Lightolier IC Series Specification
Read Online
Read the Lightolier IC Series Specification online using the built-in PDF viewer.
Text of the manual
Louver IC Series
Page 1 of 2
2' x 4' Recessed Fluorescent, 3" 12, 18, 24 or 32 Cell Parabolic Louver
Static, 2,3 or 4 Lamp, T8
• UL Listed Type IC Recessed Luminaire
(Intended for Direct Thermal Insulation Contact).
• Construction provides optimum thermal performance.
• Ballast mounted with thermal heat sink.
• Ideal for fire rated ceilings.
• One piece housing.
• Black exterior for cooler ballast operating temperature.
• 5" deep body.
• 77.7% efficient (3 light 18 cell)
• Hemmed over side rails for maximum safety.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips.
• Pre-anodized aluminum parabolic louver.
• Spring loaded rooster head latches.
• 18 gauge steel hinges.
• Louver has protective film dust guard.
• Vertical grain louver eliminates reflected lamp images on cross baffle.
• Construction to meet NYC Code or Chicago Plenum requirements
is available.
Mounting Methods
Dimensions
G
exposed T-grid ceiling.
T
exposed slot T-grid ceiling.
drywall kit.
1/4" max.
15/16"
or 1"
24"
Type “G”
Fixture
Support
(by others)
Drywall Kit
(See Options)
Drywall
(by others)
9/16"
24"
1-1/2" max.
1-7/8" max.
Order Catalog Number: FK92X4.
24" (610mm)
5"
(127mm)
6"
(152mm)
Air supply slots
(DPA only)
47-31/32" (1218mm)
2" x 2-1/2" access plate
with two K.O.s
(7/8" dia.)
3" Nominal
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
08/10
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group
Section 7/Folio Q80-25 Rev. A
Louver IC Series
Page 2 of 2
2' x 4' Recessed Fluorescent, 3" 12, 18, 24 or 32 Cell Parabolic Louver
Static, 2,3 or 4 Lamp, T8
Options/Accessories
Plaster Frame: Catalog Number: PF24.
Radio Interference Filter: To order one RIF per fixture; SUFFIX: R.
To order one RIF per ballast; SUFFIX: B.
Fusing: Internal fast-blow fusing. SUFFIX A. Internal slow-blow fusing. SUFFIX C.
Electrical Wiring Options: Consult factory.
Drywall Kit: Order Catalog Number: FK92X4. (Request Folio OA30-10 Rev. A).
Chicago Plenum: SUFFIX: C.
Specifications
Performance: In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1,
reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .85. To prevent
glare the VCP shall be not less than 75 either lengthwise or crosswise (at 100fc level) and
the average brightness at 65° shall not exceed 1606 candelas per square meter. To control
veiling reflections, luminaire output in the 30°-90° zone shall not be less than 72.0%.
Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing is ribbed for
rigidity with side rails hemmed over and housing ends turned-in for safe handling.
Specifications (continued)
Louver is pre-anodized aluminum.
Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester enamel
minimum 86% reflectance. Rust preventative undercoating. Louver–low iridescence semi-specular
anodized vertical grain aluminum reflector sheet is standard.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
Labels: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See:
www.lamprecycle.org
SECTION 7/Folio Q80-25
IC Series:
Recessed
Parabolic
suitable for
Thermal
Insulation
Contact
S
Body Style:
S=Static
2
Fixture
Width
Lamp
Quantity
2=2 lamps
3=3 lamps
4=4 lamps
Ballast Type:
<20THD <10THD
1 & 2 Lamp Elec. T8
SO *
HI *
1-3 Lamp Elec. T8
03 *
H3 *
1-4 Lamp Elec. T8
04 *
H4 *
†*Instant Start Standard
††Instant Start (120, 277 or UNV)
††Program Rapid Start (UNV only)
NOTE:
For T8 UNV, you must use HI Ballast Code.
Ordering Information
Explanation of Catalog Number. Example: ICS2G12LS232120UNVHI
Ceiling Type:
G= Grid
(lay-in T bar)
T= Slot grid
Number of
Cells:
12=2 rows
of 6
18=3 rows
of 6
24=3 rows
of 8
32=4 rows
of 8
Louver Finish:
L = Low iridescence
Semi-specular
(standard)
P =Low iridescence
Specular
W =White Baked
Enamel
S
Single "V"
Reflector
Voltage:
120, 277 or
UNV=120-277
Lamp Type/
Fixture Length:
32=32W T8
(Nominal 48")
IC
Standard IC Parabolic
IY
For NYC Code – I.B.E.W. Manufactured
0.0
45.0
90.0
FLUX
0
1571
1571
1571
5
1572
1569
1573
150
15
1511
1547
1579
438
25
1399
1489
1585
689
35
1242
1411
1593
888
45
1033
1330
1777
1057
55
744
1158
1217
939
65
274
415
322
356
75
17
30
38
42
85
1
1
1
2
90
0
0
0
Model No. ICS2G12LS232120SO
LER = FP - 65.5
IW - 61.6
BF - 0.87
Comparative yearly lighting energy cost per
1000 lumens = $3.67
Report Number: ITL49787
Catalog Number: ICS2G12LS232120S0
Lamp: (2) F32 T8
Luminaire: IC 2' X 4' Troffer with 2X6
Semi-Specular Louver
Ballast: M3-RN-T81LL-D-120
Report is based on 2850 Lumens per lamp.
Efficiency: 80.0%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.3
1.6
Shielding Angles:
25
29
Plane:
0-Deg
90-Deg
Luminous Length:
45.125
21.000
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
2389.
3075.
4109.
55
2121.
3301.
3469.
65
1060.
1606.
1246.
75
107.
190.
240.
85
19.
19.
19.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
1
89 85 83 80 78 76 77 75 74
2
81 76 71 71 68 64 69 66 63
3
74 67 61 63 59 55 61 57 54
4
68 59 53 56 51 47 55 50 46
5
63 53 46 50 45 40 49 44 40
6
58 48 41 45 40 35 44 39 35
7
53 43 36 41 35 31 40 35 31
8
50 39 32 37 32 28 36 31 27
9
46 36 29 34 29 25 33 28 25
10 43 33 27 32 26 22 31 26 22
ZONE
LUMENS % LAMP
% FIXT
00-030
1277
22.4
28.0
00-040
2165
38.0
47.5
00-060
4161
73.0
91.2
00-090
4561
80.0
100.0
90-180
0000
0.0
000.0
00-180
4561
80.0
100.0
ZONAL LUMEN SUMMARY
Mounting Height
Lengthwise
Crosswise
Room
Luminaires
Luminaires
Size
0 Deg Plane
90 Deg Plane
8.5 10 13 16
8.5 10 13 16
30x30
86 81 75 73
84 77 71 71
40x40
86 85 80 74
84 81 76 71
60x30
86 84 79 75
84 79 76 74
60x60
86 85 84 78
84 80 80 75
100x100
86 85 84 81
84 80 80 77
TYPICAL V.C.P.'s
0.0
45.0
90.0
FLUX
0
2502
2502
2502
5
2497
2501
2500
239
15
2395
2482
2549
702
25
2213
2422
2674
1128
35
1966
2388
2741
1484
45
1647
2183
2047
1541
55
1202
1300
970
1062
65
483
419
384
444
75
23
25
20
31
85
3
3
3
5
90
0
0
0
Model No. ICS2G18LS33212003
LER = FP - 68.8
IW - 85.8
BF - 0.89
Comparative yearly lighting energy cost per
1000 lumens = $3.49
Report Number: ITL49576
Catalog Number: ICS2G18LS33212003
Lamp: (3) F32 T8
Luminaire: IC 2' X 4' Troffer with 3X6
Semi-Specular Louver
Ballast: M3-RN-T81LL-120
Report is based on 2850 Lumens per lamp.
Efficiency: 77.6%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.6
Shielding Angles:
18
38
Plane:
0-Deg
90-Deg
Luminous Length:
45.125
21.000
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
3808.
5048.
4733.
55
3427.
3706.
2765.
65
1869.
1621.
1486.
75
145.
158.
126.
85
56.
56.
56.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.200
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
1
86 83 81 78 76 75 75 74 72
2
80 74 70 70 67 64 68 65 62
3
73 66 61 63 58 55 61 57 54
4
67 59 53 56 51 47 54 50 47
5
62 53 47 51 45 41 49 45 41
6
57 48 41 46 40 36 45 40 36
7
53 43 37 42 36 32 41 36 32
8
50 40 33 38 33 29 37 32 29
9
46 36 30 35 30 26 34 29 26
10 43 33 28 32 27 23 32 27 23
ZONE
LUMENS % LAMP
% FIXT
00-030
2068
24.2
31.2
00-040
3552
41.5
53.5
00-060
6155
72.0
92.8
00-090
6634
77.6
100.0
90-180
0000
0.0
000.0
00-180
6634
77.6
100.0
ZONAL LUMEN SUMMARY
Mounting Height
Lengthwise
Crosswise
Room
Luminaires
Luminaires
Size
0 Deg Plane
90 Deg Plane
8.5 10 13 16
8.5 10 13 16
30x30
83 77 69 65
85 80 74 69
40x40
85 80 76 68
85 82 79 71
60x30
83 78 74 69
85 81 78 71
60x60
85 81 81 73
85 82 83 76
100x100
85 81 81 75
85 82 83 77
TYPICAL V.C.P.'s
Options:
Lamps
Flex
EM Pack
Fuse
(Consult your
representative)
-
Job Information
Type:
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
08/10
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group
Section 7/Folio Q80-25 Rev. A