LG LDE3019ST Installation Manual

Specifications

Brand: LG
Category: Oven
Model: LDE3019ST (Installation Manual)
File Type: PDF
File Size: —
Pages: 11

Read Online

Read the LG LDE3019ST Installation Manual online using the built-in PDF viewer.

Text of the manual

ELECTRIC DOUBLE OVEN RANGE

LDE3019ST LDE3017ST LDE3017SB LDE3017SW Please read these instructions thoroughly before installing and operating the range. P/No.: MFL63290401 www.lg.com ENGLISH ESPAÑOL LDE3015ST LDE3015SB LDE3015SW

BEFORE YOU BEGIN

Remove all tape and packing materials before using the range. Dispose of all plastic bags after unpacking the range. Never allow children to play with packing materials. IMPORTANT SAFETY INSTRUCTIONS Read and follow all instructions before using your oven to prevent the risk of fire, electric shock, personal injury, or damage when using the range. This guide does not cover all possible conditions that may occur. For further assistance contact your service agent or manufacturer. 1 Gloves Safety Glasses Tape Measure Pencil This symbol will alert you to hazards or unsafe practices which could cause serious bodily harm or death. Gloves Safety Glasses Tape Measure Pencil WARNING This symbol will alert you to hazards or unsafe practices which could cause bodily injury or property damage. Gloves Safety Glasses Tape Measure Pencil CAUTION WARNING • The information in this manual should be followed exactly. - A fire or electrical shock may result causing property damage, personal injury or death. • Any person should not step or sit on the oven door. You should install the Anti-Tip Bracket supplied with the range. - The range could be tipped and injury might result from spilled hot liquid, food, or the range itself. - If the range is pulled away from the wall for cleaning, service, or any other reason, ensure that the Anti-Tip Device is properly reengaged when the range is pushed back against the wall. • You should use two or more people to move and install range. (Excessive Weight Hazard) - Failure to do so can result in back or other injury. • You never pull or push any handles of upper& lower door to move and install range. - Failure to do so can result in serious damage to the door of the range. • New branch-circuit installations (1996 NEC) for mobile homes, recreational vehicles, and installations where local codes do not allow grounding through the neutral wire require a 4-conductor UL listed range cord or 4 wire conduit connection. • Power supply cord and plug should not be modified. If it will not fit the outlet, have a proper outlet Installed by a qualified electrician. • Using an extension cord to connect the power is prohibited. The way to connect the power cord and plug directly is strongly recommended. • Electrical ground is required on this appliance. • You should make sure that the power cord is not pinched by the range or heavy objects. - Failure to do so can result in serious burns or electrical shock. • You never remove the protection cover covering the rear of lower oven. - Failure to do so can result in serious damage to power cord. The damage causes serious burns and electric shock. This is the safety alert symbol. This symbol alerts you to potential hazards that can cause personal injury to you and others. All safety messages will follow the safety alert symbol with either the word “WARNING” or “CAUTION”.

• The middle (neutral or ground) wire of a 3 wire power cord or a 3 wire conduit has to be

connected to the middle post of the main terminal block. The remaining two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block. - Failure to do so can result in electrical shock, severe personal injury or death. • Only a 4-conductor power-supply cord kit rated 120/240 volts, 50 amperes and marked for use with ranges with closed-loop connectors or open-end spade lugs with upturned ends shall be used. The middle (neutral) wire of the power cord or 4-wire conduit has to be connected to the middle post of the main terminal block. The other two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block. The 4th ground wire must be connected to the frame of the range with the ground screw. - Failure to do so can result in electrical shock, severe personal injury or death. CAUTION • You should put on gloves during the installation procedure. - Failure to do so can result in bodily injury. • You should make sure that the wall covering, countertop and cabinets around the range can withstand the heat (up to 194°F) generated by the range. - Discoloration, delamination or melting may occur. - This range has been designed to comply with the maximum allowable wood cabinet temperatures of 194°F. • Cabinet storage space located above the surface units should be avoided. • You should install a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets. If cabinet Storage is to be provided. - The risk of burns or fire by reaching over the heated surface elements can be reduced. • You should not install the range in the humid place. Splashing the range with water or any electrolyte can result in electrical shock. • You should not let cooking grease or flammable material accumulate in or near the range. - Failure to do so can result in serious burns.

• Read all instructions contained in these installation

instructions before installing range. • Remove all packing materials from the oven compartments before connecting the electrical supply to the range. • Observe all governing codes and ordinances. • Be sure to leave these instructions with the consumer. NOTE Keep these instructions with your owner’s manual for future reference. • As when using any appliance generating heat, there are certain safety precautions you should follow. • Be sure your range is installed and grounded properly by a qualified installer or service technician. • Make sure the wall coverings around the range can withstand the heat generated by the range. • To eliminate the need to reach over the surface elements, cabinet storage space above the elements should be avoided. TOOLS NEEDED Gloves Safety Glasses Tape Measure Pencil Gloves Safety Glasses Tape Measure Pencil Gloves Safety Glasses Tape Measure Pencil PREPARE TO INSTALL THE RANGE PARTS NOT PROVIDED WARNING • The information in this manual should be followed exactly. - A fire or electrical shock may result causing property damage, personal injury or death. Gloves Safety Glasses Tape Measure Pencil CAUTION • You should put on gloves during the installation procedure. - Failure to do so can result in bodily injury. Gloves Safety Glasses Tape Measure Pencil WARNING • Any person should not step or sit on the oven door. You should install the Anti-Tip Bracket supplied with the range. - The range could be tipped and injury might result from spilled hot liquid, food, or the range itself. - If the range is pulled away from the wall for cleaning, service, or any other reason, ensure that the Anti-Tip Device is properly reengaged when the range is pushed back against the wall. Gloves Safety Glasses Tape Measure Pencil Gloves Safety Glasses Tape Measure Pencil (For Anti-Tip Bracket Mounted on Concrete Floors and Walls)

PREPARE TO INSTALL THE RANGE

Part 2 INSTALLATION DRAWINGS (LDE Series only) NOTE SAVE FOR THE USE OF THE LOCAL ELECTRICAL INSPECTOR. CLEARANCES AND DIMENSIONS (Figure 1) To install range refer to the following Figure 1. For installation in CANADA, a Free-standing range is not to be installed closer than 15/32 (12mm) from any adjacent surface. MINIMUM DIMENSIONS (Figure 2) * 30”(76.2 cm) minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet; or 24”(60.9 cm) minimum when bottom of wood or metal cabinet is protected by not less than 1/4”(6.4 cm) flame retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015”(0.381 mm) stainless steel, 0.024”(0.610 mm) aluminum or 0.020”(0.508 mm) copper. ** 15”(38.1 cm) minimum between countertop and adjacent cabinet bottom. 2.5” (6.3cm) 6” (15.2cm) 9” (23cm) 9” (23cm) 11”(28cm) 15”(38cm) 4” (10cm) 4” (10cm) 5” (13cm) Wall Center Cabinet Cabinet opening 2.5”(6.3cm) 2.5”(6.3cm) 6” (15.2cm) 6” (15.2cm) FIGURE 1 FIGURE 2 A = 30”(76.2 cm) For U.S.A = 30”(76.2 cm) ~ 31”(78.7 cm) For CANADA CAUTION • You should make sure that the wall covering, countertop and cabinets around the range can withstand the heat (up to 194°F) generated by the range. - Discoloration, delamination or melting may occur. - This range has been designed to comply with the maximum allowable wood cabinet temperatures of 194°F. Gloves Safety Glasses Tape Measure Pencil CAUTION • Cabinet storage space located above the surface units should be avoided. • You should install a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets. If cabinet Storage is to be provided. - The risk of burns or fire by reaching over the heated surface elements can be reduced. WARNING • You should use two or more people to move and install range. (Excessive Weight Hazard) - Failure to do so can result in back or other injury. • You never pull or push any handles of upper & lower door to move and install range. - Failure to do so can result in serious damage to the door of the range. 2

The Cord/Conduit connection plate is used for the

installation of power cord or conduit. For power cord, install it with the connection plate as INSTALLED. For conduit, remove the connection plate located below the rear of the drawer body and use the conduit hole (11/8”) instead of power cord hole (13/8”). (Refer to Figure 5 and 6.) 3, 4 - Wire electrical wall Receptacle CONNECT RANGE CORD The Rear Access cover must be removed. Loosen the three screws with a screwdriver. The terminal block will then be accessible. Protection cover FIGURE 3 FIGURE 4 Range rating, watts Specified rating of power-supply- cord kit, amperes 120/240 volts 3-wire 8,750 - 16,500 16,501 - 22,500 120/208 volts 3-wire 7,801 - 12,500 12,501 - 18,500 40 or 50A 50 Diameter (inches) of Range connection Opening Conduit 11/8” 13/8” Power cord 13/8” 13/4” Specified power-supply-cord kit rating ELECTRICAL CONNECTION REQUIREMENTS This appliance must be installed and grounded on a branch circuit by a qualified technician in accordance with the National Electrical code ANSI/NFPA NO. 70 - latest edition. All wiring should conform to Local and NEC. This range requires a single-phase, 3 wire, A.C 120/208V or 120/240V 60Hz electrical system. Use only a 3-conductor or a 4-conductor UL-listed range cord with closed-loop terminals, open-end spade lugs with upturned ends or similar termination. DO NOT install the power cord without a strain relief. A range cord rated at 40 amps with 120/240 minimum volt range is required. If a 50 amp range cord is used, it should be marked for use with 13⁄8” diameter connection openings. This appliance may be connected by means of conduit or power cord. If conduit is being used, go to page 7 for 3 wire conduit connections or page 8 for 4 wire conduit connections. WARNING • New branch-circuit installations (1996 NEC) for mobile homes, recreational vehicles, and installations where local codes do not allow grounding through the neutral wire require a 4-conductor UL listed range cord or 4 wire conduit connection. • Power supply cord and plug should not be modified. If it will not fit the outlet, have a proper outlet Installed by a qualified electrician. • Using an extension cord to connect the power is prohibited. The way to connect the power cord and plug directly is strongly recommended. • Electrical ground is required on this appliance. • You should make sure that the power cord is not pinched by the range or heavy objects. - Failure to do so can result in serious burns or electrical shock. Gloves Safety Glasses Tape Measure Pencil Protection cover FIGURE 5 FIGURE 6 Remove the Conduit connection plate Assemble the strain relief hole Reinstall the Cord/Conduit connection plate WARNING • You never remove the protection cover covering the rear of lower oven. - Failure to do so can result in serious damage to power cord. The damage causes serious burns and electric shock. 4 Wire receptacle (14-50R) 3 Wire receptacle (10-50R) 3 4

Assemble the strain relief

to the 1 3/8” opening in Conduit connection plate Separate Strain Relief before installation 3-wire connection with a power supply cord WARNING • The middle (neutral or ground) wire of a 3 wire power cord or a 3 wire conduit has to be connected to the middle post of the main terminal block. The remaining two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block. - Failure to do so can result in electrical shock, severe personal injury or death. Gloves Safety Glasses Tape Measure Pencil Install the power cord as follows: For power cord installations, Hook the strain relief over the power cord hole (13/8”) located below the rear of lower oven. Insert the power cord through the strain relief and tighten it. (Refer to Figure 7.) DO NOT install the power cord without a strain relief. 1. Remove the lower 3 screws from the terminal block and retain them. (Refer to Figure 8.) 2. Insert the 3 screws through each power cord terminal ring and into the lower terminals of the terminal block. Make sure that the center wire (white/neutral) is connected to the center lower position of the terminal block. 3. Tighten 3 screws securely into the terminal block. Do not remove the ground strap connections. 4. Go to page 10.

Follow the instructions under “ 4 CONNECT RANGE

CORD” on page 5 to correctly install the strain relief. 1. Remove the lower 3 screws from the terminal block and retain them. (Refer to Figure 9.) Remove the ground screw and retain it. 2. Remove ground strap and discard as shown in Figure 9. Do not discard any screws. 3. Insert the ground screw into the power cord ground wire terminal ring and secure it to the range frame. 4. Insert the 3 screws through each power cord terminal ring and into the lower terminals of the terminal block. Make sure that the center wire (white/neutral) is connected to the center lower position of the terminal block. Tighten 3 screws securely into the terminal block. 5. Go to page 10. Install the conduit as follows: Remove the Conduit connection plate from the rear of lower oven and rotate it as shown in Figure 5. The conduit hole (11/8”) must be used. First, prepare the conduit wires as shown in Figure 10. Second, install conduit as shown in Figure 6. For conduit installations, after purchasing a strain relief, insert it in the conduit hole (11/8”). Then install the conduit through the body of strain relief and fasten the strain relief with its ring. Reinstall the bracket. For conduit connections : If the wire in the conduit is copper it must be 8 or 10 AWG wiring. If the wire in the conduit is aluminum it must be 6 or 8 AWG wiring. 1. Loosen the lower 3 screws from the terminal block. (Refer to Figure 11.) 2. Insert the bare wire (white/neutral) end through the center terminal block opening. Do not remove ground strap connections. 3. Insert the two side bare wire ends into the lower left and the lower right terminal block opening. Tighten the 3 screws securely into the terminal block. (approximately 35 - 50 IN-LB) 4. Go to page 10. FIGURE 10 or 3 wire 4 wire FIGURE 9 4-wire connection WARNING • Only a 4-conductor power-supply cord kit rated 120/240 volts, 50 amperes and marked for use with ranges with closed- loop connectors or open-end spade lugs with upturned ends shall be used. The middle (neutral) wire of the power cord or 4-wire conduit has to be connected to the middle post of the main terminal block. The other two wires of the power cord or conduit have to be connected to the outside posts of the main terminal connection block. The 4th ground wire must be connected to the frame of the range with the ground screw. - Failure to do so can result in electrical shock, severe personal injury or death. Gloves Safety Glasses Tape Measure Pencil FIGURE 11 3-wire connection 4-wire connection with a power supply cord 3-wire connection: conduit

4-wire connection: conduit

1. Follow the instructions under “Install the conduit as follows” on page 7 to correctly install the strain relief. DO NOT install the conduit without a strain relief. 2. Loosen the 2 lower left and right screws from the terminal block. (Refer to Figure 12.) Remove the lower 2 center screws. 3. Remove ground strap and discard as shown in Figure 12. Do not discard any screws. 4. Attach the ground bare wire end to range frame and secure it in place with the ground screw (Refer to figure 12.) 5. Insert the bare wire (white/neutral) end through the center terminal block opening. 6. Insert the two side bare wire ends into the left and the right terminal block opening. Tighten the 3 screws securely into the terminal block. (approximately 35 - 50 IN-LB) 7. Go to page 10. FIGURE 12 4-wire connection

INSTALL THE RANGE

Replace the access cover on the back of the range. To replace the wire cover, insert the two tabs into the openings located below the opening and tighten the three screws. ANTI-TIP DEVICE INSTALLATION 1. Locate the bracket using the template An Anti-tip bracket is packaged with template. The instructions include necessary information to complete the installation. Read and follow range installation instruction sheet (template). 2. Level the range Level the range by adjusting the leveling legs with a wrench. Use a level to check your adjustments. Place the level diagonally on the oven rack, and check each direction for level. First check direction 1 . After check direction 2 . If the level doesn’t show level on the rack, adjust the leveling legs with a wrench. FINAL INSTALLATION • Move range close enough to the opening to plug into the receptacle. • Slide range into position insuring that the left back leg slides under the anti-tip bracket. Range should sit flush against the back wall when properly installed. • Carefully attempt to tip range forward to insure that the anti-tip bracket is engaged properly. If properly installed, the anti-bracket will prevent the range from being tipped. If the range can be tipped, reinstall the range until the bracket is properly installed and the range will not tip forward. • Turn on electrical power. Check the range for proper operation as described in owner’s manual. WARNING • Any person should not step or sit on oven door. You should install the Anti- Tip Bracket supplied with the range. - The range could be tipped and injury might result from spilled hot liquid, food, or the range itself. - If the range is pulled away from the wall for cleaning, service, or any other reason, ensure that the Anti-Tip Device is properly reengaged when the range is pushed back against the wall. Gloves Safety Glasses Tape Measure Pencil Gloves Safety Glasses Tape Measure Pencil 5 6

Printed in Mexico

www.lg.com Register your product Online! LG Customer Information Center 1-800-243-0000 1-888-865-3026 1-888-542-2623 USA, Consumer User USA, Commercial User CANADA

Other Oven Manuals