Leviton 47609-EPM Instructions For Use
Read Online
Read the Leviton 47609-EPM Instructions For Use online using the built-in PDF viewer.
Text of the manual
Telephone Patching Expansion
Board
DESCRIPTION
The Telephone Patching Expansion Board is
designed to fit easily into Leviton’s Pre-Configured
Structured Cabling Panels. Working in conjunction
with the Category 5e Voice and Data Module, the
Telephone Distribution Module,
and other
Structured Media™ Modules, this product expands
the four-line T568A telephone distribution system
to seven additional locations. Consists of one 110
D4 connector bridged to seven 8P8C connectors
and mounted on a printed circuit board. (Figure 1)
Incoming telephone service is terminated on the
110 connector, or by patch cord to one of the seven
8P8C connectors.
INSTALLATION
To a Pre-Configured Structured Cabling Panel
Structured Cabling Panel without Clips
1. Align board with appropriate, empty, Pre-
Configured Structured Cabling Panel opening
(cutout). Ensure the screw holes on the Panel
opening match the screw holes on the
Expansion Board.
2. Using the provided screws,
secure the
Expansion Board to the Panel at alternate
corners.
Structured Cabling Panel with Clips
1. Align Expansion Board with appropriate, empty,
Pre-Configured Structured Cabling Panel
opening (cutout).
2. Insert bottom of Expansion Board into slot and
push the top into the clips. The clips will click
and secure the Board into place.
Instructions for Use
Directives d’utilisation
Instrucciones de uso
Telephone Patching
Expansion Board
Carte d’extension
téléphonique
Tarjeta de Expansión
Telefónica
47609-EPM
1
Tarjeta de Expansión Telefónica
DESCRIPTION
La Tarjeta de Expansión Telefónica está diseñada
para encajar en los paneles de cableado
estructurado de Leviton. Funciona en conjunción
con el Módulo de Voz y Datos Categoría 5e, el
Módulo de Distribución Telefónica, u otros Módulos
de Structured Media. Este producto expande el
sistema de distribución telefónica de 4 líneas
T568A a 7 localidades adicionales. Consiste de un
conector 110 D4 conectado a siete conectores
8P8C e instalado en una tarjeta de circuito impreso
(Ilustración 1). El servicio telefónico se conecta a
un conector 110 o por cable de interconexión a uno
de los siete conectores 8P8C.
INSTALACIÓN
A un Panel de Cableado Estructurado
Configurado
Panel de Cableado sin Ganchos
1. Alinee la tarjeta con la apertura de un Panel de
Cableado Estructurado Configurado vacío.
Asegúrese que los agujeros de los tornillos del
Panel estén alineados con los agujeros de los
tornillos de la Tarjeta de Expansión.
2. Fije la Tarjeta de Expansión a esquinas
alternadas del Panel, utilizando los tornillos
incluidos.
Panel de Cableado Estructurado con Ganchos
1. Alinee la tarjeta con la apertura de un Panel de
Cableado Estructurado Configurado vacío.
2. Inserte la parte inferior de la Tarjeta de
Expansión en al ranura y presione la parte
superior en los ganchos (escuchará un “clic”).
Estos fijarán la tarjeta en su lugar.
Carte d’extension téléphonique
DESCRIPTION
Cette carte d’extension est conçue pour s’adapter
aisément aux panneaux de câblage structuré
préconfigurés de Leviton. Alliée à un module de
transmission de la voix/de données de catégorie
5e, à un module de distribution téléphonique ou à
d’autres éléments Structured MediaMC, elle
permet d’étendre un système à quatre lignes à
sept emplacements supplémentaires. La carte
consiste en un connecteur 110 D4 relié à sept
autres de type 8P8C sur une plaquette de circuits
imprimés (figure 1). Il suffit de raccorder le service
entrant au connecteur 110 ou, par le biais de
cordons de connexion, à l’un ou à l’autre des sept
entrées 8P8C.
INSTALLATION
Dans un panneau de câblage structuré
préconfiguré
Panneau sans agrafes
1. Insérer la carte dans une des ouvertures
(débouchures) vides du panneau convenant à
cet usage, en s’assurant que les trous de vis
soient bien alignés.
2. Fixer la carte au panneau en serrant les vis
fournies à des coins opposés.
Panneau avec agrafes
1. Insérer la carte dans une des ouvertures
(débouchures) vides du panneau convenant à
cet usage.
2. Insérer le bas de la carte dans la fente, puis
appuyer sur le haut pour qu’il s’enclenche dans
les agrafes; celles-ci devraient émettre un
déclic quand la carte est bien installée.
A Division of Leviton Manufacturing Co.,Inc.
Phone: (425) 485-4288
Fax: (425) 483-5270
www.levitonvoicedata.com
2222 - 222nd Street SE
Bothell, WA 98021, USA
Phone: (425) 485-4288
Fax: (425) 483-5270
110 Wiring Termination
Wire the 110 D4 connector according to T568A
standards. (Figure 2)
1= White/Blue
Blue/White
2= White/Orange
Orange/White
3= White/Green
Green/White
4= White/Brown
Brown/White
To view pictures, descriptions, specifications, or
instruction sheets for the parts described in this
instruction sheet, please visit our web site at:
www.levitonvoicedata.com.
Terminación Tipo 110
Conecte los conectores 110 D4 de acuerdo a los
estándares T568A (Ilustración 2).
1= Blanco/Azul
Azul/Blanco
2= Blanco/Naranja
Naranja/Blanco
3= Blanco/Verde
Verde/Blanco
4= Blanco/Marrón
Marrón/Blanco
Para observar ilustraciones, descripciones, especifi-
caciones, o instrucciones para las partes descriptas
en
este
documento,
favor
de
visitar
www.levitonvoicedata.com.
Terminaisons de type 110
Effectuer le câblage du connecteur 110 D4 suivant
les normes T568A (figure 2).
1= Blanc/Bleu
Bleu/Blanc
2= Blanc/Orange
Orange/Blanc
3= Blanc/Vert
Vert/Blanc
4= Blanc/Brun
Brun/Blanc
Pour voir les images, descriptions, caractéristiques
techniques et directives relatives aux dispositifs
décrits aux présentes, on peut visiter le site Web
www.levitonvoicedata.com.
DI-100-47609-20A
IMPORTANT INSTRUCTIONS
1. Read and understand all instructions. Follow all warnings
and instructions marked on the product.
2. Do not use this product near water—e.g., near a tub,
wash basin, kitchen sink or laundry tub, in a wet base-
ment, or near a swimming pool.
3. Never push objects of any kind into this product through
openings, as they may touch dangerous voltages.
4. SAVE THESE INSTRUCTIONS.
SAFETY INFORMATION
1. Never install communications wiring or components dur-
ing a lightning storm.
2. Never install communications components in wet loca-
tions unless the components are designed specifically for
use in wet locations.
3. Never touch uninsulated wires or terminals unless the
wiring has been disconnected at the network interface.
4. Use caution when installing or modifying communications
wiring or components.
5. To prevent electrical shock, each opening must be filled with a
module.
DIRECTIVES IMPORTANTES
1.
Lire les présentes directives et s’assurer de bien les comprendre;
observer tous les avertissements et directives apparaissant sur le
dispositif.
2.
Ne pas installer ce dispositif à proximité d’une source d’eau –
comme une baignoire, un bac à laver, une cuve à lessive ou un
évier de cuisine –, dans un sous-sol humide ni près d’une piscine.
3.
Ne jamais insérer quelque objet que ce soit dans les ouvertures
de ce dispositif; il pourrait entrer en contact avec des tensions
dangereuses.
4.
CONSERVER LES PRÉSENTES DIRECTIVES.
CONSIGNES DE SÉCURITÉ
1.
Ne jamais effectuer l’installation de câblage ou de composants de
communication pendant un orage.
2.
Ne jamais installer de composants de communication dans des
endroits mouillés à moins qu’il s’agisse de dispositifs conçus spé-
cialement pour cet usage.
3.
Ne jamais toucher des bornes de raccordement ni du fil non
isolés, à moins que le circuit ne soit pas relié à l’interface réseau.
4.
On doit prendre toutes les précautions requises lorsqu’on installe
ou modifie du câblage ou des composants de télécommunication.
5.
Afin d’éviter les chocs électriques, toutes les ouvertures doivent être
dotées d’un module.
INSTRUCCIONES IMPORTANTES
1. Lea y comprenda perfectamente todas las instrucciones. Siga
todas las instrucciones y advertencias marcadas sobre el pro-
ducto.
2. No utilice estos productos cerca del agua, por ejemplo, cerca de
bañeras, tinas, lavaderos o lavabos, fregaderos de cocina, tinas
para lavandería, dentro de sótanos húmedos, o cerca de pisci-
nas.
3. Nunca introduzca objetos de ningún tipo a través de las aber-
turas de estos productos,
ya que pueden hacer contacto con voltajes peligrosos.
4. CONSERVE ESTAS INSTRUCCIONES.
INFORMACIÓN SOBRE SEGURIDAD
1.
Nunca instale cableado o componentes de comunicaciones
durante una tormenta eléctrica.
2.
Nunca instale componentes de comunicaciones en un local
mojado, a menos que los componentes hayan sido diseñados
especificamente para uso en locales mojados.
3.
Nunca toque alambres o terminales sin su cubierta, a menos
que el cableado haya sido desconectado en el interfaz de la
red.
4.
Use precaución cuando esté instalando o modificando cableado
o componentes de comunicaciones.
5.
Para impedir choques eléctricos, se debe cubrir cada abertura
con un módulo.
2