Extech Instruments 42509 Operation & User’s Manual

Brand: Extech Instruments
Category: Thermometer
Model: 42509 (Operation & User’s Manual)
File Type: PDF
File Size: 0.21 Mb
Pages: 10
Text of Extech Instruments 42509 Operation & User’s Manual

Extech Instruments 42509 42509 V1.0 07/09

2 Introduction Congratulations on your purchase of the Model 42509 IR Thermometer with Color Alert. This Infrared thermometer measures and displays non-contact temperature readings up to 950 oF (510 oC). Dual laser pointers ensure accurate targeting and temperature measurement. The Color Alert feature indicates when High or Low set points are exceeded. The adjustable emissivity feature allows the IR thermometer to measure the temperatur
42509 V1.0 07/09 3 Meter Description 1. Dual Laser pointers 2. LCD Display 3. Function Buttons 4. Measurement Trigger 5. Battery and F/C Switch compartment DISPLAY 1. SCAN, measurement in progress 2. HOLD, last measurement locked in display 3. Laser pointer active 4. Power locked ON 5. High limit alarm 6. Low limit alarm 7. C or F temperature units 8. Main temperature display 9. Low battery icon 10. MAX icon 11. Emissivity setting 12. Emissivity icon 13
42509 V1.0 07/09 4 Operating Instructions Temperature Measurements 1. Hold the meter by its handle and point it toward the surface to be measured. 2. Pull and hold the trigger to turn the meter on and begin testing. The temperature reading, MAX temperature reading, the ‘SCAN’ icon, the emissivity value, and the unit of measure will appear. 3. Release the Trigger and the reading will hold for approximately 7 seconds (HOLD will appear on the LCD) afte
42509 V1.0 07/09 5 MAX (maximum) temperature display The highest reading encountered during a single measurement scan is displayed in the MAX display Backlight 1. Press and release the Trigger 2. While HOLD is on the display, press the backlight button once to turn on the backlight on or off. 3. The backlight will illuminate in the LCD when the feature is enabled. 4. The status of the backlight will be stored in memory and will remain as the “turn-on
42509 V1.0 07/09 6 Color Alert High and Low Alarm Feature The meter has a programmable high and low alarm feature. When either alarm point is reached the meter will alert the user via a flashing red LED backlight, as well as an audible beep and a blinking LCD display icon. The alarm limit is set and the feature is enabled/disabled using the MODE button. The setting is stored and memory and will remain as the “turn-on” condition until changed. Temper
42509 V1.0 07/09 7 IR Measurement Notes 1. The object under test should be larger than the spot (target) size calculated by the field of view diagram (printed on the side of the meter and in this guide). 2. Before measuring, be sure to clean surfaces that are covered with frost, oil, grime, etc. 3. If an object's surface is highly reflective, apply masking tape or flat black paint to the surface before measuring. Allow time for the paint or tape to adju
42509 V1.0 07/09 8 Emissivity and IR Measurement Theory IR Thermometers measure the surface temperature of an object. The thermometer’s optics sense emitted, reflected, and transmitted energy. The thermometer’s electronics translate the information into a temperature reading which is then displayed on the LCD. The amount of IR energy emitted by an object is proportional to an object's temperature and its ability to emit energy. This ability is known
42509 V1.0 07/09 9 Support line (781) 890-7440 Technical support: Extension 200; E-mail: [email protected] Repair & Returns: Extension 210; E-mail: [email protected] Product specifications subject to change without notice For the latest version of this User’s Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451 Specifications Ran

Extech Instruments Thermometer Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
EA20

EA20 (Thermometer ePDF Manual, #6H8L1O)

5 0.36 Mb 900 153 11-09-2026
IR100

Extech Instruments IR100 Guide (Operation & user’s manual), @S1A12E

2 1447 333 04-05-2026
42500

#R7ZB8S: 42500 Thermometer Operation & user’s manual

4 0.15 Mb 422 72 30-04-2026

Thermometer: Similar Manuals