Multi standard NTSC, PAL, YPbPr,

RGB-Decoder/Converter Component and Composite Analogue Video Converter Rev. 3 Flashlink User Manual ADC-SDI-CC

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 2 Revision history The latest version is always available in pdf-format on our web-site: http://www.network-electronics.com/ Current revision of this document is the uppermost in the table below. Revision Replaces Date Change Description 3 2 2008-07-14 Added Declaration of Conformity. 2 1 2007-10-23 New front page and removed old logo. 1 0 2007-10-09 Added Materials Declaration and EFUP 0 B 03.03.05 Specification update and changed ConQuer to flashlink®. B A 02.09.04 First preliminary release A 12.08.04

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 3 Index Quick Start Guide for ADC-SDI-CC.........................................................................................................4 1. General......................................................................................................................................................5 2. Specifications............................................................................................................................................6 3. Connector module....................................................................................................................................7 3.1 Correspondence of connectors and signals.........................................................................................7 3.2 Mounting the connector module..........................................................................................................7 4. Configuration and Setup.........................................................................................................................8 4.1 Setting the DIP switches......................................................................................................................8 4.2 Reset...................................................................................................................................................10 5. Module status .........................................................................................................................................11 5.1 GPI ALARM – Module Status Outputs..............................................................................................11 5.2 Front Panel - Status Monitoring .......................................................................................................12 6. Interface with GYDA and RS-422 command set................................................................................13 6.1 ADC-SDI-CC Command table...........................................................................................................13 6.2 The “?” command .............................................................................................................................13 6.3 The “info” command.........................................................................................................................14 6.4 Video modes commands.....................................................................................................................14 6.5 Mark Field 1, Pedestal and Comb - commands. ...............................................................................15 6.6 get, set, eget and eset.........................................................................................................................15 General environmental requirements for Network flashlink® equipment...........................................16 Product Warranty .....................................................................................................................................17 Materials declaration and recycling information...................................................................................18 Materials declaration ................................................................................................................................18 Environmentally-friendly use period.......................................................................................................18 Recycling information ...............................................................................................................................19 EC Declaration of Conformity .................................................................................................................20

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 4 Quick Start Guide for ADC-SDI-CC Without GYDA controller (This is the default setting upon shipping) 1. Set DIP-switch 1 on (towards backplane), switches 2 and 3 according to the input mode you want (see Table 2 on page 9). 2. Insert ADC-SDI-CC into a slot in the sub-rack. 3. Attach Analogue input (CVBS, S-Video, RGB+sync or YPbPr) and SDI-output to the backplane module (see Figure 2 on page 7). 4. Power on. After some seconds the ADC-SDI-CC will be running, and the input detected. All LED’s will be green and the SDI output active. If this is not the case, please see section 5.2 Front Panel - Status Monitoring on page 12. With GYDA controller (firmware> 1.1) Insert ADC-SDI-CC into a slot in the sub-rack. Attach Analogue input (CVBS, S-Video, RGB+sync or YPbPr) and SDI-output to the backplane module (see Figure 2 on page 7). Power on. After a few seconds the ADC-SDI-CC will be running, and the card detected by GYDA. Use GYDA to set up which analogue video format to use, CVBS, S-Video, RGB+sync or YPbPr. All LED’s will now be green and the SDI output active. The card settings are stored on the card which means that the card will remember its configuration despite any eventual power loss.

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 5 1. General The flashlink ® ADC-SDI-CC is a high quality digital video decoder that digitises and decodes all popular baseband video formats into SDI 4:2:2 digital component video. The ADC-SDI-CC supports the analogue-to-digital conversion of component RGB and YPbPr signals, as well as the decoding of NTSC and PAL composite and S-video into component digital video. This decoder features four 10-bit A/D converters running with 2 x oversampling (27MHz), which are then digitally filtered and decimated to the 1 x pixel rate giving a higher signal-to-noise ratio for each input channel. When used with the GYDA control system, gain adjustments may be made to each analogue input. Composite video decoding utilises a 5-line adaptive comb filter for both the luma and chroma signal paths to reduce cross-luma and cross-chroma artefacts. A alternative chroma trap filter is also available. On composite and S-video inputs, the user can control video characteristics such as contrast, brightness, saturation and hue via the GYDA control interface. The GYDA system controller is used with all flashlink and flashlink modules providing a common control and monitoring platform. ADC-SDI-CC features: • Multi-standard NTSC, PAL, YPbPr, RGB Decoder/Converter • 10 bit 4:2:2 SDI video quality • 5 line adaptive comb filter for NTSC/PAL decoding • EDH generation and insertion • 2 x oversampling of both composite and component video • 10 bit component 8:8:8 oversampling with digital 4:2:2 decimation and down-conversion • VBI data transparent • 3 SDI outputs Figure 1 – Simplified block diagram of the ADC-SDI-CC card

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 6 2. Specifications Digital Serial Output Signal type: SMPTE 259M / ITU-R BT.601 Connector: BNC Impedance: 75 ohm Return loss: >15dB @ 270MHz Jitter: < 0.2UI Peak to peak signal level: 800mV ± 80mV Composite and Y/C Input: Signal type: Composite video, PAL 625/50Hz or NTSC 525/60Hz Y / C (S-video) Connector: BNC Impedance: 75 ohm Signal level: 1Vp-p Return loss: >40dB Component and RGB Input: Signal rate: 625/50Hz or 525/60Hz Signal type: RGB without setup, with separate sync. SMPTE / EBU Y, Cr, Cb Connector: BNC Impedance: 75 ohm Signal level: Y = 1Vp-p. Cb, Cr, R, G, B = 0.7Vp-p Return loss: >40dB Processing Performance: Signal path: 10 bits Sampling: 27MHz, 2 x oversampling Luma/Chrome separation: selectable 5 line adaptive comb filter or chroma trap filter Video bandwidth: 6MHz Hue Accuracy 0.5° typical Colour Saturation Accuracy 0.8% typical Luminance Nonlinearity 0.6% typical SNR (unified weighted): 66dB typical Diff. gain: <1.0% Diff. phase: <1.0° Video processing delay 3 video lines Power: +5V DC / 2.75W -15V DC / 0.5W

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 7 3. Connector module The ADC-SDI-CC has a dedicated connector module: ADC-SDI-CC-C1. This module is mounted at the rear of the sub-rack. The module is shown in Figure 2 . Figure 2 - ADC-SDI-CC-C1 connector module. 3.1 Correspondence of connectors and signals The ADC-SDI-CC-C1 connector module has 7 BNC's: CVBS/Y Analogue input: CVBS, SYNC for RGB or S-Video Luma. R/Pr Analogue input: Red or component Pr. G/Y Analogue input: Green or component Y. B/Pb/C Analogue input: Blue, component Pb or S-Video Chroma. SDI-OUT Digital SDI output SDI-OUT Digital SDI output SDI-OUT Digital SDI output SDI1, SDI2 and SDI3 are equivalent SDI outputs. Note: The analogue inputs are internally terminated with 75Ω on the ADC-SDI-CC card. 3.2 Mounting the connector module The details of how the connector module is mounted, is found in the user manual for the sub-rack frame FR-2RU-10-2. This manual is also available from our web site: http://www.network-electronics.com/

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 8 4. Configuration and Setup Figure 3 - ADC-SDI-CC simplified silkscreen. he DC-SDI-CC card, without the need of a GYDA controller. The switches are numbered from '1' towards the . A switc the tap is placed in direction of the front handle. Switch # 4.1 Setting the DIP switches The ADC-SDI-CC card has a Dual-Inline switch (DIP-switch) that has 10 individual On/Off switches. The purpose of these switches is to provide an easy interface to some of the most used features of t A top of the card, see Figure 3 h is off when Function Comment 1 Manual mode on/off When on, enables switches 2, 3, 4, 5, 6 and 8. 2 Input Channel select 3 Input Channel select According to Table 3. 4 Mark Field 1 enable on/off e Mark Field 1-feature enabled. When on, th 5 Comb filter/Trap filter When on, the comb filter is selected. When off, the trap filter is selected. 6 Pedestal on/off ur analogue video, t to on. When black level is 0 IRE, set to off. This setting andard. If a setup level of 7,5 IRE is present on yo se only applies to 525 lines video st 7 Reserved 8 Factory Reset on/off To reset the internal EEPROM. 9 Reserved 10 Run mode on/off For factory use only Table 1: Summary of the DIP switches. Switch 7, 9 and 10 are mainly for factory use, while switches 1, 2, 3, 4, 5 and 6 will be used when no GYDA controller is available. Switch 1 - Manual mode

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 9 Switch 1 is the manual mode switch. If on, the ADC-SDI-CC may be operated with the switches. If off, DA controller. witch 1 in on position ith switch 1 off: mode, switches 2, 3, 4, 5, 6 and 8 do not have any effect. ith switch 1 on: e functionality of switches 2, 3, 4, 5 , 6 and 8 is as follows: witches 2 and 3 tion. See Table 2. F e sw f. #3 #2 nnel Select the ADC-SDI-CC is to be used with a GY Factory setting is s W While in automatic W In manual mode, th S These two switches determine the input selec actory s tting is itch 2 and switch 3 of Sw Sw Input Cha 0 0 CVBS 0 1 S-Video 1 0 YPbPr 1 1 RGBS Table 2: Manual selection of video mode Mark Field 1-feature is enabled and the card inserts a marker on line x of each field . This features gives improved encoding quality when used with an encoder like the DAC-SDI which tting is switch 4 in on position. witch 5 selects which filter to use when separating Luma from Chroma in CVBS. With switch 5 on, the off, the chroma trap filter is selected. tting is switch 5 in on position. on, the black level will set to 7,5 IRE. With switch 6 off, the black level will be 0 IRE. This switch only affects 525 lines used in the USA and 0 IRE in Japan. Factory setting is switch 6 in on position. Switch 4 Switch 4 turns on/off the Mark Field 1-feature. With switch 4 off the Mark Field 1-feature is disabled, with switch 4 on the 1 can use this feature. Factory se Switch 5 S 5-line comb filter is selected, with switch 5 Factory se Switch 6 Switch 6 selects whether pedestal is present on the analogue video. With switch 6 be video. Typically a black level of 7,5 IRE is

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 10 Switches 7 and 9 - Reserved These switches are reserved and should always be in the off position. Factory setting are switch 7 and 9 in off position. Switch 8 - Reset to factory default ADC-SDI-CC contains an EEPROM which stores the configuration of the card. Switch 8 can be used to reset the EEPROM to the factory default. Follow the procedure described below. Action Comment 1 Power down. 2 Turn switch 8 on. Switch 1 must also be turned on for this to have effect. 3 Power up. ADC-SDI-CC enters a special state where the EEPROM is restored to factory default values. This is flagged by the Card State LED, which starts to blink yellow. 4 Power down. 5 Turn switch 8 off. If you want the DIP switches to be placed in the factory default position, this is the time to do so: Switch 10 should, as always, be turned to the on position. Switch 1 may be turned on or off. 6 Power up. The card EEPROM is now reset to factory settings. Table 3: Method to restore the ADC-SDI-CC card to factory settings. Remember to let some seconds pass by each time you power down, to allow capacitors to be fully discharged. Switch 10 - Run mode Switch 10 is purely used for service upgrade of the ADC-SDI-CC card. It should always be in the on position. If switch 10 is in the off position, the Card State LED will light up red, and the ADC-SDI-CC card will enter programming mode. This causes no harm, but the card will not work in this mode. Factory setting is switch 10 in on position. 4.2 Reset The push-button just behind the front LEDs is a reset switch, see Figure 3 . It has the same effect as a power off – power on cycle.

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 11 5. Module status The status of the module can be monitored in two ways. 1. GYDA System Controller (optional). 2. LED’s at the front of the sub-rack. The LED’s are mounted on the module itself, whereas the GYDA System Controller is a separate module which gives detailed information on the card status. The functions of the LED’s are described on the next page. The GYDA controller is described in a separate user manual. This manual is available on our web site: http://www.network-electronics.com/ 5.1 GPI ALARM – Module Status Outputs These outputs can be used for wiring up alarms for third party control systems. The GPI outputs are open collector outputs, sinking to ground when an alarm is triggered. The GPI connector is shown in Figure 4 . Electrical Maximums for GPI outputs Max current: 100mA Max voltage: 30V ADC-SDI-CC module GPI pinning: Signal Name Pin # Mode Status General error status for the module. Pin 1 Open Collector Input No video input detected Pin 2 Open Collector VCXO Module not gen-locked to video input Pin 3 Open Collector SDI Output No SDI output present Pin 4 Open Collector Ground 0 volt pin Pin 8 0V. Figure 4 - GPI Outlet

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 12 5.2 Front Panel - Status Monitoring The status of the module can be easily monitored visually by the LED’s at the front of the module. The LED’s are visible through the front panel as shown in Figure 5 below. (Text not printed on the front panel). Figure 5 - Front panel indicator for ADC-SDI-CC The ADC-SDI-CC has 4 LED’s each showing status information. The position of the different LED’s is shown in Figure 5 . Diode \ state Red LED Yellow LED Green LED No light Card State Module is faulty Start-up-sequence is running Module is OK Module power is OK Module has no power or memory fault Input No video input detected Video input detected VCXO No input detected Input signal is detected. Video not yet locked or input comes from a VCR Input signal is detected, and properly locked SDI Output No SDI output Correct SDI output Table 4 - Front panel LED indicator overview

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 13 6. Interface with GYDA and RS-422 command set All commands follow the flashlink® protocol and can be used for direct control access to the module. The control system can either be a GYDA or a third-party control system with integrated flashlink® protocol. The module can also be manually controlled with a VT100 compatible terminal program. The protocol can be found on our web page; http://www.network-electronics.com 6.1 ADC-SDI-CC Command table Command Response Comment ? Yes The “Hello” command. info Yes Gives back the card state. CVBS “OK” Set video format to CVBS. Svideo “OK” Set video format to S-Video. RGB “OK” Set video format to component RGB + sync. YPbPR “OK” Set video format to component YPbPr. MarkF1 on “OK” Turn on the Mark Field 1-feature. MarkF1 off “OK” Turn off the Mark Field 1-feature. Comb on “OK” Set chroma luma separation filter to 5-line comb filter. Comb off “OK” Set chroma luma separation filter to chroma trap filter. Pedestal on “OK” Pedestal is present. Pedestal off “OK” Pedestal is not present. Calibrate “OK” Calibrates RGB gain. Must be in RGB and input must be 75% colour bar. eget [0xHH] Yes Get a value from a numbered eeprom register. eset [0xHH] [0xHH] “OK” Set a value to a numbered eeprom register. get [0xHH] Yes Get a value from a numbered register. set [0xHH] [0xHH] “OK” Set a value to a numbered register. Table 5 - All commands available to the user 6.2 The “?” command According to the flashlink®, no card can use the RS422-bus before it has been activated with the “?” (hello) command. The response from ADC-SDI-CC will be: xxxxADC-SDI-CC\ PIC sw rev X.X.X\ FPGA sw rev X\ Protocol ver X.X

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 14 Here xxxx denotes the source and destination rack and slot coordinates, while X represents a version number. As of primo July 2004, these revisions would be: xxxxADC-SDI-CC\ PIC sw rev 1.0.2\ FPGA sw rev 6\ Protocol ver 1.0 6.3 The “info” command This command report the entire state of the card. An example: xxxxCVBS\ Locked 50Hz\ Field 1 mark on\ Comb on\ Pedestal on Status of Status string Comment CVBS CVBS is selected Svideo Svideo is selected YpbPr YPbPr is selected Input Select RGB RGB is selected Locked 50Hz Locked to 625 lines 50 Hz. Locked 60Hz Locked to 525 lines 60 Hz. Not locked 50Hz Not locked, previously locked to 50Hz. Analogue input. Not locked 60Hz Not locked, previously locked to 60Hz. Field 1 marking on The Mark Field 1-feature is turned on. Field 1 marking Field 1 marking off The Mark Field 1-feature is turned off. Comb on Comb filter selected. Chroma filter Comb off Chroma trap filter is selected. Pedestal on Pedestal present is selected. Pedestal Pedestal off Pedestal not present is selected. Table 6: The info command broken up in components. The “info” command is composed by many minor lines, fully specified in table 6. In general, when a condition is normal, it is not reported. For instance, pedestal is reported when locked to 50Hz, even tough the setting has no effect on the video. 6.4 Video modes commands. The CVBS, RGB, Svideo and YPbPr commands sets the video input mode. Remember that RGB -mode needs separate sync on the CVBS/Luma channel. This sync may be a synchronous CVBS-signal.

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 15 6.5 Mark Field 1, Pedestal and Comb - commands. Commands to turn on/off the Mark Field 1-feature, Pedestal and the Comb filter commands are straightforward text, see Table 5 . 6.6 get, set, eget and eset. These commands are for internal factory use. The end-user should avoid these commands.

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 16 General environmental requirements for Network flashlink® equipment 1. The equipment will meet the guaranteed performance specification under the following environmental conditions: • Operating room temperature range 0°C to 40°C • Operating relative humidity range up to 90% (non-condensing) 2. The equipment will operate without damage under the following environmental conditions: • Temperature range -10°C to 50°C • Relative humidity range up to 95% (non-condensing)

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 17 Product Warranty The warranty terms and conditions for the product(s) covered by this manual follow the General Sales Conditions by Network Electronics AS. These conditions are available on the company web site of Network Electronics AS: www.network-electronics.com

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 18 Materials declaration and recycling information Materials declaration For product sold into China after 1st March 2007, we comply with the “Administrative Measure on the Control of Pollution by Electronic Information Products”. In the first stage of this legislation, content of six hazardous materials has to be declared. The table below shows the required information. Toxic or hazardous substances and elements 組成名稱 Part Name 鉛 Lead (Pb) 汞 Mercury (Hg) 镉 Cadmium (Cd) 六价铬 Hexavalent Chromium (Cr(VI)) 多溴联苯 Polybrominated biphenyls (PBB) 多溴二苯醚 Polybrominated diphenyl ethers (PBDE) ADC-SDI-CC X O O O O O O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363-2006. X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T11363-2006. Environmentally-friendly use period The manual must include a statement of the “environmentally friendly use period”. This is defined as the period of normal use before any hazardous material is released to the environment. The guidance on how the EFUP is to be calculated is not finalised at the time of writing. See http://www.aeanet.org/GovernmentAffairs/qfLeOpAaZXaMxqGjSFbEidSdPNtpT.pdf for an unofficial translation of the draft guidance. For our own products, Network Electronics has chosen to use the 50 year figure recommended in this draft regulation. Network Electronics suggests the following statement on An “Environmentally Friendly Use Period” (EFUP) setting out normal use: EFUP is the time the product can be used in normal service life without leaking the hazardous materials. We expect the normal use environment to be in an equipment room at controlled temperature range (0ºC - 40ºC) with moderate humidity (< 90%, non- condensing) and clean air, not subject to vibration or shock. Further, a statement on any hazardous material content, for instance, for a product that uses some tin/lead solders: Where a product contains potentially hazardous materials, this is indicated on the product by the appropriate symbol containing the EFUP. The hazardous material content is limited to lead (Pb) in some solders. This is extremely stable in normal use and the EFUP is taken as 50 years, by comparison with the EFUP given for Digital Exchange/Switching Platform in equipment in Appendix A of “General Rule of Environment-Friendly Use Period of Electronic Information Products”. This is indicated by the product marking:

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 19 50 It is assumed that while the product is in normal use, any batteries associated with real-time clocks or battery-backed RAM will be replaced at the regular intervals. The EFUP relates only to the environmental impact of the product in normal use, it does not imply that the product will continue to be supported for 50 years. Recycling information Network Electronics provides assistance to customers and recyclers through our web site http://www.network-electronics.com. Please contact Network Electronics’ Customer Support for assistance with recycling if this site does not show the information you require. Where it is not possible to return the product to Network Electronics or its agents for recycling, the following general information may be of assistance: Before attempting disassembly, ensure the product is completely disconnected from power and signal connections. All major parts are marked or labelled to show their material content. Depending on the date of manufacture, this product may contain lead in solder. Some circuit boards may contain battery-backed memory devices.

DATE: 23 July 2008

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 20 EC Declaration of Conformity MANUFACTURER Network Electronics AS P.B. 1020, N-3204 SANDEFJORD, Norway AUTHORISED REPRESENTATIVE (Established within the EEA) Not applicable MODEL NUMBER(S) ADC-SDI-CC DESCRIPTION Component and Composite Analogue Video Converter DIRECTIVES this equipment complies with LVD 73/23/EEC EMC 2004/108/EEC HARMONISED STANDARDS applied in order to verify compliance with Directive(s) EN 55103-1:1996 EN 55103-2:1996 TEST REPORTS ISSUED BY Notified/Competent Body Report no: Nemko E07379.00 TECHNICAL CONSTRUCTION FILE NO Not applicable YEAR WHICH THE CE-MARK WAS AFFIXED 2008 TEST AUTHORIZED SIGNATORY MANUFACTURER AUTHORISED REPRESENTATIVE (Established within EEA) Date of Issue 2008-07-14 Place of Issue Not applicable Sandefjord, Norway Name Thomas Øhrbom Position Quality Manager (authorised signature)

Other Media Converter Manuals