, one for Belgium and Germany, and one for the UK and most of Europe1, as Figure 2 and Table 2 define: Figure 2: WP-110 XGA Line Transmitter 1 Excluding Belgium and Germany

Your XGA Line Transmitter(s) / Receiver

7 Table 2: WP-110 XGA Line Transmitter Features # Feature Function 1 XGA IN 15-pin HD (F) Connector Connect to the XGA source 2 ON LED Illuminates when receiving power 3 HS3 Switch Slide the switch to the left1 to change the HS polarity to (NEG.) negative polarity2; slide the switch to the right (NORM.) to retain the polarity 4 VS3 Switch Slide the switch to the left1 to change the VS polarity to (NEG.) negative polarity2; slide the switch to the right (NORM.) to retain the polarity 5 LINE OUT RJ-45 Connector Connects to the LINE IN RJ-45 connector on the PT-120 or TP-120 XGA Line Receiver 4 6 POWER SUPPLY GND PIN Connect (-) to the Ground +12V DC PIN Connect (+) to the connector for powering the unit 4.3 Your PT-120 XGA Line Receiver This section describes the PT-120 XGA Line Receiver. Figure 3 and Table 3 define the topside of the PT-120 XGA Line Receiver: Figure 3: PT-120 XGA Line Receiver 1 By default, both switches are set to the right 2 Downgoing syncs 3 SYNC 4 Using a UTP cable with CAT 5 connectors at both ends (the PINOUT is defined in Table 5 and Figure 6)

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Your XGA Line Transmitter(s) / Receiver 8 Table 3: PT-120 XGA Line Receiver Features # Feature Function 1 12V DC +12V DC connector for powering the unit 2 XGA OUTPUT 15-pin HD (F) Connector Connect to the XGA acceptor 3 ON LED Illuminates when receiving power 4 LEVEL Trimmer Adjusts1 the output signal level 5 EQ.2 Trimmer Adjusts1 the cable compensation equalization level 6 LINE IN RJ-45 Connector Connects to the LINE OUT RJ-45 connector on the PT-110 or WP-110 XGA Line Receiver 3 4.4 Your TP-120 XGA Line Receiver This section describes the TP-120 XGA Line Receiver and its underside. Figure 4 and Table 4 define the topside of the TP-120 XGA Line Receiver: Figure 4: TP-120 XGA Line Receiver Table 4: TP-120 XGA Line Receiver Features # Feature Function 1 12V DC +12V DC connector for powering the unit 2 XGA OUT 15-pin HD (F) Connector Connect to the XGA acceptor 3 LINE IN RJ-45 Connector Connects to the LINE OUT RJ-45 connector on the PT-110 or WP-110 XGA Line Receiver3 4 EQ.2 Trimmer Adjusts1 the cable compensation equalization level 5 LEVEL Trimmer Adjusts1 the output signal level 6 ON LED Illuminates when receiving power 1 Use a screwdriver to carefully rotate the trimmer, adjusting the appropriate level 2 Degradation and VGA/XGA signal loss can result from using long cables (due to stray capacitance), sometimes leading to a total loss of sharpness in high-resolution signals 3 Using a UTP cable with CAT 5 connectors at both ends (the PINOUT is defined in Table 5 and Figure 6)

Using the XGA Line Transmitter(s) / Receiver

9 5 Using the XGA Line Transmitter(s) / Receiver You can use the PT-1101 XGA Line Transmitter and the TP-120 XGA Line Receiver to configure an XGA-to-Twisted Pair Transmitter and Receiver system. To connect the PT-110 XGA Line Transmitter with the TP-120 XGA Line Receiver, as the example in Figure 5 illustrates, do the following: 1. On the PT-110, connect the XGA source (for example, the 15-pin HD output from a computer’s graphics card) to the XGA INPUT 15-pin HD (F) connector. 2. On the TP-120, connect the XGA OUT 15-pin HD (F) connector to the XGA acceptor (for example, a monitor). 3. Connect the LINE OUTPUT RJ-45 connector on the PT-110 to the LINE IN RJ-45 connector on the TP-120, via UTP cabling (with a range of more than 300ft (>100m)). 4. On both2 the PT-110 and the TP-120, connect the 12V DC power adapter to the power socket and connect the adapter to the mains electricity. The signal from the XGA source is transmitted via CAT 5 cable, decoded and converted at the XGA OUT 15-pin HD (F) connector to the XGA acceptor. 5. On the TP-120, adjust3 the output signal level and/or cable compensation equalization level, if required. 6. If necessary, set the H SYNC and V SYNC switches4, on the underside of the PT-110. 1 You can use the WP-110 (not shown in Figure 5) instead of the PT-110. For details, see section 5.1 2 For details of the power connect feature see section 3.5 3 Use a screwdriver to carefully rotate the trimmer, adjusting the appropriate level 4 By default, both switches are set for normal H SYNC and V SYNC polarity

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Using the XGA Line Transmitter(s) / Receiver 10 Figure 5: XGA-to-Twisted Pair Transmitter and Receiver System via UTP Cable

Using the XGA Line Transmitter(s) / Receiver

11 5.1 Installing the WP-110 XGA Line Transmitter To install your WP-110 XGA Line Transmitter: 1. Connect the LINE OUT RJ-45 connector to the pre-installed UTP wiring in the wall box opening that connects via UTP cabling to the LINE IN RJ-45 connector of the PT-120 or TP-120. 2. Connect your 12V DC power supply to the POWER SUPPLY pins1, taking care that polarity is correct. 3. Insert the WP-110 directly into the wall box opening, and then mount the front panel securely using the screws. 4. Connect the XGA source to the XGA IN 15-pin HD (F) connector. 5.2 Wiring the CAT 5 LINE IN / LINE OUT RJ-45 Connectors Table 5 and Figure 6 define the CAT 5 PINOUT, using a straight pin-to-pin cable with RJ-45 connectors: Table 5: CAT 5 PINOUT Figure 6: CAT 5 PINOUT EIA /TIA 568A EIA /TIA 568B PIN Wire Color PIN Wire Color 1 Green / White 1 Orange / White 2 Green 2 Orange 3 Orange / White 3 Green / White 4 Blue 4 Blue 5 Blue / White 5 Blue / White 6 Orange 6 Green 7 Brown / White 7 Brown / White 8 Brown 8 Brown Pair 1 4 and 5 Pair 1 4 and 5 Pair 2 3 and 6 Pair 2 1 and 2 Pair 3 1 and 2 Pair 3 3 and 6 Pair 4 7 and 8 Pair 4 7 and 8 1 Connect the wire labeled “+” to the +12V pin, and the wire labeled “–” to the GND pin

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Technical Specifications 12 6 Technical Specifications Table 6 lists the technical specifications: Table 6: Technical Specifications1 of the PT-110 / WP-110 / PT-120 / TP-120 PT-110 WP-110 PT-120 TP-120 INPUTS: 1 VGA / UXGA on a 15-pin HD connector 1 VGA / UXGA on a 15-pin HD connector 1 RJ-45 LINE IN connector 1 RJ-45 LINE IN connector OUTPUTS: 1 RJ-45 LINE OUTPUT connector 1 RJ-45 LINE OUT connector 1 VGA / UXGA on a 15-pin HD connector 1 VGA / UXGA on a 15-pin HD connector MAX. OUTPUT LEVEL: 1.5Vpp 1.4Vpp RESOLUTION: Up to UXGA DIFF. GAIN2: 2.9% (worst case) DIFF. PHASE2 0.3 Deg (worst case) K-FACTOR2: <0.05% S/N RATIO2: 69dB (worst case) CONTROLS: –7.7dB to +3.1dB, 130m level, 0dB to +25dB EQ. @ 50MHz –7.5dB to +4.4dB, 130m level, 0dB to +33dBm 130m, EQ. @ 50MHz COUPLING: AC AC DC AC POWER SOURCE: 12V DC 60mA 12V DC 60mA 12V DC 175mA 12V DC 160mA DIMENSIONS: 6cm x 6.5cm x 2.5cm (2.36" x 2.56" x 1") W, D, H USA: 6.9cm x 3.8cm x 11.4cm (2.72" x 1.5" x 4.5") W, D, H 6cm x 6.5cm x 2.5cm (2.36" x 2.56" x 1") W, D, H 12cm x 7.5cm x 2.5cm (4.7" x 0.98" x 2.95") W, D, H Belgium and Germany: 8cm x 3.8cm x 8cm (3.15" x 1.5" x 3.15") W, D, H UK and most of Europe3: 8.6cm x 3.8cm x 8.6cm (3.39" x 1.5" x 3.39") W, D, H WEIGHT: 0.14kg (0.31lbs) approx. 0.14kg (0.31lbs) approx. 0.14kg (0.31lbs) approx. 0.3kg (0.66lbs) approx. ACCESSORIES: Power supply OPTIONS: 19-inch rack adapters 1 Specifications are subject to change without notice 2 For the transmitter/receiver pair 3 Excluding Belgium and Germany

WHO IS PROTECTED?

WHAT IS COVERED AND WHAT IS NOT COVERED WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR HOW YOU CAN GET WARRANTY SERVICE LIMITATION OF IMPLIED WARRANTIES EXCLUSION OF DAMAGES CAUTION! We warrant this product free from defects in material and workmanship under the following terms. HOW LONG IS THE WARRANTY Labor and parts are warranted for seven years from the date of the first customer purchase. Only the first purchase customer may enforce this warranty. We will pay labor and material expenses for covered items. We will not pay for the following: The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option. Kramer shall not be liable for: This warranty gives you specific legal rights, and you may also have other rights, which vary from place to place. All products returned to Kramer for service must have prior approval. This may be obtained from your dealer. This equipment has been tested to determine compliance with the requirements of: EN-50081: "Electromagnetic compatibility (EMC); generic emission standard. Residential, commercial and light industry" EN-50082: "Electromagnetic compatibility (EMC) generic immunity standard. Part 1: Residential, commercial and light industry environment". CFR-47: FCC* Rules and Regulations: Part 15: “Radio frequency devices Subpart B Unintentional radiators” Except as below, this warranty covers all defects in material or workmanship in this product. The following are not covered by the warranty: 1. Any product which is not distributed by us or which is not purchased from an authorized Kramer dealer. If you are uncertain as to whether a dealer is authorized, please contact Kramer at one of the agents listed in the Web site www.kramerelectronics.com. 2. Any product, on which the serial number has been defaced, modified or removed, or on which the WARRANTY VOID TAMPERED sticker has been torn, 3. Damage, deterioration or malfunction resulting from: i) Accident, misuse, abuse, neglect, fire, water, lightning or other acts of nature ii) Product modification, or failure to follow instructions supplied with the product iii) Repair or attempted repair by anyone not authorized by Kramer iv) Any shipment of the product (claims must be presented to the carrier) v) Removal or installation of the product vi) Any other cause, which does not relate to a product defect vii) Cartons, equipment enclosures, cables or accessories used in conjunction with the product 1. Removal or installations charges. 2. Costs of initial technical adjustments (set-up), including adjustment of user controls or programming. These costs are the responsibility of the Kramer dealer from whom the product was purchased. 3. Shipping charges. 1. To obtain service on you product, you must take or ship it prepaid to any authorized Kramer service center. 2. Whenever warranty service is required, the original dated invoice (or a copy) must be presented as proof of warranty coverage, and should be included in any shipment of the product. Please also include in any mailing a contact name, company, address, and a description of the problem(s). 3. For the name of the nearest Kramer authorized service center, consult your authorized dealer. All implied warranties, including warranties of merchantability and fitness for a particular purpose, are limited in duration to the length of this warranty. 1. Damage to other property caused by defects in this product, damages based upon inconvenience, loss of use of the product, loss of time, commercial loss; or: 2. Any other damages, whether incidental, consequential or otherwise. Some countries may not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations and exclusions may not apply to you. Servicing the machines can only be done by an authorized Kramer technician. Any user who makes changes or modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the equipment. Please use recommended interconnection cables to connect the machine to other components. IF reattached, removed or otherwise interfered with. * FCC and CE approved using STP cable (for twisted pair products) NOTE: Part 1:

Kramer Electronics, Ltd.

Web site: www.kramerelectronics.com E-mail: [email protected] P/N: 2900-000085 REV 10 For the latest information on our products and a list of Kramer distributors, visit our Web site: www.kramerelectronics.com where updates to this user manual may be found. We welcome your questions, comments and feedback. Caution Safety Warning: Disconnect the unit from the power supply before opening/servicing.