DEI -737AR Instructions

Specifications

Brand: DEI
Category: Remote Control
Model: -737AR (Instructions)
File Type: PDF
File Size: —
Pages: 2

Read Online

Read the DEI -737AR Instructions online using the built-in PDF viewer.

Text of the manual

DESCRIPTION OF CORDLESS REMOTE

ON OFF 3 4 2 1 5 POWER Fan speed button Select fan speed HIGH / MID / LOW / AUTO Auto - on timer is set Display this symbol while Signal transmission indicator Power Power on / off button (ceiling hidden - no swing) fan outlet or auto - swing Select swing direction of Louver control button (inactive) fan or dehum. Modes Select cooling,heating , Sleep Mode Button to set sleep mode I HR. OFF TIMER Display of set temperature Display the choosen fan speed Display the swing of fan outlet Display set time Timer For auto - on timer setting auto - off timer setting or Display the operating mode : Auto - off timer is set Display this symbol while COOL DEHUM. FAN HEATING MODE SLEEP FAN SWING Off / 1 hr. Auto off after one hour Operation Mode Display of sleep mode Temperature / Time Setting the temperature or time Button to increase or decrease

Fan : If selecting continuous fan mode, the green LED flashes.

Dehumidifying : If selecting dehumidifying mode , the 3 - way valve works as 10 minutes on and 10 minutes off. In this cycle , the fan speed turns into low speed. If the Room temp. is lower than 16 ,the 3 - way valve contact remains off. Sleep Mode : In cooling mode , when this function is set , then the temperature will go up 1 after one hour of setting ( in heating mode , it will go down 1 ) ; then at the second hour , the temperature will go up another 1 ( in heating mode , it will go down another 1 ) ; then this final temperature will be remained. ( The highest limitation of setting temperature is 30 and the lowest limitation is 16 ) Setting Reservation clock : After pre - setting timer for operation , the controller will be power - on or power - off according to the pre - set time. The workable distance of the receiver : as below illustration 5. ERROR MESSAGE If sensor is failed, the red LED on receiver flashes quickly. To solve the problem by checking the connection of sensor or replacing a new sensor. If the orange led freashes quickly , it means the internal circuit is failed. In this case , products should be sent back to the factory for repair. 4.2 Descriptions of DIPSW function : SW 2 : ON --- with 3 - minute delay protection for compressor. OFF --- without 3 - minute delay protection. ( Default ) ON --- fan running continously ( Default ) OFF --- fan running accompany with the on - off of 3 - way valve. 45 45 Maximum transmission range is 7M Externals of Receiver Backup power button Indicative LED 1. CAUTIONS 1.1 Please make sure the power is switched off before installment to avoid electric shock. .2 Please check the correct voltage corresponding to the same controller's power switch power supplying. .3 The installation of this product should be away from humid place. .4 The output contact capacity shows on the specification. Do not over load. .5 Please read the operation maunal carefully before installation. If damages are caused wiring, products would not be guaranteed. 2. SPECIFICATION 2.3 Power Supply AC110V / 220V 10% , 50 / 60Hz single phase 2.4 Sensor Range 5 3. OPERATING MODES 3.1 Operating mode Cooling / Heating / Fan / Dehumidifying 3.2 Setting range 16 30 ( under Cooling ) ; 3.7 control except fan mode, otherwise remains close. 4. FUNCTIONS 4.1 Descriptions of functions in Modes Cooling Mode when Room temp. Heating Mode 1 before 1 1 1 by incorrectly 2.1 Dimension : Receiver : 47 mm ( diameter ) 1 mm Power box : 140 mm ( L ) x 78 mm ( H ) x 73 mm ( W ) 1 mm 2.2 Operating Environment : Operating temp. : 0 50 ; Storage temp. : -10 65 , RH30% 90% ( non - condensing ) : : 45 2.5 Max. Securied Electrocity Loading : 3 - way valve --- 7A / 250VAC Chiller chain --- 3A / 250VAC ; fan --- 3A / 250VAC x 3 : : 16 32 ( under Heating ) 3.3 Fan control : Auto - fan / High / Mid / Low 3.4 Sleep mode : only available under Cooling or Heating. 3.5 Auto - on / Auto - off timer : setting range 1 12 hours 3.6 Backup power button : the backup power button designed on Receiver can turn on and off the controller for emergency in the case of remote control failure. Chiller chain : : Set temp. , green LED on and the 3 - way valve on. ( Green LED blinks while 3 - minutes 3 - minute delay protection starts ) ; when Roomtemp. Set temp. -2 , green LED flashes and the chiller contact off. : when Room temp. Set temp.,red LED on and the 3 - way valve on.( Red LED blinks while 3 - minute delay protection starts ) ; when Room temp. Set temp. 2 , red LED flashes and the chiller contact off. -737AR Operation Manual -737AR Operation Manual 5INS00226 Version 01

Other Remote Control Manuals