Waterproof Weighing scale

ESW © Excell Precision Limited 2014. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorized by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied.

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 Table of Content INSTRUCTION FOR USE ...................................................................................................2 PREPARING TO USE THE SCALE.....................................................................................2 CHAPTER 1 INTRODUCTION ............................................................................................4 1-1 FEATURES AND SPECIFICATIONS.....................................................................................4 1-2 POWER SUPPLY............................................................................................................5 1-3 PANEL AND KEYBOARD INTRODUCTION ...........................................................................5 1-4 OPERATING THE SCALE .................................................................................................6 1-5 SELF-TEST MODE.........................................................................................................7 1-6 ERROR MESSAGES .......................................................................................................8 1-7 WEIGHT UNIT ...............................................................................................................8 CHAPTER 2 ADVANCED FUNCTIONS ..............................................................................9 2-1 ADVANCED FUNCTION SETTING TABLE............................................................................9 2-2 ADVANCED FUNCTION SETTING WORKFLOW .................................................................10 2-3 GENERAL FUNCTION SETTING ..............................................................11 2-3-1 Automatic Backlight Function Setting .......................................12 2-3-2 Automatic Power-off Timer Setting ...........................................13 2-3-3 Hi/Lo/OK Function Setting ........................................................14 2-3-4 Restore to the Default Setting ...................................................15 2-3-5 Noise Filter Setting ...................................................................16 2-3-6 Hold Function Setting ..............................................................17 2-3-7 Auto Unit Weight Averaging Setting ........................................18 2-4 WEIGHT CALIBRATION ..............................................................................19 APPENDIX 1 7-SEGMENT DISPLAY CHARACTERS ......................................................20

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 Instruction for Use 1. Please keep the scale in a cool dry place. Do not store it at high temperature. 2. Avoid objects impacting with the scale. Do not drop loads onto the scale or subject the weigh pan to any strong shock loads. 3. The load placed on the weigh pan must not exceed the maximum weighing capacity of the scale. 4. If the scale is not going to be used for some time, please clean it and store it in a plastic bag in dry conditions. A desiccant sachet may be included to prevent any moisture build up. Preparing To Use the Scale 1. Adjust the four levelling feet (if fitted) to set the scale pan level using the spirit level bubble located at the front of the scale. 2. Avoid operating the scale in direct sunlight or drafts of any kind. 3. If possible avoid connecting the scale to ac power outlet sockets which are adjacent to other appliances to minimise the possibility of interference affecting the performance of the scale. 4. Remove any weight that might be on the weigh pan before the scale is switched on and avoid leaving weight on the pan for long periods of time 5. All goods weighed should be placed in the centre of the weigh pan for accurate weighing. The overall dimensions of the goods being weighed should not exceed the dimension of the weigh pan. 6. We suggest to warm up the scale for 15~20 minutes before operation to ensure best accuracy. 7. Please note when the symbol keeps flashing on the screen, the batteries need to be replaced. 8. Introduction of Storage Battery Thank you for purchasing EXCELL waterproof weighing scale. In order to use the scale properly, please read this instruction carefully before use. If you have a problem concerning the scale, please contact your supplier.

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 Due to the storage battery adopt the advanced free-maintaining technique, customers need not to replenish electrolyte. The scale should be recharged every 3 months to prevent failure of the internal rechargeable battery. 1. The battery should be charged for 8~10 hours. 2. The temperature of battery should below 45℃. Maintaining 1. Please do not discharge with over-current when using the battery. Please charge the battery after discharging current. 2. Please take down the battery when the scale is not used for a long time or break the connection of cathode. 3. Do not short the battery terminals to check whether there is current. Please check whether the connection point is firm to guarantee good connection. 4. The battery should be replaced by specialized person. No reverse-battery or the product will be damaged. a) Anode of battery should be connected with Anode of product battery(usually red cable) b) Cathode of battery should be connected with Cathode of product battery (usually brown cable or black cable) c) See the picture following Safety warnings 1. The electrolyte of battery is caustic which causes metal, cotton, etc to corrode. 2. The hydrogen will be resolved when using or charging the battery and it will cause explosion when approaches fire. Brown cable(or black cable) connected with Anode of battery Red cable connected with Cathode of battery

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 Chapter 1 Introduction 1-1 Features and Specifications Features: ‹ Sealed waterproof silica gel strip blocks water from infiltrating into the scale. ‹ Surrounded by waterproof grade sheeting to ensure the water free. ‹ 1/3,000~1/6,000 display resolution available. ‹ Aluminum frames coated with anti-corrosion treatment for longer lifespan. ‹ Stainless steel made feet and platter for anti-rust. ‹ High speed of 24bits AD fast reacts and shortens the weighing operation duration. ‹ Selectable units: Kilogram (kg), gram (g), ounce (oz), and pound (lb) weighing units available. ‹ Built-in rechargeable battery can be easily replaced. ‹ Low power indication and auto power off. ‹ Well-designed protection point for transportation. ‹ Concave handle for easy carrying. Specifications: Model Capacity Division Resolution ESW-3 3kg 0.5g 1g 1/6,000 1/3,000 ESW-6 6kg 1g 2g 1/6,000 1/3,000 ESW-15 15kg 2g 5g 1/7,500 1/3,000 ESW-30 30Kg 5g 10g 1/6,000 1/3,000 Operating Temperature: Non-approval model: 0°C ~ 40°C (32°F ~ 104°F) Approval model: -10°C ~ 40°C (14°F ~ 104°F) Dimensions: 240 x 120 x 280 mm ( W x H x D) Weight of the scale: Around 3.5kg 240mm 280mm 120mm

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 . . . . . . . . . . Pcs 1-2 Power Supply Power Supply Selection 1. DC 6V / 4Ah rechargeable battery 2. AC 110V~240V (±10%) adapter Power Consumption 14mA (system no backlight;Single display) about 275 hours 19mA (system backlight;single display) about 200 hours Low Battery Warning Please note when the ( ) symbol keeps flashing on the display, the batteries should be changed.  The scale will turn off automatically after a few hours when the low battery warning symbol shows up. The scale must be fully charged, before operating again. 1-3 Panel and Keyboard Introduction Icon Introduction STABLE : The weight is stable. GROSS : The scale is in the gross mode. The display shows the goods and any container weight. This Gross status indication is on when the TARE function is used. : The unit weight is not sufficient. When the icon is on, the counting function is operational but the count may contain errors. : The sampling size is not sufficient When the icon is on, the counting function is operational but the count may contain errors. Keyboard Function ON/ZERO KEY This key possesses two functions: Power On and Zero function. OFF KEY When the scale is switched on, press the OFF key, the scale will switch off. TARE KEY The tare function will not operate during the following conditions:

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 1. When the scale powers on if the weight is negative and after a container is placed on the weigh pan if the weight is still below zero. 2. The tare value is over the full scale capacity. UNITS KEY Press the UNITS key to switch weight units; the icons will indicate the active units. NET/GROSS KEY In the Tare mode, the screen displays the “TARE” icon; press the NET/GROSS key to switch between the “Net value” and the “Gross value”. 1-4 Operating the Scale POWER ON When the scale is off, press the ON/ZERO key, the scale will switch on. POWER OFF When the scale is on, press the OFF key, the scale will switch off. ZERO When the weigh pan is empty (free of load) and the display is not showing zero, press the ON/ZERO key to zero the scale. At zero, the “Æ0Å” indication is on.  When the weight value is within the zero range, the zero function operates to zero the scale or cancel the tare function.  Zero range: The OIML & NTEP models have a zero range of ± 2% of Full Scale. The Sri Lanka model has a zero range of ± 4% of Full Scale. SWITCHING UNITS Press the UNITS key to switch weight units, the icons or arrows will indicate the active units as appropriate. The units available are dependent on the exact scale model.  After power off, the scale will memorize the active units. When the scale is powered on again, it displays the previously active units. TARE FUNCTION (1) Put a container on the weigh pan and after the weight is stable, press the TARE key to zero the weight of the container. The screen displays the “Net” icon. (2) Put the goods in the container, the screen displays the net weight value of the goods. (3) Remove the full container; the screen displays the negative weight value of the container. At this time pressing the TARE key again will cancel the tare and the scale reverts back to zero. The “Net” icon is switched off.  The tare function can be operated continually to the full weighing capacity of the scale.  Continual tare operation is adding or removing tare objects on weigh pan and pressing the TARE key each time. NET/GROSS FUNCTION In the Tare mode, the screen displays the “Net” icon, press the NET/GROSS key to switch between the “Net value” and the “Gross value”.  When the GROSS icon is on, the weight value on the display is the total amount of the tare value and net value.  At the Gross status, only OFF and NET/GROSS keys are functional.  NET/GROSS key is only used in Tare mode.

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 Pcs . . . . . . . . . . Pcs . . . . . . . . . . SIMPLE COUNTING FUNCTION (1) Use the UNITS key to enter into the “PCS” mode (2) Press the NET/GROSS key to select the counting sample size (S = 10, S = 20, S = 50, S = 100, S=200). The LCD shows , , , , in order. (3) Put the samples on the weigh pan and press the UNITS key, the screen displays “------”. After the sampling process is complete, put the goods on the weigh pan and the screen shows the quantity of the items.  The sample weight should be heavier then the minimum capacity of the scale (20d), If not the arrow pointing to the icon will be activated.  The weight of a sample should be heavier than the 0.2d (d=division), or the arrow pointing to the icon will be on.  When the or are indicated, the scale is still operational but the count may contain errors.  To power off in this mode, the scale will memorize the “Pcs” unit. When the scale is powered on again, it directly enters the simple counting mode.  While the “Auto unit weight average” function is available in the Advanced Function, the goods on the weigh pan are 5pcs greater than the sample size and less than double the sample size, the scale will automatically re-sample the unit weight. 1-5 Self-Test Mode  Set the switch SWA1 on the bottom of machine to the LOCK position.When power is off, hold NET/GROSS , and press ON/ZERO key, Wait till display shows to enter “Self-Test Mode”. Press UNITS key Press ON/ZERO key Press ON/ZERO key Press ON/ZERO key Press ON/ZERO key Press UNITS key Press UNITS key Press UNITS key

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 1-6 Error Messages ⇒ Unable to read the EEPROM The EEPROM is not mounted yet, or the circuit near EEPROM is broken. ⇒ Initial zero is higher than the zero range when switching the indicator on. (Approval models) ⇒ Initial zero is lower than the zero range when switching the indicator on. (Approval models) ⇒ Internal value is below Zero. ⇒ A/D IC malfunction (cannot read A/D value). The load cell may not be connected to the scale correctly. ⇒ The weight of the object is over 9 divisions of the maximum capacity. ⇒ A/D IC value is over the maximum range. 1-7 Weight Unit (kg) 1 g = 0.001 kg (g) 1 g = 1 g (lb) 1 g = 0.002204623 lb (lb/oz) 1 g = 0.03527396 oz INTERNAL VALUE MODE (must hook up Load Cell to test) c Press TARE to enter, and the display shows internal value d Please check whether the internal value has changed obviously with weight changing. e Please check the backlight. f Press ON/ZERO key to back to the last screen , the display shows KEYPAD TEST MODE c Press TARE to enter, display shows Keypad’s internal code: TARE key= 07 UNITS key= 06 NET/GROSS key=05 d Press ON/ZERO key to back to the last screen , the display shows FIRMWARE VERSION DISPLAY MODE c Press TARE to enter , display shows the firmware version d Press TARE key again, the display shows maintenance number for 2 secs e Press ON/ZERO key to back to the last screen, display shows BACK TO THE LAST SCREEN Press TARE key to exit self-test mode, the scale will restart automatically.

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 Chapter 2 Advanced Functions 2-1 Advanced Function Setting Table Below is an overview of the advanced functions. For detailed settings refer to the following sections: DISPLAY LEVEL 1 FUNCTION DISPLAY LEVEL 2 FUNCTIONS Exit the ADVANCED FUNCTION setting mode --- --- Return to theADVANCED FUNCTION setting menu Automatic backlight function setting Automatic power-off timer setting Hi/Lo/OK function setting Restore the default settings Noise filter setting Hold function setting General Function setting mode Auto unit weight averaging setting External Weight Calibration --- --- Reserved Reserved Reserved

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 2-2 Advanced Function Setting Workflow In the weighing mode, press the NET/GROSS and ON/ZERO keys at the same time to enter the Advanced Function setting mode. The LCD shows . Overall workflow of the Advanced Function setting mode: ⇒ General Function setting mode ⇒ External Weight Calibration ⇒ Reserved ⇒ Exit the Advanced Function setting mode Refer to the following sections for the detailed operation procedures of each function setting. Press UNITS key Press ON/ZERO key Press ON/ZERO key Press ON/ZERO key Press ON/ZERO key Press UNITS key Press UNITS key Press UNITS key

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 2-3 General Function Setting There are 7 functions in the general function setting mode from to . Workflow of the General Function setting: ACTIONS DISPLAY NOTE ⇒ Return to the Advanced Function Setting Mode Menu ⇒ Automatic Backlight Function Settings ⇒ Automatic Power-off Timer Settings ⇒ Hi/Lo/OK Settings ⇒ Restore the Default Settings ⇒ Noise Filter Settings ⇒ Hold Function Settings ⇒ Auto Unit Weight Averaging Setting Refer to the following sections for detailed operation procedures of each setting. Press TARE key Use the keys to select the function Key in “00” and press TARE key to return to the Advanced function setting menu ON/ZERO key ⇒ Upward key (from 0 to 9) UNITS key ⇒ Downward key (from 9 to 0) TARE key ⇒ Move the cursor to right NET/GROSS key ⇒ Move the cursor to left

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 2-3-1 Automatic Backlight Function Setting Select in the General Function setting mode to change the backlight function setting. Automatic backlight function When the weight is over 10d, the display backlight will be on. After the weight is stable for 10 seconds or when the scale returns to zero, the display backlight switches off. DISPLAY ACTIONS NOTE Key in the parameter “00” Press TARE key Use ON/ZERO orUNITS key to select function “on” or “off Press TARE key Press TARE key to complete the general setting procedures LCD displays the last status

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 Automatic power-off timer setting Use ON/ZERO or UNITS key to key in parameter 0 ⇒ No auto power-off 1 ⇒ When the scale is idle for 1 minute, the scale automatically switches off 2 ⇒ When the scale is idle for 2 minutes, the scale automatically switches off 9 ⇒ When the scale is idle for 9 minutes, the scale automatically switches off 2-3-2 Automatic Power-off Timer Setting Select in the General Function setting mode to change the automatic power-off timer setting. LCD displays the last status Automatic power-off function When the weight on weigh pan is less than 10d or keeps idle for the set time, the scale will automatically switch off. Press TARE key Use ON/ZERO or UNITS key to key in parameter Press TARE key ACTIONS DISPLAY NOTE ON/ZERO key ⇒ Upward key (from 0 to 9) UNITS key ⇒ Downward key (from 9 to 0) TARE key ⇒ Move the cursor to right NET/GROSS key ⇒ Move the cursor to left. Key in the parameter “00” Press TARE key to complete the general setting procedures

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 lb lb lb lb 2-3-3 Hi/Lo/OK Function Setting Select in the General Function setting mode to set the Hi/Lo/OK function. This function is available in all unit modes. In one specific unit mode, enter to set the Hi/Lo/OK values.  When the high limit and low limit are both set as “0”, the Hi/Lo/OK function is disabled. ACTIONS DISPLAY NOTE LCD displays the last status Press TARE key Key in the desired high limit value Press TARE key Key in the desired low limit value Press TARE key Key in the parameter setting for alarm Press TARE key LCD displays the last status LCD displays the last status . . . . Alarm setting (a) (b) (c) The definition of a, b, c positions: (a) ⇒ 1 = beep sound on 0 = beep sound off (b) ⇒ 1 = beep sound on when stable 0 = beep sound on when unstable (c) ⇒ 1 = beep sound on when the weight is between high and low limits 0 = beep sound on when the weight is not between high and low limits and higher than 10d ON/ZERO key ⇒ Upward key (from 0 to 9) UNITS key ⇒ Downward key (from 9 to 0) TARE key ⇒ Move the cursor to right NET/GROSS key ⇒ Move the cursor to left. Key in the parameter and then press TARE key to go back to the Advanced function setting menu

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 2-3-4 Restore to the Default Setting Select in the General Function setting mode to restore to the default setting.  The default setting includes the following: 1) External weight calibration 2) HI/LO/OK setting value 3) Noise filter setting (External) 4) Sampling setting for the counting function  For OIML, NTEP or Sri Lanka approved models, setting is disabled. ACTIONS DISPLAY NOTE ⇒ Return (Cancel the restoration) ⇒ Restore to the default setting Press TARE key Use ON/ZERO or UNITS keys to select “return” or “format” Press TARE key ON/ZERO key ⇒ Upward key (from 0 to 9) UNITS key ⇒ Downward key (from 9 to 0) TARE key ⇒ Move the cursor to right NET/GROSS key ⇒ Move the cursor to left. Key in the parameter “00” Press TARE key to complete the general setting procedures

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 2-3-5 Noise Filter Setting Select in the General Function setting mode to set the noise filter setting. Returning to the zero point setting Use ON/ZERO or UNITS key to key in the parameters or zero point Default setting = 0 0 ⇒ No skip 5 ⇒ skip 5d 1 ⇒ skip 1d 6 ⇒ skip 6d 2 ⇒ skip 2d 7 ⇒ skip 7d 3 ⇒ skip 3d 8 ⇒ skip 8d 4 ⇒ skip 4d 9 ⇒ skip 9d  When the weight on the scale is over 1/3 full capacity, the function is on. Digital switch & Stabilization range setting LCD displays the last parameter setting Filter parameter setting LCD displays the last parameter setting Filter parameter setting Use ON/ZERO or UNITS keys to key in the parameters. Default setting = 5 Parameter 0 ~ 9, the larger the number, the faster the filter response. Fast response can lead to weight instability. Digital switch & Stabilization range setting Use ON/ZERO or UNITS keys to key in the parameters. Default setting = 0 Parameter 0 ~ 9, the larger the number the more stable the weight. ACTIONS DISPLAY NOTE Press TARE key Use ON/ZERO or UNITS key to key in the parameters Press TARE key Use ON/ZERO or UNITS key to key in the parameters Press TARE key Use ON/ZERO or UNITS key to key in the parameters Press TARE key Returning to zero point setting LCD displays the last status Key in the parameter and then press TARE key to go back to the Advanced function setting menu  For OIML, NTEP or Sri Lanka approved models, setting is disabled.

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 2-3-6 Hold Function Setting Select in the General Function setting mode to set the hold function. Hold function setting Use ON/ZERO or UNITS keys to key in the parameters Default setting = 0 0 ⇒ Hold function disabled 1 ⇒ “Peak hold” mode 2 ⇒ “Stable hold 1” mode 3 ⇒ “Stable hold 2” mode Hold function setting LCD displays the last parameter setting = Hold function disabled = “Peak hold” mode Keep displaying the maximum weight when the weight is continually changing To exit this mode, press any key. = “Stable hold 1” mode When the weight is stable, the LCD shows the current weight value. To exit this mode, press any key. = “Stable hold 2” mode When the weight is stable, the LCD shows the current weight value. When the weight returns to zero (<10d), the hold mode is cancelled automatically. ACTIONS DISPLAY NOTE ON/ZERO key ⇒ Upward key (from 0 to 9) UNITS key ⇒ Downward key (from 9 to 0) TARE key ⇒ Move the cursor to right NET/GROSS key ⇒ Move the cursor to left. Press TARE key Use ON/ZERO or UNITS key to key in the parameters Press TARE key Key in the parameter “00” Press TARE key to complete the general setting procedures

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 Press TARE key Use ON/ZERO or UNITS key to key in the parameters Press TARE key 2-3-7 Auto Unit Weight Averaging Setting Auto unit weight averaging setting Use ON/ZERO or UNITS keys to key in the parameters Default setting = 0 0 ⇒ Auto unit weight averaging 1 ⇒ Non auto unit weight averaging ON/ZERO key ⇒ Upward key (from 0 to 9) UNITS key ⇒ Downward key (from 9 to 0) TARE key ⇒ Move the cursor to right NET/GROSS key ⇒ Move the cursor to left. Auto unit weight averaging setting LCD displays the last parameter setting Key in the parameter “00” Press TARE key to complete the general setting procedures

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 kg kg kg 2-4 Weight Calibration In the weighing mode, press the NET/GROSS and ON/ZERO keys at the same time to enter the Advanced Function setting mode. The LCD shows and use the NET/GROSS or UNITS key to select to enter the weight calibration mode.  For approved models, is disabled.  Weight calibration conditions: The calibration weight value placed on the weight pan must be over e100, and the standard deviation of the weight must be within 10%. The LCD displays the calibration weight value (the maximum capacity of 1st unit) and the unit. The digit on the right side keeps flashing. The scale is calculating the internal value of the zero point. After stabilization, the LCD shows the calibration weight value. Press TARE key When the digit on the right flashes, ensure that the weigh pan is empty. Then Press the TARE key. After stabilization Place the displayed weight on the weigh pan. Press the TARE key. The scale calculates the full capacity internal value and after stabilization, the buzzer beeps 3 times. Remove the weight from the weigh pan and the procedure is completed. . . ACTIONS DISPLAY NOTE ON/ZERO key ⇒ Upward key (from 0 to 9) UNITS key ⇒ Downward key (from 9 to 0) TARE key ⇒ Move the cursor to right NET/GROSS key ⇒ Move the cursor to left.

EXCELL PRECISION CO., LTD.

02005311 ZSME3000000272 Appendix 1 7-Segment Display Characters Digit 7 segments letter Alphabet 7 segments letter Alphabet 7 segments letter 0 A N 1 B O 2 C P 3 D Q 4 E R 5 F S 6 G T 7 H U 8 I V 9 J W K X L Y M Z