LG LS-C1863R Manual
Read Online
Read the LG LS-C1863R Manual online using the built-in PDF viewer.
Text of the manual
Room Air Conditioner
SVC MANUAL(Exploded View)
MODEL :
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
Internal Use Only
http://biz.lgservice.com
LS-C1863R/W/B/D/M/CM0
LS-H1863R/W/B/D/M/CM0
LS-C2463R/W/B/D/M/CM0
LS-H2463R/W/B/D/M/CM0
LS-C1823R/W/B/D/M/CM0
LS-C1823R/W/B/D/M/CM2
LS-H1823R/W/B/D/M/CM0
LS-C2423R/W/B/D/M/CM0
LS-H2423R/W/B/D/M/CM0
AS-H2463R/D/M/WM1
AS-H1863B/M/R/WM0
AS-H2463R/D/M/WM1
LS-C2463B/C/D/M/RM1
LS-C1823RM1
LS-H1863B/D/M/R/WM1
AS-H1863*M3
AS-H2463*M3
LS-H1863*M3
LS-C2463*M3
LS-H2463*M3
LS-C1863*M3
LS-C2463*M4
- 2 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Air Conditioner Service Manual
TABLE OF CONTENTS
LG Model Name...............................................................................................................................................3
Safety Precautions..........................................................................................................................................4
Dimensions......................................................................................................................................................8
Symbols used in this Manual......................................................................................................................8
Indoor Unit.................................................................................................................................................8
Outdoor Unit...............................................................................................................................................9
Installation .....................................................................................................................................................12
Select the best Location ..........................................................................................................................12
Piping Length and Elevation.....................................................................................................................13
Fixing Installation Plate ............................................................................................................................14
Drill a Hole in the Wall..............................................................................................................................14
Flaring Work.............................................................................................................................................15
Connecting the Piping..............................................................................................................................16
Connecting the Cables to the Indoor Unit ................................................................................................22
Connecting the Cables to the Outdoor Unit..............................................................................................23
Checking the Drainage.............................................................................................................................23
Forming the Piping ...................................................................................................................................24
Air Purging ...............................................................................................................................................25
Air Purging with Vacuum Pump................................................................................................................25
Test Running ............................................................................................................................................27
Operation .......................................................................................................................................................28
Function of Controls .................................................................................................................................28
Display Function ......................................................................................................................................35
Self-diagnosis Function............................................................................................................................36
Remote Control Operations......................................................................................................................37
Disassembly ..................................................................................................................................................38
Indoor Unit................................................................................................................................................38
Troubleshooting Guide.................................................................................................................................41
Refrigeration Cycle Diagram ....................................................................................................................41
2-way, 3-way Valve .................................................................................................................................42
Cycle Parts...............................................................................................................................................47
Electronic Parts ........................................................................................................................................48
Schematic Diagram.......................................................................................................................................55
Electric Control Device.............................................................................................................................55
Wiring Diagram.........................................................................................................................................56
Components Location ..............................................................................................................................58
Product Specifications .................................................................................................................................60
Exploded View...............................................................................................................................................62
- 3 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
LG Model Name
LG Model Name
1
2
-
3
4
5
6
7
8
9
10
Code
Type
Code of Model
Meaning
1
Producing Center,
A~Z
L: Chang-won R22
N: India
Refrigerant
A: Chang-won R410A
Z: Brazil
C: Chang-won R407C
D: Indonesia
T: China
X: Mexico
K: Turkey R22
V: Vietnam
U: China R410A
E: Turkey R410A
S: Out Sourcing
H: Thailand
2
Product Type
A~Z
S: Split Type Air Conditioner
3
Cooling/Heating/Inverter
A~Z
C: Cooling only
H: Heat pump
X: C/O + E/Heater
Z: H/P + E/Heater
V: AC Inverter C/O
N: AC Inverter H/P
Q: DC Inverter C/O
W: DC Inverter H/P
4, 5
Capacity
0~9
Cooling/Heating Capacity
Ex. "09" ¡ 9,000 Btu/h
6
Electric Range
1~9
1: 115V/60Hz,
A: 220V, 50Hz, 3Phase
A~Z
2: 220V/60Hz
B: 208~230V, 60Hz, 3Phase
3: 208-230V/60Hz
C: 575V, 50Hz, 3Phase
5: 200-220V/50Hz
D: 440~460, 60Hz, 3Phase
6: 220-240V/50Hz
E: 265V, 60Hz
7: 110V, 50/60Hz
F: 200V, 50/60Hz
8: 380-415V/50Hz
9: 380-415V/60Hz
7
Chassis
1~9
Name of Chassis of Unit
Ex. 3 ¡ S3 Chassis
8
Look
A~Z
Look,
Color (Artcool Model)
9
Function
A~Z
10
Serial No.
1~9
LG Model De
* ARTCOOL COLOR
velopment Serial No.
Basic
A
Basic+4Way
B
Plasma Filter
C
Plasma Filter+4 Way
D
Tele+LCD
E
Tele+LCD+Nano plasma+4Way
F
Nano Plasma F+(A/changeover)+A/clean+Low A
G
Nano Plasma F+(A/changeover)+A/clean+4way+Low A
H
Tele+LED+4way
I
Internet
J
Plasma F+4Way+Oxy generator
K
Nano Plasma F+(A/changeover)+A/clean
L
Nano Plasma F+(A/changeover)+A/clean+4way
M
Nano Plasma F+(A/changeover)+A/clean+PTC
N
Nano Plasma F+(A/changeover)+Autoclean+4way+PTC
P
Nano Plasma F+(A/changeover)+A/clean+4way+Low A+PTC
Q
Negative ION+A/Clean
R
(Nano)Plasma+Negative ION+A/Clean
S
4way+(Nano)Plasma F+Negative ION+Healthy dehumidification+A/Clean
T
Nano Plasma F+4Way+(A/changeover)+A/clean+Oxy generator
U
4way+(Nano)Plasma F+Negative ION+Healthy dehumidification+A/Clean+Oxy generator
V
Dry Contact
W
Wired Remocon
8
R
Mirror
W
White Wood
B
Blue
D
Wood
M
Metal
C
Cherry
N
Walnut
A
Gogh
S
Sisley
Q
Quran
K
Mecca
2004
- 4 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must
be followed.
I Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
I Meanings of symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Be sure not to do.
Be sure to follow the instruction.
Always perform grounding.
Don’t use a power cord, a plug
or a loose socket which is
damaged.
For installation of the product,
always contact the service center or
a professional installation agency.
• Otherwise, it may cause electrical
shock.
• Otherwise, it may cause a fire or
electrical shock.
• Otherwise, it may cause a fire, elec-
trical shock, explosion or injury.
Securely attach the electrical
part cover to the indoor unit
and the service panel to the
outdoor unit.
Always install an air leakage
breaker and a dedicated
switching board.
Do not keep or use flammable
gases or combustibles near
the air conditioner.
• If the electrical part cover of the
indoor unit and the service panel of
the outdoor unit are not attached
securely, it could result in a fire or
electric shock due to dust, water, etc.
• No installation may cause a fire and
electrical shock.
• Otherwise, it may cause a fire or the
failure of product.
I Installation
Wax
Thinner
- 5 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Safety Precautions
I Operation
Do not modify or extend the
power cord randomly.
Take care so that the power
cord may not be pulled during
operation.
Unplug the unit if strange
sounds, smell, or smoke
comes from it.
• Otherwise, it may cause a fire or
electrical shock.
• Otherwise, it may cause a fire or
electrical shock.
• Otherwise, it may cause electrical
shock or a fire.
• Sharp edges may cause injury.
• It will cause an electric shock or a
fire due to heat generation.
• Otherwise, it may cause a fire or
electrical shock.
Use caution when unpacking
and installing.
Do not share the outlet with
other appliances.
Do not use the damaged
power cord.
Ensure that an installation
frame of the outdoor unit is
not damaged due to use for a
long time.
Do not disassemble or repair
the product randomly.
Do not install the product at a
place that ther is concern of
falling down.
• It may cause injury or an accident.
• It will cause a fire or electrical shock.
• Otherwise, it may result in personal
injury.
- 6 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Safety Precautions
Keep the flames away.
Take the power plug out if neces-
sary, holding the head of the plug
and do not touch it with wet hands.
Do not use the power cord
near the heating tools.
• Otherwise, it may cause a fire.
• Otherwise, it may cause a fire or
electrical shock.
• Otherwise, it may cause a fire and
electrical shock.
Do not open the suction inlet
of the indoor/outdoor unit dur-
ing operation.
Do not allow water to run into
electrical parts.
Never touch the metal parts of
the unit when removing the fil-
ter.
• Otherwise, it may electrical shock
and failure.
• Otherwise, it may cause the failure of
machine or electrical shock.
• They are sharp and may cause
injury.
Do not step on the indoor/outdoor unit and do
not put anything on it.
Do not place a heavy object on the power cord.
• It may cause an injury through dropping of the unit or
falling down.
• Otherwise, it may cause a fire or electrical shock.
When the product is submerged into water,
always contact the service center.
Take care so that children may not step on the
outdoor unit.
• Otherwise, it may cause a fire or electrical shock.
• Otherwise, children may be seriously injured due to
falling down.
- 7 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Safety Precautions
I Installation
Install the drain hose to
ensure that drain can be
securely done.
Install the product so that the
noise or hot wind from the
outdoor unit may not cause
any damage to the neighbors.
Always inspect gas leakage
after the installation and repair
of product.
• Otherwise, it may cause water leak-
age.
• Otherwise, it may cause dispute with
the neighbors.
• Otherwise, it may cause the failure of
product.
Wax
Thinner
Keep level parallel in installing the product.
Avoid excessive cooling and perform ventila-
tion sometimes.
• Otherwise, it may cause vibration or water leakage.
• Otherwise, it may do harm to your health.
Use a soft cloth to clean. Do not use wax, thin-
ner, or a strong detergent.
When gas leaks, open the window for ventila-
tion before operating the unit.
• The appearance of the air conditioner may deteriorate,
change color, or develop surface flaws.
• Otherwise, it may cause explosion, and a fire.
I Operation
- 8 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Dimensions
Dimensions
Installation plate
D
H
W
W
mm
1170
H
mm
315
D
mm
173
Model
Dimension
INDOOR UNIT
Indoor Unit
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to the
air conditioner.
This symbol indicates special notes.
NOTICE
Symbols used in this Manual
- 9 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
W
mm
870
870
H
mm
655
800
D
mm
320
320
L1
mm
370
370
L2
mm
340
340
L3
mm
25
25
L4
mm
630
775
L5
mm
25
25
L6
mm
546
546
L7
mm
162
162
L8
mm
162
162
L9
mm
54
54
L10
mm
74.5
74.5
L11
mm
79
79
LS-C1863R/W/B/D/M/CM0, LS-H1863R/W/B/D/M/CM0
LS-C2463R/W/B/D/M/CM0, LS-H2463R/W/B/D/M/CM0
LS-H2423R/W/B/D/M/CM0, AS-H1863B/M/R/WM0
AS-H2463B/M/R/WM0, LS-C2463B/C/D/M/RM1
LS-C1823RM1, LS-H1863B/D/M/R/WM1
LS-H1863*M3, LS-C2463*M3, LS-H2463*M3
LS-C1863*M3, LS-C2463*M4
AS-H2463R/D/M/WM1
Outdoor Unit
Dimensions
W
L7
L6
L8
L9
D
L1
L2
L3
L10
L11
L4
L5
H
Gas side
Liquid side
MODEL
DIM
- 10 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Dimensions
W
L2
L3
L1
D
H
L4
L5
Gas side
(3-way valve)
Liquid side
(2-way valve)
MODEL
DIM
unit
W
mm
840
H
mm
577
D
mm
276
L1
mm
287
L2
mm
64
L3
mm
518
L4
mm
10
L5
mm
100
LS-C1823R/W/B/D/M/CM2, AS-H1863*M3
LS-C2423R/W/B/D/M/CM0, AS-H2463*M3
- 11 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Dimensions
W
D
L1
L2
H
L3
L4
L5
L6
L7
L8
L9
L10
Liquid side
2-way valve
Gas side
3-way valve
MODEL
DIM
unit
W
mm
801
H
mm
555
D
mm
262
L1
mm
339
L2
mm
37
L3
mm
543.6
L4
mm
11.4
L5
mm
591
L6
mm
105
L7
mm
105
L8
mm
72.5
L9
mm
86.4
L10
mm
77
LS-C1823R/W/B/D/M/CM0
LS-H1823R/W/B/D/M/CM0
- 12 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
Installation
Indoor unit
1. Do not have any heat or steam near the unit.
2. Select a place where there are no obstacles in front
of the unit.
3. Make sure that condensation drainage can be conve-
niently routed away.
4. Do not install near a doorway.
5. Ensure that the interval between a wall and the left
(or right) of the unit is more than 50cm. The unit
should be installed as high as possible on the wall,
allowing a minimum of 10cm from ceiling.
6. Use a stud finder to locate studs to prevent unneces-
sary damage to the wall.
Outdoor unit
1. If an awning is built over the unit to prevent direct
sunlight or rain exposure, make sure that heat radia-
tion from the condenser is not restricted.
2. Ensure that the space around the back and sides is
more than 10cm. The front of the unit should have
more than 70cm of space.
3. Do not place animals and plants in the path of the
warm air.
4. Take the weight of the air conditioner into account
and select a place where noise and vibration are min-
imum.
5. Select a place where the warm air and noise from the
air conditioner do not disturb neighbors.
Select the best Location
More than 10cm
More than
5cm
More than 2.3m
More than
5cm
CAUTION: Install the indoor unit on the wall where the height from the
floor is more than 2 meters.
More than 10cm
More than 10cm
More
than 60cm
More than 60cm
More than 70cm
- 13 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
Piping Length and Elevation
Outdoor unit
Indoor unit
A
B
Outdoor unit
Indoor unit
A
B
A
Oil trap
Outdoor unit
Indoor unit
B
If piping length is more than 5m
CAUTION: Capacity is based on standard length and maximum allowance length is
on the basis of reliability.
Oil trap should be installed every 5~7 meters.
Pipe Size
Capacity
(Btu/h)
GAS
LIQUID
Max.
Length
A (m)
Additional
Refrigerant
(g/m)
Max.
Elevation
B (m)
Standard
Length
(m)
5k~14k
3/8"(Ø9.52)
1/4"(Ø6.35)
4 or 7.5
20
1/2"(Ø12.7)
1/4"(Ø6.35)
4 or 7.5
20
20
1/2"(Ø12.7)
1/4"(Ø6.35)
4 or 7.5
18k~28k
5/8"(Ø15.88)
1/4"(Ø6.35)
4 or 7.5
5/8"(Ø15.88)
3/8"(Ø9.52)
4 or 7.5
30k~38k
5/8"(Ø15.88)
3/8"(Ø9.52)
7.5
3/4"(Ø19.05)
3/8"(Ø9.52)
7.5
50
30
30
20
15
30
15
30
30
30
30
7
15
7
15
15
15
15
- 14 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a con-
crete wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
2. Measure the wall and mark the centerline. It is
also important to use caution concerning the
location of the installation plate-routing of the
wiring to power outlets is through the walls typi-
cally. Drilling the hole through the wall for piping
connections must be done safely.
Fixing Installation Plate
Installation Plate
Type "A" screw
Installation plate
Ø70mm
Left rear piping
Right rear piping
C
D
B
A
Ø70mm
Left rear piping
Right rear piping
B
A
D
C
Right rear piping
B
A
D
C
Installation plate
(SU)
(SZ)
(S3)
Installation plate
• Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left
with the hole slightly slanted to the outdoor side.
Drill a Hole in the Wall
5-7mm
(3/16"~5/16")
Indoor
WALL
Outdoor
A
B
C
D
SZ
35
33
156
33
(7k~9k)
SU
92
44
67
44
(11k~14k)
S3
58
3
292
3
(18k~26k)
CHASSIS
(Grade)
Distance (mm)
• For S3 chassis, the center of the unit is different
from that of the Installation plate.
- 15 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
Flaring Work
Main cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the following procedure.
Cut the pipes and the cable.
1. Use the piping kit accessory or the pipes purchased
locally.
2. Measure the distance between the indoor and the
outdoor unit.
3. Cut the pipes a little longer than measured distance.
4. Cut the cable 1.5m longer than the pipe length.
Burrs removal
1. Completely remove all burrs from the cut cross sec-
tion of pipe/tube.
2. Put the end of the copper tube/pipe in a downward
direction as you remove burrs in order to avoid drop-
ping burrs into the tubing.
Putting nut on
• Remove flare nuts attached to indoor and outdoor unit,
then put them on pipe/tube having completed burr
removal.
(not possible to put them on after flaring work)
Flaring work
1. Firmly hold copper pipe in a die in the dimension
shown in the table below.
2. Carry out flaring work with the flaring tool.
Copper
pipe
90°
Slanted Uneven Rough
Pipe
Reamer
Point down
Flare nut
Copper tube
mm
inch
mm
Ø6.35
1/4
0~0.5
Ø9.52
3/8
0~0.5
Ø12.7
1/2
0~0.5
Ø15.88
5/8
0~1.0
Ø19.05
3/4
1.0~1.3
Outside diameter
A
Bar
Copper pipe
Clamp handle
Red arrow mark
Cone
Yoke
Handle
Bar
"A"
- 16 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
Check
1. Compare the flared work with the figure by.
2. If a flared section is defective, cut it off and do flar-
ing work again.
Indoor
1. Prepare the indoor unit's piping and drain hose for installation through the wall.
2. Remove the plastic tubing retainer(see the illustra-
tion by) and pull the tubing and drain hose away
from chassis.
3. Replace only the plastic tubing holder 1, not the
holder 2 in the original position.
1. Route the indoor tubing and the drain hose in the
direction of rear right.
2. Insert the connecting cable into the indoor unit from
the outdoor unit through the piping hole.
• Do not connect the cable to the indoor unit.
• Make a small loop with the cable for easy connec-
tion later.
3. Tape the tubing, drain hose, and the connecting
cable. Be sure that the drain hose is located at the
lowest side of the bundle. Locating at the uper side
can cause drain pan to overflow inside the unit.
CAUTION: If the drain hose is routed inside
the room, insulate the hose with an insula-
tion material* so that dripping from "sweat-
ing"(condensation) will not damage furniture
or floors.
*Foamed polyethylene or equivalent is rec-
ommended.
Inclined
Inside is shiny without scratches
Smooth all round
Even length
all round
Surface
damaged
Cracked Uneven
thickness
= Improper flaring =
Connecting the Piping
For right rear piping
Drain hose
Connecting
pipe
Connecting cable
Tape
Drain hose
Tubing holder 1
Tubing holder 2
- 17 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
4. Indoor unit installation
Hook the indoor unit onto the upper portion of the
installation plate.(Engage the two hooks of the rear
top of the indoor unit with the upper edge of the
installation plate.) Ensure that the hooks are prop-
erly seated on the installation plate by moving it left
and right.
Press the lower left and right sides of the unit
against the installation plate until the hooks engage
into their slots(clicking sound).
Connecting the piping to the indoor unit and drain
hose to drain pipe.
1. Align the center of the pipes and sufficiently tighten
the flare nut by hand.
2. Tighten the flare nut with a wrench.
3. When extending the drain hose at the indoor unit,
install the drain pipe.
Wrap the insulation material around the connect-
ing portion.
1. Overlap the connection pipe insulation material and
the indoor unit pipe insulation material. Bind them
together with vinyl tape so that there may be no
gap.
2. Wrap the area which accommodates the rear piping
housing section with vinyl tape.
3. Bundle the piping and drain hose together by wrap-
ping them with vinyl tape for enough to cover where
they fit into the rear piping housing section.
Drain hose
Connecting
cable
Indoor unit tubing
Flare nut
Pipes
Wrench
Indoor unit tubing
Open-end wrench (fixed)
Connection pipe
Flare nut
mm
inch
kg.m
Ø6.35
1/4
1.8
Ø9.52
3/8
4.2
Ø12.7
1/2
5.5
Ø15.88
5/8
6.6
Outside diameter
Torque
Vinyl tape(narrow)
Adhesive
Drain pipe
Indoor unit drain hose
Plastic bands
Insulation material
Vinyl tape(narrow)
Connection pipe
Connecting cable
Vinyl tape (wide)
Wrap with vinyl tape
Indoor unit pipe
Pipe
Wrap with vinyl tape
Drain hose
Pipe
Vinyl tape(wide)
- 18 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
1. Route the indoor tubing and the drain hose to the
required piping hole position.
2. Insert the piping, drain hose, and the connecting
cable into the piping hole.
3. Insert the connecting cable into the indoor unit.
• Don't connect the cable to the indoor unit.
• Make a small loop with the cable for easy connec-
tion later.
4. Tape the drain hose and the connecting cables.
5. Indoor unit installation
• Hang the indoor unit from the hooks at the top of
the installation plate.
• Insert the spacer etc. between the indoor unit and
the installation plate and separate the bottom of
the indoor unit from the wall.
Connecting the piping to the indoor unit and the
drain hose to drain pipe.
1. Align the center of the pipes and sufficiently tighten
the flare nut by hand.
2. Tighten the flare nut with a wrench.
3. When extending the drain hose at the indoor unit,
install the drain pipe.
For left rear piping
Drain pipe
Connecting
cable
1
2
Installation plate
Spacer
Indoor unit
8cm
Indoor unit tubing
Flare nut
Pipes
Wrench
Indoor unit tubing
Connection pipe
Flare nut
Open-end wrench (fixed)
Vinyl tape
Adhesive
Drain hose
Indoor unit drain hose
(narrow)
mm
inch
kg.m
Ø6.35
1/4
1.8
Ø9.52
3/8
4.2
Ø12.7
1/2
5.5
Ø15.88
5/8
6.6
Outside diameter
Torque
- 19 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
Wrap the insulation material around the connect-
ing portion.
1. Overlap the connection pipe heat insulation and the
indoor unit pipe heat insulation material. Bind them
together with vinyl tape so that there may be no
gap.
2. Wrap the area which accommodates the rear piping
housing section with vinyl tape.
3. Bundle the piping and drain hose together by wrap-
ping them with cloth tape over the range within
which they fit into the rear piping housing section.
Reroute the pipings and the drain hose across the
back of the chassis.
Indoor unit installation
1. Remove the spacer.
2. Ensure that the hooks are properly seated on the
installation plate by moving it left and right.
3. Press the lower left and right sides of the unit
against the installation plate until the hooks engage
into their slots(clicking sound).
Plastic bands
Insulation material
Vinyl tape(narrow)
Connection
pipe
Connecting cable
Indoor
unit piping
Pipe
Vinyl tape
(wide)
Wrap with vinyl tape
Drain hose
Vinyl tape(narrow)
Pipe
Wrap with
vinyl tape(wide)
Piping for
passage through
piping hole
Drain hose
Connecting
cable
- 20 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
CAUTION: Installation Information
For left piping. Follow the instruction below.
Good case
• Press on the upper side of clamp and unfold the tubing to downward slowly.
Bad case
• Following bending type from right to left may cause damage to the tubing.
- 21 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
Outdoor
Align the center of the pipings and sufficiently tighten
the flare nut by hand.
Finally, tighten the flare nut with torque wrench until
the wrench clicks.
• When tightening the flare nut with torque wrench,
ensure the direction for tightening follows the arrow
on the wrench.
mm
inch
kg.m
Ø6.35
1/4
1.8
Ø9.52
3/8
4.2
Ø12.7
1/2
5.5
Ø15.88
5/8
6.6
Ø19.05
3/4
6.6
Outside diameter
Torque
Outdoor unit
Liquid side piping
(Smaller diameter)
Gas side
piping
(Bigger
diameter)
Torque wrench
- 22 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
• Connect the cables to the indoor unit by connecting the wires to the terminals on the control board
dividually according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and the
terminal No. are the same as those of the indoor unit.)
• Before connecting the cables to the terminal block, remove the cables in the holder of the control cover and
do it.
Connecting the Cables to the Indoor Unit.
CAUTION:
• The above circuit diagram is subject to change without notice.
• The earth wire should be longer than the common wires.
• When installing, refer to the circuit diagram behind the panel front of the indoor unit.
• Connect the wires firmly so that they may not be pulled out easily.
• Connect the wires according to color codes, referring to the wiring diagram.
CAUTION: If a power plug is not
used, provide a circuit breaker
between power source and the unit
as shown by.
CAUTION: The power cord connected to the "A" unit should be selected according to
the following specifications(Type "B" approved by HAR or SAA).
The power connecting cable connecting the indoor and outdoor unit should be selected
according to the following specifications (Type "B" approved by HAR or SAA).
Air
Conditioner
Main power source
Circuit Breaker
Use a circuit breake
or time delay fuse.
NORMAL
CROSS-SECTIONAL
AREA 0.75mm2
30k, 32k
36k, 38k
0.75
0.75
Cable Type(B)
H07RN-F
H07RN-F
NORMAL CROSS
-SECTIONAL AREA
Grade
(mm2)
(mm2)
(mm2)
5k~9k
12k~14K
0.75
1.0
Unit(A)
Indoor
Indoor
Cable Type(B)
H05VV-F
H05VV-F
NORMAL CROSS
-SECTIONAL AREA
Grade
7k~14k
1.0
Cable Type(B)
H07RN-F
NORMAL CROSS
-SECTIONAL AREA
Grade
- 23 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
1. Remove the control cover from the unit by loos-
ening the screw.
Connect the wires to the terminals on the control
board individually.
2. Secure the cable onto the control board with the
cord clamp.
3. Refix the control cover to the original position
with the screw.
4. Use a recognized circuit breaker "A"
between the power source and the unit.
A disconnecting device to adequately disconnect
all supply lines must be fitted.
Outdoor Unit
Cover control
Cord clamp
1(L) 2(N) 3
4
1(L) 2(N)
3
4
CASE 1
CASE 2
Connecting
cable
CAUTION: After the confirmation of the above conditions, prepare the wiring as
follows:
1) Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring,
be guided by the circuit diagram posted on the inside of control cover.
2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations
to which the unit is subjected during the course of transportation. Check them and make sure that they are
all tightly fastened. (If they are loose, it could cause burn-out of the wires.)
3) Specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the
name plate.
6) Confirm that the cable thickness is as specified in the power source specification.
(Particularly note the relation between cable length and thickness. (Refer to page 24))
7) Always install an earth leakage circuit breaker in a wet or moist area.
8) The following would be caused by voltage drop.
• Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the normal func-
tion of the overload.
9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an air
gap contact separation of at least 3mm in each active(phase) conductors.
7ks~18k
~26k
~30k
~38k
15
20
30
40
Circuit
Breaker
(A)
Grade
Connecting the Cables to the Outdoor Unit
- 24 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
Checking the Drainage
Forming the Piping
1. Checking the drainage.
• Pour a glass of water on the evaporator.
• Ensure the water flows through the drain hose of
the indoor unit without any leakage and goes out
the drain exit.
2. Drain piping
• The drain hose should point downward for easy
drain flow.
• Do not make drain piping like the following.
1. Form the piping by wrapping the connecting
portion of the indoor unit with insulation materi-
al and secure it with two kinds of vinyl tapes.
• If you want to connect an additional drain hose,
the end of the drain outlet should be routed above
the ground. Secure the drain hose appropriately.
2. In cases where the outdoor unit is installed
below the indoor unit perform the following.
• Tape the piping, drain hose and connecting cable
from down to up.
• Secure the tapped piping along the exterior wall
using saddle or equivalent.
3. In cases where the Outdoor unit is installed
above the Indoor unit perform the following.
• Tape the piping and connecting cable from down
to up.
• Secure the taped piping along the exterior wall.
Form a trap to prevent water entering the room.
• Fix the piping onto the wall by saddle or equiva-
lent.
Taping
Drain
hose
Pipings
Connecting
cable
Trap is required to prevent water
from entering into electrical parts.
Seal small openings
around pipings with a
gum type sealer.
Seal a small opening
around the pipings
with gum type sealer.
Trap
Trap
Downward slope
Do not raise
Accumulated
drain water
Tip of drain hose
dipped in water
Air
Waving
Water
leakage
Water
leakage
Ditch
Less than
50mm gap
Water
leakage
Drain pan
Drain
hose
Leakage
checking
Connecting area
drain hose
Leakage
checking
- 25 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
CAUTION: To avoid nitrogen entering the
refrigerant system in a liquid state, the top of
the cylinder must be higher than its bottom when you
pressurize the system. Usually, the cylinder is used
in a vertical standing position.
Air and moisture remaining in the refrigerant system
have undesirable effects as indicated below.
• Pressure in the system rises.
• Operating current rises.
• Cooling(or heating) efficiency drops.
• Moisture in the refrigerant circuit may freeze and
block capillary tubing.
• Water may lead to corrosion of parts in the refrig-
eration system.
Therefore, the refrigerant system must be leak test-
ed and evacuated to remove any noncondensables
and moisture from the system.
1. Preparation
• Check that each tube(both liquid and gas side
tubes) between the indoor and outdoor units have
been properly connected and all wiring for the test
run has been completed. Remove the service
valve caps from both the gas and the liquid side on
the outdoor unit. Note that both the liquid and the
gas side service valves on the outdoor unit are
kept closed at this stage.
2. Leak test
• Connect the manifold valve(with pressure gauges)
and dry nitrogen gas cylinder to this service port
with charge hoses.
• Pressurize the system to no more than 150
P.S.I.G. with dry nitrogen gas and close the cylin-
der valve when the gauge reading reached 150
P.S.I.G. Next, test for leaks with liquid soap.
• Do a leak test of all joints of the tubing(both indoor
and outdoor) and both gas and liquid side service
valves.
Bubbles indicate a leak. Be sure to wipe off the
soap with a clean cloth.
• After the system is found to be free of leaks,
relieve the nitrogen pressure by loosening the
charge hose connector at the nitrogen cylinder.
When the system pressure is reduced to normal,
disconnect the hose from the cylinder.
Lo
Hi
Indoor unit
Outdoor unit
Manifold valve
Charge hose
Nitrogen gas
cylinder(in vertical
standing position)
Pressure
gauge
CAUTION: Be sure to use a manifold valve
for air purging. If it is not available, use a stop
valve for this purpose. The "Hi" knob of the manifold
valve must always be kept close.
Air Purging
Air Purging with Vacuum Pump
- 26 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Installation
3. Evacuation
• Connect the charge hose end described in the pre-
ceding steps to the vacuum pump to evacuate the
tubing and indoor unit.
Confirm the "Lo" knob of the manifold valve is
open. Then, run the vacuum pump.
The operation time for evacuation varies with tub-
ing length and capacity of the pump. The following
table shows the time required for evacuation.
• When the desired vacuum is reached, close the
"Lo" knob of the manifold valve and stop the vacu-
um pump.
4. Finishing the job
• With a service valve wrench, turn the valve stem of
liquid side valve counter-clockwise to fully open
the valve.
• Turn the valve stem of gas side valve counter-
clockwise to fully open the valve.
• Loosen the charge hose connected to the gas side
service port slightly to release the pressure, then
remove the hose.
• Replace the flare nut and its bonnet on the gas
side service port and fasten the flare nut securely
with an adjustable wrench. This process is very
important to prevent leakage from the system.
• Replace the valve caps at both gas and liquid side
service valves and fasten them tight.
This completes air purging with a vacuum pump.
The air conditioner is now ready to test run.
(1) Remove the caps from the 2-way and 3-way
valves.
(2) Remove the service-port cap from the 3-way valve.
(3) To open the 2-way valve turn the valve stem coun-
terclockwise approximately 90°, wait for about 2~3
sec, and close it.
(4) Apply a soap water or a liquid neutral detergent on
the indoor unit connection or outdoor unit connec-
tions by a soft brush to check for leakage of the
connecting points of the piping.
(5) If bubbles come out, the pipes have leakage.
Soap water method
Required time for evacuation when 30 gal/h vacuum pump is
used
10 min. or more
15 min. or more
If tubing length is less than 10m
(33 ft)
if tubing length is longer than 10m
(33 ft)
Gas side
Liquid side
Cap
Hexagonal wrench
3-way valve
(Close)
3-way valve
(Close)
2-way valve
(Open)
2-way valve
(Open)
Indoor unit
Outdoor unit
Lo
Hi
Manifold valve
Vacuum pump
Pressure
gauge
Open
Close
- 27 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Test Running
1. Check that all tubing and wiring have been properly
connected.
2. Check that the gas and liquid side service valves are
fully open.
Prepare remote controller
1. Remove the battery cover
by pulling it according to the
arrow direction.
2. Insert new batteries making
sure that the (+) and (–) of
battery are installed correctly.
3. Reattach the cover by
pushing it back into position.
• Use 2 AAA(1.5volt) batteries. Do not use
rechargeable batteries.
• Remove the batteries from the remote
control if the system is not going to be
used for a long time.
Settlement of outdoor unit
• Anchor the outdoor unit with a bolt and
nut(ø10mm) tightly and horizontally on a concrete
or rigid mount.
• When installing on the wall, roof or rooftop, anchor
the mounting base securely with a nail or wire
assuming the influence of wind and earthquake.
• In the case when the vibration of the unit is con-
veyed to the hose, secure the unit with an anti-
vibration bushing.
Evaluation of the performance
Operate unit for 15~20 minutes, then check the system
refrigerant charge:
1. Measure the pressure of the gas side service valve.
2. Measure the temperature of the intake and discharge
of air.
3. Ensure the difference between the intake tempera-
ture and the discharge is more than 8°C(46°F)
(Cooling) or (Heating).
4. For reference; the gas side pressure of optimum
condition is as below.(Cooling)
If the actual pressure is higher than shown,
the system is most likely over-charged, and
charge should be removed. If the actual pres-
sure are lower than shown, the system is
most likely undercharged, and charge should
be added.
The air conditioner is now ready for use.
NOTICE
NOTICE
Bolt
Tubing connection
Discharge
temperature
Discharge air
Intake temperature
R-22
35°C (95°F)
4~5kg/cm
2G(56.8~71.0 P.S.I.G.)
R-410A
35°C (95°F)
8.5~9.5kg/cm
2G(120~135 P.S.I.G.)
Outside ambient
TEMP.
Refrigerant
The pressure of the gas side
service valve.
This is performed when the unit is to be relocated
or the refrigerant circuit is serviced.
Pump Down means collecting all refrigerant in the
outdoor unit without loss in refrigerant gas.
CAUTION:
Be sure to perform Pump Down procedure with the
unit cooling mode.
Pump Down Procedure
1. Connect a low-pressure gauge manifold hose to
the charge port on the gas side service valve.
2. Open the gas side service valve halfway and purge
the air from the manifold hose using the refrigerant
gas.
3. Close the liquid side service valve(all the way in).
4. Turn on the unit's operating switch and start the
cooling operation.
5. When the low-pressure gauge reading becomes 1
to 0.5kg/cm2 G(14.2 to 7.1 P.S.I.G.), fully close the
gas side valve stem and then quickly turn off the
unit. At that time, Pump Down has been completed
and all refrigerant gas will have been collected in
the outdoor unit.
PUMP DOWN
Installation
- 28 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Operation
DISPLAY
1) C/O Model (high quality LCD remote controller supplied)
Operation Indicator
• On while in appliance operation, off while in appliance pause
Timer Indicator
• On while in timer mode (on/off) and in sleep timer mode, off when timer mode is completed or canceled.
Comp. Running Indicator
• While in appliance operation, on while in outdoor unit compressor running, off while in compressor off
Plasma Indicator
• On while in plasma mode, off while plasma mode is canceled.
Auto restart Indicator
• On while auto restart mode, off while auto restart mode is canceled.
Auto restart
• In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.
If your want to use this operation, press the Auto Restart Button.
Power(Forced Operation)
• Operation starts, when this button is pressed and stops when you press the button again.
2) H/P Model (high quality LCD remote controller supplied)
Operation Indicator
• On while in appliance operation, off while in appliance pause
Timer Indicator
• On while in timer mode (on/off) and in sleep timer mode, off when timer mode is completed or canceled
Defrost Indicator
• Off except when hot start during heating mode operation or while in defrost control.
Plasma Indicator
• On while in plasma mode, off while plasma mode is canceled.
Auto restart Indicator
• On while auto restart mode, off while auto restart mode is canceled.
Auto restart
• In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.
If your want to use this operation, press the Auto Restart Button.
Power(Forced Operation)
• Operation starts, when this button is pressed and stops when you press the button again.
I Cooling Mode Operation
• When the intake air temperature reaches 0.5°C below the setting temp, the compressor and the outdoor fan stop.
• When it reaches 0.5°C above the setting temp, they start to operate again.
Compressor ON Temp=> Setting Temp+0.5°C
Compressor OFF Temp => Setting Temp-0.5°C
• While in compressor running, operating with the airflow speed set by the remote controller. While in compressor
not running, operating with the low airflow speed regardless of the setting.
Function of Controls
Operation
- 29 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
I Healthy Dehumidification Mode
• When the dehumidification operation input by the remote controller is received, the intake air temperature is
detected and the setting temp is automatically set according to the intake air temperature.
26°C ≤ Intake Air Temp => 25°C
24°C ≤ Intake Air Temp < 26°C => Intake Air Temp-1°C
18°C ≤ Intake Air Temp < 24°C => Intake Air Temp-0.5°C
Intake Air Temp < 18°C => 18°C
• While in compressor off, the indoor fan repeats low airflow speed and pause.
• While the intake air temp is between compressor on temp. and compressor off temp., 10-min dehumidification
operation and 4-min compressor off repeat
Compressor ON Temp. => Setting Temp+0.5°C
Compressor OFF Temp. => Setting Temp-0.5°C
• In 10-min dehumidification operation, the indoor fan operates with the low airflow speed.
I Heating Mode Operation
• When the intake air temp reaches +3°C(+4°C) above the setting temp, the compressor is turned off. When
below the setting temp, the compressor is turned on.
Compressor ON Temp. => Setting Temp.(+2°C)
Compressor OFF Temp. => Setting Temp.+3°C(+4°C)
• While in compressor on, the indoor fan is off when the indoor pipe temp. is below 26®¨C , when above 28°C , it
operates with the low or setting airflow speed (while in sleep mode, with the medium airflow speed).
• While in compressor off, the indoor fan is off when the indoor pipe temp is below 33°C , when above 35°C , it
operates with the low airflow speed.
• If overloaded while in heating mode operation, in order to prevent the compressor from OLP operation, the out-
door fan is turned on/off according to the indoor pipe temp.
• While in defrost control, both of the indoor and outdoor fans are turned off.
I Defrost Control
• While in heating mode operation in order to protect the evaporator pipe of outdoor unit from freezing, reversed
to cooling cycle to defrost the evaporator pipe of the outdoor unit.
• Defrost control is available 30 minutes later since heating mode operation started, and it will not prolong over 6
minutes.
• Deicing starts only when the outdoor pipe temperature falls below -6°C after 30 minutes passed from starting of
heating operating and more than 10 minutes operation of compressor.
• Deicing ends after 6 minutes passed from starting of deice operation or when the outdoor pipe temperature rises
over 12°C even if before 6 minutes.
I Fuzzy Operation (C/O Model)
• According to the temperature set by Fuzzy rule, when the intake air temp is 0.5°C or more below the setting
temp, the compressor is turned off. When 0.5°C or more above the setting temp, the compressor is turned on.
Compressor ON Temp => Setting Temp+0.5°C
Compressor OFF Temp => Setting Temp+0.5°C
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
Operation
- 30 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Operation
26°C ≤ Intake Air Temp => 25°C
24°C ≤ Intake Air Temp<26°C => Intake Air Temp+1°C
22°C ≤ Intake Air Temp<24°C => Intake Air Temp+0.5°C
18°C ≤ Intake Air Temp<22°C => Intake Air Temp
Intake Air Temp<18°C => 18°C
• When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
• While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the temper-
ature
I Fuzzy Operation (H/P Model)
• When any of operation mode is not selected like the moment of the power on or when 3 hrs has passed since
the operation off, the operation mode is selected.
• When determining the operation mode, the compressor, the outdoor fan, and the 4 way valve are off and only
the indoor fan is operated for 15 seconds. Then an operation mode is selected according to the intake air
temp at that moment as follows.
24°C ≤ Inatake Air Temp => Fuzzy Operation for Cooling
21°C ≤ Inatake Air Temp<24°C => Fuzzy Operation for Dehumidification
Inatake Air Temp<21°C => Fuzzy Operation for Heating
• If any of the operation modes among cooling / dehumidification / heating mode operations is carried out for 10
sec or longer before Fuzzy operation, the mode before Fuzzy operation is operated.
1) Fuzzy Operation for Cooling
• According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5°C or more below
the setting temp, the compressor is turned off. When 0.5°C or more above the setting temp, the compressor is
turned on.
Compressor ON Temp => Setting Temp+0.5°C
Compressor OFF Temp => Setting Temp+0.5°C
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
26°C ≤ Intake Air Temp => 25°C
24°C ≤ Intake Air Temp<26°C => Intake Air Temp+1°C
22°C ≤ Intake Air Temp<24°C => Intake Air Temp+0.5°C
18°C ≤ Intake Air Temp<22°C => Intake Air Temp
Intake Air Temp < 18°C => 18°C
• When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
• While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the temperature.
2) Fuzzy Operation for Dehumidification
• According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5°C or more below
the setting temp, the compressor is turned off. When 0.5°C or more above the setting temp, the compressor is
turned on.
Compressor ON Temp => Setting Temp+0.5°C
Compressor OFF Temp => Setting Temp+0.5°C
- 31 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
26°C ≤ Intake Air Temp => 25°C
24°C ≤ Intake Air Temp<26°C => Intake Air Temp+1°C
22°C ≤ Intake Air Temp<24°C => Intake Air Temp+0.5°C
18°C ≤ Intake Air Temp<22°C => Intake Air Temp
Intake Air Temp < 18°C => 18°C
• When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
• While in Fuzzy operation, the airflow speed of the indoor fan repeats the low airflow speed or pause as in dehu-
midification operation.
3) Fuzzy Operation for Heating
• According to the setting temperature selected by Fuzzy rule, when the intake air temp is 3°C(+4°C) or more
above the setting temp, the compressor is turned off. When below the setting temp, the compressor is turned
on.
Compressor ON Temp => Setting Temp(+2°C)
Compressor OFF Temp => Setting Temp + 3°C(+4°C)
• At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the
intake air temp at that time.
20°C ≤ Intake Air Temp => Intake Air Temp + 0.5°C
Intake Air Temp < 20°C => 20°C
• When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature
automatically according to the Fuzzy rule.
• While in Fuzzy operation, the airflow speed of the indoor fan is set to the high or the medium according to the
intake air temperature and the setting temperature.
I Airflow Speed Selection
• The airflow speed of the indoor fan is set to high, medium, low, or chaos by the input of the airflow speed selec-
tion key on the remote controller.
I On-Timer Operation
• When the set time is reached after the time is input by the remote controller, the appliance starts to operate.
• The timer LED is on when the on-timer is input. It is off when the time set by the timer is reached.
• If the appliance is operating at the time set by the timer, the operation continues.
I Off-Timer Operation
• When the set time is reached after the time is input by the remote controller, the appliance stops operating.
• The timer LED is on when the off-timer is input. It is off when the time set by the timer is reached.
• If the appliance is on pause at the time set by the timer, the pause continues.
Operation
- 32 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Operation
I Off-Timer <=> On-Timer Operation
• When the set time is reached after the on/off time is input by the remote controller, the on/off-timer operation is
carried out according to the set time.
I Sleep Timer Operation
• When the sleep time is reached after <1,2,3,4,5,6,7,0(cancel) hr> is input by the remote controller while in appliance
operation, the operation of the appliance stops.
• While the appliance is on pause, the sleep timer mode cannot be input.
• While in cooling mode operation, 30 min later since the start of the sleep timer, the setting temperature increases by
1°C After another 30 min elapse, it increases by 1°C again.
• When the sleep timer mode is input while in cooling cycle mode, the airflow speed of the indoor fan is set to the low.
• When the sleep timer mode is input while in heating cycle mode, the airflow speed of the indoor fan is set to the
medium.
I Chaos Swing Mode
• By the Chaos Swing key input, the vane automatically operates with the Chaos Swing or they are fixed to the
desired direction.
I Chaos Natural Wind Mode
• When the Chaos Natural Wind mode is selected and then operated, the high, medium, or low speed of the air-
flow mode is operated for 2~15 sec randomly by the Chaos Simulation.”
I Jet Cool Mode Operation (C/O Model)
• If the Jet Cool key is input at any operation mode while in appliance operation, the Jet Cool mode operates.
• In the Jet Cool mode, the indoor fan is operated at super-high speed for 30 min at cooling mode operation.
• In the Jet Cool mode operation, the room temperature is controlled to the setting temperature, 18°C
• When the sleep timer mode is input while in the Jet Cool mode operation, the Jet Cool mode has the priority.
• During the JET COOL function at any moment, the A/C starts to blow the cool air with side louvers closed at
extremely high speed for 30 minutes setting the room temp. automatically to 18°C.
I Jet Cool Mode Operation (H/P Model)
• While in heating mode or Fuzzy operation, the Jet Cool key cannot be input. When it is input while in the other
mode operation (cooling, dehumidification, ventilation), the Jet Cool mode is operated.”
• In the Jet Cool mode, the indoor fan is operated at super-high speed for 30 min at cooling mode operation.
• In the Jet Cool mode operation, the room temperature is controlled to the setting temperature, 18°C
• When the sleep timer mode is input while in the Jet Cool mode operation, the Jet Cool mode has the priority.
• During the JET HEAT function at any moment, the A/C starts to blow the hot air with side louvers closed at
extremely high speed for 60 minutes setting the room temp. automatically to 30°C.
CLOSED
OPEN
< Cooling Mode >
7°
CLOSED
OPEN
< Heating Mode >
7°
- 33 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
I Auto Restarting Operation
• When the power is restored after a sudden power failure while in appliance operation, the mode before the
power failure is kept on the memory and the appliance automatically operates in the mode on the memory.
• Operation Mode that is kept on the memory
- State of Operation ON/OFF
- Operation Mode/Setting Temp/Selected Airflow Speed
- Sleep Timer Mode/Remaining Time of Sleep Timer (unit of hour)
I Forced Operation
• Operation procedures when the remote control can't be used.
• The operation will be started if the power button is pressed.
• If you want to stop operation, re-press the button.
• While in forced operation, the key input by the remote control has no effect and the buzzer sounds 10 times to
indicate the forced operation.
I Test operation
• During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room tem-
perature and resets in 18±1 minutes.
• During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, open the front panel upward and Press the power button let it be pressed for
about 3 seconds.
• If you want to stop the operation, re-press the button.
I Protection of the evaporator pipe from frosting
• If the indoor pipe temp is below 0°C in 7 min. after the compressor operates without any pause while in cooling
cycle operation mode, the compressor and the outdoor fan are turned off in order to protect the indoor evapo-
rator pipe from frosting.
• When the indoor pipe temp is 7°C or higher after 3 min. pause of the compressor, the compressor and the out-
door fan is turned on according to the condition of the room temperature.
I Buzzer Sounding Operation
• When the appliance-operation key is input by the remote control, the short "beep-beep-" sounds.
• When the appliance-pause key is input by the remote control, the long "beep – beep" sounds.
• When a key is input by the remote control while the slide switch on the main unit of the appliance is on the
forced operation position, the error sound "beep-beep-beep-beep-beep-" is made 10 times to indicate that the
remote control signal cannot be received.
Operation
Heat pump Model
Cooling Model
Room Temp. ≥ 24°C 21°C ≤ Room Temp. < 24°C Room Temp. < 21°C
Operating mode
Cooling
Cooling
Healthy Dehumidification
Heating
Indoor Fan Speed
High
High
High
High
Setting Temperature
22°C
22°C
23°C
24°C
- 34 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Operation
I Air Cleaner Operation
• When an air cleaner function is selected during Air Conditioner operation
- Plasma air cleaner function will be operated while in any operation mode with selecting the function.
- The function is to be stopped while it is operating with selecting the function.
• When an air cleaner function is selected during operation off
- The function will be only operated.
• When inlet grille of air conditioner is opened during plasma operation, High Voltage Generator(H.V.B) is to be
stopped. When inlet grille of air conditioner is closed during plasma operation, High Voltage Generator(H.V.B)
will be operated again.
- 35 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Operation
Display Function
1. Heating Model
2. Cooling Model
• Cooling, Soft Dry, Fan, Heating
• Cooling, Soft Dry, Fan
• Sleep Mode
• Sleep Mode
• Timer Mode
• Timer Mode
• Hot-start, Defrost
Operation Indicator
Timer Indicator
Sleep Timer Indicator
Defrost Indicator
Operation Indicator
Timer Indicator
Sleep Timer Indicator
Outdoor Unit Operation
- 36 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Operation
Self-diagnosis Function
3sec
3sec
3sec
(once)
3sec
3sec
(twice)
3sec
(5times)
Error
Code
1
2
5
Error Display LED
(Indoor body operation LED)
Error contents
• Indoor room temperature
thermistor open/short
• Indoor pipe temperature
thermistor open/short.
• Outdoor pipe temperature
thermistor open/short.
• Poor communication.
• Indoor Thermistor
assembly check
• Outdoor Thermistor
assembly check
• Communication line/circuit
check
SVC check point
- 37 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Remote Control Operations
ON
OFF
CANCEL
SET
1
3
5
4
9
10
12
14
16
7
2
8
13
15
11
6
Cooling Operation
Auto Operation or Auto Changeover
Healthy Dehumidification Operation
Flip-up door
(opened)
Heating Operation
Signal transmitter
• Cooling Model(
), Heat Pump Model(
)
17
AUTO CLEAN
The controls will look like the following.
Operation Mode
1. START/STOP BUTTON
Operation starts when this button is pressed and
stops when the button is pressed again.
2. OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
3. ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
4. INDOOR FAN SPEED SELECTOR
Used to select fan speed in four steps
low, medium, high and CHAOS.
5. JET COOL/HEATING(OPTIONAL)
Used to start or stop the speed
cooling. (Speed cooling/heating operates at super
high fan speed in cooling/heating mode.)
6. CHAOS SWING BUTTON
Used to stop or start louver movement and set the
desired up/down airflow direction.
7. ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping opera-
tion.
8. TIME SETTING BUTTONS
Used to adjust the time.
9. TIMER SET/CANCEL BUTTON
Used to set the timer when the desired time is
obtained and to cancel the Timer operation.
10. SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation.
11. AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or
heating.
12. ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
13. NANO PLASMA(OPTIONAL)
Used to start or stop the plasma-purification
function.
14. HORIZONTAL AIRFLOW DIRECTION CONTROL
BUTTON
(OPTIONAL)
Used to set the desired horizontal airflow direction.
15. RESET BUTTON
Used prior to resetting time or after replacing bat-
teries.
16. 2nd F Button
Used prior to using modes printed in blue at the
bottom of buttons.
17. AUTO CLEAN(OPTIONAL)
Used to set Auto Clean mode.
Operation
Controls
- 38 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Disassembly
Disassembly
Indoor Unit
WARNING: Disconnect the unit from
power supply before making any
checks. Be sure the power switch is set
to "OFF"
To remove the Grille from the Chassis.
• Hold up Inlet Grille Horizentally.
• To remove the Grille, pull the lower left and right
side of the grille toward you (slightly tilted) and lift it
straight upward.
• To seperate connecter assembly and than to
remove Inlet Grille assembly.
1. Before removing the control box, be sure to
take out the wire screwed at the other end.
- 39 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Disassembly
2. To remove the Control Box.
• Remove securing screws.
• Pull the control box out from the chassis careful-
ly.
3. To remove the Discharge Grille.
• Unhook the discharge grille and pull the dis-
charge grille out from the chassis carefully.
4. To remove the Evaporator.
• Remove 3 screws securing the evaporator(at the
left 2EA in the Eva Holder, at the right 1EA).
- 40 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Disassembly
• Unhook the tab on the right inside of the chassis
at the same time, slightly pull the evaporator
toward you until the tab is clear of the slot.
5. To remove the Motor Cover
• Remove 2 securing screw.
• Pull the motor cover out from the chassis
carefully.
6. To remove the Cross-Flow Fan
• Loosen the screw securing the cross-flow fan to
the fan motor (do not remove).
• Lift up the right side of the cross-flow fan and the
fan motor, separate the fan motor from the
cross-flow fan.
• Remove the left end of the cross-flow fan from
the self-aligning bearing.
Motor cover
- 41 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Troubleshooting Guide
Troubleshooting Guide
INDOOR UNIT
OUTDOOR UNIT
INDOOR UNIT
OUTDOOR UNIT
HEAT
EXCHANGE
(EVAPORATOR)
HEAT
EXCHANGE
(EVAPORATOR)
HEAT
EXCHANGE
(CONDENSER)
HEAT
EXCHANGE
(CONDENSER)
COMPRESSOR
COMPRESSOR
ACCUMU
LATOR
GAS SIDE
GAS SIDE
3-WAY VALVE
LIQUID SIDE
LIQUID SIDE
3-WAY VALVE
CAPILLARY TUBE
CAPILLARY TUBE
CHECK VALVE
(Heating Model only)
COOLING
HEATING
REVERSING
VALVE
(Heating Model Only)
(1) Cooling Only Models
Refrigeration Cycle Diagram
(2) Cooling & Heating Models
- 42 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Troubleshooting Guide
2-way, 3-way Valve
2-way Valve (Liquid Side)
3-way Valve (Gas Side)
Shaft position
Shaft position
Service port
Closed
Closed
Closed
(with valve cap)
(with valve cap)
(with cap)
Open
Closed
Open
(counter-clockwise)
(clockwise)
(push-pin or with
vacumm pump)
Open
Open
Closed
(with valve cap)
(with valve cap)
(with cap)
Closed
Open
Open
(clockwise)
(counter-clockwise)
(connected manifold
gauge)
Open
Open
Open
(with charging
cylinder)
Open
Open
Open
(with charging
cylinder)
Open
Open
Open
Open
Works
Shipping
Air purging
(Installation)
Operation
Pumping down
(Transfering)
Evacuation
(Servicing)
Gas charging
(Servicing)
Pressure check
(Servicing)
Gas releasing
(Servicing)
1.
2.
3.
4.
5.
6.
Valve cap
Open position
Closed position
Pin
Service
port
Service
port cap
To outdoor unit
Flare nut
To
piping
connection
To outdoor unit
Hexagonal wrench (4mm)
Open position
Closed position
To
piping
connection
Flare nut
Open
(with charging cylinder)
Open
(with charging cylinder)
- 43 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Troubleshooting Guide
• Procedure
(1) Confirm that both the 2-way and 3-way valves
are set to the open position.
– Remove the valve stem caps and confirm that
the valve stems are in the raised position.
– Be sure to use a hexagonal wrench to operate
the valve stems.
(2) Operate the unit for 10 to 15 minutes.
(3) Stop operation and wait for 3 minutes, then
connect the charge set to the service port of
the 3-way valve.
– Connect the charge hose with the push pin to
the service port.
(4) Air purging of the charge hose.
– Open the low-pressure valve on the charge set
slightly to air purge from the charge hose.
(5) Set the 2-way valve to the closed position.
(6) Operate the air conditioner at the cooling
cycle and stop it when the gauge indicates
1kg/cm2g.
(7) Immediately set the 3-way valve to the closed
position.
– Do this quickly so that the gauge ends up indi-
cating 3 to 5kg/cm2g.
(8) Disconnect the charge set, and mount the 2-
way and 3-way valve’s stem nuts and the ser-
vice port nut.
– Use torque wrench to tighten the service port
nut to a torque of 1.8 kg.m.
– Be sure to check for gas leakage.
Lo
Closed
Purge the air
Outdoor unit
Indoor unit
Liquid side
Gas side
CLOSE
Open
2-Way
valve
3-Way
valve
CLOSE
Pumping Down
- 44 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Troubleshooting Guide
Balance Refrigerant of the 3-way Valve
(Gas leakage)
• Procedure
(1) Confirm that both the 2-way and 3-way valves
are set to the back seat.
(2) Connect the charge set to the 3-way valve’s
port.
– Leave the valve on the charge set closed.
– Connect the charge hose to the service port.
(3) Open the valve (Lo side) on the charge set and
discharge the refrigerant until the gauge indi-
cates 0 kg/cm2G.
– If there is no air in the refrigerant cycle (the
pressure when the air conditioner is not running
is higher than 1 kg/cm2G), discharge the refrig-
erant until the gauge indicates 0.5 to 1
kg/cm2G. if this is the case, it will not be neces-
sary to apply a evacuatin.
– Discharge the refrigerant gradually; if it is dis-
charged too suddenly, the refrigeration oil will
also be discharged.
Lo
Open
Open
3-Way
valve
3-Way
valve
Gas side
CLOSE
OPEN
Outdoor unit
Liquid side
Indoor unit
- 45 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Troubleshooting Guide
Evacuation
(All amount of refrigerant leaked)
• Procedure
(1) Connect the vacuum pump to the center hose
of charge set center hose
(2) Evacuation for approximately one hour.
– Confirm that the gauge needle has moved
toward -76 cmHg (vacuum of 4 mmHg or less).
(3) Close the valve (Lo side) on the charge set,
turn off the vacuum pump, and confirm that
the gauge needle does not move (approxima-
tely 5 minutes after turning off the vacuum
pump).
(4) Disconnect the charge hose from the vacuum
pump.
– Vacuum pump oil.
If the vacuum pump oil becomes dirty or
depleted, replenish as needed.
Lo
Open
Open
Vacuum pump
3-Way
valve
Outdoor unit
Liquid side
Indoor unit
Gas side
3-Way
valve
CLOSE
OPEN
- 46 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Troubleshooting Guide
Gas Charging
(After Evacuation)
• Procedure
(1) Connect the charge hose to the charging
cylinder.
– Connect the charge hose which you dis-con-
nected from the vacuum pump to the valve at
the bottom of the cylinder.
– If you are using a gas cylinder, also use a
scale and reverse the cylinder so that the sys-
tem can be charged with liquid.
(2) Purge the air from the charge hose.
– Open the valve at the bottom of the cylinder
and press the check valve on the charge set to
purge the air. (Be careful of the liquid refriger-
ant). The procedure is the same if using a gas
cylinder.
(3) Open the valve (Lo side on the charge set and
charge the system with liquid refrigerant.
– If the system can not be charged with the spec-
ified amount of refrigerant, it can be charged
with a little at a time (approximately 150g each
time) while operating the air conditioner in the
cooling cycle; however, one time is not suffi-
cient, wait approximately 1 minute and then
repeat the procedure (pumping down-pin).
(4) Immediately disconnect the charge hose from
the 3-way valve’s service port.
– Stopping partway will allow the gas to be dis-
charged.
– If the system has been charged with liquid
refrigerant while operating the air conditioner
turn off the air conditioner before disconnecting
the hose.
(5) Mount the valve stem nuts and the service
port nut.
– Use torque wrench to tighten the service port
nut to a torque of 1.8 kg.m.
– Be sure to check for gas leakage.
\
This is different from previous procedures.
Because you are charging with liquid refrigerant
from the gas side, absolutely do not attempt to
charge with larger amounts of liquid refrigerant
while operating the air conditioner.
Lo
Charging
cylinder
Outdoor unit
Indoor unit
Liquid side
Gas side
CLOSE
Open
3-Way
valve
3-Way
valve
OPEN
Open
Check valve
(1)
- 47 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Troubleshooting Guide
Trouble analysis
1. Check temperature difference between intake and discharge air and operating current.
Temp. Difference
Temp. difference : approx. 0°C
Current : less than 80% of
rated current
Temp. difference : approx. 8°C
Current : less than 80% of
rated current
Temp. difference : less than 8°C
Current : over the reated
current
Temp. difference : over 8°C
Operating Current
• All amount of refrigerant leaked
out. Check refrigeration cycle.
• Refrigerant leakege
Clog of refrigeration cycle
Defective compressor
• Excessive amount of refrigerant
• Normal
Temperature difference between intake and discharge air depends on room air humidity. When the room air
humidity is relativery higher, temperature difference is smaller. When the room air humidity is relatively lower tem-
perature difference is larger.
2. Check temperature and pressure of refrigeration cycle.
1. The suction pressure is usually 4.5~6.0 kg/cm2G(Cooling) at normal condition.
2. The temperature can be measured by attaching the thermometer to the low pressure tubing and wrap it with
putty.
NOTICE
NOTICE
Suction pressure
Temperature
(Compared with
(Compared with
Cause of Trouble
Description
the normal value)
the normal valve)
Defective compressor
Current is low.
Defective 4-way reverse valve
Excessive amount of
High pressure does not quickly
Normal
refrigerant
rise at the beginning of
operation.
Insufficient amount of
Current is low.
Lower
Higher
refrigerant (Leakage)
Clogging
Current is low.
High
Higher
Cycle Parts
- 48 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Troubleshooting Guide
Electronic Parts
Product does not operate at all.
(* Refer to Electronic Control Device drawing and Schematic diagram.)
Turn off Main Power
Turn on Main Power
Does "beeping" sound is made from the Indoor Unit?
Primarily, the operating condition of Micom is OK.
Check the voltage of power(About AC 220V, 60Hz)
(About AC 220/240V, 50Hz)
• Main power's voltage
• Voltage applied to the unit
• Connecting method of Indoor/Outdoor connecting
cable
• Check PWB Assembly
- Fuse
- Pattern damage
- Varistor(ZNR01N)
Check the connection housing for contacting
• Connector related to CN-POWER1, 2
• Connector related to CN-MOTOR
• Connector contacting of Outdoor Fan/Compressor
• Display PWB Assembly Check
Check each load(Indoor/Outdoor Fan Motor,
Compressor, Stepping Motor) and contacting
condition of related connector
Main PCB Board Operation Check
Items
• SMPS Transformer
(Indoor unit)
- Input Voltage
- Output Voltage
• IC04D(7805) Output
• IC01A(Reset IC)
OSC01B(8MHz)
• Replace Trans
• Replace IC04D
• Replace faulty parts
- About AC220V/240V±10% - Check the power voltage
- About DC12V
• DC +5V
• Voltage of Micom No. 36,
(DC +4.5V over) and Soldering condition.
Content
Remedy
NO
YES
(After 10 seconds)
- 49 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Troubleshooting Guide
The product does not operate with the remote controller.
Turn on Main Power
While the compressor has been stopped, the compressor does not
operate owing to the delaying function for 3 minutes after stopped.
Caused by other parts except the remote control
Cause by the remote control
When the mark( ) is displayed in LCD screen, replace
battery.
Check the contact of CN-D1, 2 connector.
When the compressor stopped Indoor Fan is driven by a low speed.
At this point the wind speed is not controlled by the remote controller.
(When operated in the Sleeping Mode, the wind speed is set to the
low speed by force.)
Check Display PWB Assembly
- Voltage between CN-D2
-
: DC +5V
Check the connecting circuit between the remote controller
MICOM (No. 30) - R17(2Ω) - IR LED - TR - R16(2.2KΩ).
Check point
• Check the connecting circuit between PIN
-
R02L(1K) - C01L(680PF) - MICOM PIN 43
• Check Receiver Assembly
- 50 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Troubleshooting Guide
Compressor/Outdoor Fan are unable to drive.
Turn on Main Power
Operate "Cooling Mode( )" by setting the desired temperature of the
remote controller is less than one of the indoor temperature by 1°C at least.
When in Air Circulation Mode, Compressor/Outdoor Fan is stopped.
Check the sensor for indoor temperature is attached as close as to be
effected by the temperature of Heat Exchanger(EVA).
When the sensor circuit for indoor temperature and connector are in bad
connection or are not engaged, Compressor/Outdoor Fan is stopped.
• Check R02H(12.1k), R04H(6.2k), Micom Pin 26, 27
• Check the indoor temperature sensor is disconnected or not(About 10kΩ / at 25°C).
Turn off Main Power
• Check the electrical wiring diagram of outdoor side.
• Check the abnormal condition for the component of
Compressor/Outdoor Fan Motor.
• Check the "open" or "short" of conmecting wires between indoor and
outdoor.
Check Relay(RY - COMP) for driving compressor.
• When the power(About AC220V/240V) is applied to the connecting wire
terminal support transferred to compressor, PWB Assembly is normal.
• Check the circuit related to the relay.
Check point
COMP ON
COMP OFF
Between Micom(No.
DC5V
DC0V
63) and GND
Between IC02M(No. 14)
Below DC 1V
About DC12V
and GND
(app)
- 51 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Troubleshooting Guide
When Indoor Fan does not operate.
Fan can't operate for dehumidifying mode.
- Change operation for cooling mode.
Turn off Main power
Check the connection of CN-MOTOR1, 2
Check the Fan Motor
Check the Fuse(AC250V/3.15A)
Turn ON Main Power
- Check PWM signal from Micom Pin 50
- Check On/Off signal from micom pin14.
- Check Voltage of CN-Motor 1, 2
(pin
~
is about 15V)
- 52 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Troubleshooting Guide
When Louvers do not operate.
• Confirm that the Louver is normally geared with the shaft of Stepping
Motor.
• If the regular torque is detected when rotating the Louver with hands
Normal
• Check the connecting condition of CN-UD, LR1, LR2 Connector.
• Check the soldering condition(on PWB) of CN-UD LR1, LR2 Connector.
If there are no problems after above checks
• Confirm the assembly conditions that are catching and interfering parts
in the rotation radial of the Louvers.
Check the operating circuit of the Louvers.
• Confirm that there is DC +12V between pin
of CN-UD and GND.
• Confirm that there is a soldering short at following terminals.
- Between
,
,
, , , , ,
,
, , , of MICOM
- Between
of IC02M
- Between
,
of IC03M
- Between
,
,
,
,
,
,
,
of IC04M
- Between
,
,
,
of CN-UD/LR1/LR2
45
46
47
48
54
55
56
57
59
60
61
62
- 53 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Troubleshooting Guide
When Heating does not operate
Operate “Heating Mode( )” by setting the desired temperature of the
remote control is higher than one of the indoor temperature by 2°C at
least.
In heating Mode, the indoor fan operates in case the pipe temperature
is higher than 28°C.
Check the connector of intake and pipe sensor(thermistors)
• Check the related circuit of RY-4WAY
• Check the indoor room temperature is disconnected or not (about
10KΩ/at 25°C).
• Check the indoor pipe temperature is disconnected or not (about
5KΩ/at 25°C).
Turn ON Main Power
Check the DC voltage on the PWB ASSEMBLY
• The details of check are as followings
Check point
Between Micom
(NO.63) and GND
Between IC02M
(NO.14) and GND
Comp ON
DC 5V
Below DC 1V
Comp OFF
DC 0V
About DC
12V
Check point
Between Micom
(NO.51) and GND
Between IC03M
(No.9) and GND
4 way ON
DC 5V
Below DC1V
4 way OFF
DC 0V
About 12V
Check point
Between Micom
(NO.53) and GND
Between IC03M
(NO.11) and GND
Fan ON
DC 5V
Below DC 1V
Fan OFF
DC 0V
About DC 12V
• Comp Relay.
• 4 way Relay
• Outdoor fan Relay
- 54 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Troubleshooting Guide
Turn off Main Power
• Check the electrical wiring diagram of outdoor side.
• Check the abnormal condition for the component of
Compressor/Outdoor Fan Motor, 4 way.
• Check the "open" or "short" of connecting wires between indoor and
outdoor.
- 55 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Schematic Diagram
Schematic Diagram
36
13
23
17
15
16
14
18 1920
21 22
29
24 25 26
27 28
32
30 31.
33
34
35
58
11
9
10
12
6
7
5
4
8
64
1
2
3
63 62 61
60 59
41
38
40
39
37
43
44
45
42
52
57 56 55
54 53
49
51 50
48
47
46
IC01M
R02F
20K
20K
R02P
KID65004AF
220
10V SD
C10D
+
103
50V
C08D
BZX55C11
C06D
25V SD
C07D
104
50V
330
20K
R02D
ZD02D
1
3
AC PART
5V
1
CN-12V
2
CN-CONT
1
2
HVB
2
1
3
IC04D
78L05BP
7805
O
I
12V
L4 100nH
20K 2012
R11H~R14H
2
1
CN-HVB(BL)
3
SDA
OJ1H
R13H
R11H
R12H
5V
R14H
4 A0
EEPROM
OJ2H
OJ3H
5
SCL
WP
Vcc
1
2
G
A2
3 A1
8
7
6
20K
R01P
1
RD
Sub Part
3
4
PK
YL
OR
2
5
BL
1
HVB OUT
9
INDOOR FAN
3
4
2
CN-U/D(WH)
5
COMP
3.6V
KIA7036P
RESET
CN-TH1(WH)
D07D
SD01D
IC01D
TNY266P
STO2D-200
UG2D
472M 3KV
DC LOW
IC02D
TLP421(BL)
C05D
4
6
1/8W 2012
39
R03D
470/35V/SD
C04D
+
S
104
C02D
BP
EN
D 5
4
1
2
IC03D
TLP421 BL
15uF
450V/SD
C01D
+
INT
1/8W 2012
4
3
2
1
27k
R04D
5V
1/4W
1N4148
D02D
300K
R05D
O/L
OR3H
SMPS
OJ4H
5V
5V
OR5H
OR6H
Hi
Med
OR4H
Low
1
d
V
A
d
s
s
V
A
AVref
AVdd
NTC SCK-102
D05D
1N4007
R05H
OR1H
F1
OR2H
F2
R25H
R26H
R24H
R21H
5V
0.01
50V
C01A
R21H~R26H
12.1K, 1%
R22H
R23H
5V
2
10K
12.1K
R02H
6.2K
1%
R04H
1%
5V
15mH/1A
NF01J
1/4W 3216
R06D
300K
BD01D~04D
1N4007
47nM/275V/435D
C03J
100nF/275V/436D
METAL FILM
METAL FILM
C02J
250V/T2A
100nM/275V/436D
METAL FILM
C01J
FUSE
TVR10561
ZNR01J
CN-TAB1
N
1
1
T-BLOCK
RY-COMP
G4A-1A-E-LG
4
3
2
1
2
1
INDOOR FAN
12V
ROOM-TH
PIPE-TH
2
1
1
3
2
3
4
4
680
R03J
1/2W
TRAICS
SM1L43
100,1/2W
R01J
120, 1/2W
R02J
TR01J
T1
1/4W
R04J
560
ZNR02J
TVR10561
TLP762JF
IC01J
1
2
3
5
4
3
3
2
1
2
1
CN-MOTOR
FAN
INDOOR
MOTOR
KID65004AF
1
UPD780023AGC-C
Vss0
5V
Vdd0
8
NEC
X2
Vss1
X1
INT0
INT1
BL
2
3
4
6
5
7
11
4WAY
FAN
15 14
16
2
1
13 12
5 6
4
3
IC02M
10 9
7
8
12V
YL OR
RD
PK
4
4
2
2
3
3
1
1
5
5
CN-L/R(BL)
CSTS0800MG03-T2
R02A,20K
1M
5V
R01B
CRTL8.00MSOT
OSC01B
3
1
Q01C
2SC5343
KTC3198-Y
5V
INT
5V
IC01A
12K
R07D
56K
R08D
AC220~240V
50/60Hz
SH-CAPACITOR
2012
2012
T2
VOLTAGE GND
DC HIGH
VOLTAGE GND
DC HIGH
VOLTAGE GND
DC HIGH
VOLTAGE GND
DC LOW
VOLTAGE GND
KID65004AF
IC01G
3
2
8
1
9
5
6
4
7
RD
OR
YL
BL
PK
3
3
2
2
1
1
CN-SUC(WH)
5
5
4
4
1
2
2
3
1
4
12V
R06V
220
R05V
10K
VFD DISPLAY
KTB 1151-Y
Q01V
STEPPING MOTOR
(UP/DOWN)
SUCTION 1
STEPPING MOTOR
STEPPING MOTOR
SUCTION 2
12V
12V
12V
SW PWB ASM
BZ
YL
OR
PK
2
2
3
3
4
4
5
5
3
3
RD
OR
BL
2
2
1
1
YL
BL
PK
5
5
4
4
RD
1
1
12V
1
1
2
3
3
2
7
5
6
8
9
5
7
6
5V
CN-VFD(WH)
C01F
50V
0.01
1K
R01F
C01L
50V
681
R02L,1K
C03~04V
0.01
50V
R01L
5.1K
2(N)
1(L)
COMPRESSOR
OUTDOOR
FAN MOTOR
RY-4WAY
RY-FAN
R03T
1K
102
C03T
Q01T
5V
A104S
Q04T
C104S
102
C02T
Q06T
A104S
Q03T
C104S
5V
CN-TEL
D01T
5V
1N4148
C01T
104
2
3
1
2
3
1
100
KRC107S
KRA107S
R02E
910
R03E
220
BZ01E
C01E
100/25V
+
PKM17EPP-2002
12V
Q02E
KRC107S
Q01E
Q03E
R01E
BZ FREQ
Bz
Bz
o2
5V
8
R04V,1K
R03V,1K
2
2
3
3
1
1
5
5
4
4
1
1
L
RY-O2
CN-TAB2
8
7
6
5
4
2
3
1
12V
HVB OUT
2
1
3
2
1
3
12V
E2 1K
E3 1K
5V
Vout
Vout
ZBF503D
L1
SMD 2012
�����
�������
�������
�������
�����
���
4
4
4
4
3
3
2
2
1
1
2
2
3
3
4
4
1
1
7
7
6
6
11
10
C01Z
0.01
C02Z
0.01
5
11
10
9
8
7
6
Q02V
KRA107S
C07V
104
10V SD
220
C09D
+
5
4
5
4
OPTION
6
6
JP11,330
Electric Control Device
- 56 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
AS-H1863*M3
AS-H2463*M3
LS-H1863*M3
LS-H2463*M3
LS-C1863*M3, LS-C2463*M4
Wiring Diagram
Schematic Diagram
Indoor Unit
Heat pump
Cooling only
3854A20238K
FUSE
AC250V/T2A
CN-TH1(WH)
TRIAC
SH-CAPA.
BL
BR
GN/YL
BR
YL
OR
BK
CN-TAB1
CN-MOTOR
CN-TAB2
CN-4WAY
/FAN/O2
CN-SW/2
CN-SW/3
CN-STEP2
CN-STEP1
CN-MAIN
CN-SW/1
RY-COMP.
RY-4WAY
RY-FAN
FORCED
OPERATON
S/W
SUC
STEP
MOTOR-1
ZNR
THERMISTOR
DISPLAY
MOTOR
MAIN PCB
ASM
POWER
TO OUTDOOR UNIT
TERMINAL
BLOCK
CONNECTOR
PWB ASM
BR
BL
BK
RD
GN/YL
BR
BL
BK
RD
GN/YL
1(L) 2(N)
3 4
3
4
BL
BR
CN-U/D(WH)
CN-DISP1
STEP
MOTOR
CN-L/R(BL)
CN-HVB
STEP
MOTOR
OPTION
OPTION
LIMIT S/W-1
LIMIT S/W-2
H.V.B
A/CL
RD
RD
BK
BK
SUC
STEP
MOTOR-2
3854A20238N
FUSE
AC250V/T2A
CN-TH1(WH)
TRIAC
SH-CAPA.
BL
BR
GN/YL
BR
YL
OR
BK
CN-TAB1
CN-MOTOR
CN-TAB2
CN-SW/2
CN-SW/3
CN-STEP2
CN-STEP1
CN-MAIN
CN-SW/1
RY-COMP.
FORCED
OPERATON
S/W
SUC
STEP
MOTOR-1
ZNR
THERMISTOR
DISPLAY
MOTOR
MAIN PCB
ASM
POWER
TO OUTDOOR UNIT
INDOOR WIRING DIAGRAM
TERMINAL
BLOCK
CONNECTOR
PWB ASM
BR
BL
GN/YL
BR
BL
GN/YL
1(L) 2(N)
3
4
BL
BR
CN-U/D(WH)
CN-DISP1
STEP
MOTOR
CN-L/R(BL)
CN-HVB
STEP
MOTOR
OPTION
OPTION
LIMIT S/W-1
LIMIT S/W-2
H.V.B
A/CL
RD
RD
BK
BK
SUC
STEP
MOTOR-2
- 57 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Schematic Diagram
Outdoor Unit
LS-C2423_Series
LS-C2463_Series
LS-C1823_Series
LS-C1863*M3
LS-H1823_Series
RD
BR(OR)
OPTION
PTC
YL
BK
(BR)
C
R
S
COMP.
BK
OR
YL
FAN
MOTOR
TP
H
C
F
TO INDOOR UNIT
OUTDOOR WIRING DIAGRAM 3854A20167T
TERMINAL
BLOCK
HIGH PRESSURE
SWITCH
SOLENOIDE
VALVE
BR
BL
GN/YL
GN/YL
GN/YL
T/B
CAPACITOR
1(L) 2(N)
LS-C1823R/W/B/D/M/CM2
LS-C1863_Series
LS-C2463_Series
AS-H1863_Series
AS-H2463_Series
LS-H2423_Series
LS-H2463_Series
LS-H1863_Series
LS-H2463*M3
AS-H1863RM0
C
S
R
RD
YL
YL
GN/YL
GN/YL
GN/YL
BR
BL
BK
RD
YL
YL
BR(OR)
BL
BK
FAN
MOTOR
BR
BL
BK
RD
HEATER
RD
BR
BR
WH
BK(RD)
BK(RD)
RD
T/B1
T/B3
T/B4
T/B2
REVERSING
VALVE
TERMINAL
BLOCK
TO INDOOR UNIT
3854A20167Q
RY-S/CAPA
RY-COMP
SOFT STARTER PCB
COMP.
START
CAPACITOR
OPTION
PTC
CAPACITOR
4
H
C
F
3
4
3
1(L) 2(N)
3 4
AS-H2463R/D/M/WM1
- 58 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Schematic Diagram
Components Location
MAIN P.W.B ASSEMBLY (AC PART)
• TOP VIEW
800V
PWB ASM: 6871A10043
PWB: 6870A90177A
• BOTTOM VIEW
- 59 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Schematic Diagram
DISPLAY ASSEMBLY
SUB P.W.B ASSEMBLY
1
1
1
CN-12V(WH)
1
CN-D6
CN-D7
1
CN-D8
CN-D5
1
1
1
1
CN-CON(WH)
CN-SW(BL)
1
C01V
PWB ASM:6871A20363
PWB:6870A90126B
CN-D3
CN-D1
1
CN-D2
1
CN-D4
C02V
- 60 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Product Specifications
Product Specifications
Table-1
Model Name
Item Unit
Cooling Capacity
Btu/h
Heating Capacity
Moisture Removal
l/h
Power Source
Ø, V, Hz
Cooling
W
Heating
Running
Cooling
A
Current
Heating
E.E.R.
Cooling
Btu/hW
C.O.P
Heating
Refrigerant
g
Airflow Direction Control (Up & Down)
Remocon Type
inch(mm)
Sleeping Operation
Drain Hose
Connecting Cable(p*mm2)
Power Cord(p*mm2)
18,000
24,000
18,000
24,000
22,500
19,000
24,000
19,000
24,000
22,500
2
3
2
3
3
1, 220-240, 50
1, 220-240, 50
1, 220, 60
1, 220, 60
1, 220-240, 50
13
15.5
13
15.5
15.5
42
48
34
48
48
40
44
40
44
44
51
55
51
55
55
1,860
2,700
1,860
2,525
2,500
1,870
2,650
1,730
2,525
2,500
9.2
12.6
8.5
12
11.0
9.2
12.6
8.1
12
11.0
9.7
8.9
9.68
9.5
9
2.98
2.65
3.2
2.78
2.65
26.7
26.7
15.7
30
26.7
61
82.9
45
67.2
82.9
1170*315*170
1170*315*170
1170*315*170 1170*315*170
1170*315*170
870*655*320
870*655*320 801*555*262 870*655*320 870*655*320
13(28.7)
13(28.7)
13(28.7)
13(28.7)
13(28.7)
60(132)
60(132)
38
60(132)
60(132)
1310
1500
1360
1470
1480
O
O
O
O
O
L.C.D Wireless
L.C.D Wireless
L.C.D Wireless L.C.D Wireless
L.C.D Wireless
1/4(6.35)
3/8(9.52)
1/4(6.35)
3/8(9.52)
3/8(9.52)
1/2(12.7)
5/8(15.88)
5/8(15.88)
5/8(15.88)
5/8(15.88)
O
O
O
O
O
O
O
O
O
O
14:3*1.5
12:3*2.5
14:3*1.5
12:3*2.5
12:3*2.5
14:3*1.5
12:3*2.5
14:3*1.5
12:3*2.5
12:3*2.5
Air Circulation
Noise Level
Input
m3/min
dB (A)±3
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Liquid
Gas
Service Valve
Motor Output
Dimensions
(W x H x D)
Net. Weight
W
mm
kg
LS-H1863*M0
LS-H1863*M1
LS-H1863*M3
LS-H2463*M0
LS-H2463*M3 LS-H1823*M0 LS-H2423*M0 AS-H2463*M0
- 61 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Table-2
Product Specifications
Model Name
Item Unit
Cooling Capacity
Btu/h
Heating Capacity
Moisture Removal
l/h
Power Source
Ø, V, Hz
Cooling
W
Heating
Running
Cooling
A
Current
Heating
E.E.R.
Cooling
Btu/hW
C.O.P
Heating
Refrigerant
g
Airflow Direction Control (Up & Down)
Remocon Type
inch(mm)
Sleeping Operation
Drain Hose
Connecting Cable(p*mm2)
Power Cord(p*mm2)
18,000
24,000
18,000
18,000
24,000
18,000
24,000
-
-
-
-
-
18,900
24,500
2
3
2
2
3
2
3
1, 220~240, 50
1, 220-240, 50
1, 220, 60
1, 220, 60
1, 220, 60
1,220~240,50
1,220~240,50
13
15.5
13
13
15.5
13
15.5
42
48
34
48
48
42
48
40
44
40
42
44
40
44
51
55
51
53
55
51
55
1,900
2,700
1,950
1,830
2,400
1,750
2,550
-
-
-
-
-
1,730
2,475
9.4
12.8
9
8.5
11
8
10.5
-
-
-
-
-
8
10.5
9.47
8.9
9.23
9.38
10
10.28
9.38
-
-
-
-
-
10.92
9.889
26.7
26.7
15.7
15.7
30
25.6
25.6
61
82.9
45
76.5
76.5
61
82.9
1170*315*170
1170*315*170
1170*315*170
1170*315*170
1170*315*170
1170*315*170
1170*315*170
870*655*320
870*655*320
801*555*262
870*577*276
840*577*276
870*655*320
870*800*320
13(28.7)
13(28.7)
13(28.7)
13(28.7)
13(28.7)
13(28.7)
13(28.7)
56(123.5)
60(132)
38
42(92.4)
47(103.6)
60(132)
65(140.5)
1,140
1,470
1,240
1,300
1,270
1,210
1,980
O
O
O
O
O
O
0
L.C.D Wireless L.C.D Wireless L.C.D Wireless L.C.D Wireless L.C.D Wireless L.C.D Wireless L.C.D Wireless
1/4(6.35)
3/8(9.52)
1/4(6.35)
1/4(6.35)
3/8(9.52)
1/4(6.35)
3/8(9.52)
1/2(12.7) 5/8(15.88) 5/8(15.88) 5/8(15.88) 5/8(15.88) 1/2(12.7) 5/8(15.88)
O
O
O
O
O
O
0
O
O
O
O
O
O
0
14:3*1.5
12:3*2.5
14:3*1.5
14:3*1.5
12:3*2.5
14:3*1.5
12:3*2.5
14:3*1.5
12:3*2.5
14:3*1.5
14:3*1.5
12:3*2.5
14:3*1.5
12:3*2.5
Air Circulation
Noise Level
Input
m3/min
dB (A)±3
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Indoor
Outdoor
Liquid
Gas
Service Valve
Motor Output
Dimensions
(W x H x D)
Net. Weight
W
mm
kg
LS-C1863*M0
LS-C1863*M3
LS-C2463*M1
LS-C2463*M0
LS-C2463*M3
LS-C2463*M4
LS-C1823*M1
LS-C1823*M0
LS-C1823*M2
LS-C2423*M0
AS-H1863*M0
AS-H1863*M3
AS-H2463R/D/M/WM1
AS-H2463*M0
AS-H2463*M3
- 62 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Exploded View
Exploded View
352116
352150
145200B
145200C
145200D
354210
147581
249951
264110
W0CZZA
733010
131410
146811A
135311
342800
267110
359011
159830
146811B
145200A
268711C
135316
146811B
268711D
152302
135516
268711B
35211B
266090
268711A
237900
263230
346810
352115
Indoor Unit
135313
- 63 -
Exploded View
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
352116
352150
145200B
145200C
145200D
354210
147581
249951
264110
W0CZZA
733010
131410
146811A
135311
342800
267110
359011
159830
146811B
145200A
268711C
135316
146811B
268711D
152302
135516
268711B
35211B
266090
268711A
263230
346810
352115
Indoor Unit(Panel Mirror Type)
135313
- 64 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Exploded View
554031
437212
435511
552202
552116
554160
550140
552203A
552203B
430411
435301
447910
552111
437210
559010
435512
546810
349600
561410
W0CZZB
649950
Applied for
Heating Model
Outdoor Unit
- 65 -
Exploded View
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
554031
437212
435511
552202
552116
554160
550140
552203A
552203B
430411
447910
552113
559010
546810
349600
561410
649950
Applied for
Heating Model
437210
435301
Outdoor Unit (UM Chassis)
- 66 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Exploded View
554031
437212
435511
552202
552116
554160
550140
552203A
552203B
430411
435301
447910
552111
437210
559010
435512
546810
349600
561410
649950
Applied for
Heating Model
Outdoor Unit (UD Chassis)
- 67 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
435300
435512
137213B
137213A
554031
552202
552116
435511
554160
561410
550140
552203B
552203A
430411
437210
649950
W0CZZB
552102
559010
435301
546810
447910
Applied for
Heating Model
Outdoor Unit
Exploded View