Black Box Advanced Console Server Operation & User’s Manual
Read Online
Read the Black Box Advanced Console Server Operation & User’s Manual online using the built-in PDF viewer.
Text of the manual
Advanced Console Server
Installation, Administration, and User’s Guide
Software Version 2.6.0
BLACK BOX® Corporation
1000 Park Drive
Lawrence, PA 15055-1018
877-877-2269
http://www.blackbox.com
Release Date: December 2005
© 2005 BLACK BOX® Corporation, all rights reserved
Information in this document is subject to change without notice.
BLACK BOX® is the registered trademark of BLACK BOX® Corporation in the United
States and other countries.
All trademarks, trade names, logos and service marks referenced herein, even when not
specifically marked as such, belong to their respective companies and are not to be considered
unprotected by law.
Before You Begin ......................................................1
Audience .............................................................................................. 1
Document Organization ....................................................................... 1
Related Documents .............................................................................. 3
BLACK BOX® firmware Upgrades ................................................ 4
Chapter 1: Introduction .............................................7
Overview .............................................................................................. 8
Product Models and Configurations ..................................................... 8
Connectors on the BLACK BOX® CS .............................................. 10
Accessing CS and Connected Devices ............................................... 10
Web Manager ..................................................................................... 11
Prerequisites for Using the Web Manager ......................................... 11
Types of Users .................................................................................... 12
Security .............................................................................................. 12
Authentication .................................................................................... 13
VPN .................................................................................................... 15
Packet Filtering on CS ....................................................................... 15
Structure of IP Filtering .................................................................. 15
Chain ........................................................................................... 16
Rule ............................................................................................. 16
Add Rule and Edit Rule Options .................................................... 17
SNMP ................................................................................................. 22
Notifications, Alarms, and Data Buffering ........................................ 23
Syslog Servers ................................................................................ 23
Prerequisites for Logging to Syslog Servers ............................... 23
Administering Users of Connected Devices ...................................... 24
Planning Access to Connected Devices ......................................... 24
Configuring Access to Connected Devices .................................... 25
CS and Power Management ............................................................... 25
Configuring Power Management ................................................... 26
Configuring Ports for Power Management by Authorized Users 27
Configuring Ports for Power Management Using the CLI ......... 27
Options for Managing Power ......................................................... 28
Power Management Through the Web Manager ........................ 28
Power Management from the CS Command Line ...................... 28
Chapter 2: Installation and Configuration .............29
Shipping Box Contents ...................................................................... 30
Important Pre-installation Requirements ........................................... 34
Java Plug-In Requirement for Serial Port Access .......................... 35
Basic Installation Procedures ............................................................. 36
Mounting the CS ............................................................................. 37
Making an Ethernet Connection ..................................................... 37
Connecting Servers and Other Devices to CS ................................ 38
Making a Direct Connection to Configure the Network Parameters.
......................................................................................................... 39
Powering on the CS and the Connected Devices ........................... 39
Configuring the Network Parameters ............................................. 40
Performing Basic Network Configuration Using the wiz Command
...................................................................................................... 40
Selecting A Security Profile Using the Web Manager ............... 45
Adding Users and Configuring Ports Using the Web Manager ..... 46
Enabling Ports and Assigning Users. .......................................... 46
Other Methods of Accessing the Web Manager ................................ 47
Installing PCMCIA Cards .................................................................. 48
Connecting AlterPath PM IPDUs ...................................................... 49
BLACK BOX® CS Installation, Administration, and User’s Guide
v
Chapter 3: Web Manager for Regular Users..........51
Using the Web Manager ..................................................................... 51
Features of Regular User Forms ........................................................ 53
Connect .............................................................................................. 54
Connect to CS ................................................................................. 55
Connect to Serial Ports ................................................................... 56
Port Access Requirements .......................................................... 56
Connection Protocols for Serial Ports ............................................ 56
TCP Port Numbers for Serial Ports ............................................. 57
IPDU Power Mgmt. ........................................................................... 58
Outlets Manager ............................................................................. 59
View IPDUs Info ............................................................................ 61
IPDU Multi-Outlet Ctrl ...................................................................... 62
Security .............................................................................................. 65
Chapter 4: Web Manager for Administrators ........67
BLACK BOX® Web Manager .......................................................... 68
Prerequisites for Using the Web Manager ...................................... 68
Common Tasks for CS Administrators .............................................. 69
Common Features of Administrator Forms ....................................... 70
Buttons and CS Information ........................................................... 70
Logging Into the Web Manager ......................................................... 72
Overview of Administrative Modes ................................................... 75
Wizard Mode .................................................................................. 76
Expert Mode ................................................................................... 76
Chapter 5: Configuring CS in Wizard Mode ..........79
Step 1: Security Profile ................................................................... 79
Pre-defined Security Profiles ...................................................... 79
Default Security Profile .............................................................. 80
Custom Security Profile .............................................................. 80
Serial Port Settings and Security Profiles ................................... 83
Step 2: Network Settings ................................................................ 87
Step 3: Port Profile ......................................................................... 90
Step 4: Access ................................................................................. 93
Step 5: Data Buffering .................................................................... 98
Step 6: System Log ....................................................................... 103
Chapter 6: Configuring the CS in Expert Mode...107
Overview of Menus and Forms ........................................................ 107
Mapping of the Expert Mode Menus and Forms ............................. 109
Description of Forms in Expert Mode ............................................. 110
Chapter 7: Applications Menu & Forms...............117
Applications ..................................................................................... 118
Connect ......................................................................................... 118
IPDU Power Mgmt. ...................................................................... 122
Outlets Manager ........................................................................ 123
View IPDUs Info ...................................................................... 126
Users Manager .......................................................................... 129
Configuration ............................................................................ 131
Software Upgrade [for the AlterPath PM] ................................ 133
IPDU Multi-Outlet Ctrl ................................................................ 135
Prerequisites for Multi-Outlet Control ...................................... 137
Power Management Icons ......................................................... 137
IPMI Power Management ............................................................. 141
Terminal Profile Menu ................................................................. 148
Chapter 8: Network Menu & Forms......................153
Network ............................................................................................ 154
Host Settings ................................................................................. 154
Syslog ........................................................................................... 159
PCMCIA Management ................................................................. 160
Configuring a Modem PCMCIA Card ...................................... 163
Configuring an ISDN PCMCIA Card ....................................... 166
Configuring a GSM PCMCIA Card ......................................... 168
BLACK BOX® CS Installation, Administration, and User’s Guide
vii
Configuring an Ethernet PCMCIA Card ................................... 171
Configuring a PCMCIA Compact Flash Card or a PCMCIA Hard
Disk Drive ................................................................................. 172
Configuring a Wireless LAN PCMCIA Card ........................... 174
Configuring a CDMA PCMCIA Card ...................................... 176
Ejecting a PCMCIA Card ......................................................... 178
VPN Connections ......................................................................... 178
SNMP ........................................................................................... 183
Firewall Configuration ................................................................. 188
Host Table .................................................................................... 203
Static Routes ................................................................................. 204
Chapter 9: Security Menu & Forms......................209
Users and Groups ......................................................................... 210
Adding a User ........................................................................... 211
Adding a Group ......................................................................... 212
Active Ports Sessions ................................................................... 214
Authentication .............................................................................. 216
Configuring Authentication for CS Logins ............................... 217
Configuring Authentication Servers for Logins to CS
and Connected Devices ............................................................. 218
Group Authorization on TACACS+ ......................................... 222
Security Profiles ........................................................................... 228
Pre-defined Security Profiles ................................................... 229
Default Security Profile ............................................................ 229
Custom Security Profile ............................................................ 229
Serial Port Settings and Security Profiles ................................. 232
Security Certificates ..................................................................... 238
Certificate for HTTP Security ................................................... 238
User Configured Digital Certificate .......................................... 238
X.509 Certificate on SSH ......................................................... 238
Chapter 10: Ports Menu & Forms.........................239
Physical Ports ............................................................................... 241
General ...................................................................................... 243
Connection Profiles ................................................................... 244
Console Access Server (CAS) Profile Connection Protocols ... 245
Terminal Server (TS) Profile Connection Protocols ................. 245
Bidirectional Telnet Protocol .................................................... 247
Modem and Power Management Connection Protocols ........... 248
Access ....................................................................................... 261
Authentication Methods and Fallback Mechanism ................... 263
Data Buffering .......................................................................... 266
Multi User ................................................................................. 270
Power Management .................................................................. 273
Other ......................................................................................... 279
Virtual Ports .................................................................................. 283
Ports Status ................................................................................... 289
Ports Statistics .............................................................................. 290
Chapter 11: Administration Menu & Forms.........293
System Information ...................................................................... 294
Notifications ................................................................................. 297
Email Notifications Entry ......................................................... 299
Pager Notifications Entry .......................................................... 302
SNMP Trap Notifications Entry ............................................... 304
Serial Ports Alarm Notification ................................................ 306
Time/Date ..................................................................................... 307
Setting Time and Date with NTP .............................................. 308
Boot Configuration ....................................................................... 309
Backup Configuration .................................................................. 312
Upgrade Firmware ........................................................................ 315
Reboot ........................................................................................... 318
Online Help .................................................................................. 319
Appendix A: Technical Specifications.................321
Appendix B: Safety, Regulatory, and Compliance In-
BLACK BOX® CS Installation, Administration, and User’s Guide
ix
formation ................................................................323
Safety Guidelines for Rack-Mounting the CS ................................. 323
Safety Precautions for Operating the Advanced Console Server ..... 324
Working inside the Advanced Console Server ................................ 326
Replacing the Battery ....................................................................... 326
FCC Warning Statement .................................................................. 327
Notice About FCC Compliance for all Advanced Console Server
Models .............................................................................................. 327
Canadian DOC Notice ...................................................................... 327
Aviso de Precaución S-Mark Argentina .......................................... 328
Trabajar dentro del Advanced Console Server ................................ 329
Batería .............................................................................................. 329
Appendix C: Supported PCMCIA Cards ..............331
Glossary .................................................................335
Index .......................................................................353
Typographic Conventions................................................ 3
Table v-2:
Other Terms and Conventions......................................... 4
Table 1-1:
Model Numbers and Configuration Options ................... 8
Table 1-2:
CS Supported Authentication Methods......................... 13
Table 1-3:
Filter Options for Packet Filtering Rules....................... 17
Table 1-4:
TCP Protocol Packet Filtering Options ......................... 18
Table 1-5:
UDP Protocol Packet Filtering Options ........................ 19
Table 1-6:
LOG Target Action Options .......................................... 21
Table 1-7:
Tasks for Configuring Access to Connected Devices ... 25
Table 1-8:
Tasks for Configuring Power Management................... 27
Table 1-9:
Power Management Options in the Web Manager........ 28
Table 2-1:
Shipping Box Contents for LS1004A - LS1048A ........ 30
Table 2-2:
Shipping Box Contents for LS1001A............................ 33
Table 2-3:
CS Basic Installation Tasks ........................................... 36
Table 2-4:
Tasks Related to Connecting AlterPath PMs................. 50
Table 3-1:
Common Screen Information ........................................ 53
Table 3-2:
Java Applet Buttons...................................................... 55
Table 3-3:
Serial Ports Connection Protocols................................. 57
Table 3-4:
Regular User > Outlet Management Buttons ................ 60
Table 3-5:
Regular User > Information on the View IPDUs Info Form
... .................................................................................... 61
Table 3-6:
Regular User > IPDU Multi-Outlet Ctrl. Form Icons.... 64
Table 3-7:
Regular User > Password Management Form............... 65
Table 4-1:
Administrator > Common Administrative Tasks .......... 69
Administrator > Web Manager Buttons......................... 70
Table 4-3:
Administrator > Options for Trying, Saving, and Restoring
Configuration Changes.................................................. 71
Table 4-4:
Administrator > Logout Button and Other Information in
the Upper Right ............................................................. 72
Table 4-5:
Administrator > CS Configuration and Expert Menus
Chapters......................................................................... 77
Table 5-1:
Wizard > Enabled services to access the CS under each
security profile............................................................... 81
Table 5-2:
Wizard > Enabled services to access the serial ports under
each security profile. ..................................................... 81
Table 5-3:
Wizard > Enabled protocols for each security profile
shown with a check mark. ............................................. 82
Table 5-4:
Wizard > Serial Port Profile Parameters and Usage...... 91
Table 5-5:
Wizard > Add User Dialog: Field Names and Definitions
.. ..................................................................................... 95
Table 5-6:
Wizard > Data Buffering Field Names and Definitions . ...
... .................................................................................. 100
Table 5-7:
Wizard > Differences Between Remote and Local
Buffering...................................................................... 101
Table 5-8:
CS Configuration and Expert Menus Chapters ........... 105
Table 6-1:
Expert Mode Menu and Forms.................................... 109
Table 6-2:
Expert > Applications................................................. 110
Table 6-3:
Expert > Network .........................................................111
Table 6-4:
Expert > Security......................................................... 112
Table 6-5:
Expert > Ports.............................................................. 112
Table 6-6:
Administration............................................................. 113
Table 7-1:
Expert > Applications Menu ....................................... 117
Table 7-2:
Expert > Outlets Manager Icons Description .............. 124
Table 7-3:
Expert > View IPDUs General Information ................ 127
Table 7-4:
Expert > View IPDUs Unit Information...................... 128
Table 7-5:
Expert > IPDU Multi-Outlet Ctrl form icons .............. 138
Table 7-6:
Expert > IPMI Information.......................................... 143
Table 7-7:
Expert > IPMI Power Mgmt. Form Icons ................... 143
Table 8-1:
Expert > Network Menu ............................................. 153
BLACK BOX® CS Installation, Administration, and User’s Guide
xiii
Table 8-2:
Expert > Host Settings Form Fields ............................ 155
Table 8-3:
Expert > Form Fields for a Modem Card.................... 164
Table 8-4:
Expert > Form Fields for an ISDN Card ..................... 167
Table 8-5:
Expert > Form Fields For a GSM Card....................... 170
Table 8-6:
Expert > Form Fields for an Ethernet Card................. 171
Table 8-7:
Expert > Form Fields for a Compact Flash/Hard Disk 173
Table 8-8:
Expert > Form Fields for a Wireless LAN Card. ........ 175
Table 8-9:
Expert > Form Fields for a CDMA Card..................... 176
Table 8-10: Expert > Field and Menu Options for Configuring a VPN
Connection................................................................... 181
Table 8-11: Expert > Fields and Menu Options for SNMP
Configuration............................................................... 185
Table 8-12: Expert > Tasks for Configuring SNMP....................... 188
Table 8-13: Expert > TCP Options Fields ...................................... 195
Table 8-14: Expert > UDP Options Fields...................................... 196
Table 8-15: Expert > Firewall Configuration Input and Output
Interface, and Fragments Fields Definitions. .............. 198
Table 8-16: Expert > Target LOG Options Selection Fields........... 199
Table 8-17: Expert > Reject Options Sections............................... 200
Table 8-18: Expert > Fields and Menus for Configuring Static Routes
.... ................................................................................. 207
Table 9-1:
Expert > Security Menu............................................... 209
Table 9-2:
Expert > Add User Dialog Field Names and Definitions...
... .................................................................................. 211
Table 9-3:
Expert > Active Ports Sessions Information. .............. 215
Table 9-4:
Tasks for Setting up Authentication Servers. .............. 219
Table 9-5:
Expert > Enabled services to access the CS under each
security profile............................................................. 230
Table 9-6:
Expert > Enabled services to access the serial ports under
each security profile. ................................................... 230
Table 9-7:
Expert > Enabled protocols for each security profile
shown with a check mark. ........................................... 231
Table 9-8:
Configuring CS in Expert Mode.................................. 237
Table 10-1: Expert > Ports Menu.................................................... 239
Table 10-2: Expert > Console Connection Protocols...................... 245
Table 10-3: Expert > Terminal Server (TS) Connected Protocols.. 246
Table 10-4: Expert > Protocols for Serial Ports Connected to
Modems or IPDUs....................................................... 248
Table 10-5: Expert > Access Form Fields ...................................... 262
Table 10-6: Expert > Authentication Methods ............................... 264
Table 10-7: Expert > Procedures to Configure an Authentication
Server........................................................................... 266
Table 10-8: Expert > Data Buffering Form Fields.......................... 267
Table 10-9: Expert > Multi User Form Fields ................................ 271
Table 10-10: Expert > Options on the “Allow Multiple Sessions” Menu
..... ................................................................................ 272
Table 10-11: Expert > Power Management Form Fields................. 274
Table 10-12: Expert > Ports > Physical Ports > Other Form Fields . 280
Table 10-13: Expert > New/Modify Port Dialog Box Fields............ 285
Table 10-14: Expert > Port Status Read-Only Form......................... 290
Table 10-15: Expert > Ports>Port Status Read-Only Form .............. 291
Table 11-1: Expert > Administration Menu.................................... 293
Table 11-2: System Information ..................................................... 296
Table 11-3: Expert > Notifications Form Fields............................. 298
Table 11-4: Expert > Email Notifications Dialog Box Fields ........ 300
Table 11-5: Expert > Pager Notifications Dialog Box.................... 303
Table 11-6: Expert > SNMP Trap Notifications Dialog Box ......... 305
Table 11-7: Expert > Boot Configuration Form Fields................... 310
Table 11-8: Expert > Backup Config Type FTP Form Fields and
Buttons......................................................................... 313
Table 11-9: Expert > Backup Config Type Storage Device Form.. 314
Table 11-10: Expert > Upgrade Firmware Form Fields ................... 316
Table C-1:
Supported PCMCIA Cards.......................................... 331
CS Front with PCMCIA Card Slots.............................. 8
Figure 1-2:
CS Back with Connectors ............................................. 8
Figure 1-3:
BLACK BOX® CS family of Advanced Console .........
Servers........................................................................... 9
Figure 1-4:
CS Connectors............................................................. 10
Figure 1-5:
IPDU Integration With CS.......................................... 26
Figure 2-1:
CS Setup Example ...................................................... 30
Figure 2-2:
Security Advisory Console Message .......................... 42
Figure 2-3:
Front Panel PCMCIA Card Slots................................ 48
Figure 2-4:
PCMCIA Eject Button in Web Manager..................... 49
Figure 2-5:
AlterPath PMs Connected to the CS........................... 50
Figure 3-1:
Regular User > Web Manager Login form ................. 52
Figure 3-2:
Regular User Form...................................................... 53
Figure 3-3:
Regular User > Connect Form .................................... 54
Figure 3-4:
Java Applet.................................................................. 55
Figure 3-5:
Regular User > IPDU Power Mgmt. Forms................ 58
Figure 3-6:
Regular User > Outlets Manager (no permissions)..... 59
Figure 3-7:
Regular User > Outlets Manager (with permissions).. 59
Figure 3-8:
Regular User > View IPDUs Info ............................... 61
Figure 3-9:
Regular User > IPDU Multi-Outlet (no permissions). 63
Figure 3-10:
Regular User > IPDU Multi-Outlet (wit permissions)......
Administrator > Web Manager Buttons ...................... 70
Figure 4-2:
Administrator > Web Manager Login Form ............... 73
Figure 4-3:
Administrator > Multi Administrator Login Message 74
Figure 4-4:
Administrator > Security Advisory Message.............. 75
Figure 4-5:
Example of Web Manager Form in Wizard Mode...... 76
Figure 4-6:
Example of Web Manager Form in Expert Mode....... 77
Figure 5-1:
Administrator > Physical Ports Factory Settings ........ 83
Figure 5-2:
Security and Serial Ports Configuration Alert ............ 83
Figure 5-3:
Security Advisory Dialog Box.................................... 84
Figure 5-4:
Wizard > Step 1: Security Profile Form...................... 85
Figure 5-5:
Custom Security Profile Dialog Box .......................... 86
Figure 5-6:
Wizard > Step 2: Network Settings - DHCP disabled. 88
Figure 5-7:
Wizard > Step 2: Network Settings - DHCP enabled. 89
Figure 5-8:
Wizard > Step 3: Port Profile ...................................... 90
Figure 5-9:
Wizard > Step 4:Access .............................................. 94
Figure 5-10:
Wizard > Step 4: Access Add User Dialog Box ......... 95
Figure 5-11:
Wizard > Step 4: Change Password Dialog Box......... 96
Figure 5-12:
Wizard > Step 5: Data Buffering [Inactive] ................ 98
Figure 5-13:
Wizard > Step 5: Data Buffering [Local].................... 99
Figure 5-14:
Wizard > Step 5: Data Buffering [Remote]............... 100
Figure 5-15:
Wizard > Step 6: System Log ................................... 104
Figure 6-1:
Expert Mode Screen Elements.................................. 108
Figure 7-1:
Expert > Applications Menu Options ....................... 118
Figure 7-2:
Expert > Applications > Connect Form .................... 119
Figure 7-3:
Expert > SSH session Java Applet............................ 120
Figure 7-4:
Expert > Serial Port Java Applet............................... 121
Figure 7-5:
Expert > IPDU Power Mgmt. Tab Options............... 122
Figure 7-6:
Expert > Applications > IPDU Power Mgmt. > Outlets
BLACK BOX® CS Installation, Administration, and User’s Guide
xvii
Manager..................................................................... 124
Figure 7-7:
Expert > Outlets Manager Icons ............................... 125
Figure 7-8:
Expert > Edit Outlets Dialog Box............................. 125
Figure 7-9:
IPDU Power Mgmt. > View IPDUs Info .................. 126
Figure 7-10:
IPDU Power Mgmt> Users Manager....................... 129
Figure 7-11:
Expert > IPDU Power Mgmt. > Users Manager > Add
User ........................................................................... 129
Figure 7-12:
Expert > Applications > IPDU Power Mgmt. >
Configuration ............................................................ 132
Figure 7-13:
Expert > Applications > IPDU Power Mgmt. > Software
Upgrade..................................................................... 133
Figure 7-14:
Expert > Applications > IPDU Multi-Outlet Ctrl .... 136
Figure 7-15:
Expert > Applications > Multi-Outlet Ctrl [not
configured]................................................................ 137
Figure 7-16:
Expert > Applications > Multi-Outlet Control Icons138
Figure 7-17:
Expert > Applications > IPMI Power Mgmt............. 141
Figure 7-18:
Expert > IPMI Power Mgmt. “Add/Edit IPMI Device”
Dialog Boxes............................................................. 142
Figure 7-19:
Expert > IPMI Power Mgmt. Device Entry Example142
Figure 7-20:
Expert > Serial Port > Power Management > Enable
Power Management................................................... 146
Figure 7-21:
Expert > Power Management Add Outlet Dialog Box ..
................................................................................... 146
Figure 7-22:
Expert > Serial Port > Power Management > User
Permissions ............................................................... 147
Figure 7-23:
Expert > Serial Port > Power Management > Enable
IPMI .......................................................................... 148
Figure 7-24:
Expert > Applications > Terminal Profile Menu ...... 149
Figure 7-25:
Expert >Terminal Profile Menu “Add Option” Dialog
Expert > Terminal Profile Menu Example................ 150
Figure 8-1:
Expert > Network > Host Settings [DHCP Enabled] 154
Figure 8-2:
Expert > Network > Host Settings [DHCP Disabled]155
Figure 8-3:
Expert > Network > Syslog....................................... 159
Figure 8-4:
Expert > Network > PCMCIA Management ............ 161
Figure 8-5:
Expert > PCMCIA Modem Card Configuration Dialog
Box............................................................................ 164
Figure 8-6:
Expert > PCMCIA Modem Card Configuration Dialog
Box -PPP................................................................... 165
Figure 8-7:
Expert > Modem PCMCIA Card Configuration Dialog
Box - Call Back......................................................... 165
Figure 8-8:
Expert > ISDN PCMCIA Card Configuration Dialog
Box............................................................................ 167
Figure 8-9:
Expert > GSM PCMCIA Card Configuration Dialog
Box............................................................................ 169
Figure 8-10:
Expert > GSM PCMCIA Card Configuration Dialog
Box - Call Back......................................................... 169
Figure 8-11:
Expert > Ethernet PCMCIA Card Configuration Dialog
Box............................................................................ 171
Figure 8-12:
Expert > PCMCIA Compact Flash/Hard Disk
Configuration Dialog Box....................................... 173
Figure 8-13:
Expert > PCMCIA Wireless LAN Card Configuration
Dialog Box ................................................................ 174
Figure 8-14:
Expert > PCMCIA CDMA Card Configuration Dialog
Box............................................................................ 176
Figure 8-15:
Expert > Network > VPN Connections..................... 179
Figure 8-16:
Expert > VPN “New/Modify Connection” Dialog Box..
................................................................................... 180
Figure 8-17:
Expert > Network > SNMP...................................... 184
BLACK BOX® CS Installation, Administration, and User’s Guide
xix
Figure 8-18:
Expert > “New/Mod SNMP v1 v2 Configuration”
Dialog Box ................................................................ 186
Figure 8-19:
Expert > “New/Mod SNMP v3 Configuration” Dialog
Box............................................................................ 186
Figure 8-20:
Expert > Network > Firewall Configuration............. 188
Figure 8-21:
Expert > Firewall Configuration “Edit Chain” Dialog
Box............................................................................ 189
Figure 8-22:
Firewall Configuration “User-defined Chain” Message.
................................................................................... 190
Figure 8-23:
Firewall Configuration “Delete Default Chain” Message
................................................................................... 190
Figure 8-24:
Expert > Firewall Configuration “Add Chain” Dialog
Box............................................................................ 191
Figure 8-25:
Firewall Configuration “Edit Rules for chain_name”
Form.......................................................................... 191
Figure 8-26:
Firewall Configuration “Edit Rules for chain_name”
Buttons ...................................................................... 192
Figure 8-27:
Expert > Firewall Configuration “Add Rule” and “Edit
Rule” Dialog Boxes .................................................. 192
Figure 8-28:
Firewall Configuration “Add Rule” and “Edit Rule” ....
Target Menu Options................................................. 193
Figure 8-29:
Firewall Configuration “Add Rule” and “Edit Rule”
Source and Destination IP and Mask Fields ............. 193
Figure 8-30:
Firewall Configuration “Add Rule” and “Edit Rule”
Protocol Menu Options ............................................. 194
Figure 8-31:
Firewall Configuration “Add Rule” and “Edit Rule”
Numeric Protocol Fields ........................................... 194
Figure 8-32:
Firewall Configuration “Add Rule” and “Edit Rule”
TCP Protocol Fields and Menu Options ................... 195
Firewall Configuration “Add Rule” and “Edit Rule”
UDP Protocol Fields ................................................. 196
Figure 8-34:
Firewall Configuration “Add Rule” and “Edit Rule”
ICMP Type Menu Options........................................ 197
Figure 8-35:
Firewall Configuration Input and Output Interface Fields
and Fragments Menu Options................................... 198
Figure 8-36:
Firewall Configuration “Add Rule” and “Edit Rule”
LOG Target Fields..................................................... 199
Figure 8-37:
Firewall Configuration “Add Rule” and “Edit Rule”
REJECT Target Menu Options ................................. 200
Figure 8-38:
Expert > Network > Host Tables............................... 204
Figure 8-39:
Expert > Network > Static Routes ............................ 205
Figure 8-40:
Expert > Static Routes “Add” and “Edit” Dialog Boxes -
Default Route ............................................................ 205
Figure 8-41:
Expert > Static Routes “Add” and “Edit” Dialog Boxes
- Network Route........................................................ 206
Figure 8-42:
Expert > Static Routes “Add” and “Edit” Dialog Boxes
- Host Route .............................................................. 207
Figure 9-1:
Expert > Security > Users and Groups Form............ 210
Figure 9-2:
Expert > Security > Users and Groups > “Add User”
Dialog Box ................................................................ 211
Figure 9-3:
Expert > Security > Users and Groups > “Add Group”
Dialog Box ................................................................ 212
Figure 9-4:
Expert > Security > Active Ports Sessions................ 215
Figure 9-5:
Expert > Security > Authentication .......................... 217
Figure 9-6:
Expert > Security > Authentication > AuthType Form...
................................................................................... 218
Figure 9-7:
Expert > Security > Authentication > Radius........... 220
Figure 9-8:
Expert > Security > Authentication > TACACS+ .... 221
Figure 9-9:
Expert > Security > Authentication > LDAP............ 224
BLACK BOX® CS Installation, Administration, and User’s Guide
xxi
Figure 9-10:
Expert > Administration > Time/Date ..................... 226
Figure 9-11:
Expert > Security > Authentication > Kerberos........ 227
Figure 9-12:
Expert > Security > Authentication > NIS................ 228
Figure 9-13:
Expert > Security > Security Profile........................ 228
Figure 9-14:
Expert > Physical Ports Default Factory Settings.... 232
Figure 9-15:
Security Profile and Serial Ports Configuration Alert232
Figure 9-16:
Serial Ports Protocol Incompatibility Dialog Box .... 233
Figure 9-17:
Security Advisory Dialog Box................................. 234
Figure 9-18:
Wizard > Step 1: Security Profile Form.................... 235
Figure 9-19:
Custom Security Profile Dialog Box ....................... 236
Figure 10-1:
Expert > Ports........................................................... 240
Figure 10-2:
Expert > Ports > Physical Ports................................ 241
Figure 10-3:
Expert > Ports > Physical Ports > “Modify .... Ports ”
Tab Options ............................................................... 242
Figure 10-4:
Expert > Ports > Physical Ports > General Form..... 244
Figure 10-5:
Expert > Ports > Physical Ports > Console Connection
Active Tabs................................................................ 249
Figure 10-6:
Expert > Ports > Physical Ports > Console Connection.
................................................................................... 249
Figure 10-7:
Connection Protocols > Console............................... 250
Figure 10-8:
Expert > Ports > Physical Ports > Bidirectional Telnet
Active Tabs................................................................ 250
Figure 10-9:
Expert > Ports > Physical Ports > Bidirectional Telnet
Connection ................................................................ 251
Figure 10-10: Connection Protocols > Bidirectional Telnet........... 251
Figure 10-11: Expert > Ports > Physical Ports > Terminal Server Active
Tabs ........................................................................... 252
Figure 10-12: Expert > Ports > Physical Ports > Terminal Server
Connection ................................................................ 253
Figure 10-13: Connection Protocols > Terminal Server.................. 253
Figure 10-14: Expert > Ports > Physical Ports > Modem Connection
Active Tabs................................................................ 254
Figure 10-15: Expert > Ports > Physical Ports > Modem Connection .
................................................................................... 255
Figure 10-16: Connection Protocols > Modem .............................. 255
Figure 10-17: Expert > Ports > Physical Ports > Power Management
Active Tabs................................................................ 256
Figure 10-18: Expert > Ports > Physical Ports > Power Management
Connection ................................................................ 257
Figure 10-19: Connection Protocols > Power Management............ 257
Figure 10-20: Access > Authentication Types................................. 258
Figure 10-21: Expert > Ports > Physical Ports > Serial Port Settings ...
................................................................................... 260
Figure 10-22: Expert > Ports > Physical Ports > Access Form ....... 261
Figure 10-23: Expert > Ports > Physical Ports > Data Buffering .... 266
Figure 10-24: Expert > Ports > Physical Ports > Data Buffering .... 267
Figure 10-25: Expert > Port > Physical Ports >Multi User ............. 271
Figure 10-26: Expert > Ports > Physical Ports > Power Management ..
................................................................................... 273
Figure 10-27: Expert > Ports > Physical Ports > Power Management .
................................................................................... 274
Figure 10-28: Expert > Ports > Physical Ports > Power Management >
Add Outlets Dialog Box............................................ 276
Figure 10-29: Expert > Ports > Physical Ports > Power
Management>Allow All Users ................................. 278
Figure 10-30: Expert > Ports > Physical Ports >Power Management
>Allow Users/ Groups .............................................. 278
Figure 10-31: Expert > Ports > Physical Ports > Other Form.......... 279
Figure 10-32: Expert > Ports > Virtual Ports.................................. 284
BLACK BOX® CS Installation, Administration, and User’s Guide
xxiii
Figure 10-33: Expert > Ports > Virtual Ports > New/Modify Port
Dialog Box ................................................................ 285
Figure 10-34: Expert > Applications > Connect > Serial pull-down
menu.......................................................................... 287
Figure 10-35: Expert > Ports > Virtual Ports > New/Modify Port
Dialog Box ................................................................ 287
Figure 10-36: Expert > Ports > Virtual Ports > New/Modify > Port
Names Dialog box..................................................... 289
Figure 10-37: Expert > Ports > Ports Status (Read-Only) ............... 290
Figure 10-38: Expert > Ports > Port Statistics (Read-Only)............ 291
Figure 11-1:
Expert > Administration > System Information ....... 295
Figure 11-2:
Expert > Administration > Notifications .................. 298
Figure 11-3:
Expert > Administration > Notifications > Email > Add/
Edit Dialog box ......................................................... 300
Figure 11-4:
Expert > Administration > Notifications > Pager > Add/
Edit Dialog box ......................................................... 302
Figure 11-5:
Expert > Administration > Notifications > SNMP Trap >
Add/Edit Dialog box ................................................. 305
Figure 11-6:
Expert > Administration > Time/Date ...................... 307
Figure 11-7:
Expert > Administration > Time/Date > NTP Enable308
Figure 11-8:
Expert > Administration > Boot Configuration........ 309
Figure 11-9:
Expert > Administration > Backup Config............... 312
Figure 11-10: Expert > Administration > Backup Config > Storage
Device ....................................................................... 314
Figure 11-11: Expert > Administration > Upgrade Firmware......... 316
Figure 11-12: Expert > Administration > Reboot............................ 318
Figure 11-13: Expert > Administration > Online Help.................... 319
T To check Java Plug-in Support in the Browser..........................................35
T To Install JRE Version 1.4.2 or later and Register the Plug-in..................35
T To rack-mount CS, perform the following steps: ......................................37
T To Make an Ethernet Connection ..............................................................38
T To Connect Devices to Serial Ports ...........................................................38
T To Connect to the Console Port.................................................................39
T To Power on the CS...................................................................................39
T To Turn Power On Connected Devices .....................................................40
T To Log Into CS Through the Console........................................................40
T To Change the root password ....................................................................41
T To Use the wiz Command to Configure Network Parameters ..................42
T To Select a Security Profile .......................................................................45
T To Use a Dynamic IP Address to Access the Web Manager.....................47
T To Use the Default IP Address to Access the Web Manager ....................47
T To Install a PCMCIA Card ........................................................................48
T To Remove a PCMCIA Card.....................................................................48
T To Configure a PCMCIA Card..................................................................49
T To Daisy-Chain AlterPath PMs to the CS .................................................50
T Logging in to the Web Manager...............................................................52
T To Use Telnet to Connect to a Device Through a Serial Port ...................57
T To Close a Telnet Session..........................................................................57
T To Use SSH to Connect to a Device Through a Serial Port ......................58
T To Close an SSH Session...........................................................................58
T To Change Your Password ........................................................................65
T To Log Into the Web Manager...................................................................72
T To Select or Configure a Security Profile..................................................84
T To configure the Network Settings............................................................89
T To Set Parameters for All Serial Ports.......................................................92
T To Add a User............................................................................................96
T To Delete a User ........................................................................................97
T To Change a Password...............................................................................97
T To Configure Data Buffering...................................................................102
T To Add a Syslog Server...........................................................................104
T To Delete a Syslog Server........................................................................105
T To Connect to the CS...............................................................................121
T To Connect to a Device Through a Serial Port........................................122
T To View Status, Lock, Unlock, Rename, or Cycle Power Outlets..........125
T To View and Reset IPDU Information ....................................................128
T To Configure Users to Manage Power Outlets on IPDUs.......................130
T To Specify Names, Alarms, Syslogging, and Over Current Protection for
IPDUs.......................................................................................................132
T To Download AlterPath PM Software From BLACK BOX® ................134
T To Upgrade Software on an AlterPath PM..............................................135
T To Power On or Power Off a Group of Outlets in the Same Power State139
T To Power On or Power Off a Group of Outlets in Different Power States ...
..................................................................................................................139
T To Lock or Unlock a Group of Outlets in the Same Power State............140
T To Lock or Unlock a Group of Outlets in Different Lock States ............140
T To Turn the Power of a Group of Outlets Off and On Again..................140
T To Delete, Add, or Edit an IPMI Device to Enable or Disable IPMI Power
Management.............................................................................................144
T To Manage Power on an IPMI Device ....................................................145
T To Configure a Serial Port for IPDU or IPMI Power Management ........145
T To Configure a User for IPDU Power Management While Connected To a
Serial Port.................................................................................................147
T To enable IPMI Power Management of an IPMI device connected to the
currently-selected port .............................................................................148
T To Create a Menu for a Local Computer Terminal .................................150
BLACK BOX® CS Installation, Administration, and User’s Guide
xxvii
T To Configure Host Settings [Expert].......................................................157
T To Configure Syslogging for Serial Ports and Specify Message Filtering ....
..................................................................................................................160
T To Configure a PCMCIA Card................................................................162
T To Configure a Modem PCMCIA Card...................................................166
T To Configure an ISDN PCMCIA Card...................................................167
T To Configure a GSM PCMCIA Card ......................................................170
T To Configure an Ethernet PCMCIA Card ...............................................172
T To Configure a Compact Flash PCMCIA Card or a PCMCIA Hard Disk
Drive ........................................................................................................173
T To Configure a Wireless LAN PCMCIA Card........................................175
T To Configure a CDMA PCMCIA Card...................................................177
T To Eject a PCMCIA Card From the Card Slot ........................................178
T To Configure VPN...................................................................................182
T To Configure SNMP................................................................................186
T To Add a Chain........................................................................................201
T To Edit a Chain........................................................................................201
T To Add a Rule..........................................................................................202
T To Edit a Rule..........................................................................................203
T To Define the CS’s IP Address and Hostname........................................204
T To Configure Static Routes [Expert] .......................................................207
T To Add a User..........................................................................................212
T To Delete a User or Group.......................................................................213
T To Change a User’s Password .................................................................213
T To Add a Group .......................................................................................213
T To Modify a Group..................................................................................214
T To View, Kill, or Refresh Active User Sessions .....................................216
T To Configure the CS Login Authentication Method ...............................218
T To Configure a RADIUS Authentication Server.....................................220
T To Configure a TACACS+ Authentication Server..................................221
T To Configure an LDAP Authentication Server .......................................223
T To Configure a Kerberos Authentication Server .....................................225
T To Configure a NIS Authentication Server .............................................227
T To Select or Configure a Security Profile................................................233
T To Select One or More Serial Ports.........................................................242
T To Enable or Disable Serial Ports...........................................................243
T To Configure a Serial Port Connection Protocol for a Console Connection.
..................................................................................................................248
T To Configure a Serial Port Connection Protocol for a Bidirectional Telnet..
..................................................................................................................250
T To Configure a Serial Port Connection Protocol for a Terminal Server..252
T To Configure a Serial Port Connection Protocol for an External Modem.....
..................................................................................................................254
T To Configure a Power Management Protocol for an IPDU.....................256
T To Associate an Alias to a Serial Port .....................................................259
T To Configure Serial Port Settings to Match the connected devices.........259
T To Configure User Access to Serial Ports ...............................................263
T To Configure a Serial Port Login Authentication Method ......................265
T To Configure Data Buffering for Serial Ports..........................................269
T To Configure Multiple Sessions and Port Sniffing for One or More Serial
Ports .........................................................................................................272
T To Configure a Serial Port for IPDU or IPMI Power Management ........276
T To Configure a User for IPDU Power Management While Connected To a
Serial Port.................................................................................................278
T To Configure TCP Port Number, STTY Options, Break Interval, and the
Login Banner for a Serial Port Connected to a Console..........................281
T To Configure Terminal Server Connection Options................................282
T To Cluster CS Units or Modify Cluster Configuration............................287
T To Assign Names to Slave ports in the Cluster .......................................288
T To View System Information...................................................................297
T To Choose a Method for Sending Notifications for Serial Port
Data Buffering Events..............................................................................299
T To Configure a Trigger for Email Notification for Serial Ports ..............301
T To Configure a Trigger for Pager Notification for Serial Ports...............303
T To Configure a Trigger for SNMP Trap Notification for Serial Ports ....306
T To Configure a Trigger for Serial Port Alarm Notification.....................306
T To Manually Set the Time and Date........................................................308
T To Configure Time and Date Using an NTP Server................................308
T To Configure CS Boot .............................................................................311
BLACK BOX® CS Installation, Administration, and User’s Guide
xxix
T To Back Up or Restore the Configuration Files using an FTP Server.....314
T To Back Up or Restore the Configuration Files using a Storage Device 315
T To Upgrade the CS’s firmware................................................................317
T To Reboot the CS.....................................................................................318
T To Configure the Online Help Path .........................................................319
Before You Begin
This installation, administration, and user’s guide provides background
information and procedures for installing, configuring, and administering the
BLACK BOX® Advanced Console Server and for accessing connected
servers and other connected devices.
Audience
This manual is intended for installers and system administrators of the CS and
for users who may be authorized to connect to devices, to manage power
through the CS, and to monitor the CS’s temperature.
This document describes configuration, administration, and use of the CS
only. It does not describe how to set up and administer other external services
or servers that the CS may access for authentication, system logging, IPMI
control, SNMP notifications, data logging, file sharing, or other purposes.
This document assumes that users who are authorized to connect to servers
and other devices through the CS already know how to use the connected
devices.
Document Organization
The document contains the following chapters:
1: Introduction
An overview of the features of the Advanced Console
Server and necessary prerequisite information for
understanding the rest of the information in this
guide.
2: Installation and Configuration
A list of tasks for installing and configuring the
Advanced Console Server and connecting devices,
with pointers to the needed background information
and procedures.
Before You Begin
2
3: Web Manager for Regular Users
Describes how authorized users use the Web
Manager to access devices that are connected to ports
on the CS.
4: Web Manager for Administrators
Explains how the CS administrator uses the Web
Manager to add and delete users, define port access,
and perform other common administration tasks.
5: Configuring CS in Wizard Mode
Describes the 6-step procedure to configure the
Advanced Console Server in Wizard mode. Selecting
a Security Profile, configure network settings,
configure serial ports and access, and configure
settings such as data buffering and system logging.
6: Configuring the CS in Expert Mode
Provides an introduction to the Expert mode.
Describes the forms in each section, and provides a
mapping to each form with a link to the desired
section.
7: Applications Menu & Forms
Provides an overview of each form associated with
the “Applications” menu, describes the functionality
of the individual elements in each form, and provides
step-by-step configuration procedures.
8: Network Menu & Forms
Provides an overview of each form associated with
the “Network” menu, describes the functionality of
the individual elements in each form, and provides
step-by-step configuration procedures.
9: Security Menu & Forms
Provides an overview of each form associated with
the “Security” menu, describes the functionality of
the individual elements in each form, and provides
step-by-step configuration procedures.
BLACK BOX® CS Installation, Administration, and User’s Guide
3
Related Documents
10: Ports Menu & Forms
Provides an overview of each form associated with
the “Ports” menu, describes the functionality of the
individual elements in each form, and provides step-
by-step configuration procedures.
11: Administration Menu & Forms
Provides an overview of each form associated with
the “Administration” menu, describes the
functionality of the individual elements in each form,
and provides step-by-step configuration procedures.
Appendices
Appendix A provides hardware specifications, and
Appendix B details safety information.
Index
Provides a way to look up terms. In the online
version of this manual, clicking the terms in the index
brings you to where they are used in the manual.
Related Documents
The following document for the BLACK BOX® Advanced Console Server is
shipped with the product.
•
Advanced Console Server Quick Start Guide (hard-copy)
Typographic and Other Conventions
The following table describes the typographic conventions used in BLACK
BOX® manuals.
Table v-1: Typographic Conventions
Typeface
Meaning
Example
Links
Hypertext links or URLs
Go to:
http://
www.blackbox.com
Before You Begin
4
The following table describes other terms and conventions.
BLACK BOX® firmware Upgrades
BLACK BOX® offers periodic firmware upgrades for the Advanced Console
Server. These upgrades are available free of charge to current BLACK BOX®
customers. Visit ftp://ftp.blackbox.com/lan/Term-Servers/ to download the
latest firmware.
See “Upgrade Firmware” on page 313 for instructions on how to upgrade the
firmware on your Advanced Console Server.
Emphasis
Titles, emphasized or new words or
terms
See the Advanced
Console Server Quick
Start.
Filename or
Command
Names of commands, files, and
directories; onscreen computer
output.
Edit the pslave.conf
file.
User type
What you type in an example,
compared to what the computer
displays
[root] ifconfig
eth0
Table v-2: Other Terms and Conventions
Term or Convention
Meaning
Examples
Hot keys
• When hot keys are shown
with a plus (+) between
two or three keys means
that they must be pressed
at the same time.
• Pressing Ctrl+p
brings up the IPMI
power management.
Navigation shortcuts
Shortcuts use the “greater
than” symbol (>) to
indicate how to navigate to
Web Manager forms.
Go to Port > Physical
Ports> Modify Selected
Ports > Power
Management
Table v-1: Typographic Conventions
Typeface
Meaning
Example
This chapter introduces the Advanced Console Server family of advanced
console servers, provides an overview of its features, and briefly describes the
features for understanding the information and procedures in the rest of this
manual.
Overview
Page 6
Advanced Console Server Models and Configurations
Page 6
Connectors on the Advanced Console Server
Page 8
Methods of Accessing CS and Connected Devices
Page 8
Web Manager
Page 9
Prerequisites for Using the Web Manager
Page 9
Types of Users
Page 10
Security Features
Page 10
Authentication
Page 11
VPN
Page 13
Packet Filtering
Page 13
SNMP
Page 20
Notifications, Alarms, and Data Buffering
Page 21
The Advanced Console Server is a 1U device that serves as a single access
point for using and administering servers and other devices. The following
figure shows the front of the CS with its two PCMCIA card slots, and the back
of a LS1032A with its Serial, Ethernet, and Console ports.
Figure 1-1: LS1032A Front and back with PCMCIA Card Slots
Product Models and Configurations
The following table shows the available configurations. See Appendix A for
hardware specifications.
Administering Users of Connected Devices
Page 22
Power Management
Page 23
Table 1-1: Model Numbers and Configuration Options
Model Number
Serial Ports
LS1001A
1
LS1004A
4
BLACK BOX® CS Installation, Administration, and User’s Guide
7
Product Models and Configurations
The following figure illustrates the BLACK BOX® family of advanced
console servers.
Figure 1-2: BLACK BOX® CS family of Advanced Console Servers
LS1008A
8
LS1016A
16
LS1032A
32
LS1048A
48
Table 1-1: Model Numbers and Configuration Options
Model Number
Serial Ports
Connectors on the BLACK BOX® CS
The following figure depicts the connectors on the back of a LS1008A.
Figure 1-3: LS1008A Connectors
The number of serial ports and power supplies depends on the model, see
table 1-1 for model numbers and configurations options.
Accessing CS and Connected Devices
You can access CS and the connected servers or devices locally or remotely
using any of the following methods.
•
Using the Web Manager through LAN/WAN IP networks.
•
Using a modem, ISDN, GSM, or CDMA optional PCMCIA card.
•
Using the Web Manager you can login and launch a console session such
as Telnet or SSH to connect to the console of devices that are connected to
the CS’s serial ports.
•
By connecting a computer running a terminal emulation program, an CS
administrator can log into the CS box and enter commands in the CS shell
or use the Command Line Interface (CLI) tool.
Note: Only one user logged in as “root” or “admin” can have an active CLI or Web
Manager session. A second user who connects through the CLI or the Web
Manager as the “root” or “admin” has a choice to abort the session or close the
other user’s session.
Serial Ports
Ethernet Port
Console Port
Power Supply
BLACK BOX® CS Installation, Administration, and User’s Guide
9
Web Manager
Note: If there are cron jobs running through automated scripts, a “root” or “admin”
user login can cause the automated cron jobs to fail. Make sure that the users
with administrative privileges are aware of this.
Web Manager
CS administrators perform most tasks through the Web Manager either locally
or from a remote location. The Web Manager runs in a browser and provides a
real-time view of all the equipment that is connected to the CS.
The CS administrator can use the Web Manager to configure users and ports.
An authorized user can access connected devices through the Web Manager to
troubleshoot, maintain, recycle power, and reboot connected devices.
Access to the Web Manager is through one of the following ways:
•
Through the IP Network.
•
Through a dial-in or callback connection with one of the following:
•
An optional external modem connected to one of the serial ports.
•
A modem on an optional PCMCIA modem card.
•
An optional CDMA, GSM, or ISDN card.
Prerequisites for Using the Web Manager
The prerequisites described in this section must be complete before anyone
can access the Web Manager. If you have questions about any of the following
prerequisites, contact your system or network administrator.
•
Basic network parameters must be defined on the CS so the Web Manager
can be launched over the network.
See “Performing Basic Network Configuration Using the wiz Command”
on page 38.
•
The IP address of the CS must be known.
When DHCP is enabled, a leased IP address is assigned to CS. The leased
IP address may change every time CS reboots. Therefore, an additional
step needs to be taken to find out the dynamically-assigned IP address
before the Web Manager can be accessed through the browser. Following
are three ways to find out the dynamically-assigned IP address:
Make an inquiry to the DHCP server on the subnet that the CS resides,
using the MAC address (The MAC address is labeled at the bottom of
the CS).
•
Connect to CS remotely using Telnet or SSH and use the ifconfig
command.
•
Connect directly to the CS and use the ifconfig command through
a terminal emulator application.
•
A user account must be defined on the Web Manager.
By default, the “admin” has an account on the Web Manager. An
administrator can add regular user accounts to grant access to the
connected servers or devices using the Web Manager.
Types of Users
CS supports the following user account types:
•
The “root” user who can manage the CS and its connected devices. The
“root” user performs the initial network configuration. Access privileges
are full read/write and management.
Note: It is strongly recommended to change the default password “bb” before
setting up the CS for secure access to the connected servers or devices.
•
Users who can be part of an “Admin” group with administrative
privileges. This may be a regular user who can perform the same tasks as
an administrator.
•
Regular users who can access the connected devices through the serial
ports they are authorized for. Regular users have limited access to the Web
Manager features.
Security
The Advanced Console Server includes a set of security profiles that consists
of predefined parameters to control access to CS and its serial ports. This
feature provides more control over the services that are active at any one time.
As an additional security measure, all serial ports are disabled by default,
which allows the administrator to enable and assign individual ports to users.
See “Security Profiles” on page 226 for detailed information and procedures.
BLACK BOX® CS Installation, Administration, and User’s Guide
11
Authentication
Authentication
CS supports a number of authentication methods that can help the
administrator with the user management. Authentication can be performed
locally or with a remote server, such as RADIUS, TACACS+, LDAP, or
Kerberos. An authentication security fallback mechanism is also employed,
should the negotiation process with the authentication server fails. In such
situations, the CS follows an alternate defined rule when authentication server
is down or does not authenticate the user.
The following table lists the supported authentication methods.
Table 1-2: CS Supported Authentication Methods
Authentication Type
Definition
None
No authentication.
Kerberos
Authentication is performed using a Kerberos
server.
Kerberos/Local
Kerberos authentication is tried first, switching
to Local if unsuccessful.
KerberosDownLocal
Local authentication is performed only when
the Kerberos server is down.
LDAP
Authentication is performed against an LDAP
database using an LDAP server.
LDAP/Local
LDAP authentication is tried first, switching to
Local if unsuccessful.
LDAPDownLocal
Local authentication is performed only when
the LDAP server is down.
Local
Authentication is performed locally. For
example using the /etc/passwd file.
Local/Radius
Authentication is performed locally first,
switching to Radius if unsuccessful.
Authentication is performed locally first,
switching to TACACS+ if unsuccessful.
Local/NIS
Authentication is performed locally first,
switching to NIS if unsuccessful.
NIS
NIS authentication is performed.
NIS/Local
NIS authentication is tried first, switching to
Local if unsuccessful.
NISDownLocal
Local authentication is performed only when
the NIS server is down.
Radius
Authentication is performed using a Radius
authentication server.
Radius/Local
Radius authentication is tried first, switching to
Local if unsuccessful.
RadiusDownLocal
Local authentication is performed only when
the Radius server is down.
TACACS+
Authentication is performed using a
TACACS+ authentication server.
TACACS+/Local
TACACS+ authentication is tried first,
switching to Local if unsuccessful.
TACACS+DownLocal
Local authentication is tried only when the
TACACS+ server is down.
Authentication Type
Definition
BLACK BOX® CS Installation, Administration, and User’s Guide
13
VPN
VPN
The CS administrator can set up VPN connections to establish an encrypted
communications between the CS and a host on a remote network. The
encryption creates a security tunnel for a dedicated communications.
You can use the VPN features on CS to create the following types of
connections:
•
A secure tunnel between CS and a gateway at a remote location so every
machine on the subnet at the remote location has a secure connection with
CS.
•
Create a secure tunnel between CS and a single remote host
To set up a security gateway, you can install IPSec on any machine that does
networking over IP, including routers, firewall machines, application servers,
and end-user machines.
The ESP and AH authentication protocols are supported. RSA Public Keys
and Shared Secret are also supported.
For detailed information and procedures to configure a VPN connection, see
“VPN Connections” on page 176.
Packet Filtering on CS
The CS administrator can configure the box to filter packets like a firewall. IP
filtering is controlled by chains and rules.
Structure of IP Filtering
The Firewall Configuration form in the Web Manager is structured on two
levels:
•
The view table of the “Firewall Configuration” form which contains a list
of chains.
•
The chains which contain the rules that control filtering.
A chain is a named profile that includes one or more rules that define the
following:
•
A set of characteristics to look for in a packet
•
What to do with any packet that has all the defined characteristics
The CS filter table contains a number of built-in chains. The CS administrator
can define additional chains and can edit the built-in chains. The built-in
chains are referenced according to the type of packet they handle as shown in
the following list:
•
INPUT - For incoming packets.
•
FORWARD - For packets being routed through CS.
•
OUTPUT - For outgoing packets.
As defined in the rules for the default chains, all input and output packets, and
packets being forwarded are accepted.
Rule
Each chain can have one or more rules that define the following:
•
The packet characteristics being filtered.
The packet is checked for characteristics defined in the rule. For example,
a specific IP header, input and output interfaces, TCP flags and protocol.
•
What to do when the packet matches the rule.
The packet can be handled according to a specified target policy such as
accepted, dropped, returned, logged, or rejected.
When a packet is filtered, its characteristics are compared against the rules
one-by-one. All defined characteristics must match. If no rules are found then
the default action for that chain is applied.
Administrators can do the following to specify packet filtering:
•
Add a new chain and specify rules for that chain
•
Add new rules to existing chains
•
Edit a built-in chain or delete the built-in chain rules
BLACK BOX® CS Installation, Administration, and User’s Guide
15
Packet Filtering on CS
Add Rule and Edit Rule Options
When you add or edit a rule you can define any of the options described in the
following table.
You can flag any of the above elements with inverted so that the target action
is performed on packets that do not match any of the criteria specified in that
line. For example, if you select DROP as the target action, specify “Inverted”
for a source IP address, and do not specify any other criteria in the rule, any
Table 1-3: Filter Options for Packet Filtering Rules
Filter Options
Description
Source IP and Mask
Destination IP and Mask
If you specify a source IP, incoming packets are filtered for
the specified IP address. If you specify a destination IP,
outgoing packets are filtered for the specified IP address.
If you fill in a source or destination mask, incoming or
outgoing packets are filtered for IP addresses from the
subnetwork in the specified netmask.
Protocol
You can select a protocol for filtering from one of the
following options:
• ALL
• Numeric Protocol Options
• TCP Protocol Options
• UDP Protocol Options
• ICMP Protocol Options
Input Interface
The input interface (ethN) used by the incoming packet.
Output Interface
The output interface (ethN) used by the outgoing packet.
Fragments
The types of packets to be filtered:
• All packets
• 2nd, 3rd... fragmented packets
• Non-fragmented and 1st fragmented packets
packets arriving from any other source IP address than the one specified are
dropped.
Numeric Protocol Options
If you select Numeric as the protocol when specifying a rule, you need to
specify the desired number.
TCP Protocol Options
If you select TCP as the protocol when specifying a rule, you can define the
following options.
Table 1-4: TCP Protocol Packet Filtering Options
Field/Menu Option
Definition
Source Port
- OR -
Destination Port
You can specify a source or destination port number for filtering in
the “Source Port” or “Destination Port” field. You can also specify
a range so that TCP packets are filtered for any port number within
the range.
TCP Flags
Specifying any of the flags: “SYN” (synchronize), “ACK”
(acknowledge), “FIN” (finish), “RST” (reset), “URG” (urgent),
“PSH” (push), and one of the “Any,” “Set,” or “Unset” conditions,
filters TCP packets for the specified flag and the selected
condition.
BLACK BOX® CS Installation, Administration, and User’s Guide
17
Packet Filtering on CS
UDP Protocol Options
When you select UDP as a protocol when specifying a rule, you can select the
UDP options defined in the following table.
ICMP Protocol Options
When you select ICMP as a protocol when specifying a rule, you can select
the following ICMP options.
•
all
•
echo-reply
•
destination-unreachable
•
network-unreachable
•
host-unreachable
•
protocol-unreachable
•
port-unreachable
•
fragmentation-needed
•
source-route-failed
•
network-unknown
•
host-unknown
•
network-prohibited
•
host-prohibited
•
TOS-network-unreachable
•
TOS-host-unreachable
•
communication-prohibited
•
host-precedence violation
Table 1-5: UDP Protocol Packet Filtering Options
Field
Definition
Source Port
- OR -
Destination Port
Specify a source or destination port number for filtering in the
“Source Port” or “Destination Port” field.
You can specify a source or destination port number for filtering in
the “Source Port” field. You can also specify a second number so
that UDP packets are filtered for any port number within the range.
The “Target” is the action to be performed on an IP packet that matches all the
criteria specified in a rule. The target actions are:
•
ACCEPT
•
DROP
•
RETURN
•
LOG
•
REJECT
BLACK BOX® CS Installation, Administration, and User’s Guide
19
Packet Filtering on CS
If the “LOG” and “REJECT” targets are selected, additional options are
available.
The following table describes the options for the “LOG” Target.
Table 1-6: LOG Target Action Options
The following list shows the options for the REJECT Target:
•
icmp-net-unreachable
•
icmp-host-unreachable
•
icmp-port-unreachable
•
icmp-proto-unreachable
•
icmp-net-prohibited
•
icmp-host-prohibited
•
echo-reply
•
tcp-reset
Options
Definition
Log Level
emerg
alert
crit
err
warning
notice
info
debug
Log Prefix
The prefix to use in the log entry.
TCP Sequence
Includes the TCP sequence in the log.
TCP Options
Includes TCP options in the log.
IP Options
Includes IP options in the log.
Firewall Configuration Procedures
The following table has links to the procedures for defining packet filtering
using the Web Manager.
SNMP
The CS administrator can activate Simple Network Management Protocol
(SNMP) agent that resides on the CS so that the SNMP agent sends
notifications about significant events or traps to an SNMP management
application. The CS SNMP agent supports SNMP v1/v2 and v3.
The following table shows the tasks related to administering SNMP on the CS
and provides links to where they are documented.
To Add a Chain
Page 199
To Edit a Chain
Page 199
To Add a Rule
Page 200
To Edit a Rule
Page 201
To Configure SNMP
See “To Configure SNMP”
on page 184.
To configure one or more serial ports
to send SNMP traps.
See “SNMP Trap
Notifications Entry” on page
302
BLACK BOX® CS Installation, Administration, and User’s Guide
21
Notifications, Alarms, and Data Buffering
Notifications, Alarms, and Data Buffering
The CS administrator can setup logging, notifications, and alarms to alert
administrators about problems. System generated messages on CS and the
connected servers or devices can be sent to syslog servers for handling. The
administrator can also configure data buffering to store data from
communication on serial ports for monitoring.
Data from communication with serial-connected consoles can be stored:
•
Locally in the CS’s flash memory, or
•
Remotely either on an NFS server or a syslog server.
Syslog Servers
Messages about the CS and connected servers or devices can be sent to a
central logging servers, called syslog servers. Console data from devices
connected to serial ports can be stored in data buffer files on syslog servers.
By default logging and data buffering are not done.
Prerequisites for Logging to Syslog Servers
Before configuring syslogging, the CS administrator must ensure that syslog
server is pre-configured with a public IP address, and it is accessible from CS.
The CS administrator must be able to obtain the following information from
the syslog server’s administrator.
•
The IP address of the syslog server
•
The facility number for messages coming from the CS.
Facility numbers are used on the syslog server for handling messages
generated by multiple devices.
Facility Numbers for Syslog Messages
Each syslog server has seven local facility numbers available for its
administrator to assign to different devices or groups of devices at different
locations. The available facility numbers are Local0 through Local7.
An Example of Using Facility Numbers
The syslog system administrator sets up a server called “syslogger” to handle
log messages from two CS boxes. One CS is located in São Paulo, Brazil, and
the other in Fremont, California. The syslog server’s administrator wants to
aggregate messages from the São Paulo CS into the local1 facility, and to
aggregate messages from Fremont CS into the local2 facility.
On “syslogger” the system administrator has configured the system logging
utility to write messages from the local1 facility to the /var/log/
saopaulo-config file and the messages from the local2 facility to the /
var/log/fremont-config file. If you were in Fremont and identifying the
syslog server using the Web Manager, according to this example, you would
select the facility number Local2 from the “Facility Number” pull-down menu
on the Syslog form.
Administering Users of Connected Devices
This sections provides a list of task that an CS administrator can perform to
enable access to connected devices.
Planning Access to Connected Devices
The CS administrator needs to perform specific tasks to setup and configure
user access to the connected servers, IPDUs, or other devices. An advanced
planning can minimize issues that may arise during software configuration.
Some of the planning steps includes the following:
•
Create a list of servers or devices to connect to the serial ports.
•
Create a list of users with the type of access each user requires.
•
Create a matrix of users and required access to each connected server or
device.
•
Create meaningful aliases to assign to port numbers.
•
List all devices that need to be connected to IPDUs and the users who
need to access them.
BLACK BOX® CS Installation, Administration, and User’s Guide
23
CS and Power Management
Configuring Access to Connected Devices
During hardware installation of CS, the installer connects the servers, devices,
and any IPDUs to the serial ports.
During software configuration, the CS administrator performs the common
tasks listed in the following table.
CS and Power Management
CS enables users who have power management permissions to power off,
power on, and reboot devices. The CS offers the following power
management options:
•
Remote power management of servers that have IPMI controllers. The
CS's implementation of the Intelligent Platform Management Interface
(IPMI) protocol lets authorized users manage power for servers that have
embedded IPMI controllers. IPMI servers do not need to be connected to
the CS because their IPMI controllers respond to out-of-band IPMI
Table 1-7: Tasks for Configuring Access to Connected Devices
Task
Where documented
Configure a serial port connection protocol
for a console connection
Page 246
Configure user access to serial ports.
Page 261
Configure a serial port for IPDU or IPMI
power management
Page 274
Configure a user for IPDU power
management
Page 276
commands. Authorized users can also perform IPMI power management
of serially-connected devices. The CS uses IPMI V1.5.
•
Remote power management of devices that are plugged into an IPDU that
is connected to CS
•
The intelligent power distribution unit (IPDU) can be an AlterPath PM
connected to any serial port. Up to 128 IPDU outlets can be daisy-
chained.
•
The diagram below shows a typical setup of the CS and an AlterPath PM
unit.
Figure 1-4: IPDU Integration With CS
Configuring Power Management
Administrators commonly perform power management through the Web
Manager, to assign power management permissions to users, configure IPMI
devices, and configure ports for power management.
BLACK BOX® CS Installation, Administration, and User’s Guide
25
CS and Power Management
The following table list the tasks for power management and where they are
described.
Configuring Ports for Power Management by Authorized Users
Administrators of connected devices who have power management
permissions can do power management while connected by using a “hot key”
that brings up a power management screen.
For IPMI power management the default hot key is Ctrl+p. For IPDU power
management the default hot key is Ctrl+Shift+I.
Configuring Ports for Power Management Using the CLI
CS administrators can use the CLI command with the config ipmi
options to manage power on IPMI devices while logged into the CS with
administrative rights. The ipmitool command is documented in the
BLACK BOX® Advanced Console Server Command Reference Guide.
Table 1-8: Tasks for Configuring Power Management
Task
Where Documented
Configure users to manage power on IPDUs
“To Configure a User for IPDU Power
Management While Connected To a Serial
Port” on page 276
Identify servers for IPMI power
management
“To Delete, Add, or Edit an IPMI Device to
Enable or Disable IPMI Power
Management” on page 142
Configure ports for power management by
authorized users
“To Configure a Serial Port for IPDU or
IPMI Power Management” on page 274.
Options for Managing Power
The sections listed below describe the different ways that the authorized users
can perform power management through CS.
•
From forms in the Web Manager
•
From a power management screen while logged into a device
•
From the command line while logged into CS
An authorized user with administrative privileges can perform IPDU and
IPMI power management. A Regular User with permissions to the connected
devices can perform IPDU power management.
Power Management Through the Web Manager
Users with power management permissions can perform power management
through the Web Manager. The Web Manager menu includes the two power
management options listed in the following table, with links to where each is
documented.
Power Management from the CS Command Line
CS administrators can use the ipmitool command to manage power on
IPMI devices while logged into the CS with administrative rights. The
ipmitool command is documented in the BLACK BOX® Advanced
Console Server Command Reference Guide.
Table 1-9: Power Management Options in the Web Manager
Form Name
Where Documented
IPDU Power Mgmt
• “IPDU Power Mgmt.” on page 120
• “To View Status, Lock, Unlock, Rename, or Cycle
Power Outlets” on page 123
IPMI Power Mgmt
• “IPMI Power Management” on page 139
• “To Delete, Add, or Edit an IPMI Device to Enable or
Disable IPMI Power Management” on page 142
• “To Manage Power on an IPMI Device” on page 143
Installation and Configuration
This chapter covers the topics listed in the following table.
The following figure illustrates an example of an CS configured with
connected devices.
Shipping Box Contents
Page 28
Important Pre-Installation Requirements
Page 32
Basic Installation Procedures
Page 34
Other Methods of Accessing the Web Manager
Page 45
Installing PCMCIA Cards
Page 46
Connecting AlterPath PM IPDUs
Page 47
Installation and Configuration
28
Figure 2-1: CS Setup Example
Shipping Box Contents
The shipping box contains the CS along with the items shown in Table 2-1
and Table 2-2 for CS4 through CS48, and CS1 respectively. The entry for each
part provides an illustration, its part number, description, and purpose. You
can use checkboxes to check off each item, and you can use the part numbers
from this table to reorder any of the parts.
The list is numbered for internal cross-referencing among descriptions within
this table.
Table 2-1: Shipping Box Contents for LS1004A - LS1048A
R
Item
Description
Purpose
1.
Documentation CD
PDF copies of this guide.
BLACK BOX® CS Installation, Administration, and User’s Guide
29
Shipping Box Contents
3.
Power cable.
To connect the CS to a power source.
4.
RJ45 to DB25F
crossover adapter
To connect the console port to a computer
that has a DB-25 male connector.
5.
RJ45 to DB25M
crossover adapter
To connect the console port to a computer
that has a DB-25 female connector.
6.
RJ45 to DB9F
crossover adapter
To connect the console port to a computer
that has a DB-9 connector.
7.
Sun/Netra crossover
adapter
To connect the console port to a Sun Netra
server, or other devices with the same
pinout configuration.
8.
RJ45 to RJ45 7ft.
CAT5 cable
Use for the following:
• To connect a device or an IPDU to a
serial port.
• To connect an Ethernet port to the LAN.
• To connect a terminal to a console port.
R
Item
Description
Purpose
Installation and Configuration
30
9.
RJ45 to DB25M
straight-thru cable
Use for modems and other DCE devices.
10.
DB25F Loopback
Use to test and diagnose serial ports.
11.
2 - Mounting
brackets with
10 - screws (2 spares)
Use to mount the CS to a rack or cabinet.
R
Item
Description
Purpose
BLACK BOX® CS Installation, Administration, and User’s Guide
31
Shipping Box Contents
Table 2-2: Shipping Box Contents for LS1001A
R
Item
Description
Purpose
1.
Documentation CD
PDF copies of this guide.
3.
RJ45 to DB9F
crossover adapter
To connect the console port to a computer
that has a DB-9 connector.
4.
DB25F Loopback
Use to test and diagnose serial ports.
5.
3.5mm Block Plug
Use to establish RS-485 connection.
6.
DB9F to DB25M
adapter
Use to convert serial port connectors.
7.
Bumpon Protect
Pads
Adhesive pads to protect and stabilize CS1.
Installation and Configuration
32
Important Pre-installation Requirements
Before installing and configuring CS, ensure that you have the following:
•
Root Access on your local UNIX machine in order to use the serial ports.
•
An appropriate Terminal application for your operating system.
•
IP address, DNS, Network Mask, and Gateway addresses of your server
or terminal, the CS, and the machine that CS is connected to.
•
A web browser that supports the CS Web Manager, such as Netscape,
Internet Explorer 6.0, Firefox, or Mozilla.
•
Java 2 Runtime Environment (JRE) version 1.4.2 or later. J2RE can be
downloaded from http://java.com.
8.
RJ45 to RJ45 7ft.
CAT5 cable
Use for the following:
• To connect a device or an IPDU to a
serial port.
• To connect an Ethernet port to the LAN.
• To connect a terminal to a console port.
9.
DB9F to DB25F
crossover cable
To connect the RS-232 serial port to a
computer that has a DB-25 male connector.
10.
Power Supply
+5V/2.5A
Power supply.
11.
Power Cable
6ft. 2-Pin
To connect the CS to a power source.
BLACK BOX® CS Installation, Administration, and User’s Guide
33
Important Pre-installation Requirements
Java Plug-In Requirement for Serial Port Access
The JRE version 1.4.2 or later must be installed for a user to be able to access
a serial port using the Java applet viewing window. After you download and
install J2RE version 1.4.2 or later, check your browser configuration to see if
the Java plug-in is configured with your browser.
T To check Java Plug-in Support in the Browser
1.
To check Internet Explorer on Windows, do the following steps.
a.
Go to Tools > Internet Options > Advanced
b. Scroll down and look for a section on Java.
c.
There should be a check box that says “Use Java 2 v1.4.2...." As
shown in the following figure.
d. If an option similar to the above figure does not appear, it means that
JRE is not installed on your system. Or, if the option appears, but the
checkbox is not enabled, this means your browser is not activated to
use the Java plug-in that came with JRE.
2.
To check Netscape or Mozilla on Windows, do the following steps.
a.
Go to Edit > Preferences >Advanced.
b. Check the “Enable Java” checkbox.
c.
To see what version of the Java plug-in is registered, do the following
steps.
i.
Go to Help > About Plug-ins.
ii.
Scroll to the Java Plug-in section.
iii. Check whether the registered Java plug-in is the same as the
version you installed.
T To Install JRE Version 1.4.2 or later and Register the Plug-in
1.
Make sure that JRE 1.4.2 or later is installed on the computer.
Installation and Configuration
34
If needed, download the JRE from http://java.com. The web site
automatically checks your configuration and installs the latest version of
JRE if one is not available.
2.
If JRE is already installed on your system and you just want to activate
your browser, do the following steps.
a.
Go to your system's Control Panel > Java Plug-in > Browser
b. Enable the browser(s) for Java Plug-in.
c.
Test your browser(s) to see if the correct Java Plug-in is being used.
Basic Installation Procedures
The following table lists the basic installation tasks in the order in which they
should be performed and shows the page numbers where the tasks are
described in more detail.
Table 2-3: CS Basic Installation Tasks
Task
Where Documented
Mount the CS
“Mounting the CS” on page 35
Make an Ethernet connection
“Making an Ethernet Connection” on page 35
Connect servers and other devices to be
managed through the CS
“Connecting Servers and Other Devices to
CS” on page 36
Make a direct (terminal) connection to
prepare CS for basic network configuration
“Making a Direct Connection to Configure the
Network Parameters.” on page 37
Power on the CS and the connected devices
“Powering on the CS and the Connected
Devices” on page 37
Perform basic network configuration
“Performing Basic Network Configuration
Using the wiz Command” on page 38
Select a security profile using the web
manager
“Selecting A Security Profile Using the Web
Manager” on page 43
BLACK BOX® CS Installation, Administration, and User’s Guide
35
Basic Installation Procedures
Mounting the CS
You can mount the CS on a wall, rack, or cabinet, or place it on a desktop or
other flat surface. Two brackets are supplied with six hex screws for attaching
the brackets to CS for mounting. See item 14 in the shipping content section.
•
If you are not mounting the CS, place the unit on a desk or table.
•
If you are rack-mounting the CS, obtain a hex screwdriver and
appropriate nuts and bolts before starting the following procedure.
T To rack-mount CS, perform the following steps:
1.
Install the brackets on to the front or back edges of the box using a screw
driver and the screws provided with the mounting kit.
2.
Mount the CS box in a secure position.
Note: To ensure safety refer to Appendix B: Safety Guidelines.
Making an Ethernet Connection
You can use the RJ-45 straight-through cable and the appropriate adapter
provided in the product box to assemble a console cable. All adapters have an
RJ-45 connector on one end and either a DB25 or DB9 male or female
connector on the other end.
brackets
Installation and Configuration
36
T To Make an Ethernet Connection
1.
Connect the RJ-45 end of the cable to the port labeled “Console” on the
CS.
2.
Connect the adapter end of the cable to the console port of your server or
device.
3.
Connect a patch cable from the CS port labeled 10/100Base-T to an
Ethernet hub or switch.
Connecting Servers and Other Devices to CS
The following sections describes the recommended preparation for
connecting servers or devices to CS.
•
Make sure the configuration on servers or devices to be connected are
completed.
•
Work with the administrator of the servers or devices to ensure all the
following prerequisites are met:
•
All devices are installed and fully configured.
•
User accounts exist for the users who need access to the server or
device.
•
If a device is to use remote authentication, make sure that the
authentication servers are installed and fully configured
•
You have obtained from the server’s administrator the information (IP
address and other method-specific information), which you need to
configure the authentication server on the CS.
T To Connect Devices to Serial Ports
Using patch cables with RJ-45 connectors and DB-9 console adapters
assemble crossover cables to connect the CS serial ports to the device’s
console port.
Note: After CS is installed make sure to specify the desired authentication method to
CS and the serial ports that each device is connected to. See “Authentication”
on page 214 for more information on configuring authentication to CS, and
“Physical Ports” on page 239 for detail information on configuring the serial
ports.
BLACK BOX® CS Installation, Administration, and User’s Guide
37
Basic Installation Procedures
Making a Direct Connection to Configure the
Network Parameters.
Perform the following steps to connect a terminal or a computer to the console
port of the CS. This procedure assumes you know how to use a terminal or
terminal emulation program.
On a PC, ensure that HyperTerminal or another terminal emulation program is
installed on the Windows operating system. On a computer running a UNIX-
based operating system, such as Solaris or Linux, make sure that a compatible
terminal emulator such as Kermit or Minicom is installed.
T To Connect to the Console Port
1.
Install and launch your serial communication software on a terminal or a
computer. For example, if you are using a PC, use HyperTerminal to
perform the initial configuration of the CS directly through your PC’s
COM port.
2.
Open HyperTerminal. Start > All Programs > Accessories >
Communications > HyperTerminal
3.
Start a New Connection session, select an available COM port, and enter
the following console parameters.
•
Bits per second: 9600 bps
•
Data bits: 8 bits
•
Parity: None
•
Stop bit: 1
•
Flow control: None
Powering on the CS and the Connected Devices
Do the following procedures in the order shown to avoid problems with
components on connected devices.
T To Power on the CS
1.
Make sure the CS’s power switch is off.
2.
Plug in the power cable.
3.
Turn the CS’s power switch(es) on.
Installation and Configuration
38
Note: If your CS model is equipped with dual power supplies, make sure you turn
both power switches on. After system initialization, a beep sound may warn if
one of the power supplies is off.
T To Turn Power On Connected Devices
•
Turn on the power switches of the connected devices only after you have
completed the physical connection to CS.
Configuring the Network Parameters
In preparation to make CS available on the network, collect the following
information from your system administrator and proceed with the network
configuration procedure.
•
Hostname
•
An IP address for CS
•
Domain name
•
DNS IP address
•
Gateway IP address
•
Network mask
•
NTP server’s IP address (if you are using a time/date server)
Performing Basic Network Configuration Using the wiz
Command
The following procedure assumes that a hardware connection is made
between the CS’s console port and the COM port of a computer.
T To Log Into CS Through the Console
From your terminal emulation application, log into the console port as
root.
CS login: root
Password: bb
BLACK BOX® CS Installation, Administration, and User’s Guide
39
Basic Installation Procedures
Note: It is strongly recommended to change the default password “bb” before
setting up the CS for secure access to the connected servers or devices.
T To Change the root password
1.
Enter the passwd command.
d. Enter a new password when prompted.
The following Security Advisory appears the first time CS is powered on, or
when the unit is reset to factory default parameters.
[root@CAS root]# passwd
New password: new_password
Re-enter new password: new_password
Password changed
Installation and Configuration
40
Figure 2-2: Security Advisory Console Message
T To Use the wiz Command to Configure Network Parameters
1.
Launch the Configuration Wizard by entering the wiz command.
Important - Security Advisory!
Console Management provides critical access to management
features of attached equipment. Please take the required precautions
to understand the potential impacts this device may have to your
SECURITY policies.
From factory, this device is configured as follows:
- single password for ROOT;
- all serial port DISABLED;
- DHCP, Telnet, SSHv1 & SSHv2 and HTTP & HTTPS enabled.
The following actions are STRONGLY recommended:
1. To change the ROOT user's password before setting up the
device.
2. That you SELECT A SECURITY PROFILE to complete the
INITIAL SETUP.
Security is dependent on Policy and is Configurable to fit in
environments with varying levels of Security. This device
provides three pre-set
Security Levels: SECURED, MODERATE and OPEN, and in
addition, the ability to set a CUSTOM Security Profile.
3. Do not leave the equipment idle WITHOUT selecting a
SECURITY PROFILE.
4. To ENABLE Serial Ports and CONFIGURE them using Web UI
or CLI.
Refer to the Quick Start Guide or the User's Guide for Security Profile
selection details and Serial Port configuration.
[root@CAS root]# wiz
BLACK BOX® CS Installation, Administration, and User’s Guide
41
Basic Installation Procedures
As shown in the sample screen below, the system brings up the
configuration wizard banner and begins running the wizard.
2.
At the prompt, enter n to change the defaults.
3.
Press Enter to accept the default hostname, otherwise enter your own
hostname.
4.
Press Enter to keep DHCP enabled, or enter “n” to specify a static IP
address for CS. By default, CS uses the IP address provided by the DHCP
server. If your network does not use DHCP, then CS will default to
192.168.160.10.
Set to defaults (y/n)[n]: n
Hostname [CAS]: fremont_branch_CS
Do you want to use DHCP to automatically
assign an IP for your system? (y/n)[y] :
Installation and Configuration
42
5.
To change the default static IP address, see your network administrator to
obtain a valid IP address.
6.
Enter the domain name.
7.
Enter the IP address for the Primary DNS (domain name) server.
8.
Enter the IP address for the gateway.
9.
Enter the netmask for the subnetwork.
The network configuration parameters appear.
10. Enter y after the prompts shown in the following screen example.
11. To confirm the configuration, enter the ifconfig command.
12. After the initial configuration proceed to the Web Manager to select a
security profile.
System IP[192.168.160.10]: CS_IP_address
Domain name[blackbox.com]: domain_name
Primary DNS Server[192.168.44.21] :
DNS_server_IP_address
Gateway IP[eth0] : gateway_IP_address
Network Mask[#] : netmask
Are all these parameters correct? (y/n)[n]: y
Do you want to activate your configurations
now? (y/n)[y]: y
Do you want to save your configuration to
Flash? (y/n)[n]: y
BLACK BOX® CS Installation, Administration, and User’s Guide
43
Basic Installation Procedures
Note: To use the Web Manager, ask your system administrator for the CS’s IP
address. CS may be set up with a static IP address at your site. By default, CS
uses the IP address provided by the DHCP server. If your network does not
use DHCP, then CS defaults to 192.168.160.10.
Selecting A Security Profile Using the Web Manager
After the initial configuration, connect to the Web Manager by entering the IP
address of the CS in a supported browser.
Note: Once you login to the Web Manager, a Security Profile must be selected in
order to further configure CS using the Web Manager. For this reason your
browser redirects to Wizard > Step1: Security Profiles.
T To Select a Security Profile
Select a pre-defined Security Profile, or define a Custom profile for specific
services. The profiles are:
•
Secured: Disables all protocols except SSHv2, HTTPS, and SSH to
Serial Ports.
•
Moderate: Enables SSHv1, SSHv2, HTTP, HTTPS, Telnet, SSH and
Raw connections to Serial Ports, ICMP, and HTTP redirection to
HTTPS.
•
Open: Enables all services, Telnet, SSHv1, SSHv2, HTTP, HTTPS,
SNMP, RPC, ICMP and Telnet, SSH and Raw connections to Serial
Ports.
•
Default: Sets the profile to the same configuration as Moderate.
•
Custom: Enable or disable individual protocols and services, and
configure access to ports.
For detailed information on Security Profiles see “Security Profiles” on page
226.
The administrator can perform the following tasks using the Web Manager.
•
Administer CS and its connected devices.
•
Configure user and group permissions.
Installation and Configuration
44
•
Access the serial ports and the connected devices.
Adding Users and Configuring Ports Using the
Web Manager
Enabling Ports and Assigning Users.
Note: From the factory, CS is configured with all serial ports disabled.
•
The administrator can add users, enable or disable the serial ports, and
select and assign specific users to individual ports. For detailed
information on managing users and ports see Appendix 9, “Security Menu
& Forms" and Appendix 10, “Ports Menu & Forms".
For additional configuration and administration options, and other important
related information, see the chapters in the CS user manual that are listed in
the following table.
Topic
Where Documented
Installation and Configuration Process.
Appendix 2, “Installation and
Configuration"
For Regular Users - How to use the Web
Manager to access servers and connected
devices.
Appendix 3, “Web Manager for Regular
Users"
Web Manager in Wizard Mode.
Appendix 5, “Configuring CS in Wizard
Mode"
Web Manager in Expert Mode.
Appendix 6, “Configuring the CS in
Expert Mode"
BLACK BOX® CS Installation, Administration, and User’s Guide
45
Other Methods of Accessing the Web Manager
Other Methods of Accessing the Web Manager
You can access the Web Manager using one of the following methods.
Note: The following methods require additional setup and configuration, which
could be specific to your site’s network configuration.
•
Using DHCP
•
Using the default IP address
T To Use a Dynamic IP Address to Access the
Web Manager
This procedure assumes that DHCP is enabled, and that you are able to obtain
the dynamic IP address that is currently assigned to CS.
1.
Mount the BLACK BOX® CS.
2.
Connect computers and other devices to be managed through the CS.
3.
Power on the CS and connected devices.
4.
Obtain the CS’s current IP address.
5.
Enter the CS’s IP address in the browser’s Address window.
6.
Login to the CS and finish configuring users and other settings using the
Web Manager.
T To Use the Default IP Address to Access the Web
Manager
The default IP address for the CS is 192.168.160.10. This procedure
assumes that you are able to temporarily change the IP address of a computer
that is on the same subnet as the CS.
1.
On a computer that resides on the same subnet as the CS, change the
network portion of the IP address of that computer to 192.168.160.
For example, you could change the computer’s IP address to
192.168.160.44. For the host portion of the IP address, you can use
any number except 10, 0, or 255.
Installation and Configuration
46
2.
Bring up a browser on the computer whose address you changed, enter the
CS’s default IP address, http://192.168.160.10 to bring up the
Web Manager, and log in.
Installing PCMCIA Cards
The front panel of the CS has two PCMCIA card slots as shown in the
following figure. You can insert and configure one card in each of the slots.
See Appendix C, “Supported PCMCIA Cards".
Figure 2-3: Front Panel PCMCIA Card Slots
T To Install a PCMCIA Card
1.
Insert the PCMCIA card into slot 1 or slot 2.
2.
Use the Web Manager to configure the PCMCIA card.
Note: A hard disk PCMCIA card is automatically mounted once it is inserted, and it
needs no configuration.
T To Remove a PCMCIA Card
Caution: Always use the Web Manager to eject a PCMCIA card. Any other method
may cause a kernel panic.
1.
Eject the card by using the Eject button on the Web Manager’s PCMCIA
Management form, Expert > Network > PCMCIA Management > Eject
PCMCIA Slots
BLACK BOX® CS Installation, Administration, and User’s Guide
47
Connecting AlterPath PM IPDUs
Figure 2-4: PCMCIA Eject Button in Web Manager
2.
Physically remove the card from the slot.
T To Configure a PCMCIA Card
See Chapter 8, “To Configure a PCMCIA Card”, and the sections related to
the type of card you need to configure.
Connecting AlterPath PM IPDUs
You can connect AlterPath Power Management (PM) intelligent power
distribution units (IPDUs) to the serial ports on the CS using an RJ-45 to RJ-
45 UTP cable. AlterPath PM includes two RS-232 outlets for serial
management and daisy-chaining. Any combination of Alter PM models up to
128 outlets can be daisy-chained into a single virtual power distribution unit.
The following figure shows an CS and two AlterPath PM8 IPDUs daisy-
chained. One PM is connected to a serial port on CS configured for power
management, and a second PM is daisy-chained from the first PM.
Installation and Configuration
48
Figure 2-5: AlterPath PMs Connected to the CS
The following table lists the related tasks on connecting IPDU units and
managing power.
T To Daisy-Chain AlterPath PMs to the CS
This procedure assumes that you have one AlterPath PM connected to a serial
port on the CS.
1.
Connect one end of a UTP cable with RJ-45 connectors to the “OUT” port
of the AlterPath PM that is connected to the serial port on CS.
2.
Connect the other end of the cable to the “IN” port of the next AlterPath
PM.
3.
Repeat Steps 1 and 2 until you have connected the desired number of
AlterPath PMs.
Table 2-4: Tasks Related to Connecting AlterPath PMs
Task
Where Documented
Configure serial ports for power
management protocol.
“To Configure a Serial Port for IPDU or
IPMI Power Management” on page 274
How the administrators perform IPDU power
management using the Web Manager
“IPDU Power Mgmt.” on page 120
How the regular users manager power outlets
using the Web Manager
“To Close an SSH Session” on page 56
Connect the AlterPath PM to the CS unit, and
daisy-chain multiple PM units.
“To Daisy-Chain AlterPath PMs to the CS”
on page 48
Configure users for IPDU power
management
“To Configure Users to Manage Power
Outlets on IPDUs” on page 128
Configure servers for IPMI power
management while connected.
“To Delete, Add, or Edit an IPMI Device to
Enable or Disable IPMI Power
Management” on page 142
Web Manager for Regular Users
This chapter describes the requirements and the procedures for “Regular
Users” to use the Web Manager. Regular users are those who have configured
accounts on the CS with limited access rights.
Regular users can perform the following tasks using the Web Manager.
•
Access computers and devices that are connected to the serial ports on the
CS.
•
Perform IPDU power management.
•
Change their current password.
This chapter contains the following sections.
Using the Web Manager
CS users perform most tasks through the Web Manager. The Web Manager
runs in a browser and provides a real-time view of all the equipment that is
connected to the CS.
Using the Web Manager
Page 49
Features of Regular User Forms
Page 51
Connect Form
Page 52
IPDU Power Management
Page 56
IPDU Multi-Outlet Control
Page 60
Security
Page 63
Web Manager for Regular Users
50
The CS administrator can use the Web Manager to configure users and ports.
An authorized user can access connected devices through the Web Manager to
troubleshoot, maintain, recycle power, and reboot connected devices.
T Logging in to the Web Manager
1.
Connect your web browser to CS by typing in the Console Access
Server’s IP address (e.g., https://10.10.10.10) provided to you by your
system administrator in your internet browser.
Note: Refer to Chapter 2, “ for the requirements to start with the Web Manager.
Press Enter.
The system brings up the CS Web Manager Login form.
2.
Type in your username and password as provided to you by your system
administrator.
Figure 3-1: Regular User > Web Manager Login form
BLACK BOX® CS Installation, Administration, and User’s Guide
51
Features of Regular User Forms
Features of Regular User Forms
The following figure shows features of the Web Manager when regular users
log in.
Figure 3-2: Regular User Form
The form in the middle changes according to which menu option is selected.
The following table illustrates the functions that are common to all the forms.
Table 3-1: Common Screen Information
Form Area
Purpose
Click this button to log out.
Form area
Menu
Logout button and CS information area
Web Manager for Regular Users
52
Connect
When you select the “Connect” option, the following form appears.
Figure 3-3: Regular User > Connect Form
You can use this form to connect to the CS console, or to one of the serial
ports as described in the following sections.
•
“Connect to CS” on page 53
•
“Connect to Serial Ports” on page 54
Permission to access a port or perform power management is granted by the
CS administrator when your user account is created. Contact your
administrator to gain authorization to access the serial port that the server or
devices is connected to.
Displays the hostname and IP address assigned during initial
configuration, and the model number of the CS.
Brings up the online help.
Table 3-1: Common Screen Information (Continued)
Form Area
Purpose
BLACK BOX® CS Installation, Administration, and User’s Guide
53
Connect
Connect to CS
When you click the “Connect to CS” radio button on the “Connect” form, a
Java applet viewer appears running an SSH session on the CS. The following
figure shows the Java applet when you connect to the CS. Note in the
“Connected to” message in the below figure at the top of the screen the IP
address of the CS followed by the session type, in this case “SSH”.
Figure 3-4: Java Applet
The following table describes the available buttons in the Java applet:
Table 3-2: Java Applet Buttons
Button
Purpose
To send a break to the terminal
Web Manager for Regular Users
54
Connect to Serial Ports
The list of serial ports includes the port names or administrator-defined aliases
only for ports you have permission to access. If the list is empty or does not
include a port you need to access, contact the CS system administrator.
Port Access Requirements
When you connect to a serial port to access a server or another device, access
rights to the specific serial port on CS is required. Your system administrator
can help with authorization to specific CS ports that your server or device is
connected to.
Note: If an authentication server is setup in your network, an authentication method
and the related parameters should be setup to allow access to the connected
devices. Consult your system administrator for configuring the authentication
method.
When you select a port from the Serial pull-down list and click the Connect
button, a Java applet viewer appears. A “Connected to” message in a gray area
at the top of the screen shows the IP address of the CS followed by the TCP
port number. See an example of the Java applet in Figure 3-4
Connection Protocols for Serial Ports
You can access a server or a device connected to a serial port by using the
connection protocol specified for the port. There are a number of connection
protocols for the serial ports, which your system administrator can setup
To disconnect from the Java applet
Select the left icon to reconnect to the server or device;
or select the right icon to end the session and
disconnect from the Java applet.
Table 3-2: (Continued)Java Applet Buttons
Button
Purpose
BLACK BOX® CS Installation, Administration, and User’s Guide
55
Connect
depending on your requirements. The following table shows the protocols
the CS administrator can choose for the serial ports.
TCP Port Numbers for Serial Ports
The TCP port numbers by default start at 7001 for serial port 1 and increments
up to the number of serial ports that your CS unit has. For example, an CS
with 8 serial ports have TCP ports 7001 through 7008. The CS administrator
may change the default port numbers, so if you use the defaults and they fail,
check with the administrator to find which port numbers to use.
T To Use Telnet to Connect to a Device Through a Serial Port
For this procedure, you need the hostname of the CS or its IP address and the
TCP port number for the serial port to which the device is connected.
•
To use Telnet in a shell, enter the following command:
T To Close a Telnet Session
Enter the Telnet hotkey defined for the client. The default is “Ctrl ]” and “q”
to quit.
Table 3-3: Serial Ports Connection Protocols
Connection Type
Protocol
Console Access Server (CAS)
Telnet, SSH, Telnet&SSH, Raw
Terminal Server (TS)
Telnet, SSHv1, SSHv2, Local Terminal,
Raw Socket
Dial-up
PPP-No Auth., PPP, SLIP, CSLIP
Other
Power Management, Bi-directional
Telnet
telnet hostname | IP_address TCP_port_number
Web Manager for Regular Users
56
T To Use SSH to Connect to a Device Through a Serial Port
For this procedure, you need the username configured to access the serial port,
the TCP port number, and the hostname of the CS or its IP address.
•
To use SSH in a shell, enter the following command:
T To Close an SSH Session
Enter the hotkey defined for the SSH client followed by a dot “.”. The default
is “~.”
Note: Make sure you enter the escape character followed by a “.” at the beginning of
a line to close the SSH session.
IPDU Power Mgmt.
IPDU or “Intelligent Power Distribution Units” management allows you to
manage the power outlets on the AlterPath PM products. When you select the
“IPDU Power Mgmt.” option, if you have permission to manage outlets on an
AlterPath PM, two tabs appear at the top of the form, as shown in the
following figure, “Outlets Manager” and “View IPDUs Info”.
Figure 3-5: Regular User > IPDU Power Mgmt. Forms
You can access the forms under IPDU Power Mgmt. menu to manage outlets,
or view IPDUs information:
ssh -l username:TCP_port_number CS_IP_address
BLACK BOX® CS Installation, Administration, and User’s Guide
57
IPDU Power Mgmt.
Outlets Manager
When you go to IPDU Power Mgmt.>Outlets Manager tab, the message
shown in the following figure appears if,
1- You do not have permission to manage power on any of the AlterPath PM
outlets or,
2- CS cannot detect an AlterPath PM that has been configured for power
management.
Contact the CS administrator for help, if you see this message.
Figure 3-6: Regular User > Outlets Manager (no permissions)
The following form appears if you have permission to manage power on one
or more outlets of the AlterPath PM.
Figure 3-7: Regular User > Outlets Manager (with permissions)
Web Manager for Regular Users
58
The form shows separate entries for each serial port configured for power
management, a name for the configured serial port if one is defined by the
administrator, and the number of IPDUs connected. The matrix displays a line
item for each outlet you are authorized to manage.
The authorized user can do the following for any listed outlet:
•
Edit the outlet name.
Enter a name to identify the server or device plugged into the outlet.
•
Edit the power up interval.
The power up interval is the time interval (in seconds) that the system
waits between turning on the currently-selected outlet and the next outlet.
The default is set at 30 seconds.
•
Cycle - Turn power briefly off and on again.
•
Turn the power On/Off to the outlet.
•
Lock or unlock the outlet to prevent accidental changes to the power state.
The following table describe the corresponding buttons to do the above
operations:
Table 3-4: Regular User > Outlet Management Buttons
Button
Purpose
Opens a dialog box to
Edit an Outlet name, and the
Power Up Interval.
Turn power briefly off and then on again.
Turn power On/Off.
Lock or unlock the outlet.
BLACK BOX® CS Installation, Administration, and User’s Guide
59
IPDU Power Mgmt.
View IPDUs Info
When you go to IPDU Power Mgmt.>View IPDUs Info, the form appears as
shown in the following figure.
Figure 3-8: Regular User > View IPDUs Info
The following information is displayed for each port that is configured for
power management.
Table 3-5: Regular User > Information on the View IPDUs Info Form
Description
Example
Name
Either a default name or administrator-configured
name.
PM
Number of
Units
The number of IPDUs connected to the port. The first
IPDU is referred to as the master. Any other IPDUs
daisy-chained off the first IPDU are referred to as
slaves.
1
Syslog
Whether syslogging has been configured for messages
from this IPDU.
ON
Buzzer
Whether a buzzer has been configured to sound when
a specified alarm threshold is exceeded.
ON
Number of
Outlets
Total number of outlets on all connected IPDUs.
8
Web Manager for Regular Users
60
IPDU Multi-Outlet Ctrl
Selecting IPDU Multi-Outlet Control form allows you to view and manage
the power on a group of outlets that provide power to a multi power supply
server or device connected to a serial port. Whether the outlets that the multi
Over Current
Protection
Whether over current protection is enabled (to prevent
outlets from being turned on if the current on the
IPDU exceeds the specified threshold).
OFF
Description
Example
Model
AlterPath PM model number
PM8 15A
Software Version
PM firmware version
1.5.0
Alarm Threshold
Number of amperes that triggers an alarm or syslog
message if it is reached
15.0A
Current
Current level on the IPDU
0.0A
Maximum
Detected
Maximum current detected
0.4A
Use this button to refresh the currently displayed
maximum detected temperature.
Temperature
Temperature on the AlterPath PM (Available only on
selected models that have temperature sensors)
Maximum
Detected
Maximum temperature detected (Available only on
selected models that have temperature sensors)
Use this button to refresh the currently displayed
maximum detected current.
Table 3-5: Regular User > Information on the View IPDUs Info Form
Description
Example
BLACK BOX® CS Installation, Administration, and User’s Guide
61
IPDU Multi-Outlet Ctrl
power supply device is connected to are on the same PM or not, the outlets
can be grouped together and managed simultaneously from this form.
When you select IPDU Multi-Outlet Ctrl form, the following figure appears
if,
1.
There is no multi-outlet device defined.
2.
Power Management is not enabled for the serial port the device is
connected to.
3.
CS cannot detect an AlterPath PM that has been configured for power
management.
Contact the CS administrator for help, if you see this message.
Figure 3-9: Regular User > IPDU Multi-Outlet (no permissions)
The following form appears if you have permission to view and control the
outlets that a multi power supply server or device is connected to.
Web Manager for Regular Users
62
Figure 3-10: Regular User > IPDU Multi-Outlet (with permissions)
Notice in the above figure that the first line of each group, the light bulb, the
lock icon, and the Cycle button operate over the entire group. The light bulb
and lock icons next to the individual outlets are used to display the status of
each outlet but cannot be used to control the individual outlets.
The following table describes the icons in the first line of each group.
Table 3-6: Regular User > IPDU Multi-Outlet Ctrl. Form Icons
Note: Only one outlet needs to be powered on or unlocked in order for the entire
group to be considered on or unlocked respectively. In this case, it takes two
clicks to turn the power off or to lock the entire group instead of the one click,
when all of the outlets are in the same state. The first click turns the other
outlets on or unlocks them so that all the outlets are in the same state; the
second click turns all of the outlets off or locks them.
The Cycle button operates only if all outlets of a group are turned on.
Note: The “PU (Power Up) interval" parameter configured for each outlet plays an
important role in the power up sequence of multi-outlet devices. The next
Button
Purpose
A grey light bulb icon indicates that the group is off.
A yellow light bulb indicates that the group is on.
Clicking the light bulb icon changes the power status of
all of the outlets in the group.
A grey and open lock icon indicates that the outlets are
unlocked and can be powered on or off.
A full-color and closed lock icon indicates that the
outlet is locked and cannot be turned on or off.
Clicking the lock icon changes the lock status of all of
the icons in the group.
Turn power briefly off and on again
BLACK BOX® CS Installation, Administration, and User’s Guide
63
Security
outlet in the group turns on only after the power up interval specified for the
current outlet has elapsed. This parameter can be configured through the
IPDU Power Mgmt. form. See “To Close an SSH Session” on page 56.
Security
When you select the “Security” menu option, the following form appears.
.
Table 3-7: Regular User > Password Management Form
T To Change Your Password
1.
Select the “Security” option from the menu panel.
The “Security” form appears.
2.
Enter your current password in the “Current Password” field.
3.
Enter the new password in the “New Password” and the “Repeat New
Password” fields.
4.
Click OK.
5.
Log out and log in using your new password to verify your password
change.
Web Manager for Administrators
Overview
This chapter is for system administrators who use the Web Manager to
configure the CS and its users. For information on how to configure CS using
vi or Command Line Interface (CLI), please consult the BLACK BOX® CS
Installation, Administration, and User’s Guide.
The CS Web Manager for administrators describes two modes of operation,
Wizard and Expert.
This chapter provides an overview of the Web Manager forms. The
subsequent chapters describe the menus, forms, and the configuration
procedures of the Web Manager in Wizard and Expert modes. If you are a
regular user see Chapter 3, “Web Manager for Regular Users”.
The sections listed in the following table provides background information
related to CS administrators’ use of the Web Manager, including explanations
of the types of information to be entered in each of the forms, and links to all
the procedures performed in each mode.
BLACK BOX® Web Manager
Page 66
Common Tasks for CS Administrators
Page 67
Common Features of Administrators’ forms
Page 68
Logging into the Web Manager
Page 70
Overview of Administrative Modes
Page 73
Web Manager for Administrators
66
BLACK BOX® Web Manager
CS administrators perform most tasks through the BLACK BOX® Web
Manager either locally or from a remote location. The Web Manager provides
a real-time view of the equipment that is connected to the CS.
The CS administrator can use the Web Manager to configure users and ports.
An authorized user can access connected devices through the Web Manager to
troubleshoot, maintain, recycle power, and reboot connected devices.
Access to the Web Manager can be through any of the following methods:
•
Through an Ethernet protocol network.
•
Through a dial-up protocol such as:
•
An optional modem connected to one of the serial ports.
•
An optional modem card inserted into one of the PCMCIA slots.
•
An optional CDMA wireless, GSM, or ISDN card.
Prerequisites for Using the Web Manager
The prerequisites described in this section must be completed before anyone
can access the Web Manager. If you have questions about any of the following
prerequisites, contact your system or network administrator.
•
Basic network parameters must be defined on the CS so the Web Manager
can be launched over the network.
•
The IP address of the CS must be known.
Note: If DHCP is enabled on CS, the IP address is not fixed. Anyone wanting to
access the CS must find out the currently-assigned IP address each time. If
DHCP is enabled and you do not know how to find out the current IP address
of the CS, contact your system administrator for help.
•
A user account must be defined on the Web Manager.
By default, the “root” has an account on the Web Manager. An
administrator with “root” access can add regular user accounts to access
connected devices.
BLACK BOX® CS Installation, Administration, and User’s Guide
67
Common Tasks for CS Administrators
Common Tasks for CS Administrators
The following table shows some of the common tasks that are performed by
an administrator and links to the process and procedure for performing the
task.
Table 4-1: Administrator > Common Administrative Tasks
Task
Where Documented
Set up users and groups to access
connected devices.
“Users and Groups” on page 208
Set up user authentication to access
serial ports.
“Access” on page 259
Configure serial ports for power
management.
“To Configure a Power Management Protocol
for an IPDU” on page 254
Assign users permissions to manage
outlets on connected AlterPath PMs.
“To Configure Users to Manage Power Outlets
on IPDUs” on page 128
Set up local or remote data buffering,
and specify alarms for one or more serial
ports.
“To Configure Data Buffering for Serial Ports”
on page 267
“To Choose a Method for Sending
Notifications for Serial Port Data Buffering
Events” on page 297
Set up logging of system messages to a
syslog server.
“To Specify Names, Alarms, Syslogging, and
Over Current Protection for IPDUs” on page
130
“To Configure Syslogging for Serial Ports and
Specify Message Filtering” on page 158“
Configure devices for IPMI power
management.
“IPMI Power Management” on page 139
Select an authentication method for
accessing connected devices.
“Authentication” on page 214
Configure packet filtering.
“Firewall Configuration” on page 186
Web Manager for Administrators
68
Common Features of Administrator Forms
The common features of all Web Manager forms for CS administrators are
described in the following sections.
• Buttons and CS Information
• Getting more information
Buttons and CS Information
The following figure shows the control buttons that display at the bottom of
the form when the logged in user is an administrator.
Figure 4-1: Administrator > Web Manager Buttons
The following table describes the uses for each control button.
Table 4-2: Administrator > Web Manager Buttons
Button Name
Use
back
Only appears in Wizard mode. Returns the
previous form.
try changes
Tests the changes entered on the current form
without saving them.
cancel changes
Cancels all unsaved changes.
apply changes
Applies all unsaved changes.
reload page
Reloads the page.
Help
Brings up the online help.
next
Only appears in Wizard mode. Goes to the
next form.
BLACK BOX® CS Installation, Administration, and User’s Guide
69
Common Features of Administrator Forms
The various Web Manager actions for trying, saving, and restoring
configuration changes are summarized in the following table.
The unsaved changes button appears on the
lower right hand corner of the Web Manager
and a graphical LED blinks red whenever the
current user has made any changes and has not
yet saved the changes.
The no unsaved changes button appears and a
graphical LED appears in green when no
changes have been made that need to be saved.
Table 4-3: Administrator > Options for Trying, Saving, and Restoring Configuration Changes
Task
Action
Result
try changes
Click the “try changes”
button”
Updates the appropriate configuration files.
Changes are preserved if you log in and log
out, and even if you restart the system.
Changes stay in effect unless the “cancel
changes” button is clicked. The changes can
be restored at any time until the “apply
changes” button is clicked.
cancel changes
Click the “cancel
changes” button
Restores the configuration files from the
backup that was created the last time
changes were applied.
apply changes
Click the “apply changes”
button
If “try changes” has not been previously
clicked, updates the appropriate
configuration files. Overwrites the backed
up copy of the configuration files.
Table 4-2: Administrator > Web Manager Buttons
Button Name
Use
Web Manager for Administrators
70
The following table illustrates the information that displays in the upper right
corner of all Web Manager forms.
Logging Into the Web Manager
The following procedure describes the login process to the Web Manager, and
what should be expected the first time you login to CS.
TTo Log Into the Web Manager
1 To bring up the Web Manager, enter the IP address of the CS in the address
field of your browser. For example, http://192.168.48.11
Note: Devices such as CS are usually assigned a static IP addresses. If DHCP is
enabled, you must find out the dynamically-assigned IP address each time you
need to run the Web Manager. Finding a dynamically-assigned IP address
requires making an inquiry to the DHCP server using the MAC address (a 12-
digit hexadecimal number, which is on a label on CS). Check with the system
administrator who configured the basic network parameters on the assigned IP
address. If there is no DHCP server, use the default static IP address
192.168.160.10 that is pre-configured in the CS.
a. If DHCP is disabled, use a static IP address assigned by the administrator.
b. If DHCP is enabled, enter the dynamically-assigned IP address.
The Login page appears.
Table 4-4: Administrator > Logout Button and Other Information in the Upper Right
Form Area
Purpose
Click this button to log out.
Displays the hostname, IP address assigned during initial
configuration, and the model number of the Advanced
Console Server.