Network Electronics HD-EO Operation & User’s Manual
Read Online
Read the Network Electronics HD-EO Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98
E-mail: [email protected] – Web: http://www.network-electronics.com/
Technical specifications are subject to be changed without notice.
1
USER MANUAL
HD-EO
High Definition Electrical to Optical Converter
Network Electronics ASA
Thorøya
N-3204 Sandefjord, Norway
Phone: +47 33 48 99 99
Fax: +47 33 48 99 98
e-mail: [email protected]
www.network-electronics.com
DATE: 13 August 2002
Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98
E-mail: [email protected] – Web: http://www.network-electronics.com/
Technical specifications are subject to be changed without notice.
2
Revision history
The latest version is always available in pdf-format on our web-site:
http://www.network-electronics.com/
Current revision of this document is the uppermost in the table below.
Revision
Replaces Date
Change Description
B
A
13.08.02
Printing errors
A
09.08.02
Preliminary version
DATE: 13 August 2002
Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98
E-mail: [email protected] – Web: http://www.network-electronics.com/
Technical specifications are subject to be changed without notice.
3
Index
1. General......................................................................................................................................................4
2. Specifications............................................................................................................................................5
3. Format Configuration .............................................................................................................................7
4. Connector module....................................................................................................................................8
4.1 Mounting the connector module. .........................................................................................................8
4.2 Terminal format support......................................................................................................................9
5. Module status ...........................................................................................................................................9
5.1 GPI ALARM – Module Status Outputs..............................................................................................10
4.2 Front Panel - Status Monitoring........................................................................................................11
6. Laser safety precautions........................................................................................................................12
Declaration of conformity with CE..........................................................................................................13
General environmental requirements for Network flashlink® equipment...........................................13
DATE: 13 August 2002
Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98
E-mail: [email protected] – Web: http://www.network-electronics.com/
Technical specifications are subject to be changed without notice.
4
1. General
The flashlink HD-EO is a multi bit-rate electrical to optical converter module providing high
performance media conversion for various signal formats from 19.4Mbps up to 1485Mbps. This state of
the art unit offers Fabry-Perot laser technology with long wavelength on single mode fiber. Unmatched
signal accuracy, even in critical applications with pathological signal patterns makes the HD-EO the first
choice for all optical transport demands.
The HD-EO can transport all HD and SD signal formats in addition to DVB-ASI and SMPTE 310. It can
also perform signal reclocking, which is selectable on application. The optical output comes with a
sophisticated 1310nm F-P laser covering the demands of short and medium haul applications. The open
system platform of Network Electronics flashlink system allows easy interoperability with third party
fiber optical systems.
The electrical input is equipped with a multi rate cable equaliser providing an equalisation of typically
100m of high quality coax cable at 1485Mbps. A distribution amplifier with 2 outputs reduces the need
for additional DA’s (for DVB-ASI only one can be used).
Figure 1 - HD-EO – HD-SDI Electrical to Optical Converter for 1310nm
DATE: 13 August 2002
Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98
E-mail: [email protected] – Web: http://www.network-electronics.com/
Technical specifications are subject to be changed without notice.
5
2. Specifications
Optical Output
Transmission circuit fiber:
Single Mode
Light source:
F-P laser
Optical power:
-7.5dBm or –3dBm @1310nm
0dBm @ 1550nm (DFB laser)
Optical centre wavelength:
1310nm or 1550nm
Max. wavelength drift:
+/- 20nm @
temp. range:
0 to +50 °C
Jitter (UI=Unit Interval):
0.135 UI max. @ 270Mbps
0.2 UI max. @ 1485Mbps
Connector return loss:
>40dB w/SM fiber
Maximum reflected power:
4%
Connector:
SC/UPC
Electrical
Power:
+5V DC / 3W Max.
Control:
Control system for access to setup and module status
with BITE (Built-In Test Equipment)
Electrical Input
Data rate NRZ:
19.4 to 1485 Mbps
Equalisation:
Automatic
Cable equaliser and reclocker can be bypassed to
support bitrates down to 2Mbps.
Impedance:
75 ohm
Return loss:
>15dB @ 1485MHz
Signal level:
nom. 800mV
Connector:
BNC
Electrical Output
Number of outputs:
2
Connector:
BNC
Impedance:
75 ohm
Return loss:
>15dB @ 1485MHz
Jitter:
max 0.2UI
Peak to peak signal level:
0.8V ± 0.1V
Signal polarity:
1 non inverting,
1 inverting
DATE: 13 August 2002
Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98
E-mail: [email protected] – Web: http://www.network-electronics.com/
Technical specifications are subject to be changed without notice.
6
Standards
Supported standards for electrical and optical ports:
SMPTE:
SMPTE 292, SMPTE259M, SMPTE297,
SMPTE305M, SMPTE310,
DVB-ASI:
EN50083-9
HD-EO available in 3 versions:
Part number
Wavelength
Laser type
Output power
HD-EO-13T -7.5dBm
HD-EO-13T -3dBm
HD-EO-15T 0dBm
1310nm
1310nm
1550nm
F-P
F-P
DFB
-7.5dBm
-3dBm
0dBm
DATE: 13 August 2002
Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98
E-mail: [email protected] – Web: http://www.network-electronics.com/
Technical specifications are subject to be changed without notice.
7
3. Format Configuration
The HD-EO can support a number of different broadcast formats. The correct configuration can either be
set with a DIP switch or with the GYDA Control System. The layout of HD-EO is shown in the drawing
below with the DIP switch to the upper left position.
Figure 2 - HD-EO-13T board layout.
DIP switch configuration must be set according to the table below:
Switch # Label
Function DIP=ON
Function DIP=OFF
Comment
1
D/B
Not in use
Not in use
Always in broadcast mode
2
E/O
Not in use
Not in use
Always E to O mode
3
RCL
Reclocker ON
Reclocker Bypass
Reclocker mode
4
EQ
Cable equaliser ON
Cable equaliser Bypass
Equaliser mode
5
ASI
DVB-ASI Reclocker
support
SDI 177Mbps Reclocker
support
Select ASI or 177Mbps
support
6
GBE
Not in use
Not in use
7
622
Not in use
Not in use
8
OVR
Override GYDA control
Config. with DIP switch
GYDA control
Config. with GYDA
Select configuration from
GYDA
All DIP switches are off when pointing towards the release handle.
All clock rates for HD-SDI, SDI and DVB-ASI are automatically configured by the module itself.
DATE: 13 August 2002
Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98
E-mail: [email protected] – Web: http://www.network-electronics.com/
Technical specifications are subject to be changed without notice.
8
4. Connector module
The HD-EO has a dedicated connector module: SDI-C1 (Rev.1 or later). This module is mounted at the
rear of the sub-rack. The module is shown in figure 3.
Figure 3 - Overview of the SDI-C1 connector module
In typical use a HD-EO / HD-OE module at each end will be used. The electrical input signal is connected
to the DIGITAL INPUT BNC on the transmitting HD-EO, and the electrical output is connected to the
DIGITAL OUTPUT 1 or DIGITAL OUTPUT 2 BNC on the receiving HD-OE. The fiber cable is
connected to the OPTICAL ports on HD-EO and HD-OE. Please note that DIGITAL OUTPUT 2 has an
inverted signal, so formats like DVB-ASI can not use be used on this output.
4.1 Mounting the connector module.
The details of how the connector module is mounted, is found in the user manual for the sub-rack frame
FR-2RU-10-2.
This manual is also available from our web site: http://www.network-electronics.com/
DATE: 13 August 2002
Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98
E-mail: [email protected] – Web: http://www.network-electronics.com/
Technical specifications are subject to be changed without notice.
9
4.2 Terminal format support
The different input and output ports on HD-EO can support a number of formats. The table below shows
which signal formats are supported on the selected terminals.
Terminal format support:
Terminal
Function
Supported Format
Mode
DIGITAL
INPUT
Electrical Input
HD-SDI, SDI, DVB-ASI,
SMPTE310, Transparent*
Input
DIGITAL
OUTPUT 1
Electrical Output – None inverted
Reclocked DA output
HD-SDI, SDI, DVB-ASI,
SMPTE310, Transparent*
Output
DIGITAL
OUTPUT 2
Electrical Output – Inverted
Reclocked DA output
HD-SDI, SDI, Transparent*
Output
OPTICAL
Optical Output (Transmitter)
HD-SDI, SDI, DVB-ASI,
SMPTE310, Transparent*
Output
GPI ALARM Open Collector Alarms
Wired alarms
OC
Output
* HD-EO has a “Transparent mode”. In this mode all reclockers are switched off and no jitter attenuation
will be performed. This mode may be used for non-standard or unsupported bit rates over shorter
distances and up to 1 Gbps.
5. Module status
The status of the module can be monitored in three ways.
1. GYDA System Controller (optional).
2. GPI at the rear of the sub-rack.
3. LED’s at the front of the sub-rack.
Of these three, the GPI and the LED’s are mounted on the module itself, whereas the GYDA System
Controller is a separate module giving detailed information on the card status. The functions of the GPI
and the LED’s are described in sections 5.1 and 5.2. The GYDA controller is described in a separate user
manual.
DATE: 13 August 2002
Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98
E-mail: [email protected] – Web: http://www.network-electronics.com/
Technical specifications are subject to be changed without notice.
10
5.1 GPI ALARM – Module Status Outputs
These outputs can be used for wiring up alarms for third party control systems. The GPI outputs are open
collector outputs, sinking to ground when an alarm is triggered. The GPI connector is shown in figure 4.
Electrical Maximums for GPI outputs
Max current: 100mA
Max voltage: 30V
MR-TR module GPI pinning:
Signal
Name
Pin # Mode
Status
General error status for the module.
Pin 1
Open Collector
Laser Fail
Laser Fail Alarm
Pin 2
Open Collector
LOS
Los Of Signal
Pin 3
Open Collector
LOCK
Reclocker out of Lock
Pin 4
Open Collector
Ground
0 volt pin
Pin 8
0V.
Figure 4 - GPI Outlet
DATE: 13 August 2002
Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98
E-mail: [email protected] – Web: http://www.network-electronics.com/
Technical specifications are subject to be changed without notice.
11
5.2 Front Panel - Status Monitoring
The status of the module can be easily monitored visually by the LED’s at the front of the module. The
LED’s are visible through the front panel as shown in figure 5 below.
(Text not printed on the front panel).
Figure 5 - Front panel indicator overview for HD-EO
The HD-EO has 4 LED’s each showing a status corresponding to the GPI pinning. The position of the
different LED’s is shown in figure 5.
Diode \ state
Red LED
Green LED
No light
Status
Module is faulty, or module
is initialising.
Module is OK
Module power is OK
Module has no
power
Laser fail
Laser is malfunctioning and
the APC can no longer keep
the output power within
range.
Laser is OK
LOS
Loss of signal
No electrical input signal.
Electrical input signal
Present
LOCK
Re-clocker is out of lock
Re-clocker is in lock on
a supported signal format
DATE: 13 August 2002
Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98
E-mail: [email protected] – Web: http://www.network-electronics.com/
Technical specifications are subject to be changed without notice.
12
6. Laser safety precautions
Guidelines to limit hazards from laser exposure.
All the available EO units in the flashlink range include a laser.
Therefore this note on laser safety should be read thoroughly.
The lasers emit light at wavelengths around 1310 nm or 1550 nm. This means that the human eye cannot
see the beam, and the blink reflex can not protect the eye. (The human eye can see light between 400 nm
to 700 nm).
A laser beam can be harmful to the human eye (depending on laser power and exposure time). Therefore:
!! BE CAREFUL WHEN CONNECTING / DISCONNECTING FIBER PIGTAILS (ENDS).
NEVER LOOK DIRECTLY INTO THE PIGTAIL OF THE LASER/FIBER.
NEVER USE MICROSCOPES, MAGNIFYING GLASSES OR EYE LOUPES TO LOOK INTO A
FIBER END.
USE LASER SAFETY GOGGLES BLOCKING LIGHT AT 1310 nm AND AT 1550 nm
Instruments exist to verify light output power: Power meters, IR-cards etc.
flashlink features:
All the laser module cards in the flashlink product range, are Class 1 laser products according to
IEC 825-1 1993, and class I according to 21 CFR 1040.10 when used in normal operation.
More details can be found in the user manual for the FR-2RU-10-2 frame.
Maximum output power*: 5 mW.
Operating wavelengths: > 1270 nm.
*Max power is for safety analysis only and does not represent device performance.
DATE: 13 August 2002
Network Electronics ASA, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98
E-mail: [email protected] – Web: http://www.network-electronics.com/
Technical specifications are subject to be changed without notice.
13
Declaration of conformity with CE
This apparatus meets the requirements of EN 55103-1 (November 1996) with regard to emissions, and
EN 55103-2 (November 1996) with regard to immunity; it thereby complies with the Electromagnetic
Compatibility Directive 89/336/EEC.
General environmental requirements for Network flashlink® equipment
1. The equipment will meet the guaranteed performance specification under the following environmental
conditions:
• Operating room temperature range
0°C to 40°C
• Operating relative humidity range
up to 90% (non-condensing)
2. The equipment will operate without damage under the following environmental conditions:
• Temperature range
-10°C to 50°C
• Relative humidity range
up to 95% (non-condensing)
3. Electromagnetic compatibility conditions:
• Emissions
EN 55103-1
(Directive 89/336/EEC)
• Immunity
EN 55103-2
(Directive 89/336/EEC)