PSC QS2500 Product Reference Manual
Text of the manual
959 Terry Street
Eugene, Oregon 97402
Telephone: (541) 683-5700
Fax: (541) 345-7140
Copyright ©2002 PSC Inc. An Unpublished Work - All rights reserved. No part of the contents of this documenta-
tion or the procedures described therein may be reproduced or transmitted in any form or by any means without
prior written permission of PSC Inc. or its wholly owned subsidiaries ("PSC"). Owners of PSC products are hereby
granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own
internal business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright
notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the docu-
mentation.
Should future revisions of this manual be published, you can acquire printed versions by contacting PSC Customer
Administration. Electronic versions will either be downloadable from the PSC web site (www.pscnet.com) or pro-
vided on appropriate media. If you visit our web site and would like to make comments or suggestions about this or
other PSC publications, please let us know via the “Contact PSC” page.
Disclaimer
Reasonable measures have been taken to ensure that the information included in this manual is complete and
accurate. However, PSC reserves the right to change any specification at any time without prior notice.
PSC is a registered trademark of PSC Inc. The PSC logo is a trademark of PSC. All other trademarks and trade
names referred to herein are property of their respective owners.
Patents
Manufactured under License from Intermec IP Corp. and covered by one or more of
the following United States patents:
3,991,299 • 4,282,425 • 4,570,057 • 4,766,300 • 4,877,949 • 4,894,523 • 4,970,379 •
5,019,699 • 5,021,642 • 5,038,024 • 5,081,343 • 5,095,197 • 5,144,119 • 5,144,121 •
5,182,441 • 5,187,355 • 5,187,356 • 5,216,233 • 5,218,191 • 5,233,172 • 5,258,606 •
5,288,985 • 5,308,966 • 5,414,251 • 5,541,419 • 5,550,364 • 5,659,431 • 5,684,290 •
5,764,798 • 5,777,310 • 5,786,583 • 5,798,509 • 5,811,777 • 5,818,027 • 5,837,987 •
5,841,121 • 5,854,478 • 5,902,987 • 5,936,224 • 5,987,192 • 6,012,640 • 6,016,960 •
6,018,597 • 6,039,252 • 6,064,763 • 6,097,839 • 6,128,414
Product Reference Guide
i
Installation ......................................................................................... 1
Keyboard Wedge .........................................................................................1
Wand Emulation .........................................................................................1
RS-232 ......................................................................................................1
USB ..........................................................................................................1
Programming the QS2500 ..................................................................... 2
Resetting the QS2500 ..................................................................................3
Interfaces ..................................................................................................3
Keyboard Wedge ...................................................................................3
Wand Emulation ....................................................................................6
RS-232 ................................................................................................7
Advanced Feature ..................................................................................8
Scan ....................................................................................................... 10
Beep/Tone/LED Settings ............................................................................ 13
Label Editing (includes Prefix/Suffix) ............................................................ 15
Symbology Settings ............................................................................20
UPC-A ..................................................................................................... 20
UPC-E ..................................................................................................... 22
EAN-13 .................................................................................................... 24
EAN-8 ..................................................................................................... 25
Code 39 ................................................................................................... 27
Interleaved 2 of 5 ..................................................................................... 30
Industrial 2 of 5 ........................................................................................ 31
Matrix 2 of 5 ............................................................................................ 32
Codabar ................................................................................................... 34
Code 128 ................................................................................................. 36
Code 93 ................................................................................................... 38
Code 11 ................................................................................................... 40
MSI/Plessey ............................................................................................. 41
UK/Plessey ............................................................................................... 43
Telepen ................................................................................................... 44
Standard 2 of 5 ........................................................................................ 46
Code 16K ................................................................................................. 47
PDF417 ................................................................................................... 48
Italian PharmaCode ................................................................................... 49
RSS Expanded .......................................................................................... 50
RSS Limited ............................................................................................. 51
RSS-14 .................................................................................................... 52
Appendix - Default Settings ..................................................................53
Appendix B - Bar Code Samples ............................................................55
Appendix C - ASCII Codes ....................................................................58
Appendix D - Parameter Setting List ......................................................60
Appendix E - Alphanumeric Characters ..................................................61
Product Reference Guide
1
Installation
Complete the following steps for the appropriate interface.
Keyboard Wedge
1.
Turn off the terminal or computer.
2.
Disconnect the keyboard cable from the back of the terminal or
computer.
3.
Connect the QS2500 to the terminal or computer using the
appropriate interface cable.
4.
Turn the terminal or computer back on.
Wand Emulation
1.
Turn off the terminal or computer.
2.
Connect the appropriate interface cable to the terminal or com-
puter.
3.
Turn the terminal or computer on.
RS-232
1.
Turn off the terminal or computer.
2.
Connect the interface cable and the external power supply (DC
adapter) shipped with your QS2500. If a power-off-terminal
(POT) cable is shipped, no external power supply is required.
3.
Secure the connector to the serial port on the back of the com-
puter or terminal by tightening the two screws.
4.
If required, plug the power supply into the power source.
5.
Turn the terminal or computer on.
USB
1.
Plug the USB cable into the terminal or computer.
NOTE
If the QS2500 does not operate, turn off the terminal or computer
immediately and check all connections. If necessary, go through the
above steps again.
Programming the QS2500
To program the QS2500, you must scan a series of programming bar
codes in the correct order. The inside back cover of this manual con-
tains a table of alphanumeric bar codes needed to program the various
options.
To program each option:
1.
Scan the Start Program bar code above the list of options (see
the table below).
2.
Enter the option mode by scanning the Option bar code.
3.
Find the alphanumeric entry for the option setting you want,
and scan the alphanumeric characters located in Appendix E.
4.
Scan the Finish bar code in Appendix E.
5.
Scan the Exit bar code.
Table 1. Interface Options
Start Program
Option Bar Code
Option
Alphanumeric Entry
Keyboard Wedge
00
RS-232
01
Wand Emulation
02
USB
03
Exit
$
$
NOTES
- An asterisk (*) in the table indicates the default setting.
- A software utility, Configurator Express, is also available for programming
and configuring the QS2500. Refer to the Readme file on the QS2500 prod-
uct CD for additional information.
Product Reference Guide
3
Resetting the QS2500
To return all QS2500 option settings to the factory defaults, scan the fol-
lowing three bar codes, in the order shown:
Interfaces
The QS2500 supports four interfaces, Keyboard Wedge, RS-232, Wand
Emulation and USB. The correct interface cable is included for the scan-
ner interface type you ordered.
Keyboard Wedge
As a keyboard interface, the QS2500 supports most popular PCs and
IBM terminals. The installation of the wedge is a fairly simple process
that doesn’t require any changes of software or hardware.
Keyboard Type: Select the keyboard type connector for your host com-
puter.
Keyboard Layout: The Keyboard Layout option supports many lan-
guages. For details about keyboard languages, please refer to your
operating system manual.
Keyboard Speed: You can change the output speed of the QS2500 to
match that of the host computer. Generally, set 00 or 01 for high
speed. If output characters of bar codes get lost, you may need to set a
slower speed.
Start Program
Default Value
Initialization
Option Bar Code
Option
Alphanumeric
Entry
Keyboard Type
IBM AT, PS/2
00*
Reserved
01 - 06
Keyboard Layout
USA
00*
Belgium
01
Danish
02
France
03
Germany
04
Italian
05
Portuguese
06
Spanish
07
Swedish
08
Switzerland
09
UK
10
Latin American
11
Japan
12
Keyboard Speed
0–8
(0 = high clock rate;
8 = low clock rate)
00–08
01*
Start Program
$
$
Exit
Product Reference Guide
5
Function Key: When this option is enabled, the QS2500 outputs bar code
ASCII values from 01hex to 1Fhex as function-key presses in your appli-
cation. See the table of ASCII codes In Appendix C on page 58.
Numeric Key: If your application accepts only keypad numeric code, use
setting 01 to make the QS2500 output code as numeric-keypad presses
when it reads digits. If you use setting 02, Caps Lock and output will
be independent.
Caps Lock: By selecting Caps Lock or No Caps Lock, the QS2500 can get
Caps Lock status.
Power-On Simulation: All PCs check the keyboard status during the
power-on selftest. It is recommended that you enable this function if
you are working without a keyboard installation. It simulates keyboard
timing and passes the keyboard status to the PC during power-on.
Intercharacter Delay: This delay is inserted after each data character
transmitted. If the transmission speed is too high, the system may not
be able to receive all characters. You may need to adjust the delay to
make the system work properly.
Block Transmission Delay: This is a delay timer between bar code data
outputs. The feature is used to transfer continually with shorter bar
code data or multifield scanning.
Option Bar Code
Option
Alphanumeric
Entry
Function Key
Disable
00*
Enable
01
Numeric Key
Alphabetic key
00*
Numeric keypad
only
01
Alt+Keypad
02
Caps Lock
Caps lock
00
No caps lock
01*
$
Start Program
Block Transmission Delay
0–99 (10 msec.)
00–99
10*
Option Bar Code
Option
Alphanumeric
Entry
Interface selection
Keyboard Wedge
00*
Wand Emulation
01
Bar/Space Polarity
Bar high/Space low
00*
Bar low/Space high
01
Idle Polarity
Idle low
00*
Idle high
01
Option Bar Code
Option
Alphanumeric
Entry
$
$
Exit
$
Start Program
Product Reference Guide
7
RS-232
CTS = Clear To Send (Hardware Signal)
RTS = Request To Send (Hardware Signal)
Xon = Transmit On (ASCII Code 11hex)
Xoff = Transmit Off (ASCII Code13hex)
ACK = Acknowledge (ACSII Code 06hex)
NAK = Not Acknowledge (ASCII Code 15hex)
Flow Control
None: The communication uses only TxD and RxD signals, with-
out regard for any hardware or software handshaking proto-
col.
RTS/CTS: If the QS2500 wants to send the bar code data to the host
computer, it will issue the RTS signal first, wait for the CTS sig-
nal from the host computer, and then perform the normal data
communication. If there is no replied CTS signal from the host
computer after the timeout (response delay) duration, the
QS2500 will issue five warning beeps.
Output Speed (pixels per
second)
660
00
1250
01
2500
02
5000
03*
10000
04
20000
05
Margin Delay (pixels)
15 (Default)
00–99 (x 10 pixels)
15*
00–99
Transmit Delay (Milliseconds)
30 (default)
00–99 (x 10 msec.)
30*
00–99
Option Bar Code
Option
Alphanumeric
Entry
$
$
Exit
Xon/Xoff: When the host computer is unable to accept data, it
sends an Xoff code to inform the QS2500 to suspend data trans-
mission and an Xon to continue.
ACK/NAK: When the ACK/NAK protocol is used, the QS2500
waits for an ACK (acknowledge) or NAK (not acknowledge)
from the host computer after data transmission. It then resends
the data in response to a NAK.
Intercharacter Delay: This is the delay time between outputs of data
character. It is the same as the intercharacter delay of the key-
board wedge.
Block Transmission Delay: This is the delay time between outputs of
bar code data. It is the same as the block transmission delay of
the keyboard wedge.
Response Delay: This delay is used for serial communication. It is
the amount of time the QS2500 waits for handshaking
acknowledgment from the host computer.
Advanced Feature
PSC Aux. Port: This configures the QS2500 flow control to connect
to the Auxiliary (AUX) port of some PSC omni-directional
scanners. The QS2500 will assert RTS high to signal the scanner
that data will be sent immediately after RTS is asserted. When
connecting to a PSC scanner aux. port, additional program-
ming is required to enable transmission of code IDs for all
symbologies to be scanned.
Mode B: This configures the RS-233 flow control to communicate
to some Wincor (SNI) terminals.
Product Reference Guide
9
Option Bar Code
Option
Alphanumeric
Entry
Flow Control
None
00*
RTS/CTS
01
Xon/Xoff
02
ACK/NAK
03
PSC Aux. Porta
04
Mode B
05
Intercharacter Delay
0–99 (msec.)
00–99
00*
Block Transmission Delay
0–99 (10 msec.)
00–99
00*
Response Delay
0–99 (100 msec.)
00–99
20*
Baud Rate
300 Baud
00
600 Baud
01
1200 Baud
02
2400 Baud
03
4800 Baud
04
9600 Baud
05*
19200 Baud
06
38400 Baud
07
$
Start Program
Good-read off: The trigger button must be pressed to activate scan-
ning. The light source of the QS2500 stops scanning when there
is a successful read or no code is decoded after the standby
duration has elapsed.
Momentary: The trigger button acts as a switch. Pressing the but-
ton activates scanning and releasing the button stops scanning.
Alternate: The trigger button acts as a toggle switch. Pressing the
button activates or stops scanning.
Timeout off: The trigger button must be pressed to activate scan-
ning, and the QS2500 stops scanning when no code is decoded
after the standby duration has elapsed.
Continue: The QS2500 always keeps reading, and it does not mat-
ter whether the trigger button is pressed or the standby dura-
tion has elapsed.
Parity
None
00*
Odd
01
Even
02
Data Bit
8 bits
00*
7 bits
01
Stop Bit
1 bit
00*
2 bits
01
a. Reading PDF417 through the Aux. Port is host dependent.
Option Bar Code
Option
Alphanumeric
Entry
$
$
Exit
Product Reference Guide
11
Test only: The QS2500 always keeps a constant reading, and same-
label reading is allowed without double confirmation. The fea-
ture can test the performance of the QS2500 for reading speed
and sensitivity.
Standby Duration: A timeout duration of 1 to 99 seconds can be set. It is
effective only when the CCD scanning mode is operated in timeout-off
mode and good-read off mode.
Same Bar Code Delay Time: If the bar code has been scanned twice, then
only the first bar code will be accepted.
Double Confirm: If this option is enabled, the QS2500 will require a sev-
eral successful decodings to confirm the bar code data. Larger settings
will make misreads less likely. If a double confirm is set, the multifield
scan function will be disabled.
Multifield Scan: The QS2500 can be read many sets of bar code data on
the same scanning line at the same time, even if they are different kinds
of bar code symbology.
Option Bar Code
Option
Alphanumeric
Entry
Scanning Mode
Good-read off
00
Momentary
01*
Alternate
02
Timeout off
03
Continue
04
Test only
05
Standby Duration
0–99 (sec.)
01–99
10*
Same Bar Code Delay Time
0–99 (10 msec.)
01–99
50*
Start Program
Global Minimum/Maximum Code Length: Global minimum and maximum
length can be set to qualify data entry. The length is defined as the
actual bar code data length to be sent. Labels with length exceeding
these limits will be rejected. Make sure that the minimum-length set-
ting is no greater than the maximum-length setting; otherwise, the
labels of the symbology will not be readable. In particular, you can set
the same value for both minimum and maximum lengths to force
decoding of only fixed-length bar codes. This setting has no effect on
certain symbologies of fixed length.
Inverted Image Scan: With this option enabled, the QS2500 will scan
black/white bar codes with a white/black background.
CTS Trigger: This operation enables an external device to control scan-
ning by applying an external trigger signal to the CTS input. When
active, this signal causes scanning to begin as the QS2500’s trigger is
depressed.
Visible Scan Field Indicator: This function allows a visible indicator to be
emitted when the trigger is pulled.
Double Confirm
0–99
(0 = no double con-
firm)
00–09
00*
Multifield Scan
Disable
00*
Enable
01
Option Bar Code
Option
Alphanumeric
Entry
$
$
Exit
NOTE
Set the minimum/maximum length if you have a special demand for
individual bar codes. Include the checksum digits if you want to set
global minimum/maximum code length.
Product Reference Guide
13
Beep/Tone/LED Settings
Power-On Alert: After power-on, the QS2500 will generate an alert signal
to indicate a successful self-test.
LED Control: After each successful bar code reading, the LED above the
QS2500 will light up.
Option Bar Code
Option
Alphanumeric
Entry
Global Minimum Code Length
0–63
00–63
04*
Global Maximum Code Length
0–63
00–63
63*
Inverted Image Scan
Disable
00*
Enable
01
CTS Trigger
Disable
00*
Enable
01
Visible Scan Field Indicator
Disable
00*
30 second
01
60 second
02
90 second
03
120 second
04
150 second
05
180 second
06
Continuous
07
Start Program
$
$
Exit
Beep Control: After each successful bar code reading, the QS2500 will
beep.
Beep Loudness/Beep-Tone Frequency/Beep-Tone Duration: You can adjust
the loudness, tone, and duration of the good-read beep.
Option Bar Code
Option
Alphanumeric
Entry
Power-On Alert
Disable
00
Enable
01*
LED Indication
Disable
00
Enable
01*
Buzzer Indication
Disable
00
Enable
01*
Beep Loudness
0–07
00–07
03*
Beep-Tone Frequency
0–99 (100Hz)
00–99
26*
Beep-Tone Duration
0–99 (10 msec.)
00–99
10*
Beep/Lamp Option 1:
Beep & LED after decode
Disable
00
Enable
01*
Beep/Lamp Option 2:
Beep & LED after data transmis-
sion
Disable
00
Enable
01
Start Program
Product Reference Guide
15
Label Editing (includes Prefix/Suffix)
Prefix Characters: Up to 22 ASCII characters may be sent before data.
Suffix Characters: Up to 22 ASCII characters may be sent after data.
Preamble/Postamble Characters: These characters are affixed to the data
automatically when each bar code is decoded.
Example: Add a prefix/suffix or preamble/postamble for all
symbologies. In this example, you can send a ‘$’
symbol as a prefix for all symbologies by com-
pleting the following steps:
1.Scan the Start Program and Prefix Characters
Setting bar codes below.
2.Use the ASCII code table (see Appendix C -
page 58) to find the ASCII value for $(24hex).
3.Scan the bar codes for 2 and 4 on the inside
back cover of this manual.
4.Scan the Finish bar code on the inside back
cover.
5.Scan the Exit bar code.
Insert G1/G2/G3/G4 Character Setting: The QS2500 offer four positions and
four characters to insert into the symbol data.
Example: Bar code: “1 2 3 4 5 6”.
Output: “1 2 A B 3 4 C D 5 6”.
Beep/Lamp Option 3:
Beep & LED after data transmis-
sion & CTS active
Disable
00
Enable
01
Option Bar Code
Option
Alphanumeric
Entry
Exit
Prefix
Data
Suffix
1.Scan Start Program and Insert G1 Characters
Setting bar code below.
2.Use the ASCII code table (see Appendix C on
page 58) to find the ASCII value for A (41) and
B (42).
3.Scan the hex digit bar codes for 4, 1 and 4, 2
on the inside back cover of this manual.
4.Scan the Finish bar code on the inside back
cover.
5.Repeat the same procedure for the G2 charac-
ters.
6.Scan the Exit bar code.
7.Insert the data group 1–4 position. (page 17.)
Option Bar Code
Option
Alphanumeric
Entry
Prefix
None
00*
1–22 characters
00–ffhex ASCII code
Suffix
None
00
1–22 characters
00–ffhex ASCII code
*
Preamble
None
00*
1–22 characters
00–ffhex ASCII code
Postamble
None
00*
1–22 characters
00–ffhex ASCII code
$
Start Program
Product Reference Guide
17
Preamble Transmission: The preamble will be appended before the code
data.
Postamble Transmission: The postamble will be appended after the code
data.
Insert Data Group 1–4 Position: The QS2500 offers four positions to insert
characters into the bar code data. The position default value of “00”
indicate no character insertion.
Insert G1 Characters Setting
None
00*
1–22 characters
00–ffhex ASCII code
Insert G2 Characters Setting
None
00*
1–22 characters
00–ffhex ASCII code
Insert G3 Characters Setting
None
00*
1–22 characters
00–ffhex ASCII code
Insert G4 Characters Setting
None
00*
1–22 characters
00–ffhex ASCII code
Option Bar Code
Option
Alphanumeric
Entry
Exit
NOTE
Make sure insertion positions are not greater than the number of bar
code characters; otherwise, the data will not be inserted.
Code ID Position: The code ID can be placed before or after the code data.
Code ID Transmission: Enable this option to transmit the code ID. See
page 20.
Code Length Transmission: A number of data digits can be transmitted
before the code data. The total length of the bar code is the number of
characters of bar code data without truncated leading or ending digits.
Option Bar Code
Option
Alphanumeric
Entry
Preamble Transmission
Disable
00*
Enable
01
Postamble Transmission
Disable
00*
Enable
01
Insert Data Group 1 Position
0–63
(0 = no insertion)
00*
00–63
1–22 characters
00–ffhex ASCII code
Insert Data Group 2 Position
0–63
(0 = no insertion)
00*
00–63
Insert Data Group 3 Position
0–63
(0 = no insertion)
00*
00–63
Insert Data Group 4 Position
0–63
(0 = no insertion)
00*
00–63
Code ID Position
Before code data
00*
After code data
01
$
Start Program
Exit
Product Reference Guide
19
Code Name Transmission: This function is used to show unknown bar
code symbologies that include all readable symbologies of the QS2500.
The code name will be transmitted before the bar code data to identify
the symbology.
Case Conversion: You can set the alpha characters to be displayed as
either uppercase or lowercase.
Order of transmission precedence:
Prefix
Code Name
Preamble
Code ID
Code Length
Bar Code Data
Code ID
Postamble
Suffix
Insert Groups
or
Option Bar Code
Option
Alphanumeric
Entry
Code ID Transmission
Disable
00*
Enable
01
Code Length Transmission
Disable
00*
Enable
01
Code Name Transmission
Disable
00*
Enable
01
Case Conversion
(for bar code alpha data only)
Disable
00*
Uppercase
01
Lowercase
02
Exit
Checksum Transmission: With this option enabled, the QS2500 will trans-
mit the checksum.
Truncate Leading/Ending: The leading or ending digits of bar code data
characters can be truncated. The QS2500 will beep instead of reading
anything when the truncate value is more than the bar code data digits
or the truncate leading value overlaps the truncate ending value.
Code ID Setting: The code ID is a character used to represent the bar code
type. The code ID is affixed to the beginning or end of the transmitted
data if the feature is selected. If you want your application to transmit
the code ID, you must set the code ID transmission option to 01 first.
See page 19.
Insertion Group Selection: The QS2500 offers one or two insertion groups
for a symbology. Set one or two digits to indicate which insertion group
you want to insert. See pages 15–17 for information about insertion
groups.
Examples: Group 2 ¤ set 02 or 20
Group 1 and 4 ¤ set 14 or 41
Supplement Digits: The supplement-digits bar code is the supplemental 2
or 5 characters for WPC code.
Format:
Truncate Leading Zero: The leading zeros in bar code data can be trun-
cated.
Examples: Bar code: “00054321”
Output: “54321”
Leading Zero
Data Digits (11 Digits)
Check Digit
Leading Zero
Data Digits (11 Digits)
Check Digit
Supplemental Digits
(2 or 5)
Product Reference Guide
21
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00
Enable
01*
Checksum Verification
Disable
00
Enable
01*
Checksum Transmission
Disable
00
Enable
01*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffhex ASCII code
00–ffhex*
Insertion Group Selection
0–44
00–44
00*
Supplement Digits
None
00*
2 digits
01
5 digits
02
UCC/EAN 128
03
Auto Detection
04
Truncate Leading Zero
Disable
00
Enable
01*
$
Start Program
$
$
Exit
Checksum Transmission: When this option is enabled, the QS2500 will
transmit the checksum.
Truncate Leading/Ending: Same as UPC-A. See page 20.
Code Id Setting: Same as UPC-A. See page 20.
Insertion Group Selection: Same as UPC-A. See page 20.
Supplement Digits: Format:
Truncate Leading Zero: Same as UPC-A. See page 20.
Expansion: The expansion function is used only for UPC-E and EAN-8
barcodes. It extends to 13 digits with zeros.
Example: Bar code: “0123654”
Output: “0012360000057”
Leading Zero
Data Digits (6 Digits)
Check Digits
Leading Zero
Data Digits (6 Digits)
Check Digit
Supplemental Digits
(2 or 5)
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00
Enable
01*
Checksum Verification
Disable
00
Enable
01*
$
Start Program
Product Reference Guide
23
Checksum Transmission
Disable
00
Enable
01*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffH ASCII code
00–ffhex*
Insertion Group Selection
0–44
00–44
00*
Supplement Digits
None
00*
2 digits
01
5 digits
02
UCC/EAN 128
03
Auto Detection
04
Truncate Leading Zero
Disable
00
Enable
01*
Expansion
Disable
00*
Enable
01
Option Bar Code
Option
Alphanumeric
Entry
$
$
Exit
Checksum Transmission: When this option is enabled, the QS2500 will
transmit the checksum.
Truncate Leading/Ending: Same as UPC-A. See page 20.
Code ID Setting: Same as UPC-A. See page 20.
Insertion Group Selection: Same as UPC-A. See page 20.
Supplement Digits: Format:
ISBN/ISSN: The ISBN (International Standard Book Number) and ISSN
(International Standard Serial Number) are two kinds of bar code for
books and magazines. The ISBN is ten digits, with a leading “978”, and
the ISSN is eight digits, with a leading “977”.
Examples: Bar code: “9789572222720”
Output: “9572222724”
Bar code: “9771019248004”
Output: “10192484”
Data Digits (12 Digits)
Check Digits
Data Digits
(6 Digits)
Check
Digits
Supplement
Digits 2 or 5
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00
Enable
01*
Checksum Verification
Disable
00
Enable
01*
$
Start Program
Product Reference Guide
25
EAN-8
Read: Format:
Checksum Transmission
Disable
00
Enable
01*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffH ASCII code
00–ffhex*
Insertion Group Selection
0–44
00–44
00*
Supplement Digits
None
00*
2 digits
01
5 digits
02
UCC/EAN 128
03
Auto Detection
04
ISBN/ISSN Conversion
Disable
00*
Enable
01
Option Bar Code
Option
Alphanumeric
Entry
$
$
Exit
Data Digits (7 Digits)
Check Digits
Checksum Transmission: When this option is enabled, the QS2500 will
transmit the checksum.
Truncate Leading/Ending: Same as UPC-A. See page 20.
Code ID Setting: Same as UPC-A. See page 20.
Insertion Group Selection: Same as UPC-A. See page 20.
Supplement Digits: Format:
Truncate Leading Zero: Same as UPC-A. See page 20.
Expansion: Same as UPC-E. See page 22.
Data Digits (7 Digits)
Check Digits
Supplement Digits (2 or 5)
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00
Enable
01*
Checksum Verification
Disable
00
Enable
01*
Checksum Transmission
Disable
00
Enable
01*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
Two characters
00–ffhex ASCII code
00–ffhex*
$
Start Program
Product Reference Guide
27
Code 39
Read: Format:
Checksum Verification: The checksum is optional and presented as the
sum mod 43 of the numerical value of the data digits.
Checksum Transmission: When this option is enabled, the QS2500 will
transmit the checksum.
Insertion Group Selection
0–44
00–44
00*
Supplement Digits
None
00*
2 digits
01
5 digits
02
UCC/EAN 128
03
Auto Detection
04
Truncate Leading Zero
Disable
00*
Enable
01
Expansion
Disable
00*
Enable
01
Option Bar Code
Option
Alphanumeric
Entry
Exit
Start “*”
Data Digits (Variable)
Checksum (Optional)
End “*”
Maximum/Minimum Code Length: Each symbology has own maximum and
minimum code length, which can be set to qualify data entry. The
length is defined as the actual bar code data length to be sent. Labels
with lengths below the minimum or above the maximum will be
rejected. If the maximum and minimum code lengths are both set to
zero, the global minimum and maximum code length settings are in
effect.
Truncate Leading/Ending: Same as UPC-A. See page 20.
Code ID Setting: Same as UPC-A. See page 20.
Insertion Group Selection: Same as UPC-A. See page 20.
Format: The Full ASCII Code 39, an enhanced set of Code 39, uses a
total of 128 characters to represent Full ASCII code. Each Full ASCII
Code 39 character is a combination of one of the characters +,%, $ and /
with an uppercase alphabetical character (A to Z).
Append: This function allows several symbols to be concatenated and
be treated as a single entry. The QS2500 will not transmit the embedded
appending code (for Code-39, a space). If the append function is
enabled and other symbols are read again with the appended code,
then the codes are transmitted without the code ID, preamble, or pre-
fix. When a symbol was decoded without the appended code, the data
is transmitted without the code ID and prefix, but the postamble suffix
codes are appended. This function is used when the first character of
Code 39 data is a space.
Start/End Transmission: The start and end characters of Code 39 are aster-
isks (*). You can transmit all data digits, including the two asterisks.
NOTE
Make sure that the minimum length setting is not greater than the max-
imum length setting; otherwise, all the labels of the symbology will be
unreadable. You can set the same value for both minimum and maxi-
mum length to force decoding of only bar codes of a certain length.
Product Reference Guide
29
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00
Enable
01*
Checksum Verification
Disable
00*
Enable
01
Checksum Transmission
Disable
00*
Enable
01
Maximum Code Length
0–64
00–64
00*
Minimum Code Length
0–64
00–64
00*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffhex ASCII code
00–ffhex<*>
Insertion Group Selection
0–44
00–44
00*
Format
Standard ASCII
00*
Full ASCII
01
Append
Disable
00*
Enable
01
Start/End Transmission
Disable
00*
Enable
01
$
Start Program
$
$
Exit
Interleaved 2 of 5
Read: Format:
Checksum Verification: The checksum is presented as the sum mod 10 of
the numerical values of all data digits.
Checksum Transmission: When this option is enabled, the QS2500 will
transmit the checksum.
Maximum/Minimum Code Length: Same as Code 39. See page 28.
Truncate Leading/Ending: Same as UPC-A. See page 20.
Code ID Setting: Same as UPC-A. See page 20.
Insertion Group Selection: Same as UPC-A. See page 20.
Data Digits (Variable)
Checksum (Optional)
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00
Enable
01*
Checksum Verification
Disable
00
Enable
01*
Checksum Transmission
Disable
00*
Enable
01
Maximum Code Length
0–64
00–64
00*
Minimum Code Length
0–64
00–64
00*
$
Start Program
Product Reference Guide
31
Industrial 2 of 5
Read: Format:
Maximum/Minimum Code Length: Same as Code 39. See page 28.
Truncate Leading/Ending: Same as UPC-A. See page 20.
Code ID Setting: Same as UPC-A. See page 20.
Insertion Group Selection: Same as UPC-A. See page 20.
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffhex ASCII code
00–ffhex*
Insertion Group Selection
0–44
00–44
00*
Option Bar Code
Option
Alphanumeric
Entry
$
$
Exit
Data Digits (Variable)
Checksum (Optional)
Matrix 2 of 5
Read: Format:
Checksum Verification: The checksum is presented as the sum mod 10 of
the numerical values of all data digits.
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00*
Enable
01
Maximum Code Length
0–64
00–64
00*
Minimum Code Length
0–64
00–64
00*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffhex ASCII code
00–ffhex*
Insertion Group Selection
0–44
00–44
00*
$
Start Program
Exit
Data Digits (Variable)
Checksum (Optional)
Product Reference Guide
33
Checksum Transmission: When this option is enabled, the QS2500 will
transmit the checksum.
Maximum/Minimum Code Length: Same as Code 39. See page 28.
Truncate Leading/Ending: Same as UPC-A. See page 20.
Code ID Setting: Same as UPC-A. See page 20.
Insertion Group Selection: Same as UPC-A. See page 20.
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00*
Enable
01
Checksum Verification
Disable
00*
Enable
01
Checksum Transmission
Disable
00*
Enable
01
Maximum Code Length
0–64
00–64
00*
Minimum Code Length
0–64
00–64
00*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
$
Start Program
Checksum Verification: The checksum is presented as the sum mod 16 of
the numerical values of all data digits.
Checksum Transmission: When this option is enabled, the QS2500 will
transmit the checksum.
Maximum/Minimum Code Length: Same as Code 39. See page 28.
Truncate Leading/Ending: Same as UPC-A. See page 20.
Code ID Setting: Same as UPC-A. See page 20.
Insertion Group Selection: Same as UPC-A. See page 20.
Start/End Type: Codabar has four pairs of Start/End patterns. Select one
pair to match your application.
Start/End Transmission: Same as Code 39. See page 28.
Code ID Setting
00–ffhex ASCII code
00–ffhex*
Insertion Group Selection
0–44
00–44
00*
Option Bar Code
Option
Alphanumeric
Entry
$
$
Exit
Start
Data Digits (Variable)
Checksum (Optional)
End
Product Reference Guide
35
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00*
Enable
01
Checksum Verification
Disable
00*
Enable
01
Checksum Transmission
Disable
00*
Enable
01
Maximum Code Length
64–Minimum
64–00
00*
Minimum Code Length
0–Maximum
00–64
00*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffhex ASCII code
00–ffhex<%>*
Insertion Group Selection
0–44
00–44
00*
Start/End Type
ABCD/ABCD
00*
abcd/abcd
01
ABCD/TN*E
02
abcd/tn*e
03
$
Start Program
Checksum Verification: The checksum is presented as the sum mod 103 of
all data digits.
Checksum Transmission: When this option is enabled, the QS2500 will
transmit the checksum.
Maximum/Minimum Code Length: Same as Code 39. See page 28.
Truncate Leading/Ending: Same as UPC-A. See page 20.
Code ID Setting: Same as UPC-A. See page 20.
Insertion Group Selection: Same as UPC-A. See page 20.
Format: The Code 128 data string can be translated to UCC/EAN-128
format if it starts with “FNC1”. The first “FNC1” will be translated to
“]C1”, and the second “FNC1” to a concatenation code “(1Dhex)”.
Append: When the function is enabled, it won't show the data immedi-
ately if scanner read the barcode includes FNC2 code. It will show all
data until it read a barcode, which doesn't have FNC2 code.
Start/End Transmission
Disable
00*
Enable
01
Option Bar Code
Option
Alphanumeric
Entry
$
$
Exit
Data Digits (Variable)
Checksum (Optional)
]C1
Data
Data
Checksum
]C2
Data
Data
Checksum
Product Reference Guide
37
Concatenation Code: This feature is only used for UCC/EAN-128. The
Concatenation Code is the separator character, default is (1Dhex),
inserted between characters when label data is concatenated and
treated as a single entry. For example:
•
UCC/EAN-128 Structure:
Checksum Verification: The checksum is presented as the sum mod 47 of
the numerical values of all data digits.
Checksum Transmission: When this option is enabled, the QS2500 will
transmit the checksum.
Maximum/Minimum Code Length: Same as Code 39. See page 28.
Truncate Leading/Ending: Same as UPC-A. See page 20.
Code ID Setting: Same as UPC-A. See page 20.
Insertion Group Selection: Same as UPC-A. See page 20.
Insertion Group Selection
0–44
00–44
00*
Format
Standard
00*
UCC/EAN-128
01
Append
Disable
00*
Enable
01
UCC/EAN-128ID Setting
00–ffhex ASCII code
00–ffhex<#>*
Concatenation Code
00–ffhex ASCII code
00–ffhex1Dhex*
Option Bar Code
Option
Alphanumeric
Entry
$
$
Exit
Data Digits (Variable)
Checksum1 (Optional)
Checksum1 (Optional)
Product Reference Guide
39
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00*
Enable
01
Checksum Verification
Disable
00
Enable (two digits)
01*
Checksum Transmission
Disable
00*
Enable
01
Maximum Code Length
64–Minimum
64–00
00*
Minimum Code Length
0–Maximum
00–64
00*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffhex ASCII code
00–ffhex<&>*
Insertion Group Selection
0–44
00–44
00*
$
Start Program
Exit
Checksum Verification: The checksum is presented as the sum mod 11 of
all data digits.
Checksum Transmission: When this option is enabled, the QS2500 will
transmit one-digit or two-digit checksums, depending upon the setting
for checksum verification.
Maximum/Minimum Code Length: Same as Code 39. See page 28.
Truncate Leading/Ending: Same as UPC-A. See page 20.
Code ID Setting: Same as UPC-A. See page 20.
Insertion Group Selection: Same as UPC-A. See page 20.
Data Digits
(Variable)
Checksum1
(Optional)
Checksum1
(Optional)
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00*
Enable
01
Checksum Verification
Disable
00
One digit
01*
Two digit
02
Checksum Transmission
Disable
00*
Enable
01
Maximum Code Length
64–Minimum
64–00
00*
Start Program
Product Reference Guide
41
MSI/Plessey
Read: Format:
Checksum Verification: The MSI/Plessey code has one or two optional
checksum digits. The checksums are calculated as the sum mod 10 or
11 of the data digits.
Checksum Transmission: When this option is enabled, the QS2500 will
transmit one-digit or two-digit checksums, depending upon the setting
for checksum verification.
Maximum/Minimum Code Length: Same as Code 39. See page 28.
Truncate Leading/Ending: Same as UPC-A. See page 20.
Code ID Setting: Same as UPC-A. See page 20.
Minimum Code Length
0–Maximum
00–64
00*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffhex ASCII code
00–ffhex*
Insertion Group Selection
0–44
00–44
00*
Option Bar Code
Option
Alphanumeric
Entry
Exit
Data Digits (Variable)
Checksum1 (Optional)
Checksum2 (Optional)
Insertion Group Selection: Same as UPC-A. See page 20.
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00*
Enable
01
Checksum Verification
Disable
00*
Mod 10
01
Mod 10/10
02
Mod 11/10
03
Checksum Transmission
Disable
00*
Enable
01
Maximum Code Length
64–Minimum
64–00
00*
Minimum Code Length
0–Maximum
00–64
00*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
$
Start Program
Product Reference Guide
43
UK/Plessey
Read: Format:
Checksum Verification: The UK/Plessey code has one or two optional
checksum digits. The checksums are calculated as the sum mod 10 or
11 of the data digits.
Checksum Transmission: When this option is enabled, the QS2500 will
transmit the checksum.
Maximum/Minimum Code Length: Same as Code 39. See page 28.
Truncate Leading/Ending: Same as UPC-A. See page 20.
Code ID Setting: Same as UPC-A. See page 20.
Insertion Group Selection: Same as UPC-A. See page 20.
Code ID Setting
00–ffhex ASCII code
00–ffhex<@>*
Insertion Group Selection
0–44
00–44
00*
Option Bar Code
Option
Alphanumeric
Entry
Exit
Data Digits (Variable)
Checksum1+2 (Optional)
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00*
Enable
01
Checksum Verification
Disable
00
Enable
01*
Checksum Transmission
Disable
00*
Enable
01
Maximum Code Length
64–Minimum
64–00
00*
Minimum Code Length
0–Maximum
00–64
00*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffhex ASCII code
00–ffhex<@>*
Insertion Group Selection
0–44
00–44
00*
Start Program
Exit
Product Reference Guide
45
Telepen
Read: Format:
Checksum Verification: The checksum is presented as the sum mod 10 or
11 of the data digits.
Checksum Transmission:
When this option is enabled, the QS2500 will transmit the checksum.
Maximum/Minimum Code Length: Same as Code 39. See page 28.
Truncate Leading/Ending: Same as UPC-A. See page 20.
Code ID Setting: Same as UPC-A. See page 20.
Insertion Group Selection: Same as UPC-A. See page 20.
Format: Numeric data only. Full ASCII data.
Data Digits
Checksum1 (Optional)
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00*
Enable
01
Checksum Verification
Disable
00*
Enable
01
Checksum Transmission
Disable
00*
Enable
01
Maximum Code Length
64–Minimum
64–00
00*
$
Start Program
Standard 2 of 5
Read: Format
Maximum/Minimum Code Length: Same as Code 39. See page 28.
Truncate Leading/Ending: Same as UPC-A. See page 20.
Code ID Setting: Same as UPC-A. See page 20.
Insertion Group Selection: Same as UPC-A. See page 20.
Minimum Code Length
0–Maximum
00–64
00*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffhex ASCII code
00–ffhex*
Insertion Group Selection
0–44
00–44
00*
Format
Numeric only
00*
Full ASCII only
01
Option Bar Code
Option
Alphanumeric
Entry
Exit
Data Digits
(Variable)
Checksum1
(Optional)
Product Reference Guide
47
Code 16K
Truncate Leading/Ending: Same as UPC-A. See page 20.
Code ID Setting: Same as UPC-A. See page 20.
Insertion Group Selection: Same as UPC-A. See page 20.
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00*
Enable
01
Maximum Code Length
64–Minimum
64–00
00*
Minimum Code Length
0–Maximum
00–64
00*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffhex ASCII code
00–ffhex
Insertion Group Selection
0–44
00–44
00*
$
Start Program
Exit
Truncate leading/ending: Same as UPC-A. See page 20.
Code ID Setting: Same as UPC-A. See page 20.
Insertion Group Selection: Same as UPC-A. See page 20.
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00*
Enable
01
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffhex ASCII code
00–ffhex<>
Insertion Group Selection
0–44
00–44
00*
$
Start Program
Exit
Product Reference Guide
49
Italian PharmaCode
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00
Enable
01*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffhex ASCII code
00–ffhex<>
Insertion Group Selection
0–44
00–44
00*
$
Start Program
Exit
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00*
Enable
01
Maximum Code Length
64–Minimum
64–00
10*
$
Start Program
Minimum Code Length
0–Maximum
00–64
09*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffhex ASCII code
00–ffhex
Insertion Group Selection 0–44 00–44 00* Leading “A” Disable 00* Enable 01 Option Bar Code Option Alphanumeric Entry Exit Option Bar Code Option Alphanumeric Entry Read Disable 00* Enable 01 Maximum Code Length 64–Minimum 64–00 64* $ Start Program
Product Reference Guide
51
RSS Limited
Minimum Code Length
0–Maximum
00–64
01*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffhex ASCII code
00–ffhex
Insertion Group Selection
0–44
00–44
00*
UCC/EAN 128 Emulation
Disable
00*
Enable
01
Option Bar Code
Option
Alphanumeric
Entry
Exit
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00*
Enable
01S
Maximum Code Length
64–Minimum
64–00
64*
$
Start Program
Minimum Code Length
0–Maximum
00–64
01*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffhex ASCII code
00–ffhex
Insertion Group Selection
0–44
00–44
00*
UCC/EAN 128 Emulation
Disable
00*
Enable
01
Option Bar Code
Option
Alphanumeric
Entry
Exit
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
00*
Enable
01
Maximum Code Length
64–Minimum
64–00
64*
$
Start Program
Product Reference Guide
53
Appendix - Default Settings
Minimum Code Length
0–Maximum
00–64
01*
Truncate Leading
0–15
00–15
00*
Truncate Ending
0–15
00–15
00*
Code ID Setting
00–ffhex ASCII code
00–ffhex
Insertion Group Selection
0–44
00–44
00*
UCC/EAN 128 Emulation
Disable
00*
Enable
01
Option Bar Code
Option
Alphanumeric
Entry
Exit
Code Type
Read
Enable
Checksum
Verification
Enable
Checksum
Transmission
Enable
Code
ID
UPC-A
A
UPC-E
E
EAN-13
F
EAN-8
FF
Code 39
*
Interleaved 2 of 5
i
Industrial 2 of 5
i
Matrix 2 of 5
B
Codabar
%
Code 128
#
Code 93
&
Code 11
One digit
O
MSI/Plessey
One digit
@
UK/Plessey
@
Telepen
S
Standard 2 of 5
-
i
Code 16K
-
PDF417
-
Italian Pharma-
Code
p
RSS Expanded
RX
RSS Limited
RL
RSS-14
R4
Code Type
Read
Enable
Checksum
Verification
Enable
Checksum
Transmission
Enable
Code
ID
Product Reference Guide
55
Appendix B - Bar Code Samples
UPC-A
---------
UPC-E
---------
EAN-13
---------
EAN-8
---------
Code 39
---------
XZV
Interleaved 2 of 5
---------
Industrial 2 of 5
---------
1 23456 78901 2
0 1 2 3 4 5 6 5
1 234567 890128
1234 5670
*
1
2
3
4
5
6
7
*
0 1 2 3 4 5 6 7
0
1
2
4
3
4
5
Matrix 2 of 5
---------
Codabar
---------
Code 128
---------
Code 93
---------
Code 11
---------
MSI/Plessey
---------
UK/Plessey
---------
Standard 2 of 5
---------
Code 16K
---------
A 1 1 2 + B
A
1
2
3
4
5
B
c
d
B 6 7 8 9 0 B c d
6
7
8
9
0
1
2
3
6
7
8
9
0
1
2
3
Product Reference Guide
57
PDF417
---------
Italian PharmaCode
---------
RSS Expanded
---------
RSS Limited
---------
RSS-14
---------
Appendix C - ASCII Codes
0
1
0
1
0
Null
NUL
DLE
1
Up
F1
SOH
DC1
2
Down
F2
STX
DC2
3
Left
F3
ETX
DC3
4
Right
F4
EOT
DC4
5
PgUp
F5
ENQ
NAK
6
PgDn
F6
ACK
SYN
7
F7
BEL
ETB
8
Bs
F8
BS
CAN
9
Tab
F9
HT
EM
A
F10
LF
SUB
B
Home
Esc
VT
ESC
C
End
F11
FF
FS
D
Enter
F12
CR
GS
E
Insert
Ctrl+
SO
RS
F
Delete
Alt+
SI
US
= for keyboard wedge only
L
H
Product Reference Guide
59
2
3
4
5
6
7
0
SP
0
@
P
`
p
1
!
1
A
Q
a
q
2
“
2
B
R
b
r
3
#
3
C
S
c
s
4
$
4
D
T
d
t
5
%
5
E
U
e
u
6
&
6
F
V
f
v
7
‘
7
G
W
g
w
8
(
8
H
X
h
x
9
)
9
I
Y
i
y
A
:
J
Z
j
z
B
+
;
K
[
k
C
<
L
l
D
-
=
M
]
m
E
.
>
N
^
n
F
/
?
O
_
o
DEL
Example: ASCII “A” = “41”
L
H
Appendix D - Parameter Setting List
Start Program
Standard Parameter Setting List
If you wish to display the current configuration of your QS2500 over the host
terminal/computer, scan the Bar Code standard parameter setting list bar
code.
System Parameter Setting List
If you wish to display the product information and revision number for your
QS2500 over the host terminal/computer, scan the System parameter set-
ting list bar code.
String Setting List
If you wish to display the current configuration of your QS2500 over the host
terminal/computer, scan the Bar Code standard parameter setting list bar
code.
Unique Parameter List
If you wish to display the unique parameter setting list, scan the Unique
parameter list bar code.
Firmware Version List
If you wish to display the firmware version, scan the Firmware version list.
Exit
/
S
Q
Product Reference Guide
61
Appendix E - Alphanumeric Characters
0
A
1
B
2
C
3
D
4
E
5
F
6
Finish
7
8
9
Exit
DECLARATION OF CONFORMITY
PSC hereby declares that the Equipment specified below has been tested and found compliant to the
following Directives and Standards:
Al Eckerdt
Director, Corporate Quality
PSC, Inc.
959 Terry Street
Eugene, OR 97402
U.S.A.
Peter Lomax
Vice President
Europe, Middle East & Africa
PSC Bar Code Ltd.
Axis 3, Rhodes Way
Watford
Hertfordshire WD24 4TR
UK
Directives:
EMC 89/336/EEC
Low Voltage 73/23/EEC
Standards:
CISPR 22-A:1997 - Generic Emissions
EN 55022-A:1998 - Generic Emissions
EN 55024:1998 - Generic ITE Immunity
EN 60825-1:1998 - LED Safety
IEC 60950:1996 - ITE Safety
EN 61000-3-2 - Harmonic Current Emissions
EN 61000-3-3 - Voltage Fluctuation/Flicker
Equipment Type:
Linear Imager Handheld Barcode Scanner
Product:
QS25xx
PSC Hong Kong
Hong Kong
Telephone: [852]-2-584-6210
Fax: [852]-2-521-0291
Australia
PSC Asia Pacific Pty Ltd.
North Ryde, Australia
Telephone: [61] 0 (2) 9878 8999
Fax: [61] 0 (2) 9878 8688
France
PSC S.A.R.L.
LES ULIS Cedex, France
Telephone: [33].01.64.86.71.00
Fax: [33].01.64 46.72.44
Germany
PSC GmbH
Darmstadt, Germany
Telephone: 49 (0) 61 51/93 58-0
Fax: 49 (0) 61 51/93 58 58
Italy
PSC S.p.A.
Vimercate (MI), Italy
Telephone: [39] (0) 39/62903.1
Fax: [39] (0) 39/6859496
Japan
PSC Japan K.K.
Shinagawa-ku, Tokyo, Japan
Telephone: 81 (0)3 3491 6761
Fax: 81 (0)3 3491 6656
Latin America
PSC S.A., INC.
Miami, Florida, USA
Telephone: (305) 539-0111
Fax: (305) 539-0206
United Kingdom
PSC Bar Code Ltd.
Watford, England
Telephone: 44 (0) 1923 809500
Fax: 44 (0) 1923 809 505
Corp. Headquarters
PSC Inc.
Portland, OR
Telephone: (503) 553-3920
Fax: (503) 553-3940
PSC Inc.
959 Terry Street
Eugene, OR
Telephone: (541) 683-5700
Fax: (541) 345-7140
Printed on recycled paper
www.pscnet.com
©2003 PSC INC.
R44-2303 (Rev C)
(01/03)