Text of the manual

Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98

E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 1 USER MANUAL HD-EO High Definition Electrical to Optical Converter Network Electronics ASA Thorøya N-3204 Sandefjord, Norway Phone: +47 33 48 99 99 Fax: +47 33 48 99 98 e-mail: [email protected] www.network-electronics.com

DATE: 13 August 2002

Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 2 Revision history The latest version is always available in pdf-format on our web-site: http://www.network-electronics.com/ Current revision of this document is the uppermost in the table below. Revision Replaces Date Change Description B A 13.08.02 Printing errors A 09.08.02 Preliminary version

DATE: 13 August 2002

Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 3 Index 1. General......................................................................................................................................................4 2. Specifications............................................................................................................................................5 3. Format Configuration .............................................................................................................................7 4. Connector module....................................................................................................................................8 4.1 Mounting the connector module. .........................................................................................................8 4.2 Terminal format support......................................................................................................................9 5. Module status ...........................................................................................................................................9 5.1 GPI ALARM – Module Status Outputs..............................................................................................10 4.2 Front Panel - Status Monitoring........................................................................................................11 6. Laser safety precautions........................................................................................................................12 Declaration of conformity with CE..........................................................................................................13 General environmental requirements for Network flashlink® equipment...........................................13

DATE: 13 August 2002

Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 4 1. General The flashlink  HD-EO is a multi bit-rate electrical to optical converter module providing high performance media conversion for various signal formats from 19.4Mbps up to 1485Mbps. This state of the art unit offers Fabry-Perot laser technology with long wavelength on single mode fiber. Unmatched signal accuracy, even in critical applications with pathological signal patterns makes the HD-EO the first choice for all optical transport demands. The HD-EO can transport all HD and SD signal formats in addition to DVB-ASI and SMPTE 310. It can also perform signal reclocking, which is selectable on application. The optical output comes with a sophisticated 1310nm F-P laser covering the demands of short and medium haul applications. The open system platform of Network Electronics flashlink  system allows easy interoperability with third party fiber optical systems. The electrical input is equipped with a multi rate cable equaliser providing an equalisation of typically 100m of high quality coax cable at 1485Mbps. A distribution amplifier with 2 outputs reduces the need for additional DA’s (for DVB-ASI only one can be used). Figure 1 - HD-EO – HD-SDI Electrical to Optical Converter for 1310nm

DATE: 13 August 2002

Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 5 2. Specifications Optical Output Transmission circuit fiber: Single Mode Light source: F-P laser Optical power: -7.5dBm or –3dBm @1310nm 0dBm @ 1550nm (DFB laser) Optical centre wavelength: 1310nm or 1550nm Max. wavelength drift: +/- 20nm @ temp. range: 0 to +50 °C Jitter (UI=Unit Interval): 0.135 UI max. @ 270Mbps 0.2 UI max. @ 1485Mbps Connector return loss: >40dB w/SM fiber Maximum reflected power: 4% Connector: SC/UPC Electrical Power: +5V DC / 3W Max. Control: Control system for access to setup and module status with BITE (Built-In Test Equipment) Electrical Input Data rate NRZ: 19.4 to 1485 Mbps Equalisation: Automatic Cable equaliser and reclocker can be bypassed to support bitrates down to 2Mbps. Impedance: 75 ohm Return loss: >15dB @ 1485MHz Signal level: nom. 800mV Connector: BNC Electrical Output Number of outputs: 2 Connector: BNC Impedance: 75 ohm Return loss: >15dB @ 1485MHz Jitter: max 0.2UI Peak to peak signal level: 0.8V ± 0.1V Signal polarity: 1 non inverting, 1 inverting

DATE: 13 August 2002

Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 6 Standards Supported standards for electrical and optical ports: SMPTE: SMPTE 292, SMPTE259M, SMPTE297, SMPTE305M, SMPTE310, DVB-ASI: EN50083-9 HD-EO available in 3 versions: Part number Wavelength Laser type Output power HD-EO-13T -7.5dBm HD-EO-13T -3dBm HD-EO-15T 0dBm 1310nm 1310nm 1550nm F-P F-P DFB -7.5dBm -3dBm 0dBm

DATE: 13 August 2002

Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 7 3. Format Configuration The HD-EO can support a number of different broadcast formats. The correct configuration can either be set with a DIP switch or with the GYDA Control System. The layout of HD-EO is shown in the drawing below with the DIP switch to the upper left position. Figure 2 - HD-EO-13T board layout. DIP switch configuration must be set according to the table below: Switch # Label Function DIP=ON Function DIP=OFF Comment 1 D/B Not in use Not in use Always in broadcast mode 2 E/O Not in use Not in use Always E to O mode 3 RCL Reclocker ON Reclocker Bypass Reclocker mode 4 EQ Cable equaliser ON Cable equaliser Bypass Equaliser mode 5 ASI DVB-ASI Reclocker support SDI 177Mbps Reclocker support Select ASI or 177Mbps support 6 GBE Not in use Not in use 7 622 Not in use Not in use 8 OVR Override GYDA control Config. with DIP switch GYDA control Config. with GYDA Select configuration from GYDA All DIP switches are off when pointing towards the release handle. All clock rates for HD-SDI, SDI and DVB-ASI are automatically configured by the module itself.

DATE: 13 August 2002

Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 8 4. Connector module The HD-EO has a dedicated connector module: SDI-C1 (Rev.1 or later). This module is mounted at the rear of the sub-rack. The module is shown in figure 3. Figure 3 - Overview of the SDI-C1 connector module In typical use a HD-EO / HD-OE module at each end will be used. The electrical input signal is connected to the DIGITAL INPUT BNC on the transmitting HD-EO, and the electrical output is connected to the DIGITAL OUTPUT 1 or DIGITAL OUTPUT 2 BNC on the receiving HD-OE. The fiber cable is connected to the OPTICAL ports on HD-EO and HD-OE. Please note that DIGITAL OUTPUT 2 has an inverted signal, so formats like DVB-ASI can not use be used on this output. 4.1 Mounting the connector module. The details of how the connector module is mounted, is found in the user manual for the sub-rack frame FR-2RU-10-2. This manual is also available from our web site: http://www.network-electronics.com/

DATE: 13 August 2002

Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 9 4.2 Terminal format support The different input and output ports on HD-EO can support a number of formats. The table below shows which signal formats are supported on the selected terminals. Terminal format support: Terminal Function Supported Format Mode DIGITAL INPUT Electrical Input HD-SDI, SDI, DVB-ASI, SMPTE310, Transparent* Input DIGITAL OUTPUT 1 Electrical Output – None inverted Reclocked DA output HD-SDI, SDI, DVB-ASI, SMPTE310, Transparent* Output DIGITAL OUTPUT 2 Electrical Output – Inverted Reclocked DA output HD-SDI, SDI, Transparent* Output OPTICAL Optical Output (Transmitter) HD-SDI, SDI, DVB-ASI, SMPTE310, Transparent* Output GPI ALARM Open Collector Alarms Wired alarms OC Output * HD-EO has a “Transparent mode”. In this mode all reclockers are switched off and no jitter attenuation will be performed. This mode may be used for non-standard or unsupported bit rates over shorter distances and up to 1 Gbps. 5. Module status The status of the module can be monitored in three ways. 1. GYDA System Controller (optional). 2. GPI at the rear of the sub-rack. 3. LED’s at the front of the sub-rack. Of these three, the GPI and the LED’s are mounted on the module itself, whereas the GYDA System Controller is a separate module giving detailed information on the card status. The functions of the GPI and the LED’s are described in sections 5.1 and 5.2. The GYDA controller is described in a separate user manual.

DATE: 13 August 2002

Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 10 5.1 GPI ALARM – Module Status Outputs These outputs can be used for wiring up alarms for third party control systems. The GPI outputs are open collector outputs, sinking to ground when an alarm is triggered. The GPI connector is shown in figure 4. Electrical Maximums for GPI outputs Max current: 100mA Max voltage: 30V MR-TR module GPI pinning: Signal Name Pin # Mode Status General error status for the module. Pin 1 Open Collector Laser Fail Laser Fail Alarm Pin 2 Open Collector LOS Los Of Signal Pin 3 Open Collector LOCK Reclocker out of Lock Pin 4 Open Collector Ground 0 volt pin Pin 8 0V. Figure 4 - GPI Outlet

DATE: 13 August 2002

Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 11 5.2 Front Panel - Status Monitoring The status of the module can be easily monitored visually by the LED’s at the front of the module. The LED’s are visible through the front panel as shown in figure 5 below. (Text not printed on the front panel). Figure 5 - Front panel indicator overview for HD-EO The HD-EO has 4 LED’s each showing a status corresponding to the GPI pinning. The position of the different LED’s is shown in figure 5. Diode \ state Red LED Green LED No light Status Module is faulty, or module is initialising. Module is OK Module power is OK Module has no power Laser fail Laser is malfunctioning and the APC can no longer keep the output power within range. Laser is OK LOS Loss of signal No electrical input signal. Electrical input signal Present LOCK Re-clocker is out of lock Re-clocker is in lock on a supported signal format

DATE: 13 August 2002

Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 12 6. Laser safety precautions Guidelines to limit hazards from laser exposure. All the available EO units in the flashlink range include a laser. Therefore this note on laser safety should be read thoroughly. The lasers emit light at wavelengths around 1310 nm or 1550 nm. This means that the human eye cannot see the beam, and the blink reflex can not protect the eye. (The human eye can see light between 400 nm to 700 nm). A laser beam can be harmful to the human eye (depending on laser power and exposure time). Therefore: !! BE CAREFUL WHEN CONNECTING / DISCONNECTING FIBER PIGTAILS (ENDS). NEVER LOOK DIRECTLY INTO THE PIGTAIL OF THE LASER/FIBER. NEVER USE MICROSCOPES, MAGNIFYING GLASSES OR EYE LOUPES TO LOOK INTO A FIBER END. USE LASER SAFETY GOGGLES BLOCKING LIGHT AT 1310 nm AND AT 1550 nm Instruments exist to verify light output power: Power meters, IR-cards etc. flashlink features: All the laser module cards in the flashlink product range, are Class 1 laser products according to IEC 825-1 1993, and class I according to 21 CFR 1040.10 when used in normal operation. More details can be found in the user manual for the FR-2RU-10-2 frame. Maximum output power*: 5 mW. Operating wavelengths: > 1270 nm. *Max power is for safety analysis only and does not represent device performance.

DATE: 13 August 2002

Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 E-mail: [email protected] – Web: http://www.network-electronics.com/ Technical specifications are subject to be changed without notice. 13 Declaration of conformity with CE This apparatus meets the requirements of EN 55103-1 (November 1996) with regard to emissions, and EN 55103-2 (November 1996) with regard to immunity; it thereby complies with the Electromagnetic Compatibility Directive 89/336/EEC. General environmental requirements for Network flashlink® equipment 1. The equipment will meet the guaranteed performance specification under the following environmental conditions: • Operating room temperature range 0°C to 40°C • Operating relative humidity range up to 90% (non-condensing) 2. The equipment will operate without damage under the following environmental conditions: • Temperature range -10°C to 50°C • Relative humidity range up to 95% (non-condensing) 3. Electromagnetic compatibility conditions: • Emissions EN 55103-1 (Directive 89/336/EEC) • Immunity EN 55103-2 (Directive 89/336/EEC)