Text of Omron NT2S-SF123B-E - Quick Start Manual
While writing this document, It is assumed that the user is well acquainted with the PLC
being used and with Windows based software usage, in general.
[Hereafter, in the manual, NT2S-SF123B-E will be referred to as NT2S C.]
Omron NT2S-SF123B-E - The NT2S C is intended to be used as a low cost Operator interface for PLCs which are rich in
program memory or data memory areas such as the Omron C Series PLCs.
The NT2S C has the following features:
Feature
NT2S C
Display
Backlit 2X16 LCD
LEDs
2
Keys
6
ASCII screens
32 characters
Embedded variables
16
Key definitions:
Each key is mapped from work bits I0201.00 to I0201.05. Every time a key is pressed, the
corresponding bit as shown in the tabl
The work bits I0200.00 to I0200.15 control the mode of operation of the unit as follows:
Work Bit
Function
I0200.00
Controls LED0
I0200.01
Controls LED1
I0200.02 &
I0200.03
Not used
I0200.04 to
I0200.07
Reserved for future use
I0200.08 &
00 : Screen mode
01 : Register mode
I0200.09
10 : Operator mode 11 : Invalid
I0200.10 &
Timeout to screen mode from Operator mode
I0200.11
00 : 10 seconds
01 : 20 seconds
10 : 30 s
Omron NT2S-SF123B-E - The unit displays 32 characters from the PLC memory.
These characters are taken from the PLC data registers.
The unit tracks register DM0020 ( the Offset register ) in the PLC. The number in DM0020 gives
the start address of the data register block which contains the characters to be displayed. For
example, if DM0020 has number 124 in it, the unit will read 16 registers from DM0124, i.e. from
DM0124 to DM0139 and display the corresponding chara
Omron NT2S-SF123B-E - Example 1: To display a static screen
Suppose the following screen needs to be displayed on the NT2S C :
Last Rinse Cycle
Water pump is on
To display this screen, do the following:
a.
Move number 200 in DM0020 since the screen text will be stored in DM0200 onwards.
b.
Move character string “Last Rinse Cycle” into 8 words from DM0200.
c.
In a similar manner, the characters “Water pump is on” can be embedded into 8 words
from DM0208. (i.e. from DM02
This will put the following data in the data words below:
Word ASCII Hex Word ASCII Hex
DM0200 La 4C61H DM0208 Wa 5761H
DM0201 st 7374H DM0209 te 7465H
DM0202 R 2052H DM0210 r 7220H
DM0203 in 696EH DM0211 pu 7075H
DM0204 se 7365H DM0212 mp 6D70H
DM0205 C 2043H DM0213 i 2069H
DM0206 yc 7963H DM0214 s 7320H
DM0207 le 6C65H DM0215 on 6F6EH
Embedding a variable in the screen
Suppose the following screen needs to be displayed :
Door: CLOSED
BAKETIME: 13.6s
Suppose the bake time is available in data word DM0100 and the oven status is given by bit
I001.00.
To display the above screen, do the following:
a.
Move number 200 in DM0020 since the screen will be stored in DM0200 onwards.
b. Move character string “Door:” into 2 words, i.e. DM0200 and DM0201.
c.
Move characters “OPEN�
In a similar manner, embed the characters “BAKETIME: ” into 5 words
from DM0208.
e.
NT2S C uses DM0000 to DM0011 registers for embedding data. Here we select
DM0003 to be used for embedding. So, move the data of DM0100 into DM0003 so that
embedding can be done.
f.
Put 03032E03H in words DM0213 and DM0214. The NT2S C will read data in DM0003
and embed in xx.x format.
g.
Move “s “ into DM0215. This command completes the screen by appending the �
Omron NT2S-SF123B-E - In the register mode, the operator can access all the registers and bits in the PLC.
By pressing the REG key, the operator can scroll through the register prefixes. By using the UP
or DOWN keys, the register numbers can be accessed. Data can be changed in the registers by
pressing the DATA key. The data field will blink to indicate that the unit is ready to accept new
data. At this time, the UP or DOWN keys can be used to edit data follo
Triggering screens :
As it can be seen from the above examples, there are two ways to display screens with NT2S C :
1. Keep all the message characters in the data memory ( the Omron PLCs have lot of data
registers which in most applications involving simple digital controls are not used anyway )
and simply change the offset register to display different screens.
The user can fill the data memory using the “data display editor” menu of the PLC programmi
Omron Other Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
F3S-TGR-SB-K C |
Guide: Omron F3S-TGR-SB-K C (Q3291B, Upd.07-09-2026) |
1 | 1023 | 195 | 07-09-2026 | |
E2EH-X |
Omron E2EH-X Manual (Datasheet), @L4527D |
2 | 1206 | 218 | 21-05-2026 | |
F3S-TGR-SB - |
User Guide: Omron F3S-TGR-SB - (8XW2W1, Upd.17-05-2026) |
10 | 926 | 204 | 17-05-2026 | |
E5EK |
Omron E5EK User Guide (Operation & user’s manual), @144VM2 |
176 | 1242 | 236 | 15-05-2026 |