Omron E3X-MDA Datasheet

Specifications

Brand: Omron
Category: Amplifier
Model: E3X-MDA (Datasheet)
File Type: PDF
File Size: —
Pages: 32

Read Online

Read the Omron E3X-MDA Datasheet online using the built-in PDF viewer.

Text of the manual

E3X-MDA Super Dual Fiber Sensors

1 Super Dual Fiber Sensors E3X-MDA The remarkable, new-dimension 2-channel amplifiers • The thinnest profile in the industry, at only 5 mm per channel. • AND/OR control output. • Flexible control from the Mobile Console. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Ordering Information ■ Amplifier Units Amplifier Units with Cables Amplifier Units with Connectors ■ Amplifier Unit Connectors (Order Separately) Item Appearance Functions Model NPN output PNP output 2-channel models AND/OR output E3X-MDA11 E3X-MDA41 Item Appearance Functions Model NPN output PNP output 2-channel models AND/OR output E3X-MDA6 E3X-MDA8 Item Appearance Cable length No. of conductors Model Master Connector 2 m 3 E3X-CN11 4 E3X-CN21 Slave Connector 1 E3X-CN12 2 E3X-CN22

E3X-MDA Super Dual Fiber Sensors

Combining Amplifier Units and Connectors Amplifier Units and Connectors are sold separately. Refer to the following tables when placing an order. When Using 5 Amplifier Units ■ Mobile Console (Order Separately) Note:Use the E3X-MC11-S Mobile Console for the E3X-DA-S/MDA-series Amplifier Units. Other Mobile Consoles cannot be used. ■ Accessories (Order Separately) Mounting Bracket End Plate Amplifier Unit Applicable Connector (Order Separately) Model NPN output PNP output Master Connector Slave Connector 2-channel models E3X-MDA6 E3X-MDA8 + E3X-CN21 (4-wire) E3X-CN22 (2-wire) Amplifier Units (5 Units) + 1 Master Connector + 4 Slave Connectors Appearance Model Remarks E3X-MC11-S (model number of set) Mobile Console with Head, Ca- ble, and AC adapter provided as accessories E3X-MC11-C1-S Mobile Console E3X-MC11-H1 Head E39-Z12-1 Cable (1.5 m) Appearance Model Quantity E39-L143 1 Appearance Model Quantity PFP-M 1

E3X-MDA Super Dual Fiber Sensors

3 Specifications ■ Ratings/Characteristics Amplifier Units *1: When differential output is selected for the output setting, the second channel output is 200 µs for operation and reset respectively. *2: Communications are disabled if the detection mode is selected during super-high-speed mode, and the communications functions for mutual interference prevention and the Mobile Console will not function. *3: Mutual interference prevention can be used for up to 5 Units (10 channels) if power tuning is enabled. Type 2-channel models Model NPN output E3X-MDA11 E3X-MDA6 Item PNP output E3X-MDA41 E3X-MDA8 Light source (wavelength) Red LED (635 nm) Supply voltage 12 to 24 VDC ±10%, ripple (p-p) 10% max. Power consumption 1,080 mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC) Control output Load power supply voltage: 26.4 VDC; open collector; load current: 50 mA max.; residual voltage: 1 V max. Circuit protection Reverse polarity for power supply connection, output short-circuit Response time Super- high- speed mode NPN 130 µs*1 for operation and reset respectively PNP Standard mode 1 ms for operation and reset respectively High-resolution mode 4 ms for operation and reset respectively Sensitivity setting Teaching or manual method Functions Power tuning Light emission power and reception gain, digital control method Timer function Select from OFF-delay, ON-delay, or one-shot timer. 1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments) Automatic power control (APC) High-speed control method for emission current Zero-reset Display can be reset to zero when required (negative values can be displayed). Initial reset Settings can be returned to defaults as required. Mutual interference prevention Possible for up to 9 Units (18 channels)*2, *3 I/O settings Output setting (Select from channel 2 output, AND, OR, leading edge sync, falling edge sync, or differ- ential output) Display Operation indicator for channel 1 (orange), Operation indicator for channel 2 (orange) Digital display Select from the following: Incident level for channel 1 + incident level for channel 2, Incident level + threshold, incident level percentage + threshold, incident light peak level + no incident light bottom level, minimum incident light peak level + maximum no incident light bottom level, long bar display, incident level + peak hold, incident level + channel Display orientation Switching between normal/reversed display is possible. Ambient illumination (receiver side) Incandescent lamp: 10,000 lux max. Sunlight: 20,000 lux max. Ambient temperature Operating: Groups of 1 to 2 Amplifiers: −25°C to 55°C Groups of 3 to 10 Amplifiers: −25°C to 50°C Groups of 11 to 16 Amplifiers: −25°C to 45°C (with no icing or condensation) Storage: −30°C to 70°C (with no icing or condensation) Ambient humidity Operating and storage: 35% to 85% (with no condensation) Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute Vibration resistance (destruction) 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions Shock resistance (destruction) 500 m/s2, for 3 times each in X, Y and Z directions Enclosure rating IEC 60529 IP50 (with Protective Cover attached) Connection method Prewired cable Standard connector Weight (packed state) Approx. 100 g Approx. 55 g Materials Case Polybutylene terephthalate (PBT) Cover Polycarbonate (PC) Accessories Instruction sheet

E3X-MDA Super Dual Fiber Sensors

Amplifier Unit Connectors Mobile Console Item E3X-CN11/21/22 E3X-CN12 Rated current 2.5 A Rated voltage 50 V Contact resistance 20 mΩ max. (20 mVDC max., 100 mA max.) (The figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of the cable.) No. of insertions (destruction) 50 times (The figure for the number of insertions is for connection to the Amplifier Unit and the adjacent Connector.) Materials Housing Polybutylene terephthalate (PBT) Contacts Phosphor bronze/gold-plated nickel Weight (packed state) Approx. 55 g Approx. 25 g Item E3X-MC11-S Supply voltage Charged with AC adapter Connection method Connected via adapter Weight (packed state) Approx. 580 g (Console only: 120 g) Refer to Operation Manual provided with the Mobile Console for de- tails.

E3X-MDA Super Dual Fiber Sensors

5 Ordering Information: Fiber Units ■ Through-beam Fiber Units Note 1. Indicates models that allow free cutting. Models without this mark do not allow free cutting. 2. The size of standard sensing object is the same as the fiber core diameter (lens diameter for models with lens). 3. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing dis- tance and sensitivity set to optimum values. Long-distance Fiber Units Features Appearance Applicable Amplifier Unit Sensing distance (mm) (Parentheses: With E39-F1 Lens Unit) Standard object (min. sensing object) (Parentheses: Opaque object) Model Permissi- ble bend- ing radius M4 E3X-MDA 1.4-mm dia. (0.01-mm dia.) E32-T11L 25 mm 3-mm dia. E3X-MDA E32-T12L M3 E3X-MDA 0.9-mm dia. (0.005-mm dia.) E32-T21L 10 mm 2-mm dia.; small di- ameter E3X-MDA E32-T22L M14; with lens; ide- al for explosion- proof applications E3X-MDA 10-mm dia. E32-T17L 25 mm : High-resolution mode : Super-high-speed mode : Standard mode M4 screw 350 (840) 1,100 (2,600)*1 870 (2,000) 3-mm dia. 350 1,100 870 M3 screw 340 260 100 2-mm dia. 340 260 100 M14 screw 13,000 10,000 4,000 Conventional Fiber Flexible Fiber Conventional fiber uses just one core and one cladding section. Bending the fiber may break it or reduce the light intensity. Flexible fiber contains multiple independent cores all surrounded by cladding. The fiber can be bent without breaking or reducing the light intensity. Core Cladding Flexible fiber models are indicated by an "R" at the end of the model number. Flexible fiber contains multiple cores. These cores are all surrounded by cladding, giving a minimum bending radius of 1 mm. The fiber can be bent at right angles without affecting the light intensity. Handle it just like any other cable. A Wide Range of Flexible Fibers for Easy Installation without Loss of Light Intensity

E3X-MDA Super Dual Fiber Sensors

General-purpose Fiber Units * The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm. Fiber Units with Thin Heads Features Appearance Applicable Amplifier Unit Sensing distance (mm) (Parentheses: With E39-F1 Lens Unit) Standard object (min. sensing object) (Parentheses: Opaque object) Model Permissi- ble bend- ing radius M4 E3X-MDA 1.0-mm dia. (0.005-mm dia.) E32-TC200 25 mm M4 E3X-MDA E32-T11R 1 mm M4 Fiber sheath mate- rial: fluororesin E3X-MDA E32-T11U 4 mm 3-mm dia. E3X-MDA E32-T12R 1 mm M3 Possible to mount the E39-F5 Reflec- tive Side-view Con- version Attachment E3X-MDA E32-TC200A 25 mm M3; for detecting minute sensing ob- jects E3X-MDA 0.5-mm dia. (0.005-mm dia.) E32-TC200E 10 mm M3 E3X-MDA E32-T21R 1 mm M4 screw 500 (3,700) 200 (1,500) 650 (4,000)* M4 screw 140 (970) 350 (2,400) 450 (3,100) M4 screw 180 (930) 580 (3,000)* 450 (2,300) 3-mm dia. 140 350 450 M3 screw 180 450 580 M3 screw 50 130 170 M3 screw 75 100 30 Features Appearance Applicable Amplifier Unit Sensing distance (mm) (Parentheses: With E39-F1 Lens Unit) Standard object (min. sensing object) (Parentheses: Opaque object) Model Permissi- ble bend- ing radius 2-mm dia.; for de- tecting minute sensing objects E3X-MDA 0.5-mm dia. (0.005-mm dia.) E32-T22 10 mm 2-mm dia.; for de- tecting minute sensing objects E3X-MDA E32-T22R 1 mm 1.2-mm dia.; with sleeve E3X-MDA 1.0-mm dia. (0.005-mm dia.) E32-TC200B E32-TC200B4 25 mm 0.9-mm dia.; with sleeve E3X-MDA 0.5-mm dia. (0.005-mm dia.) E32-TC200F E32-TC200F4 10 mm 2-mm dia. 50 130 170 2-mm dia. 75 100 30 1.2-mm dia. M4 screw 90 mm (40 mm) ( ): E32- TC200B4 200 500 650 M3 screw 0.9-mm dia. 90 mm (40 mm) ( ): E32- TC200F4 50 130 170

E3X-MDA Super Dual Fiber Sensors

7 Flexible Fiber Units (Resists Breaking) (R4) * The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm. Side-view Fiber Units Features Appearance Applicable Amplifier Unit Sensing distance (mm) (Parentheses: With E39-F1 Lens Unit) Standard object (min. sensing object) (Parentheses: Opaque object) Model Permissi- ble bend- ing radius Ideal for mounting on moving sections (R4) E3X-MDA 1.0-mm dia. (0.005-mm dia.) E32-T11 4 mm E3X-MDA 0.5-mm dia. (0.005-mm dia.) E32-T21 E3X-MDA E32-T22B M4 screw 180 (930) 580 (3,000) 450 (2,300) M3 screw 45 110 150 1.5-mm dia. 45 110 150 Features Appearance Applicable Amplifier Unit Sensing distance (mm) (Parentheses: With E39-F1 Lens Unit) Standard object (min. sensing object) (Parentheses: Opaque object) Model Permissi- ble bend- ing radius Long distance; space-saving E3X-MDA 1.0-mm dia. (0.005-mm dia.) E32-T14L 25 mm Space-saving E3X-MDA E32-T14LR 1 mm Suitable for detect- ing minute sensing objects; small di- ameter E3X-MDA 0.5-mm dia. (0.005-mm dia.) E32-T24 10 mm Suitable for detect- ing minute sensing objects; small di- ameter E3X-MDA E32-T24R 1 mm Screw-mounting type E3X-MDA 4-mm dia. (0.1-mm dia.) E32-T14 25 mm 3-mm dia. 120 300 390 3-mm dia. 50 130 170 1-mm dia. 70 100 30 1-mm dia. 35 27 10 2,900 2,200 900

E3X-MDA Super Dual Fiber Sensors

Chemical-resistant Fiber Units Features Appearance Applicable Amplifier Unit Sensing distance (mm) (Parentheses: With E39-F1 Lens Unit) Standard object (min. sensing object) (Parentheses: Opaque object) Model Permissi- ble bend- ing radius Fluororesin-cov- ered; round head that resists water drops E3X-MDA 4-mm dia. (0.1-mm dia.) E32-T11F 4 mm Fluororesin-cov- ered; withstands chemicals and harsh environ- ments (operating ambient temperature: −30°C to 70°C) E3X-MDA 4-mm dia. (0.1-mm dia.) E32-T12F 40 mm Fluororesin-cov- ered; withstands chemicals and harsh environ- ments; side-view (operating ambient temperature: −30°C to 70°C) E3X-MDA 3-mm dia. (0.1-mm dia.) E32-T14F Fluororesin; with- stands chemicals and harsh environ- ments (operating ambient temperature: −40°C to 200°C) E3X-MDA 1.0-mm dia. (0.005-mm dia.) E32-T81F-S 10 mm 7.2-mm dia. 1,600 1,300 520 5-mm dia. 2,600 2,000 800 5-mm dia. 320 250 100 6-mm dia. 600 460 190

E3X-MDA Super Dual Fiber Sensors

9 Heat-resistant Fiber Units *1: For continuous operation, use the products within a temperature range of −40°C to 130°C. *2: Indicates the heat-resistant temperature at the fiber tip. Fiber Unit with Slot Sensor Features Appearance Applicable Amplifier Unit Sensing distance (mm) (Parentheses: With E39-F1 Lens Unit) Standard object (min. sensing object) (Parentheses: Opaque object) Model Permissi- ble bend- ing radius Resists 150°C*1; fi- ber sheath materi- al: fluororesin (operating ambient temperature: −40°C to 150°C) E3X-MDA 1.5-mm dia. (0.1-mm dia.) E32-T51 35 mm Resists 200°C; flex- ible (R10); fiber sheath material: fluororesin (operating ambient temperature: −40°C to 200°C) E3X-MDA 1.0-mm dia. (0.005-mm dia.) E32-T81R-S 10 mm Resists 350°C*2, with spiral tube; high mechanical strength; fiber sheath material: stainless steel (operating ambient temperature: −60°C to 350°C) E3X-MDA E32-T61-S 25 mm Side-view; resists 150°C*1; suitable for detecting minute sensing objects; fi- ber sheath materi- al: fluororesin (operating ambient temperature: –40°C to 150°C) E3X-MDA E32-T54 35 mm Resists 200°C*2; L- shaped; fiber sheath material: stainless steel E3X-MDA 1.7-mm dia. (0.1-mm dia.) E32-T84S-S 25 mm M4 screw 650 500 200 M4 screw 230 (1,700) 180 (1,300) 70 (520) M4 screw 390 (3,000) 300 (2,200) 120 (900) 2-mm dia. 190 150 60 3-mm dia. 1,100 870 350 Features Appearance Applicable Amplifier Unit Sensing distance (mm) (Parentheses: With E39-F1 Lens Unit) Standard object (min. sensing object) (Parentheses: Opaque object) Model Permissi- ble bend- ing radius Suitable for film sheet detection; no optical axis adjust- ment required; easy to mount E3X-MDA 4-mm dia. (0.1-mm dia.) E32-G14 25 mm 10 10 10

E3X-MDA Super Dual Fiber Sensors

Fiber Units with a Narrow Vision Field Area-sensing Fiber Units *1: These figures are for a sensing distance of 300 mm. (Figures for the diameter of sensing objects are in the still state.) *2: These figures are ones for which detection is possible in each sensing area at a digital incident level of 1,000. (Figures for the diameter of sensing objects are in the still state.) Features Appearance Applicable Amplifier Unit Sensing distance (mm) (Parentheses: With E39-F1 Lens Unit) Standard object (min. sensing object) (Parentheses: Opaque object) Model Permissi- ble bend- ing radius Suitable for detect- ing wafers E3X-MDA 1.7-mm dia. (0.1-mm dia.) E32-T22S 25 mm Side-view; suitable for detecting wafers E3X-MDA 2-mm dia. (0.1-mm dia.) E32-T24S 10 mm 3-mm dia. 1,600 1,250 500 3.5 × 3-mm dia. 1,100 870 350 Features Appearance Applicable Amplifier Unit Sensing distance (mm) (Parentheses: With E39-F1 Lens Unit) Standard object (min. sensing object) (Parentheses: Opaque object) Model Permissi- ble bend- ing radius Multi-point detec- tion (4-head) E3X-MDA 2-mm dia. (0.1-mm dia.) E32-M21 25 mm Detects in a 30-mm area E3X-MDA (0.3-mm dia.)*1 E32-T16W 10 mm E3X-MDA E32-T16WR 1 mm Side-view; suitable for applications with limited spatial depth E3X-MDA (0.2-mm dia.)*1 E32-T16J 10 mm E3X-MDA E32-T16JR 1 mm Suitable for detect- ing over a 10-mm area; long distance E3X-MDA (0.6-mm dia.)*2 E32-T16 25 mm Stable for detecting minute sensing ob- jects in a wide area E3X-MDA (0.2-mm dia.)*1 E32-T16P 10 mm E3X-MDA E32-T16PR 1 mm M3 screw 470 360 140 30 mm 1,400 1,100 450 30 mm 1,100 860 340 11 mm 800 650 260 11 mm 600 480 190 10 mm 2,400 1,800 740 11 mm 970 750 300 11 mm 730 560 220

E3X-MDA Super Dual Fiber Sensors

11 ■ Fiber Units with Reflective Sensors Note 1. Indicates models that allow free cutting. Models without this mark do not allow free cutting. 2. The values for the minimum sensing object are representative values that indicate values obtained in standard mode with the sensing dis- tance and sensitivity set to optimum values. 3. When set to the maximum sensitivity setting, internal light reflection may cause the sensor to detect incident light. In such case, use adjust the threshold either manually or using teaching. Long-distance Fiber Units * Values are sensed for white paper (standard sensing object). General-purpose Fiber Units * Values are sensed for white paper (standard sensing object). Features Appearance Applicable Amplifier Unit Sensing distance (mm)* Standard object (min. sensing object: Gold wire) Model Permissi- ble bend- ing radius M6 E3X-MDA 500×500 (0.005-mm dia.) E32-D11L 25 mm 3-mm dia.; small di- ameter E3X-MDA 300×300 (0.005-mm dia.) E32-D12 M4 E3X-MDA 200×200 (0.005-mm dia.) E32-D21L 10 mm 3-mm dia.; small di- ameter E3X-MDA E32-D22L Square head, su- per-long distance E3X-MDA 300×300 E32-D16 4 mm M6 screw 400 270 110 3-mm dia. 230 160 70 M4 screw 130 85 35 3-mm dia. 130 85 35 17.5 mm 40 to 490 40 to 600 40 to 240 Features Appearance Applicable Amplifier Unit Sensing distance (mm)* Standard object (min. sensing object: Gold wire) Model Permissi- ble bend- ing radius M6 E3X-MDA 400×400 (0.005-mm dia.) E32-DC200 25 mm M6 E3X-MDA 300×300 (0.005-mm dia.) E32-D11R 1 mm M6 Fiber sheath mate- rial: fluororesin E3X-MDA E32-D11U 4 mm 3-mm dia. E3X-MDA E32-D12R 1 mm M3; small diameter E3X-MDA 100×100 (0.005-mm dia.) E32-DC200E 10 mm M3; small diameter E3X-MDA 50×50 (0.005-mm dia.) E32-D21R 1 mm 3-mm dia.; small di- ameter E3X-MDA E32-D22R M6 Screw 300 210 90 M6 screw 300 170 50 M6 screw 170 125 50 3-mm dia. 170 120 50 M3 screw 80 55 22 M3 screw 30 22 8 3-mm dia. 30 22 8

E3X-MDA Super Dual Fiber Sensors

Fiber Units with Thin Heads * Values are sensed for white paper (standard sensing object). Flexible Fiber Units (Resists Breaking) (R4) * Values are sensed for white paper (standard sensing object). Features Appearance Applicable Amplifier Unit Sensing distance (mm)* Standard object (min. sensing object: Gold wire) Model Permissi- ble bend- ing radius 2.5-mm dia.; with sleeve E3X-MDA 400×400 (0.005-mm dia.) E32-DC200B E32-DC200B4 25 mm 1.2-mm dia.; with sleeve E3X-MDA 100×100 (0.005-mm dia.) E32-DC200F E32-DC200F4 10 mm 0.8-mm dia.; for de- tecting minute sensing objects E3X-MDA 25×25 (0.005-mm dia.) E32-D33 4 mm 0.5-mm dia.; for de- tecting very minute sensing objects E3X-MDA E32-D331 Features Appearance Applicable Amplifier Unit Sensing distance (mm)* Standard object (min. sensing object: Gold wire) Model Permissi- ble bend- ing radius Ideal for mounting on moving sections (R4) E3X-MDA 300×300 (0.005-mm dia.) E32-D11 4 mm E3X-MDA 50×50 (0.005-mm dia.) E32-D21 E3X-MDA 100×100 (0.005-mm dia.) E32-D21B E3X-MDA 50×50 (0.005-mm dia.) E32-D22B 2.5-mm dia. M6 screw 90 mm (40 mm) ( ): E32- DC200B4 300 210 90 1.2-mm dia. M3 screw 90 mm (40 mm) ( ): E32- DC200F4 80 55 22 3-mm dia. 0.8-mm dia. 16 10 4 2-mm dia. 0.5-mm dia. 3 2 0.8 M6 screw 170 125 50 M3 screw 30 22 8 M4 screw 70 50 20 1.5-mm dia. 30 22 8

E3X-MDA Super Dual Fiber Sensors

13 Coaxial Fiber Units * Values are sensed for white paper (standard sensing object). Side-view Fiber Units * Values are sensed for white paper (standard sensing object). Chemical-resistant Fiber Units * Values are sensed for white paper (standard sensing object). Features Appearance Applicable Amplifier Unit Sensing distance (mm)* Standard object (min. sensing object: Gold wire) Model Permissi- ble bend- ing radius M6 coaxial; high- precision positioning E3X-MDA 500×500 (0.005-mm dia.) E32-CC200 25 mm 3-mm dia.; small di- ameter; coaxial; high-precision posi- tioning E3X-MDA 300×300 (0.005-mm dia.) E32-D32L M3 coaxial; high- precision positioning E3X-MDA 100×100 (0.005-mm dia.) E32-C31 M3 coaxial; high- precision positioning E3X-MDA 50×50 (0.005-mm dia.) E32-C41 2-mm dia. coaxial; high-precision posi- tioning E3X-MDA E32-C42 2-mm dia. coaxial; high-precision posi- tioning E3X-MDA 100×100 (0.005-mm dia.) E32-D32 Features Appearance Applicable Amplifier Unit Sensing distance (mm)* Standard object (min. sensing object: Gold wire) Model Permissi- ble bend- ing radius 6-mm dia.; long dis- tance E3X-MDA 200×200 (0.005-mm dia.) E32-D14L 25 mm 6-mm dia. E3X-MDA 100×100 (0.005-mm dia.) E32-D14LR 1 mm 2-mm dia.; small di- ameter; space-sav- ing E3X-MDA 50×50 (0.005-mm dia.) E32-D24 10 mm E3X-MDA E32-D24R 1 mm Features Appearance Applicable Amplifier Unit Sensing distance (mm)* Standard object (min. sensing object: Gold wire) Model Permissi- ble bend- ing radius Fluororesin-cov- ered; withstands chemicals and harsh environments (oper- ating ambient tem- perature: −30°C to 70°C E3X-MDA 200×200 (0.005-mm dia.) E32-D12F 40 mm M6 screw 300 210 90 3-mm dia. 150 100 45 M3 screw 75 50 22 M3 screw 35 22 8 2-mm dia. 35 22 8 2-mm dia. 75 52 22 6-mm dia. 110 80 36 6-mm dia. 45 33 14 2-mm dia. 30 22 8 2-mm dia. 15 10 4 6-mm dia. 95 70 30

E3X-MDA Super Dual Fiber Sensors

Heat-resistant Fiber Units *1: Values are sensed for white paper (standard sensing object). *2: For continuous operation, use the products within a temperature range of −40°C to 130°C. *3: Indicates the heat-resistant temperature at the fiber tip. Area-sensing Fiber Units * Values are sensed for white paper (standard sensing object). Retroreflective Fiber Units * Values are sensed for white paper (standard sensing object). Features Appearance Applicable Amplifier Unit Sensing distance (mm)*1 Standard object (min. sensing object: Gold wire) Model Permissi- ble bend- ing radius Resists 150°C*2; fi- ber sheath materi- al: fluororesin (operating ambient temperature: −40°C to 150°C) E3X-MDA 200×200 (0.005-mm dia.) E32-D51 35 mm Resists 200°C*3; fi- ber sheath materi- al: fluororesin (operating ambient temperature: −40°C to 200°C) E3X-MDA E32-D81R-S 10 mm Resists 350°C*3; fi- ber sheath materi- al: stainless steel (operating ambient temperature: −60°C to 350°C) E3X-MDA E32-D61-S 25 mm Resists 400°C*3; fi- ber sheath materi- al: stainless steel (operating ambient temperature: −40°C to 400°C) E3X-MDA 100×100 (0.005-mm dia.) E32-D73-S Features Appearance Applicable Amplifier Unit Sensing distance (mm)* Standard object (min. sensing object: Gold wire) Model Permissi- ble bend- ing radius Side-view; detec- tion over wide ar- eas E3X-MDA 300×300 (0.005-mm dia.) E32-D36P1 25 mm Features Appearance Applicable Amplifier Unit Sensing distance (mm)* Standard object (min. sensing ob- ject: Gold wire) Model Permissi- ble bend- ing radius Transparent object detection E3X-MDA 35-mm dia. (0.1-mm dia.) E32-R21 + E39-R3 (Attachment) 10 mm Transparent object detection (operat- ing ambient tem- perature: −25°C to 55°C); degree of protection: IEC60529 IP66 E3X-MDA 35-mm dia. (0.2-mm dia.) E32-R16 + E39-R1 (Attachment) 25 mm M6 screw 230 165 72 M6 screw 90 63 27 M6 screw 90 60 27 M4 screw 1.25-mm dia. 60 40 18 150 100 45 M6 screw Reflector E39-R3 10 to 250 10 to 250 10 to 250 Reflector E39-R1 150 to 1,500 150 to 1,500 150 to 1,500

E3X-MDA Super Dual Fiber Sensors

15 Limited-reflective Fiber Units * Values are sensed for white paper (standard sensing object). Features Appearance Applicable Amplifier Unit Sensing distance (mm)* Standard object (min. sensing ob- ject: Gold wire) Model Permissi- ble bend- ing radius Suitable for posi- tioning liquid crystal glass E3X-MDA 100×100 Soda glass with re- flection factor of 7% E32-L16 25 mm Suitable for posi- tioning liquid crystal glass E3X-MDA E32-L56E1 E32-L56E2 35 mm Suitable for posi- tioning liquid crystal glass (Resists 300°C) E3X-MDA E32-L66 25 mm Liquid crystal glass, mounting detec- tion, small E3X-MDA 25×25 (0.005-mm dia.) E32-L24S 10 mm Detects wafers and small differences in height; (operating ambient tempera- ture: −40°C to 105°C); degree of protection: IEC60529 IP50 E3X-MDA E32-L24L 10 mm E3X-MDA E32-L25L Detects wafers and small differences in height; degree of protection: IEC60529 IP50 E3X-MDA E32-L25 25 mm E3X-MDA E32-L25A 0 to 15 0 to 15 0 to 15 4 to 12 4 to 12 4 to 12 5 to 18 5 to 18 5 to 18 0 to 4 0 to 4 0 to 4 4±2 4±2 4±2 7.2±1.8 7.2±1.8 7.2±1.8 3.3 3.3 3.3 3.3 3.3 3.3

E3X-MDA Super Dual Fiber Sensors

Fluid-level Detection Fiber Units Mapping Sensors (Through-beam) Features Appearance Applicable Amplifier Unit Sensing distance (mm) Standard object (min. sensing object: Gold wire) Model Permissi- ble bend- ing radius Fluid contact type: unbendable section L 150 mm, 350 mm (two types); (oper- ating ambient tem- perature: −40°C to 200°C) E3X-MDA --- Pure water at 25°C E32-D82F1 E32-D82F2 40 mm Tube-mounting type; Light ON when fluid is present; minimal in- fluence from bub- bles and water drops E3X-MDA Applicable tube: Transparent tube Tube diameter: 3.2, 6.4, or 9.5 mm (Tube must be FEP or material with equivalent transparency; recom- mended wall thickness: 1 mm) E32-A01 4 mm Tube-mounting type; light ON when fluid is present; minimal influence from bubbles and water drops E3X-MDA Applicable tube: Transparent tube Tube diameter: 6 to 13 mm (Tube must be FEP or material with equivalent transparency; recom- mended wall thickness: 1 mm) E32-A02 Tube-mounting type; dense mount- ing to detect level differences of 4 mm E3X-MDA Applicable tube: Transparent tube Tube diameter: 8 to 10 mm (Tube must be FEP or material with equivalent transparency; recom- mended wall thickness: 1 mm) E32-L25T 10 mm Tube-mounting type; unlimited tube diameter; minimal influence from bub- bles and water drops E3X-MDA Applicable tube: Transparent tube Tube diameter: No restriction (Tube must be FEP or material with equivalent transparency) E32-D36F 4 mm Features Appearance Applicable Amplifier Unit Sensing distance (mm) Standard object (min. sensing object: Gold wire) Model Permissi- ble bend- ing radius Super-narrow vi- sion field; side- view; opening an- gle: 1.5°; simple adjustment E3X-MDA 2-mm dia. (0.1-mm dia.) E32-A03 1 mm Super-narrow vi- sion field; small; side-view; opening angle: 3°; simple adjustment E3X-MDA 1.2-mm dia. (0.1-mm dia.) E32-A04 10 mm L 3-mm dia. 750 580 250 2-mm dia. 300 220 100

E3X-MDA Super Dual Fiber Sensors

17 Output Circuits NPN Output Note 1. Time Charts for Timer Settings (T: Set Time) 2. Control Output (AND, OR, Sync) and Time Chart for Timer Settings (T: Set Time) Model Mode se- lector Timing chart Mode selector Output circuit E3X-MDA11 E3X-MDA6 LIGHT ON (L/ON) Light ON DARK ON (D/ON) Dark ON Incident light No incident light Operation indicator (orange) ON OFF Output transistor ON OFF Load (relay) Operate Release (Between brown and black) CH1/ CH2 Display Operation indicator (orange) ch 2 Photo- electric Sensor main circuit Brown Black Load Control output 1 Blue 12 to 24 VDC Operation indicator (orange) ch 1 Load Control output 2 Orange Incident light No incident light Operation indicator (orange) ON OFF Output transistor ON OFF Load (relay) Operate Release (Between brown and black) CH1/ CH2 ON delay OFF delay One-shot ON OFF ON OFF L-ON D-ON T T Incident light No incident light L-ON D-ON T T Incident light No incident light ON OFF ON OFF L-ON D-ON T T Incident light No incident light ON OFF ON OFF CH1 CH2 ON OFF ON OFF ON OFF ON OFF ON OFF OUT (sync) OUT (OR) OUT (AND) T CH1 CH2 ON OFF ON OFF ON OFF ON OFF ON OFF (AND) OFF delay (AND) ON delay (AND) T T T One-shot

E3X-MDA Super Dual Fiber Sensors

PNP Output Note 1. Time Charts for Timer Settings (T: Set Time) 2. Control Output (AND, OR, Sync) and Time Chart for Timer Settings (T: Set Time) Model Mode se- lector Timing chart State of output transistor Output circuit E3XMDA41 E3X-MDA8 LIGHT ON (L/ON) Light ON DARK ON (D/ON) Dark ON CH1/ CH2 Incident light No incident light Operation indicator (orange) ON OFF Output transistor ON OFF Load (relay) Operate Release (Between blue and black) Photo- electric Sensor main circuit Brown Black Load Control output 1 Blue 12 to 24 VDC Load Control output 2 Orange Display Operation indicator (orange) ch 2 Operation indicator (orange) ch 1 CH1/ CH2 Incident light No incident light Operation indicator (orange) ON OFF Output transistor ON OFF Load (relay) Operate Release (Between blue and black) ON delay OFF delay One-shot ON OFF ON OFF L-ON D-ON T T Incident light No incident light ON OFF ON OFF L-ON D-ON T T Incident light No incident light ON OFF ON OFF L-ON D-ON T Incident light No incident light T CH1 CH2 ON OFF ON OFF ON OFF ON OFF ON OFF OUT (sync) OUT (OR) OUT (AND) T CH1 CH2 ON OFF ON OFF ON OFF ON OFF ON OFF (AND) OFF delay (AND) ON delay (AND) T T T One-shot

E3X-MDA Super Dual Fiber Sensors

19 Nomenclature ■ Amplifier Units Adjustment Methods 1. Setting the Operation Mode The operation mode is set in SET mode. Refer to 5. Setting Func- tions in SET Mode on page 21. Set the Channel Selector to the desired channel before making any adjustments or settings. This is true for all adjustments and settings. 2. Adjusting the Power (RUN Mode) The current incident light level can be adjusted to near the power tuning target value (default: 2,000). Confirm that the MODE key setting is PTUN (power tuning). The default setting is PTUN. Refer to 5. Setting Functions in SET Mode on page 21. * Setting Errors An error has occurred if one of the following displays appears after the progress bar is displayed. Note:Press the DOWN key right after pressing the MODE key. 3. Setting Thresholds Manually (RUN Mode) A threshold can be set manually. A threshold value can also be fine- tuned using manual setting after teaching. * Even if the display method for display switching is changed, the threshold will appear on the sub-display when the key is pressed. UP DOWN MODE Lock Button Locks the fiber. Operation Keys Function setting operations Channel Selector Mode Selector Use to select SET or RUN mode. ON when output is ON. OFF when output is OFF. Sub-Display (Green) Threshold, function settings, etc. Main Display (Red) Incident level, function, etc. E3X-MDA@ Operation Indicator for Channel 2 (orange) Operation Indicator for Channel 1 (orange) ON when output is ON. OFF when output is OFF. 3 s MODE RUN Release the key after the progress bar is displayed. The Power Tuning indicator will light when the adjustment has been completed. Light level Threshold (default) PTUN Progress bar Display changes after specific time. Power tuning target value Light level Threshold Set the Mode Se- lector to RUN. (Factory-set to RUN) Display Error Action Over Error The incident light level is too low for the power tuning target value. The power will not be tuned. The power can be increased up to ap- proximately 5 times the incident light value. Bottom Error The incident light level is too high for the power tun- ing target value. The power will be tuned to the minimum level. The power can be decreased down to approximately 1/25th the incident light value. DOWN MODE 3 s The Power Tuning indicator will go out when the default setting has been restored. "OFF" will flash twice. To restore the default power settings: PTUN OFF Light level Threshold Press together (see note). PTUN OVER Flashes twice PTUN BOTM Flashes twice UP DOWN Light level Increases threshold. Decreases threshold. Threshold (default) RUN Set the Mode Se- lector to RUN. (Factory-set to RUN)

E3X-MDA Super Dual Fiber Sensors

4. Teaching the Threshold Value (SET Mode) * There are four methods that can be used for teaching, as described below. Use the method most suitable for the application. * An error has occurred if OVER, LO, or NEAR is displayed on the sub-display. Repeat the operation from the beginning. 4-1. Setting the Threshold at Maximum Sensitivity The threshold can be set at the maximum sensitivity. This method is ideal when using a Through-beam Fiber Unit to detect workpieces so that detection is not influenced to any great degree by dust and other environmental factors. 4-2. Teaching a Through-beam Fiber Unit without a Workpiece A value about 6% less than the incident light level can be set as the threshold value. This method is ideal when detecting very small dif- ferences in light level, such as when detecting very fine workpieces or transparent workpieces like transparent fibers. 4-3. Teaching a Reflective Fiber Unit without a Workpiece A value about 6% greater than the incident light level can be set as the threshold value. This method is ideal when using a Reflective Fiber Unit to detect workpieces so that detection is not influenced to any great degree by dust and other environmental factors. 4-4. Teaching With and Without a Workpiece Teaching can be performed twice, once with and once without a workpiece, and the value between the two measured value can be set as the threshold. UP DOWN SET The threshold value that was set will flash twice. Light level Threshold FULL Threshold The previous display will return when the setting has been completed. Light level Threshold Set the Mode Selector to SET. Either for 3 s UP DOWN RUN "- - - -" will be displayed. With no workpiece: The previous display will return when the setting has been completed. The set threshold value will flash twice. Threshold TECH - - - - Light level Threshold THRU Threshold Either for 1 s To RUN Light level SET Set the Mode Selector to SET. UP DOWN UP DOWN SET "- - - -" will be displayed. With no workpiece: The previous display will return when the setting has been completed. The set threshold value will flash twice. Light level Threshold TECH - - - - Light level Threshold RFCH Threshold Set the Mode Selector to SET. Either for 1 s Either for 3 s UP DOWN UP DOWN Workpiece SET "- - - -" will be displayed. With a workpiece: The previous display will return when the setting has been completed. The set threshold value will flash twice. Light level Threshold TECH - - - - Light level Threshold RFCH Threshold Set the Mode Selector to SET. With no workpiece:. Either for 1 s Either for 1 s

E3X-MDA Super Dual Fiber Sensors

21 5. Setting Functions in SET Mode * The default settings are shown in the transition boxes between functions. UP DOWN MODE UP DOWN MODE UP DOWN MODE MODE UP DOWN MODE *1 MODE Key UP DOWN UP DOWN MODE L-PE D-BT L-BT D-PE PEAK CH1 light level UP DOWN MODE MODE UP DOWN MODE SET Dark ON Light ON Set the Mode Selector to SET. Light Level and Threshold Display Switch to desired function. Detection Changes the setting. Operation mode Standard mode Super-high-speed mode High-resolution mode Timer (To use the timer function) OFF-delay timer Timer disabled ON-delay timer One-shot timer Time Enables the timer. 20 to 200 ms 200 ms to 1 s 5-ms increments 1 to 20 ms 1-ms increments 100-ms increments 1 to 5 s 1-s increments Setting range: 1 to 5,000 ms Display switch (To change the display method) (To change the function of the MODE key during operation) Executes a zero reset. Executes power tuning. Power tuning target value Setting range: 100 to 3,900 (increments of 100) Maximum power Display orientation (To reverse the orientation of the display.) Up/down reversed display Normal display *1 The display will be switched as shown below. Light levels for channels 1 and 2 Light level Threshold The incident light level and the threshold value. % light level Threshold The incident light level as a percentage of the threshold value and the threshold value. The incident light peak level and no incident light bottom level. (Refreshed when output turns ON or OFF.) Detection status Analog bar display. The current detection status is displayed as an analog bar. The bar will lengthen from the right as ON status is reached. (ON: Red; OFF: Green) The current incident light level and the peak incident light level. Light level Light level Peak light level The incident light level and the channel. Light level Channel CH2 light level The min. incident light peak level and max. incident light bottom level, showing min. width of light level change. (Refreshed when output turns ON/OFF ten times.) Fixed interval Teaching: Refer to 4. Teaching the Threshold Value (SET Mode) on page 20. Refer to 1. Setting the Operation Mode on page 19. Refer to 2. Adjusting the Power (RUN Mode) on page 19.

E3X-MDA Super Dual Fiber Sensors

UP DOWN MODE UP DOWN MODE UP DOWN MODE Timer 5-ms increments 1 to 20 ms 1-ms increments 100-ms increments 1 to 5 s 1-s increments Setting range: 1 to 5,000 ms Output setting (To change the output content of channel 2) Timer disabled Timer enabled Timer time Sets the timer for the output of either AND or OR, depending Timer disabled OFF delay timer ON delay timer is selected, the one-shot timer is automati- cally set, i.e., the timer function cannot be selected. Output for each channel Output when the output is ON for both channels 1 and 2. Output when the output is ON for either channel 1 or channel 2. Rising edge sync. Output if channel 1 is ON when channel 2 changes from OFF to ON. Falling edge sync. Output if channel 1 is ON when channel 2 changes from ON to OFF. Operates according to the differ- ence between channels (channel 1 - channel 2). The difference value is used for both threshold and out- put judgement execution.

E3X-MDA Super Dual Fiber Sensors

23 ‘6. Convenient Functions 6-1. Zeroing the Digital Display The incident light level on the digital display can be set to 0. * Change the function to 0rst (zero reset) with the MODE key. The default setting is PTUN. 6-2. Locking the Keys All key operations can be disabled. Note:Press the DOWN or UP key right after pressing the MODE key. 6-3. Initializing Settings All settings can be returned to their original default settings. 3 s MODE 3 s MODE DOWN MODE RUN To reset to 0 again: To return to original value for incident light level: Set the Mode Selector to RUN Factory setting 3 s Press together (see note). MODE MODE UP UP RUN "OFF" will flash twice and key operations will be enabled. To release the lock: "ON" will flash twice and key operations will be disabled. LOC ON LOC OFF Set the Mode Selector to RUN. Factory setting * If a key is pressed while key operations are locked, "LOC" will flash twice on the display to indicate that key operations have been disabled. 3 s Press together (see note). 3 s Press together (see note). MODE MODE UP DOWN SET Settings initialized. Operation canceled. INIT NO? Set the Mode Selector to SET. INIT YES? UP DOWN 3 s Press together (see note).

E3X-MDA Super Dual Fiber Sensors

Safety Precautions Note:In addition to the following precautions, please read and ob- serve the common precautions for the instructions included with the product. ■ Precautions for Correct Use Amplifier Unit Installation ● Operation after Turning Power ON The Amplifier Unit is ready to operate within 200 ms after the power supply is turned ON. If the Sensor and load are connected to power supplies separately, be sure to turn ON the power supply to the Sen- sor first. Mounting ● Connecting and Disconnecting Connectors Mounting Connectors 1. Insert the Master or Slave Connector into the Amplifier Unit until it clicks into place. 2. Attach the protector seals (provided as accessories) to the sides of master and slave connectors that are not connected. Note:Attach the seals to the sides with grooves Removing Connectors 1. Slide the slave Amplifier Unit(s) for which the Connector is to be removed away from the rest of the group. 2. After the Amplifier Unit(s) has been separated, press down on the lever on the Connector and remove it. (Do not attempt to remove Connectors without separating them from other Amplifier Units first.) ● Joining and Removing Amplifier Units Joining Amplifier Units 1. Mount the Amplifier Units one at a time onto the DIN track. 2. Slide the Amplifier Units together, line up the clips, and press the Amplifier Units together until they click into place. Separating Amplifier Units Slide Amplifier Units away from each other, and remove from the DIN track one at a time. (Do not attempt to remove Amplifier Units from the DIN track without separating them first.) Note 1. The specifications for ambient temperature will vary accord- ing to the number of Amplifier Units used together. For de- tails, refer to Ratings/Characteristics. 2. Always turn OFF the power supply before joining or separat- ing Amplifier Units. ● Mounting the End Plate (PFP-M) An End Plate should be used if there is a possibility of the Amplifier Unit moving, e.g., due to vibration. If a Mobile Console is going to be mounted, connect the End Plate in the direction shown in the follow- ing diagram. ● Mounting the Mobile Console Head Leave a gap of at least 20 mm between the nearest Amplifier Unit and the Mobile Console head. Insert Seal Seal Press down Remove Lever Click into place End Plate 20 mm

E3X-MDA Super Dual Fiber Sensors

25 ● Fiber Connection The E3X Amplifier Unit has a lock button for easy connection of the Fiber Unit. Connect or disconnect the fibers using the following pro- cedures: 1. Connection Open the protective cover, insert the fibers according to the fiber insertion marks on the side of the Amplifier Unit, and lower the lock button. Fibers with E39-F9 Attachment Fibers That Cannot Be Free-Cut (with Sleeves) 2. Disconnecting Fibers Remove the protective cover and raise the lock button to pull out the fibers. Note 1. To maintain the fiber properties, confirm that the lock is re- leased before removing the fibers. 2. Be sure to lock or unlock the lock button within an ambient temperature range between −10°C and 40°C. Adjustments ● Mutual Interference Protection Function There may be some instability in the digital display values due to light from other sensors. If this occurs, decrease the sensitivity (i.e., decrease the power or increase the threshold) to perform stable detection. ● EEPROM Writing Error If the data is not written to the EEPROM correctly due to a power fail- ure or static-electric noise, initialize the settings with the keys on the Amplifier Unit. ERR/EEP will flash on the display when a writing error has occurred. ● Optical Communications Several Amplifier Units can be slid together and used in groups. Do not, however, slide the Amplifier Units or attempt to remove any of the Amplifier Units during operation. Other Precautions ● Protective Cover Always keep the protective cover in place when using the Amplifier Unit. ● Mobile Console Use the E3X-MC11-S Mobile Console for the E3X-DA-S-series and the E3X-MDA series Amplifier Units. Other Mobile Consoles, such as the E3X-MC11, cannot be used. Lock button Fiber Fiber insertion mark Locked Unlocked Insertion position Protective cover 9 mm Fiber Unit 9 mm 13 mm 9 mm 13 mm Locked Unlocked Protective cover

E3X-MDA Super Dual Fiber Sensors

Dimensions ■ Amplifier Units Amplifier Units with Cables E3X-MDA11 MDA41 CH1 CH2 E3X-MDA11 E3X-MDA41 Main display Sub-display Vinyl-insulated round cable Standard length: 2 m* *Cable Specifications A 4-dia., 2-conductor (conductor cross-sectional area: 0.2 mm2; insulation diameter: 1.1 mm) Second operation indicator First operation indicator 4.5 10 7 5.65 4.5 3.4 10 Two, 2.4 dia. 4.5 5.65 3.9 x 3 =11.7 12.15 15.1 32.8 3.25 29.8 3.9 x 3 = 11.7 4.3 70 32 12.5 9.9 16 3.4 4.4 34.8 28.1 16 28.1 16 18.7 44.3 Two, M3 The Mounting Bracket can also be used on this side. Holes for optical communications E39-L143 Mounting Bracket (order separately) (SUS304 stainless) Two, 3.2-dia. mounting holes Mounting Holes With Mounting Bracket Attached Four, 2.4 dia. E3X-DA@-S E3X-MDA@

E3X-MDA Super Dual Fiber Sensors

27 Amplifier Units with Connectors CH1 CH2 E3X-MDA6 E3X-MDA8 Main display Sub-display *1 The Mounting Bracket can also be used on this side. *2 Cable Diameters E3X-CN11 (3 conductors) E3X-CN21 (4 conductors) E3X-CN22 (2 conductors) 4.0-mm dia. E3X-CN12 (1 conductor) 2.6-mm dia. First operation indicator Second operation indicator 7 4.5 10 5.65 4.5 Four, 2.4 dia. 3.4 3.9 x 3 =11.75 12.15 15.1 32.8 3.25 29.8 3.9 x 3=11.7 4.3 70 8.1 32 12.95 9.9 16 34.8 28.1 18.7 44.3 Holes for optical communications 3.4 4.4 16 Two, M3 10 Two, 2.4 dia. 4.5 5.65 Connector Dia. A*2 16 28.1 *1 E39-L143 Mounting Bracket (order separately) (SUS304 stainless) Two, 3.2-dia. mounting holes Mounting Holes With Mounting Bracket Attached E3X-DA@-S E3X-MDA@

■ Amplifier Unit Connectors

Master Connectors Slave Connectors s 14.4 2.6 6 2.9 10 0.8 8.4 6.8 10.7 30±2 4 dia. 10±2 4 15.1 6 * *E3X-CN11: A 4-dia., 3-conductor, vinyl-insulated round cable (conductor cross- sectional area: 0.2 mm2; insulation diameter: 1.1 mm) is used. E3X-CN21: A 4-dia., 4-conductor, vinyl-insulated round cable (conductor cross- sectional area: 0.2 mm2; insulation diameter: 1.1 mm) is used. 2000 E3X-CN11 E3X-CN21 +50 0 50+5 0 14.4 2.6 3 6 2.9 10 0.8 8.4 6.8 10.7 2,000 50 30±2 E3X-CN12: 2.6 dia. E3X-CN22: 4 dia. 10±2 4 15.1 6 * +5 0 +50 0 E3X-CN12 E3X-CN22 *E3X-CN12: A 2.6-dia., single-conductor, vinyl-insulated round cable (conductor cross- sectional area: 0.2 mm2; insulation diameter: 1.1 mm) is used. E3X-CN22: A 4-dia., 2-conductor, vinyl-insulated round cable (conductor cross- sectional area: 0.2 mm2; insulation diameter: 1.1 mm) is used.

E3X-MDA Super Dual Fiber Sensors

29 ■ Mobile Console 136 50 52.8 22 Optical communications connection indicator Sensor operation indicator Main display Sub-display RIGHT key ESC/PWR key Operation keys ENT key LEFT key UP key DOWN key 20 28.8 13.2 31.2 9.9 27.7 17.3 1.2 5.1 12.3 36.7 51.3 5.6 24.3 30.3 31.8 16.3 13.1 (38.2) 10 AC adapter jack Communications jack Menu indicators Channel indicator M5 ball plunger Battery indicators Channel buttons Optical communi- cations position Communications jack E3X-MC11-S Mobile Console Mobile Console Head

OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if

specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product. At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PERFORMANCE DATA Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof. In the interest of product improvement, specifications are subject to change without notice. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. E340-E1-03A OMRON Corporation Industrial Automation Company Sensing Devices Division H.Q. Industrial Sensors Division Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7022/Fax: (81)75-344-7107 0707