Text of the manual

For latest product manuals:

omegamanual.info Shop online at User’s Guide

Servicing North America:

U.S.A.: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: [email protected] Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: [email protected] For immediate technical or application assistance: U.S.A. and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA® Customer Service: 1-800-622-2378 / 1-800-622-BEST® Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN® Mexico: En Espan˜ol: (001) 203-359-7803 e-mail: [email protected] FAX: (001) 203-359-7807 [email protected] Servicing Europe: Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands TEL: +31 (0)20 3472121 FAX: +31 (0)20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: [email protected] Czech Republic: Frystatska 184, 733 01 Karviná, Czech Republic TEL: +420 (0)59 6311899 FAX: +420 (0)59 6311114 Toll Free: 0800-1-66342 e-mail: [email protected] France: 11, rue Jacques Cartier, 78280 Guyancourt, France TEL: +33 (0)1 61 37 2900 FAX: +33 (0)1 30 57 5427 Toll Free in France: 0800 466 342 e-mail: [email protected] Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany TEL: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: [email protected] United Kingdom: One Omega Drive, River Bend Technology Centre ISO 9002 Certified Northbank, Irlam, Manchester M44 5BD United Kingdom TEL: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: [email protected] OMEGAnet® Online Service Internet e-mail omega.com [email protected] It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.

Thank you for purchasing the OMEGA RD100B/RD1800B Recorder.

This user’s manual describes the functions of the Ethernet interface and the RS-422A/ 485 communication interface. To ensure correct use, please read this manual thoroughly before beginning operation. After reading the manual, keep it in a convenient location for quick reference whenever a question arises during operation. The following five manuals, including this one, are provided as manuals for the RD100B/ RD1800B Recorder. Please read all of them. The figures used in this manual are mostly of the RD100B. If you are using the RD1800B, refer to the figures for reference. • Paper Manual Manual Title Manual No. Description RD100B Recorder M-4232 Explains the basic operations of the RD100B Operation Guide recorder. RD1800B Recorder M-4243 Explains the basic operations of the RD1800B Operation Guide recorder. • Electronic Manuals Provided on the Accompanying CD-ROM Manual Title Manual No. Description RD100B Recorder M-4231 Explains all the functions and procedures of the User’s Manual RD100B recorder excluding the communication functions. RD1800B Recorder M-4242 Explains all the functions and procedures of the User’s Manual RD1800B recorder excluding the communication functions. RD100B/RD1800B M-4233 This manual. Explains the functions of the Communication Interface Ethernet interface and the RS-422A/485 User’s Manual communication interface. Notes • The contents of this manual are subject to change without prior notice as a result of continuing improvements to the instrument’s performance and functions. The figures given in this manual may differ from those that actually appear on your screen. • Every effort has been made in the preparation of this manual to ensure the accuracy of its contents. However, should you have any questions or find any errors, please contact OMEGA. • Copying or reproducing all or any part of the contents of this manual without permission is strictly prohibited. • The TCP/IP software of this product and the document concerning the TCP/IP software have been developed/created based on the BSD Networking Software, Release 1 that has been licensed from the University of California. Revisions • 1st Edition December 2004 • 2nd Edition March 2005 • 3rd Edition August 2005

Microsoft, MS-DOS, Windows, Windows NT, and Windows XP are either registered

trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. • Adobe, Acrobat, and PostScript are trademarks of Adobe Systems incorporated. • For purposes of this manual, the TM and ® symbols do not accompany their respective trademark names or registered trademark names. • Other company and product names are trademarks or registered trademarks of their respective holders. Functional Enhancement of the RD100B Recorder Functions have been added or modified on the RD100B Recorder since system version 1.11. You can check the system version on the system display. For details, see the RD100B User's Manual (M-4231). Suffix Code Added or Modified Functions Reference Section 4.4: SA command Section 4.4: TD command Section 4.5: XN command Section 4.5: YS command Section 3.2 Section 2.5 (Changed) Expanded the selectable range of alarm values during linear scaling (including 1-5V and SQRT) to −5% to 105% of the scale. (Changed) The procedure to set the start/end date and time of Daylight Saving Time (DST) has been changed. The TD command can be used on the µR20000 and the RD100B with system version 1.11. The SS command can be used on the RD100B with system version 1.02 or earlier. (Added) The print/display format of the date can be changed. (Changed) Modbus slave protocol can be used. Two-wire sstem. (Changed) Users with the same user name cannot be registered. - - - /C3 /C7

How to Use This Manual

Structure of the Manual This user’s manual consists of the following sections. Chapter 1 Overview of the Communication Functions Gives an overview of the communication functions. Chapter 2 Using the Ethernet Interface (/C7 Option) Explains the specifications of the Ethernet interface and how to use the interface. Chapter 3 Using the RS-422A/485 Communication Interface (/C3 Option) Explains the specifications of the RS-422A/485 communication interface and how to use the interface. Chapter 4 Commands Explains each command that is available. Chapter 5 Responses Explains the responses that the recorder returns and the output format of the setup data and measured/computed data. Chapter 6 Status Information Explains the registers that indicate the recorder statuses. Appendix Provides an ASCII character code table, flow charts for outputting data from the recorder, login procedure, and a list of error messages. Index Index of contents.

Conventions Used in This Manual

• Unit • k: Denotes 1000. Example: 5 kg, 100 kHz • K: Denotes 1024. Example: 640 KB • Note The following markings are used in this manual. Improper handling or use can lead to injury to the user or damage to the instrument. This symbol appears on the instrument to indicate that the user must refer to the user’s manual for special instructions. The same symbol appears in the corresponding place in the user’s manual to identify those instructions. In the manual, the symbol is used in conjunction with the word “WARNING” or “CAUTION.” WARNING Calls attention to actions or conditions that could cause serious or fatal injury to the user, and precautions that can be taken to prevent such occurrences. CAUTION Calls attentions to actions or conditions that could cause light injury to the user or damage to the instrument or user’s data, and precautions that can be taken to prevent such occurrences. Note Calls attention to information that is important for proper operation of the instrument. • Bold Characters Bold characters are mainly characters and numbers that appear on the display. • Subheadings On pages that describe the operating procedures in Chapter 2 and 3, the following symbols are used to distinguish the procedures from their explanations. Explanation This subsection describes the setup parameters and the limitations on the procedures. Procedure Follow the numbered steps. All procedures are written with inexperienced users in mind; depending on the operation, not all steps need to be taken. How to Use This Manual

Names of Parts and Basic Key Operations

Display and Keys You use the panel keys and the display to configure the communication functions. For a description of other parts of the recorder, see section 3.1 in the Recorder User’s Manual. (The figure below is of the RD100B Recorder.) Display Front Rear Panel Keys Power switch Optional terminal block RS-422A/485 communication terminals Ethernet port Indicator Keys RCD key Starts/stops recording. MENU key Hold this key down for 3 seconds to enter Setting mode. Hold this key down for 3 seconds also to exit from Setting mode. DISP key Switches the screen in the main display. FUNC key Used when executing manual printout, message printout, etc. DISP MENU key Hold this key down for 3 seconds to switch to the data display setup screen. Hold this key down for 3 seconds also to exit from the data display setup screen. FEED key Feeds the chart paper. CHARACTER Key: Changes the character type when entering a character. Press this key while holding down the SHIFT key to switch the character type in reverse order. UP/DOWN Key: Switches the setup item or the value. Press this key while holding down the SHIFT key to switch the setup item or the value in reverse order. LEFT/RIGHT Key: Moves the cursor to the right when entering a value or character. Press this key while holding down the SHIFT key to move the cursor to the left.. SHIFT Key: Used with the key, key, or the CHARACTER key. ENTER Key: Confirms the setup item or value. CH UP key Switches the displayed channel. (when manual switching is specified) RCD MENU FEED CH UP FUNC MENU DISP 1 CHARACTER ESC/? SHIFT ESC Key: Cancels the operation. When pressed with the SHIFT key, the display of the comment on the setting turns ON/OFF.

Names of Parts and Basic Key Operations

Basic Key Operations This section describes basic operations on the front panel keys to change various settings. • Execution Modes The recorder has the following execution modes. • Operation mode: A mode used to perform recording and monitoring. • Setting mode: A mode used to set the input range, alarms, chart speed, and other parameters. • Basic Setting mode: A mode used to set the basic specifications of functions with the recording operation stopped. * In the explanation of commands in (chapter 4), Run mode collectively refers to Operation mode and Setting mode. Settings related to communications are configured in Basic Setting mode. You cannot enter Basic Setting mode while the recorder is recording or while computation is in progress on the computation function (/M1 option). • Entering Basic Setting Mode Hold down the MENU key for 3 seconds. The Setting mode display appears. Set=Range Input range and s The panel keys are set to the functions marked above the keys as shown below. RCD MENU FEED CH UP FUNC MENU DISP 1 CHARACTER ESC/? SHIFT Hold down both the ( DISP ) key and the ( FUNC ) key for 3 seconds. The Basic Setting mode display appears. The top and bottom lines are the setup item and comment, respectively. The section that is blinking in the setup item that you change. In this manual, the section that you change appears shaded. The comment line shows useful information such as a description of the setup item and the range of selectable values. Read the comment and change the items as necessary. The item to be controlled blinks. Setup item Comment Basic=Alarm Auxiliary alarm • Selecting the Setup Item and Value The selected item change each time you press the ( DISP ) key. The selected item change in reverse order if you press the ( DISP ) while holding down the SHIFT ( FEED ) key. Selections Basic=Ethernet This manual denotes the operation of pressing a key while holding down the SHIFT ( FEED ) key as SHIFT + the other key (for example: SHIFT + key). After you make a selection, press the ( CH UP ) key. The next screen appears. When the Setting Complete screen appears, the changed item is applied. Ethernet host Setting complete • Using the ESC Key If you press the ESC ( 1 MENU ) key, the operation is cancelled, and the display returns to a higher level menu. If you do not show the Setting Complete screen, the changes you made up to that point are discarded. You can show and hide the comment on the bottom line by pressing the ESC ( 1 MENU ) key while holding down the SHIFT ( FEED ) key.

• Entering Values

Use the key or SHIFT + key to move the cursor. Use the key or SHIFT + key to change a digit value. You repeat these steps to enter the value. SHIFT key + key key Target digit A=000.000.000.000 SHIFT key + key key A=000.000.000.000 When you press the key, the change is applied and the next setup item is displayed. • Entering Characters Use the key or SHIFT + key to move the cursor. Use the CHARACTER key or SHIFT + CHARACTER key to select the character type. Use the key or SHIFT + key to select a character. You repeat these steps to set the character string. Select the character type CHARACTER key or SHIFT key + CHARACTER key Cursor Host=ABCDefgh2004 CHR:A-Z The character type changes in the following order: uppercase alphabet, lowercase alphabet, numbers, and symbols. key SHIFT key + key Host=ABCDefgh2004 CHR:A-Z When you press the key, the change is applied and the next screen is displayed. Inserting Characters Press the CHARACTER key or SHIFT + CHARACTER key to show Ins DISP and then press the key. A space for one character is inserted. Enter the character. Deleting a Character Press the CHARACTER key or SHIFT + CHARACTER key to show Del DISP and then press the key. The character is deleted. Deleting an Entire Character String Press the CHARACTER key or SHIFT + CHARACTER key to show Clear DISP and then press the key. The entire character string is deleted. Copying & Pasting a Character String Show the copy source character string. Press the CHARACTER key or SHIFT + CHARACTER key to show Copy DISP and then press the key. The character string is saved to the memory. Show the copy destination. Press the CHARACTER key or SHIFT + CHARACTER key to show Paste DISP and then press the key. The character string is pasted. Names of Parts and Basic Key Operations

• Exiting from Basic Setting Mode

Press the ESC key several times to return to the Basic= screen. Press the key or SHIFT + key to select End and then press the key. The setup save screen appears. Basic=End Save Setting Press the key to select Store and then press the key. The setting is applied and the Operation mode screen appears. If you select Abort and press the key, the setting is discarded and the Operation mode screen appears. End=Store Save settings and Names of Parts and Basic Key Operations

Foreword ......................................................................................................................................... i

Functional Enhancement of the RD100B Recorder ........................................................................ii How to Use This Manual ................................................................................................................ iii Names of Parts and Basic Key Operations .................................................................................... v Chapter 1 Overview of the Communication Functions 1.1 Communication Functions Using the Ethernet Interface (/C7 Option) ............................. 1-1 Functional Construction ................................................................................................... 1-1 Setting/Measurement Server ........................................................................................... 1-1 Maintenance/Test Server ................................................................................................. 1-2 Instrument Information Server ......................................................................................... 1-2 Other Functions ............................................................................................................... 1-3 1.2 Communication Functions Using the RS-422A/485 Communication Interface (/C3 Option) ..................................................................................................................... 1-4 Functional Construction ................................................................................................... 1-4 Setting/Measurement Server ........................................................................................... 1-4 Modbus Slave .................................................................................................................. 1-4 Chapter 2 Using the Ethernet Interface (/C7 Option) 2.1 Ethernet Interface Specifications ..................................................................................... 2-1 Basic Specifications ......................................................................................................... 2-1 The Maximum Number of Simultaneous Connections and the Number of Simultaneous Use ........................................................................................................ 2-1 2.2 Connecting the Ethernet Interface ................................................................................... 2-2 When Connecting Only the Recorder and a PC .............................................................. 2-2 When Connecting to a Preexisting Network .................................................................... 2-2 2.3 Configuring the Ethernet Interface ................................................................................... 2-3 2.4 Checking the Connection Status...................................................................................... 2-7 2.5 Registering Users ............................................................................................................ 2-8 2.6 Setting the Communication Timeout and Keepalive ...................................................... 2-11 Chapter 3 Using the RS-422A/485 Communication Interface (/C3 Option) 3.1 RS-422A/485 Communication Interface Specifications ................................................... 3-1 3.2 Terminal Arrangement and Signal Names and the Connection Procedure of the RS-422A/485 Communication Interface ................................................................ 3-2 Terminal Arrangement and Signal Names ....................................................................... 3-2 Connection Procedure ..................................................................................................... 3-2 Connection Example with a Host Computer .................................................................... 3-3 3.3 The Bit Structure of One Character and the Operation of the Receive Buffer ................. 3-7 The Bit Structure of One Character ................................................................................. 3-7 Receive Buffer and Received Data .................................................................................. 3-7 3.4 Modbus Slave Protocol Specifications ............................................................................. 3-8 Registers .......................................................................................................................... 3-9 Modbus Error Response ................................................................................................ 3-10 3.5 Setting the Serial Interface............................................................................................. 3-11

Chapter 4 Commands

4.1 Command Syntax ............................................................................................................ 4-1 Response ......................................................................................................................... 4-2 4.2 A List of Commands ......................................................................................................... 4-3 Execution Modes and User Levels .................................................................................. 4-3 Setting Commands .......................................................................................................... 4-3 Basic Setting Commands................................................................................................. 4-4 Control Commands .......................................................................................................... 4-5 Output Commands ........................................................................................................... 4-5 RS-422A/485 Dedicated Commands ............................................................................... 4-5 Maintenance/Test Commands ......................................................................................... 4-6 Instrument Information Output Commands ...................................................................... 4-6 4.3 Parameter Values ............................................................................................................ 4-7 Input Range ..................................................................................................................... 4-7 Miscellaneous .................................................................................................................. 4-8 4.4 Setting Commands .................................................................................................................... 4-10 4.5 Basic Setting Commands .......................................................................................................... 4-18 4.6 Control Commands ................................................................................................................... 4-25 4.7 Output Commands .................................................................................................................... 4-26 4.8 RS-422A/485 Dedicated Commands ........................................................................................ 4-28 4.9 Maintenance/Test Commands (Available when using the maintenance/test server function via Ethernet communications) ............................................................... 4-29 4.10 Instrument Information Output Commands (Available when using the instrument information server function via Ethernet communications) ............................................ 4-30 Chapter 5 Responses 5.1 Response Syntax ............................................................................................................. 5-1 Affirmative Response ....................................................................................................... 5-1 Single Negative Response............................................................................................... 5-1 Multiple Negative Responses .......................................................................................... 5-1 ASCII Output .................................................................................................................... 5-2 BINARY Output ................................................................................................................ 5-2 RS-422A/485 Dedicated Commands and Responses ..................................................... 5-5 5.2 Output Format of ASCII Data ........................................................................................... 5-6 Setting/Basic Setting data ................................................................................................ 5-6 Decimal Point Position/Unit Information........................................................................... 5-7 Measured/computed Data................................................................................................ 5-8 Report Data Generated by the Periodic Printout ........................................................... 5-10 Status Information .......................................................................................................... 5-12 User Information ............................................................................................................ 5-12 5.3 Output Format of BINARY Data ..................................................................................... 5-13 Measured/Computed Data and FIFO Data .................................................................... 5-13 Chapter 6 Status Information 6.1 Status Information and Filter ............................................................................................ 6-1 6.2 The Bit Structure of the Status Information ...................................................................... 6-2 Status Information 1 ......................................................................................................... 6-2 Status Information 2 ......................................................................................................... 6-2 Status Information 3 ......................................................................................................... 6-2 Status Information 4 ......................................................................................................... 6-2 Contents

Appendix 1 ASCII Character Codes ........................................................................................App-1

Appendix 2 Output Flow of FIFO Data ....................................................................................App-2 Appendix 3 Login Procedure ...................................................................................................App-4 Appendix 4 A List of Error Messages ......................................................................................App-6 Setting Errors ...............................................................................................................App-6 Operation Errors ..........................................................................................................App-7 Communication Errors .................................................................................................App-7 Warning Messages ......................................................................................................App-8 System Errors ..............................................................................................................App-8 Index

Overview of the Communication Functions

1.1 Communication Functions Using the Ethernet Interface (/C7 Option) The recorder can be equipped with an optional Ethernet interface. For details on how to use the Ethernet interface, see chapter 2. Functional Construction The following figure shows the relationship between the communication function of the recorder and the Ethernet interface. Perform communication according to the respective protocol. * Protocol is a set of rules that two computers use to communicate via a communication line (or network). PC Connect the recorder and the PC using an Ethernet cable. Maintenance/ Test Server Setting/ Measurement Server Instrument Information Server Login (user authentication/access privileges granting) Upper layer protocol Dedicated protocol Lower layer protocol TCP IP Interface Ethernet (10BASE-T) UDP Communication functions of the recorder Application TCP (Transmission Control Protocol) UDP (User Datagram Protocol) IP (Internet Protocol) Setting/Measurement Server • You can specify settings that are approximately equivalent to those specified by front panel key operations. However, you cannot turn the power ON/OFF, set the user name and password for communications, nor set the key lock. • The data below can be output. Data Type Output Format Measured/computed data BINARY/ASCII Setup data ASCII Periodic printout and the most recent TLOG computation data ASCII Status information ASCII Information on connected users ASCII • The commands that can be used are Setting commands, Basic Setting commands, Control commands, and Output commands. • Ethernet interface settings: Section 2.3 • Commands: Section 4.2 • Data output format: Chapter 5 Chapter 1 Overview of the Communication Functions

Outputs Ethernet communication information such as connection information and

network statistics from the recorder. • The commands that can be used Maintenance/Test commands. • Ethernet interface settings: Section 2.3 • Commands: Section 4.2 Instrument Information Server • Outputs the serial number, model name, and other information about the recorder connected via the Ethernet network. • The commands that can be used Instrument Information Output commands. • Ethernet interface settings: Section 2.3 • Commands: Section 4.2 1.1 Communication Functions Using the Ethernet Interface (/C7 Option)

Overview of the Communication Functions

Other Functions • Login Function Only users that are registered in advance can access the Setting/Measurement and Maintenance/Test servers. • Users are identified by their user name and password. • You can register one administrator and six users. Administrator privileges The administrator can use all the functions on the Setting/Measurement and Maintenance/Test servers User Privileges • Setting/Measurement server Users can output measured data, setup data, scheduled printing, and the most recent TLOG computation data. Users cannot control the recorder. • Maintenance/Test server Users cannot disconnect communications between the recorder and other PCs. All other operations are allowed. • There is a maximum number of simultaneous connections that can be established with the recorder. • Login function settings: Section 2.5 • Maximum number of simultaneous connections: Section 2.1 • Commands available to the administrator and users: Section 4.2 • Communication Timeout This function drops the connection with the PC if there is no data transmission for a given time at the application level (see “Functional Construction”). For example, this function prevents a PC from being connected to the recorder indefinitely which would prohibit other users from making new connections for data transfer. • Communication timeout setting: Section 2.6 • Keepalive This function drops the connection if there is no response to the inspection packet that is periodically transmitted at the TCP level. • Keepalive setting: Section 2.6 1.1 Communication Functions Using the Ethernet Interface (/C7 Option)

Communication Functions Using the RS-422A/

485 Communication Interface (/C3 Option) The recorder can be equipped with an optional RS-422A/485 communication interface. For details on how to use the RS-422A/485 communication interface, see chapter 3. Functional Construction The following figure shows the relationship between the communication function of the recorder and the RS-422A/485 communication interface. Perform communication according to the respective protocol. * Protocol is a set of rules that two computers use to communicate via a communication line (or network). PC Connect the recorder and the PC using a serial cable. Setting/Measurement Server Dedicated protocol Protocol Interface RS-422A/485 Modbus Slave Modbus protocol Communication functions of the recorder Application Setting/Measurement Server The functions are the same as those of the Setting/Measurement server of the Ethernet interface. See page 1-1. • RS-422A/485 communication interface settings: Section 3.5 • Commands: Section 4.2 • RS-422A/485 dedicated commands: Section 4.8 • Data output format: Chapter 5 Modbus Slave • The Modbus protocol can be used to read the measured/computed data on your PC by reading the input registers of the recorder. The communication input data can be written or read by writing/reading the hold register of the recorder. • For details on the Modbus function codes that the recorder supports, see section 3.4. • This function can be used only when communicating via the serial interface (option). • For a description on the settings required in using this function, see section 3.5. Data from slave device Data to slave device Modbus master device Modbus slave device Serial communication Recorder

Using the Ethernet Interface (/C7 Option)

2.1 Ethernet Interface Specifications Basic Specifications Item Specifications Electrical and mechanical specifications Conforms to IEEE 802.3 (Ethernet frames are of DIX specification) Transmission medium type 10BASE-T Protocol TCP, IP, UDP, ICMP, and ARP The Maximum Number of Simultaneous Connections and the Number of Simultaneous Use The following table shows the maximum number of simultaneous connections, the number of simultaneous users, and the port numbers of the recorder. Function Maximum Number Number of Simultaneous Users Port Number† of Connections Setting/Measurement 3 1 2†† 34260/tcp server Maintenance/Test 1 1 1†† 34261/tcp server Instrument - - - 34264/udp Information server † The port numbers are fixed. †† For details on administrator and user privileges, see “Login Function” in section 1.1. Chapter 2 Using the Ethernet Interface (/C7 Option)

Connecting the Ethernet Interface

When Connecting Only the Recorder and a PC Connect the recorder and the PC via a HUB as in the following figure. Hub RD100B/RD1800B Recorder RD100B/RD1800B Recorder PC 10BASE-T straight cable 10BASE-T straight cable When Connecting to a Preexisting Network The following figure illustrates an example in which a recorder and a PC are connected to the network. When connecting the recorder or the PC to a preexisting network, the transfer rate, connector type, etc. must be matched. For details, consult your system or network administrator. Hub, router, etc. Network RD100B/RD1800B Recorder PC 10BASE-T straight cable Note • Depending on the reliability of the network or the volume of network traffic, all the transferred data may not be retrieved by the PC. • Communication performance deteriorates if multiple PCs access the recorder simultaneously.

Using the Ethernet Interface (/C7 Option)

2.3 Configuring the Ethernet Interface Set the host name and IP address of the recorder. You do not have to set the DNS (domain name system). Setup Items DNS Ethernet End Local IP A M G IP address Subnet mask Host name Domain name Default gateway DNS P S DNS On/Off Server (primary) Server (secondary) Host Domain Suffix_P Suffix_S Domain suffix (primary) Domain suffix (secondary) Host Procedure For a description of the basic setup operations, see “Basic Key Operations” on page v. Entering Basic Setting Mode Hold down the MENU key for 3 seconds to display the Setting mode screen. Next, hold down both the ( DISP ) key and the ( FUNC ) key for 3 seconds to display the Basic Setting mode screen. Note To cancel an operation, press the ESC key. Host Name and Domain Name 1. Press the key to select Ethernet and then press the key. Basic=Ethernet 2. Press the key to select Host and then press the key. Ethernet=Host 3. Set the host name of the recorder and then press the key. Key operations • Use the key to select the digit for entering a character. • Use the CHARACTER key to select the character type. • Use the key to select the character you wish to enter. Host= 4. Set the domain name and press the key in the same fashion as in step 3. The setting complete screen appears. Domain= Ethernet host Setting complete 5. Press the ESC key to return to the higher level menu. To save the settings and exit from Basic Setting mode, proceed to “Saving the Settings.” * When the key, key, or key is pressed while holding down the SHIFT key, the operation is reversed as when the respective key is pressed by itself. CHARACTER

IP Address, Subnet Mask, and Default Gateway

1. Press the key to select Ethernet and then press the key. Basic=Ethernet 2. Press the key to select Local IP and then press the key. Ethernet=Local IP 3. Set the IP address of the recorder and then press the key. Key operations • Use the key to select the digit for entering a value. • Use the key to select the value you wish to enter. A= 4. Set the IP address of the subnet mask and then press the key in the same fashion as in step 3. M= 5. Set the IP address of the default gateway and then press the key in the same fashion as in step 3. The local IP setting complete screen appears. G= Ethernet address Setting complete 6. Press the ESC key to return to the higher level menu. To save the settings and exit from Basic Setting mode, proceed to “Saving the Settings.” DNS (Domain Name System) 1. Press the key to select Ethernet and then press the key. Basic=Ethernet 2. Press the key to select DNS and then press the key. Ethernet=DNS 3. Press the key to select On and then press the key. DNS=On 4. Set the IP address of the primary DNS server and then press the key. Key operations • Use the key to select the digit for entering a value. • Use the key to select the value you wish to enter. P= 5. Set the IP address of the secondary DNS server and then press the key in the same fashion as in step 4. S= 2.3 Configuring the Ethernet Interface * When the key, key, or key is pressed while holding down the SHIFT key, the operation is reversed as when the respective key is pressed by itself. CHARACTER

Using the Ethernet Interface (/C7 Option)

6. Set the primary domain suffix and then press the key. Key operations • Use the key to select the digit for entering a character. • Use the CHARACTER key to select the character type. • Use the key to select the character you wish to enter. Suffix_P= 7. Set the secondary domain suffix and then press the key in the same fashion as in step 6. The DNS setting complete screen appears. Suffix_S= Ethernet DNS Setting complete 8. Press the ESC key to return to the higher level menu. To save the settings and exit from Basic Setting mode, proceed to “Saving the Settings.” Saving the Settings 1. Press the ESC key to return to the Basic= screen. 2. Press the key to select End and then press the key. 3. Press the key to select Store and then press the key. The settings are activated, and the Operation mode screen appears. Explanation For details on the settings, consult your system or network administrator. • Host Name Set the recorder’s host name and the domain name of the network to which the recorder belongs. Be sure to set these items when using the DNS. • Host Set the recorder’s host name using up to 64 alphanumeric characters. • Domain Set the network domain name to which the recorder belongs using up to 64 alphanumeric characters. • IP Address, Subnet Mask, and Default Gateway • IP address • Set the IP address to assign to the recorder. The default value is 0.0.0.0. • The IP address is used to distinguish between the various devices connected to the Internet when communicating using the TCP/IP protocol. The address is a 32-bit value normally expressed with four values (0 to 255), each separated by a period as in 192.168.111.24. • M (Subnet Mask) • Specify the mask that is used to determine the network address from the IP address. The default value is 0.0.0.0. • Set this value according to the system or the network to which the recorder belongs. In some cases, this setting may not be necessary. 2.3 Configuring the Ethernet Interface * When the key, key, or key is pressed while holding down the SHIFT key, the operation is reversed as when the respective key is pressed by itself. CHARACTER

• G (Default Gateway)

• Set the IP address of the gateway (router, etc.) used to communicate with other networks. The default value is 0.0.0.0. • Set this value according to the system or the network to which the recorder belongs. In some cases, this setting may not be necessary. • Setting the DNS (Domain Name System) The DNS is a system that correlates the host name/domain name to the IP address. The host name/domain name can be used instead of the IP address when accessing the network. The DNS server manages the database that contains the host name/ domain name and IP address correlation. • On/Off Select On when using the DNS. • P (Primary DNS Server) Set the IP address of the primary DNS server. The default value is 0.0.0.0. • S (Secondary DNS Server) Set the IP address of the secondary DNS server. The default value is 0.0.0.0. If the primary DNS server is down, the secondary server is used to search the host name and IP address correlation. • Suffix_P (Primary Domain Suffix), Suffix_S (Secondary Domain Suffix) When the recorder searches another server using the DNS server, the domain name of the recorder is appended to the host name as a possible domain name if it is omitted. If the IP address corresponding to the server name is not found on the DNS server, then it may be that the system is configured to use another domain name for searching. This alternate domain name is specified as the domain suffix. • Set the domain suffix using up to 64 alphanumeric characters. • Up to two domain suffixes can be specified (primary and secondary). • Saving the Settings To activate the settings made in the Basic Setting mode, the settings must be saved. 2.3 Configuring the Ethernet Interface

Using the Ethernet Interface (/C7 Option)

2.4 Checking the Connection Status The connection status of the Ethernet interface can be confirmed with the indicator that is located to the left of the Ethernet port on the recorder. Indicator Connection Status of the Ethernet Interface ON (Green) The Ethernet interface is electrically connected. Blinking (Green) Transmitting data. OFF The Ethernet interface is not electrically connected. Optional terminal block Ethernet port Indicator

Users that can access the recorder via the Ethernet network must be registered. This

function is called login function. Setup Items LoginSet Ethernet End Level Register User Admin/User On/Off Use/Not User name Login Password Login Procedure For a description of the basic operations, see “Basic Key Operations” on page v. Entering Basic Setting Mode Hold down the MENU key for 3 seconds to display the Setting mode screen. Next, hold down both the ( DISP ) key and the ( FUNC ) key for 3 seconds to display the Basic Setting mode screen. Note To cancel an operation, press the ESC key. Enabling/Disabling the Login Function 1. Press the key to select Ethernet and then press the key. Basic=Ethernet 2. Press the key to select Login and then press the key. Ethernet=Login 3. Press the key to select Use and then press the key. The setting complete screen appears. Login=On 4 Press the ESC key to return to the Ethernet menu. Registering Users 5. Press the key to select LoginSet and then press the key. Ethernet=LoginSet 6. Press the key to select Admin (administrator) or User1 to User6, and then press the key. Level=Admin 7. Press the key to select On and then press the key. Register=On * When the key, key, or key is pressed while holding down the SHIFT key, the operation is reversed as when the respective key is pressed by itself. CHARACTER

Using the Ethernet Interface (/C7 Option)

8. Set the user name and then press the key. Key operations • Use the key to select the digit for entering a character. • Use the CHARACTER key to select the character type. • Use the key to select the character you wish to enter. User= 9. Set the password and then press the key in the same fashion as in step 8. The setting complete screen appears. Password= Ethernet login Setting complete To register other users, press the key to return to step 6 and repeat steps 8, 8, and 9. Saving the Settings 1. Press the ESC key to return to the Basic= screen. 2. Press the key to select End and then press the key. 3. Press the key to select Store and then press the key. The settings are activated, and the Operation mode screen appears. Explanation You can limit the users that can access the Setting/Measurement and Maintenance/Test servers on the recorder via the Ethernet interface. • Enabling/Disabling the Login Function Set whether to use the login function. • Registering Users • User level Select either of the user levels, administrator or user. • Administrator One administrator can be registered. An administrator has the authority to use all Setting/Measurement server and Maintenance/Test server commands. • User Six users can be registered. A user has limited authority to use the commands. See section 4.2. • Selecting Whether to Register (On/Off) the User If On is selected, set the user name and password. • Setting the User Name • Set the user name using up to 16 alphanumeric characters. • The same user name can not be registered. • Since the word “quit” is reserved as a command on the recorder, the user name “quit” is not allowed. • Setting the Password Set the password using up to 4 alphanumeric characters and spaces. 2.5 Registering Users * When the key, key, or key is pressed while holding down the SHIFT key, the operation is reversed as when the respective key is pressed by itself. CHARACTER

• The relationship between the login function and the user name that is used when accessing

the recorder is as follows: • When the login function is set to “Use” • The registered user name and password can be used to login to the recorder. • The user level is the level that was specified when the user name was registered. • When the login function is set to “Not” • The user name “admin” can be used to login to the recorder as an administrator. Password is not necessary. • The user name “user” can be used to access the recorder as a user. Password is not necessary. • There are limitations on the number of simultaneous connections or simultaneous uses of the recorder from the PC (see section 2.1). • For a description of the login process of the Setting/Measurement server and Maintenance/ Test server, see appendix 3. • Saving the Settings To activate the settings made in the Basic Setting mode, the settings must be saved. 2.5 Registering Users

Using the Ethernet Interface (/C7 Option)

2.6 Setting the Communication Timeout and Keepalive The communication timeout function and the keepalive function can be configured. Setup Items K.Alive Ethernet End Keep alive On/Off On/Off Timeout Timeout time Duration Timeout Procedure For a description of the basic operations, see “Basic Key Operations” on page v. Entering Basic Setting Mode Hold down the MENU key for 3 seconds to display the Setting mode screen. Next, hold down both the ( DISP ) key and the ( FUNC ) key for 3 seconds to display the Basic Setting mode screen. Note To cancel an operation, press the ESC key. Communication Timeout 1. Press the key to select Ethernet and then press the key. Basic=Ethernet 2. Press the key to select Timeout and then press the key. Ethernet=Timeout 3. Press the key to select On and then press the key. Timeout=On 4. Set the timeout time and then press the key. Key operations • Use the key to select the digit for entering a value. • Use the key to select the value you wish to enter. Duration= Ethernet timeout Setting complete 5 Press the ESC key to return to the higher level menu. To save the settings and exit from Basic Setting mode, proceed to “Saving the Settings.” * When the key, key, or key is pressed while holding down the SHIFT key, the operation is reversed as when the respective key is pressed by itself. CHARACTER

key to select Ethernet and then press the

key. Basic=Ethernet 2. Press the key to select K.Alive and then press the key. Ethernet=K. Alive 3. Press the key to select On and then press the key. The setting complete screen appears. Keep alive=On Keep alive Setting complete 5 Press the ESC key to return to the higher level menu. To save the settings and exit from Basic Setting mode, proceed to “Saving the Settings.” Saving the Settings 1. Press the ESC key to return to the Basic= screen. 2. Press the key to select End and then press the key. 3. Press the key to select Store and then press the key. The settings are activated, and the Operation mode screen appears. Explanation The communication timeout function and the keepalive function can be configured. • Communication Timeout • Selecting On or Off If On is selected, set the timeout time. • Timeout Time If communication timeout is enabled, the connection is dropped if no data transfer is detected over a time period specified here. Selectable range: 1 to 120 minutes • Enabling (On)/Disabling (Off) Keepalive Select On to enable the keepalive function. • Saving the Settings To activate the settings made in the Basic Setting mode, the settings must be saved. Keepalive: Section 1.1 2.6 Setting the Communication Timeout and Keepalive * When the key, key, or key is pressed while holding down the SHIFT key, the operation is reversed as when the respective key is pressed by itself. CHARACTER

Using the RS-422A/485 Communication Interface (/C3 Option)

3.1 RS-422A/485 Communication Interface Specifications This section describes the RS-422A/485 communication interface specifications. Item Specifications Terminal block type Number of terminals: 6, terminal attachment screws: ISO M4/nominal length of 6 mm Electrical and mechanical Complies with the EIA-422A(RS-422A) and specifications EIA-485(RS-485) standards Connection Multidrop Four-wire system 1:32 Two-wire system 1:31 (Modbus slave protocol) Transmission mode Half-duplex Synchronization Start-stop synchronization Baud rate Select from 1200, 2400, 4800, 9600, 19200, and 38400 [bps]. Start bit Fixed to 1 bit Data length Select 7 or 8 bits Parity Select Odd, Even, or None (no parity). Stop bit Fixed to 1 bit Received buffer length 2047 bytes Escape sequence Open and close Electrical characteristics 6 points consisting of FG, SG, SDB, SDA, RDB, and RDA The SG, SDB, SDA, RDB, and RDA terminals and the internal circuitry of the recorder are functionally isolated. The FG terminal is the frame ground. Communication distance Up to 1.2 km Terminal resistance 120 Ω, 1/2 W Chapter 3 Using the RS-422A/485 Communication Interface (/C3 Option)

Terminal Arrangement and Signal Names and

the Connection Procedure of the RS-422A/485 Communication Interface Terminal Arrangement and Signal Names L N ALARM CHART REMOTE 1 2 3 RS-422A SD SD SG A B G RD RD FG A B G 4 5 C NO C NC NO C NC NO C NC NO C NC NO C NC NO C NC RS-422A SD SD SG A B RD RD FG A B SDA SDB SG RDA RDB FG Rear panel Terminal Name Description FG (Frame Ground) Case ground of the recorder. SG (Signal Ground) Signal ground. SDB (Send Data B) Send data B (+). SDA (Send Data A) Send data A (–). RDB (Received Data B) Receive data B (+). RDA (Received Data A) Receive data A (–). Connection Procedure • Cable Use the cable that meets the conditions below. Item Conditions Cable Shielded twisted pair cable 3 pairs AWG24-14 (Four-wire system), 2 pairs 24 AWG or more (Two-wire system) Characteristic impedance 100 Ω Capacitance 50 pF/m Cable length Up to 1.2 km* * The transmission distance of the RS-422A/485 interface is not the straight-line distance, but rather the total length of the (shielded twisted-pair) cable. • Connecting the Cable As shown in the following figure, attach a crimp-on lug with isolation sleeves for 4 mm screws to the end of the cable. Keep the exposed section from the end of the shield within 5 cm. SDA SDB SG RDA RDB FG Electric potential of the shield Shield Four-wire system Two-wire system SDA SDB SG RDA RDB FG Electric potential of the shield Shield

Using the RS-422A/485 Communication Interface (/C3 Option)

WARNING To prevent the possibility of electric shock, connect the cables with the power turned OFF. Note • Connect the RD pin to the SD (TD) pin on the PC (converter) end and the SD pin to the RD pin on the PC end. • The two-wire system can be used only when using the Modbus protocol. Connection Example with a Host Computer A connection can be made with a host computer having a RS-232, RS-422A, or RS-485 port. • In the case of RS-232, a converter is used. • For recommended converters, see “Serial Interface Converter” on the next page. • The two-wire system can be used only when using the Modbus protocol. For the configuration procedure, see section 3.5 • Four-Wire System Generally, a four-wire system is used to connect to a host computer. In the case of a four-wire system, the transmission and reception lines need to be crossed over. Terminator (external) 120 Ω 1/2W or greater #1 Do not connect terminators to #1 through #n-1. RS-422A/485 terminal on the recorder #2 #n (#n ≤ 32) Terminator (external) Host computer SG RDB( + ) RDA( - ) SDB( + ) SDA( - ) FG SG RD B RD A SD B SD A (SG) (RD B) (RD A) (SDB) (SDA) FG SG RD B RD A SD B SD A (SG) (RD B) (RD A) (SDB) (SDA) FG SG RD B RD A SD B SD A (SG) (RD B) (RD A) (SDB) (SDA) 3.2 Terminal Arrangement and Signal Names and the Connection Procedure of the RS-422A/485 Communication Interface

(The following figure illustrates the case when the host computer’s interface is RS-232.)

Terminator (external) 120 Ω 1/2W or greater #1 Do not connect terminators to #1 through #n-1. RS-422A/485 terminal on the recorder #2 #n (#n ≤ 32) Terminator (external) SHIELD RD( + ) RD( - ) TD( + ) TD( - ) FG SG RD B RD A SD B SD A Host computer Converter (SG) (RD B) (RD A) (SDB) (SDA) FG SG RD B RD A SD B SD A (SG) (RD B) (RD A) (SDB) (SDA) FG SG RD B RD A SD B SD A (SG) (RD B) (RD A) (SDB) (SDA) RS-232 • Two-Wire System Connect the transmission and reception signals with the same polarity on the RS- 422A/485 terminal block. The two-wire system can be used only when using the Modbus protocol. Terminator (externally attached) 120 Ω, 1/2 W or more #1 Do not connect terminator to #1 to #n–1 #2 #n (#n ≤ 31) Terminator (externally attached) Host computer SG RDB( + ) RDA( – ) SDB( + ) SDA( – ) FG SG RD B RD A SD B SD A (SG) (B) (A) (B) (A) FG SG RD B RD A SD B SD A (SG) FG SG RD B RD A SD B SD A (SG) (B) (A) RS-422A/485 terminal on the recorder 3.2 Terminal Arrangement and Signal Names and the Connection Procedure of the RS-422A/485 Communication Interface

Using the RS-422A/485 Communication Interface (/C3 Option)

(The following figure illustrates the case when the host computer’s interface is RS-232.) Terminator (externally attached) 120 Ω, 1/2 W or more #1 Do not connect terminator to #1 to #n–1 #2 #n (#n ≤ 31) Terminator (externally attached) FG SG RD B RD A SD B SD A (SG) (B) (A) (B) (A) FG SG RD B RD A SD B SD A (SG) FG SG RD B RD A SD B SD A (SG) (B) (A) SHIELD TD( + ) TD( – ) RD( + ) RD( – ) Host computer Converter RS-232 RS-422A/485 terminal on the Recorder Note • The method used to eliminate noise varies depending on the situation. In the connection example, the shield of the cable is connected only to the recorder’s ground (one-sided grounding). This is effective when there is a difference in the electric potential between the computer’s ground and the recorder’s ground. This may be the case for long distance communications. If there is no difference in the electric potential between the computer’s ground and the recorder’s ground, the method of connecting the shield also to the computer’s ground may be effective (two-sided grounding). In addition, in some cases, using two-sided grounding with a capacitor connected in series on one side is effective. Consider these possibilities to eliminate noise. • When using the two-wire type interface (Modbus protocol), the 485 driver must be set to high impedance within 3.5 characters after the last data byte is sent by the host computer. • Serial Interface Converter CAUTION Some converters have FG and SG pins that are not isolated. In this case, do not connect anything to the converter’s FG and SG pins (unlike the figure on the previous page). Especially in the case of long distance communications, the potential difference that appears may damage the recorder or cause communication errors. For converters that do not have the SG pin, they can be used without using the signal ground. For details, see the manual that came with the converter. On some non-recommended converters, the signal polarity may be reversed (A/B or +/- indication). In this case, reverse the connection. 3.2 Terminal Arrangement and Signal Names and the Connection Procedure of the RS-422A/485 Communication Interface

For a two-wire system, the host computer must control the transmission driver of the

converter in order to prevent collisions of transmit and received data. When using the recommended converter, the driver is controlled using the RS (RTS) signal on the RS- 232. • When Instruments That Support Only the RS-422A Interface Exist in the System When using the four-wire system, up to 32 recorders can be connected to a single host computer. However, this may not be true if instruments that support only the RS- 422A interface exist in the system. When the instrument that support only the RS-422A interface exist in the system The maximum number of connection is 16. Some of OMEGA’s conventional recorder only support the RS-422A driver. In this case, only up to 16 units can be connected. Note In the RS-422A standard, 10 is the maximum number of connections that are allowed on one port (for a four-wire system). • Terminator When using a multidrop connection (including a point-to-point connection), connect a terminator only to the recorder on the end of the chain. In addition, turn the terminator on the host computer ON (see the computer’s manual). If a converter is being used, turn ON its terminator. The terminator must be attached externally to the recommended converters. 3.2 Terminal Arrangement and Signal Names and the Connection Procedure of the RS-422A/485 Communication Interface

Using the RS-422A/485 Communication Interface (/C3 Option)

3.3 The Bit Structure of One Character and the Operation of the Receive Buffer The Bit Structure of One Character The serial interface on the recorder communicates using start-stop synchronization. In start-stop synchronization, a start bit is added every time a character is transmitted. The start bit is followed by the data bits, parity bit, and stop bit. (See the figure below.) Data bit (7 or 8 bits) 1 character Stop bit Parity bit Even, Odd, or None Start bit Circuit idle state Return to the idle state (dotted line) or the start bit of the next data character (solid line) Receive Buffer and Received Data The data received from the PC is first placed in the receive buffer of the recorder. When the received buffer becomes full, all of the data that overflow are discarded.

Modbus Slave Protocol Specifications

The Modbus slave protocol specifications of the recorder are as follows: Item Specifications Transmission medium RS-422A/485 Flow control None only Baud rate Select from 1200, 2400, 4800, 9600, 19200, or 38400 [bps] Start bit Fixed to 1 bit Stop bit Fixed to 1 bit Parity check Select odd, even, or none (no parity). Transmission mode RTU (Remote Terminal Unit) mode only • Data length: 8 bits • Data interval: 24 bits or less* • Error detection: Uses CRC-16 * Determines message termination with a time interval to 3.5 characters or more. Maximum number of Four-wire system: 32 slave devices connected units Two-wire system: 31 slave devices The function codes of the Modbus slave protocol that the recorder supports are shown below. The recorder does not support broadcast commands. Function Code Specifications Operation 3 Read the hold register (4xxxx). The master device can read the communication input data written using function codes 6 and 16. 4 Read the input register (3xxxx). The master device loads the computed, measured, alarm, and time data of the recordr. 6 Single write to hold register (4xxxx) The master device writes to the communication input data of the recorder. 8 Loopback test The master device performs a loopback test of the recorder. The recorder only supports message return (test code 0x00*) 16 Write to the hold register (4xxxx) The master device writes to the communication input data of the recorder. * Hexadecimal ”00”

Using the RS-422A/485 Communication Interface (/C3 Option)

3.4 Modbus Slave Specifications Registers The registers for using the Modbus slave protocol are listed below. The register data does not contain unit and decimal point position information. Set them on the Modbus master. Binary values are stored to the register in order from the highest byte. Input register Data 30001 Measured data of CH01 : : 30024 Measured data of CH24 • The data is a 16-bit signed integer. The value is the same as the measured data in binary output format (see page 5-13). • The decimal point and unit information varies depending on the range setting of each channel. • Valid channels vary depending on the device. An error response (code 2) occurs when an invalid channel is read. 31001 Alarm status of the measured data of CH01 : : 31024 Alarm status of the measured data of CH24 • The data is a 16-bit signed integer. The value is the same as the alarm status in binary output format (see page 5-13). The data is entered in the "A2A1A4A3" order in the register. • Valid channels vary depending on the device. An error response (code 2) occurs when an invalid channel is read. 32001 Computed data of CH0A (lower word) 32002 Computed data of CH0A (upper word) 32003 Computed data of CH0B (lower word) 32004 Computed data of CH0B (upper word) : : 32048 Computed data of CH1P (upper word) • Registers corresponding to models with the /M1 computation function option. • The data is a 32-bit signed integer. Two registers are assigned for each data point. The value is the same as the computed data in binary output format (see page 5-13). • The decimal point and unit information varies depending on the span setting of each channel. • Valid channels vary depending on the device. An error response (code 2) occurs when an invalid channel is read. 33001 Alarm status of the computed data of CH0A : : 33024 Alarm status of the computed data of CH1P • Registers corresponding to models with the /M1 computation function option. • Data type and value are the same as those of the alarm status of the measured data. • Valid channels vary depending on the device. An error response (code 2) occurs when an invalid channel is read. 36001 List of alarms of the measured data of CH01 to CH04 36002 List of alarms of the measured data of CH05 to CH08 36003 List of alarms of the measured data of CH09 to CH12 36004 List of alarms of the measured data of CH13 to CH16 36005 List of alarms of the measured data of CH17 to CH20 36006 List of alarms of the measured data of CH21 to CH24 1 register (1 word) Level 1 Level 2 Level 3 Level 4 The bit is set to 1 when an alarm occurs. Example of Register 36001 CH4 CH3 CH2 CH1 36007 to 36020 Always 0

List of alarms of the measured data of CH0A to CH0D

36022 List of alarms of the measured data of CH0E to CH0J 36023 List of alarms of the measured data of CH0K to CH0P 36024 List of alarms of the measured data of CH1A to CH1D 36025 List of alarms of the measured data of CH1E to CH1J 36026 List of alarms of the measured data of CH1K to CH1P • The register details are same as the list of alarms of measured data. • Registers 36001 to 35026 can be read with a single command. 39001 Year (4 digits) 39002 Month 39003 Day 39004 Hour 39005 Minute 39006 Second 39007 Millisecond 39008 Summer/Winter time Hold register Data 40001 Communication input data of C01 : : 40024 Communication input data of C24 • Pen model: C01 to C08, dot model: C01 to C12 (RD100B), C01 to C24 (RD1800B) • The data is a 16-bit signed integer. Modbus Error Response The recorder returns the following error codes to the master device. For the error messages related to communications that the recorder displays, see appendix 4. Code Meaning Cause 1 Bad function code Unsupported function request. 2 Bad register number Attempted to read/write to a register that has no corresponding channel. 3 Bad number of registers The specified number of registers is less than or equal to 0 or greater than or equal to 126 (when reading)/124 (when writing). However, no response is returned for the following cases. • CRC error • Errors other than those in the table above. 3.4 Modbus Slave Protocol Specifications

Using the RS-422A/485 Communication Interface (/C3 Option)

3.5 Setting the Serial Interface The serial interface must be configured. Setup Items RS422/485 Address End Baud rate Data length Parity Protocol Procedure For a description of the basic operations, see “Basic Key Operations” on page v. Entering Basic Setting Mode Hold down the MENU key for 3 seconds to display the Setting mode screen. Next, hold down both the ( DISP ) key and the ( FUNC ) key for 3 seconds to display the Basic Setting mode screen. Note To cancel an operation, press the ESC key. 1. Press the key to select RS422/485 and then press the key. Basic=RS422/485 2. Press the key to select the recorder’s address and then press the key. Address=1 3. Press the key to select the Baud rate value and then press the key. Baud rate=38400 4 Press the key to select the Data length value and then press the key. Data length=8 5 Press the key to select the Parity value and then press the key. Parity=Even 6. Press the key to select the NORMAL value and then press the key. The setting complete screen appears. Protocol=NORMAL RS422/485 Setting complete Saving the Settings 1. Press the ESC key to return to the Basic= screen. 2. Press the key to select End and then press the key. 3. Press the key to select Store and then press the key. The settings are activated, and the Operation mode screen appears.

Select the address from the following range.

01 to 32 • Baud rate Select the baud rate from the following: 1200, 2400, 4800, 9600, 19200, or 38400 • Data length Select the data length from below. To output data in BINARY format, be sure to set the data length to 8 bits. 7 or 8 • Parity (Parity check method) Select the parity check from the following: Odd, Even, or None • Protocol Select the protocol when using the Modbus slave protocol. NORMAL: Standard protocol MODBUS: Modbus slave protocol • Saving the Settings To activate the settings made in the Basic Setting mode, the settings must be saved. 3.5 Setting the Serial Interface

The syntax of the setting/basic setting/output commands (see sections 4.4 to 4.7) of the

instrument is given below. ASCII codes (see appendix 1) are used for the character codes. For the Maintenance/Test command syntax, see section 4.9. For the Instrument Information server command syntax, see section 4.10. Command name Parameter ? Terminator Delimiter Sub delimiter SR 02,SKIP;SR 03,VOLT,2V,-1500,1800 Parameter (02 SKIP·····1800) Delimiter (,) Command name (SR) Sub delimiter (;) Command example • Command Name Defined using two alphabet characters. • Parameter • Command parameters. • Set using alphabet characters or numerical values. • Parameters are separated by delimiters (commas). • When the parameter is a numerical value, the valid range varies depending on the command. • Spaces before and after of the parameter are ignored (except for parameters that are specified using an ASCII character string (unit, tag, and message string), when spaces are valid.) • You can omit the parameters that do not need to be changed from their current settings. However, delimiters cannot be omitted. Example SR 01,,2V If multiple parameters are omitted and delimiters occur at the end of the command, those delimiters can be omitted. Example SR 01,VOLT,,, → SR 01,VOLT • The number of digits of the parameters below is fixed. If the number of digits is not correct when entering the command, a syntax error results. • Date YY/MM/DD (8 characters) YY: Year (Enter the lower two digits of the year.) MM: Month DD: Day • Time HH:MM:SS (8 characters) HH: Hour MM: Minute SS: Second • Channel number: 2 characters (Example: 01, 0A) • Relay number: 3 characters (Example: I01) • Communication input data: 3 characters (Example: C02) • Constants used in the computation function (/M1 option): 3 characters (Example: K03) • Remote control (/R1 option) input terminal status: 3 characters (Example: D04) Chapter 4 Commands

A question mark is used to specify a query.

• By placing a query after a command or parameter, the setting information of the corresponding command can be queried. Some commands cannot execute queries. For the query syntax of each command, see sections 4.4 to 4.7. Example 1 SR[ p1]? SR? or SR p1? can be executed. Example 2 SA[ p1[,p2]]? SA?, SA p1?, or SA p1,p2? can be executed. • Delimiter • A comma is used as a delimiter. • Parameters are separated by delimiters. • Sub Delimiter • A semicolon is used as a sub delimiter. • By separating each command with a sub delimiter, up to 10 commands can be specified one after another. However, the following commands and queries cannot be specified one after another. Use them independently. • Output commands other than BO, CS, and IF commands. • YE command • Queries * If there are consecutive sub delimiters, they are considered to be single. In addition, sub delimiters at the front and at the end are ignored. Example ;SR01,VOLT;;;SR02,VOLT; is taken to be SR01,VOLT;SR02,VOLT. • Terminator (Terminating Character) Use either of the following two characters for the terminator. • CR + LF (0DH 0AH in ASCII code.) • LF (0AH in ASCII code.) Note • The total data length from the first character to the terminator must be less than 2047 bytes. In addition, the character string length of 1 command must be less than 512 bytes. • Commands are not case sensitive (with the exception of user-specified character strings). • All the commands that are listed using sub delimiters are executed even if one of the commands is erroneous. • Spaces that are inserted before and after a parameter are ignored. However, if spaces are inserted before a command, after a sub delimiter, or after a query, an error occurs. Response The recorder returns a response (affirmative/negative response) to a command that is separated by a single terminator.* The controller should follow the one command to one response format. When the command-response rule is not followed, the operation is not guaranteed. For the response syntax, see section 5.1. * The exceptions are the RS-422A/485 dedicated commands (see section 4.8). Note When using the RS-422A/485 interface, allow at least 1 ms before sending the next command after receiving a response. Otherwise, the command may not be processed correctly. 4.1 Command Syntax

A List of Commands

Execution Modes and User Levels Execution Modes The recorder has two execution modes. Each command is specified to be used in a particular execution mode. If you attempt to execute a command in a mode that is different from the specification, a syntax error occurs. Use the DS command to switch to the appropriate mode, and then execute the command. Query commands can be executed in either mode. • Basic Setting mode Measurement/computation is stopped and settings are changed in this mode. • Run mode Run mode collectively refers to Operation mode and Setting mode of the recorder. User Levels The administrator and user specifications in the table indicate the user level that is specified using the login function for Ethernet communications. For details, see section 1.1. Setting Commands Command Function Execution Mode Administrator User Page Name SR Sets the input range. Run mode Yes No 4-10 SO Sets the computing equation (/M1 option). Run mode Yes No 4-11 VB Sets the bias. Run mode Yes No 4-11 SA Sets the alarm. Run mode Yes No 4-11 SN Sets the unit. Run mode Yes No 4-12 SC Sets the chart speed. Run mode Yes No 4-12 SD Sets the date and time. Run mode Yes No 4-13 VT Sets the dot printing interval (dot model). Run mode Yes No 4-13 SZ Sets zone recording. Run mode Yes No 4-13 SP Sets the partial expanded recording. Run mode Yes No 4-13 VR Turns ON/OFF the recording on each channel. Run mode Yes No 4-13 ST Sets the tag. Run mode Yes No 4-14 SG Sets the message. Run mode Yes No 4-14 SE Sets the secondary chart speed Run mode Yes No 4-14 (used by the remote control function (/R1 option)). SV Sets the moving average (dot model). Run mode Yes No 4-14 SF Sets the input filter (pen model). Run mode Yes No 4-14 BD Sets the alarm delay time. Run mode Yes No 4-14 VF Sets the brightness of the display (VFD) and internal Run mode Yes No 4-14 illumination. TD Sets the DST. Run mode Yes No 4-14 SS Sets the DST. (Can be used on the RD100B with system Run mode Yes No 4-15 version 1.02 or earlier) SK Sets the computation constant (/M1 option). Run mode Yes No 4-15 SJ Sets the timer used in TLOG computation (/M1 option). Run mode Yes No 4-15 CM Sets the communication input data (/M1 option). Run mode Yes No 4-15 FR Sets the acquiring interval to the FIFO buffer. Run mode Yes No 4-15 VD Sets the data display screen. Run mode Yes No 4-16 Yes: Command usable No: Command not usable

Basic Setting Commands

Note • In order to activate the settings that are changed using the basic setting commands, the settings must be saved using the YE or XE command. • The settings that are returned in response to a query in the basic setting mode will contain the new settings even if they are not saved. • When the settings are saved with the XE command, communication is not dropped. The settings that are changed using the YS/YB/YA/YN/YD/YQ/YK command are activated after power-cycling the recorder. • When the YE command is executed, communication is dropped. The response to the YE command is not returned. Command Function Execution Mode Administrator User Page Name XA Sets alarm related settings. Basic Setting mode Yes No 4-18 XI Sets the A/D integral time. Basic Setting mode Yes No 4-18 XB Sets the burnout detection. Basic Setting mode Yes No 4-19 XJ Sets the RJC. Basic Setting mode Yes No 4-19 UC Changes the dot color (dot model). Basic Setting mode Yes No 4-19 UO Sets the pen offset compensation (pen model). Basic Setting mode Yes No 4-19 UP Sets the items to be printed. Basic Setting mode Yes No 4-19 UR Sets the periodic printout interval. Basic Setting mode Yes No 4-19 UM Sets the types of report data that are output to the Basic Setting mode Yes No 4-20 periodic printout. UB Sets the display mode of the bar graph. Basic Setting mode Yes No 4-20 UI Sets whether to use moving average (dot model). Basic Setting mode Yes No 4-20 UJ Sets whether to use the input filter (pen model). Basic Setting mode Yes No 4-20 UK Sets whether to use of partial expanded recording. Basic Setting mode Yes No 4-20 UL Selects the display/record language. Basic Setting mode Yes No 4-20 XN Selects the date format. Basic Setting mode Yes No 4-20 XT Selects the temperature unit. Basic Setting mode Yes No 4-21 UF Sets whether to use the extended functions. Basic Setting mode Yes No 4-21 UT Selects the time printout format. Basic Setting mode Yes No 4-21 XR Sets the remote control input (/R1 option). Basic Setting mode Yes No 4-21 YS Sets the RS-422A/485 interface (/C3 option). Basic Setting mode Yes No 4-21 XQ Sets the TLOG timer (/M1 option). Basic Setting mode Yes No 4-22 UN Changes the assignment of channels to the recording pen Basic Setting mode Yes No 4-22 (pen model, /M1 option). US Sets the computation error procedure (/M1 option). Basic Setting mode Yes No 4-22 YB Sets the host name and domain name (/C7 option). Basic Setting mode Yes No 4-22 YA Sets the IP address (/C7 option). Basic Setting mode Yes No 4-22 YN Sets the DNS (/C7 option). Basic Setting mode Yes No 4-23 YD Sets whether to use the login function via communication Basic Setting mode Yes No 4-23 (/C7 option). YQ Sets the communication timeout (/C7 option) Basic Setting mode Yes No 4-23 YK Sets keepalive (/C7 option). Basic Setting mode Yes No 4-23 UA Sets the record position. Basic Setting mode Yes No 4-23 YE Exits from Basic Setting mode. Basic Setting mode Yes No 4-24 XE Exits from Basic Setting mode. Basic Setting mode Yes No 4-24 Yes: Command usable No: Command not usable 4.2 A List of Commands

Switches the execution mode.

All modes Yes No 4-25 RCD PS Starts/Stops recording. Run mode Yes No 4-25 DISP UD Switches the screen/switches the channel. Run mode Yes No 4-25 FUNC AK Executes alarm acknowledge (AlarmACK) Run mode Yes No 4-25 FUNC TL Starts/stops/resets computation (/M1 option). Run mode Yes No 4-25 FUNC MP Starts/Stops manual print. Run mode Yes No 4-25 FUNC LS Starts/Stops the list (setting information) printout. Run mode Yes No 4-25 FUNC SU Starts/Stops the setup list (basic setting information) Run mode Yes No 4-25 printout. FUNC MS Executes the message printout. Run mode Yes No 4-25 FUNC AC Clears the alarm printout buffer. Run mode Yes No 4-25 FUNC MC Clears the message printout buffer. Run mode Yes No 4-26 FUNC VG Resets the report data of the periodic printout. Run mode Yes No 4-26 - YC Initializes the settings. Basic Setting mode Yes No 4-26 - UY Stops the record position adjustment. Basic Setting mode Yes No 4-26 Yes: Command usable No: Command not usable Output Commands Command Command Function Execution Mode Administrator User Page Type Name Control BO Sets the byte output order. All modes Yes Yes 4-26 CS Sets the check sum All modes Yes Yes 4-26 (usable only during serial communications). IF Sets the status filter All modes Yes Yes 4-26 CC Disconnects an Ethernet connection All modes Yes Yes 4-26 (usable only during Ethernet communications) Setup, measurement, and computation data output FE Outputs decimal point position, unit information, All modes Yes Yes 4-27 and setup data. FD Outputs the most recent measured/computed data. Run mode Yes Yes 4-27 FY Outputs the statistical computation results. Run mode Yes Yes 4-27 FF Outputs FIFO data. Run mode Yes Yes 4-27 IS Outputs status information. All modes Yes Yes 4-28 FU Outputs user information. All modes Yes Yes 4-28 Yes: Command usable No: Command not usable RS-422A/485 Dedicated Commands Command Function Execution Mode Administrator User Page Name Esc O Opens the instrument. All modes Yes Yes 4-28 Esc C Closes the instrument. All modes Yes Yes 4-28 Yes: Command usable No: Command not usable 4.2 A List of Commands

These commands can be used only when using Ethernet communications.

Command Name Function Execution Mode Administrator User Page close Disconnects the connection between other instruments. All modes Yes No 4-29 con Outputs connection information. All modes Yes Yes 4-29 eth Output Ethernets statistical information. All modes Yes Yes 4-29 help Outputs help. All modes Yes Yes 4-29 net Outputs network statistical information. All modes Yes Yes 4-29 quit Disconnects the connection of the instrument being All modes Yes Yes 4-30 operated. Yes: Command usable No: Command not usable Instrument Information Output Commands These commands can be used only when using Ethernet communications. Parameter Function Page serial Outputs the serial number. 4-30 host Outputs the host name. 4-30 ip Outputs the IP address. 4-30 4.2 A List of Commands

This section explains frequently used parameters.

Input Range The following tables show the input types (VOLT, TC, RTD, DI, and 1-5V), range types, and the ranges for the leftmost and rightmost values of the span. • DC Voltage (VOLT), Square Root (SQRT), Difference between Channels (DELTA) Range Type Parameter for Range of Leftmost and Range of Leftmost and the SR Command Rightmost Values of Span Rightmost Values of Span of the SR Command 20 mV 20 mV –20.00 to 20.00 mV –2000 to 2000 60 mV 60 mV –60.00 to 60.00 mV –6000 to 6000 200 mV 200 mV –200.0 to 200.0 mV –2000 to 2000 2 V 2 V –2.000 to 2.000 V –2000 to 2000 6 V 6 V –6.000 to 6.000 V –6000 to 6000 20 V 20 V –20.00 to 20.00 V –2000 to 2000 50 V 50 V –50.00 to 50.00 V –5000 to 5000 • 1-5V Range Type Parameter for Range of Leftmost and Range of Leftmost and the SR Command Rightmost Values of Span Rightmost Values of Span of the SR Command 1-5V 1-5V Leftmost value: 800 to 1200 0.8000 to 1.200 V Rightmost value: 4800 to 5200 4.8000 to 5.200 V • Thermocouple (TC) Range Type Parameter for Range of Leftmost and Range of Leftmost and the SR Command Rightmost Values of Span Rightmost Values of Span of the SR Command R R 0.0 to 1760.0°C 0 to 17600 S S 0.0 to 1760.0°C 0 to 17600 B B 0.0 to 1820.0°C 0 to 18200 K K –200.0 to 1370.0°C –2000 to 13700 E E –200.0 to 800.0°C –2000 to 8000 J J –200.0 to 1100.0°C –2000 to 11000 T T –200.0 to 400.0°C –2000 to 4000 N N 0.0 to 1300.0°C 0 to 13000 W W 0.0 to 2315.0°C 0 to 23150 L L –200.0 to 900.0°C –2000 to 9000 U U –200.0 to 400.0°C –2000 to 4000 WRe WRe 0.0 to 2400.0°C 0 to 24000 Difference between channels (DELTA) R - –1760.0 to 1760.0°C –17600 to 17600 S - –1760.0 to 1760.0°C –17600 to 17600 B - –1820.0 to 1820.0°C –18200 to 18200 K - –1570.0 to 1570.0°C –15700 to 15700 E - –1000.0 to 1000.0°C –10000 to 10000 J - –1300.0 to 1300.0°C –13000 to 13000 T - –600.0 to 600.0°C –6000 to 6000 N - –1300.0 to 1300.0°C –13000 to 13000 W - –1999.9 to 2315.0°C –19999 to 23150 L - –1100.0 to 1100.0°C –11000 to 11000 U - –600.0 to 600.0°C –6000 to 6000 WRe - –1999.9 to 2400.0°C –19999 to 24000

• Resistance Temperature Detector (RTD)

Range Type Parameter for Range of Leftmost and Range of Leftmost and the SR Command Rightmost Values of Span Rightmost Values of Span of the SR Command Pt100 PT –200.0 to 600.0°C –2000 to 6000 JPt100 JPT –200.0 to 550.0°C –2000 to 5500 Difference between channels (DELTA) Pt100 - –800.0 to 800.0°C –8000 to 8000 JPt100 - –750.0 to 750.0°C –7500 to 7500 • ON/OFF input (DI) Range Type Parameter for Range of Leftmost and Range of Leftmost and the SR Command Rightmost Values of Span Rightmost Values of Span of the SR Command Level LEVEL 0 to 1† 0 to 1 Contact CONT 0 to 1†† 0 to 1 † “0” when less than 2.4 V, “1” when greater than or equal to 2.4 V. †† “0” when contact is OFF, “1” when contact is ON. Miscellaneous Channel Number • Pen model Measurement channel: 01 to 04 Computation channel: 0A, 0B, 0C, 0D, 0E, 0F, 0G, 0J • Dot model Measurement channel: RD100B: 01 to 06 RD1800B: 01 to 24 Computation channel: RD100B: 0A, 0B, 0C, 0D, 0E, 0F, 0G, 0J, 0K, 0M, 0N, 0P RD1800B: 0A, 0B, 0C, 0D, 0E, 0F, 0G, 0J, 0K, 0M, 0N, 0P, 1A, 1B, 1C, 1D, 1E, 1F, 1G, 1J, 1K, 1M, 1N, 1P Relay Number (/A1, /A2, /A3, /A4, and /A5 Options) • Models with the /A1 option: I01, I02 • Models with the /A2 option: I01 to I04 • Models with the /A3 option: I01 to I06 • Models with the /A4 option: I01 to I06, I11 to I16 (RD1800B) • Models with the /A5 option: I01 to I06, I11 to I16, I21 to I26, I31 to I36 (RD1800B) Communication Input Data RD100B Pen model: C01 to C08, dot model: C01 to C12 µR20000 Pen model: C01 to C08, dot model: C01 to C24 Computation Constant (/M1 option). K01 to K30 Remote Control Input Terminal (/R1 Option) D01 to D05 4.3 Parameter Values

Chart Speed on the Pen Model

5 6 8 9 10 12 15 16 18 20 24 25 30 32 36 40 45 48 50 54 60 64 72 75 80 90 96 100 120 125 135 150 160 180 200 225 240 250 270 300 320 360 375 400 450 480 500 540 600 675 720 750 800 900 960 1000 1080 1200 1350 1440 1500 1600 1800 2000 2160 2250 2400 2700 2880 3000 3600 4000 4320 4500 4800 5400 6000 7200 8000 9000 10800 12000 mm/h 4.3 Parameter Values

4.4 Setting Commands

4.4 Setting Commands SR Sets the input range. When setting channels to skip Syntax SR p1,p2 p1 Channel number p2 Measurement mode (SKIP) Query SR[ p1]? Example Set channel 01 to skip. SR 01,SKIP Description • This command cannot be specified while computation is in progress. • Measurements are not made on channels that are set to SKIP. When setting channels to voltage, TC, RTD, or ON/ OFF input Syntax SR p1,p2,p3,p4,p5 p1 Channel number p2 Measurement mode (Input type) VOLT DC voltage TC Thermocouple RTD Resistance temperature detector DI ON/OFF input p3 Range type p4 Leftmost value of span p5 Rightmost value of span Query SR[ p1]? Example Measure 0°C to 1760.0°C on channel 01 using thermocouple type R. SR 01,TC,R,0,17600 Description • This command cannot be specified while computation is in progress. • Set p3 according to the table in section 4.3. • For p4 and p5, enter an integer value of 5 digits or less according to the table in section 4.3. The decimal position is fixed to the position indicated in the table in section 4.3. When setting channels to 1-5V range Syntax SR p1,p2,p3,p4,p5,p6,p7,p8 p1 Channel number p2 Measurement mode (Input type) (1-5V) p3 Leftmost value of span p4 Rightmost value of span p5 Leftmost value of scaling (−20000 to 30000) p6 Rightmost value of scaling (−20000 to 30000) p7 Scale decimal point position (0 to 4) p8 Whether to use 1-5V low-cut function (ON, OFF) Query SR[ p1]? Example Set channel 01 to 1-5V range and scale the input value in the range 0.0 to 1200.0. Do not use the low-cut function. SR 01,1-5V,1000,5000,0,12000,1,OFF Description • This command cannot be specified while computation is in progress. • For p3 and p4, enter an integer value of 5 digits or less according to the table in section 4.3. The decimal position is fixed to the position indicated in the table in section 4.3. • Be sure that p6 is greater than p5. • Parameter p8 is valid only when the low-cut function is enabled (see the UF command). When computing the difference between channels Syntax SR p1,p2,p3,p4,p5 p1 Channel number p2 Measurement mode (DELTA) p3 Reference channel p4 Leftmost value of span p5 Rightmost value of span Query SR[ p1]? Example Set channel 03 to channel difference computation with respect to channel 01 (reference channel). Set the leftmost and rightmost values of span to −200.0 and 200.0, respectively. SR 03,DELTA,01,−2000,2000 Description • This command cannot be specified while computation is in progress. • The reference channel must be a channel that is smaller in channel number than itself. • The range type is the same as that of the reference channel. • For p4 and p5, enter an integer value of 5 digits or less according to the table in section 4.3. The decimal position is fixed to the position indicated in the table in section 4.3. When setting the linear scaling Syntax SR p1,p2,p3,p4,p5,p6,p7,p8,p9 p1 Channel number p2 Measurement mode (SCALE) p3 Input type VOLT DC voltage TC Thermocouple RTD Resistance temperature detector DI ON/OFF input p4 Range type p5 Leftmost value of span p6 Rightmost value of span p7 Leftmost value of scaling (−20000 to 30000) p8 Rightmost value of scaling (−20000 to 30000) p9 Scaling decimal point position (0 to 4) Query SR[ p1]? Example Scale channel 02 whose input range is 0 to 10 V to −100.0 to 500.0. SR 02,SCALE,VOLT,20V,0,1000,−1000, 5000,1

This command cannot be specified while

computation is in progress. • Set p4 according to the table in section 4.3. • For p5 and p6, enter an integer value of 5 digits or less according to the table in section 4.3. The decimal position is fixed to the position indicated in the table in section 4.3. • Be sure that p8 is greater than p7. When setting the square root Syntax SR p1,p2,p3,p4,p5,p6,p7,p8,p9,p10 p1 Channel number p2 Measurement mode (SQRT) p3 Range type p4 Leftmost value of span p5 Rightmost value of span p6 Leftmost value of scaling (−20000 to 30000) p7 Rightmost value of scaling (−20000 to 30000) p8 Scaling decimal point position (0 to 4) p9 Low-cut function (ON, OFF) p10 Low-cut value Query SR[ p1]? Example Given channel 01 whose input range is 0 to 10 V, take the square root of the input value and scale the result in the range 0.00 (m3/s) to 100.00 (m3/ s). When the input value is less than or equal to 5.0% of the recording span, use the low-cut function. SR 01,SQRT,20V,0,1000,0,10000,2,ON, 50 Description • This command cannot be specified while computation is in progress. • Set p3 according to the table in section 4.3. • For p4 and p5, enter an integer value of 5 digits or less according to the table in section 4.3. The decimal position is fixed to the position indicated in the table in section 4.3. • Be sure that p7 is greater than p6. • Parameters p9 and p10 is valid only when the low-cut function is enabled (see the UF command). SO Sets the computing equation (/M1 option). Syntax SO p1,p2,p3,p4,p5,p6 p1 Computation channel number p2 Turn ON/OFF the computing equation (ON, OFF) p3 Computing equation (up to 120 characters) p4 Leftmost value of span (−9999999 to 99999999) p5 Rightmost value of span (−9999999 to 99999999) p6 Span decimal point position (0 to 4) Query SO[ p1]? Example Calculate the sum of channel 01 and 02 on computation channel 0A. Set the leftmost and rightmost values of span to –10.00 and 15.00, respectively. SO 0A,ON,01+02,−1000,1500,2 Description • This command cannot be specified while computation is in progress. • For a description on the computing equations, see the RD100B Recorder User’s Manual. • For p4 and p5, enter a value using 7 digits or less ,excluding the decimal, for negative numbers and 8 digits or less for positive numbers. VB Sets the bias. Syntax VB p1,p2,p3 p1 Channel number p2 Bias ON/OFF (ON, OFF) p3 Bias value Query VB[ p1]? Example Given channel 03 whose range type is 2V (measurable range: −2.000 to 2.000 V), add a bias of 0.1 V. VB 03,ON,100 Description • Set p3 in the range of ±10% of the span of the measurable range at the range type or ±10% of the scaling span. Specify the value with an integer (see section 4.3). • The bias setting is valid only when the bias function is enabled (see the UF command). SA Sets the alarm. When not using the alarm Syntax SA p1,p2,p3 p1 Channel number p2 Alarm number (1 to 4) p3 Alarm ON/OFF state (OFF) Query SA[ p1[,p2]]? Example Do not use alarm number 4 of channel 01. SA 01,4,OFF When using the alarm Syntax SA p1,p2,p3,p4,p5,p6,p7 p1 Channel number p2 Alarm number (1 to 4) p3 Alarm ON/OFF state (ON) p4 Alarm type H High limit alarm L Low limit alarm h Difference high limit alarm l Difference low limit alarm R High limit on rate-of-change alarm r Low limit on rate-of-change alarm T Delay high limit alarm t Delay low limit alarm (Characters are case-sensitive.) p5 Alarm value 4.4 Setting Commands

4.4 Setting Commands

p6 Relay output ON Relay ON OFF Relay OFF p7 Relay number (RD100B: I01 to I06, RD1800B: I01 to I06, I11 to I16, I21 to I26, I31 to I36) Query SA[ p1[,p2]]? Example Set a high limit alarm (alarm value = 1000) on alarm number 1 of channel 02 and output to relay I01. SA 02,1,ON,H,1000,ON,I01 Description • When the input range is set to SKIP (SR command), p3 cannot be turned ON. • The alarm settings are all turned OFF for the following cases. • When the input type is changed (VOLT, TC, etc). • When the range type is changed. • When the span and scaling values are changed during linear scaling (includes changing the decimal position). • The h and l settings of p4 are valid only when the measurement range is set to computation between channels. • The hysteresis of alarm ON/OFF (valid when p4 is H or L) is set using the XA command. • If p4 is set to R or r, set the interval for the high/low limit on the rate-of-change using the XA command. • The T and t settings of p4 can be specified when the alarm delay function is enabled (UF command). • If p4 is set to T or t, set the alarm delay time for the delay high/low limit alarm using the BD command. • Parameter p5 for the high limit alarm/low limit alarm and delay high limit alarm/delay lowlimit alarm • For DC voltage, TC, and RTD input: Values within the measurable range in the specified range (example: –2.000 to 2.000 V for the 2 V range). • For ON/OFF input (DI): 0 or 1. • For scaling (1-5V, scaling, and square root): −5 to 105% of the scale span (except within −20000 to 30000). • Parameter p5 for the difference high limit alarm/difference low limit alarm: Values in the measurable range can be specified (example: –1760.0 to 1760.0°C for the TC type R). • Parameter p5 for the high limit on rate-of- change alarm/low limit on rate-of-change alarm: A value greater than or equal to 1 digit can be specified. For example, 1 digit corresponds 0.001 for the 2 V range (measurable range: –2.000 to 2.000 V). The maximum value that can be specified is the width of the measurable range (4.000 V for 2 V range). For ON/OFF input, only “1” can be specified. • On models with the computation function (/M1 option), alarms can be set on computation channels. • When the computation equation setting (SO command) is turned OFF, p3 cannot be turned ON. • For computation channels, the alarm types that can be specified are H (high limit alarm), L (low limit alarm), T (delay high limit alarm), and t (delay low limit alarm). T and t can be specified when the alarm delay function is enabled (UF command). • If p4 is set to T or t, set the alarm delay time for the delay high/low limit alarm using the BD command. • Set p5 within the range –9999999 to 99999999 excluding the decimal using an integer. • The alarm ON/OFF hysteresis is set using the XA command. • If the computation channel ON/OFF state, the computing equation, or the span value is changed, all alarm settings of that channel are turned OFF. SN Sets the unit. Syntax SN p1,p2 p1 Channel number p2 Unit string (up to 6 characters) Query SN[ p1]? Example Set the unit of channel 02 to M/H. SN 02,M/H Description • The unit setting is valid on channels set to 1- 5V, scaling, or square root. • For the characters that can be used for the units, see appendix 1, “ASCII Character Codes.” • On models with the computation function (/M1 option), unit can be set on computation channels. SC Sets the chart speed. Syntax SC p1 p1 Chart speed Query SC? Example Set the chart speed to 25 mm/h. SC 25 Description Select the chart speed from the list of choices below. Pen model 5 to 12000 mm/h (82 levels, see section 4.3) Dot model 1 to 1500 mm/h (1 mm steps)

Sets the date and time.

Syntax SD p1 p1 Date and time (fixed to the YY/MM/DD HH:MM:SS format) YY Year (00 to 99, the lower 2 digits) MM Month (01 to 12) DD Day (01 to 31) HH Hour (00 to 23) MM Minute (00 to 59) SS Second (00 to 59) Query SD? Example Set the recorder clock to 13:00:00, December 1, 2004. SD 04/12/01 13:00:00 Description • The format of p1 is fixed to 17 characters. An error results if a space is inserted in positions other than the specified positions. • On the RD100B with system version 1.02 or earlier, the parameter p2 can be used. p2 Standard time or DST (winder, summer) Winter Standard time Summer DST VT Sets the dot printing interval (dot model). Syntax VT p1 p1 Dot printing interval setting. AUTO Automatically adjust the dot printing interval according to the chart speed. FIX Record at the fastest printing interval. Query VT? Example Record at the fastest printing interval. VT FIX Description When trend recording is performed on 6 channels, the fastest printing interval is 10 seconds. SZ Sets zone recording. Syntax SZ p1,p2,p3 p1 Channel number p2 Leftmost position of the zone (RD100B: 0 to 95, RD1800B: 0 to 175) [mm] p3 Rightmost position of the zone (RD100B: 5 to 100, RD1800B: 0 to 180) [mm] Query SZ[ p1]? Example Display channel 02 in a zone between 30 and 50 mm. SZ 02,30,50 Description • Be sure that p3 is greater than p2 and that the zone width (p3 – p2) is greater than or equal to 5 mm. • On models with the computation function (/M1 option), computation channels can be specified. SP Sets the partial expanded recording. Syntax SP p1,p2,p3,p4 p1 Channel number p2 Partial expanded recording ON/OFF (ON, OFF) p3 Boundary position (1 to 99) [%] p4 Boundary value Query SP[ p1]? Example Set the 25% position of channel 01 to 1.000 V. SP 01,ON,25,1000 Description • When the input range is set to SKIP (SR command), p2 cannot be turned ON. • Set p3 as a percentage where 100 mm is assumed to be 100%. • Parameter p4 can be set in the range (leftmost value of span + 1) to (rightmost value of span – 1). If scaling is enabled, the range is (leftmost value of scaling – 1) to (rightmost value of scaling + 1). Set the parameter using an integer. • This setting is possible when partial expanded recording is enabled (UK command). • This command cannot be used if the partial expanded recording range does not exist (when the span width is set to 1, for example). • On models with the computation function (/M1 option), computation channels can be specified. • When the computation equation setting (SO command) is turned OFF, p2 cannot be turned ON. VR Turns ON/OFF the recording on each channel. Dot model Syntax VR p1,p2,p3 p1 Channel number p2 Trend recording ON/OFF (ON, OFF) p3 Periodic printout ON/OFF (ON, OFF) Query VR[ p1]? Example Turn trend recording ON and turn periodic printout OFF on channel 06. VR 06,ON,OFF Description On models with the computation function (/M1 option), computation channels can be specified. Pen model Syntax VR p1,p2 p1 Channel number p2 Periodic printout ON/OFF (ON, OFF) Query VR[ p1]? Example Turn periodic printing ON on channel 01. VR 01,ON Description On models with the computation function (/M1 option), computation channels can be specified. 4.4 Setting Commands

4.4 Setting Commands

ST Sets the tag. Syntax ST p1,p2 p1 Channel number p2 Tag string (up to 7 characters) Query ST[ p1]? Example Set the tag of channel 02 to TI-2. ST 02,TI-2 Description • For the characters that can be used for the tags, see appendix 1, “ASCII Character Codes.” • On models with the computation function (/M1 option), computation channels can be specified. SG Sets the message. Syntax SG p1,p2 p1 Message number (1 to 5) p2 Message string (up to 16 characters) Query SG[ p1]? Example Set character string “START” in message number 1. SG 1,START Description For the characters that can be used for the messages, see appendix 1, “ASCII Character Codes.” SE Sets the secondary chart speed (used by the remote control function (/R1 option)). Syntax SE p1 p1 Secondary chart speed See the explanation. Query SE? Example Set the chart speed to 50 mm/h. SE 50 Description Select the chart speed from the list of choices below. Pen model 5 to 12000 mm/h (82 levels, see section 4.3) Dot model 1 to 1500 mm/h (1 mm steps) SV Sets the moving average (dot model). Syntax SV p1,p2 p1 Channel number p2 Number of samples for computing the moving average (OFF, 2 to 16) [times] Query SV[ p1]? Example Set the number of samples for computing the moving average of channel 02 to 12. SV 02,12 Description • This setting is available on the dot model. • This setting is possible when moving average is enabled (UI command). SF Sets the input filter (pen model). Syntax SF p1,p2 p1 Channel number p2 Filter time constant (OFF, 2s, 5s, 10s) Query SF[ p1]? Example Set the filter of channel 02 to 2 s. SF 02,2s Description This setting is possible when the input filter is enabled (UJ command). BD Sets the alarm delay time. Syntax BD p1,p2 p1 Channel number p2 Alarm delay (1 to 3600) [s] Query BD[ p1]? Example Set the alarm delay of channel 01 to 120 s. BD 01,120 Description • This setting is possible when the alarm delay function is enabled (UF command). • On models with the computation function (/M1 option), computation channels can be specified. VF Sets the brightness of the display (VFD) and internal illumination. Syntax VF p1,p2 p1 VFD brightness (1 to 8) p2 Internal illumination (OFF, 1 to 4) OFF Turns OFF the internal illumination. Query VF? Example Set the display (VFD) brightness to 2 and the internal illumination to 1. VF 2,1 Description The brightness increases as the value increases. TD Sets the DST. Syntax TD p1,p2,p3,p4,p5,p6,p7,p8,p9 p1 Use/Not use DST (USE, NOT) p2 DST start time: month (Jan, Feb, Mar, Apr, May, Jun, Jul, Aug, Sep, Oct, Nov, or Dec) p3 DST start time: number of the week in the month (1st, 2nd, 3rd, 4th, or Last) p4 DST start time: day of the week (Sun, Mon, Tue, Wed, Thu, Fri, or Sat) p5 DST start time: hour (0 to 23) p6 DST end time: month (Jan, Feb, Mar, Apr, May, Jun, Jul, Aug, Sep, Oct, Nov, or Dec) p7 DST end time: number of the week in the month (1st, 2nd, 3rd, 4th, or Last) p8 DST end time: day of the week (Sun, Mon, Tue, Wed, Thu, Fri, or Sat) p9 DST end time: hour (0 to 23) Query TD[ p1]?

Enable DST and set the DST start time to hour 0

on the 2nd Sunday of June and the DST end time to hour 0 on the 2nd Sunday of December. TD Use,Jun,2nd,Sun,0,Dec,2nd,Sun,0 Description • The DST start time and end time cannot be set to the same time. • The TD command can be used on the RD100B and RD1800B with system version 1.11 or later. On the RD100B with system version 1.02 or earlier, use the SS command. SS Sets the DST. Syntax SS p1,p2,p3 p1 Standard time/DST selection Winter Standard time Summer DST p2 Switch time setting ON/OFF (ON, OFF) p3 Date and time (fixed to the YY/MM/DD HH format) YY Year (00 to 99, the lower 2 digits) MM Month (01 to 12) DD Day (01 to 31) HH Hour (00 to 23) Query SS[ p1]? Example Switch to DST on 0 hour of June 1st, 2005. SS Summer,ON,05/06/01 00 Description • Parameter p3 is not available when p2 is OFF. • The SS command can be used on the RD100B with system version 1.02 or earlier. SK Sets the computation constant (/M1 option). Syntax SK p1,p2 p1 Constant number (K01 to K30) p2 Constant (up to 11 characters) The range is –9.9999E+29 to –1.0000E–30, 0, 1.0000E–30 to 9.9999E+29. (The + sign of “E+” can be omitted.) Query SK[ p1]? Example Set 1.0000E−10 to constant K01. SK K01,1.0000E−10 Description This command cannot be specified while computation is in progress. SJ Sets the timer used in TLOG computation (/M1 option). Syntax SJ p1,p2,p3 p1 Computation channel number p2 Timer number (Periodic, 1, 2) p3 Sum scale (for TLOG.SUM) OFF Integrates the data per scan interval. /s Integrates the physical amount that are in unit of /s. /min Integrates the physical amount that are in unit of /min. /h Integrates the physical amount that are in unit of /hour. /day Integrates the physical amount that are in unit of /day. Query SJ[ p1]? Example Enable timer 1 on computation channel 0B. No sum scale designation. SJ 0B,1,OFF Description • This command cannot be specified while computation is in progress. • About p3 The data for sum computation are sampled every scan interval. For data with units such as /s, /min, /h, and /day as in a flow rate, the data can be summed over the unit time as shown below. Parameter p3 is valid only for sum values. OFF Σ (measured value) /s Σ (measured value) × scan interval /min Σ (measured value) × scan interval/60 /h Σ (measured value) × scan interval/ 3600 /day Σ (measured value) × scan interval/ (3600×24) The unit of the scan interval is seconds. CM Sets the communication input data (/M1 option). Syntax CM p1,p2 p1 Communication input data number (see section 4.3) p2 Communication input data The selectable range is –9.9999E+29 to – 1.0000E–30, 0, 1.0000E–30 to 9.9999E+29. (The + sign of “E+” can be omitted.) Query CM? Example Set 1.0000E–10 to communication input data number C01. CM C01,1.0000E−10 FR Sets the interval for acquiring data to the FIFO buffer Syntax FR p1 p1 Pen model: 125ms, 250ms, 500ms, 1s, 2s, 2.5s, 5s, 10s Dot model: 1s, 2s, 2.5s, 5s, 10s Query FR? Example Set the acquiring interval to the FIFO buffer to 1 s. FR 1s Description • Set the acquiring interval to an integer multiple of the scan interval that is greater than the scan interval. • The scan interval on the pen model is 125 ms. • The scan interval on the dot model varies depends on the integration time of the A/D converter as follows: When the integration time is 16.7 ms or 20 ms; 6 channels: 1 s 12, 18, or 24 channels: 2.5 s 4.4 Setting Commands

When the integration time is 100 ms;

6 channels: 2.5 s 12 channels: 5 s 18 and 24 channels: 10 s VD Sets the data display screen. On screens without detailed parameters Syntax VD p1,p2 p1 Screen number (01 to 15) p2 Display type 4CH bargraph 4-channel bar graph display (pen model) 6CH bargraph 6-channel bar graph display (RD100B dot model) Channel alarm status Channel alarm status display Time/Chart speed Date/Time/Chart speed display DI/DO DI/DO status display STATUS Status display System System display Light out Screen OFF SKIP Skip Query VD[ p1]? Example Assign the status display to screen 02. VD 02,STATUS On screens with the displayed channel switching interval Syntax VD p1,p2,p3 p1 Screen number (01 to 15) p2 Display type 1CH digital 1-channel digital display 2CH digital 2-channel digital display 4CH digital 4-channel digital display 6CH digital 6-channel digital display (dot model) 12CH digital 12-channel digital display (RD1800B 12, 18 and 24 dot model) 1CH digital+1CH bargraph 1-channel digital display + 1 channel bar graph display 1CH digital+4CH bargraph 1-channel digital display + 4 channel bar graph display (pen model) 2CH digital+2CH bargraph 2-channel digital display + 2 channel bar graph display Tag_1CH digital 1-channel digital display (tag) Tag_2CH digital 2-channel digital display (tag) Tag_1CH digital+1CH bargraph 1-channel digital display + 1 channel bar graph display (tag) Tag_1CH digital+4CH bargraph 1-channel digital display + 4 channel bar graph display (tag, pen model) p3 Displayed channel switching interval MANUAL Fixed display channels, data update rate (pen model): 2 s, data update rate (dot model): scan interval AUTO1S Switch the displayed channels and data every second. AUTO2S Switch the displayed channels and data every 2 seconds. AUTO3S Switch the displayed channels and data every 3 seconds. AUTO4S Switch the displayed channels and data every 4 seconds. AUTO5S Switch the displayed channels and data every 5 seconds. Query VD[ p1]? Example Assign the 2-channel digital display to screen 04 and automatically switch the displayed channels every 5 seconds. VD 04,2CH digital,AUTO5S For flag display Syntax VD p1,p2,p3 p1 Screen number (01 to 15) p2 Display type FLAG Flag display (fixed) p3 Display ON/OFF for each channel Specify the ON/OFF state of each channel with 1 or 0 (see the explanation). Query VD[ p1]? Example 1 On the 6-dot model, assign the flag display to screen 03 and display the flags of channel 01 and 02. VD 03,FLAG,110000 Example 2 On the 2-pen model with the computation function (/M1 option), assign the flag display to screen 03 and display the flags of measurement channel 02 and computation channels 0A, 0B, 0E, and 0F. VD 03,FLAG,01-11001100 4.4 Setting Commands

Description Use the format below to specify the display ON/

OFF state of each channel. • List the values one after another for all channels and separate the measurement channels and computation channels with a hyphen. • Channels cannot be omitted. • The characters after the hyphen are valid only on models with the computation function (/M1 option). For multiple display (display in which different screens can be assigned to the top and bottom sections Syntax VD p1,p2,p3,p4,p5,p6,p7,p8,p9,p10,p11,p12 p1 Screen number (01 to 15) p2 Display type Multiple display Display in which different screens can be assigned to the top and bottom sections p3 Top section display type 1CH digital 1-channel digital display 2CH digital 2-channel digital display 3CH digital 3-channel digital display (RD1800B) TIME Date/Time (RD100B) Chart speed Chart speed (RD100B) TIME/Chart speed Date/Time/Chart speed (RD1800B) Channel alarm status Channel alarm status display STATUS Status display Light out Screen OFF Tag_1CH digital 1-channel digital display (tag) Note Parameters that become invalid due to p3, p4, p8, or p9 setting are skipped, and the next parameter is brought forward. p4 Displayed channel switching interval Condition: Set this parameter when p3 is 1CH digital or 2CH digital. MANUAL Fixed display channels, data update rate (pen model): 2 s, data update rate (dot model): scan interval AUTO1S Switch the displayed channels and data every 1 second. AUTO2S Switch the displayed channels and data every 2 seconds. AUTO3S Switch the displayed channels and data every 3 seconds. AUTO4S Switch the displayed channels and data every 4 seconds. AUTO5S Switch the displayed channels and data every 5 seconds. p5 Channel number Condition: This parameter can be specified when p3 is 1CH digital, 2CH digital, or Tag_1CH digital and p4 is MANUAL. p6 2nd channel number Condition: This parameter is specified when p3 is 2CH digital and p4 is MANUAL. p7 3rd channel number Condition: This parameter is specified when p3 is 3CH digital and p4 is MANUAL. p8 Bottom section display type Same as p3 p9 Displayed channel switching interval Same as p4 p10 Channel number Same as p5 p11 2nd channel number Same as p6 p12 3rd channel number Same as p7 Query VD[ p1]? Example Assign the display in which different screens can be assigned to the top and bottom sections to screen 09. Set the top section to status display and the bottom section to 1-channel digital display. Switch the displayed channel every 3 seconds (parameters p5 to p7, p10, and p12 explained above are omitted). VD 09,Multiple display,STATUS,1CH digital,AUTO3S 4.4 Setting Commands

4.5 Basic Setting Commands

4.5 Basic Setting Commands • In order to activate the settings that are changed using the basic setting commands, the settings must be saved using the YE or XE command. • The settings that are returned in response to a query in the basic setting mode will contain the new settings even if they are not saved. Note • The settings that are changed using the YS/YB/YA/YN/ YD/YQ/YK command and saved using the XE command are activated after power-cycling the recorder. • When the YE command is executed, communication is dropped. XA Sets alarm related settings. Syntax XA p1,p2,p3,p4,p5,p6,p7,p8,p9,p10 p1 Fault diagnosis output ON/OFF (ON, OFF) p2 Reflash operation ON/OFF (ON, OFF) p3 Relays that are to operate using AND logic NONE None (all relays operate using OR logic) I01 I01 I01-I02 I01, I02 I01-I03 I01 to I03 I01-I04 I01 to I04 I01-I05 I01 to I05 I01-I06 I01 to I06 I01-I11 I01 to I11 (RD1800B) I01-I12 I01 to I12 (RD1800B) I01-I13 I01 to I13 (RD1800B) I01-I14 I01 to I14 (RD1800B) I01-I15 I01 to I15 (RD1800B) I01-I16 I01 to I16 (RD1800B) I01-I21 I01 to I21 (RD1800B) I01-I22 I01 to I22 (RD1800B) I01-I23 I01 to I23 (RD1800B) I01-I24 I01 to I24 (RD1800B) I01-I25 I01 to I25 (RD1800B) I01-I26 I01 to I26 (RD1800B) I01-I31 I01 to I31 (RD1800B) I01-I32 I01 to I32 (RD1800B) I01-I33 I01 to I33 (RD1800B) I01-I34 I01 to I34 (RD1800B) I01-I35 I01 to I35 (RD1800B) I01-I36 I01 to I36 (RD1800B) p4 Energize/De-energize the relay ENERGIZE Energize the relay when an alarm is detected DE_ENERGIZE De-energize the relay when an alarm is detected p5 Hold/Not hold the relay HOLD Hold the relay output until an alarm acknowledge operation is executed NONHOLD Reset the relay output when the alarm is cleared. p6 Hold/Not hold the alarm status display HOLD Hold the display until an alarm acknowledge operation is executed NONHOLD Clear the display output when the alarm is cleared. p7 Interval for the high limit on rate-of-change alarm (01 to 15) p8 Interval for the low limit on rate-of-change alarm (01 to 15) p9 Alarm hysteresis on measurement channels (OFF, 0.1%, 0.2%, 0.3%, 0.4%, 0.5%, 0.6%, 0.7%, 0.8%, 0.9%, or 1.0%) p10 Alarm hysteresis on computation channels (OFF, 0.1%, 0.2%, 0.3%, 0.4%, 0.5%, 0.6%, 0.7%, 0.8%, 0.9%, or 1.0%) Query XA? Example Enable fault diagnosis output. Disable reflash and AND operations. Set the relay operation to energize and hold. Set the alarm status display to hold. Set the interval for the high limit of rate- of-change alarm to 10, the interval for the low limit of rate-of-change alarm to 12, the measurement alarm hysteresis to 0.5%, and the computation alarm hysteresis to OFF. XA ON,OFF,NONE,ENERGIZE,HOLD,HOLD, 10,12,0.5%,OFF Description • The interval for the high limit of rate-of-change alarm is equal to “scan interval × p7” and the interval for the low limit of rate-of-change alarm is equal to “scan interval × p8.” • Parameter p10 can be specified on models with the computation function (/M1 option). • For the details on the settings, see the Recorder User’s Manual. XI Sets the A/D integral time. Syntax XI p1 p1 Integration time of the A/D converter AUTO Automatically set in synch with the power supply frequency. 50HZ 12.5 ms 60HZ 16.7 ms 100MS 100 ms (dot model) Query XI? Example Set the A/D integral time to 50 Hz. XI 50HZ Description 100 ms is available only on the dot model.

Sets the burnout detection.

Syntax XB p1,p2 p1 Channel number p2 The procedure taken when a sensor burnout is detected OFF Disable the burnout detection. UP Set the recording off the scale to the right when a burnout is detected. DOWN Set the recording off the scale to the left when a burnout is detected. Query XB[ p1]? Example Set the recording off the scale to the right when a sensor burnout is detected on channel 01. XB 01,UP XJ Sets the RJC. When using the internal compensation circuit Syntax XJ p1,p2 p1 Channel number p2 Reference junction compensation selection (INTERNAL) Query XJ[ p1]? Example Use the internal compensation circuit on channel 01. XJ 01,INTERNAL When using an external RJC Syntax XJ p1,p2,p3 p1 Channel number p2 Reference junction compensation selection (EXTERNAL) p3 Compensation voltage (–20000 to 20000) [µV] Query XJ[ p1]? Example Set the reference junction compensation of channel 02 to external and set the compensation voltage to 0 µV. XJ 02,EXTERNAL,0 Description The unit of p3 is µV (microvolts). UC Changes the dot color (dot model). Syntax UC p1,p2 p1 Channel number p2 Dot color PURPLE RED GREEN BLUE BROWN BLACK Query UC[ p1]? Example Set the dot color of channel 06 to purple. UC 06,PURPLE Description On models with the computation function (/M1 option), the dot color of computation channels can be changed. UO Sets the pen offset compensation (pen model). Syntax UO p1 p1 Pen offset compensation ON/OFF (ON, OFF) Query UO? Example Use the pen offset compensation. UO ON UP Sets the items to be printed. Pen model Syntax UP p1,p2,p3,p4,p5,p6 p1 Channel number/tag selection CHANNEL Print the channel number TAG Print the tag p2 Alarm printout ON1 Print at alarm occurrence and release ON2 Print at alarm occurrence OFF Do not print p3 Record start time printout ON/OFF (ON, OFF) p4 New chart speed printout ON/OFF (ON, OFF) p5 Scale printout ON/OFF (ON, OFF) p6 Recording color printout ON/OFF (ON, OFF) Query UP? Example Print tags. Print all items. UP TAG,ON1,ON,ON,ON,ON Dot model Syntax UP p1,p2,p3,p4,p5,p6 p1 Channel number/tag selection CHANNEL Print the channel number TAG Print the tag p2 Channel number printout ON/OFF (ON, OFF) by the trend recording p3 Alarm printout ON1 Print at alarm occurrence and release ON2 Print at alarm occurrence OFF Do not print p4 Record start time printout ON/OFF (ON, OFF) p5 New chart speed printout ON/OFF (ON, OFF) p6 Scale printout ON/OFF (ON, OFF) Query UP? Example Print the channel numbers. Print all items. UP CHANNEL,ON,ON1,ON,ON,ON UR Sets the periodic printout interval. Syntax UR p1,p2,p3,p4 p1 Print interval mode Auto Automatically set the interval according to the chart speed Manual Specify the interval p2 Reference time (00 to 23 [hour]) p3 Interval (10min, 12min, 15min, 20min, 30min, 1h, 2h, 3h, 4h, 6h, 8h, 12h, 24h) (when p1 is Manual) 4.5 Basic Setting Commands

4.5 Basic Setting Commands

p4 Periodic printout mode OFF Disable periodic printout INST Print instantaneous values. REPORT Print the report data over the interval. Query UR? Example Carry out periodic printout every 2 hours with hour 0 as the reference. Print the measured values (instantaneous values) at each interval. UR Manual,00,2h,INST Description • When p1 is set to Auto, the periodic printout interval synchronizes to the chart speed. • If p4 is set to REPORT, set the type of report data on each channel using the UM command. UM Sets the types of report data that are output to the periodic printout. Syntax UM p1,p2,p3 p1 Channel number p2 Type of report data INST Instantaneous value AVE Average value MIN Minimum value MAX Maximum value SUM Sum value MIX Average + minimum + maximum values p3 Sum scale OFF Integrates the data per scan interval. /s Integrates the physical amount that are in unit of /s. /min Integrates the physical amount that are in unit of /min. /h Integrates the physical amount that are in unit of /hour. /day Integrates the physical amount that are in unit of /day. Query UM[ p1]? Example Print the average values of channel 03 using periodic printout. UM 03,AVE Description • This setting is possible when printing of report data (p4 is REPORT) is specified using the UR command. • About p3 The data for sum computation are sampled every scan interval. For data with units such as /s, /min, /h, and /day as in a flow rate, the data can be summed over the unit time. Parameter p3 is valid only for sum values. • On models with the computation function (/M1 option), computation channels can be specified. UB Sets the display mode of the bar graph. Syntax UB p1,p2 p1 Channel number p2 Bar graph display mode NORMAL The reference position is set to the smaller of the two values, leftmost value and rightmost value. CENTER The reference position is set to the 50% position. Query UB[ p1]? Example Display channel 01 using a bar graph with the reference position set to the 50% position. UB 01,CENTER Description On models with the computation function (/M1 option), computation channels can be specified. UI Sets whether to use moving average (dot model). Syntax UI p1 p1 Use/Not use moving average (USE, NOT) Query UI? Example Use moving average. UI USE UJ Sets whether to use the input filter (pen model). Syntax UJ p1 p1 Use/Not use the input filter (USE, NOT) Query UJ? Example Use the input filter. UJ USE UK Sets whether to use of partial expanded recording. Syntax UK p1 p1 Use/Not use partial expanded recording (USE, NOT) Query UK? Example Use partial expanded recording. UK USE UL Selects the display/record language. Syntax UL p1 p1 Language (ENGLISH, JAPANESE) Query UL? Example Use English. UL ENGLISH XN Selects the date format. Syntax UL p1 p1 Date format for displaying and printing Y/M/D: (example) 2005/08/31 M/D/Y: (example) 08/31/2005

D/M/Y: (example) 31/08/2005

D.M.Y: (example) 31.08.2005 M.D.Y: (example) Aug.31.2005 Query XN? Example Set to the "2005/08/31" format. XN Y/M/D Description This setting applies to the format of the date shown on the display and the date printed on the periodic printout, manual printout, alarm printout, message printout, recording start printout, and new chart speed printout. Note How this setting applies to the time printout format of the alarm printout, message printout, recording start printout, and new chart speed printout: The setting specifies the format of the "M/D" and "Y/M/D" section when the time printout format is set to "M/D H:M," "M/D H:M:S," or "Y/M/ D H:M:S." XT Selects the temperature unit. Syntax XT p1 p1 Temperature unit C °C F °F Query XT? Example Use °F. XT F UF Sets whether to use the extended functions. Syntax UF p1,p2,p3,p4 p1 Bias function (USE, NOT) p2 Square root low-cut function (USE, NOT) p3 1-5V input low-cut function (USE, NOT) p4 Alarm delay function (USE, NOT) Query UF? Example Use all the extended functions. UF USE,USE,USE,USE Description • The input offset is set using the VB command. • The low-cut function is set using the SR command. • The delay alarm is set using the SA and BD commands. UT Selects the time printout format. Syntax UT p1,p2,p3,p4 p1 Time printout format of the alarm printout The available selections are the same as those of p2. None is not available. p2 Time printout format of the message printout HH:MM Hour:Minute HH:MM:SS Hour:Minute:Second M/D H:M Month Day Hour:Minute M/D H:M:S Month Day Hour:Minute: Second YMD H:M:S Month Day Year Hour:Minute: Second None No time printout p3 Time printout format of the record start time printout The available selections are the same as those of p2. None is not available. p4 Time printout format of the new chart speed printout The available selections are the same as those of p2. None is not available. Query UT? Example Set the all time printouts to Hour:Minute format. UT HH:MM,HH:MM,HH:MM,HH:MM XR Sets the remote control input (/R1 option). Syntax XR p1,p2 p1 Remote control input terminal number (1 to 5) p2 Action NONE No action Record On/Off Start/Stop recording. Chart speed Change the chart speed. Time adjust Reset the internal clock to the nearest hour. Math start/stop Start/Stop computation. Math reset Reset computation. Manual print Execute manual print. Alarm Ack Execute alarm acknowledge. Message1 Print message 1 Message2 Print message 2 Message3 Print message 3 Message4 Print message 4 Message5 Print message 5 Query XR[ p1]? Example Assign the printout of message 2 to the remote control input of terminal number 1. XR 1,Message2 Description Math start/stop and Math reset can be specified on models with the computation function (/M1 option). YS Sets the RS-422A/485 interface (/C3 option). Syntax YS p1,p2,p3,p4,p5 p1 Address (1 to 32) p2 Baud rate (1200, 2400, 4800, 9600, 19200, 38400) p3 Data length (7, 8) p4 Parity check (ODD, EVEN, NONE) p5 Protocol (NORMAL, MODBUS) 4.5 Basic Setting Commands

Set the address to 2, the baud rate to 9600, the

data length to 8, the parity check to ODD, and the NORMAL protocol. YS 2,9600,8,ODD,NORMAL Description • The settings specified by this command and saved using the XE command take effect after the recorder is power cycled. • If p5 is set to MODBUS, Modbus slave is selected. XQ Sets the TLOG timer (/M1 option). When not using the timer Syntax XQ p1,p2 p1 Timer number (1 or 2) p2 Timer type (OFF) Query XQ[ p1]? Example Disable the number 1 timer. XQ 1,OFF When using an absolute timer Syntax XQ p1,p2,p3,p4,p5,p6 p1 Timer number (1 or 2) p2 Timer type (ABSOLUTE) p3 Interval (10min, 12min, 15min, 20min, 30min, 1h, 2h, 3h, 4h, 6h, 8h, 12h, 24h) p4 Reference time (fixed to HH format) HH Hour (00 to 23) p5 Reset/not reset the data when the timer expires (ON/OFF) p6 Printout ON/OFF (ON, OFF) Query XQ[ p1]? Example Set an absolute timer to timer number 1. Set the interval to 30 minutes, the reference time to hour 7, reset the data when the timer expires, and disable printout. XQ 1,ABSOLUTE,30min,07,ON,OFF Description Each time the interval specified by p3 elapses from the time specified by p4, the operations set with p5 and p6 are performed. When using the relative timer Syntax XQ p1,p2,p3,p4,p5 p1 Timer number (1 or 2) p2 Timer type (RELATIVE) p3 Interval (fixed to HH:MM format) HH Hour (00 to 24) MM Minute (00 to 59) Set the interval in the range 00:01 to 24:00 p4 Reset/not reset the data when the timer expires (ON/OFF) p5 Printout ON/OFF (ON, OFF) Query XQ[ p1]? Example Set a relative timer to timer number 1. Set the interval to 1 hour 15 minutes, reset the data when the timer expires, and disable printout. XQ 1,RELATIVE,01:15,ON,OFF Description Each time the interval specified by p3 elapses from the time the computation is started, the operations set with p4 and p5 are performed. UN Changes the assignment of channels to the recording pen (pen model, /M1 option). Syntax UN p1,p2 p1 Pen number (1 to 4) p2 Channel number Query UN[ p1]? Example Assign computation channel 0A to pen number 4. UN 4,0A US Sets the computation error procedure (/M1 option). Syntax US p1,p2 p1 Procedure taken when an error occurs. +OVER Handle error data as +OVER −OVER Handle error data as –OVER p2 Procedure taken when the “input over” is detected (procedure taken when an “input over” value is applied to TLOG.SUM or TLOG.AVE computation) SKIP Do not use the data for computation. LIMIT Use the limit value given by the recorder for computation. Query US? Example When the computed result is in error, handle the error data as +OVER. Use the limit value given by the recorder for computation instead of the “input over” value. US +OVER,LIMIT YB Sets the host name and domain name (/C7 option). Syntax YB p1,p2 p1 Host name (up to 64 characters) p2 Domain name (up to 64 characters) Query YB? Example Set the host name to “ABC” and the domain name to “recorder.co.jp.” YB ABC,recorder.co.jp Description The settings specified by this command and saved using the XE command take effect after the recorder is power cycled. YA Sets the IP address (/C7 option). Syntax YA p1,p2,p3 p1 IP address (0.0.0.0 to 255.255.255.255) p2 Subnet mask (0.0.0.0 to 255.255.255.255) p3 Default gateway (0.0.0.0 to 255.255.255.255) Query YA? 4.5 Basic Setting Commands

Set the IP address to 192.168.111.24, the subnet

mask to 255.255.255.0, and the default gateway to 0.0.0.0. YA 192.168.111.24,255.255.255.0, 0.0.0.0 Description The settings specified by this command and saved using the XE command take effect after the recorder is power cycled. YN Sets the DNS (/C7 option). When not using the DNS Syntax YN p1 p1 Use/Not use the DNS (OFF) Query YN? Example Do not use the DNS. YN OFF When using the DNS Syntax YN p1,p2,p3,p4,p5 p1 Use/Not use the DNS (ON) p2 Address of the primary DNS server (0.0.0.0 to 255.255.255.255) p3 Address of the secondary DNS server (0.0.0.0 to 255.255.255.255) p4 Domain suffix 1 (up to 64 characters) p5 Domain suffix 2 (up to 64 characters) Query YN? Example Use the DNS server at 192.168.0.1. YN ON,192.168.0.1 Description The settings specified by this command and saved using the XE command take effect after the recorder is power cycled. YD Sets whether to use the login function via communication (/C7 option). Syntax YD p1 p1 Use/Not use the login function via communication (USE, NOT) Query YD? Example Use the login function via communication. YD USE Description The settings specified by this command and saved using the XE command take effect after the recorder is power cycled. YQ Sets the communication timeout (/C7 option). When not using the timeout Syntax YQ p1 p1 Enable/Disable communication timeout (OFF) Query YQ? Example Disable timeout. YQ OFF When using the timeout Syntax YQ p1,p2 p1 Enable/Disable communication timeout (ON) p2 Timeout time (1 to 120) [minutes] Query YQ? Example Enable communication timeout and set the timeout period to 3 min. YQ ON,3 Description The settings specified by this command and saved using the XE command take effect after the recorder is power cycled. YK Sets keepalive (/C7 option). Syntax YK p1 p1 Enable/Disable keepalive (ON, OFF) Query YK? Example Disable keepalive. YK OFF Description The settings specified by this command and saved using the XE command take effect after the recorder is power cycled. UA Sets the record position. Pen model Syntax UA p1,p2,p3 p1 Record position selection ZERO 0% position FULL 100% position p2 Pen number (1 to 4) p3 Record position adjustment value When p1 = ZERO RD100B: An integer between 0 and 70 RD1800B: An integer between 0 and 180 When p1 = FULL RD100B: An integer between –45 to 15 (reference value: 3026) RD1800B: An integer between –165 to 165 (reference value: 5447) Example Adjust the 0% position of pen 1. Set the record position adjustment value to 20. UA ZERO,1,20 Description • Check the recorded result and correct the record position adjustment value. • To end the adjustment, execute the UY0 command. If you do not end the adjustment, you cannot change the execution mode. • The unit for p3 is 1/30 mm. 4.5 Basic Setting Commands

Record position selection

ZERO 0% position FULL 100% position Hysteresis The difference in the record position according to the operating direction of the printer carriage p2 Record position adjustment value When p1 = Hysteresis An integer between –7 to 7 When p1 = ZERO RD100B: An integer between 0 and 15 RD1800B: An integer between 0 and 50 When p1 = FULL RD100B: An integer between –30 to 30 (reference value: 1000) RD1800B: An integer between –50 to 50 (reference value: 1800) Example Adjust the 100% position. Set the record position adjustment value to 25. UA FULL,25 Description • Carry out the adjustment in the following order: P1 = Hysteresis, ZERO, and then FULL. • Check the recorded result and correct the record position adjustment value. • To end the adjustment, execute the UY0 command. If you do not end the adjustment, you cannot change the execution mode. • The unit for p2 is dot (0.1 mm). YE Exits from Basic Setting mode. When the YE command is executed, communication is dropped. Syntax YE p1 p1 Apply/Discard the settings STORE Apply the settings ABORT Discard the settings Example Apply the basic settings. YE STORE Description Applies the settings changed with the basic setting commands. XE Exits from Basic Setting mode. Communication is not dropped when the XE command is executed. Syntax XE p1 p1 Apply/Discard the settings STORE Apply the settings ABORT Discard the settings Example Apply the basic settings. XE STORE Description The settings specified by the following commands and saved using the XE command take effect after the recorder is power cycled. YS, YB, YA, YN, YD, YQ, and YK 4.5 Basic Setting Commands

Switches the execution mode.

Syntax DS p1 p1 Mode 0 Run mode 1 Basic Setting mode Example Switch to Basic Setting mode. DS 1 Description The execution mode cannot be changed to Basic Setting Mode while recording or computation is in progress. PS Starts/Stops recording. Syntax PS p1 p1 Start/Stop recording. 0 Start 1 Stop Example Start recording. PS 0 UD Switches the screen/switches the channel. Returning to the data display screen Returns from the Setting mode screen, the screen that appears when the FUNC key is pressed, or the screen that appears when the DISP MENU key is pressed back to the measurement data display screen. Syntax UD p1 p1 Fixed to 0. Example Return to the data display screen. UD 0 Displaying the specified data display screen Syntax UD p1,p2 p1 Fixed to 1. p2 Screen number (1 to 15) Example Display data display screen 2. UD 1,2 Switching the display channel (manual switching) Syntax UD p1 p1 Fixed to 2. Example Switch the display channel. UD 2 Description • An error results if the specified screen is set to SKIP for UD1. • UD2 is valid on screens whose display channel is set to manual switching. AK Executes alarm acknowledge (Alarm ACK). Syntax AK p1 p1 Executes alarm acknowledge (0) Example Execute alarm acknowledge. AK 0 TL Starts/stops/resets computation (/M1 option). Syntax TL p1 p1 Operation type 0 Computation start 1 Computation stop 2 Computation reset Example Start the computation. TL 0 MP Starts/Stops manual print. Syntax MP p1 p1 Operation type 0 Manual print start 1 Manual print stop Example Start manual print. MP 0 LS Starts/Stops the list (setting information) printout. Syntax LS p1 p1 Operation type 0 List print start 1 List print stop Example Start list print. LS 0 Description List print refers to printing of settings of Setting mode. SU Starts/Stops the setup list (basic setting information) printout. Syntax SU p1 p1 Operation type 0 Setup list print start 1 Setup list print stop Example Start setup list print. SU 0 Description Setup list print refers to printing of settings of Basic Setting mode. MS Prints the message. Syntax MS p1 p1 Message number (1 to 5) Example Print the message of message number 3. MS 3 Description The message string is set with the SG command. AC Clears the alarm printout buffer. Syntax AC p1 p1 Clear the alarm printout buffer (0) Example Clear the alarm printout buffer. AC 0 4.6 Control Commands

Clears the message printout

buffer. Syntax MC p1 p1 Clear the message printout buffer (0) Example Clear the message printout buffer. MC 0 VG Resets the report data of the periodic printout. Syntax VG p1 p1 Operation type 2 Reset the report data of the periodic printout. Example Reset the report data of the periodic printout. VG 2 Description This setting is valid when the recorder is set to print the report data using periodic printout. YC Initializes settings. Syntax YC p1 p1 Initialization type 0 Initialize the Setting mode and Basic Setting mode settings. 1 Initialize the Setting mode settings. Example Initialize the Setting mode and Basic Setting mode settings. YC 0 UY Stops the record position adjustment. Syntax UY p1 p1 Fixed to 0. Query UY? Example Stop the record position adjustment. UY 0 Description Returns the execution status of the record position adjustment in response to a query. 0: Stopped, 1: In progress 4.7 Output Commands BO Sets the byte output order. Syntax BO p1 p1 Byte order 0 Outputs the data MSB first. 1 Outputs the data LSB first. Query BO? Example Output the data MSB first. BO 0 Description This command applies to the byte order of numerical data during BINARY output. CS Sets the checksum (/C3 option). Syntax CS p1 p1 Use/Not use the checksum 0 Not use 1 Use Query CS? Example Use the checksum. CS 1 Description This command can be used only on the RS- 422A/485 communication interface. IF Sets the status filter. Syntax IF p1 p1 Status filter value (0.0.0.0 to 255.255.255.255) Query IF? Example Set the status filter value to 1.0.4.0. IF 1.0.4.0 Description For details, see chapter 6. Note Initialization of BO/CS/IF Command Settings • For serial communications Settings entered using the BO/CS/IF commands revert to their initial values when the recorder is reset (when the recorder is power cycled, or the user exits the basic setting mode with the YE command). • Byte output order, checksum: 0 • Status filter: 255.255.255.255 If the recorder is reset, you must restore these settings. • For Ethernet communications Settings entered using the BO/IF commands revert to their initial values when the connection to the recorder is cut. After reconnecting the recorder, you must reenter the settings. CC Disconnects an Ethernet connection (/C7 option). Syntax CC p1 p1 Disconnect the connection (0) 4.6 Control Commands/4.7 Output Commands

Disconnect the connection.

CC 0 FE Outputs decimal point position, unit information, and setup data. Syntax FE p1,p2,p3 p1 Output data type 0 Setup data of Setting mode 1 Decimal point position and unit information 2 Setup data of Basic Setting mode 4 Setting data file p2 First output channel number p3 Last output channel number Example Output the setup data of the Setting commands of channel 01 through 04. FE 0,01,04 Description • Be sure to set p2 and p3 so that p3 is greater than or equal to p2. • The settings of p2 and p3 are valid when p1 = 0, 1, or 2. • The setting data file can be viewed using the configuration software. FD Outputs the most recent measured/computed data. Syntax FD p1,p2,p3 p1 Output data type 0 Output the most recent measured/ computed data in ASCII format 1 Output the most recent measured/ computed data in BINARY format p2 First output channel number p3 Last output channel number Example Output the most recent measured/computed data from channel 01 to 04 in ASCII format. FD 0,01,04 Description • The most recent measured/computed data indicates the most recent measured/computed data when the recorder receives the FD command. • Be sure to set p2 and p3 so that p3 is greater than or equal to p2. FY Outputs the statistical computation results. Syntax FY p1,p2,p3 p1 Output data type Inst Output the most recent periodic printout data (instantaneous value) Report Output the statistical calculation data of periodic printout (report data) Tlog1 Output the data at the most recent timeout of TLOG timer 1 Tlog2 Output the data at the most recent timeout of TLOG timer 2 p2 First output channel number p3 Last output channel number Example Outputs the most recent periodic printout data of channel 01 to 04. FY Inst,01,04 Description Tlog1 and Tlog2 are valid on models with the computation function (/M1 option). FF Outputs the FIFO data. Syntax FF p1,p2,p3,p4 p1 Operation type GET Output the data starting from the next to the previous read position RESEND Retransmit the previous output RESET Set the read position (block) to the most recent acquire position (block) GETNEW Output the most recent data p2 First output channel number p3 Last output channel number p4 The upper limit of number of blocks that are to be loaded Pen model 1 to 240 Dot model 1 to 60 If the measured/computed data is less than the specified number of blocks, only the available data is transmitted. Example Output two blocks of FIFO data from channels 01 to 06. FF GET ,01,06,2 Description • The FIFO buffer is of a circular type which overwrites from the oldest data when it is full. • The FR command is used to set the acquiring interval. • There are two FIFO data output formats. Logging output (GET) Output the specified number of blocks (p4) of FIFO data starting from the next to the previous read position (block). Make sure to read the data within the following buffer period to prevent data dropouts. Pen model FIFO buffer length 240 blocks Maximum buffer period 240 intervals Dot model FIFO buffer length 60 blocks Maximum buffer period 60 intervals 4.7 Output Commands

Newest value output (GETNEW)

Output the specified number of blocks (p4) of FIFO data back starting from the recent acquire position (block). • Parameters p2, p3, and p4 are valid when p1 is set to GET or GETNEW. • If p4 is omitted, all the data of all blocks acquired in the FIFO buffer are output. • Be sure to set p2 and p3 so that p3 is greater than or equal to p2. • For the output flow of FIFO data, see appendix 4. IS Outputs status information. Syntax IS p1 p1 Output status information (0) Example Output status information. IS 0 Description The output status can be masked using the status filter (IF command). FU Outputs user information. Syntax FU p1 p1 Output user information (0) Example Output user information. FU 0 Description Outputs the information of the user currently connected to the recorder. 4.8 RS-422A/485 Dedicated Commands ESC O Opens the instrument. The ASCII code of ESC is 1BH. Syntax ESC O p1 p1 Instrument address (01 to 32) Example Open the instrument at address 01. ESC O 01 Description • Specifies the address of the instrument with which to communicate. • Only one instrument can be opened at any given time. • When an instrument is opened with the ESC O command, any other instrument that is currently open is automatically closed. • When this command is received correctly, the recorder transmits the data “ESC 0 xx” (xx: Instrument’s address). • Use CR+LF for the terminator. LF cannot be used. ESC C Closes the instrument. The ASCII code of ESC is 1BH. Syntax ESC C p1 p1 Instrument address (01 to 32) Example Close the instrument at address 01. ESC C 01 Description • Clears the current connection with the instrument. • When this command is received correctly, the recorder transmits the data “ESC C xx” (xx: Instrument’s address). • Use CR+LF for the terminator. LF cannot be used. 4.7 Output Commands/4.8 RS-422A/485 Dedicated Commands

Commands (Available when

using the maintenance/test server function via Ethernet communications) close Disconnects the connection between other instruments. Syntax close,p1,p2:p3 p1 Port on the recorder side (0 to 65535) p2 IP address on the PC side (0.0.0.0 to 255.255.255.255) p3 Port on the PC side (0 to 65535) Example close,34159,192.168.111.24:1054 E0 Description This command cannot be used to disconnect a server port. Also, it cannot disconnect the recorder being operated. Use the quit command for this purpose. con Outputs connection information. Syntax con Example con EA 04/10/01 12:34:56 Active connections Proto Local Address Foreign Address State TCP 192.168.111. 24:34159 192.168.111. 24:1053 ESTABLISHED TCP 0. 0. 0. 0:34155 0. 0. 0. 0: 0 LISTEN TCP 0. 0. 0. 0:34159 0. 0. 0. 0: 0 LISTEN TCP 0. 0. 0. 0:34150 0. 0. 0. 0: 0 LISTEN EN TCP Protocol used. Local Address The recorder’s socket address. Displays “IP address:port number.” Foreign Address The destination socket address. Displays “IP address:port number.” State Connection status. ESTABLISHED Connection established. 4.9 Maintenance/Test Commands eth Outputs Ethernet statistical information. Syntax eth Example eth EA 04/10/01 12:34:56 Ethernet Statistics Name In Pkt In Err Out Pkt Out Err 16 Coll lo0 0 0 0 0 0 mb0 74 0 64 0 0 EN help Outputs help. Syntax help [,p1] p1 Command name (close, con, eth, help, net, quit) Example help EA con - echo connection information eth - echo ethernet information help - echo help net - echo network status quit - close this connection EN net Outputs network statistical information. Syntax net Example net EA 04/10/01 12:34:56 Network Status APP: power on time = 00/00/00 12:34:56 APP: applalive = disable APP: genedrops = 0 APP: diagdrops = 0 APP: ftpsdrops = 0 TCP: keepalive = 30 s TCP: connects = 14 TCP: closed = 0 TCP: timeoutdrop = 0 TCP: keepdrops = 0 TCP: sndtotal = 53 TCP: sndbyte = 0 TCP: sndrexmitpack = 0 TCP: sndrexmitbyte = 1 TCP: rcvtotal = 0 TCP: rcvbyte = 0 DLC: 16 collisions = 0 EN

Keepalive check cycle.

TCP: connects Total number of connections established. TCP: closed Total number of dropped connections. TCP: timeoutdrop Total number of dropped connections due to TCP retransmission timeout. When the transmitted packet (the unit of transmitted data) is not received, the packet is automatically retransmitted at a predetermined time interval. If the packet is not received after 14 retransmissions, timeout occurs and the connection is dropped. TCP: keepdrops Total number of dropped connections due to TCP keepalive timeout. TCP: sndtotal Total number of transmitted packets. TCP: sndbyte Total number of transmitted bytes. TCP: sndrexmitpack Total number of retransmitted packets. TCP: sndrexmitbyte Total number of retransmitted bytes. TCP: rcvtotal Total number of received packets. TCP: rcvbyte Total number of received bytes. DLC: 16 collisions Number of collision incidents. A collision occurs when two or more instruments on the network attempt to transmit simultaneously. The tendency for collisions to occur increases when the network is congested. 16 collisions would mean 16 consecutive collision incidents. quit Disconnects the connection of the instrument being operated Syntax quit 4.10 Instrument Information Output Commands (Available when using the instrument information server function via Ethernet communications) The instrument information server function interprets one UDP packet to be one command and returns a single packet (containing the recorder’s information) in response to the command. Port number 34264/udp (see section 2.1) Transfer data ASCII Received buffer length 128 Transmit buffer length 512 Maximum number of parameters 32 In the command packet, parameters corresponding to the desired information are placed one after another. Parameter Description serial Outputs the serial number. host Outputs the host name (the host name specified in section 2.3). ip Outputs the IP address (the IP address specified in section 2.3). Example Query the IP address and host name. (Of the two frames below, the top frame represents the command packet, the bottom frame represents the response packet.) ip host EA ip = 192.168.111.24 host = ABC EN Description • Separate each parameter with one or more blanks (space, tab, carriage return, line feed). • Parameters are not case sensitive. • Undefined parameters are ignored. • Parameters beyond the 32nd parameter are ignored. 4.10 Instrument Information Output Commands (Available when using the instrument information server function via Ethernet communications)

The following table shows the types of responses for various commands described in the

previous chapter. The recorder returns a response (affirmative/negative response) to a command that is separated by a single terminator. The controller should follow the one command to one response format. Command Function See section 4.9. See section 4.10. Setting/Measurement server Maintenance/Test Server Instrument Information server Response Command Type Affirmation Negation Setting command Basic setting command Control command Output command RS-422A/485 dedicated Dedicated response No response Setup, measurement, and computation data output ASCII output BINARY output Affirmative response Single negative response or Multiple negative responses Note The “CRLF” used in this section denotes a terminator. Affirmative Response When the command is processed correctly, an affirmative response is returned. • Syntax E0CRLF • Example E0 Single Negative Response When the command is not processed correctly, a single negative response is returned. • Syntax E1_nnn_mmm•••mCRLF nnn Error number (001 to 999) mmm•••m Message (variable length, one line) _ Space • Example E1 001 "System error" Multiple Negative Responses • If there is an error in any one of the multiple commands that are separated by sub delimiters, multiple negative responses are returned. • The response is generated for each erroneous command. • If there are multiple commands that have errors, the negative responses are separated by commas. • The error position number is assigned to the series of commands in order starting with “1” assigned to the first command. • Syntax E2_ee:nnnCRLF (When there is only one error) E2_ee:nnn,ee:nnn,•••,ee:nnnCRLF (When there are multiple errors) ee Error position (01 to 10) nnn Error number (001 to 999) _ Space Chapter 5 Responses

The following types of ASCII data are available. For the data formats, see section 5.2.

Setting data, basic setting data, decimal position/unit information, measured/ computed data, report data generated by the periodic printout, status information, and user information • Syntax EACRLF •••••••••••••••CRLF : •••••••••••••••CRLF •••••••••••••••CRLF ENCRLF BINARY Output • Conceptual Diagram 'E' 'B' CR LF BINARY data ASCII BINARY Data length Data sum Flag ID Header sum 1 byte BINARY header (12 bytes) BINARY data BINARY footer (2 bytes) • EBCRLF Indicates that the data is BINARY. • Data Length The byte value of “flag + identifier + header sum + BINARY data + data sum.” • Header Sum The sum value of “data length + flag + identifier.” • BINARY Data For the output format of various data types, see section 5.3. • Data Sum The sum value of “BINARY data.” Note The data length of the BINARY header section is output according to the byte order specified with the BO command. 5.1 Response Syntax

Meaning of the Flag

0 1 7 BO MSB LSB Output byte order 6 CS No Yes Existence of a checksum 5 – – – 4 – – – 3 – – – 2 – – – 1 – – – 0 Reserved – – Fixed to 1. • When the BO flag is “0,” the MSB is output first. When the BO flag is “1,” the LSB is output first. • If the check sum is enabled (parameter = 1) using the CS command parameter, each sum value is inserted in the header sum and data sum sections in the “Conceptual Diagram” on the previous page. If the check sum is disabled (parameter = 0), a zero is inserted in the header sum and data sum sections. For a sample program that calculates the sum value, see “Calculating the Sum Value” on the next page. • The bits that have “–” for the flag and flag are not used. The value is undefined. • Identifier ID Number Binary Data Type Format 0 Undefined file – 1 Measured/computed data Section 5.3 1 FIFO data Section 5.3 10 Setup data file Undisclosed • The table above shows the different types of BINARY Data. • Measured/computed data can be output using the FD command. • FIFO data can be output using the FF command. • The setup data file can be output using the FE command. The setup data file can be loaded in the cofiguration software. • The identifier section in the “Conceptual diagram” on the previous page contains the ID number shown above. Note BINARY data that are not indicated in the above table are considered undefined files. • Calculating the Sum Value If you set the parameter of the CS command to “1 (enabled),” the checksum value is output only during serial communications. The check sum is the same as that used in the TCP/IP and is derived according to the following algorithm. Buffer on Which the Sum Value Is Calculated • For the header sum, it is calculated from “data length + flag + identifier” (fixed to 6 bytes). • For the data sum, it is calculated from “BINARY data.” 1 byte 0 (1) (2) (3) (4) (6) (5) Padding 5.1 Response Syntax

If the data length of the buffer is odd, a “0” is padded so that it is even. (1) through (6)

are summed as unsigned two-byte integers (unsigned short). If the digit overflows a “1” is added. Finally, the result is bit-wise inverted. Sample Program The sum value is determined using the following sample program, and the calculated result is returned. The sum determined by the sample program can be compared with the header sum of the output BINARY header section and the data sum of the output BINARY footer section. /* * Sum Calculation Function (for a 32-bit CPU) * * Parameters buff: Pointer to the top of the data on which the sum is calculated * len: Length of the data on which the sum is calculated * Return value: Calculated sum */ intcksum(unsigned char *buff, int len) { unsigned short *p; /* Pointer to the next two-byte data word in the buffer that is to be summed. */ unsigned int csum; /* Checksum value */ int i; int odd; csum = 0; /* Initialize. */ odd = len%2; /* Check whether or not the number of data points is even. */ len >>= 1; /* Determine the number of data points using a “short” data type. */ p = (unsigned short *)buff; for(i=0;i>16) & 0xffff)) > 0xffff) /* Add the overflowed digits */ csum = csum - 0xffff;/* If the digit overflows again, add a 1. */ return((~csum) & 0xffff); /* bit inversion */ } 5.1 Response Syntax

RS-422A/485 Dedicated Commands and Responses

The following table shows dedicated commands for the RS-422A/485 interface and their responses. Command Syntax Meaning Response ESC O_xx CRLF Open the instrument. • Response from the instrument with the specified address ESC O xx CRLF (_ space) • Response when the instrument with the specified address does not exist* ESC C_xx CRLF Close the instrument. • Response from the instrument with the specified address ESC C xx CRLF (_ space) • Response when the instrument with the specified address does not exist* * The causes that the condition become “The instrument with the specified address does not exist” is such as a command error, the address not matching that of the instrument, the instrument is not turned ON, and the instrument not being connected via the serial interface. • The “xx” in the table indicates the instrument’s address. Specify the address that is assigned to the instrument from 01 to 32. • Only one instrument can be opened at any one time. • When an instrument is opened with the ESC O command, all commands on the instrument become active. • When an instrument is opened with the ESC O command, any other instrument that is open is automatically closed. • Use CR+LF for the terminator. LF cannot be used. Note • The ASCII code of ESC is 1BH. 5.1 Response Syntax

Output Format of ASCII Data

The following types of ASCII data are available. • Setting data/Basic Setting data • Decimal point position/unit information • Measured/computed data • Report data generated by the periodic printout • Status information • User information Note The “CRLF” used in this section denotes a terminator. Setting/Basic Setting data • The FE command (FE0 or FE2) is used to output the data. • The setting/basic setting data are output in the order of the listed commands in the table in section 4.2, “A List of Commands.” However, the setting information for the following commands is not output. • Setting commands SD, CM, and FR • Basic Setting commands YE and XE • The output format of the setting/basic setting data is the same as the syntax of each command. • Some commands are output in multiple lines. (Example: Commands that are specified for each channel.) • Syntax The two-character command name and the succeeding parameters are output in the following syntax. EACRLF ttsss•••sCRLF •••••••••••••• ENCRLF tt Command name (SR, SA•••, XA, XI•••) sss•••s Setting, basic setting data (variable length, one line) • Example EA SR01,VOLT,20mV,0,20 SR02,VOLT,20mV,0,20 ••••••••••••••••••• EN

Decimal Point Position/Unit Information

• The FE command (FE1) is used to output the data. • Syntax The data is output for each channel in the following syntax. EACRLF s_kccuuuuuu,ppCRLF •••••••••••••••••• ENCRLF s Data status (N, D, S) N: Normal D: Differential input S: Skip (When the input range is set to SKIP for a measurement channel or when the channel is turned OFF for a computation channel) k Channel type 0: Measurement channel A: Computation channel cc Channel number RD100B: 01 to 06, 0A to 0P RD1800B: 01 to 24, 0A to 1P uuuuuu Unit information (6 characters, left-justified) mV____: mV V_____: V ^C____: °C xxxxxx: (User-defined character string) pp Decimal point position (00 to 04) No decimal (00000) for 00. One digit to the right of the decimal (0000.0) for 01. Two digits to the right of the decimal (000.00) for 02. Three digits to the right of the decimal (00.000) for 03. Four digits to the right of the decimal (0.0000) for 04. _ Space • Example EA N 001mV ,01 N 002mV ,01 EN 5.2 Output Format of ASCII Data

The FD (FD0) or FY (FYInst, FYTlog1, or FYTlog2) command is used to output the

data. • Syntax The measured/computed data are output in the following syntax along with the date and time information for each channel EACRLF DATE_yy/mo/ddCRLF TIME_hh:mi:ss.mmmt_S1S2S3S4S5S6CRLF s_kcca1a2a3a4uuuuuuf1dddddEf2ppCRLF •••••••••••••••••••••••••••• ENCRLF yy Year (00 to 99) mo Month (01 to 12) dd Day (01 to 31) hh Hour (00 to 23) mi Minute (00 to 59) ss Second (00 to 59) mmm Millisecond (000 to 999. A period is placed between seconds and milliseconds.) t ‘S’(=summer) or ‘ ’ space(=winter) S1S2S3S4S5S6 Data status Takes on the values below for the FYTlog1 and FYTlog2 commands. For all other cases, they are all spaces. S1 Time change during TLOG computation: T (occurred) or space (not occurred) S2 Power OFF and ON during TLOG computation: P (occurred) or space (not occurred) S3 Data reset during the TLOG computation: R (occurred) or space (not occurred) S4S5S6 All spaces s Channel data status (N, D, S, O, B, E) N: Normal D: Differential input S: Skip O: Over B: Burnout E: Error k Channel type 0: Measurement channel A: Computation channel cc Channel number RD100B: 01 to 06, 0A to 0P RD1800B: 01 to 24, 0A to 1P a1a2a3a4 a1 Alarm status (level 1) a2 Alarm status (level 2) a3 Alarm status (level 3) a4 Alarm status (level 4) 5.2 Output Format of ASCII Data

Each status is set to H, L, h, l, R, r, T, t, or space.

H: high limit alarm, L: low limit alarm, h: difference high-limit alarm, l: difference low-limit alarm, R: high limit on rate-of- change alarm, r: low limit on rate-of-change alarm, T: delay high limit alarm, t: delay low limit alarm, space: no alarm uuuuuu Unit information (6 characters, left-justified) mV____: mV V_____: V ^C____: °C xxxxxx: (User-defined character string) f1 Sign (+, –) of mantissa • Positive over data, error data, and the burnout data when “up” is specified are positive. • Negative over data and the burnout data when “down” is specified are negaitive. ddddd Mantissa (00000 to 99999, 5 digits) • 8 digits for computed data. • For error data (channel data status is E), over data (channel data status is O), or burnout data (channel status data is B), the mantissa is set to 99999 (99999999 for computed data). f2 Sign (+, –) of exponent pp Exponent (00 to 04) _ Space • Example EA DATE 99/02/23 TIME 19:56:32.500 N 001h mV +12345E-03 N 002 mV -12345E-01 S 003 EN Note • Data for non-existing channels are not output (not even the channel number). • For channels set to skip, output values from alarm status to exponent are spaces. 5.2 Output Format of ASCII Data

Report Data Generated by the Periodic Printout

• The FY command (FYREPORT) is used to output the data. • Report data generated by the periodic printout is output. Syntax EACRLF YY/MO/DD_HH:MI:SS.MMMTCRLF yy/mo/dd_hh:mi:ss.mmmt_S1S2S3S4S5S6CRLF s1s2s3s4s5s6kccuuuuuuf1dddddEf2pp_f1dddddEf2pp_f1dddddEf2pp_f1ddddd Ef2pp_f1ddddddddEf2ppCRLF •••••••••••••••••• ENCRLF YY/MO/DD HH:MI:SS.MMMT Report start time information yy/mo/dd hh:mi:ss.mmmt Report end time information YY, yy Year (00 to 99) MO, mo Month (01 to 12) DD, dd Day (01 to 31) HH, hh Hour (00 to 23) MI, mi Minute (00 to 59) SS, ss Second (00 to 59) MMM, mmm Millisecond (000 to 999) T, t ‘S’(=summer) or ‘ ’ space(=winter) S1S2S3S4S5S6 Data status S1 Time change during reporting: T (occurred) or space (not occurred) S2 Power OFF and ON during reporting: P (occurred) or space (not occurred) S3 Data clear during reporting: R (occurred) or space (not occurred) S4S5S6 All spaces s1s2s3s4s5s6 Channel data status s1 Channel mode at the end of reporting: S (Skipped) or space (Mode other than skipped) s2 Range change during reporting: C (occurred) or space (not occurred) s3 Error data occurrence during reporting: E (yes) or space (no) s4 ±over data occurrence during reporting: O (yes) or space (no) s5s6 All spaces cc Channel number RD100B: 01 to 06, 0A to 0P RD1800B: 01 to 24, 0A to 1P k Channel type (0, A) 0: Measurement channel A: Computation channel uuuuuu Unit information (6 characters) 5.2 Output Format of ASCII Data

The data is output in the following order: most recent value,

minimum value, maximum value, average value, and sum value. f1dddddEf2pp Most recent value, minimum value, maximum value, and average value of the measurement channel f1ddddddddEf2pp Sum value of the measurement channel or the most recent value, minimum value, maximum value, average value, and sum value of the computation channel f1 Sign (+, –) of mantissa ddddd Mantissa (00000 to 99999) dddddddd Mantissa (00000000 to 99999999) f2 Sign (+, –) of exponent pp Exponent (00 to 04) • Example EA 04/08/04 10:22:20.500S 04/08/04 19:56:32.500S TP 001mV +12345E-03 +12345E-03 +12345E-03 +12345E-03 +12345678E-03 C 002mV -12345E-01 -12345E-01 -12345E-01 -12345E-01 -12345678E-01 S 003 S 004 A0A +12345678E-03 +12345678E-03 +12345678E-03 +12345678E-03 +12345678E-03 A0B -12345678E-01 -12345678E-01 -12345678E-01 -12345678E-01 - 12345678E-01 S A0C S A0D EN 5.2 Output Format of ASCII Data

The IS command is used to output the data.

• The operation status of the recorder is output • For details on the status information, see section 6.2, “The Bit Structure of the Status Information.” • Syntax EACRLF ddd.ccc.bbb.aaaCRLF ENCRLF aaa Status information 1 (000 to 255) bbb Status information 2 (000 to 255) ccc Status information 3 (000 to 255) ddd Status information 4 (000 to 255) • Example EA 000.000.032.000 EN User Information • The FU command is used to output the data. • User name, user level, and other information are output. • Syntax EACRLF p_l_uuu•••uCRLF ENCRLF p Physical layer E: Ethernet S: RS-422A/485 l User level A: Administrator U: User uuu•••u User name (up to 16 characters) _ Space • Example EA E A admin EN 5.2 Output Format of ASCII Data

Output Format of BINARY Data

This section describes the output format of the BINARY data that is disclosed. For the BINARY output format, see “BINARY Output” on page 5-2. For other BINARY data types, see “Identifier” on page 5-3. The measured data is output using signed 16-bit integer; the computed data is output using signed 32-bit integer. These integers can be understood as physical values by adding the decimal point and the unit. Typical Examples to Obtain Physical Values BINARY Value Decimal Position Code Physical Value (Measured Value) 10000 0 10000 10000 1 1000.0 10000 2 100.00 10000 3 10.000 10000 4 1.0000 Measured/Computed Data and FIFO Data • The FD (FD1) command is used to output the most recent measured/computed data. • The FF (FEGET, FERESEND, and FEGETNEW) command is used to output the FIFO data. The decimal point position and unit can be determined using the FE command. • The ID number of the output format is 1. See “Identifier” on page 5-3. 2 bytes Number of bytes 2 bytes BINARY data (The BINARY data section on the “Conceptual diagram” on page 5-2.) Number of blocks Block 1 Block n ... • Number of Blocks This is the number of blocks. • Number of Bytes This is the size of one block in bytes. • Block Year Measured/ Computed ... ... Measured/ Computed ... ... Month Channel ... ... Channel ... ... Day A2A1 ... ... A2A1 ... ... Hour A4A3 ... ... A4A3 ... ... Minute Millisecond (Reserved)* Flag Second Measured data ... ... Computed data ... ... 1 byte 1 byte 1 byte 1 byte 1 byte 1 byte 2 bytes 1 byte 1 byte 4 bytes * The sections indicated as (Reserved) are not used. The value is undefined.

The meanings of the flags are given on the table below. The flags are valid during

FIFO data output. The flags are undefined for other cases. Bit Flag Flag Meaning of the Flag 0 1 6 – – 5 – – 4 – – 3 – – 2 No Yes Indicates that the decimal position or unit information was changed during measurement. 1 No Yes Indicates that the FIFO acquiring interval was changed during measurement. 0 No Yes Indicates that the internal process took too much time (computation, for example) and that FIFO dropout occurred. The bits that have “–” for the flag column are not used. The value is undefined. • Block Member Name BINARY Value Year 0 to 99 Month 1 to 12 Day 1 to 31 Hour 0 to 23 Minute 0 to 59 Second 0 to 59 Millisecond 0 to 999 DST 1 (=summer) or 0 (=winter) Measurement, computation 00H: measurement, 80H: computation Channel RD100B: 01 to 06 and 31 to 42 RD1800B: 01 to 24, 31 to 54 Alarm status* A1 (Bit 0 to 3) A2 (Bit 4 to 7) 0 to 8 A3 (Bit 0 to 3) A4 (Bit 4 to 7) Measured data 0 to FFFFH Computed data 0 to FFFFFFFFH * BINARY value 0 to 8 is entered in the upper and lower 4 bits of a byte (8 bits) for the alarm status. The binary values 0 to 8 correspond to H (high limit alarm), L (low limit alarm), h (difference high-limit alarm), l (difference low-limit alarm), R (high limit on rate-of-change alarm), r (low limit on rate-of-change alarm), T (delay high limit alarm), and t (delay low limit alarm) as follows: 0: no alarm, 1: H, 2: L, 3: h, 4: l, 5: R, 6: r, 7: T, and 8: t. • Special Data Value The measured/computed data take on the following values under special conditions. Special Data Value Measured Data Computed Data + Over 7FFFH 7FFF7FFFH – Over 8001H 80018001H Skip 8002H 80028002H Burnout (when “up” is set) 7FFAH 7FFF7FFFH Burnout (when “down” is set) 8006H 80018001H Error 8004H 80048004H Undefined 8005H 80058005H Note The number of blocks, number of bytes, and measured/computed data are output according to the byte order specified with the BO command. 5.3 Output Format of BINARY Data

Status Information and Filter

The following figure illustrates the status information and filter on the recorder. Status information Filter Condition register 4 bytes 4 3 2 1 4 3 2 1 • When a status indicated on the following page is entered, the corresponding bit in the condition register is set to “1.” The logical AND of the condition register and the filter becomes the status information. • The IF command can be used to set the filter. • The IS command is used to output the status information. Status information 1 and 2 are cleared when they are output. Status information 3 and 4 are not cleared when it is output, and remains at “1” while the event is occurring. • When multiple connections are up, filters can be specified for the individual connection. Therefore, the status information can be held for each connection. Chapter 6 Status Information

The Bit Structure of the Status Information

The following four groups of status information are output in response to a status information output request using the IS command. For the output format, see “Status Information” in section 5.2, “Output Format of ASCII Data.” Status Information 1 Bit Name Description 0 A/D conversion complete Set to “1” when the A/D conversion of the measurement is complete. 1 – – 2 Periodic printout timeout Set to “1” when the periodic printout timer expires. 3 TLOG timeout Set to “1” when the TLOG timer expires. 4 – – 5 – – 6 – – 7 – – Status Information 2 Bit Name Description 0 Measurement drop Set to “1” when the measurement process could not keep up. 1 Decimal point/unit Set to “1” when the decimal point/unit information is information change changed. 2 Command error Set to “1” when there is a command syntax error. 3 Execution error Set to “1” when an error occurs during command execution. 4 – – 5 – – 6 – – 7 – – Status Information 3 Bit Name Description 0 – – 1 Chart end Set to “1” while the recorder is out of chart paper. 2 – – 3 – – 4 – – 5 Chart feeding Set to “1” while the chart is being fed through the panel key. 6 – – 7 – – Status Information 4 Bit Name Description 0 Basic setting Set to “1” during Basic Setting mode. 1 Recording Set to “1” while recording is in progress. 2 Computing Set to “1” while computation is in progress. 3 Alarm generating Set to “1” while the alarm is occurring. 4 – – 5 – – 6 – – 7 – –

ASCII Character Codes

The table below contains the ASCII character codes of characters that can be used. The table below shows characters each command can use. Command Used for Characters SN Unit Alphanumeric characters, signs, and space ST Tag Alphanumeric characters, signs, and space SG Message Alphanumeric characters, signs, and space YB Host/Domain name Alphanumeric characters and signs YN Domain suffix Alphanumeric characters and signs SO Computing equation Alphanumeric characters, signs, and space Note “µ”, “Ω”, “2”, “3” , and ”°” are assigned to character codes as follows: µ: 7BH ({), Ω: 7CH (|), 2: 7DH (}), 3: 7EH (~) , °: 5EH (^) Characters in the parentheses are characters assigned on a keyboard. 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 LF CR 1 ESC 2 SP # % ( ) * + – . / 3 0 1 2 3 4 5 6 7 8 9 4 @ A B C D E F G H I J K L M N O 5 P Q R S T U V W X Y Z ° 6 a b c d e f g h i j k l m n o 7 p q r s t u v w x y z µ Ω 2 3 8 9 A B C D E F Upper 4 bits Lower 4 bits (space) Appendix

Output Flow of FIFO Data

The recorder has a dedicated internal memory for outputting measured/computed data. This memory is structured as a FIFO (First-In-First-Out). Measured/computed data are constantly acquired to the internal memory at the specified acquiring interval (FIFO acquiring interval, set with the FR command). By using this function, it is possible to read measured/computed data that have been saved at the specified intervals regardless of the frequency at which the PC periodically reads the measured/computed data. The following example shows the case when the acquiring interval is 1 s and the buffer capacity is for 8 intervals. Most recent acquire Position: WP Previous read Position: RP1 Current read Position: RP2 Block 1 2 3 4 5 6 7 Block 8 • Acquiring of the measured/computed data • The measured/computed data are acquired to the internal memory at 1 s intervals. • Measured/computed data are acquired to blocks 1 through 8 in order. After acquiring to block 8, the next acquiring operation returns to block 1. • Reading the measured/computed data (FF GET command is used, logging output) Outputs the data from the next to the previous read position (RP1) to the most recent acquire position (WP). In this example, more than 2 s has elapsed from the previous read operation. Therefore, data in blocks 5 and 6 are output. • Reading the measured/computed data (FF GETNEW command is used, output of the most recent value) Output the specified number of blocks of FIFO data back starting from the recent acquire position (WP). In this example, if you specify the number of blocks to “5,” data in blocks 2 to 6 are output. The buffer capacity varies depending on the model. Pen model: 240 intervals (30 s at an acquiring interval of 125 ms) Dot model: 60 intervals (60 s at an acquiring interval of 1 s)

Example in which the FIFO acquiring interval on the recorder is set to 1 s and the

measured data from channel 01 to 06 are continuously output (logging function) BINARY header BINARY data BINARY footer FF RESET YES NO END Send command Stop measurement? Receive response E0 Send command Receive response Wait for the FIFO acquiring interval (1 s) Move the FIFO read position to the most recent acquire position. Command description Command to send Received response data Output the measured/computed data using the FIFO. START BINARY (see page 5-2 and 5-13) FF GET,01,06 Note • The FIFO acquiring interval must be set using the FR command beforehand. • The FIFO acquiring interval applies to both serial and Ethernet communications. Appendix 2 Output Flow of FIFO Data

When using the Setting/Measurement server or the Maintenance/Test server via the

Ethernet interface (/C7 option), you must log into the recorder from the PC. If you complete the procedure successfully up to login complete in the following figure, the commands in chapter 4 become functional. When using the login function E1 403 E1 403 Yes No No No No No No E1 404 E1 421 Connect Disconnect E1 422 Disconnect E1 420 Disconnect Login complete Within 3 retries?†† Within 3 retries?†† Wait 5 s E1 401 E0 E1 400 Entered "quit"? Verification match? Within the number of simultaneous uses?††† Within 2 minutes? Within the number of connections† Within 2 minutes? User name Password Increment retry count 1 1 1 1 End Start Judgment Transition Code (for a description of codes and messages, see page App-6) Response from the µR (message omitted) For a description of the response format, see section 5.1. User entry † Connections cannot exceed the maximum number of connections (see section 2.1). †† If you attempt to log in using a wrong password four consecutive times, the communication is dropped (the number of retries for login is three). ††† If you attempt to log in causing the number of simultaneous uses at the administrator or user level to be exceeded (see section 2.1) four consecutive times, the communication is dropped (even if the password is correct).

When not using the login function

Login as “admin” or “user.” • The user name “admin” can be used to login to the recorder as an administrator. • The user name “user” can be used to access the recorder as a user. E1 403 Yes No No No No No No E1 404 E1 421 Connect Disconnect E1 422 Disconnect E1 420 Disconnect Login complete Within 3 retries? Within 3 retries? E0 E1 402 Entered "quit"? Verification match? Within the number of simultaneous uses? Within the number of connections? Within 2 minutes? User name Increment retry count 1 1 1 1 Appendix 3 Login Procedure

A List of Error Messages

There are cases in which error codes and messages are displayed on the screen during operation. The error messages and their description are listed below. Setting Errors Code Message Explanation/Countermeasures 1 System error. Contact OMEGA. 2 Incorrect date or time setting. Check the setting. 3 A disabled channel is selected. The channel does not exist. 4 Incorrect function parameter. Incorrect communication parameter. 5 The input numerical value exceeds the set range. – 6 Incorrect input character string. The entered character cannot be used. 7 Too many characters. – 8 Incorrect input mode. Incorrect range mode (Volt, TC, Scale, etc.) setting. 9 Incorrect input range code. Incorrect range type (2 V, R, PT100, etc.) setting. 10 Format error. Incorrect character string format. 11 Range settings are not same within the selected Channels whose range differs cannot be set simultaneously. channels. 12 An invalid characters. Contains an invalid character. 13 Ref. CH error. Specify a channel whose range is set to voltage, TC, or RTD for the reference channel. 21 Cannot set an alarm for a SKIPPED channel. – 22 The upper and lower span limits are equal. This is not allowed. 23 The upper and lower scale limits are equal. This is not allowed. 24 The lower span limit is greater than the upper span – limit. 25 The lower scale limit is greater than the upper scale – limit. 26 Bias cannot be set to the SKIPPED channel. – 27 Bias cannot be set to the DI channel. – 30 The partial boundary value exceeds the range of the – span. 31 Partial is invalid on the SKIPPED channel. – 35 The upper and lower limits of the printing zone Set the rightmost value of the zone – the leftmost value ≥ 5 are equal. mm. 36 The lower limit of the printing zone is greater Set the rightmost value of the zone – the leftmost value ≥ 5 than the upper limit. mm. 37 The printing zone is narrower than the minimum Set the rightmost value of the zone – the leftmost value ≥ 5 width (5 mm). mm. 38 Partial is invalid on the DI channel. – 47 All items in DISP menu parameters are set to SKIP. – 48 Start = Finish. The DST start time and end time cannot be set to the same time. 49 Invalid or missing DST time settings. Since the time gains one hour when the DST starts, the set-up time does not exist. 61 There is no channel specified by the MATH Set a computation channel. expression. 62 MATH expression grammar is incorrect. Enter the equation correctly. 63 MATH expression sequence is incorrect. Enter the equation correctly. 64 MATH upper and lower span values are equal. This is not allowed. 70 MATH constant description is incorrect. Incorrect computation constant syntax. 71 The range of the MATH constant is exceeded. – 72 MATH channel is turned off –

Appendix 4 A List of Error Messages

Code Message Explanation/Countermeasures 81 All space or ‘quit’ string cannot be specified. – 86 The key-lock release password is incorrect. Enter the correct password. 87 This key is locked. – 91 Password is incorrect. Enter the correct password. 100 IP address doesn’t belong to class A, B, or C. – 101 The result of the masked IP address is all 0s or 1s. – 102 SUBNET mask is incorrect. Set a correct subnet mask. 103 The net part of default gateway is not equal to Set the correct default gateway. that of IP address. 151 This action is invalid during calculation. – 160 This action is invalid during chart end. – 161 This action is invalid during pen hold. – 162 Cannot set an number for a skipped data. – 163 This action is invalid during record. – 164 This action is invalid during manual printing. – 165 This action is invalid during list printing. – 166 This action is invalid during setup list printing. – 167 This action is invalid during chart feed. – 169 This action is invalid during ribbon hold. – Operation Errors Code Message Explanation/Countermeasures 232 There is no available data. There is no data for periodic printout or data for calculating TLOG when the timer expired. Communication Errors The messages from 390 to 422 can only be returned via communication, and are not displayed on the recorder. Code Message Explanation/Countermeasures 300 Command is too long. – 301 Too many number of commands delimited with ’;’. Keep the number of commands separated by sub delimiters under 10. 302 This command has not been defined. – 303 Data request command can not be enumerated with – sub-delimiter. 350 Command is not permitted to the current user level. – 351 This command cannot be specified in the current – mode. 352 The option is not installed. – 353 This command cannot be specified in the current – setting. 354 This command is not available during calculation. – 390 Command error. – 391 Delimiter error. – 392 Parameter error. – 393 No permission. – 394 No such connection. – 395 Use “quit” to close this connection. Attempted to disconnect its own connection. 396 Failed to disconnect. – 397 No TCP control block. The control block of the specified connection cannot be found.

Appendix 4 A List of Error Messages

Code Message Explanation/Countermeasures 400 Input username. – 401 Input password. – 402 Select username from ‘admin’ or ‘user’. If the recorder is configured not to use the user name and password, use user names ‘admin’ or ‘user’. 403 Login incorrect, try again! – 404 No more login at the specified level is acceptable. – 420 Connection has been lost. – 421 The number of simultaneous connection has been – exceeded. 422 Communication has timed-out. – Warning Messages Code Message Explanation/Countermeasures 600 Initialized. Settings and measured data have been initialized. System Errors Code Message Explanation/Countermeasures 902 RAM failure. Contact OMEGA. 910 A/D error. Contact OMEGA. 921 A/D calibration value error. Contact OMEGA. 922 A/D calibration is in the wrong order. Contact OMEGA. 930 Memory acquisition failure. Contact OMEGA. 940 The ethernet module is down. Contact OMEGA. 950 A/D number error. Contact OMEGA. 951 EEPROM write error. Contact OMEGA. 960 Ribbon error Contact OMEGA. 961 Printer error Contact OMEGA. 962 Plotter error Contact OMEGA. 963 Pen 1 error Contact OMEGA. 964 Pen 2 error Contact OMEGA. 965 Pen 3 error Contact OMEGA. 966 Pen 4 error Contact OMEGA.

host ............................................................................. 4-30

IF ................................................................................ 4-26 ip ................................................................................. 4-30 IS ................................................................................ 4-28 LS ............................................................................... 4-25 MC .............................................................................. 4-26 MP .............................................................................. 4-25 MS .............................................................................. 4-25 net ............................................................................... 4-29 PS ............................................................................... 4-25 quit .............................................................................. 4-30 SA ............................................................................... 4-11 SC ............................................................................... 4-12 SD ............................................................................... 4-13 SE ............................................................................... 4-14 serial ........................................................................... 4-30 SF ............................................................................... 4-14 SG .............................................................................. 4-14 SJ ............................................................................... 4-15 SK ............................................................................... 4-15 SN ............................................................................... 4-12 SO .............................................................................. 4-11 SP ............................................................................... 4-13 SR ............................................................................... 4-10 SS ............................................................................... 4-15 ST ............................................................................... 4-14 SU ............................................................................... 4-25 SV ............................................................................... 4-14 SZ ............................................................................... 4-13 TD ............................................................................... 4-14 TL ............................................................................... 4-25 UA ............................................................................... 4-23 UB ............................................................................... 4-20 UC .............................................................................. 4-19 UD .............................................................................. 4-25 UF ............................................................................... 4-21 UI ................................................................................ 4-20 UJ ............................................................................... 4-20 UK ............................................................................... 4-20 UL ............................................................................... 4-20 UM .............................................................................. 4-20 UN .............................................................................. 4-22 UO .............................................................................. 4-19 UP ............................................................................... 4-19 UR .............................................................................. 4-19 US ............................................................................... 4-22 UT ............................................................................... 4-21 UY ............................................................................... 4-26 VB ............................................................................... 4-11 VD ............................................................................... 4-16 VF ............................................................................... 4-14 VG .............................................................................. 4-26 VR ............................................................................... 4-13 VT ............................................................................... 4-13 XA ............................................................................... 4-18 XB ............................................................................... 4-19 XE ............................................................................... 4-24 XI ................................................................................ 4-18 XJ ............................................................................... 4-19 XN ............................................................................... 4-20 XQ .............................................................................. 4-22 XR ............................................................................... 4-21 YA ............................................................................... 4-22 YB ............................................................................... 4-22 Symbols Page 1-5V input low-cut ............................................................. 4-21 A Page A/D integral time ............................................................... 4-18 address ............................................................................. 3-12 administrator ....................................................................... 2-9 affirmative response ............................................................ 5-1 alarm .......................................................................4-11, 4-18 alarm ACK ......................................................................... 4-25 alarm acknowledge ........................................................... 4-25 alarm delay ....................................................................... 4-21 alarm delay time ................................................................ 4-14 alarm printout buffer .......................................................... 4-25 ASCII character codes ................................................... App-1 ASCII data ........................................................................... 5-6 ASCII output ........................................................................ 5-2 assignment of channels .................................................... 4-22 B Page bar graph ........................................................................... 4-20 basic setting commands ..................................................... 4-4 basic setting mode ........................................................ vi, 4-3 baud rate ........................................................................... 3-12 bias .........................................................................4-11, 4-21 BINARY data ..................................................................... 5-13 BINARY output .................................................................... 5-2 bit structure ......................................................................... 3-7 brightness ......................................................................... 4-14 burnout detection .............................................................. 4-19 byte output order ............................................................... 4-26 C Page channel number .................................................................. 4-8 chart speed ............................................................... 4-9, 4-12 checksum .......................................................................... 4-26 checksum value .................................................................. 5-3 closes the instrument ........................................................ 4-28 command AC ............................................................................... 4-25 AK ............................................................................... 4-25 BD ............................................................................... 4-14 BO .............................................................................. 4-26 CC .............................................................................. 4-26 close ........................................................................... 4-29 CM .............................................................................. 4-15 con .............................................................................. 4-29 CS ............................................................................... 4-26 DS ............................................................................... 4-25 ESC C ......................................................................... 4-28 ESC O ........................................................................ 4-28 eth ............................................................................... 4-29 FD ............................................................................... 4-27 FE ............................................................................... 4-27 FF ............................................................................... 4-27 FR ............................................................................... 4-15 FU ............................................................................... 4-28 FY ............................................................................... 4-27 help ............................................................................. 4-29

YC ............................................................................... 4-26

YD ............................................................................... 4-23 YE ............................................................................... 4-24 YK ............................................................................... 4-23 YN ............................................................................... 4-23 YQ .............................................................................. 4-23 YS ............................................................................... 4-21 command syntax ................................................................. 4-1 command-response rule ..................................................... 4-2 communication input data ......................................... 4-8, 4-15 computation error .............................................................. 4-22 computing equation ........................................................... 4-11 connection (ethernet) .......................................................... 2-2 connection (RS-422A/485) .................................................. 3-2 connection example (RS-422A/485) ................................... 3-3 connection information ...................................................... 4-29 connection status of the Ethernet interface ......................... 2-7 constant .................................................................... 4-8, 4-15 control commands ............................................................... 4-5 conventions ........................................................................... iv converter ............................................................................. 3-5 copying & pasting a character string .....................................vii D Page data display screen ........................................................... 4-16 data length ........................................................................ 3-12 date and time .................................................................... 4-13 decimal point position ....................................................... 4-27 decimal point position output .............................................. 5-7 default gateway ................................................................... 2-6 deleting a character ............................................................. vii deleting an entire character string .........................................vii delimiter .............................................................................. 4-2 disconnects an Ethernet connection ................................. 4-26 disconnects the connection ..................................... 4-29, 4-30 display .................................................................................... v DNS .......................................................................... 2-6, 4-23 DNS server ......................................................................... 2-6 domain name ............................................................ 2-5, 4-22 domain suffix ....................................................................... 2-6 dot color ............................................................................ 4-19 dot printing interval ............................................................ 4-13 DST ......................................................................... 4-14, 4-15 E Page entering basic setting mode .................................................. vi entering characters .............................................................. vii entering values ......................................................................vii error messages .............................................................. App-6 ESC key ................................................................................ vi Ethernet interface ................................................................ 2-1 Ethernet statistical information .......................................... 4-29 execution mode ................................................................. 4-25 execution modes ........................................................... vi, 4-3 exiting from basic setting mode ........................................... viii exits from basic setting mode ........................................... 4-24 extended functions ............................................................ 4-21 F Page FIFO ............................................................................... App-2 FIFO data ................................................................ 4-27, 5-13 filter (status information) ..................................................... 6-1 first-in-first-out ................................................................ App-2 flag ............................................................................ 5-3, 5-14 frequently used parameters ................................................ 4-7 functional construction (ethernet) ........................................ 1-1 functional construction (RS-422A/485) ............................... 1-4 H Page help ................................................................................... 4-29 Hold register ...................................................................... 3-10 host name ....................................................... 2-5, 4-22, 4-30 I Page identifier .............................................................................. 5-3 indicator .............................................................................. 2-7 initializes settings .............................................................. 4-26 input filte ............................................................................ 4-14 input filter .......................................................................... 4-20 input range ................................................................ 4-7, 4-10 Input register ....................................................................... 3-9 inserting characters .............................................................. vii instrument information output commands ........................... 4-6 instrument information server ............................................. 1-2 interval for acquiring data to the FIFO buffer .................... 4-15 IP address ....................................................... 2-5, 4-22, 4-30 items to be printed ............................................................ 4-19 K Page keepalive ......................................................... 1-3, 2-12, 4-23 key operations ....................................................................... vi keys ........................................................................................ v L Page language ........................................................................... 4-20 list (setting information) printout ........................................ 4-25 log into the recorder ....................................................... App-4 login function ..................................................... 1-3, 2-9, 4-23 M Page maintenance/test commands .............................................. 4-6 maintenance/test server ...................................................... 1-2 manual print ...................................................................... 4-25 maximum number of simultaneous connections ................. 2-1 measured/computed data ................................................. 4-27 measured/computed data output ........................................ 5-8 message ................................................................. 4-14, 4-25 message printout buffer .................................................... 4-26 Modbus ....................................................................... 1-4, 3-8 moving average ...................................................... 4-14, 4-20 multiple negative responses ............................................... 5-1 N Page negative response ............................................................... 5-1 network statistical information ........................................... 4-29 O Page opens the instrument ........................................................ 4-28 operation mode ..................................................................... vi output commands ............................................................... 4-5 Index

parameters .......................................................................... 4-1

parity check ....................................................................... 3-12 partial expanded recording ..................................... 4-13, 4-20 password ............................................................................. 2-9 pen offset compensation ................................................... 4-19 periodic printout interval .................................................... 4-19 port number ......................................................................... 2-1 protocol ............................................................................... 2-1 Q Page query ................................................................................... 4-2 R Page rear panel ............................................................................... v receive buffer ...................................................................... 3-7 record position .................................................................. 4-23 recording on/off ................................................................. 4-13 relay number ....................................................................... 4-8 remote control input .......................................................... 4-21 remote control input terminal .............................................. 4-8 report data ............................................................... 4-20, 4-26 report data output .............................................................. 5-10 response ............................................................................. 4-2 revisions .................................................................................. i RJC ................................................................................... 4-19 RS-422A/485 communication interface .............................. 3-1 RS-422A/485 dedicated commands ................................... 4-5 RS-422A/485 dedicated commands and responses ........... 5-5 RS-422A/485 interface ...................................................... 4-21 run mode ....................................................................... vi, 4-3 S Page secondary chart speed ...................................................... 4-14 selecting the setup item and value ........................................ vi serial number .................................................................... 4-30 setting commands ............................................................... 4-3 setting mode ......................................................................... vi setting/basic setting data output ......................................... 5-6 setting/measurement server (ethernet) ............................... 1-1 setting/measurement server (RS-422A/485) ...................... 1-4 setup data ......................................................................... 4-27 setup list (basic setting information) printout ..................... 4-25 simultaneous users ............................................................. 2-1 special data value ............................................................. 5-14 square root low-cut ........................................................... 4-21 start bit ................................................................................ 3-7 starts/stops recording ........................................................ 4-25 starts/stops/resets computation ........................................ 4-25 statistical computation results ........................................... 4-27 status filter ......................................................................... 4-26 status information ...................................................... 4-28, 6-1 status information (bit structure) ......................................... 6-2 status information output ................................................... 5-12 stop bit ................................................................................ 3-7 stops the record position adjustment ................................ 4-26 sub delimiter ........................................................................ 4-2 subnet mask ........................................................................ 2-5 sum value ............................................................................ 5-4 switches the channel ......................................................... 4-25 switches the screen .......................................................... 4-25 syntax .................................................................................. 4-1 T Page tag ..................................................................................... 4-14 temperature unit ................................................................ 4-21 terminator .................................................................... 3-6, 4-2 time printout format ........................................................... 4-21 timeout ...................................................................... 1-3, 4-23 timeout time ...................................................................... 2-12 timer .................................................................................. 4-15 TLOG timer ....................................................................... 4-22 types of responses .............................................................. 5-1 U Page unit .................................................................................... 4-12 unit information ................................................................. 4-27 unit information output ........................................................ 5-7 user ..................................................................................... 2-9 user information ................................................................ 4-28 user information output ..................................................... 5-12 user level ..................................................................... 2-9, 4-3 user name ........................................................................... 2-9 Z Page zone recording .................................................................. 4-13

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a

period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, includ- ing but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner. RETURN REQUESTS/INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the prod- uct was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. Purchase Order number to cover the COST of the repair, 2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product. OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2005 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, repro- duced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.

Where Do I Find Everything I Need for

Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE �� Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies �� Wire: Thermocouple, RTD & Thermistor �� Calibrators & Ice Point References �� Recorders, Controllers & Process Monitors �� Infrared Pyrometers PRESSURE, STRAIN AND FORCE �� Transducers & Strain Gages �� Load Cells & Pressure Gages �� Displacement Transducers �� Instrumentation & Accessories FLOW/LEVEL �� Rotameters, Gas Mass Flowmeters & Flow Computers �� Air Velocity Indicators �� Turbine/Paddlewheel Systems �� Totalizers & Batch Controllers pH/CONDUCTIVITY �� pH Electrodes, Testers & Accessories �� Benchtop/Laboratory Meters �� Controllers, Calibrators, Simulators & Pumps �� Industrial pH & Conductivity Equipment DATA ACQUISITION �� Data Acquisition & Engineering Software �� Communications-Based Acquisition Systems �� Plug-in Cards for Apple, IBM & Compatibles �� Datalogging Systems �� Recorders, Printers & Plotters HEATERS �� Heating Cable �� Cartridge & Strip Heaters �� Immersion & Band Heaters �� Flexible Heaters �� Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL �� Metering & Control Instrumentation �� Refractometers �� Pumps & Tubing �� Air, Soil & Water Monitors �� Industrial Water & Wastewater Treatment �� pH, Conductivity & Dissolved Oxygen Instruments

Other Recording Equipment Manuals