Polycom ReadiManagerLX100 Release Note

Text of the manual

Release Notes Update

February 4, 2005 This document provides complementary or late-breaking information about the ReadiManager LX100 that is not available in the documentation or online Help. Check the Polycom web site (http://www.polycom.com) for the latest information. Table of Contents Client Requirements................................

All software versions are supported

VTX Software ƒ VTX 1.30 software or greater ViewStation Software ƒ ViewStation, SP, SP384 6.0 software or greater ƒ ViewStation FX/EX 5.0 software or greater ViaVideo Software ƒ ViaVideo 5.0 software or greater iPower Software ƒ iPower 5.0 software or greater PathNavigator ƒ

ReadiManager LX100 will tolerate a nominal amount of network latency (less than 5000

milliseconds). Higher network latency between the ReadiManager LX100 server and the managed nodes may cause status updates to be dropped or queries to fail. Before installing ReadiManager LX100, consult with your IT administrator to verify that your LAN meets the above r

When working in the ReadiManager LX100 Web View

• If a user remains at one screen for some time without taking any action, the user’s session with ReadiManager LX100 automatically times out. In this case, it may appear that ReadiManager LX100 is not working. To continue work, close the browser and log on again. • If any unusual error messages appe

STATUS ILLEGAL EQ NAME LENGTH error. Changing the parameter to YES corrects the

reservation problem. 11. In some cases when configuring the LX100 for the first time, during the scheduling of a multipoint conference involving an MCU, an error comes up indicating that cascading MCU is necessary. This error comes up even though an MCU resource is available. A w

Other Other Manuals