Procedure 6A - program the lock for tamper time

parameterS You can set the Tamper Time Wrong Tries parameter referring to the number of times the wrong credential can be tried to access before the lock goes into a Tamper Shutdown Mode. For example, if you program the lock to accept three wrong tries, the lock will tol- erate three wrong entries, staying locked but providing visual feedback (see visual mes- sage chart in rear section). After that, it will go into a Tamper Shutdown Mode and remain locked until the end of the Tamper Shutdown Time period - the length of that period is config ...

Definition of the Term “LearnLokTM ”

The term “LearnLok” with Kaba designed card based E-Plex Series lock refers to being able to enroll users’ ID cards and PINs directly at the lock’s keypad without uploading any software data to the lock from a handheld PDA unit. Here you make the lock “learn” the credential enrolling process simply by programming the lock at its keypad with your finger tip. The following E-Plex card based locks will work in “LearnLok” mode: E3600 and 5600; credentials supported are Mifare, DESFire and iClass, operates under 13.56 MHz frequency (ISO 14 ...

Procedure 3b - add / modify a service user Credential

A Service User is any person who needs access to the lock for a limited time period in order to perform a service, such as painting or repairs to the room or area. A Service User’s access credential is always PIN only. Typically a Service user’s PIN can be valid for either, one time use only (“one shot” entry), or from 1 through 96 hours expiry use. Additionally, you can assign “super” Service users whose PINs will never expire until you delete them from the lock. Required User Level: Master, Manager 1. Put the lock into � ...

Procedure 2A - Modify the master user access PIN

Required User Level: Master 1. To change the factory default Master PIN, follow the next three steps: 2. Put lock into Pushbutton Programming Mode. 3. Use the command, 000, to change the Master PIN, followed by the new Master PIN itself. 4. You must use 8 digits between 00000000 and 99999999 as follows: 000#MMMMMMMM#, we’ll use 000#87654321# as an example. 5. Enter the Master PIN again 87654321# for confirmation. 6. Example of Complete Entry: 000#87654321#87654321#. 7. Key in another # to indicate the end of programming. 8. After t ...

User - General Information

1. Master and Manager Credentials can do two different things: • Open the door by entering the Access Credential without # signs. • Put the lock into LearnLokTM Pushbutton Programming Mode by entering # before and after their Access Credential. 2. Each user - the Manager user, the Access user or the Access user occupies one of the available 300 locations in the user table of the lock’s memory, from 001 through 300. 3. By default, the Master user occupies user table location 000 which is reserved for the Master. 4. The Master and Manager users have a 1 ...

1. Put the lock into “LearnLokTM” Pushbutton Programming Mode -> # Master PIN

(or Manager credential) # 2. Enter Command 498# to de-activate all Access and Service users. Enter a last # to indicate the end of programming. Example of Complete Entry: 498# #. Procedure 17b - activate/De-activate lockout mode The Master user (and only the Master) can perform a global lockout if required, for example during a strike or fire, etc. At times like this you do not want anyone to return to work and so you should perform a global lockout temporarily. The following procedure can ...

4b. Pin & Card Mode: Procedure is similar to step 4a above, but after enrolling the

card you must not enter the # but continue with assigning the user’s PIN (4 to 8 digits as configured initially). Example of Complete Entry for Manager user ID=015 and PIN=9876: 101# 015# Present card (no # entry here) 9876# 9876# (to re-confirm) #. In the above examples, this Manager user’s card will open the lock if no PIN was assigned (card only mode), or the lock will open on entering the PIN first (9876) followed by presenting the associated card (PIN & Card mode). 5. The Manager User can also ...

Kaba EX3600 user guide recommended for: V-5324001, E-PLEX 2000, ELECTRONIC MORTISE LOCK, SIMPLEX 5000 CYLINDRICAL, SK-1123-FQ.

⚠️ Download Safety

The Lock Operation manual (40 pages) is completely safe to download (last scan date: 29/01/2026).

Related PDF Instructions for Kaba EX3600:

Lock Equipment: Frequently Requested

Have some Questions about Kaba EX3600 Device?

Get valuable and actionable advices from other Kaba EX3600 device users. Describe your problem or question, regarding the using of EX3600, in as much detail as possible, and other users will be able to answer you.