©2004 Linear LLC. All Rights Reserved. 07/04

Door Station Connections This details the procedures necessary to enable the Communication features of the H560. These connections include. • Door Stations (H580/H581) Open House Door Station (H580 or H581) 4 Twisted- Pair Shielded Wire w/ Ground Return Page Level Adjustment Doorbell Level Adjustment NOTICES: THIS DEVICE COMPLIES WITH FCC PART 15 RULES AND REGULATIONS. OPERATIONS SUBJECT TO THE FOLLOWING TWO CONDITIONS:(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERPENCE THAT MAY CAUSE UNDESIRED OPERATION. THIS DIGITAL APPARATUS IS CERTIFIED TO COMPLY WITH THE LIMITS OF A CLASS B DIGITAL DEVICE PURSUANT TO PART 15 OF FCC RULES. SEE INSTRUCTIONAL MANUAL IF INTERFERENCE TO RADIO RECEPTION IS SUSPECTED. COMPLIES WITH FCC PART 68 FCC REGISTRATION NUMBER: 5J7USA-30852-MA-T RINGER EQUIVALENCE: 0.6B NO USER SERVICEABLE PARTS INSIDE REFER SERVICE TO OPEN HOUSE APPROVED SERVICE TECHNICIAN modelH560 Multi-Room Audio & Intercom System MADE IN CHINA P/N: 930019592 REV. A Linear LLC Carlsbad, CA 92009, USA www.openhousesystems.com ©2004 Linear Corporation, Carlsbad, CA, USA ® P/N 9900538 A ® INSTALLATION MANUAL H580/H581 Warranty Linear LLC warrants this product to be free from defects in material and workmanship for two years (2 years). The time period will be measured using the date code labeled on the product. Linear LLC is not responsible for damage to the product resulting from the buyer's improper handling, stocking or warehousing of the product. Any implied warranty arising from the sale of the product including implied warranties of merchantability and fitness for purpose are limited. Linear LLC shall not be responsible for any losses, damages or expenses, whether direct, consequential, or incidental arising from the use or the inability to use the product. Some states and countries do not allow limitations on how long an implied warranty lasts or the exclusion or limitation or incidental or consequential damages, so the above exclusions may not apply. The Linear LLC warranty gives specific legal rights in addition to other rights, which may exist and vary from state to state and country to country. The warranty is limited to repair or replacement of products returned, freight prepaid, to Linear LLC, there is NO PROVISION FOR LABOR COST OR OTHER REIMBURSEMENTS OF ANY KIND. 1. Failures due to product abuse, such as negligence, improper use, and electrical surge including damage from lightening, water damage or other damage due to natural disasters are not covered by the warranty. The most common form of product abuse is surge damage caused by lightening. 2. The warranty shall also be voided by any tampering with the date code, labels or other markings on the product. 3. Products that are damaged in transit to Linear LLC due to improper packaging or by the carrier (shipping company) will not be covered under the warranty. If the product was damaged or lost by the carrier, it is the sender's responsibility to create a claim against the carrier. 4. The user is responsible for all labor costs associated with removing, reinstalling and returning the product to Linear LLC. Linear LLC, at its option, will repair or replace the defective product. Replacements will be made from B-Stock, if an exact replacement is not available, Linear LLC, at it's option, will select the nearest equivalent product. The user is responsible for freight charges to Linear LLC. Linear LLC will return warranted repaired or replacements by UPS Ground or an equivalent service. A customer may pay the additional costs for second-day or next-day service. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-999-5225 for an RPA# and other important details.

©2004 Linear LLC. All Rights Reserved. 08/04

INSTALLATION MANUAL 1. Use 22/24 AWG, 8 conductor, 4 twisted pair shielded cable w/ drain between the H560 and the Door Station location(s). 2. Connect the Drain wire to SHLD/GND position on the H560. 3. Connect DB-/DB+, MIC-/MIC+, SPKR-/SPKR+, and L-/L+ (if applicable) as shown in the diagram below. 4. Test functions and make adjustments as shown below. Connecting an OpenHouse Door Station (H580/H581) to the H560 H580/H581 See Gaining Access to the H560 PC Board, in H560 Installation Manual INSTALLATION TIP: The Door Speaker and Door Microphone levels can be adjusted by repositioning 2 shunts on the H560's PC Board . To gain access to the shunts, the top cover of the H560 must be removed. Make sure you are fully grounded before removing cover or touching the PC Board. A wrist strap connected to an earth ground is recommended. Default shunt position is Hi. Move to opposite pins to lower levels. DOOR MICROPHONE J2 Lo Hi MIC Gain DOOR SPEAKER Lo Hi J4 DSPK Gain DB+ DB- L+ L- MIC+ MIC- SPKR+ SPKR- Drain Wire X No connection at Door Station. Cut at jacket. H580/H581 PC Board DB+ DB- To Button N.O. H581 ONLY COM H560 4 twisted-pair shielded wire with drain =Maintain Twisted Pair Electronic Door Latch Release Mechanism (not sold by Open House) Door Latch Power Supply Class 2 Low Voltage Output to 110VAC H582 Faceplate Doorbell ®

Other Door Manuals