The CS120 is aceiling mounted IR sensor designed

for use with the Niles infrared extender systems. Installed in aremote room location, the CS120 receives the IR commands transmitted from your existing hand-held remotes in that room. The commands are carried via acategory 5 cable to your AN equipment in another room, and instantly "repeated". The CS120 is compatible with all current Niles infrared systems. It may be used along with, or as an alternative to, the Niles TS120, MS120, MS220, WS120R and MVC100lR sensors or the IntelliPad®. The CS120 is just one part of the three building blocks necessary to complete aNiles IR repeating system • IR Main System Unit-Models MSU140, MSU250, MSU480 and MSU440Z • IR Sensors/Keypads-Models WS120R, TS120, MS120, MS220, CS120 and the IntelliPad • IR Flashers-Models MF1 , MF2, MF1 VF, MF2VF and the IRB1 An IR sensor expansion hUb, Model IRH610, is available to provide additional sensor inputs to your system. 1 FEATURES & BENEFITS The CS120 offers a number of improvements over other miniature IR sensors. • Wideband High-Fidelity Design enables operation with virtually any brand ofequipment • Patent Pending Universal Noise Suppression en- ables operation in virtually any environment: near plasma and LCD displays, compact fluorescent lights, and indirect sunlight • Excellent IR receiving range - 20' to 35' of remote control range (depending upon the strength ofyour handheld remote) • Factory tested for pickup range and angle • Small size ofonly 1/2" diameter by 2-7/8" long-fits almost anywhere • 10' ofconnecting wire included • Printed circuit board design uses surface mount technology, assuring high reliability • Ideal for both home and commercial installations • Each CS120 includes a transparent cover • Two year parts and labor limited warranty 2

IMPORTANT: REFER INSTALLATION TO APROFES-

SIONAL CUSTOM INSTALLER IF YOU ARE UNFAMIL- 1AR WITH ANY OF THE FOLLOWING PROCEDURES. TOOLS REQUIRED • 1/8" Standard Slotted Screwdriver • 1/4"Standard Slotted Screwdriver • Wire Stripper Type of Cable The CS120 connects to the Niles Infrared main sys- tems unit or IRH610 sensor expansion hub with an individual home run of CAT-5 cable. When running wires inside walls, most states and municipalities in the U.S. specify that you must use a special type of wire. Usually, the requirement is that the wire has a specific "CL" fire rating, such as "CL-2" or "CL-3". Consult your Niles dealer, building contrac- tor, or local building and inspection department if unsure about which type of wire is best for your application. CS120 Mounting Location The CS120 is designed to be ceiling mounted in a direct line of sight location within the operating range of the remote control. Receiving Range and Pickup Angle The receiving range of the CS120 will vary accord- ing to the IR output strength of the remote control being used. Remote strength varies among brands depending on the number and size of batteries 3 used, and how many IR emitters the remote has. For example, remotes that operate on two small AAA batteries and have only one IR emitter are generally not as strong as remotes that use the larger AA size batteries and have two emitters. Tests with various manufacturers' remote controls have shown that the operating range can vary from a minimum of 20' to a maximum of about 35'. Infrared signals travel essentially line-of-sight. They will not pass through or around solid objects. Do not rely on an IR signal being able to "bounce" off awall or object to the CS120. The IR pickup angle of the CS120 is 30° off-axis (horizontal and vertical) at 25'. Avoiding Interference CS120 is designed to work in most applications including with LCD and plasma displays and in areas where CFL lighting and indirect sunlight are present. You should avoid locating the CS120 near potential sources of electrical or optical noise, such as light dimmers or low-voltage lights. Avoiding Optical Feedback If installing the CS120 in the same room as an IR flasher, it is possible for the flasher's IR output to be picked-up by the CS120. This effect, known as an optical feedback loop, can cause erratic operation. Optical feedback is similar to acoustical feedback: the howling or whistling sound heard in a P.A. system when the microphone is too close to the speaker. 4

To avoid optical feedback:

1. Re-position the f1asher(s) and/or the sensor 2. Use Niles an MF1 or MF2 Microflasher and cover them with the supplied IR blockers Using the CS120 with the Niles Multilane keypads with an IR connection The CS120 is fully compatible with Niles MultiZone keypads with an IR connection, follow the wiring instructions in Figure 5. For specific information see your Niles MultiZone keypad manual. INSTALLATION If you are installing the CS120 into an existing ceiling, take time to consider any possible obstruc- tions which may be hidden, such as wood or metal studs, electrical, telephone or other types of wiring, plumbing, AC or heating conduits, etc. 1. Determine a mounting location for the CS120 2. Drill a 11/16" hole where the CS120 will be mounted 3. Run the CS120's IR cable. Label the cable for future reference (Figure 2). The CS120 is sup- plied with 10' ofpre-stripped IR cable. The IR ca- ble may be shortened or lengthened as needed. Ifyou want to make the CS120's cable shorter, use apairof wire cutters to cut the cable to the desired length. The IR cable may be lengthened 5 by splicing it to arecommended IR cable (See Installation Considerations-Type of Cable). You may splice the CS120 cable to anothercable by soldering or crimping the connections. 4. Fasten sensor to ceiling with supplied screws (Figure 3) 5. Connect the CS120 cable to the main system unit (Figure 1). Strip 1/4"ofinsulation from the end ofeach wire. Tightly twist the end ofeach wire until there are no frayed ends. Insert each wire into the appropriate hole on the removable connector plug, and snap the locking tab down. To help you, the connector plug is keyed. Insert the smooth side of the connector plug into the smooth side of the socket. Don't force the scalloped side of the connector plug into the smooth side of the socket. Refer to the main system main system unit manual for specific installation instrutions. 6

Power, IR data, status signal and ground

via CAT-5 wire Wiring diagram (installed in an MSU250 system) CS120 IR sensor 12V DC Power supply (not supplied) plugged into the switched outlet. Niles stock# FG01035 Stereo receiver MSU250 +lZV DC FLASKII OUTPUTS 6 _NILES ..~ Msuno III M41N nm... UNO lOW Niles IR flasher I ~----~ 12V DC power supply (supplied with the MSU250 main system unit) plugged into an unswitched AC outlet powers the system Figure 1 Red =12V+ Black = Ground Yellow = Data White = Status Figure 2 Wiring legend 7 8

Figure 3 Parts guide

(a) Mounting surface (b) IR Cable (10 feet supplied) (c) CS120 Miniature IR Sensor (supplied) (d) Installation screws (supplied) (e) CS120 lens bezel (supplied) Figure 4 Removing the bezel Figure 5 Suggested wiring of CS120 to Niles MultiZone Keypad that has an IR-Sensor connection 9 Tab Down _f£-I~--jl 5 = STATUS 3 = GROUND 1=12V 2= DATA 1 = Green/White - 12V 2 = Green - DATA 3 = Orange/White - GROUND 4 = Blue· EMPTY 5 = Blue/White· STATUS 6 = Orange - EMPTY 7 = Brown/White - EMPTY 8 = Brown - EMPTY 10

Operation of the CS120 is straightforward. Simply

aim your hand-held remote at the CS120. Your IR command is instantly repeated to your AN equip- ment. TROUBLESHOOTING This manual contains instructions for the CS120 only. For specific information on the adjustment and operation of your Niles infrared extender sys- tem, please refer to the instruction manual included with your Niles IR main system unit (MSU140, MSU250,MSU480,MSU440~. 1. Test the remote control(s) by operating the AN equipment directly. Replace the batteries if needed 2. Double check the cable connections on the CS120 and on the main system unit. Look for open, shorted or reversed wires (Figure 2) 3. Test for interference from the following sources: • Neon, Compact Florescent Lighting (CFL), or halogen lights in the room • Light dimmers, beginning with those closest to the CS120 Observe the main system unit IR confirmation LED while performing all the tests. It is possible to have interference from more than one source. Eliminating Optical Feedback In some installations, two conditions combine to 11 create an optical feedback loop. Symptoms can include: poor range, intermittent operation or no operation.The conditions which sometimes combine to create afeedback loop are: 1. Both asensor and aflasher are located within the same room 2. There is some low-level noise or interference on your system You can eliminate optical feedback by replacing any IRB1 "flooding flasher" with an MF1 or MF2 MicroFlasher® and covering all flashers with the supplied IR blocking covers. EMI (Electromagnetic Interference) Identity the source of the interference. The most common sources of electromagnetic interference are listed in the Installation Considerations section. To eliminate EMI try the following methods: 1. Move the sensor or the sensor cable away from the EMI source or move the source of the EMI away from the sensor or the cable 2. Connect the Sensor's GND terminal to true earth ground (if this isn't feasible use the main system unit's GND terminal) There are many methods for reducing interference. Which solution is best for you depends on your situation. If you require further assistance call Niles Technical Support at 305-238-4373 or 1-800-289-4434 (M-F 8:00 AM - 7:00PM ED. You can also email Niles Technical Support at [email protected]. 12

Compatible with virtually all brands of remotes

using carrier frequencies between 25kHz and 90kHz IR Receiving Range Varies depending on remote strength; Typically 20' to 35 1 (6.09 mx 10.67 m) IR Receiving Angle 30° off-axis (horizontal and vertical) at 25 1 (7.62 m) Mounting Thru-hole, fits into a 11/16 11 diameter hole; requires a minimum of 2-7/8" mounting depth Wiring Requirements Individual home-runs of CAT-5 cable Unit Dimensions Front Bezel: 3/4" (1.90 em) Diameter x 1/4" (.64 em) high Lens Bezel: 1-1/2 11 (3.81 em) Diameter x 41/64" high (1.63 em) Unit With Dome: 1/2" (1.27 em) Diameter x3" (7.62 em) Long Unit Without Dome: 1/2" (1.27 em) Diameter x2-7/8" (7.30 em) Long Contents • CS120 Miniature IR Sensor • CS120 Lens Bezel • Installation Screws (3) • Mounting Bracket 13

NILES AUDIO CORPORATION ("NILES") WARRANTS ITS ACTIVE PRODUCTS

(THOSE NOT REQUIRING AC OR BATTERY POWER) TO THE ORIGINAL PURCHASER TO BE FREE OF MANUFACTURING DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF TWO YEARS FROM DATE OF PURCHASE. THIS WARRANTY IS SUBJECT TO THE FOLLOWING ADDITIONAL CONDITIONS AND LIMITATIONS. THE WARRANTY IS VOID AND INAPPLICABLE IF NILES DEEMS THAT THE PRODUCT HAS BEEN USED OR HANDLED OTHER THAN IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED BY THE MANUFACTURER, INCLUDING BUT NOT LIMITED TO DAMAGE CAUSED BY ACCIDENT, MISHANDLING, IMPROPER INSTALLATION, ABUSE, NEGLIGENCE, OR NORMAL WEAR AND TEAR, OR ANY DEFECT CAUSED BY REPAIR TO THE PRODUCT BY ANYONE OTHER THAN NILES OR AN AUTHORIZED NILES DEALER. TO OBTAIN WARRANTY SERVICE, TAKE THE UNIT TO THE NEAREST AUTHORIZED NILES DEALER, WHO WILL TEST THE PRODUCT AND IF NECESSARY, FORWARD IT TO NILES FOR SERVICE. IF THERE ARE NO AUTHORIZED NILES DEALERS IN YOUR AREA, YOU MUST WRITE TO NILES AND INCLUDE YOUR NAME, MODEL AND SERIAL NUMBER OF YOUR UNIT, ALONG WITH ABRIEF DESCRIPTION OF THE PROBLEM. A FACTORY RETURN AUTHORIZATION NUMBER WILL BE SENT TO YOU. DO NOT RETURN ANY UNIT WITHOUT FIRST RECEIVING WRITTEN AUTHORIZATION AND SHIPPING INSTRUCTIONS FROM NILES. IFTHEABOVE CONDITIONS ARE MET,THE PURCHASER'S SOLE REMEDY SHALL BE TO RETURN THE PRODUCT TO NILES, IN WHICH CASE NILES WILL REPAIR OR REPLACE, AT ITS SOLE OPTION, THE DEFECTIVE PRODUCT WITHOUT CHARGE FOR PARTS OR LABOR. NILES WILL RETURN A UNIT REPAIRED OR REPLACED UNDER WARRANTY BY SHIPPING SAME BY ITS USUAL SHIPPING METHOD FROM THE FACTORY (ONLY) AT ITS EXPENSE WITHIN THE UNITED STATES OF AMERICA. THERE ARE NO OTHER WARRANnE5, INCLUDING WITHOUT UMITAnON, EITHER EXPRESS OR IMPUED WARRANnES OF MERCHANTABILITY OR FITNESS FOR A PARnCULAR PURPOSE, WITH RESPECT TO THE PRODUCT. REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMERIPURCHASER. NILES SHALL NOT BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES EXCEPT TO THE EXTENT PROVIDED (OR PROHIBITED) BY APPUCABLE LAW. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. FOR THE NAME OF YOUR NEAREST AUTHORIZED NILES DEALER CONTACT: NILES AUDIO CORPORATION, P.O. BOX 160818, MIAMI, FLORIDA 33116-0818. Please fill in your product information and retain for your records. MOdel C_S_12_0 Purchase Date _ Serial No. _

Other Racks & Stands Manuals