NOTE: Drawing is not to scale.

SPECIFICATION SHEETS 010706 Product Dimensions Large Capacity Vented Dryers Flat Controls T1312 2" 23 1/2" 33 3/8" - 34 1/8" 22 1/2" 3 3/4" - 4 1/2" V Notes • All installations must be done in accordance with local codes • See "Cut-out Dimensions" sheet for undercounter or built-in space requirements • Optional Easy Installation Kits utilize existing 208-240 Volt - 30 Amp line to connect two Miele machines without rewiring . E - V- 5 foot - 208-240 Volt - 15 Amp 4-wire (2 live / neutral / ground) molded plug power supply connects upper right rear (NEMA 14-30 Configuration). Venting location may be adjusted to lower right or left side or lower left rear (see separate sheet). Location Codes E

NOTE: Drawing is not to scale.

SPECIFICATION SHEETS 010706 Product Dimensions Large Capacity Vented Dryer Angled control T1313 2" 23 1/2" 33 3/8" - 34 1/8" 22 1/2" 3 3/4" - 4 1/2" 21 1/2" V Notes • All installations must be done in accordance with local codes • See "Cut-out Dimensions" sheet for undercounter or built-in space requirements • Optional Easy Installation Kits utilize existing 208-240 Volt - 30 Amp line to connect two Miele machines without rewiring. E - V- 5 foot - 208-240 Volt - 15 Amp 4-wire (2 live / neutral / ground) molded plug power supply connects upper right rear (NEMA 14-30 Configuration). Venting location may be adjusted to lower right or left side or lower left rear (see separate sheet). Location Codes E

NOTE: Drawing is not to scale.

SPECIFICATION SHEETS 010706 Product Dimensions Large Capacity Condenser Dryers Flat Controls T1332C 2" 23 1/2" 33 3/8" - 34 1/8" 22 1/2" 3 3/4" - 4 1/2" Notes • All installations must be done in accordance with local codes • See "Cut-out Dimensions" sheet for undercounter or built-in space requirements • Optional Easy Installation Kits utilize existing 208-240 Volt - 30 Amp line to connect two Miele machines without rewiring. E - D - CD - 5 foot - 208-240 Volt - 15 Amp 4-wire (2 live / neutral / ground) molded plug power supply connects upper right rear (NEMA 14-30 Configuration). Drain location Removable drawer if drain connection is not utilized Location Codes CD D E

NOTE: Drawing is not to scale.

SPECIFICATION SHEETS 010706 Product Dimensions Large Capacity Condeser Dryer Angled control T1333C 2" 23 1/2" 33 3/8" - 34 1/8" 22 1/2" 3 3/4" - 4 1/2" 21 1/2" Notes • All installations must be done in accordance with local codes • See "Cut-out Dimensions" sheet for undercounter or built-in space requirements • Optional Easy Installation Kits utilize existing 208-240 Volt - 30 Amp line to connect two Miele machines without rewiring. E - D - CD - 5 foot - 208-240 Volt - 15 Amp 4-wire (2 live / neutral / ground) molded plug power supply connects upper right rear (NEMA 14-30 Configuration). Drain location Removable drawer if drain connection is not utilized Location Codes CD D E

NOTE: Drawing is not to scale.

SPECIFICATION SHEETS 010706 Product Dimensions Large Capacity Condenser Dryers Flat Controls - Decor unit T1339C CD 2" 23 1/2" 33 3/8" - 34 1/8" 22 1/2" 5 7/8" 3 3/4" - 4 1/2" 1 1/2" Notes • All installations must be done in accordance with local codes • See "Cut-out Dimensions" sheet for undercounter or built-in space requirements • Optional Easy Installation Kits utilize existing 208-240 Volt - 30 Amp line to connect two Miele machines without rewiring. E - D - CD - 5 foot - 208-240 Volt - 15 Amp 4-wire (2 live / neutral / ground) molded plug power supply connects upper right rear (NEMA 14-30 Configuration). Drain location Removable drawer if drain connection is not utilized Location Codes D E

NOTE: Drawing is not to scale.

SPECIFICATION SHEETS 010706 Cut-out Dimensions Built-in Installations Large Capacity Laundry Products 24" See Notes Water & Electrical Connection Location C 32 3/8" - 35 1/4" • Needed depth will vary by model number: T1302,T1303,T1322C,T1323C: 24" minimum T1329C: 25" minimum • Typically requires removal of unit's lid. Out of box unit height dimension without lid is 32 5/16" - 32 11/16". Notes Location Codes C - Cutout for Electric and Vent or Drain pass-through. Adjust according to duct or drain location.

NOTE: Drawing is not to scale.

SPECIFICATION SHEETS 010706 5 1/2" 4" 7 1/2" Existing 208 / 240 Volt 30 Amp Product Dimensions Easy Installation Kits 057B / 060B Notes • Connect Washer and Dryer to Easy Installation Kit • All installations must be done in accordance with local codes • 057B Kit fitted with a NEMA10-30 Plug • 060B Kit fitted with a NEMA14-30 Plug

NOTE: Drawing is not to scale.

SPECIFICATION SHEETS 010706 Product Dimensions Laundry Stand WTS420 - White Only 26" 11" Notes • For use with both large and super capacity washers or tumble dryers. • All installations must be done in accordnace with local codes 23 3/8"

NOTE: Drawing is not to scale.

SPECIFICATION SHEETS 010706 Product Dimensions Stacked Washer & Dryer Example Combination W1113 + T1313 2" D W E 3 3/4" - 4 1/2" 23 1/2" 22 1/2" 66 3/8" - 67 1/8" V D - E - W - V- 5 foot flexible drain hose connects upper left rear. 208-240 Volt - 15 Amp 5 foot 4-wire (2 live / neutral / ground) molded plug power supply connects upper right rear. 5 foot separate flexible hot and cold water intake hoses connect upper left rear. Venting location may be adjusted to lower right or left side or lower left rear (see separate sheet). Location Codes Notes • All installations must be done in accordance with local codes • See "Cut-out Dimensions" sheet for undercounter or built-in space requirements • Optional Easy Installation Kits utilize existing 208-240 Volt - 30 Amp line to connect two Miele machines without rewiring. • Remove transport struts in rear of washing machine before installation. D E

NOTE: Drawing is not to scale.

SPECIFICATION SHEETS 010706 Panel Information Integrated Laundry T1339C Decor Unit These units come equipped with a full size white front panel. These units are also designed to either accept a thin insert or a custom front panel supplied by the custom cabinet maker. Sizes are as follows: Version 1 - Thin insert Width: 23 1/4" for all machines Thickness: up to 1/8" Height: 25" in all cases With this version, a thin white frame will be exposed after installation Version 2 - Custom Front Panel Width: 23 3/8" for all machines Thickness: up to 3/4" Height: Up to 25" With this version, the existing front panel is removed and replaced by the new custom panel Miele Decor Laundry unit Hinge Notches In certain installations, notches will be required to accomodate the hinges in the front panel. Miele Decor Laundry Control Panel To center lines 16 3/4" Notch Pattern For this installation, drill the following pattern in the appropriate locations. Note: To insure access to customer servicable features, a minimum 4" toe kick above finished floor (AFF) is required. 3 7/8" C C C 1 1/8" 7/8" 1/4" Ø 1/4" Ø 1" 1" Drill all holes to a 5/8" depth 1 3/8" Ø

Left Side View

Right Side View 4 3/4" 3 7/8" 4 3/4" 3 1/2" - 4 1/4" 3 1/2" - 4 1/4" 3 1/2" - 4 1/4" Vent Locations Vent Duct Calculations Maximum Duct Lengths 4" diameter 65 feet 4 3/16" diameter 98 feet 4 3/4" diameter 140 feet 5" diameter 196 feet Type of Bend or duct Effective Radius Subtract Flexible duct 90° 4 - 12 inches 1 3/4 feet Flexible duct 90° 12 - 20 inches 1 1/4 feet Flexible duct 45° 4 - 20 inches 1 1/4 feet Smooth duct 90° or 45° 4 - 8 inches 1 1/4 feet Elbow 90° Sharp bend 8 1/4 feet Concertina bend 8 inch 2 3/4 feet Segmented bend 8 inch 2 feet Louvered wall or window vent (#03780400) 12 1/2 feet Wall vent kit with flap (#00087184) 5 feet Window vent kit with flap (#00087185) 5 feet Exhaust connection - left 20 feet Exhaust connection - right 33 feet Flat duct (#01221330) 59 feet DO NOT use vinyl ducting with Miele appliances. Corresponding Dryer Height with NO lid: 32 1/8" - 32 7/8" Corresponding Dryer Height with lid: 33 3/8" - 34 1/8"

Stacked Washer & Dryer

Example Combination Rear View Left Side View Right Side View Vent Locations Corresponding Total Height with lid: 66 3/8" - 67 1/8" 4 3/4" 36 3/8" - 37 1/8" Stacking Kit Stacking Kit 36 3/8" - 37 1/8" 3 7/8" 4 3/4" Stacking Kit 36 3/8" - 37 1/8"