Symbol LS3400 Product Reference Manual
Text of the manual
© 2006 by Symbol Technologies, Inc. All rights reserved.
No part of this publication may be reproduced or used in any form, or by any electrical or mechanical means, without
permission in writing from Symbol. This includes electronic or mechanical means, such as photocopying, recording, or
information storage and retrieval systems. The material in this manual is subject to change without notice.
The software is provided strictly on an “as is” basis. All software, including firmware, furnished to the user is on a
licensed basis. Symbol grants to the user a non-transferable and non-exclusive license to use each software or
firmware program delivered hereunder (licensed program). Except as noted below, such license may not be assigned,
sublicensed, or otherwise transferred by the user without prior written consent of Symbol. No right to copy a licensed
program in whole or in part is granted, except as permitted under copyright law. The user shall not modify, merge, or
incorporate any form or portion of a licensed program with other program material, create a derivative work from a
licensed program, or use a licensed program in a network without written permission from Symbol. The user agrees to
maintain Symbol’s copyright notice on the licensed programs delivered hereunder, and to include the same on any
authorized copies it makes, in whole or in part. The user agrees not to decompile, disassemble, decode, or reverse
engineer any licensed program delivered to the user or any portion thereof.
Symbol reserves the right to make changes to any software or product to improve reliability, function, or design.
Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product,
circuit, or application described herein.
No license is granted, either expressly or by implication, estoppel, or otherwise under any Symbol Technologies, Inc.,
intellectual property rights. An implied license only exists for equipment, circuits, and subsystems contained in Symbol
products.
Symbol, Spectrum One, and Spectrum24 are registered trademarks of Symbol Technologies, Inc. Bluetooth is a
registered trademark of Bluetooth SIG. Microsoft, Windows and ActiveSync are either registered trademarks or
trademarks of Microsoft Corporation. Other product names mentioned in this manual may be trademarks or registered
trademarks of their respective companies and are hereby acknowledged.
Symbol Technologies, Inc.
One Symbol Plaza
Holtsville, New York 11742-1300
http://www.symbol.com
Patents
This product is covered by one or more of the patents listed on the website: www.symbol.com/patents.
Changes to the original manual are listed below:
Change
Date
Description
Rev A
7/2006
Initial release
Table of Contents
About This Guide
Overview ....................................................................................................................... ix
Chapter Descriptions..................................................................................................... ix
Notational Conventions................................................................................................. x
Related Documents....................................................................................................... x
Service Information ....................................................................................................... xi
Chapter 1: Getting Started
Introduction .................................................................................................................. 1-1
Unpacking the Scanner ................................................................................................ 1-1
Setting Up the Scanner ................................................................................................ 1-2
Installing the Interface Cable .................................................................................. 1-2
Connecting Power (if required) .............................................................................. 1-3
Removing the Interface Cable ................................................................................ 1-3
Configuring the Scanner ........................................................................................ 1-3
Chapter 2: Scanning
Introduction .................................................................................................................. 2-1
Beeper Definitions ........................................................................................................ 2-2
LED Definitions ............................................................................................................ 2-2
Scanning in Hand-Held Mode ...................................................................................... 2-3
Aiming .................................................................................................................... 2-4
Decode Zone ................................................................................................................ 2-5
Chapter 3: Maintenance, Troubleshooting, & Specifications
Introduction .................................................................................................................. 3-1
Maintenance ................................................................................................................. 3-1
Troubleshooting ........................................................................................................... 3-2
Technical Specifications ............................................................................................... 3-3
Scanner Signal Descriptions ........................................................................................ 3-5
Chapter 4: User Preferences
Introduction .................................................................................................................. 4-1
LS3400 Product Reference Guide
Scanning Sequence Examples ..................................................................................... 4-1
Errors While Scanning .................................................................................................. 4-1
User Preferences Default Parameters .......................................................................... 4-2
User Preferences .......................................................................................................... 4-3
Set Default Parameter ............................................................................................. 4-3
Beeper Tone ........................................................................................................... 4-3
Beeper Volume ....................................................................................................... 4-4
Power Mode ............................................................................................................ 4-4
Laser On Time ........................................................................................................ 4-5
Beep After Good Decode ........................................................................................ 4-6
Trigger Mode ........................................................................................................... 4-6
Aim Duration ........................................................................................................... 4-7
Chapter 5: Scanner Emulation Interface
Introduction ................................................................................................................... 5-1
Connecting Using Scanner Emulation .......................................................................... 5-2
Scanner Emulation Default Parameters ........................................................................ 5-3
Scanner Emulation Host Parameters ............................................................................ 5-4
Convert Newer Code Types .................................................................................... 5-4
Module Width .......................................................................................................... 5-4
Convert All Bar Codes to Code 39 .......................................................................... 5-5
Code 39 Full ASCII Conversion .............................................................................. 5-5
Transmission Timeout ............................................................................................. 5-6
Transmit With Unknown Characters ....................................................................... 5-7
Leading Margin ....................................................................................................... 5-8
Chapter 6: Symbologies
Introduction ................................................................................................................... 6-1
Scanning Sequence Examples ..................................................................................... 6-1
Errors While Scanning .................................................................................................. 6-1
Symbology Default Parameters .................................................................................... 6-2
UPC/EAN ...................................................................................................................... 6-5
Enable/Disable UPC-A ............................................................................................ 6-5
Enable/Disable UPC-E ............................................................................................ 6-5
Enable/Disable UPC-E1 .......................................................................................... 6-6
Enable/Disable EAN-13 .......................................................................................... 6-6
Enable/Disable EAN-8 ............................................................................................ 6-7
Enable/Disable Bookland EAN ................................................................................ 6-7
Decode UPC/EAN/JAN Supplementals .................................................................. 6-8
UPC/EAN/JAN Supplemental Redundancy ............................................................ 6-10
Transmit UPC-A/UPC-E/UPC-E1 Check Digit ........................................................ 6-10
UPC-A Preamble ..................................................................................................... 6-12
UPC-E Preamble ..................................................................................................... 6-13
UPC-E1 Preamble ................................................................................................... 6-14
Convert UPC-E to UPC-A ....................................................................................... 6-15
Convert UPC-E1 to UPC-A ..................................................................................... 6-16
EAN-8/JAN-8 Extend .............................................................................................. 6-17
Table of Contents
vii
Code 128 ...................................................................................................................... 6-17
Enable/Disable Code 128 ...................................................................................... 6-17
Enable/Disable UCC/EAN-128 ............................................................................... 6-18
Enable/Disable ISBT 128 ....................................................................................... 6-18
Code 39 ........................................................................................................................ 6-19
Enable/Disable Code 39 ........................................................................................ 6-19
Enable/Disable Trioptic Code 39 ............................................................................ 6-19
Convert Code 39 to Code 32 ................................................................................. 6-20
Code 32 Prefix ....................................................................................................... 6-21
Set Lengths for Code 39 ........................................................................................ 6-22
Code 39 Check Digit Verification ........................................................................... 6-23
Transmit Code 39 Check Digit ............................................................................... 6-24
Code 39 Full ASCII Conversion ............................................................................. 6-25
Code 93 ........................................................................................................................ 6-26
Enable/Disable Code 93 ........................................................................................ 6-26
Set Lengths for Code 93 ........................................................................................ 6-26
Code 11 ........................................................................................................................ 6-28
Code 11 .................................................................................................................. 6-28
Set Lengths for Code 11 ........................................................................................ 6-28
Code 11 Check Digit Verification ........................................................................... 6-30
Transmit Code 11 Check Digits ............................................................................. 6-31
Interleaved 2 of 5 (I 2 of 5) ........................................................................................... 6-32
Enable/Disable Interleaved 2 of 5 .......................................................................... 6-32
Set Lengths for Interleaved 2 of 5 .......................................................................... 6-32
I 2 of 5 Check Digit Verification .............................................................................. 6-34
Transmit I 2 of 5 Check Digit .................................................................................. 6-35
Convert I 2 of 5 to EAN-13 ..................................................................................... 6-35
Discrete 2 of 5 (D 2 of 5) .............................................................................................. 6-36
Enable/Disable Discrete 2 of 5 ............................................................................... 6-36
Set Lengths for Discrete 2 of 5 ............................................................................... 6-36
Codabar (NW - 7) ......................................................................................................... 6-38
Enable/Disable Codabar ........................................................................................ 6-38
Set Lengths for Codabar ........................................................................................ 6-38
CLSI Editing ........................................................................................................... 6-40
NOTIS Editing ........................................................................................................ 6-40
MSI ............................................................................................................................... 6-41
Enable/Disable MSI ................................................................................................ 6-41
Set Lengths for MSI ............................................................................................... 6-41
MSI Check Digits .................................................................................................... 6-43
Transmit MSI Check Digit(s) .................................................................................. 6-43
MSI Check Digit Algorithm ..................................................................................... 6-44
RSS (Reduced Space Symbology) .............................................................................. 6-45
RSS ........................................................................................................................ 6-45
Convert RSS to UPC/EAN ..................................................................................... 6-46
Redundancy Level ....................................................................................................... 6-47
Redundancy Level 1 .............................................................................................. 6-47
Redundancy Level 2 .............................................................................................. 6-47
Redundancy Level 3 .............................................................................................. 6-48
Redundancy Level 4 .............................................................................................. 6-48
LS3400 Product Reference Guide
Security Level ............................................................................................................... 6-49
Security Level 0 ....................................................................................................... 6-49
Security Level 1 ....................................................................................................... 6-49
Security Level 2 ....................................................................................................... 6-49
Security Level 3 ....................................................................................................... 6-49
Bi-directional Redundancy ............................................................................................ 6-50
Report Version .............................................................................................................. 6-50
Chapter 7: Miscellaneous Scanner Options
Introduction ................................................................................................................... 7-1
Scanning Sequence Examples ..................................................................................... 7-1
Errors While Scanning .................................................................................................. 7-1
Miscellaneous Default Parameters ............................................................................... 7-2
Miscellaneous Scanner Parameters ............................................................................. 7-3
Transmit Code ID Character ................................................................................... 7-3
Scan Angle .............................................................................................................. 7-4
Appendix A: Standard Defaults
Appendix B: Programming Reference
Symbol Code Identifiers ................................................................................................ B-1
AIM Code Identifiers ..................................................................................................... B-2
Appendix C: Sample Bar Codes
UPC-A ........................................................................................................................... C-1
UPC-E ........................................................................................................................... C-1
UPC-E1 ......................................................................................................................... C-1
EAN-13 ......................................................................................................................... C-2
EAN-8 ........................................................................................................................... C-2
Code 39 ........................................................................................................................ C-2
Trioptic Code 39 ............................................................................................................ C-2
Code 93 ........................................................................................................................ C-3
Code 11 ........................................................................................................................ C-3
Codabar ........................................................................................................................ C-3
MSI ................................................................................................................................ C-3
Interleaved 2 of 5 .......................................................................................................... C-4
Appendix D: Numeric Bar Codes
0, 1, 2 ............................................................................................................................ D-1
3, 4, 5, 6 ........................................................................................................................ D-2
7, 8, 9 ............................................................................................................................ D-3
Cancel ........................................................................................................................... D-3
Index
About This Guide
About This Guide
Overview
The LS3400 Product Reference Guide provides general instructions for setting up, operating, maintaining, and
troubleshooting the LS3400 scanner. The LS 3400 includes the following variations of the scanner:
•
LS3400-FZ20005: 1-D scanning
•
LS3400-ER20005: extended range 1-D scanning.
Chapter Descriptions
•
Chapter 1, Getting Started provides a product overview, unpacking instructions, and cable connection
information.
•
Chapter 2, Scanning describes parts of the scanner, beeper and LED definitions, and how to use the
scanner.
•
Chapter 3, Maintenance, Troubleshooting, & Specifications provides information on how to care for the
scanner, troubleshooting, and technical specifications.
•
Chapter 4, User Preferences provides programming bar codes for selecting user preference features for
the scanner.
•
Chapter 5, Scanner Emulation Interface provides information for setting up the scanner for Scanner
Emulation operation.
•
Chapter 6, Symbologies describes all symbology features and provides the programming bar codes
necessary for selecting these features for the scanner.
•
Chapter 7, Miscellaneous Scanner Options includes commonly used bar codes to customize how the
data is transmitted to the host device.
•
Appendix A, Standard Defaults provides a table of all host devices and miscellaneous scanner defaults.
•
Appendix B, Programming Reference provides a table of AIM code identifiers, ASCII character
conversions, and keyboard maps.
•
Appendix C, Sample Bar Codes includes sample bar codes.
•
Appendix D, Numeric Bar Codes includes the numeric bar codes to scan for parameters requiring
specific numeric values.
LS3400 Product Reference Guide
Notational Conventions
The following conventions are used in this document:
•
Italics are used to highlight the following:
-
Chapters and sections in this and related documents
•
bullets (•) indicate:
-
Action items
-
Lists of alternatives
-
Lists of required steps that are not necessarily sequential
•
Sequential lists (e.g., those that describe step-by-step procedures) appear as numbered lists.
•
Throughout the programming bar code menus, asterisks (*) are used to denote default parameter
settings.
Related Documents
The LS3400 Quick Reference Guide (p/n 72-86093-xx) provides general information to help the user get
started with the scanner. It includes basic operation instructions and start up bar codes.
For the latest versions of the LS3400 Quick Reference Guide and the LS3400 Product Reference Guide go to:
http://www.symbol.com/manuals.
*Baud Rate 9600
Feature/Option
* Indicates Default
About This Guide
xi
Service Information
If you have a problem with your equipment, contact the Symbol Global Customer Interaction Center for your
region (see below for contact information). Before calling, have the model number, serial number, and several
of your bar code symbols at hand.
Call the Global Customer Interaction Center from a phone near the scanning equipment so that the service
person can try to talk you through your problem. If the equipment is found to be working properly and the
problem is symbol readability, the Global Customer Interaction Center will request samples of your bar codes
for analysis at our plant.
If your problem cannot be solved over the phone, you may need to return your equipment for servicing. If that
is necessary, you will be given specific directions.
Symbol Technologies is not responsible for any damages incurred during shipment if the approved shipping
container is not used. Shipping the units improperly can possibly void the warranty. If the original shipping
container was not kept, contact Symbol to have another sent to you.
For service information, warranty information or technical assistance contact or call the Symbol Global
Customer Interaction Center. For contact information, go to: www.symbol.com/contactsupport.
If you purchased your Symbol product from a Symbol Business Partner, contact that Business Partner for
service.
For the latest version of this guide go to:http://www.symbol.com/manuals.
Chapter 1 Getting Started
Introduction
The scanner combines excellent scanning performance and advanced ergonomics to provide the best value in
a lightweight laser scanner, and ensures comfort and ease of use for extended periods of time.
Figure 1-1 LS 3400 Scanner
This scanner supports Scanner Emulation connection to a mobile computer or a controller which collects the
data and interprets it for the host.
Unpacking the Scanner
Remove the scanner from its packing and inspect it for damage. If the scanner was damaged in transit, call the
Symbol Global Customer Interaction Center. See page xi for contact information. KEEP THE PACKING. It is
the approved shipping container and should be used if the equipment ever needs to be returned for servicing.
1 - 2
LS3400 Product Reference Guide
Setting Up the Scanner
Installing the Interface Cable
1.
Loosen the two screws on the cable clamp at the bottom of the scanner and gently pull the clamp away
from the bottom of the scanner.
Figure 1-2 Loosening the Screws on the Cable Clamp
2.
Open the clamp and plug the interface cable modular connector into the cable interface port on the bottom
of the scanner handle.
Figure 1-3 Inserting the Cable
3.
Gently tug the cable to ensure the connector is properly secured.
1 - 3
4.
Close the clamp, push it back into place and tighten the screws on the clamp to secure the cable into the
bottom of the scanner.
Figure 1-4 Closing the Clamp
5.
Connect the other end of the interface cable to the host (see the specific host chapter for information on
host connections).
Removing the Interface Cable
1.
Loosen the two screws on the cable clamp at the bottom of the scanner and gently pull the clamp away
from the bottom of the scanner.
2.
Open the clamp and unplug the interface cable modular connector from the cable interface port on the
bottom of the scanner handle. Carefully slide out the cable.
3.
Follow the steps for Installing the Interface Cable on page 1-2 to connect a new cable.
Configuring the Scanner
Use the bar codes included in this manual to configure the scanner.
NOTE Different cables are required for different hosts. The connectors illustrated in each host
chapter are examples only. The connectors may be different than those illustrated, but the steps
to connect the scanner remain the same.
Chapter 2 Scanning
Introduction
This chapter provides beeper and LED definitions, techniques involved in scanning bar codes, general
instructions and tips about scanning, and decode zone diagrams.
Figure 2-1 Parts
Scan Trigger
Scan Window
LED Indicators
Tether Plate
2 - 2
LS3400 Product Reference Guide
Beeper Definitions
The scanner emits different beeper sequences and patterns to indicate its status. Table 2-1 defines beep
sequences that occur during both normal scanning and while programming the scanner.
LED Definitions
In addition to beeper sequences, the scanner uses the two-color LED to indicate its status. Table 2-2 defines
LED colors that display during scanning.
Scanning in Hand-Held Mode
Install and program the scanner (see Setting Up the Scanner on page 1-2). For assistance, contact the local
supplier or the Symbol Global Customer Interaction Center.
1.
Ensure the scanner is properly connected to the host (see the appropriate host chapter).
2.
Aim the scanner at the bar code.
Table 2-1 Standard Beeper Definitions
Beeper Sequence
Indication
Standard Use
1 short high beep
A bar code symbol was decoded (if decode beeper is
enabled).
Parameter Menu Scanning
Long low/long high beep
sequence
Incorrect programming sequence or ‘Cancel’ bar code
scanned. Scanner remains in program mode.
Short high/short low beep
sequence
Keyboard parameter selected. Enter value using bar
code keypad.
Short high/short low/short
high/short low beep sequence
Successful program exit with change in the parameter
setting.
Short low/short high/short
low/short high beep sequence
Out of host parameter storage space. Scan Set Default
Parameter on page 4-3.
Table 2-2 Standard LED Definitions
LED
Indication
Off
The scanner is on and ready to scan, or no power is
applied to the scanner.
Green
A bar code was successfully decoded.
Red
A data transmission error occurred.
2 - 3
3.
Press the scan trigger.
Figure 2-2 Scanning in Hand-Held Mode
4.
Ensure the scan line crosses every bar and space of the symbol.
5.
Upon successful decode, the scanner beeps, and the LED turns green. For more information on beeper
and LED definitions, see Table 2-1 and Table 2-2.
RIGHT
012345
WRONG
012345
2 - 4
LS3400 Product Reference Guide
Aiming
Do not hold the scanner directly over the bar code. Laser light reflecting directly back into the scanner from the
bar code is known as specular reflection. This specular reflection can make decoding difficult.
The scanner can be tilted up to 65° forward or back and achieve a successful decode (Figure 2-3). Simple
practice quickly shows what tolerances to work within.
Figure 2-3 Optimum Scan Angles
65°
65°
2 - 5
Decode Zone
Figure 2-4 LS 3400-FZ Decode Zone
2.5"
7.25"
5 mil
2.0"
15.75"
7.5 mil
1.0"
24"
13 mil
100% UPC
0"*
39.5"
26.5"
20 mil (80%MRD)
20 mil (31%MRD)
40 mil
55 mil
2.0"*
4.0"*
67.0"
84.0"
0
10
20
30
40
50
60
70
80
0
25.4
50.8
76.2
101.6
127.0
152.4
177.8
203.2
90
228.6
30
20
10
0
0
10
20
30
76.2
50.8
25.4
25.4
50.8
76.2
LS3400
FZ
Note: Typical performance at 68˚F (20˚C)
on high quality Code 39 and UPC symbols.
*Minimum distance determined by symbol length and scan angle
Depth of Field
W
i
d
t
h
o
f
F
i
e
l
d
in.
cm
in.
cm
2 - 6
LS3400 Product Reference Guide
Figure 2-5 LS 3400-ER Decode Zone
0.25"
20"
7.5 mil
2"
32"
10 mil
3"
69"
15 mil
3"
94"
20 mil
0
10
20
30
40
50
60
70
80
90
100
0
25.4
50.8
76.2
101.6
127.0
152.4
177.8
203.2
228.6
254.0
0
4
8
12
12
8
4
0
10.2
20.3
30.5
30.5
20.3
10.2
LS 3408
ER
LS3400
ER
Depth of Field
in.
cm
W
i
d
t
h
o
f
F
i
e
l
d
in.
cm
Note: Typical performance at 73.4˚F (23˚C)
on high quality Code 39 symbols.
15"
180"
55 mil
365"
70 mil reflective
*
540"
100 mil reflective
0
60
120
180
240
300
360
420
480
540
600
0
152.4
304.8
457.2
609.6
762.0
914.4
1066.8
1219.2
1371.6
1524.0
0
24
48
72
72
48
24
0
61.0
121.9
182.9
182.9
121.9
61.0
LS3400
ER
Depth of Field
in.
cm
W
i
d
t
h
o
f
F
i
e
l
d
in.
cm
Note: Typical performance at 73.4˚F (23˚C)
on high quality Code 39 symbols.
*Near range determined by degree of reflectivity and width of bar code.
Maintenance, Troubleshooting, &
Specifications
Chapter 3
Chapter 3 Maintenance, Troubleshooting, & Specifications
Introduction
This chapter provides suggested scanner maintenance, troubleshooting, technical specifications, and signal
descriptions (pinouts).
Maintenance
Cleaning the scan window is the only maintenance required. A dirty window may affect scanning accuracy.
•
Do not allow any abrasive material to touch the window.
•
Remove any dirt particles with a damp cloth.
•
Wipe the window using a tissue moistened with ammonia/water.
•
Do not spray water or other cleaning liquids directly onto the window.
3 - 2
LS3400 Product Reference Guide
Troubleshooting
Table 3-1 Troubleshooting
Problem
Possible Causes
Possible Solutions
Scanner emits short low/short
medium/short high beep sequence.
Scanner is powering up.
Normal when scanner is
plugged in.
Nothing happens when scan trigger is
pressed.
No power to the scanner.
Check the system power.
Ensure the power supply is
connected if the
configuration requires a
power supply.
Power supply is not
plugged in.
Interface/power cables are
loose.
Ensure all cable
connections are secure.
Laser comes on, but scanner does not
decode the bar code.
Scanner is not programmed
for the correct bar code
type.
Ensure the scanner is
programmed to read the
type of bar code being
scanned.
Bar code symbol is
unreadable.
Check the symbol to ensure
it is not defaced. Try
scanning test bar codes of
the same bar code type.
See Appendix C, Sample
Bar Codes for test bar
codes.
Bar code is out of range
from the scanner.
Move scanner closer to or
further from bar code.
Bar code is decoded, but data is not
transmitted to the host.
Interface cable is loose.
Ensure all cable
connections are secure.
Attached decoder is not
programmed for that bar
code type.
Enable the bar code type
for the decoder.
Scanned data is incorrectly displayed on
the host.
Scanner is not programmed
to work with the host.
Ensure editing options
(e.g., UPC-E to UPC-A
conversion) are properly
programmed.
Scanner emits long low/long high beep
sequence while it is being programming.
’Cancel’ bar code is
scanned.
Normal behavior.
NOTE If after performing these checks the symbol still does not decode, contact the distributor or
call the local Symbol Global Customer Interaction Center. See page xi for the telephone numbers.
Maintenance, Troubleshooting, & Specifications
3 - 3
Technical Specifications
Table 3-2 Technical Specifications
Item
Description
LS3400-FZ
LS3400-ER
Power Requirements
4.5 - 14VDC
Operating Current
180mA @ 5.2V
240mA @ 5.2V
Stand-By Current
50mA (max)
Power Source
Depending on host:
host powered
external power supply
Decode Capability
UPC/EAN, Bookland EAN, UPC/EAN with supplementals, Code
128, UCC/EAN 128, ISBT 128, Code 39, Trioptic Code 39, Code
93, Code 11, Interleaved 2 of 5, Discrete 2 of 5, Codabar (NW-7),
MSI, RSS.
Beeper Operation
User-selectable: Enable, Disable
Beeper Volume
User-selectable: Three levels
Beeper Tone
User-selectable: Three tones
Scan Repetition Rate
36 scans/second
Yaw Tolerance
± 50° from nominal
± 60° from nominal
Pitch Tolerance
± 65° from nominal
± 65° from nominal
Roll Tolerance
± 20° from nominal
± 10° from nominal
Print Contrast Minimum
25% minimum reflectance differential, measured at 650 nm.
Ambient Light Immunity
Indoor:
Outdoor:
450 Ft Candles (4,842 Lux)
8,000 Ft Candles (86,080 Lux)
450 Ft Candles (4,842 Lux)
4,000 Ft Candles (43,040 Lux)
Durability
6.5 ft (2.0 m) drops to concrete
Operating Temperature
-22° to 122° F (-30° to 50° C)
Storage Temperature
-40° to 158° F (-40° to 70° C)
Humidity
5% to 95% (non-condensing)
Weight (without cable)
12.35 oz. (350 g)
12.56 oz. (356 g)
Dimensions:
Height
Width
Depth
7.34 in. (18.65 cm)
4.82 in. (12.25 cm)
2.93 in. (7.43 cm)
3 - 4
LS3400 Product Reference Guide
Laser
650nm laser diode
Laser Classifications
IEC 825-1 Class 2
ESD
20 kV area discharge
8 kV contact discharge
Minimum Element Width
5 mil (0.127 mm)
7.5 mil (0.191 mm)
Interfaces Supported
Scanner Emulation
Electrical Safety
Certified Pending to UL1950, CSA C22.2 No.950.
EN60950/IC950
Input Transient Protection
IEC 1000-4-(2,3,4,5,6,11)
EMI
FCC Part 15 Class B, ICES-003 Class B European Union EMC
Directive, Australian SMA, Taiwan EMC, Japan
VCCI/MITI/Dentori
Table 3-2 Technical Specifications (Continued)
Item
Description
LS3400-FZ
LS3400-ER
Maintenance, Troubleshooting, & Specifications
3 - 5
Scanner Signal Descriptions
Figure 3-1 Scanner Cable Pinouts
Cable interface port
Interface cable
modular connector
Bottom of scanner
PIN 1
PIN 10
3 - 6
LS3400 Product Reference Guide
The signal descriptions in Table 3-3 apply to the connector on the scanner and are for reference only.
Table 3-3 Scanner Signal Pin-outs
Pin
Description
1
DBP
2
Power
3
Ground
4
SOS
5
Decode
6
Trigger
7
Enable
8
Reserved
9
Reserved
10
Reserved
Chapter 4 User Preferences
Introduction
The scanner can be programed to perform various functions, or activate different features. This chapter
describes each user preference feature and provides the programming bar codes necessary for selecting
these features for the scanner.
The scanner ships with the settings shown in the User Preferences Default Table on page 4-2 (also see
Appendix A, Standard Defaults for all host device and miscellaneous scanner defaults). If the default values
suit the requirements, programming may not be necessary.
Feature values are set by scanning single bar codes or short bar code sequences. The settings are stored in
non-volatile memory and are preserved even when the scanner is powered down.
To return all features to their default values, scan the Set All Defaults on page 4-3. Throughout the
programming bar code menus, default values are indicated with asterisks (*).
Scanning Sequence Examples
In most cases, only one bar code needs to be scanned to set a specific parameter value. For example, to set
the beeper tone to high, simply scan the High Frequency (beeper tone) bar code listed under Beeper Tone on
page 4-3. The scanner issues a fast warble beep and the LED turns green, signifying a successful parameter
entry.
Other parameters, such as specifying Laser On Time, require scanning several bar codes. See Laser On
Time on page 4-5 for a description of this procedure.
Errors While Scanning
Unless otherwise specified, if an error is made during a scanning sequence, just re-scan the correct parameter.
*High Frequency
Feature/Option
* Indicates Default
4 - 2
LS3400 Product Reference Guide
User Preferences Default Parameters
Table 4-1 lists the defaults for user preferences parameters. To change any option, scan the appropriate bar
code(s) provided in User Preferences on page 4-3.
NOTE See Appendix A, Standard Defaults for all user preferences, hosts, symbologies, and
miscellaneous default parameters.
Table 4-1 User Preferences Default Table
Parameter
Default
Page Number
User Preferences
Set Default Parameter
All Defaults
4-3
Beeper Tone
High
4-3
Beeper Volume
High
4-4
Power Mode
Reduced Power
4-4
Laser On Time
3.0 sec
4-5
Beep After Good Decode
Disable
4-6
Trigger Mode
Level
4-6
Aim Duration
0.0 sec
4-7
4 - 3
User Preferences
Set Default Parameter
Scanning this bar code returns all parameters to the default values listed in Table A-1 on page A-1.
Set All Defaults
Beeper Tone
To select a decode beep frequency (tone), scan the Low Frequency, Medium Frequency, or High
Frequency bar code.
Low Frequency
Medium Frequency
*High Frequency
4 - 4
LS3400 Product Reference Guide
Beeper Volume
To select a beeper volume, scan the Low Volume, Medium Volume, or High Volume bar code.
Low Volume
Medium Volume
*High Volume
Power Mode
This parameter determines whether or not the scanner enters reduced power mode after a decode attempt.
When in reduced power mode, the scanner draws less current from its power source.
Continuous On
*Reduced Power Mode
4 - 5
Laser On Time
This parameter sets the maximum time that decode processing continues during a scan attempt. It is
programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default Laser On Time is 3.0 seconds.
To set a Laser On Time, scan the bar code below. Next, scan two numeric bar codes in Appendix D, Numeric
Bar Codes that correspond to the desired on time. Single digit numbers must have a leading zero. For
example, to set a Laser On Time of 0.5 seconds, scan the bar code below, then scan the “0” and “5” bar codes.
In case of an error, or to change the selection, scan Cancel on page D-3.
Laser On Time
NOTE To optimize decode performance, you must set a longer Laser On Time for the attached
decoder than the Laser On Time of the LS3400.
4 - 6
LS3400 Product Reference Guide
Beep After Good Decode
Scan a bar code below to select whether or not the scanner beeps after a good decode. If Do Not Beep After
Good Decode is selected, the beeper still operates during parameter menu scanning and indicates error
conditions.
Beep After Good Decode
(Enable)
*Do Not Beep After Good Decode
(Disable)
Trigger Mode
The scanner has three trigger modes that can be used to scan bar codes. The desired trigger mode can be set
by using the bar codes below.
Level Trigger
When the trigger is pulled, an aiming dot appears for a programmable duration of time. After this time, the
aiming dot automatically turns into a standard laser scanning beam for a full decode session. The laser
scanning beam stays on until the laser-on timeout occurs, a decode occurs, or the trigger is released. If the
trigger is released before the aiming duration expires, the laser shuts off and no decode occurs.
*Level
NOTE To optimize decode performance, you must set a longer Laser On Time for the attached
decoder than the sum of the Aim Duration and the Laser On Time of the LS3400.
4 - 7
Trigger Mode (continued)
Two Stage - Option 1
When the trigger is pulled, an aiming dot appears. This aiming dot remains while the trigger is pulled. When the
trigger is released, the aiming dot automatically turns into a standard laser scanning beam for a full decode
session. The laser scanning beam stays on until the laser-on timeout occurs or a decode occurs. If the trigger
is pulled again while in a decode session, the scanner beam returns to an aiming dot.
Two Stage - Option 1
Two Stage - Option 2
When the trigger is pulled, an aiming dot appears. When the trigger is released, the aiming dot turns off. Pulling
the trigger twice in rapid succession turns on the standard laser scanning beam for a full decode session. The
laser scanning beam, stays on until the laser-on timeout occurs, a decode occurs, or the trigger is released.
Two Stage - Option 2
Aim Duration
When the scanner is in Level trigger mode (default mode), Aim Duration sets the amount of time the aiming dot
is seen before turning into a scanning beam. This parameter has no affect when the scanner is in either of the
Two Stage trigger modes. See Trigger Mode on page 4-6 for a description of each of the trigger modes.
The aim duration is programmable in 0.1 second increments, from 0.0 to 9.9 seconds. The default Aim
Duration is 0.0 seconds. When set to 0.0 seconds, no aiming pattern appears before a decode session.
To set an aim duration, scan the bar code below. Then scan two numeric bar codes, available in Appendix D,
Numeric Bar Codes, that correspond to the desired aim duration. Durations less than 1.0 seconds must have a
leading zero. For example, to set an aim duration of 0.5 seconds, scan the bar code below, followed by the ‘0’
and the ‘5’ bar codes. In case of an error, or to change the selection, scan Cancel on page D-3.
Aim Duration
Scanner Emulation Interface
Chapter 5
Chapter 5 Scanner Emulation Interface
Introduction
This chapter provides Scanner Emulation host information for setting up the scanner. This mode is used
whenever Scanner Emulation communication is needed. When Scanner Emulation is used, the scanner
attaches either to an external decoder or to a decoder integrated in a portable terminal or Point-of-Sale (POS)
terminal.
Throughout the programming bar code menus, default values are indicated with asterisks (*).
*Do Not Convert Bar Codes To Code 39
(Disable)
Feature/Option
* Indicates
Default
5 - 2
LS3400 Product Reference Guide
Connecting Using Scanner Emulation
To perform Scanner Emulation, connect the scanner to a mobile computer, or a controller which collects the
data and interprets it for the host.
Figure 5-1 Scanner Emulation Connection
1.
Attach the modular connector of the Scanner Emulation interface cable to the cable interface port on the
scanner. (See Installing the Interface Cable on page 1-2.).
2.
Connect the other end of the Scanner Emulation interface cable to the scanner port on the mobile
computer or controller.
3.
Ensure that all connections are secure.
4.
To modify any parameter options, scan the appropriate bar codes in this chapter.
Host Port Connector
Interface cable
NOTE Interface cables vary depending on configuration. The connectors illustrated in Figure 5-1
are examples only. The connectors may be different than those illustrated, but the steps to
connect the scanner remain the same.
Scanner Emulation Interface
5 - 3
Scanner Emulation Default Parameters
Table 5-1 lists the defaults for the Scanner Emulation Host. To change any option, scan the appropriate bar
code(s) provided in Scanner Emulation Host Parameters on page 5-4.
NOTE See Appendix A, Standard Defaults for all user preferences, hosts, symbologies, and
miscellaneous default parameters.
Table 5-1 Scanner Emulation Default Table
Parameter
Default
Page Number
Scanner Emulation Host Parameters
Convert Newer Code Types
Convert Newer Code
Types
5-4
Module Width
50 µs Module Width
5-4
Convert All Bar Codes to Code 39
Disable
5-5
Code 39 Full ASCII Conversion
Disable
5-5
Transmission Timeout
3 seconds
5-6
Transmit With Unknown Characters
Transmit With
Unknown Characters
5-7
Leading Margin
2 ms
5-8
5 - 4
LS3400 Product Reference Guide
Scanner Emulation Host Parameters
Convert Newer Code Types
The scanner supports a variety of code types that are customarily not decodable by attached decoder systems.
To allow compatibility in these environments, the scanner converts these code types to more commonly
decodable symbologies, as per the following chart. Symbologies not listed on this chart are transmitted
normally.
When decoding these code types with this parameter disabled, the scanner issues Convert Error beeps and
transmits no data.
*Convert Newer Code Types
Reject Newer Code Types
Module Width
The default module width is 50 µs. If desired, reduce this module width to 20 µs by scanning the corresponding
bar code below.
20 µs Module Width
*50 µs Module Width
Scan this code type:
Transmitted as:
Code 11
Code 39
RSS (14, Limited, and Expanded)
Code 128
Scanner Emulation Interface
5 - 5
Convert All Bar Codes to Code 39
Scan the appropriate bar code below to enable or disable the conversion of all bar code data to Code 39.
*Do Not Convert Bar Codes To Code 39
(Disable)
Convert All To Code 39
(Enable)
Code 39 Full ASCII Conversion
By default, any characters that do not have a corresponding character in the Code 39 symbology set are
replaced by a space. If this parameter is enabled, the data sent to the Scanner Emulation Host is encoded in
Code 39 Full ASCII. This setting requires that the Host be able to interpret Code 39 Full ASCII data.
This setting applies only if Convert to Code 39 is also enabled.
*Do Not Convert Code 39 To Full ASCII
(Disable)
Convert Code 39 To Full ASCII
(Enable)
5 - 6
LS3400 Product Reference Guide
Transmission Timeout
The Scanner Emulation Host transmits bar code data to the attached decoder and waits for the attached
decoder to assert the Decode signal, indicating successful transmission. If, after a specified amount of time,
the Decode signal has not been asserted (indicating that the attached decoder has not successfully received
the bar code data), a transmission error occurs.
Scan the appropriate bar code below to select the desired transmission timeout.
*3 Second Transmission Timeout
4 Second Transmission Timeout
5 Second Transmission Timeout
10 Second Transmission Timeout
30 Second Transmission Timeout
Scanner Emulation Interface
5 - 7
Transmit With Unknown Characters
Unknown characters are characters that the decoder does not recognize. When "Transmit With Unknown
Characters" is selected, all bar code data is sent except for unknown characters. When "Do Not Transmit With
Unknown Characters" is selected, bar codes containing at least one unknown character are not sent to the
decoder.
*Transmit With Unknown Characters
Do Not Transmit With Unknown Characters
5 - 8
LS3400 Product Reference Guide
Leading Margin
Scan a bar code below to select a leading margin duration.
1 ms Leading Margin
*2 ms Leading Margin
3 ms Leading Margin
5 ms Leading Margin
10 ms Leading Margin
Chapter 6 Symbologies
Introduction
This chapter describes all symbology features and provides the programming bar codes necessary for
selecting these features for the scanner. Before programming, follow the instructions in Chapter 1, Getting
Started.
The scanner is shipped with the settings shown in the Symbology Default Table on page 6-2 (also see
Appendix A, Standard Defaults for all host device and miscellaneous scanner defaults). If the default values
suit the requirements, programming may not be necessary. Features values are set by scanning single bar
codes or short bar code sequences.
To return all features to their default values, scan Set All Defaults on page 4-3.
Scanning Sequence Examples
In most cases, only one bar code needs to be scanned to set a specific parameter value. For example, to
transmit bar code data without the UPC-A check digit, scan the Do Not Transmit UPC-A Check Digit bar code
listed under Transmit UPC-A/UPC-E/UPC-E1 Check Digit on page 6-10. The scanner issues a fast warble
beep and the LED turns green, signifying a successful parameter entry.
Other parameters, such as Set Length(s) for D 2 of 5 require that several bar codes be scanned in the proper
sequence. See the individual parameter, like Set Length(s) for D 2 of 5, for this procedure.
Errors While Scanning
Unless otherwise specified, if an error is made during a scanning sequence, just re-scan the correct parameter.
6 - 2
LS3400 Product Reference Guide
Symbology Default Parameters
Table 6-1 lists the defaults for all symbologies parameters. To change any option, scan the appropriate bar
code(s) provided in this chapter.
NOTE See Appendix A, Standard Defaults for all user preferences, hosts, symbologies, and
miscellaneous default parameters.
Table 6-1 Symbology Default Table
Parameter
Default
Page Number
UPC/EAN
UPC-A
Enable
6-5
UPC-E
Enable
6-5
UPC-E1
Disable
6-6
EAN-13/JAN 13
Enable
6-6
EAN-8/JAN 8
Enable
6-7
Bookland EAN
Disable
6-7
Decode UPC/EAN/JAN Supplementals
(2 and 5 digits)
Ignore Supplementals
6-9
UPC/EAN/JAN Supplemental Redundancy
14
6-10
Transmit UPC-A Check Digit
Enable
6-10
Transmit UPC-E Check Digit
Enable
6-11
Transmit UPC-E1 Check Digit
Enable
6-11
UPC-A Preamble
System Character
6-12
UPC-E Preamble
System Character
6-13
UPC-E1 Preamble
System Character
6-14
Convert UPC-E to A
Disable
6-15
Convert UPC-E1 to A
Disable
-16
EAN-8/JAN-8 Extend
Disable
6-17
Code 128
Code 128
Enable
6-17
UCC/EAN-128
Enable
6-18
ISBT 128
Enable
6-18
6 - 3
Code 39
Code 39
Enable
6-19
Trioptic Code 39
Disable
6-19
Convert Code 39 to Code 32
Disable
6-20
Code 32 Prefix
Disable
6-21
Set Length(s) for Code 39
2 to 55
6-22
Code 39 Check Digit Verification
Disable
6-23
Transmit Code 39 Check Digit
Disable
6-24
Code 39 Full ASCII Conversion
Disable
6-25
Code 93
Code 93
Disable
6-26
Set Lengths for Code 93
4 to 55
6-26
Code 11
Code 11
Disable
6-28
Set Lengths for Code 11
4 to 41
6-28
Code 11 Check Digit Verification
One Check Digit
6-30
Transmit Code 11 Check Digits
Disable
6-31
Interleaved 2 of 5 (I 2 of 5)
Interleaved 2 of 5 (I 2 of 5)
Enable
6-32
Set Lengths for Interleaved 2 of 5
14
6-32
I 2 of 5 Check Digit Verification
Disable
6-34
Transmit I 2 of 5 Check Digit
Disable
6-35
Convert I 2 of 5 to EAN-13
Disable
6-35
Discrete 2 of 5 (D 2 of 5)
Discrete 2 of 5
Disable
6-36
Set Lengths for D 2 of 5
12
6-36
Codabar (NW - 7)
Codabar
Disable
6-38
Set Lengths for Codabar
5 to 55
6-38
CLSI Editing
Disable
6-40
Table 6-1 Symbology Default Table (Continued)
Parameter
Default
Page Number
6 - 4
LS3400 Product Reference Guide
NOTIS Editing
Disable
6-40
MSI
MSI
Disable
6-41
Set Lengths for MSI
6 to 55
6-41
MSI Check Digits
One
6-43
Transmit MSI Check Digit(s)
Disable
6-43
MSI Check Digit Algorithm
Mod 10/Mod 10
6-44
RSS (Reduced Space Symbology)
RSS 14
Disable
6-45
RSS Limited
Disable
6-45
RSS Expanded
Disable
6-46
Convert RSS to UPC/EAN
Disable
6-46
Symbology - Specific Security Levels
Redundancy Level
1
6-47
Security Levels
0
6-49
Bi-directional Redundancy
Disable
6-50
Report Software Version
6-50
Table 6-1 Symbology Default Table (Continued)
Parameter
Default
Page Number
6 - 5
UPC/EAN
Enable/Disable UPC-A
To enable or disable UPC-A, scan the appropriate bar code below.
*Enable UPC-A
Disable UPC-A
Enable/Disable UPC-E
To enable or disable UPC-E, scan the appropriate bar code below.
*Enable UPC-E
Disable UPC-E
6 - 6
LS3400 Product Reference Guide
Enable/Disable UPC-E1
UPC-E1 is disabled by default.
To enable or disable UPC-E1, scan the appropriate bar code below.
Enable UPC-E1
*Disable UPC-E1
Enable/Disable EAN-13
To enable or disable EAN-13, scan the appropriate bar code below.
*Enable EAN-13/JAN-13
Disable EAN-13/JAN-13
NOTE UPC-E1 is not a UCC (Uniform Code Council) approved symbology.
6 - 7
Enable/Disable EAN-8
To enable or disable EAN-8, scan the appropriate bar code below.
*Enable EAN-8/JAN-8
Disable EAN-8/JAN-8
Enable/Disable Bookland EAN
To enable or disable Bookland EAN, scan the appropriate bar code below.
Enable Bookland EAN
*Disable Bookland EAN
6 - 8
LS3400 Product Reference Guide
Decode UPC/EAN/JAN Supplementals
Supplementals are bar codes appended according to specific format conventions (e.g., UPC A+2, UPC E+2,
EAN 13+2). Six options are available.
•
If Decode UPC/EAN Only With Supplementals is selected, UPC/EAN symbols without supplementals
are not decoded.
•
If Ignore Supplementals is selected, and the scanner is presented with a UPC/EAN with a
supplemental, the UPC/EAN is decoded and the supplemental bar code is ignored.
•
An Autodiscriminate Option is also available. If this option is selected, choose an appropriate
“UPC/EAN/JAN Supplemental Redundancy,” value from the next page. A value of 14 or more is
recommended.
•
Enable 378/379 Supplemental Mode to enable only EAN13 bar codes starting with a ‘378’ or ‘379’
prefix to be delayed by the supplemental search process. All other UPC/EAN bar codes are exempted
from the search and are reported instantly upon their decode.
•
Select Enable 978 Supplemental Mode to enable only EAN13 bar codes starting with a ‘978’ prefix to
be delayed by the supplemental search process. All other UPC/EAN bar codes are exempted from the
search and are reported instantly upon their decode.
•
Select Enable Smart Supplemental Mode to enable only EAN13 bar codes starting with a ‘378’, ‘379’,
or ‘978’ prefix to be delayed by the supplemental search process. All other UPC/EAN bar codes are
exempted from the search and are reported instantly upon their decode.
Decode UPC/EAN/JAN Only With Supplementals
NOTE In order to minimize the risk of invalid data transmission, it is recommended to
select either to decode or ignore supplemental characters.
6 - 9
Decode UPC/EAN/JAN Supplementals (continued)
*Ignore Supplementals
Autodiscriminate UPC/EAN/JAN Supplementals
Enable 378/379 Supplemental Mode
Enable 978 Supplemental Mode
Enable Smart Supplemental Mode
6 - 10
LS3400 Product Reference Guide
UPC/EAN/JAN Supplemental Redundancy
With Autodiscriminate UPC/EAN/JAN Supplementals selected, this option adjusts the number of times a
symbol without supplementals is decoded before transmission. The range is from two to thirty times. 14 or
above is recommended when decoding a mix of UPC/EAN symbols with and without supplementals, and the
autodiscriminate option is selected. The default is set at 14.
Scan the bar code below to set a decode redundancy value. Next, scan two numeric bar codes from Appendix
D, Numeric Bar Codes. Single digit numbers must have a leading zero. In case of an error, or to change the
selection, scan Cancel on page D-3.
UPC/EAN/JAN Supplemental Redundancy
Transmit UPC-A/UPC-E/UPC-E1 Check Digit
The check digit is the last character of the symbol used to verify the integrity of the data. Scan the appropriate
bar code below to transmit the bar code data with or without the UPC-A, UPC-E or UPC-E1 check digit. It is
always verified to guarantee the integrity of the data.
UPC-A Check Digit
*Transmit UPC-A Check Digit
Do Not Transmit UPC-A Check Digit
6 - 11
UPC-E Check Digit
*Transmit UPC-E Check Digit
Do Not Transmit UPC-E Check Digit
UPC-E1 Check Digit
*Transmit UPC-E1 Check Digit
Do Not Transmit UPC-E1 Check Digit
6 - 12
LS3400 Product Reference Guide
UPC-A Preamble
Preamble characters are part of the UPC symbol consisting of Country Code and System Character. Three
options are given for transmitting UPC-A preamble to the host device: transmit System Character only, transmit
System Character and Country Code (“0” for USA), and no preamble transmitted. Select the appropriate option
to match the host system.
No Preamble
()
*System Character
( )
System Character & Country Code
(< COUNTRY CODE> )
6 - 13
UPC-E Preamble
Preamble characters are part of the UPC symbol consisting of Country Code and System Character. Three
options are given for transmitting UPC-E preamble to the host device: transmit System Character only, transmit
System Character and Country Code (“0” for USA), and no preamble transmitted. Select the appropriate option
to match the host system.
No Preamble
()
*System Character
( )
System Character & Country Code
(< COUNTRY CODE> )
6 - 14
LS3400 Product Reference Guide
UPC-E1 Preamble
Preamble characters are part of the UPC symbol consisting of Country Code and System Character. Three
options are given for transmitting UPC-E1 preamble to the host device: transmit System Character only,
transmit System Character and Country Code (“0” for USA), and no preamble transmitted. Select the
appropriate option to match the host system.
No Preamble
()
*System Character
( )
System Character & Country Code
(< COUNTRY CODE> )
6 - 15
Convert UPC-E to UPC-A
When enabled, UPC-E (zero suppressed) decoded data is converted to UPC-A format before transmission.
After conversion, the data follows UPC-A format and is affected by UPC-A programming selections (e.g.,
Preamble, Check Digit).
When disabled, UPC-E decoded data is transmitted as UPC-E data, without conversion.
Convert UPC-E to UPC-A
(Enable)
*Do Not Convert UPC-E to UPC-A
(Disable)
6 - 16
LS3400 Product Reference Guide
Convert UPC-E1 to UPC-A
When enabled, UPC-E1 decoded data is converted to UPC-A format before transmission. After conversion, the
data follows UPC-A format and is affected by UPC-A programming selections (e.g., Preamble, Check Digit).
When disabled, UPC-E1 decoded data is transmitted as UPC-E1 data, without conversion.
Convert UPC-E1 to UPC-A
(Enable)
*Do Not Convert UPC-E1 to UPC-A
(Disable)
6 - 17
EAN-8/JAN-8 Extend
When enabled, this parameter adds five leading zeros to decoded EAN-8 symbols to make them compatible in
format to EAN-13 symbols.
When disabled, EAN-8 symbols are transmitted as is.
Enable EAN/JAN Zero Extend
*Disable EAN/JAN Zero Extend
Code 128
Enable/Disable Code 128
To enable or disable Code 128, scan the appropriate bar code below.
*Enable Code 128
Disable Code 128
6 - 18
LS3400 Product Reference Guide
Enable/Disable UCC/EAN-128
To enable or disable UCC/EAN-128, scan the appropriate bar code below.
*Enable UCC/EAN-128
Disable UCC/EAN-128
Enable/Disable ISBT 128
To enable or disable ISBT 128, scan the appropriate bar code below.
*Enable ISBT 128
Disable ISBT 128
6 - 19
Code 39
Enable/Disable Code 39
To enable or disable Code 39, scan the appropriate bar code below.
*Enable Code 39
Disable Code 39
Enable/Disable Trioptic Code 39
Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges. Trioptic Code 39
symbols always contain six characters. To enable or disable Trioptic Code 39, scan the appropriate bar code
below.
Enable Trioptic Code 39
*Disable Trioptic Code 39
NOTE Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.
6 - 20
LS3400 Product Reference Guide
Convert Code 39 to Code 32
Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry. Scan the appropriate bar code
below to enable or disable converting Code 39 to Code 32.
Convert Code 39 to Code 32
(Enable)
*Do Not Convert Code 39 to Code 32
(Disable)
NOTE Code 39 must be enabled in order for this parameter to function.
6 - 21
Code 32 Prefix
Scan the appropriate bar code below to enable or disable adding the prefix character “A” to all Code 32 bar
codes.
Enable Code 32 Prefix
*Disable Code 32 Prefix
NOTE Convert Code 39 to Code 32 must be enabled for this parameter to function.
6 - 22
LS3400 Product Reference Guide
Set Lengths for Code 39
The length of a code refers to the number of characters (i.e., human readable characters), including check
digit(s) the code contains. Lengths for Code 39 may be set for any length, one or two discrete lengths, or
lengths within a specific range. If Code 39 Full ASCII is enabled, Length Within a Range or Any Length are
the preferred options.
One Discrete Length - This option allows the scanner to decode only those Code 39 symbols containing a
selected length. Lengths are selected from the numeric bar codes in Appendix D, Numeric Bar Codes. For
example, to decode only Code 39 symbols with 14 characters, scan Code 39 - One Discrete Length, then
scan 1 followed by 4. In case of an error, or to change the selection, scan Cancel on page D-3.
Code 39 - One Discrete Length
Two Discrete Lengths - This option allows the scanner to decode only those Code 39 symbols containing
either of two selected lengths. Lengths are selected from the numeric bar codes in Appendix D, Numeric Bar
Codes. For example, to decode only those Code 39 symbols containing either 2 or 14 characters, select Code
39 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. In case of an error, or to change the selection,
scan Cancel on page D-3.
Code 39 - Two Discrete Lengths
Length Within Range - This option allows the scanner to decode a Code 39 symbol with a specific
length range. The length range is selected from numeric bar codes in Appendix D, Numeric Bar Codes.
For example, to decode Code 39 symbols containing between 4 and 12 characters, first scan Code 39 -
Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading
zero). In case of an error, or to change the selection, scan Cancel on page D-3.
Code 39 - Length Within Range
Any Length - This option allows the scanner to decode Code 39 symbols containing any number of characters
within the scanner capability.
Code 39 - Any Length
NOTE When setting lengths for different bar code types by scanning single digit numbers, single
digit numbers must always be preceded by a leading zero.
6 - 23
Code 39 Check Digit Verification
When this feature is enabled, the scanner checks the integrity of all Code 39 symbols to verify that the data
complies with specified check digit algorithm. Only those Code 39 symbols which include a modulo 43 check
digit are decoded when this feature is enabled. This feature should only be enabled if the code 39 symbols
contain a Modulo 43 check digit.
Enable Code 39 Check Digit
*Disable Code 39 Check Digit
6 - 24
LS3400 Product Reference Guide
Transmit Code 39 Check Digit
Scan a bar code below to transmit Code 39 data with or without the check digit.
Transmit Code 39 Check Digit
(Enable)
*Do Not Transmit Code 39 Check Digit
(Disable)
NOTE Code 39 Check Digit Verification must be enabled for this parameter to function.
6 - 25
Code 39 Full ASCII Conversion
Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. To
enable or disable Code 39 Full ASCII, scan the appropriate bar code below.
Enable Code 39 Full ASCII
*Disable Code 39 Full ASCII
NOTE Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.
NOTE Code 39 Full ASCII to Full ASCII Correlation is host-dependent, and is therefore described
in the "ASCII Character Set" Table for the appropriate interface.
6 - 26
LS3400 Product Reference Guide
Code 93
Enable/Disable Code 93
To enable or disable Code 93, scan the appropriate bar code below.
Enable Code 93
*Disable Code 93
Set Lengths for Code 93
The length of a code refers to the number of characters (i.e., human readable characters), including check
digit(s) the code contains. Lengths for Code 93 may be set for any length, one or two discrete lengths, or
lengths within a specific range.
One Discrete Length - This option allows scanner to decode only those Code 93 symbols containing a
selected length. Lengths are selected from the numeric bar codes in Appendix D, Numeric Bar Codes. For
example, to decode only Code 93 symbols with 14 characters, scan Code 93 - One Discrete Length, then
scan 1 followed by 4. In case of an error, or to change the selection, scan Cancel on page D-3.
Code 93 - One Discrete Length
6 - 27
Set Lengths for Code 93 (continued)
Two Discrete Lengths - This option allows the scanner to decode only those Code 93 symbols containing
either of two selected lengths. Lengths are selected from the numeric bar codes in Appendix D, Numeric Bar
Codes. For example, to decode only those Code 93 symbols containing either 2 or 14 characters, select Code
93 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. In case of an error, or to change the selection,
scan Cancel on page D-3.
Code 93 - Two Discrete Lengths
Length Within Range - This option allows the scanner to decode a Code 93 symbol with a specific
length range. The length range is selected from numeric bar codes in Appendix D, Numeric Bar Codes.
For example, to decode Code 93 symbols containing between 4 and 12 characters, first scan Code 93 -
Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading
zero). In case of an error, or to change the selection, scan Cancel on page D-3.
Code 93 - Length Within Range
Any Length - This option allows the scanner to decode Code 93 symbols containing any number of characters
within the scanner’s capability.
Code 93 - Any Length
6 - 28
LS3400 Product Reference Guide
Code 11
Code 11
To enable or disable Code 11, scan the appropriate bar code below.
Enable Code 11
*Disable Code 11
Set Lengths for Code 11
The length of a code refers to the number of characters (i.e., human readable characters), including check
digit(s) the code contains. Lengths for Code 11 may be set for any length, one or two discrete lengths, or
lengths within a specific range.
One Discrete Length - This option allows the scanner to decode only those Code 11 symbols containing a
selected length. Lengths are selected from the numeric bar codes in Appendix D, Numeric Bar Codes. For
example, to decode only Code 11 symbols with 14 characters, scan Code 11 - One Discrete Length, then
scan 1 followed by 4. In case of an error, or to change the selection, scan Cancel on page D-3.
Code 11 - One Discrete Length
NOTE If you need to scan Code 11 bar codes, first enable either Convert Newer Code Types on
page 5-4 or Convert All Bar Codes to Code 39 on page 5-5 to allow data to transmit to the
attached device.
6 - 29
Set Lengths for Code 11 (continued)
Two Discrete Lengths - This option allows the scanner to decode only those Code 11 symbols containing
either of two selected lengths. Lengths are selected from the numeric bar codes in Appendix D, Numeric Bar
Codes. For example, to decode only those Code 11 symbols containing either 2 or 14 characters, select Code
11 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. In case of an error, or to change the selection,
scan Cancel on page D-3.
Code 11 - Two Discrete Lengths
Length Within Range - This option allows the scanner to decode a Code 11 symbol with a specific
length range. The length range is selected from numeric bar codes in Appendix D, Numeric Bar Codes.
For example, to decode Code 11 symbols containing between 4 and 12 characters, first scan Code 11 -
Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading
zero). In case of an error, or to change the selection, scan Cancel on page D-3.
Code 11 - Length Within Range
Any Length - This option allows the scanner to decode Code 11 symbols containing any number of characters
within the scanner capability.
Code 11 - Any Length
6 - 30
LS3400 Product Reference Guide
Code 11 Check Digit Verification
This feature allows the scanner to check the integrity of all Code 11 symbols to verify that the data complies
with the specified check digit algorithm. This selects the check digit mechanism for the decoded Code 11 bar
code. The options are to check for one check digit, check for two check digits, or disable the feature.
To enable this feature, scan the bar code below corresponding to the number of check digits encoded in the
Code 11 symbols.
Disable
*One Check Digit
Two Check Digits
6 - 31
Transmit Code 11 Check Digits
This feature selects whether or not to transmit the Code 11 check digit(s).
Transmit Code 11 Check Digit(s)
(Enable)
*Do Not Transmit Code 11 Check Digit(s)
(Disable)
NOTE Code 11 Check Digit Verification must be enabled for this parameter to function.
6 - 32
LS3400 Product Reference Guide
Interleaved 2 of 5 (I 2 of 5)
Enable/Disable Interleaved 2 of 5
To enable or disable Interleaved 2 of 5, scan the appropriate bar code below, and select an Interleaved 2 of 5
length from the following pages.
*Enable Interleaved 2 of 5
Disable Interleaved 2 of 5
Set Lengths for Interleaved 2 of 5
The length of a code refers to the number of characters (i.e., human readable characters), including check
digit(s) the code contains. Lengths for I 2 of 5 may be set for any length, one or two discrete lengths, or lengths
within a specific range.
One Discrete Length - This option allows the scanner to decode only those I 2 of 5 symbols containing a
selected length. Lengths are selected from the numeric bar codes in Appendix D, Numeric Bar Codes. For
example, to decode only I 2 of 5 symbols with 14 characters, scan I 2 of 5 - One Discrete Length, then scan 1
followed by 4. In case of an error, or to change the selection, scan Cancel on page D-3.
I 2 of 5 - One Discrete Length
6 - 33
Set Lengths for Interleaved 2 of 5 (continued)
Two Discrete Lengths - This option allows the scanner to decode only those I 2 of 5 symbols containing
either of two selected lengths. Lengths are selected from the numeric bar codes in Appendix D, Numeric Bar
Codes. For example, to decode only those I 2 of 5 symbols containing either 2 or 14 characters, select I 2 of 5
- Two Discrete Lengths, then scan 0, 2, 1, and then 4. In case of an error, or to change the selection, scan
Cancel on page D-3.
I 2 of 5 - Two Discrete Lengths
Length Within Range - This option allows the scanner to decode an I 2 of 5 symbol with a specific
length range. The length range is selected from numeric bar codes in Appendix D, Numeric Bar Codes.
For example, to decode I 2 of 5 symbols containing between 4 and 12 characters, first scan I 2 of 5 -
Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading
zero). In case of an error, or to change the selection, scan Cancel on page D-3.
I 2 of 5 - Length Within Range
6 - 34
LS3400 Product Reference Guide
Set Lengths for Interleaved 2 of 5 (continued)
Any Length - This option allows the scanner to decode I 2 of 5 symbols containing any number of characters
within the scanner capability.
I 2 of 5 - Any Length
I 2 of 5 Check Digit Verification
When this feature is enabled, the scanner checks the integrity of all I 2 of 5 symbols to verify the data complies
with either the specified Uniform Symbology Specification (USS), or the Optical Product Code Council (OPCC)
check digit algorithm.
*Disable
USS Check Digit
OPCC Check Digit
NOTE Due to the construction of the I 2 of 5 symbology, it is possible for a scan line covering only
a portion of the code to be interpreted as a complete scan, yielding less data than is actually
encoded in the bar code. To prevent this from happening, it is recommended that specific lengths
(I 2 of 5 - One Discrete Length - Two Discrete Lengths) be selected for I 2 of 5 applications.
6 - 35
Transmit I 2 of 5 Check Digit
Scan the appropriate bar code below to transmit I 2 of 5 data with or without the check digit.
Transmit I 2 of 5 Check Digit
(Enable)
*Do Not Transmit I 2 of 5 Check Digit
(Disable)
Convert I 2 of 5 to EAN-13
This parameter converts a 14 character I 2 of 5 code into EAN-13, and transmits to the host as EAN-13. In
order to accomplish this, the I 2 of 5 code must be enabled, and the code must have a leading zero and a valid
EAN-13 check digit.
Scanning a single bar code below, Convert I 2 of 5 to EAN-13 (Enable), accomplishes this function.
Convert I 2 of 5 to EAN-13
(Enable)
*Do Not Convert I 2 of 5 to EAN-13
(Disable)
6 - 36
LS3400 Product Reference Guide
Discrete 2 of 5 (D 2 of 5)
Enable/Disable Discrete 2 of 5
To enable or disable Discrete 2 of 5, scan the appropriate bar code below.
Enable Discrete 2 of 5
*Disable Discrete 2 of 5
Set Lengths for Discrete 2 of 5
The length of a code refers to the number of characters (i.e., human readable characters), including check
digit(s) the code contains. Lengths for D 2 of 5 may be set for any length, one or two discrete lengths, or
lengths within a specific range.
One Discrete Length - This option allows the scanner to decode only those D 2 of 5 symbols containing a
selected length. Lengths are selected from the numeric bar codes in Appendix D, Numeric Bar Codes. For
example, to decode only D 2 of 5 symbols with 14 characters, scan D 2 of 5 - One Discrete Length, then scan
1 followed by 4. In case of an error, or to change the selection, scan Cancel on page D-3.
D 2 of 5 - One Discrete Length
6 - 37
Set Lengths for Discrete 2 of 5 (continued)
Two Discrete Lengths - This option allows the scanner to decode only those D 2 of 5 symbols containing
either of two selected lengths. Lengths are selected from the numeric bar codes in Appendix D, Numeric Bar
Codes. For example, to decode only those D 2 of 5 symbols containing either 2 or 14 characters, select D 2 of
5 - Two Discrete Lengths, then scan 0, 2, 1, and then 4. In case of an error, or to change the selection,
scan Cancel on page D-3.
D 2 of 5 - Two Discrete Lengths
Length Within Range - This option allows the scanner to decode an D 2 of 5 symbol with a specific
length range. The length range is selected from numeric bar codes in Appendix D, Numeric Bar Codes.
For example, to decode D 2 of 5 symbols containing between 4 and 12 characters, first scan D 2 of 5 -
Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading
zero). In case of an error, or to change the selection, scan Cancel on page D-3.
D 2 of 5 - Length Within Range
Any Length - This option allows the scanner to decode D 2 of 5 symbols containing any number of characters
within the scanner capability.
D 2 of 5 - Any Length
NOTE Due to the construction of the D 2 of 5 symbology, it is possible for a scan line covering only
a portion of the code to be interpreted as a complete scan, yielding less data than is actually
encoded in the bar code. To prevent this from happening, it is recommended that specific lengths
(D 2 of 5 - One Discrete Length - Two Discrete Lengths) be selected for D 2 of 5 applications.
6 - 38
LS3400 Product Reference Guide
Codabar (NW - 7)
Enable/Disable Codabar
To enable or disable Codabar, scan the appropriate bar code below.
Enable Codabar
*Disable Codabar
Set Lengths for Codabar
The length of a code refers to the number of characters (i.e., human readable characters), including check
digit(s) the code contains. Lengths for Codabar may be set for any length, one or two discrete lengths, or
lengths within a specific range.
One Discrete Length - This option allows the scanner to decode only those Codabar symbols containing a
selected length. Lengths are selected from the numeric bar codes in Appendix D, Numeric Bar Codes. For
example, to decode only Codabar symbols with 14 characters, scan Codabar - One Discrete Length, then
scan 1 followed by 4. In case of an error, or to change the selection, scan Cancel on page D-3.
Codabar - One Discrete Length
Two Discrete Lengths - This option allows the scanner to decode only those Codabar symbols containing
either of two selected lengths. Lengths are selected from the numeric bar codes in Appendix D, Numeric Bar
Codes. For example, to decode only those Codabar symbols containing either 2 or 14 characters, select
Codabar - Two Discrete Lengths, then scan 0, 2, 1, and then 4. In case of an error, or to change the
selection, scan Cancel on page D-3.
Codabar - Two Discrete Lengths
6 - 39
Set Lengths for Codabar (continued)
Length Within Range - This option allows the scanner to decode a Codabar symbol with a specific
length range. The length range is selected from numeric bar codes in Appendix D, Numeric Bar Codes.
For example, to decode Codabar symbols containing between 4 and 12 characters, first scan Codabar -
Length Within Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading
zero). In case of an error, or to change the selection, scan Cancel on page D-3.
Codabar - Length Within Range
Any Length - This option allows the scanner to decode Codabar symbols containing any number of characters
within the scanner capability.
Codabar - Any Length
6 - 40
LS3400 Product Reference Guide
CLSI Editing
When enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and
tenth characters of a 14-character Codabar symbol. Enable this feature if the host system requires this data
format.
Enable CLSI Editing
*Disable CLSI Editing
NOTIS Editing
When enabled, this parameter strips the start and stop characters from a decoded Codabar symbol. Enable
this feature if the host system requires this data format.
Enable NOTIS Editing
*Disable NOTIS Editing
NOTE Symbol length does not include start and stop characters.
6 - 41
MSI
Enable/Disable MSI
To enable or disable MSI, scan the appropriate bar code below.
Enable MSI
*Disable MSI
Set Lengths for MSI
The length of a code refers to the number of characters (i.e., human readable characters), including check
digit(s) the code contains. Lengths for MSI may be set for any length, one or two discrete lengths, or lengths
within a specific range.
One Discrete Length - This option allows the scanner to decode only those MSI symbols containing a
selected length. Lengths are selected from the numeric bar codes in Appendix D, Numeric Bar Codes. For
example, to decode only MSI symbols with 14 characters, scan MSI - One Discrete Length, then scan 1
followed by 4. In case of an error, or to change the selection, scan Cancel on page D-3.
MSI - One Discrete Length
6 - 42
LS3400 Product Reference Guide
Set Lengths for MSI (continued)
Two Discrete Lengths - This option allows the scanner to decode only those MSI symbols containing
either of two selected lengths. Lengths are selected from the numeric bar codes in Appendix D, Numeric Bar
Codes. For example, to decode only those MSI symbols containing either 2 or 14 characters, select MSI - Two
Discrete Lengths, then scan 0, 2, 1, and then 4. In case of an error, or to change the selection, scan
Cancel on page D-3.
MSI - Two Discrete Lengths
Length Within Range - This option allows the scanner to decode an MSI symbol with a specific length
range. The length range is selected from numeric bar codes in Appendix D, Numeric Bar Codes. For
example, to decode MSI symbols containing between 4 and 12 characters, first scan MSI - Length Within
Range. Then scan 0, 4, 1, and 2 (single digit numbers must always be preceded by a leading zero). In case of
an error, or to change the selection, scan Cancel on page D-3.
MSI - Length Within Range
Any Length - This option allows the scanner to decode MSI symbols containing any number of characters
within the scanner capability.
MSI - Any Length
NOTE Due to the construction of the MSI symbology, it is possible for a scan line covering only a
portion of the code to be interpreted as a complete scan, yielding less data than is actually
encoded in the bar code. To prevent this from happening, it is recommended that specific lengths
(MSI - One Discrete Length - Two Discrete Lengths) be selected for MSI applications.
6 - 43
MSI Check Digits
With MSI symbols, one check digit is mandatory and always verified by the reader. The second check digit is
optional. If the MSI codes include two check digits, enable the verification of the second check digit by
scanning the bar code below.
See MSI Check Digit Algorithm on page 6-44 for the selection of second digit algorithms.
*One MSI Check Digit
Two MSI Check Digits
Transmit MSI Check Digit(s)
Scan a bar code below to transmit MSI data with or without the check digit.
Transmit MSI Check Digit(s)
(Enable)
*Do Not Transmit MSI Check Digit(s)
(Disable)
6 - 44
LS3400 Product Reference Guide
MSI Check Digit Algorithm
Two algorithms are possible for the verification of the second MSI check digit. Select the bar code below
corresponding to the algorithm used to encode the check digit.
MOD 10/MOD 11
*MOD 10/MOD 10
6 - 45
RSS (Reduced Space Symbology)
RSS
The variants of RSS are RSS 14, RSS Expanded, and RSS Limited. The limited and expanded versions have
stacked variants. Scan the appropriate bar code below to enable or disable each variant of RSS.
RSS 14
Enable RSS 14
*Disable RSS 14
RSS Limited
Enable RSS Limited
*Disable RSS Limited
NOTE If you need to scan RSS bar codes, first enable either Convert Newer Code Types on page
5-4 or Convert All Bar Codes to Code 39 on page 5-5 to allow data to transmit to the attached
device.
6 - 46
LS3400 Product Reference Guide
RSS Expanded
Enable RSS Expanded
*Disable RSS Expanded
Convert RSS to UPC/EAN
This parameter only applies to RSS-14 and RSS Limited symbols not decoded as part of a Composite symbol.
When this conversion is enabled, RSS-14 and RSS Limited symbols encoding a single zero as the first digit
have the leading '010' stripped and the bar code reported as EAN-13.
Bar codes beginning with two or more zeros but not six zeros have the leading '0100' stripped and the bar code
reported as UPC-A. The UPC-A Preamble parameter to transmit the system character and country code
applies to converted bar codes. Note that neither the system character nor the check digit can be stripped.
Enable Convert RSS to UPC/EAN
*Disable Convert RSS to UPC/EAN
6 - 47
Redundancy Level
The scanner offers four levels of decode redundancy. Higher redundancy levels are selected for decreasing
levels of bar code quality. As redundancy levels increase, the scanner’s aggressiveness decreases.
Select the redundancy level appropriate for the bar code quality.
Redundancy Level 1
The following code types must be successfully read twice before being decoded:
*Redundancy Level 1
Redundancy Level 2
The following code types must be successfully read twice before being decoded:
Redundancy Level 2
Code Type
Code Length
Codabar
8 characters or less
MSI
4 characters or less
D 2 of 5
8 characters or less
I 2 of 5
8 characters or less
Code Type
Code Length
All
All
6 - 48
LS3400 Product Reference Guide
Redundancy Level 3
Code types other than the following must be successfully read twice before being decoded. The following
codes must be read three times:
Redundancy Level 3
Redundancy Level 4
The following code types must be successfully read three times before being decoded:
Redundancy Level 4
Code Type
Code Length
MSI Plessey
4 characters or less
D 2 of 5
8 characters or less
I 2 of 5
8 characters or less
Codabar
8 characters or less
Code Type
Code Length
All
All
6 - 49
Security Level
The scanner offers four levels of decode security for UPC/EAN bar codes. Increasing levels of security are
provided for decreasing levels of bar code quality. There is an inverse relationship between security and
scanner decode speed, so be sure to choose only that level of security necessary for any given application.
Security Level 0
This is the default setting which allows the scanner to operate fastest, while providing sufficient security in
decoding “in-spec” UPC/EAN bar codes.
*Security Level 0
Security Level 1
As bar code quality levels diminish, certain characters become prone to misdecodes before others (i.e., 1, 2, 7,
8). If the scanner is misdecoding poorly printed bar codes, and the misdecodes are limited to these characters,
select this security level.
Security Level 1
Security Level 2
If the scanner is misdecoding poorly printed bar codes, and the misdecodes are not limited to characters 1, 2,
7, and 8, select this security level.
Security Level 2
Security Level 3
If Security Level 2 has been tried, and the scanner is still misdecoding, select this security level. Be advised,
selecting this option is an extreme measure against misdecoding severely out of spec bar codes. Selection of
this level of security may significantly impair the decoding ability of the scanner. If this level of security is
necessary, try to improve the quality of the bar codes.
Security Level 3
6 - 50
LS3400 Product Reference Guide
Bi-directional Redundancy
Bi-directional Redundancy is used for added security to linear code type security levels. When enabled, a bar
code must be successfully scanned in both directions (forward and reverse) before reporting a good decode.
Enable Bi-directional Redundancy
*Disable Bi-directional Redundancy
Report Version
Scan the bar code below to report the version of software currently installed in the digital scanner.
Report Software Version
Miscellaneous Scanner Options
Chapter 7
Chapter 7 Miscellaneous Scanner Options
Introduction
This chapter includes commonly used bar codes to customize how the data is transmitted to the host device. In
addition to these bar codes for data formatting, see each host chapter for the appropriate host connections and
host device features for the scanner. See Chapter 6, Symbologies for customizing data for transmission to the
host device.
Before programming, follow the instructions in Chapter 1, Getting Started.
The scanner is shipped with the settings shown in the Miscellaneous Scanner Options Default Table on page
7-2 (also see Appendix A, Standard Defaults for all host device and miscellaneous scanner defaults). If the
default values suit the requirements, programming may not be necessary. Features values are set by scanning
single bar codes or short bar code sequences.
Scanning Sequence Examples
In most cases, only one bar code needs to be scanned to set a specific parameter value.
Parameters, such as Prefix Value, require that several bar codes be scanned in the proper sequence. See
each individual parameter for descriptions of this procedure.
Errors While Scanning
Unless otherwise specified, if an error is made during a scanning sequence, re-scan the correct parameter.
7 - 2
LS3400 Product Reference Guide
Miscellaneous Default Parameters
Table 7-1 lists the defaults for miscellaneous scanner options parameters. To change any option, scan the
appropriate bar code(s) provided in the Miscellaneous Scanner Parameters section beginning on page 7-3.
NOTE See Appendix A, Standard Defaults for all user preferences, hosts, symbologies, and
miscellaneous default parameters.
Table 7-1 Miscellaneous Scanner Options Default Table
Parameter
Default
Page Number
Miscellaneous Scanner Options
Transmit Code ID Character
None
7-3
Scan Angle
Normal Angle
7-4
Miscellaneous Scanner Options
7 - 3
Miscellaneous Scanner Parameters
Transmit Code ID Character
A Code ID character identifies the code type of a scanned bar code. This may be useful when the scanner is
decoding more than one code type. In addition to any single character prefix already selected, the Code ID
character is inserted between the prefix and the decoded symbol.
Select no Code ID character, a Symbol Code ID character, or an AIM Code ID character. For Code ID
Characters, see Symbol Code Identifiers on page B-1 and AIM Code Identifiers on page B-2.
Symbol Code ID Character
AIM Code ID Character
*None
NOTE This parameter only functions if you enable Convert All Bar Codes to Code 39 on page 5-5.
7 - 4
LS3400 Product Reference Guide
Scan Angle
The scanner supports two scan angles. This parameter provides two options for the length of the laser
scanning beam. Use the bar codes below to change scan angles.
*Normal Angle
Alternate Angle