Polycom ReadiManagerLX100 Release Note
Text of the manual
Release Notes Update
February 4, 2005
This document provides complementary or late-breaking information about the ReadiManager LX100 that
is not available in the documentation or online Help. Check the Polycom web site
(http://www.polycom.com) for the latest information.
Table of Contents
Client Requirements................................
All software versions are supported
VTX Software
VTX 1.30 software or greater
ViewStation Software
ViewStation, SP, SP384 6.0 software or greater
ViewStation FX/EX 5.0 software or greater
ViaVideo Software
ViaVideo 5.0 software or greater
iPower Software
iPower 5.0 software or greater
PathNavigator
ReadiManager LX100 will tolerate a nominal amount of network latency (less than 5000
milliseconds). Higher network latency between the ReadiManager LX100 server and the
managed nodes may cause status updates to be dropped or queries to fail.
Before installing ReadiManager LX100, consult with your IT administrator to verify that your LAN meets
the above r
When working in the ReadiManager LX100 Web View
•
If a user remains at one screen for some time without taking any action, the user’s session with
ReadiManager LX100 automatically times out. In this case, it may appear that ReadiManager
LX100 is not working. To continue work, close the browser and log on again.
•
If any unusual error messages appe
STATUS ILLEGAL EQ NAME LENGTH error. Changing the parameter to YES corrects the
reservation problem.
11. In some cases when configuring the LX100 for the first time, during the scheduling of a multipoint
conference involving an MCU, an error comes up indicating that cascading MCU is necessary.
This error comes up even though an MCU resource is available. A w