Lifebreath 195TRV Features And Benefits

Text of the manual

F E A T U R E S

A N D B E N E F I T S W W W . L I F E B R E A T H . C O M Today’s homes require controlled ventilation to improve the Indoor Air Quality and maximize energy efficiency. The TRV is specifically designed for moderate/ temperate geographies with winter temperatures below freezing and summer conditions that are hot and humid. (Typically >75°F and 65% R.H.) The TRV is a new concept in ventilation that provides the compounded benefits of moisture transfer with unmatched heat recovery in a single unit. This new configuration is the only way to ensure year round temperature and moisture transfer. TRV TOTAL RECOVERY VENTILATOR • ASHRAE 62.2 Ventilation Standards • Sensible and Latent transfer for all 12 months • Adjustable ventilation rates with ControlAir 15 - 5 selectable speeds • Automatic damper defrost • Intermittent operation

Digital Electronic Timer - 20/40/60 min.

99-350 Lifestyles Ventilation Control includes Programmable Time Clock and Dehumidistat 99-109 Air Sentry™ Air Quality Monitor designed to accept remotely mounted Control Pad 99-250 Ventilation Dehumidistat - Dehumidistat designed to accept remotely mounted Control Pad. 99-160 Duct Heater w/ Electronic SCR Thermostat, 1 Kw, 7” (178 mm) 99-161 Duct Heater w/ Electronic SCR Thermostat, 2 Kw, 7” (178 mm) 99-186 Weatherhoods, Two - 6” (150 mm) c/w 1/4” (6mm) mesh screen WARRANTY Units carry a LIFETIME warranty on the heat recovery core, a five year warranty on the ERV core and a 5 year replacement parts warranty. TRV Sales Sheet Revised: 06/07 Total Recovery Ventilator Model 195TRV/300TRV 49�" (1245) STALE�AIR TO�OUTSIDE FRESH�AIR TO�INSIDE 14�3/4" (375) 19" (483) Ports� 7"�(178�mm) CONDENSATE� DRAINS BLOWERS *NOTE:� �Front�clearance� �of�25�inches�(635�mm)� �is�recommended� �for�servicing�unit.� MOTOR FRESH�AIR FROM�OUTSIDE STALE�AIR FROM�INSIDE �DEFROST DAMPER DEFROST�AIR FROM�INSIDE Ports� 6"�(150�mm) METAL�CLASPS HRV Core ERV Core ENGINEERING DATA MOTORS AND BLOWERS - Each air stream has one centrifugal blower driven by a common PSC motor. 5 speed fan operation. 120 VAC, 1.5 Amps. FILTERS - Washable air filters in exhaust and supply air streams. MOUNTING THE TRV - Four threaded inserts at corners of case designed to accept four reinforced polyester straps that are supplied with the unit. DEFROST - Damper defrost system. DEHUMIDISTAT - Adjustable Internal Dehumidistat. CASE - Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance. Insulated to prevent exterior condensation. Drain connections 2 - 1/2" (12 mm) OD. CONTROLS - ControlAir 15 - Standby/ON mode, 20 ON/ 40 OFF mode, Recirculation mode (on compatible units), (each mode has 5 speeds). Control pad can be removed from HRV and remotely mounted. WEIGHT 106 lbs. (48 kg) SHIPPING WEIGHT 108 lbs. (49 kg) 195DCS FANCURVE 225 175 200 100 75 125 150 50 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Air Flow (cfm) Static Pressure (in H20) HIGH SPEED* MEDIUM HIGH SPEED MEDIUM SPEED MEDIUM LOW SPEED LOW SPEED 4 5 3 2 1 4 3 2 1 5 All units conform to CSA and UL standards. DIMENSIONS 195TRV/300TRV inches (mm) PERFORMANCE Net supply airflow in cfm (L/s) against external static pressure 195TRV 300TRV E.S.P cfm L/s cfm L/s @ 0.1” (25 Pa) 203 (96) 265 (125) @ 0.2” (50 Pa) 191 (90) 260 (123) @ 0.3” (75 Pa) 182 (86) 250 (118) @ 0.4” (100 Pa) 167 (79) 235 (111) @ 0.5” (125 Pa) 155 (73) 220 (104) VAC @ 60HZ 120 120 WATTS / Low speed 100 150 WATTS / High speed 173 333 Amp rating 1.5 2.9 300DCS FANCURVE 300 275 250 225 200 175 150 125 100 75 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Air Flow (cfm) Static Pressure (inH20) HIGH SPEED* MEDIUM HIGH SPEED MEDIUM SPEED MEDIUM LOW SPEED LOW SPEED 4 5 3 2 1 4 3 2 1 5 *Manufacturers Data 195TRV 300TRV

Other Ventilation Hood Manuals