Advanced Console Server

Installation, Administration, and User’s Guide Software Version 2.6.0 BLACK BOX® Corporation 1000 Park Drive Lawrence, PA 15055-1018 877-877-2269 http://www.blackbox.com Release Date: December 2005

© 2005 BLACK BOX® Corporation, all rights reserved

Information in this document is subject to change without notice. BLACK BOX® is the registered trademark of BLACK BOX® Corporation in the United States and other countries. All trademarks, trade names, logos and service marks referenced herein, even when not specifically marked as such, belong to their respective companies and are not to be considered unprotected by law.

Before You Begin ......................................................1

Audience .............................................................................................. 1 Document Organization ....................................................................... 1 Related Documents .............................................................................. 3 BLACK BOX® firmware Upgrades ................................................ 4 Chapter 1: Introduction .............................................7 Overview .............................................................................................. 8 Product Models and Configurations ..................................................... 8 Connectors on the BLACK BOX® CS .............................................. 10 Accessing CS and Connected Devices ............................................... 10 Web Manager ..................................................................................... 11 Prerequisites for Using the Web Manager ......................................... 11 Types of Users .................................................................................... 12 Security .............................................................................................. 12 Authentication .................................................................................... 13 VPN .................................................................................................... 15 Packet Filtering on CS ....................................................................... 15 Structure of IP Filtering .................................................................. 15 Chain ........................................................................................... 16 Rule ............................................................................................. 16 Add Rule and Edit Rule Options .................................................... 17 SNMP ................................................................................................. 22 Notifications, Alarms, and Data Buffering ........................................ 23

Syslog Servers ................................................................................ 23

Prerequisites for Logging to Syslog Servers ............................... 23 Administering Users of Connected Devices ...................................... 24 Planning Access to Connected Devices ......................................... 24 Configuring Access to Connected Devices .................................... 25 CS and Power Management ............................................................... 25 Configuring Power Management ................................................... 26 Configuring Ports for Power Management by Authorized Users 27 Configuring Ports for Power Management Using the CLI ......... 27 Options for Managing Power ......................................................... 28 Power Management Through the Web Manager ........................ 28 Power Management from the CS Command Line ...................... 28 Chapter 2: Installation and Configuration .............29 Shipping Box Contents ...................................................................... 30 Important Pre-installation Requirements ........................................... 34 Java Plug-In Requirement for Serial Port Access .......................... 35 Basic Installation Procedures ............................................................. 36 Mounting the CS ............................................................................. 37 Making an Ethernet Connection ..................................................... 37 Connecting Servers and Other Devices to CS ................................ 38 Making a Direct Connection to Configure the Network Parameters. ......................................................................................................... 39 Powering on the CS and the Connected Devices ........................... 39 Configuring the Network Parameters ............................................. 40 Performing Basic Network Configuration Using the wiz Command ...................................................................................................... 40 Selecting A Security Profile Using the Web Manager ............... 45 Adding Users and Configuring Ports Using the Web Manager ..... 46 Enabling Ports and Assigning Users. .......................................... 46 Other Methods of Accessing the Web Manager ................................ 47 Installing PCMCIA Cards .................................................................. 48 Connecting AlterPath PM IPDUs ...................................................... 49

BLACK BOX® CS Installation, Administration, and User’s Guide

v Chapter 3: Web Manager for Regular Users..........51 Using the Web Manager ..................................................................... 51 Features of Regular User Forms ........................................................ 53 Connect .............................................................................................. 54 Connect to CS ................................................................................. 55 Connect to Serial Ports ................................................................... 56 Port Access Requirements .......................................................... 56 Connection Protocols for Serial Ports ............................................ 56 TCP Port Numbers for Serial Ports ............................................. 57 IPDU Power Mgmt. ........................................................................... 58 Outlets Manager ............................................................................. 59 View IPDUs Info ............................................................................ 61 IPDU Multi-Outlet Ctrl ...................................................................... 62 Security .............................................................................................. 65 Chapter 4: Web Manager for Administrators ........67 BLACK BOX® Web Manager .......................................................... 68 Prerequisites for Using the Web Manager ...................................... 68 Common Tasks for CS Administrators .............................................. 69 Common Features of Administrator Forms ....................................... 70 Buttons and CS Information ........................................................... 70 Logging Into the Web Manager ......................................................... 72 Overview of Administrative Modes ................................................... 75 Wizard Mode .................................................................................. 76 Expert Mode ................................................................................... 76 Chapter 5: Configuring CS in Wizard Mode ..........79 Step 1: Security Profile ................................................................... 79 Pre-defined Security Profiles ...................................................... 79 Default Security Profile .............................................................. 80 Custom Security Profile .............................................................. 80 Serial Port Settings and Security Profiles ................................... 83 Step 2: Network Settings ................................................................ 87

Step 3: Port Profile ......................................................................... 90

Step 4: Access ................................................................................. 93 Step 5: Data Buffering .................................................................... 98 Step 6: System Log ....................................................................... 103 Chapter 6: Configuring the CS in Expert Mode...107 Overview of Menus and Forms ........................................................ 107 Mapping of the Expert Mode Menus and Forms ............................. 109 Description of Forms in Expert Mode ............................................. 110 Chapter 7: Applications Menu & Forms...............117 Applications ..................................................................................... 118 Connect ......................................................................................... 118 IPDU Power Mgmt. ...................................................................... 122 Outlets Manager ........................................................................ 123 View IPDUs Info ...................................................................... 126 Users Manager .......................................................................... 129 Configuration ............................................................................ 131 Software Upgrade [for the AlterPath PM] ................................ 133 IPDU Multi-Outlet Ctrl ................................................................ 135 Prerequisites for Multi-Outlet Control ...................................... 137 Power Management Icons ......................................................... 137 IPMI Power Management ............................................................. 141 Terminal Profile Menu ................................................................. 148 Chapter 8: Network Menu & Forms......................153 Network ............................................................................................ 154 Host Settings ................................................................................. 154 Syslog ........................................................................................... 159 PCMCIA Management ................................................................. 160 Configuring a Modem PCMCIA Card ...................................... 163 Configuring an ISDN PCMCIA Card ....................................... 166 Configuring a GSM PCMCIA Card ......................................... 168

BLACK BOX® CS Installation, Administration, and User’s Guide

vii Configuring an Ethernet PCMCIA Card ................................... 171 Configuring a PCMCIA Compact Flash Card or a PCMCIA Hard Disk Drive ................................................................................. 172 Configuring a Wireless LAN PCMCIA Card ........................... 174 Configuring a CDMA PCMCIA Card ...................................... 176 Ejecting a PCMCIA Card ......................................................... 178 VPN Connections ......................................................................... 178 SNMP ........................................................................................... 183 Firewall Configuration ................................................................. 188 Host Table .................................................................................... 203 Static Routes ................................................................................. 204 Chapter 9: Security Menu & Forms......................209 Users and Groups ......................................................................... 210 Adding a User ........................................................................... 211 Adding a Group ......................................................................... 212 Active Ports Sessions ................................................................... 214 Authentication .............................................................................. 216 Configuring Authentication for CS Logins ............................... 217 Configuring Authentication Servers for Logins to CS and Connected Devices ............................................................. 218 Group Authorization on TACACS+ ......................................... 222 Security Profiles ........................................................................... 228 Pre-defined Security Profiles ................................................... 229 Default Security Profile ............................................................ 229 Custom Security Profile ............................................................ 229 Serial Port Settings and Security Profiles ................................. 232 Security Certificates ..................................................................... 238 Certificate for HTTP Security ................................................... 238 User Configured Digital Certificate .......................................... 238 X.509 Certificate on SSH ......................................................... 238 Chapter 10: Ports Menu & Forms.........................239 Physical Ports ............................................................................... 241

General ...................................................................................... 243

Connection Profiles ................................................................... 244 Console Access Server (CAS) Profile Connection Protocols ... 245 Terminal Server (TS) Profile Connection Protocols ................. 245 Bidirectional Telnet Protocol .................................................... 247 Modem and Power Management Connection Protocols ........... 248 Access ....................................................................................... 261 Authentication Methods and Fallback Mechanism ................... 263 Data Buffering .......................................................................... 266 Multi User ................................................................................. 270 Power Management .................................................................. 273 Other ......................................................................................... 279 Virtual Ports .................................................................................. 283 Ports Status ................................................................................... 289 Ports Statistics .............................................................................. 290 Chapter 11: Administration Menu & Forms.........293 System Information ...................................................................... 294 Notifications ................................................................................. 297 Email Notifications Entry ......................................................... 299 Pager Notifications Entry .......................................................... 302 SNMP Trap Notifications Entry ............................................... 304 Serial Ports Alarm Notification ................................................ 306 Time/Date ..................................................................................... 307 Setting Time and Date with NTP .............................................. 308 Boot Configuration ....................................................................... 309 Backup Configuration .................................................................. 312 Upgrade Firmware ........................................................................ 315 Reboot ........................................................................................... 318 Online Help .................................................................................. 319 Appendix A: Technical Specifications.................321 Appendix B: Safety, Regulatory, and Compliance In-

BLACK BOX® CS Installation, Administration, and User’s Guide

ix formation ................................................................323 Safety Guidelines for Rack-Mounting the CS ................................. 323 Safety Precautions for Operating the Advanced Console Server ..... 324 Working inside the Advanced Console Server ................................ 326 Replacing the Battery ....................................................................... 326 FCC Warning Statement .................................................................. 327 Notice About FCC Compliance for all Advanced Console Server Models .............................................................................................. 327 Canadian DOC Notice ...................................................................... 327 Aviso de Precaución S-Mark Argentina .......................................... 328 Trabajar dentro del Advanced Console Server ................................ 329 Batería .............................................................................................. 329 Appendix C: Supported PCMCIA Cards ..............331 Glossary .................................................................335 Index .......................................................................353

Typographic Conventions................................................ 3

Table v-2: Other Terms and Conventions......................................... 4 Table 1-1: Model Numbers and Configuration Options ................... 8 Table 1-2: CS Supported Authentication Methods......................... 13 Table 1-3: Filter Options for Packet Filtering Rules....................... 17 Table 1-4: TCP Protocol Packet Filtering Options ......................... 18 Table 1-5: UDP Protocol Packet Filtering Options ........................ 19 Table 1-6: LOG Target Action Options .......................................... 21 Table 1-7: Tasks for Configuring Access to Connected Devices ... 25 Table 1-8: Tasks for Configuring Power Management................... 27 Table 1-9: Power Management Options in the Web Manager........ 28 Table 2-1: Shipping Box Contents for LS1004A - LS1048A ........ 30 Table 2-2: Shipping Box Contents for LS1001A............................ 33 Table 2-3: CS Basic Installation Tasks ........................................... 36 Table 2-4: Tasks Related to Connecting AlterPath PMs................. 50 Table 3-1: Common Screen Information ........................................ 53 Table 3-2: Java Applet Buttons...................................................... 55 Table 3-3: Serial Ports Connection Protocols................................. 57 Table 3-4: Regular User > Outlet Management Buttons ................ 60 Table 3-5: Regular User > Information on the View IPDUs Info Form ... .................................................................................... 61 Table 3-6: Regular User > IPDU Multi-Outlet Ctrl. Form Icons.... 64 Table 3-7: Regular User > Password Management Form............... 65 Table 4-1: Administrator > Common Administrative Tasks .......... 69

Administrator > Web Manager Buttons......................... 70

Table 4-3: Administrator > Options for Trying, Saving, and Restoring Configuration Changes.................................................. 71 Table 4-4: Administrator > Logout Button and Other Information in the Upper Right ............................................................. 72 Table 4-5: Administrator > CS Configuration and Expert Menus Chapters......................................................................... 77 Table 5-1: Wizard > Enabled services to access the CS under each security profile............................................................... 81 Table 5-2: Wizard > Enabled services to access the serial ports under each security profile. ..................................................... 81 Table 5-3: Wizard > Enabled protocols for each security profile shown with a check mark. ............................................. 82 Table 5-4: Wizard > Serial Port Profile Parameters and Usage...... 91 Table 5-5: Wizard > Add User Dialog: Field Names and Definitions .. ..................................................................................... 95 Table 5-6: Wizard > Data Buffering Field Names and Definitions . ... ... .................................................................................. 100 Table 5-7: Wizard > Differences Between Remote and Local Buffering...................................................................... 101 Table 5-8: CS Configuration and Expert Menus Chapters ........... 105 Table 6-1: Expert Mode Menu and Forms.................................... 109 Table 6-2: Expert > Applications................................................. 110 Table 6-3: Expert > Network .........................................................111 Table 6-4: Expert > Security......................................................... 112 Table 6-5: Expert > Ports.............................................................. 112 Table 6-6: Administration............................................................. 113 Table 7-1: Expert > Applications Menu ....................................... 117 Table 7-2: Expert > Outlets Manager Icons Description .............. 124 Table 7-3: Expert > View IPDUs General Information ................ 127 Table 7-4: Expert > View IPDUs Unit Information...................... 128 Table 7-5: Expert > IPDU Multi-Outlet Ctrl form icons .............. 138 Table 7-6: Expert > IPMI Information.......................................... 143 Table 7-7: Expert > IPMI Power Mgmt. Form Icons ................... 143 Table 8-1: Expert > Network Menu ............................................. 153

BLACK BOX® CS Installation, Administration, and User’s Guide

xiii Table 8-2: Expert > Host Settings Form Fields ............................ 155 Table 8-3: Expert > Form Fields for a Modem Card.................... 164 Table 8-4: Expert > Form Fields for an ISDN Card ..................... 167 Table 8-5: Expert > Form Fields For a GSM Card....................... 170 Table 8-6: Expert > Form Fields for an Ethernet Card................. 171 Table 8-7: Expert > Form Fields for a Compact Flash/Hard Disk 173 Table 8-8: Expert > Form Fields for a Wireless LAN Card. ........ 175 Table 8-9: Expert > Form Fields for a CDMA Card..................... 176 Table 8-10: Expert > Field and Menu Options for Configuring a VPN Connection................................................................... 181 Table 8-11: Expert > Fields and Menu Options for SNMP Configuration............................................................... 185 Table 8-12: Expert > Tasks for Configuring SNMP....................... 188 Table 8-13: Expert > TCP Options Fields ...................................... 195 Table 8-14: Expert > UDP Options Fields...................................... 196 Table 8-15: Expert > Firewall Configuration Input and Output Interface, and Fragments Fields Definitions. .............. 198 Table 8-16: Expert > Target LOG Options Selection Fields........... 199 Table 8-17: Expert > Reject Options Sections............................... 200 Table 8-18: Expert > Fields and Menus for Configuring Static Routes .... ................................................................................. 207 Table 9-1: Expert > Security Menu............................................... 209 Table 9-2: Expert > Add User Dialog Field Names and Definitions... ... .................................................................................. 211 Table 9-3: Expert > Active Ports Sessions Information. .............. 215 Table 9-4: Tasks for Setting up Authentication Servers. .............. 219 Table 9-5: Expert > Enabled services to access the CS under each security profile............................................................. 230 Table 9-6: Expert > Enabled services to access the serial ports under each security profile. ................................................... 230 Table 9-7: Expert > Enabled protocols for each security profile shown with a check mark. ........................................... 231 Table 9-8: Configuring CS in Expert Mode.................................. 237 Table 10-1: Expert > Ports Menu.................................................... 239

Table 10-2: Expert > Console Connection Protocols...................... 245

Table 10-3: Expert > Terminal Server (TS) Connected Protocols.. 246 Table 10-4: Expert > Protocols for Serial Ports Connected to Modems or IPDUs....................................................... 248 Table 10-5: Expert > Access Form Fields ...................................... 262 Table 10-6: Expert > Authentication Methods ............................... 264 Table 10-7: Expert > Procedures to Configure an Authentication Server........................................................................... 266 Table 10-8: Expert > Data Buffering Form Fields.......................... 267 Table 10-9: Expert > Multi User Form Fields ................................ 271 Table 10-10: Expert > Options on the “Allow Multiple Sessions” Menu ..... ................................................................................ 272 Table 10-11: Expert > Power Management Form Fields................. 274 Table 10-12: Expert > Ports > Physical Ports > Other Form Fields . 280 Table 10-13: Expert > New/Modify Port Dialog Box Fields............ 285 Table 10-14: Expert > Port Status Read-Only Form......................... 290 Table 10-15: Expert > Ports>Port Status Read-Only Form .............. 291 Table 11-1: Expert > Administration Menu.................................... 293 Table 11-2: System Information ..................................................... 296 Table 11-3: Expert > Notifications Form Fields............................. 298 Table 11-4: Expert > Email Notifications Dialog Box Fields ........ 300 Table 11-5: Expert > Pager Notifications Dialog Box.................... 303 Table 11-6: Expert > SNMP Trap Notifications Dialog Box ......... 305 Table 11-7: Expert > Boot Configuration Form Fields................... 310 Table 11-8: Expert > Backup Config Type FTP Form Fields and Buttons......................................................................... 313 Table 11-9: Expert > Backup Config Type Storage Device Form.. 314 Table 11-10: Expert > Upgrade Firmware Form Fields ................... 316 Table C-1: Supported PCMCIA Cards.......................................... 331

CS Front with PCMCIA Card Slots.............................. 8

Figure 1-2: CS Back with Connectors ............................................. 8 Figure 1-3: BLACK BOX® CS family of Advanced Console ......... Servers........................................................................... 9 Figure 1-4: CS Connectors............................................................. 10 Figure 1-5: IPDU Integration With CS.......................................... 26 Figure 2-1: CS Setup Example ...................................................... 30 Figure 2-2: Security Advisory Console Message .......................... 42 Figure 2-3: Front Panel PCMCIA Card Slots................................ 48 Figure 2-4: PCMCIA Eject Button in Web Manager..................... 49 Figure 2-5: AlterPath PMs Connected to the CS........................... 50 Figure 3-1: Regular User > Web Manager Login form ................. 52 Figure 3-2: Regular User Form...................................................... 53 Figure 3-3: Regular User > Connect Form .................................... 54 Figure 3-4: Java Applet.................................................................. 55 Figure 3-5: Regular User > IPDU Power Mgmt. Forms................ 58 Figure 3-6: Regular User > Outlets Manager (no permissions)..... 59 Figure 3-7: Regular User > Outlets Manager (with permissions).. 59 Figure 3-8: Regular User > View IPDUs Info ............................... 61 Figure 3-9: Regular User > IPDU Multi-Outlet (no permissions). 63 Figure 3-10: Regular User > IPDU Multi-Outlet (wit permissions)......

Administrator > Web Manager Buttons ...................... 70

Figure 4-2: Administrator > Web Manager Login Form ............... 73 Figure 4-3: Administrator > Multi Administrator Login Message 74 Figure 4-4: Administrator > Security Advisory Message.............. 75 Figure 4-5: Example of Web Manager Form in Wizard Mode...... 76 Figure 4-6: Example of Web Manager Form in Expert Mode....... 77 Figure 5-1: Administrator > Physical Ports Factory Settings ........ 83 Figure 5-2: Security and Serial Ports Configuration Alert ............ 83 Figure 5-3: Security Advisory Dialog Box.................................... 84 Figure 5-4: Wizard > Step 1: Security Profile Form...................... 85 Figure 5-5: Custom Security Profile Dialog Box .......................... 86 Figure 5-6: Wizard > Step 2: Network Settings - DHCP disabled. 88 Figure 5-7: Wizard > Step 2: Network Settings - DHCP enabled. 89 Figure 5-8: Wizard > Step 3: Port Profile ...................................... 90 Figure 5-9: Wizard > Step 4:Access .............................................. 94 Figure 5-10: Wizard > Step 4: Access Add User Dialog Box ......... 95 Figure 5-11: Wizard > Step 4: Change Password Dialog Box......... 96 Figure 5-12: Wizard > Step 5: Data Buffering [Inactive] ................ 98 Figure 5-13: Wizard > Step 5: Data Buffering [Local].................... 99 Figure 5-14: Wizard > Step 5: Data Buffering [Remote]............... 100 Figure 5-15: Wizard > Step 6: System Log ................................... 104 Figure 6-1: Expert Mode Screen Elements.................................. 108 Figure 7-1: Expert > Applications Menu Options ....................... 118 Figure 7-2: Expert > Applications > Connect Form .................... 119 Figure 7-3: Expert > SSH session Java Applet............................ 120 Figure 7-4: Expert > Serial Port Java Applet............................... 121 Figure 7-5: Expert > IPDU Power Mgmt. Tab Options............... 122 Figure 7-6: Expert > Applications > IPDU Power Mgmt. > Outlets

BLACK BOX® CS Installation, Administration, and User’s Guide

xvii Manager..................................................................... 124 Figure 7-7: Expert > Outlets Manager Icons ............................... 125 Figure 7-8: Expert > Edit Outlets Dialog Box............................. 125 Figure 7-9: IPDU Power Mgmt. > View IPDUs Info .................. 126 Figure 7-10: IPDU Power Mgmt> Users Manager....................... 129 Figure 7-11: Expert > IPDU Power Mgmt. > Users Manager > Add User ........................................................................... 129 Figure 7-12: Expert > Applications > IPDU Power Mgmt. > Configuration ............................................................ 132 Figure 7-13: Expert > Applications > IPDU Power Mgmt. > Software Upgrade..................................................................... 133 Figure 7-14: Expert > Applications > IPDU Multi-Outlet Ctrl .... 136 Figure 7-15: Expert > Applications > Multi-Outlet Ctrl [not configured]................................................................ 137 Figure 7-16: Expert > Applications > Multi-Outlet Control Icons138 Figure 7-17: Expert > Applications > IPMI Power Mgmt............. 141 Figure 7-18: Expert > IPMI Power Mgmt. “Add/Edit IPMI Device” Dialog Boxes............................................................. 142 Figure 7-19: Expert > IPMI Power Mgmt. Device Entry Example142 Figure 7-20: Expert > Serial Port > Power Management > Enable Power Management................................................... 146 Figure 7-21: Expert > Power Management Add Outlet Dialog Box .. ................................................................................... 146 Figure 7-22: Expert > Serial Port > Power Management > User Permissions ............................................................... 147 Figure 7-23: Expert > Serial Port > Power Management > Enable IPMI .......................................................................... 148 Figure 7-24: Expert > Applications > Terminal Profile Menu ...... 149 Figure 7-25: Expert >Terminal Profile Menu “Add Option” Dialog

Expert > Terminal Profile Menu Example................ 150

Figure 8-1: Expert > Network > Host Settings [DHCP Enabled] 154 Figure 8-2: Expert > Network > Host Settings [DHCP Disabled]155 Figure 8-3: Expert > Network > Syslog....................................... 159 Figure 8-4: Expert > Network > PCMCIA Management ............ 161 Figure 8-5: Expert > PCMCIA Modem Card Configuration Dialog Box............................................................................ 164 Figure 8-6: Expert > PCMCIA Modem Card Configuration Dialog Box -PPP................................................................... 165 Figure 8-7: Expert > Modem PCMCIA Card Configuration Dialog Box - Call Back......................................................... 165 Figure 8-8: Expert > ISDN PCMCIA Card Configuration Dialog Box............................................................................ 167 Figure 8-9: Expert > GSM PCMCIA Card Configuration Dialog Box............................................................................ 169 Figure 8-10: Expert > GSM PCMCIA Card Configuration Dialog Box - Call Back......................................................... 169 Figure 8-11: Expert > Ethernet PCMCIA Card Configuration Dialog Box............................................................................ 171 Figure 8-12: Expert > PCMCIA Compact Flash/Hard Disk Configuration Dialog Box....................................... 173 Figure 8-13: Expert > PCMCIA Wireless LAN Card Configuration Dialog Box ................................................................ 174 Figure 8-14: Expert > PCMCIA CDMA Card Configuration Dialog Box............................................................................ 176 Figure 8-15: Expert > Network > VPN Connections..................... 179 Figure 8-16: Expert > VPN “New/Modify Connection” Dialog Box.. ................................................................................... 180 Figure 8-17: Expert > Network > SNMP...................................... 184

BLACK BOX® CS Installation, Administration, and User’s Guide

xix Figure 8-18: Expert > “New/Mod SNMP v1 v2 Configuration” Dialog Box ................................................................ 186 Figure 8-19: Expert > “New/Mod SNMP v3 Configuration” Dialog Box............................................................................ 186 Figure 8-20: Expert > Network > Firewall Configuration............. 188 Figure 8-21: Expert > Firewall Configuration “Edit Chain” Dialog Box............................................................................ 189 Figure 8-22: Firewall Configuration “User-defined Chain” Message. ................................................................................... 190 Figure 8-23: Firewall Configuration “Delete Default Chain” Message ................................................................................... 190 Figure 8-24: Expert > Firewall Configuration “Add Chain” Dialog Box............................................................................ 191 Figure 8-25: Firewall Configuration “Edit Rules for chain_name” Form.......................................................................... 191 Figure 8-26: Firewall Configuration “Edit Rules for chain_name” Buttons ...................................................................... 192 Figure 8-27: Expert > Firewall Configuration “Add Rule” and “Edit Rule” Dialog Boxes .................................................. 192 Figure 8-28: Firewall Configuration “Add Rule” and “Edit Rule” .... Target Menu Options................................................. 193 Figure 8-29: Firewall Configuration “Add Rule” and “Edit Rule” Source and Destination IP and Mask Fields ............. 193 Figure 8-30: Firewall Configuration “Add Rule” and “Edit Rule” Protocol Menu Options ............................................. 194 Figure 8-31: Firewall Configuration “Add Rule” and “Edit Rule” Numeric Protocol Fields ........................................... 194 Figure 8-32: Firewall Configuration “Add Rule” and “Edit Rule” TCP Protocol Fields and Menu Options ................... 195

Firewall Configuration “Add Rule” and “Edit Rule”

UDP Protocol Fields ................................................. 196 Figure 8-34: Firewall Configuration “Add Rule” and “Edit Rule” ICMP Type Menu Options........................................ 197 Figure 8-35: Firewall Configuration Input and Output Interface Fields and Fragments Menu Options................................... 198 Figure 8-36: Firewall Configuration “Add Rule” and “Edit Rule” LOG Target Fields..................................................... 199 Figure 8-37: Firewall Configuration “Add Rule” and “Edit Rule” REJECT Target Menu Options ................................. 200 Figure 8-38: Expert > Network > Host Tables............................... 204 Figure 8-39: Expert > Network > Static Routes ............................ 205 Figure 8-40: Expert > Static Routes “Add” and “Edit” Dialog Boxes - Default Route ............................................................ 205 Figure 8-41: Expert > Static Routes “Add” and “Edit” Dialog Boxes - Network Route........................................................ 206 Figure 8-42: Expert > Static Routes “Add” and “Edit” Dialog Boxes - Host Route .............................................................. 207 Figure 9-1: Expert > Security > Users and Groups Form............ 210 Figure 9-2: Expert > Security > Users and Groups > “Add User” Dialog Box ................................................................ 211 Figure 9-3: Expert > Security > Users and Groups > “Add Group” Dialog Box ................................................................ 212 Figure 9-4: Expert > Security > Active Ports Sessions................ 215 Figure 9-5: Expert > Security > Authentication .......................... 217 Figure 9-6: Expert > Security > Authentication > AuthType Form... ................................................................................... 218 Figure 9-7: Expert > Security > Authentication > Radius........... 220 Figure 9-8: Expert > Security > Authentication > TACACS+ .... 221 Figure 9-9: Expert > Security > Authentication > LDAP............ 224

BLACK BOX® CS Installation, Administration, and User’s Guide

xxi Figure 9-10: Expert > Administration > Time/Date ..................... 226 Figure 9-11: Expert > Security > Authentication > Kerberos........ 227 Figure 9-12: Expert > Security > Authentication > NIS................ 228 Figure 9-13: Expert > Security > Security Profile........................ 228 Figure 9-14: Expert > Physical Ports Default Factory Settings.... 232 Figure 9-15: Security Profile and Serial Ports Configuration Alert232 Figure 9-16: Serial Ports Protocol Incompatibility Dialog Box .... 233 Figure 9-17: Security Advisory Dialog Box................................. 234 Figure 9-18: Wizard > Step 1: Security Profile Form.................... 235 Figure 9-19: Custom Security Profile Dialog Box ....................... 236 Figure 10-1: Expert > Ports........................................................... 240 Figure 10-2: Expert > Ports > Physical Ports................................ 241 Figure 10-3: Expert > Ports > Physical Ports > “Modify .... Ports ” Tab Options ............................................................... 242 Figure 10-4: Expert > Ports > Physical Ports > General Form..... 244 Figure 10-5: Expert > Ports > Physical Ports > Console Connection Active Tabs................................................................ 249 Figure 10-6: Expert > Ports > Physical Ports > Console Connection. ................................................................................... 249 Figure 10-7: Connection Protocols > Console............................... 250 Figure 10-8: Expert > Ports > Physical Ports > Bidirectional Telnet Active Tabs................................................................ 250 Figure 10-9: Expert > Ports > Physical Ports > Bidirectional Telnet Connection ................................................................ 251 Figure 10-10: Connection Protocols > Bidirectional Telnet........... 251 Figure 10-11: Expert > Ports > Physical Ports > Terminal Server Active Tabs ........................................................................... 252 Figure 10-12: Expert > Ports > Physical Ports > Terminal Server Connection ................................................................ 253

Figure 10-13: Connection Protocols > Terminal Server.................. 253

Figure 10-14: Expert > Ports > Physical Ports > Modem Connection Active Tabs................................................................ 254 Figure 10-15: Expert > Ports > Physical Ports > Modem Connection . ................................................................................... 255 Figure 10-16: Connection Protocols > Modem .............................. 255 Figure 10-17: Expert > Ports > Physical Ports > Power Management Active Tabs................................................................ 256 Figure 10-18: Expert > Ports > Physical Ports > Power Management Connection ................................................................ 257 Figure 10-19: Connection Protocols > Power Management............ 257 Figure 10-20: Access > Authentication Types................................. 258 Figure 10-21: Expert > Ports > Physical Ports > Serial Port Settings ... ................................................................................... 260 Figure 10-22: Expert > Ports > Physical Ports > Access Form ....... 261 Figure 10-23: Expert > Ports > Physical Ports > Data Buffering .... 266 Figure 10-24: Expert > Ports > Physical Ports > Data Buffering .... 267 Figure 10-25: Expert > Port > Physical Ports >Multi User ............. 271 Figure 10-26: Expert > Ports > Physical Ports > Power Management .. ................................................................................... 273 Figure 10-27: Expert > Ports > Physical Ports > Power Management . ................................................................................... 274 Figure 10-28: Expert > Ports > Physical Ports > Power Management > Add Outlets Dialog Box............................................ 276 Figure 10-29: Expert > Ports > Physical Ports > Power Management>Allow All Users ................................. 278 Figure 10-30: Expert > Ports > Physical Ports >Power Management >Allow Users/ Groups .............................................. 278 Figure 10-31: Expert > Ports > Physical Ports > Other Form.......... 279 Figure 10-32: Expert > Ports > Virtual Ports.................................. 284

BLACK BOX® CS Installation, Administration, and User’s Guide

xxiii Figure 10-33: Expert > Ports > Virtual Ports > New/Modify Port Dialog Box ................................................................ 285 Figure 10-34: Expert > Applications > Connect > Serial pull-down menu.......................................................................... 287 Figure 10-35: Expert > Ports > Virtual Ports > New/Modify Port Dialog Box ................................................................ 287 Figure 10-36: Expert > Ports > Virtual Ports > New/Modify > Port Names Dialog box..................................................... 289 Figure 10-37: Expert > Ports > Ports Status (Read-Only) ............... 290 Figure 10-38: Expert > Ports > Port Statistics (Read-Only)............ 291 Figure 11-1: Expert > Administration > System Information ....... 295 Figure 11-2: Expert > Administration > Notifications .................. 298 Figure 11-3: Expert > Administration > Notifications > Email > Add/ Edit Dialog box ......................................................... 300 Figure 11-4: Expert > Administration > Notifications > Pager > Add/ Edit Dialog box ......................................................... 302 Figure 11-5: Expert > Administration > Notifications > SNMP Trap > Add/Edit Dialog box ................................................. 305 Figure 11-6: Expert > Administration > Time/Date ...................... 307 Figure 11-7: Expert > Administration > Time/Date > NTP Enable308 Figure 11-8: Expert > Administration > Boot Configuration........ 309 Figure 11-9: Expert > Administration > Backup Config............... 312 Figure 11-10: Expert > Administration > Backup Config > Storage Device ....................................................................... 314 Figure 11-11: Expert > Administration > Upgrade Firmware......... 316 Figure 11-12: Expert > Administration > Reboot............................ 318 Figure 11-13: Expert > Administration > Online Help.................... 319

T To check Java Plug-in Support in the Browser..........................................35

T To Install JRE Version 1.4.2 or later and Register the Plug-in..................35 T To rack-mount CS, perform the following steps: ......................................37 T To Make an Ethernet Connection ..............................................................38 T To Connect Devices to Serial Ports ...........................................................38 T To Connect to the Console Port.................................................................39 T To Power on the CS...................................................................................39 T To Turn Power On Connected Devices .....................................................40 T To Log Into CS Through the Console........................................................40 T To Change the root password ....................................................................41 T To Use the wiz Command to Configure Network Parameters ..................42 T To Select a Security Profile .......................................................................45 T To Use a Dynamic IP Address to Access the Web Manager.....................47 T To Use the Default IP Address to Access the Web Manager ....................47 T To Install a PCMCIA Card ........................................................................48 T To Remove a PCMCIA Card.....................................................................48 T To Configure a PCMCIA Card..................................................................49 T To Daisy-Chain AlterPath PMs to the CS .................................................50 T Logging in to the Web Manager...............................................................52 T To Use Telnet to Connect to a Device Through a Serial Port ...................57 T To Close a Telnet Session..........................................................................57 T To Use SSH to Connect to a Device Through a Serial Port ......................58 T To Close an SSH Session...........................................................................58 T To Change Your Password ........................................................................65

T To Log Into the Web Manager...................................................................72

T To Select or Configure a Security Profile..................................................84 T To configure the Network Settings............................................................89 T To Set Parameters for All Serial Ports.......................................................92 T To Add a User............................................................................................96 T To Delete a User ........................................................................................97 T To Change a Password...............................................................................97 T To Configure Data Buffering...................................................................102 T To Add a Syslog Server...........................................................................104 T To Delete a Syslog Server........................................................................105 T To Connect to the CS...............................................................................121 T To Connect to a Device Through a Serial Port........................................122 T To View Status, Lock, Unlock, Rename, or Cycle Power Outlets..........125 T To View and Reset IPDU Information ....................................................128 T To Configure Users to Manage Power Outlets on IPDUs.......................130 T To Specify Names, Alarms, Syslogging, and Over Current Protection for IPDUs.......................................................................................................132 T To Download AlterPath PM Software From BLACK BOX® ................134 T To Upgrade Software on an AlterPath PM..............................................135 T To Power On or Power Off a Group of Outlets in the Same Power State139 T To Power On or Power Off a Group of Outlets in Different Power States ... ..................................................................................................................139 T To Lock or Unlock a Group of Outlets in the Same Power State............140 T To Lock or Unlock a Group of Outlets in Different Lock States ............140 T To Turn the Power of a Group of Outlets Off and On Again..................140 T To Delete, Add, or Edit an IPMI Device to Enable or Disable IPMI Power Management.............................................................................................144 T To Manage Power on an IPMI Device ....................................................145 T To Configure a Serial Port for IPDU or IPMI Power Management ........145 T To Configure a User for IPDU Power Management While Connected To a Serial Port.................................................................................................147 T To enable IPMI Power Management of an IPMI device connected to the currently-selected port .............................................................................148 T To Create a Menu for a Local Computer Terminal .................................150

BLACK BOX® CS Installation, Administration, and User’s Guide

xxvii T To Configure Host Settings [Expert].......................................................157 T To Configure Syslogging for Serial Ports and Specify Message Filtering .... ..................................................................................................................160 T To Configure a PCMCIA Card................................................................162 T To Configure a Modem PCMCIA Card...................................................166 T To Configure an ISDN PCMCIA Card...................................................167 T To Configure a GSM PCMCIA Card ......................................................170 T To Configure an Ethernet PCMCIA Card ...............................................172 T To Configure a Compact Flash PCMCIA Card or a PCMCIA Hard Disk Drive ........................................................................................................173 T To Configure a Wireless LAN PCMCIA Card........................................175 T To Configure a CDMA PCMCIA Card...................................................177 T To Eject a PCMCIA Card From the Card Slot ........................................178 T To Configure VPN...................................................................................182 T To Configure SNMP................................................................................186 T To Add a Chain........................................................................................201 T To Edit a Chain........................................................................................201 T To Add a Rule..........................................................................................202 T To Edit a Rule..........................................................................................203 T To Define the CS’s IP Address and Hostname........................................204 T To Configure Static Routes [Expert] .......................................................207 T To Add a User..........................................................................................212 T To Delete a User or Group.......................................................................213 T To Change a User’s Password .................................................................213 T To Add a Group .......................................................................................213 T To Modify a Group..................................................................................214 T To View, Kill, or Refresh Active User Sessions .....................................216 T To Configure the CS Login Authentication Method ...............................218 T To Configure a RADIUS Authentication Server.....................................220 T To Configure a TACACS+ Authentication Server..................................221 T To Configure an LDAP Authentication Server .......................................223 T To Configure a Kerberos Authentication Server .....................................225 T To Configure a NIS Authentication Server .............................................227 T To Select or Configure a Security Profile................................................233

T To Select One or More Serial Ports.........................................................242

T To Enable or Disable Serial Ports...........................................................243 T To Configure a Serial Port Connection Protocol for a Console Connection. ..................................................................................................................248 T To Configure a Serial Port Connection Protocol for a Bidirectional Telnet.. ..................................................................................................................250 T To Configure a Serial Port Connection Protocol for a Terminal Server..252 T To Configure a Serial Port Connection Protocol for an External Modem..... ..................................................................................................................254 T To Configure a Power Management Protocol for an IPDU.....................256 T To Associate an Alias to a Serial Port .....................................................259 T To Configure Serial Port Settings to Match the connected devices.........259 T To Configure User Access to Serial Ports ...............................................263 T To Configure a Serial Port Login Authentication Method ......................265 T To Configure Data Buffering for Serial Ports..........................................269 T To Configure Multiple Sessions and Port Sniffing for One or More Serial Ports .........................................................................................................272 T To Configure a Serial Port for IPDU or IPMI Power Management ........276 T To Configure a User for IPDU Power Management While Connected To a Serial Port.................................................................................................278 T To Configure TCP Port Number, STTY Options, Break Interval, and the Login Banner for a Serial Port Connected to a Console..........................281 T To Configure Terminal Server Connection Options................................282 T To Cluster CS Units or Modify Cluster Configuration............................287 T To Assign Names to Slave ports in the Cluster .......................................288 T To View System Information...................................................................297 T To Choose a Method for Sending Notifications for Serial Port Data Buffering Events..............................................................................299 T To Configure a Trigger for Email Notification for Serial Ports ..............301 T To Configure a Trigger for Pager Notification for Serial Ports...............303 T To Configure a Trigger for SNMP Trap Notification for Serial Ports ....306 T To Configure a Trigger for Serial Port Alarm Notification.....................306 T To Manually Set the Time and Date........................................................308 T To Configure Time and Date Using an NTP Server................................308 T To Configure CS Boot .............................................................................311

BLACK BOX® CS Installation, Administration, and User’s Guide

xxix T To Back Up or Restore the Configuration Files using an FTP Server.....314 T To Back Up or Restore the Configuration Files using a Storage Device 315 T To Upgrade the CS’s firmware................................................................317 T To Reboot the CS.....................................................................................318 T To Configure the Online Help Path .........................................................319

Before You Begin

This installation, administration, and user’s guide provides background information and procedures for installing, configuring, and administering the BLACK BOX® Advanced Console Server and for accessing connected servers and other connected devices. Audience This manual is intended for installers and system administrators of the CS and for users who may be authorized to connect to devices, to manage power through the CS, and to monitor the CS’s temperature. This document describes configuration, administration, and use of the CS only. It does not describe how to set up and administer other external services or servers that the CS may access for authentication, system logging, IPMI control, SNMP notifications, data logging, file sharing, or other purposes. This document assumes that users who are authorized to connect to servers and other devices through the CS already know how to use the connected devices. Document Organization The document contains the following chapters: 1: Introduction An overview of the features of the Advanced Console Server and necessary prerequisite information for understanding the rest of the information in this guide. 2: Installation and Configuration A list of tasks for installing and configuring the Advanced Console Server and connecting devices, with pointers to the needed background information and procedures.

Before You Begin

2 3: Web Manager for Regular Users Describes how authorized users use the Web Manager to access devices that are connected to ports on the CS. 4: Web Manager for Administrators Explains how the CS administrator uses the Web Manager to add and delete users, define port access, and perform other common administration tasks. 5: Configuring CS in Wizard Mode Describes the 6-step procedure to configure the Advanced Console Server in Wizard mode. Selecting a Security Profile, configure network settings, configure serial ports and access, and configure settings such as data buffering and system logging. 6: Configuring the CS in Expert Mode Provides an introduction to the Expert mode. Describes the forms in each section, and provides a mapping to each form with a link to the desired section. 7: Applications Menu & Forms Provides an overview of each form associated with the “Applications” menu, describes the functionality of the individual elements in each form, and provides step-by-step configuration procedures. 8: Network Menu & Forms Provides an overview of each form associated with the “Network” menu, describes the functionality of the individual elements in each form, and provides step-by-step configuration procedures. 9: Security Menu & Forms Provides an overview of each form associated with the “Security” menu, describes the functionality of the individual elements in each form, and provides step-by-step configuration procedures.

BLACK BOX® CS Installation, Administration, and User’s Guide

3 Related Documents 10: Ports Menu & Forms Provides an overview of each form associated with the “Ports” menu, describes the functionality of the individual elements in each form, and provides step- by-step configuration procedures. 11: Administration Menu & Forms Provides an overview of each form associated with the “Administration” menu, describes the functionality of the individual elements in each form, and provides step-by-step configuration procedures. Appendices Appendix A provides hardware specifications, and Appendix B details safety information. Index Provides a way to look up terms. In the online version of this manual, clicking the terms in the index brings you to where they are used in the manual. Related Documents The following document for the BLACK BOX® Advanced Console Server is shipped with the product. • Advanced Console Server Quick Start Guide (hard-copy) Typographic and Other Conventions The following table describes the typographic conventions used in BLACK BOX® manuals. Table v-1: Typographic Conventions Typeface Meaning Example Links Hypertext links or URLs Go to: http:// www.blackbox.com

Before You Begin

4 The following table describes other terms and conventions. BLACK BOX® firmware Upgrades BLACK BOX® offers periodic firmware upgrades for the Advanced Console Server. These upgrades are available free of charge to current BLACK BOX® customers. Visit ftp://ftp.blackbox.com/lan/Term-Servers/ to download the latest firmware. See “Upgrade Firmware” on page 313 for instructions on how to upgrade the firmware on your Advanced Console Server. Emphasis Titles, emphasized or new words or terms See the Advanced Console Server Quick Start. Filename or Command Names of commands, files, and directories; onscreen computer output. Edit the pslave.conf file. User type What you type in an example, compared to what the computer displays [root] ifconfig eth0 Table v-2: Other Terms and Conventions Term or Convention Meaning Examples Hot keys • When hot keys are shown with a plus (+) between two or three keys means that they must be pressed at the same time. • Pressing Ctrl+p brings up the IPMI power management. Navigation shortcuts Shortcuts use the “greater than” symbol (>) to indicate how to navigate to Web Manager forms. Go to Port > Physical Ports> Modify Selected Ports > Power Management Table v-1: Typographic Conventions Typeface Meaning Example

This chapter introduces the Advanced Console Server family of advanced

console servers, provides an overview of its features, and briefly describes the features for understanding the information and procedures in the rest of this manual. Overview Page 6 Advanced Console Server Models and Configurations Page 6 Connectors on the Advanced Console Server Page 8 Methods of Accessing CS and Connected Devices Page 8 Web Manager Page 9 Prerequisites for Using the Web Manager Page 9 Types of Users Page 10 Security Features Page 10 Authentication Page 11 VPN Page 13 Packet Filtering Page 13 SNMP Page 20 Notifications, Alarms, and Data Buffering Page 21

The Advanced Console Server is a 1U device that serves as a single access

point for using and administering servers and other devices. The following figure shows the front of the CS with its two PCMCIA card slots, and the back of a LS1032A with its Serial, Ethernet, and Console ports. Figure 1-1: LS1032A Front and back with PCMCIA Card Slots Product Models and Configurations The following table shows the available configurations. See Appendix A for hardware specifications. Administering Users of Connected Devices Page 22 Power Management Page 23 Table 1-1: Model Numbers and Configuration Options Model Number Serial Ports LS1001A 1 LS1004A 4

BLACK BOX® CS Installation, Administration, and User’s Guide

7 Product Models and Configurations The following figure illustrates the BLACK BOX® family of advanced console servers. Figure 1-2: BLACK BOX® CS family of Advanced Console Servers LS1008A 8 LS1016A 16 LS1032A 32 LS1048A 48 Table 1-1: Model Numbers and Configuration Options Model Number Serial Ports

Connectors on the BLACK BOX® CS

The following figure depicts the connectors on the back of a LS1008A. Figure 1-3: LS1008A Connectors The number of serial ports and power supplies depends on the model, see table 1-1 for model numbers and configurations options. Accessing CS and Connected Devices You can access CS and the connected servers or devices locally or remotely using any of the following methods. • Using the Web Manager through LAN/WAN IP networks. • Using a modem, ISDN, GSM, or CDMA optional PCMCIA card. • Using the Web Manager you can login and launch a console session such as Telnet or SSH to connect to the console of devices that are connected to the CS’s serial ports. • By connecting a computer running a terminal emulation program, an CS administrator can log into the CS box and enter commands in the CS shell or use the Command Line Interface (CLI) tool. Note: Only one user logged in as “root” or “admin” can have an active CLI or Web Manager session. A second user who connects through the CLI or the Web Manager as the “root” or “admin” has a choice to abort the session or close the other user’s session. Serial Ports Ethernet Port Console Port Power Supply

BLACK BOX® CS Installation, Administration, and User’s Guide

9 Web Manager Note: If there are cron jobs running through automated scripts, a “root” or “admin” user login can cause the automated cron jobs to fail. Make sure that the users with administrative privileges are aware of this. Web Manager CS administrators perform most tasks through the Web Manager either locally or from a remote location. The Web Manager runs in a browser and provides a real-time view of all the equipment that is connected to the CS. The CS administrator can use the Web Manager to configure users and ports. An authorized user can access connected devices through the Web Manager to troubleshoot, maintain, recycle power, and reboot connected devices. Access to the Web Manager is through one of the following ways: • Through the IP Network. • Through a dial-in or callback connection with one of the following: • An optional external modem connected to one of the serial ports. • A modem on an optional PCMCIA modem card. • An optional CDMA, GSM, or ISDN card. Prerequisites for Using the Web Manager The prerequisites described in this section must be complete before anyone can access the Web Manager. If you have questions about any of the following prerequisites, contact your system or network administrator. • Basic network parameters must be defined on the CS so the Web Manager can be launched over the network. See “Performing Basic Network Configuration Using the wiz Command” on page 38. • The IP address of the CS must be known. When DHCP is enabled, a leased IP address is assigned to CS. The leased IP address may change every time CS reboots. Therefore, an additional step needs to be taken to find out the dynamically-assigned IP address before the Web Manager can be accessed through the browser. Following are three ways to find out the dynamically-assigned IP address:

Make an inquiry to the DHCP server on the subnet that the CS resides,

using the MAC address (The MAC address is labeled at the bottom of the CS). • Connect to CS remotely using Telnet or SSH and use the ifconfig command. • Connect directly to the CS and use the ifconfig command through a terminal emulator application. • A user account must be defined on the Web Manager. By default, the “admin” has an account on the Web Manager. An administrator can add regular user accounts to grant access to the connected servers or devices using the Web Manager. Types of Users CS supports the following user account types: • The “root” user who can manage the CS and its connected devices. The “root” user performs the initial network configuration. Access privileges are full read/write and management. Note: It is strongly recommended to change the default password “bb” before setting up the CS for secure access to the connected servers or devices. • Users who can be part of an “Admin” group with administrative privileges. This may be a regular user who can perform the same tasks as an administrator. • Regular users who can access the connected devices through the serial ports they are authorized for. Regular users have limited access to the Web Manager features. Security The Advanced Console Server includes a set of security profiles that consists of predefined parameters to control access to CS and its serial ports. This feature provides more control over the services that are active at any one time. As an additional security measure, all serial ports are disabled by default, which allows the administrator to enable and assign individual ports to users. See “Security Profiles” on page 226 for detailed information and procedures.

BLACK BOX® CS Installation, Administration, and User’s Guide

11 Authentication Authentication CS supports a number of authentication methods that can help the administrator with the user management. Authentication can be performed locally or with a remote server, such as RADIUS, TACACS+, LDAP, or Kerberos. An authentication security fallback mechanism is also employed, should the negotiation process with the authentication server fails. In such situations, the CS follows an alternate defined rule when authentication server is down or does not authenticate the user. The following table lists the supported authentication methods. Table 1-2: CS Supported Authentication Methods Authentication Type Definition None No authentication. Kerberos Authentication is performed using a Kerberos server. Kerberos/Local Kerberos authentication is tried first, switching to Local if unsuccessful. KerberosDownLocal Local authentication is performed only when the Kerberos server is down. LDAP Authentication is performed against an LDAP database using an LDAP server. LDAP/Local LDAP authentication is tried first, switching to Local if unsuccessful. LDAPDownLocal Local authentication is performed only when the LDAP server is down. Local Authentication is performed locally. For example using the /etc/passwd file. Local/Radius Authentication is performed locally first, switching to Radius if unsuccessful.

Authentication is performed locally first,

switching to TACACS+ if unsuccessful. Local/NIS Authentication is performed locally first, switching to NIS if unsuccessful. NIS NIS authentication is performed. NIS/Local NIS authentication is tried first, switching to Local if unsuccessful. NISDownLocal Local authentication is performed only when the NIS server is down. Radius Authentication is performed using a Radius authentication server. Radius/Local Radius authentication is tried first, switching to Local if unsuccessful. RadiusDownLocal Local authentication is performed only when the Radius server is down. TACACS+ Authentication is performed using a TACACS+ authentication server. TACACS+/Local TACACS+ authentication is tried first, switching to Local if unsuccessful. TACACS+DownLocal Local authentication is tried only when the TACACS+ server is down. Authentication Type Definition

BLACK BOX® CS Installation, Administration, and User’s Guide

13 VPN VPN The CS administrator can set up VPN connections to establish an encrypted communications between the CS and a host on a remote network. The encryption creates a security tunnel for a dedicated communications. You can use the VPN features on CS to create the following types of connections: • A secure tunnel between CS and a gateway at a remote location so every machine on the subnet at the remote location has a secure connection with CS. • Create a secure tunnel between CS and a single remote host To set up a security gateway, you can install IPSec on any machine that does networking over IP, including routers, firewall machines, application servers, and end-user machines. The ESP and AH authentication protocols are supported. RSA Public Keys and Shared Secret are also supported. For detailed information and procedures to configure a VPN connection, see “VPN Connections” on page 176. Packet Filtering on CS The CS administrator can configure the box to filter packets like a firewall. IP filtering is controlled by chains and rules. Structure of IP Filtering The Firewall Configuration form in the Web Manager is structured on two levels: • The view table of the “Firewall Configuration” form which contains a list of chains. • The chains which contain the rules that control filtering.

A chain is a named profile that includes one or more rules that define the

following: • A set of characteristics to look for in a packet • What to do with any packet that has all the defined characteristics The CS filter table contains a number of built-in chains. The CS administrator can define additional chains and can edit the built-in chains. The built-in chains are referenced according to the type of packet they handle as shown in the following list: • INPUT - For incoming packets. • FORWARD - For packets being routed through CS. • OUTPUT - For outgoing packets. As defined in the rules for the default chains, all input and output packets, and packets being forwarded are accepted. Rule Each chain can have one or more rules that define the following: • The packet characteristics being filtered. The packet is checked for characteristics defined in the rule. For example, a specific IP header, input and output interfaces, TCP flags and protocol. • What to do when the packet matches the rule. The packet can be handled according to a specified target policy such as accepted, dropped, returned, logged, or rejected. When a packet is filtered, its characteristics are compared against the rules one-by-one. All defined characteristics must match. If no rules are found then the default action for that chain is applied. Administrators can do the following to specify packet filtering: • Add a new chain and specify rules for that chain • Add new rules to existing chains • Edit a built-in chain or delete the built-in chain rules

BLACK BOX® CS Installation, Administration, and User’s Guide

15 Packet Filtering on CS Add Rule and Edit Rule Options When you add or edit a rule you can define any of the options described in the following table. You can flag any of the above elements with inverted so that the target action is performed on packets that do not match any of the criteria specified in that line. For example, if you select DROP as the target action, specify “Inverted” for a source IP address, and do not specify any other criteria in the rule, any Table 1-3: Filter Options for Packet Filtering Rules Filter Options Description Source IP and Mask Destination IP and Mask If you specify a source IP, incoming packets are filtered for the specified IP address. If you specify a destination IP, outgoing packets are filtered for the specified IP address. If you fill in a source or destination mask, incoming or outgoing packets are filtered for IP addresses from the subnetwork in the specified netmask. Protocol You can select a protocol for filtering from one of the following options: • ALL • Numeric Protocol Options • TCP Protocol Options • UDP Protocol Options • ICMP Protocol Options Input Interface The input interface (ethN) used by the incoming packet. Output Interface The output interface (ethN) used by the outgoing packet. Fragments The types of packets to be filtered: • All packets • 2nd, 3rd... fragmented packets • Non-fragmented and 1st fragmented packets

packets arriving from any other source IP address than the one specified are

dropped. Numeric Protocol Options If you select Numeric as the protocol when specifying a rule, you need to specify the desired number. TCP Protocol Options If you select TCP as the protocol when specifying a rule, you can define the following options. Table 1-4: TCP Protocol Packet Filtering Options Field/Menu Option Definition Source Port - OR - Destination Port You can specify a source or destination port number for filtering in the “Source Port” or “Destination Port” field. You can also specify a range so that TCP packets are filtered for any port number within the range. TCP Flags Specifying any of the flags: “SYN” (synchronize), “ACK” (acknowledge), “FIN” (finish), “RST” (reset), “URG” (urgent), “PSH” (push), and one of the “Any,” “Set,” or “Unset” conditions, filters TCP packets for the specified flag and the selected condition.

BLACK BOX® CS Installation, Administration, and User’s Guide

17 Packet Filtering on CS UDP Protocol Options When you select UDP as a protocol when specifying a rule, you can select the UDP options defined in the following table. ICMP Protocol Options When you select ICMP as a protocol when specifying a rule, you can select the following ICMP options. • all • echo-reply • destination-unreachable • network-unreachable • host-unreachable • protocol-unreachable • port-unreachable • fragmentation-needed • source-route-failed • network-unknown • host-unknown • network-prohibited • host-prohibited • TOS-network-unreachable • TOS-host-unreachable • communication-prohibited • host-precedence violation Table 1-5: UDP Protocol Packet Filtering Options Field Definition Source Port - OR - Destination Port Specify a source or destination port number for filtering in the “Source Port” or “Destination Port” field. You can specify a source or destination port number for filtering in the “Source Port” field. You can also specify a second number so that UDP packets are filtered for any port number within the range.

The “Target” is the action to be performed on an IP packet that matches all the

criteria specified in a rule. The target actions are: • ACCEPT • DROP • RETURN • LOG • REJECT

BLACK BOX® CS Installation, Administration, and User’s Guide

19 Packet Filtering on CS If the “LOG” and “REJECT” targets are selected, additional options are available. The following table describes the options for the “LOG” Target. Table 1-6: LOG Target Action Options The following list shows the options for the REJECT Target: • icmp-net-unreachable • icmp-host-unreachable • icmp-port-unreachable • icmp-proto-unreachable • icmp-net-prohibited • icmp-host-prohibited • echo-reply • tcp-reset Options Definition Log Level emerg alert crit err warning notice info debug Log Prefix The prefix to use in the log entry. TCP Sequence Includes the TCP sequence in the log. TCP Options Includes TCP options in the log. IP Options Includes IP options in the log.

Firewall Configuration Procedures

The following table has links to the procedures for defining packet filtering using the Web Manager. SNMP The CS administrator can activate Simple Network Management Protocol (SNMP) agent that resides on the CS so that the SNMP agent sends notifications about significant events or traps to an SNMP management application. The CS SNMP agent supports SNMP v1/v2 and v3. The following table shows the tasks related to administering SNMP on the CS and provides links to where they are documented. To Add a Chain Page 199 To Edit a Chain Page 199 To Add a Rule Page 200 To Edit a Rule Page 201 To Configure SNMP See “To Configure SNMP” on page 184. To configure one or more serial ports to send SNMP traps. See “SNMP Trap Notifications Entry” on page 302

BLACK BOX® CS Installation, Administration, and User’s Guide

21 Notifications, Alarms, and Data Buffering Notifications, Alarms, and Data Buffering The CS administrator can setup logging, notifications, and alarms to alert administrators about problems. System generated messages on CS and the connected servers or devices can be sent to syslog servers for handling. The administrator can also configure data buffering to store data from communication on serial ports for monitoring. Data from communication with serial-connected consoles can be stored: • Locally in the CS’s flash memory, or • Remotely either on an NFS server or a syslog server. Syslog Servers Messages about the CS and connected servers or devices can be sent to a central logging servers, called syslog servers. Console data from devices connected to serial ports can be stored in data buffer files on syslog servers. By default logging and data buffering are not done. Prerequisites for Logging to Syslog Servers Before configuring syslogging, the CS administrator must ensure that syslog server is pre-configured with a public IP address, and it is accessible from CS. The CS administrator must be able to obtain the following information from the syslog server’s administrator. • The IP address of the syslog server • The facility number for messages coming from the CS. Facility numbers are used on the syslog server for handling messages generated by multiple devices. Facility Numbers for Syslog Messages Each syslog server has seven local facility numbers available for its administrator to assign to different devices or groups of devices at different locations. The available facility numbers are Local0 through Local7.

An Example of Using Facility Numbers

The syslog system administrator sets up a server called “syslogger” to handle log messages from two CS boxes. One CS is located in São Paulo, Brazil, and the other in Fremont, California. The syslog server’s administrator wants to aggregate messages from the São Paulo CS into the local1 facility, and to aggregate messages from Fremont CS into the local2 facility. On “syslogger” the system administrator has configured the system logging utility to write messages from the local1 facility to the /var/log/ saopaulo-config file and the messages from the local2 facility to the / var/log/fremont-config file. If you were in Fremont and identifying the syslog server using the Web Manager, according to this example, you would select the facility number Local2 from the “Facility Number” pull-down menu on the Syslog form. Administering Users of Connected Devices This sections provides a list of task that an CS administrator can perform to enable access to connected devices. Planning Access to Connected Devices The CS administrator needs to perform specific tasks to setup and configure user access to the connected servers, IPDUs, or other devices. An advanced planning can minimize issues that may arise during software configuration. Some of the planning steps includes the following: • Create a list of servers or devices to connect to the serial ports. • Create a list of users with the type of access each user requires. • Create a matrix of users and required access to each connected server or device. • Create meaningful aliases to assign to port numbers. • List all devices that need to be connected to IPDUs and the users who need to access them.

BLACK BOX® CS Installation, Administration, and User’s Guide

23 CS and Power Management Configuring Access to Connected Devices During hardware installation of CS, the installer connects the servers, devices, and any IPDUs to the serial ports. During software configuration, the CS administrator performs the common tasks listed in the following table. CS and Power Management CS enables users who have power management permissions to power off, power on, and reboot devices. The CS offers the following power management options: • Remote power management of servers that have IPMI controllers. The CS's implementation of the Intelligent Platform Management Interface (IPMI) protocol lets authorized users manage power for servers that have embedded IPMI controllers. IPMI servers do not need to be connected to the CS because their IPMI controllers respond to out-of-band IPMI Table 1-7: Tasks for Configuring Access to Connected Devices Task Where documented Configure a serial port connection protocol for a console connection Page 246 Configure user access to serial ports. Page 261 Configure a serial port for IPDU or IPMI power management Page 274 Configure a user for IPDU power management Page 276

commands. Authorized users can also perform IPMI power management

of serially-connected devices. The CS uses IPMI V1.5. • Remote power management of devices that are plugged into an IPDU that is connected to CS • The intelligent power distribution unit (IPDU) can be an AlterPath PM connected to any serial port. Up to 128 IPDU outlets can be daisy- chained. • The diagram below shows a typical setup of the CS and an AlterPath PM unit. Figure 1-4: IPDU Integration With CS Configuring Power Management Administrators commonly perform power management through the Web Manager, to assign power management permissions to users, configure IPMI devices, and configure ports for power management.

BLACK BOX® CS Installation, Administration, and User’s Guide

25 CS and Power Management The following table list the tasks for power management and where they are described. Configuring Ports for Power Management by Authorized Users Administrators of connected devices who have power management permissions can do power management while connected by using a “hot key” that brings up a power management screen. For IPMI power management the default hot key is Ctrl+p. For IPDU power management the default hot key is Ctrl+Shift+I. Configuring Ports for Power Management Using the CLI CS administrators can use the CLI command with the config ipmi options to manage power on IPMI devices while logged into the CS with administrative rights. The ipmitool command is documented in the BLACK BOX® Advanced Console Server Command Reference Guide. Table 1-8: Tasks for Configuring Power Management Task Where Documented Configure users to manage power on IPDUs “To Configure a User for IPDU Power Management While Connected To a Serial Port” on page 276 Identify servers for IPMI power management “To Delete, Add, or Edit an IPMI Device to Enable or Disable IPMI Power Management” on page 142 Configure ports for power management by authorized users “To Configure a Serial Port for IPDU or IPMI Power Management” on page 274.

Options for Managing Power

The sections listed below describe the different ways that the authorized users can perform power management through CS. • From forms in the Web Manager • From a power management screen while logged into a device • From the command line while logged into CS An authorized user with administrative privileges can perform IPDU and IPMI power management. A Regular User with permissions to the connected devices can perform IPDU power management. Power Management Through the Web Manager Users with power management permissions can perform power management through the Web Manager. The Web Manager menu includes the two power management options listed in the following table, with links to where each is documented. Power Management from the CS Command Line CS administrators can use the ipmitool command to manage power on IPMI devices while logged into the CS with administrative rights. The ipmitool command is documented in the BLACK BOX® Advanced Console Server Command Reference Guide. Table 1-9: Power Management Options in the Web Manager Form Name Where Documented IPDU Power Mgmt • “IPDU Power Mgmt.” on page 120 • “To View Status, Lock, Unlock, Rename, or Cycle Power Outlets” on page 123 IPMI Power Mgmt • “IPMI Power Management” on page 139 • “To Delete, Add, or Edit an IPMI Device to Enable or Disable IPMI Power Management” on page 142 • “To Manage Power on an IPMI Device” on page 143

Installation and Configuration

This chapter covers the topics listed in the following table. The following figure illustrates an example of an CS configured with connected devices. Shipping Box Contents Page 28 Important Pre-Installation Requirements Page 32 Basic Installation Procedures Page 34 Other Methods of Accessing the Web Manager Page 45 Installing PCMCIA Cards Page 46 Connecting AlterPath PM IPDUs Page 47

Installation and Configuration

28 Figure 2-1: CS Setup Example Shipping Box Contents The shipping box contains the CS along with the items shown in Table 2-1 and Table 2-2 for CS4 through CS48, and CS1 respectively. The entry for each part provides an illustration, its part number, description, and purpose. You can use checkboxes to check off each item, and you can use the part numbers from this table to reorder any of the parts. The list is numbered for internal cross-referencing among descriptions within this table. Table 2-1: Shipping Box Contents for LS1004A - LS1048A R Item Description Purpose 1. Documentation CD PDF copies of this guide.

BLACK BOX® CS Installation, Administration, and User’s Guide

29 Shipping Box Contents 3. Power cable. To connect the CS to a power source. 4. RJ45 to DB25F crossover adapter To connect the console port to a computer that has a DB-25 male connector. 5. RJ45 to DB25M crossover adapter To connect the console port to a computer that has a DB-25 female connector. 6. RJ45 to DB9F crossover adapter To connect the console port to a computer that has a DB-9 connector. 7. Sun/Netra crossover adapter To connect the console port to a Sun Netra server, or other devices with the same pinout configuration. 8. RJ45 to RJ45 7ft. CAT5 cable Use for the following: • To connect a device or an IPDU to a serial port. • To connect an Ethernet port to the LAN. • To connect a terminal to a console port. R Item Description Purpose

Installation and Configuration

30 9. RJ45 to DB25M straight-thru cable Use for modems and other DCE devices. 10. DB25F Loopback Use to test and diagnose serial ports. 11. 2 - Mounting brackets with 10 - screws (2 spares) Use to mount the CS to a rack or cabinet. R Item Description Purpose

BLACK BOX® CS Installation, Administration, and User’s Guide

31 Shipping Box Contents Table 2-2: Shipping Box Contents for LS1001A R Item Description Purpose 1. Documentation CD PDF copies of this guide. 3. RJ45 to DB9F crossover adapter To connect the console port to a computer that has a DB-9 connector. 4. DB25F Loopback Use to test and diagnose serial ports. 5. 3.5mm Block Plug Use to establish RS-485 connection. 6. DB9F to DB25M adapter Use to convert serial port connectors. 7. Bumpon Protect Pads Adhesive pads to protect and stabilize CS1.

Installation and Configuration

32 Important Pre-installation Requirements Before installing and configuring CS, ensure that you have the following: • Root Access on your local UNIX machine in order to use the serial ports. • An appropriate Terminal application for your operating system. • IP address, DNS, Network Mask, and Gateway addresses of your server or terminal, the CS, and the machine that CS is connected to. • A web browser that supports the CS Web Manager, such as Netscape, Internet Explorer 6.0, Firefox, or Mozilla. • Java 2 Runtime Environment (JRE) version 1.4.2 or later. J2RE can be downloaded from http://java.com. 8. RJ45 to RJ45 7ft. CAT5 cable Use for the following: • To connect a device or an IPDU to a serial port. • To connect an Ethernet port to the LAN. • To connect a terminal to a console port. 9. DB9F to DB25F crossover cable To connect the RS-232 serial port to a computer that has a DB-25 male connector. 10. Power Supply +5V/2.5A Power supply. 11. Power Cable 6ft. 2-Pin To connect the CS to a power source.

BLACK BOX® CS Installation, Administration, and User’s Guide

33 Important Pre-installation Requirements Java Plug-In Requirement for Serial Port Access The JRE version 1.4.2 or later must be installed for a user to be able to access a serial port using the Java applet viewing window. After you download and install J2RE version 1.4.2 or later, check your browser configuration to see if the Java plug-in is configured with your browser. T To check Java Plug-in Support in the Browser 1. To check Internet Explorer on Windows, do the following steps. a. Go to Tools > Internet Options > Advanced b. Scroll down and look for a section on Java. c. There should be a check box that says “Use Java 2 v1.4.2...." As shown in the following figure. d. If an option similar to the above figure does not appear, it means that JRE is not installed on your system. Or, if the option appears, but the checkbox is not enabled, this means your browser is not activated to use the Java plug-in that came with JRE. 2. To check Netscape or Mozilla on Windows, do the following steps. a. Go to Edit > Preferences >Advanced. b. Check the “Enable Java” checkbox. c. To see what version of the Java plug-in is registered, do the following steps. i. Go to Help > About Plug-ins. ii. Scroll to the Java Plug-in section. iii. Check whether the registered Java plug-in is the same as the version you installed. T To Install JRE Version 1.4.2 or later and Register the Plug-in 1. Make sure that JRE 1.4.2 or later is installed on the computer.

Installation and Configuration

34 If needed, download the JRE from http://java.com. The web site automatically checks your configuration and installs the latest version of JRE if one is not available. 2. If JRE is already installed on your system and you just want to activate your browser, do the following steps. a. Go to your system's Control Panel > Java Plug-in > Browser b. Enable the browser(s) for Java Plug-in. c. Test your browser(s) to see if the correct Java Plug-in is being used. Basic Installation Procedures The following table lists the basic installation tasks in the order in which they should be performed and shows the page numbers where the tasks are described in more detail. Table 2-3: CS Basic Installation Tasks Task Where Documented Mount the CS “Mounting the CS” on page 35 Make an Ethernet connection “Making an Ethernet Connection” on page 35 Connect servers and other devices to be managed through the CS “Connecting Servers and Other Devices to CS” on page 36 Make a direct (terminal) connection to prepare CS for basic network configuration “Making a Direct Connection to Configure the Network Parameters.” on page 37 Power on the CS and the connected devices “Powering on the CS and the Connected Devices” on page 37 Perform basic network configuration “Performing Basic Network Configuration Using the wiz Command” on page 38 Select a security profile using the web manager “Selecting A Security Profile Using the Web Manager” on page 43

BLACK BOX® CS Installation, Administration, and User’s Guide

35 Basic Installation Procedures Mounting the CS You can mount the CS on a wall, rack, or cabinet, or place it on a desktop or other flat surface. Two brackets are supplied with six hex screws for attaching the brackets to CS for mounting. See item 14 in the shipping content section. • If you are not mounting the CS, place the unit on a desk or table. • If you are rack-mounting the CS, obtain a hex screwdriver and appropriate nuts and bolts before starting the following procedure. T To rack-mount CS, perform the following steps: 1. Install the brackets on to the front or back edges of the box using a screw driver and the screws provided with the mounting kit. 2. Mount the CS box in a secure position. Note: To ensure safety refer to Appendix B: Safety Guidelines. Making an Ethernet Connection You can use the RJ-45 straight-through cable and the appropriate adapter provided in the product box to assemble a console cable. All adapters have an RJ-45 connector on one end and either a DB25 or DB9 male or female connector on the other end. brackets

Installation and Configuration

36 T To Make an Ethernet Connection 1. Connect the RJ-45 end of the cable to the port labeled “Console” on the CS. 2. Connect the adapter end of the cable to the console port of your server or device. 3. Connect a patch cable from the CS port labeled 10/100Base-T to an Ethernet hub or switch. Connecting Servers and Other Devices to CS The following sections describes the recommended preparation for connecting servers or devices to CS. • Make sure the configuration on servers or devices to be connected are completed. • Work with the administrator of the servers or devices to ensure all the following prerequisites are met: • All devices are installed and fully configured. • User accounts exist for the users who need access to the server or device. • If a device is to use remote authentication, make sure that the authentication servers are installed and fully configured • You have obtained from the server’s administrator the information (IP address and other method-specific information), which you need to configure the authentication server on the CS. T To Connect Devices to Serial Ports Using patch cables with RJ-45 connectors and DB-9 console adapters assemble crossover cables to connect the CS serial ports to the device’s console port. Note: After CS is installed make sure to specify the desired authentication method to CS and the serial ports that each device is connected to. See “Authentication” on page 214 for more information on configuring authentication to CS, and “Physical Ports” on page 239 for detail information on configuring the serial ports.

BLACK BOX® CS Installation, Administration, and User’s Guide

37 Basic Installation Procedures Making a Direct Connection to Configure the Network Parameters. Perform the following steps to connect a terminal or a computer to the console port of the CS. This procedure assumes you know how to use a terminal or terminal emulation program. On a PC, ensure that HyperTerminal or another terminal emulation program is installed on the Windows operating system. On a computer running a UNIX- based operating system, such as Solaris or Linux, make sure that a compatible terminal emulator such as Kermit or Minicom is installed. T To Connect to the Console Port 1. Install and launch your serial communication software on a terminal or a computer. For example, if you are using a PC, use HyperTerminal to perform the initial configuration of the CS directly through your PC’s COM port. 2. Open HyperTerminal. Start > All Programs > Accessories > Communications > HyperTerminal 3. Start a New Connection session, select an available COM port, and enter the following console parameters. • Bits per second: 9600 bps • Data bits: 8 bits • Parity: None • Stop bit: 1 • Flow control: None Powering on the CS and the Connected Devices Do the following procedures in the order shown to avoid problems with components on connected devices. T To Power on the CS 1. Make sure the CS’s power switch is off. 2. Plug in the power cable. 3. Turn the CS’s power switch(es) on.

Installation and Configuration

38 Note: If your CS model is equipped with dual power supplies, make sure you turn both power switches on. After system initialization, a beep sound may warn if one of the power supplies is off. T To Turn Power On Connected Devices • Turn on the power switches of the connected devices only after you have completed the physical connection to CS. Configuring the Network Parameters In preparation to make CS available on the network, collect the following information from your system administrator and proceed with the network configuration procedure. • Hostname • An IP address for CS • Domain name • DNS IP address • Gateway IP address • Network mask • NTP server’s IP address (if you are using a time/date server) Performing Basic Network Configuration Using the wiz Command The following procedure assumes that a hardware connection is made between the CS’s console port and the COM port of a computer. T To Log Into CS Through the Console From your terminal emulation application, log into the console port as root. CS login: root Password: bb

BLACK BOX® CS Installation, Administration, and User’s Guide

39 Basic Installation Procedures Note: It is strongly recommended to change the default password “bb” before setting up the CS for secure access to the connected servers or devices. T To Change the root password 1. Enter the passwd command. d. Enter a new password when prompted. The following Security Advisory appears the first time CS is powered on, or when the unit is reset to factory default parameters. [root@CAS root]# passwd New password: new_password Re-enter new password: new_password Password changed

Installation and Configuration

40 Figure 2-2: Security Advisory Console Message T To Use the wiz Command to Configure Network Parameters 1. Launch the Configuration Wizard by entering the wiz command. Important - Security Advisory! Console Management provides critical access to management features of attached equipment. Please take the required precautions to understand the potential impacts this device may have to your SECURITY policies. From factory, this device is configured as follows: - single password for ROOT; - all serial port DISABLED; - DHCP, Telnet, SSHv1 & SSHv2 and HTTP & HTTPS enabled. The following actions are STRONGLY recommended: 1. To change the ROOT user's password before setting up the device. 2. That you SELECT A SECURITY PROFILE to complete the INITIAL SETUP. Security is dependent on Policy and is Configurable to fit in environments with varying levels of Security. This device provides three pre-set Security Levels: SECURED, MODERATE and OPEN, and in addition, the ability to set a CUSTOM Security Profile. 3. Do not leave the equipment idle WITHOUT selecting a SECURITY PROFILE. 4. To ENABLE Serial Ports and CONFIGURE them using Web UI or CLI. Refer to the Quick Start Guide or the User's Guide for Security Profile selection details and Serial Port configuration. [root@CAS root]# wiz

BLACK BOX® CS Installation, Administration, and User’s Guide

41 Basic Installation Procedures As shown in the sample screen below, the system brings up the configuration wizard banner and begins running the wizard. 2. At the prompt, enter n to change the defaults. 3. Press Enter to accept the default hostname, otherwise enter your own hostname. 4. Press Enter to keep DHCP enabled, or enter “n” to specify a static IP address for CS. By default, CS uses the IP address provided by the DHCP server. If your network does not use DHCP, then CS will default to 192.168.160.10. Set to defaults (y/n)[n]: n Hostname [CAS]: fremont_branch_CS Do you want to use DHCP to automatically assign an IP for your system? (y/n)[y] :

Installation and Configuration

42 5. To change the default static IP address, see your network administrator to obtain a valid IP address. 6. Enter the domain name. 7. Enter the IP address for the Primary DNS (domain name) server. 8. Enter the IP address for the gateway. 9. Enter the netmask for the subnetwork. The network configuration parameters appear. 10. Enter y after the prompts shown in the following screen example. 11. To confirm the configuration, enter the ifconfig command. 12. After the initial configuration proceed to the Web Manager to select a security profile. System IP[192.168.160.10]: CS_IP_address Domain name[blackbox.com]: domain_name Primary DNS Server[192.168.44.21] : DNS_server_IP_address Gateway IP[eth0] : gateway_IP_address Network Mask[#] : netmask Are all these parameters correct? (y/n)[n]: y Do you want to activate your configurations now? (y/n)[y]: y Do you want to save your configuration to Flash? (y/n)[n]: y

BLACK BOX® CS Installation, Administration, and User’s Guide

43 Basic Installation Procedures Note: To use the Web Manager, ask your system administrator for the CS’s IP address. CS may be set up with a static IP address at your site. By default, CS uses the IP address provided by the DHCP server. If your network does not use DHCP, then CS defaults to 192.168.160.10. Selecting A Security Profile Using the Web Manager After the initial configuration, connect to the Web Manager by entering the IP address of the CS in a supported browser. Note: Once you login to the Web Manager, a Security Profile must be selected in order to further configure CS using the Web Manager. For this reason your browser redirects to Wizard > Step1: Security Profiles. T To Select a Security Profile Select a pre-defined Security Profile, or define a Custom profile for specific services. The profiles are: • Secured: Disables all protocols except SSHv2, HTTPS, and SSH to Serial Ports. • Moderate: Enables SSHv1, SSHv2, HTTP, HTTPS, Telnet, SSH and Raw connections to Serial Ports, ICMP, and HTTP redirection to HTTPS. • Open: Enables all services, Telnet, SSHv1, SSHv2, HTTP, HTTPS, SNMP, RPC, ICMP and Telnet, SSH and Raw connections to Serial Ports. • Default: Sets the profile to the same configuration as Moderate. • Custom: Enable or disable individual protocols and services, and configure access to ports. For detailed information on Security Profiles see “Security Profiles” on page 226. The administrator can perform the following tasks using the Web Manager. • Administer CS and its connected devices. • Configure user and group permissions.

Installation and Configuration

44 • Access the serial ports and the connected devices. Adding Users and Configuring Ports Using the Web Manager Enabling Ports and Assigning Users. Note: From the factory, CS is configured with all serial ports disabled. • The administrator can add users, enable or disable the serial ports, and select and assign specific users to individual ports. For detailed information on managing users and ports see Appendix 9, “Security Menu & Forms" and Appendix 10, “Ports Menu & Forms". For additional configuration and administration options, and other important related information, see the chapters in the CS user manual that are listed in the following table. Topic Where Documented Installation and Configuration Process. Appendix 2, “Installation and Configuration" For Regular Users - How to use the Web Manager to access servers and connected devices. Appendix 3, “Web Manager for Regular Users" Web Manager in Wizard Mode. Appendix 5, “Configuring CS in Wizard Mode" Web Manager in Expert Mode. Appendix 6, “Configuring the CS in Expert Mode"

BLACK BOX® CS Installation, Administration, and User’s Guide

45 Other Methods of Accessing the Web Manager Other Methods of Accessing the Web Manager You can access the Web Manager using one of the following methods. Note: The following methods require additional setup and configuration, which could be specific to your site’s network configuration. • Using DHCP • Using the default IP address T To Use a Dynamic IP Address to Access the Web Manager This procedure assumes that DHCP is enabled, and that you are able to obtain the dynamic IP address that is currently assigned to CS. 1. Mount the BLACK BOX® CS. 2. Connect computers and other devices to be managed through the CS. 3. Power on the CS and connected devices. 4. Obtain the CS’s current IP address. 5. Enter the CS’s IP address in the browser’s Address window. 6. Login to the CS and finish configuring users and other settings using the Web Manager. T To Use the Default IP Address to Access the Web Manager The default IP address for the CS is 192.168.160.10. This procedure assumes that you are able to temporarily change the IP address of a computer that is on the same subnet as the CS. 1. On a computer that resides on the same subnet as the CS, change the network portion of the IP address of that computer to 192.168.160. For example, you could change the computer’s IP address to 192.168.160.44. For the host portion of the IP address, you can use any number except 10, 0, or 255.

Installation and Configuration

46 2. Bring up a browser on the computer whose address you changed, enter the CS’s default IP address, http://192.168.160.10 to bring up the Web Manager, and log in. Installing PCMCIA Cards The front panel of the CS has two PCMCIA card slots as shown in the following figure. You can insert and configure one card in each of the slots. See Appendix C, “Supported PCMCIA Cards". Figure 2-3: Front Panel PCMCIA Card Slots T To Install a PCMCIA Card 1. Insert the PCMCIA card into slot 1 or slot 2. 2. Use the Web Manager to configure the PCMCIA card. Note: A hard disk PCMCIA card is automatically mounted once it is inserted, and it needs no configuration. T To Remove a PCMCIA Card Caution: Always use the Web Manager to eject a PCMCIA card. Any other method may cause a kernel panic. 1. Eject the card by using the Eject button on the Web Manager’s PCMCIA Management form, Expert > Network > PCMCIA Management > Eject PCMCIA Slots

BLACK BOX® CS Installation, Administration, and User’s Guide

47 Connecting AlterPath PM IPDUs Figure 2-4: PCMCIA Eject Button in Web Manager 2. Physically remove the card from the slot. T To Configure a PCMCIA Card See Chapter 8, “To Configure a PCMCIA Card”, and the sections related to the type of card you need to configure. Connecting AlterPath PM IPDUs You can connect AlterPath Power Management (PM) intelligent power distribution units (IPDUs) to the serial ports on the CS using an RJ-45 to RJ- 45 UTP cable. AlterPath PM includes two RS-232 outlets for serial management and daisy-chaining. Any combination of Alter PM models up to 128 outlets can be daisy-chained into a single virtual power distribution unit. The following figure shows an CS and two AlterPath PM8 IPDUs daisy- chained. One PM is connected to a serial port on CS configured for power management, and a second PM is daisy-chained from the first PM.

Installation and Configuration

48 Figure 2-5: AlterPath PMs Connected to the CS The following table lists the related tasks on connecting IPDU units and managing power. T To Daisy-Chain AlterPath PMs to the CS This procedure assumes that you have one AlterPath PM connected to a serial port on the CS. 1. Connect one end of a UTP cable with RJ-45 connectors to the “OUT” port of the AlterPath PM that is connected to the serial port on CS. 2. Connect the other end of the cable to the “IN” port of the next AlterPath PM. 3. Repeat Steps 1 and 2 until you have connected the desired number of AlterPath PMs. Table 2-4: Tasks Related to Connecting AlterPath PMs Task Where Documented Configure serial ports for power management protocol. “To Configure a Serial Port for IPDU or IPMI Power Management” on page 274 How the administrators perform IPDU power management using the Web Manager “IPDU Power Mgmt.” on page 120 How the regular users manager power outlets using the Web Manager “To Close an SSH Session” on page 56 Connect the AlterPath PM to the CS unit, and daisy-chain multiple PM units. “To Daisy-Chain AlterPath PMs to the CS” on page 48 Configure users for IPDU power management “To Configure Users to Manage Power Outlets on IPDUs” on page 128 Configure servers for IPMI power management while connected. “To Delete, Add, or Edit an IPMI Device to Enable or Disable IPMI Power Management” on page 142

Web Manager for Regular Users

This chapter describes the requirements and the procedures for “Regular Users” to use the Web Manager. Regular users are those who have configured accounts on the CS with limited access rights. Regular users can perform the following tasks using the Web Manager. • Access computers and devices that are connected to the serial ports on the CS. • Perform IPDU power management. • Change their current password. This chapter contains the following sections. Using the Web Manager CS users perform most tasks through the Web Manager. The Web Manager runs in a browser and provides a real-time view of all the equipment that is connected to the CS. Using the Web Manager Page 49 Features of Regular User Forms Page 51 Connect Form Page 52 IPDU Power Management Page 56 IPDU Multi-Outlet Control Page 60 Security Page 63

Web Manager for Regular Users

50 The CS administrator can use the Web Manager to configure users and ports. An authorized user can access connected devices through the Web Manager to troubleshoot, maintain, recycle power, and reboot connected devices. T Logging in to the Web Manager 1. Connect your web browser to CS by typing in the Console Access Server’s IP address (e.g., https://10.10.10.10) provided to you by your system administrator in your internet browser. Note: Refer to Chapter 2, “ for the requirements to start with the Web Manager. Press Enter. The system brings up the CS Web Manager Login form. 2. Type in your username and password as provided to you by your system administrator. Figure 3-1: Regular User > Web Manager Login form

BLACK BOX® CS Installation, Administration, and User’s Guide

51 Features of Regular User Forms Features of Regular User Forms The following figure shows features of the Web Manager when regular users log in. Figure 3-2: Regular User Form The form in the middle changes according to which menu option is selected. The following table illustrates the functions that are common to all the forms. Table 3-1: Common Screen Information Form Area Purpose Click this button to log out. Form area Menu Logout button and CS information area

Web Manager for Regular Users

52 Connect When you select the “Connect” option, the following form appears. Figure 3-3: Regular User > Connect Form You can use this form to connect to the CS console, or to one of the serial ports as described in the following sections. • “Connect to CS” on page 53 • “Connect to Serial Ports” on page 54 Permission to access a port or perform power management is granted by the CS administrator when your user account is created. Contact your administrator to gain authorization to access the serial port that the server or devices is connected to. Displays the hostname and IP address assigned during initial configuration, and the model number of the CS. Brings up the online help. Table 3-1: Common Screen Information (Continued) Form Area Purpose

BLACK BOX® CS Installation, Administration, and User’s Guide

53 Connect Connect to CS When you click the “Connect to CS” radio button on the “Connect” form, a Java applet viewer appears running an SSH session on the CS. The following figure shows the Java applet when you connect to the CS. Note in the “Connected to” message in the below figure at the top of the screen the IP address of the CS followed by the session type, in this case “SSH”. Figure 3-4: Java Applet The following table describes the available buttons in the Java applet: Table 3-2: Java Applet Buttons Button Purpose To send a break to the terminal

Web Manager for Regular Users

54 Connect to Serial Ports The list of serial ports includes the port names or administrator-defined aliases only for ports you have permission to access. If the list is empty or does not include a port you need to access, contact the CS system administrator. Port Access Requirements When you connect to a serial port to access a server or another device, access rights to the specific serial port on CS is required. Your system administrator can help with authorization to specific CS ports that your server or device is connected to. Note: If an authentication server is setup in your network, an authentication method and the related parameters should be setup to allow access to the connected devices. Consult your system administrator for configuring the authentication method. When you select a port from the Serial pull-down list and click the Connect button, a Java applet viewer appears. A “Connected to” message in a gray area at the top of the screen shows the IP address of the CS followed by the TCP port number. See an example of the Java applet in Figure 3-4 Connection Protocols for Serial Ports You can access a server or a device connected to a serial port by using the connection protocol specified for the port. There are a number of connection protocols for the serial ports, which your system administrator can setup To disconnect from the Java applet Select the left icon to reconnect to the server or device; or select the right icon to end the session and disconnect from the Java applet. Table 3-2: (Continued)Java Applet Buttons Button Purpose

BLACK BOX® CS Installation, Administration, and User’s Guide

55 Connect depending on your requirements. The following table shows the protocols the CS administrator can choose for the serial ports. TCP Port Numbers for Serial Ports The TCP port numbers by default start at 7001 for serial port 1 and increments up to the number of serial ports that your CS unit has. For example, an CS with 8 serial ports have TCP ports 7001 through 7008. The CS administrator may change the default port numbers, so if you use the defaults and they fail, check with the administrator to find which port numbers to use. T To Use Telnet to Connect to a Device Through a Serial Port For this procedure, you need the hostname of the CS or its IP address and the TCP port number for the serial port to which the device is connected. • To use Telnet in a shell, enter the following command: T To Close a Telnet Session Enter the Telnet hotkey defined for the client. The default is “Ctrl ]” and “q” to quit. Table 3-3: Serial Ports Connection Protocols Connection Type Protocol Console Access Server (CAS) Telnet, SSH, Telnet&SSH, Raw Terminal Server (TS) Telnet, SSHv1, SSHv2, Local Terminal, Raw Socket Dial-up PPP-No Auth., PPP, SLIP, CSLIP Other Power Management, Bi-directional Telnet telnet hostname | IP_address TCP_port_number

Web Manager for Regular Users

56 T To Use SSH to Connect to a Device Through a Serial Port For this procedure, you need the username configured to access the serial port, the TCP port number, and the hostname of the CS or its IP address. • To use SSH in a shell, enter the following command: T To Close an SSH Session Enter the hotkey defined for the SSH client followed by a dot “.”. The default is “~.” Note: Make sure you enter the escape character followed by a “.” at the beginning of a line to close the SSH session. IPDU Power Mgmt. IPDU or “Intelligent Power Distribution Units” management allows you to manage the power outlets on the AlterPath PM products. When you select the “IPDU Power Mgmt.” option, if you have permission to manage outlets on an AlterPath PM, two tabs appear at the top of the form, as shown in the following figure, “Outlets Manager” and “View IPDUs Info”. Figure 3-5: Regular User > IPDU Power Mgmt. Forms You can access the forms under IPDU Power Mgmt. menu to manage outlets, or view IPDUs information: ssh -l username:TCP_port_number CS_IP_address

BLACK BOX® CS Installation, Administration, and User’s Guide

57 IPDU Power Mgmt. Outlets Manager When you go to IPDU Power Mgmt.>Outlets Manager tab, the message shown in the following figure appears if, 1- You do not have permission to manage power on any of the AlterPath PM outlets or, 2- CS cannot detect an AlterPath PM that has been configured for power management. Contact the CS administrator for help, if you see this message. Figure 3-6: Regular User > Outlets Manager (no permissions) The following form appears if you have permission to manage power on one or more outlets of the AlterPath PM. Figure 3-7: Regular User > Outlets Manager (with permissions)

Web Manager for Regular Users

58 The form shows separate entries for each serial port configured for power management, a name for the configured serial port if one is defined by the administrator, and the number of IPDUs connected. The matrix displays a line item for each outlet you are authorized to manage. The authorized user can do the following for any listed outlet: • Edit the outlet name. Enter a name to identify the server or device plugged into the outlet. • Edit the power up interval. The power up interval is the time interval (in seconds) that the system waits between turning on the currently-selected outlet and the next outlet. The default is set at 30 seconds. • Cycle - Turn power briefly off and on again. • Turn the power On/Off to the outlet. • Lock or unlock the outlet to prevent accidental changes to the power state. The following table describe the corresponding buttons to do the above operations: Table 3-4: Regular User > Outlet Management Buttons Button Purpose Opens a dialog box to Edit an Outlet name, and the Power Up Interval. Turn power briefly off and then on again. Turn power On/Off. Lock or unlock the outlet.

BLACK BOX® CS Installation, Administration, and User’s Guide

59 IPDU Power Mgmt. View IPDUs Info When you go to IPDU Power Mgmt.>View IPDUs Info, the form appears as shown in the following figure. Figure 3-8: Regular User > View IPDUs Info The following information is displayed for each port that is configured for power management. Table 3-5: Regular User > Information on the View IPDUs Info Form Description Example Name Either a default name or administrator-configured name. PM Number of Units The number of IPDUs connected to the port. The first IPDU is referred to as the master. Any other IPDUs daisy-chained off the first IPDU are referred to as slaves. 1 Syslog Whether syslogging has been configured for messages from this IPDU. ON Buzzer Whether a buzzer has been configured to sound when a specified alarm threshold is exceeded. ON Number of Outlets Total number of outlets on all connected IPDUs. 8

Web Manager for Regular Users

60 IPDU Multi-Outlet Ctrl Selecting IPDU Multi-Outlet Control form allows you to view and manage the power on a group of outlets that provide power to a multi power supply server or device connected to a serial port. Whether the outlets that the multi Over Current Protection Whether over current protection is enabled (to prevent outlets from being turned on if the current on the IPDU exceeds the specified threshold). OFF Description Example Model AlterPath PM model number PM8 15A Software Version PM firmware version 1.5.0 Alarm Threshold Number of amperes that triggers an alarm or syslog message if it is reached 15.0A Current Current level on the IPDU 0.0A Maximum Detected Maximum current detected 0.4A Use this button to refresh the currently displayed maximum detected temperature. Temperature Temperature on the AlterPath PM (Available only on selected models that have temperature sensors) Maximum Detected Maximum temperature detected (Available only on selected models that have temperature sensors) Use this button to refresh the currently displayed maximum detected current. Table 3-5: Regular User > Information on the View IPDUs Info Form Description Example

BLACK BOX® CS Installation, Administration, and User’s Guide

61 IPDU Multi-Outlet Ctrl power supply device is connected to are on the same PM or not, the outlets can be grouped together and managed simultaneously from this form. When you select IPDU Multi-Outlet Ctrl form, the following figure appears if, 1. There is no multi-outlet device defined. 2. Power Management is not enabled for the serial port the device is connected to. 3. CS cannot detect an AlterPath PM that has been configured for power management. Contact the CS administrator for help, if you see this message. Figure 3-9: Regular User > IPDU Multi-Outlet (no permissions) The following form appears if you have permission to view and control the outlets that a multi power supply server or device is connected to.

Web Manager for Regular Users

62 Figure 3-10: Regular User > IPDU Multi-Outlet (with permissions) Notice in the above figure that the first line of each group, the light bulb, the lock icon, and the Cycle button operate over the entire group. The light bulb and lock icons next to the individual outlets are used to display the status of each outlet but cannot be used to control the individual outlets. The following table describes the icons in the first line of each group. Table 3-6: Regular User > IPDU Multi-Outlet Ctrl. Form Icons Note: Only one outlet needs to be powered on or unlocked in order for the entire group to be considered on or unlocked respectively. In this case, it takes two clicks to turn the power off or to lock the entire group instead of the one click, when all of the outlets are in the same state. The first click turns the other outlets on or unlocks them so that all the outlets are in the same state; the second click turns all of the outlets off or locks them. The Cycle button operates only if all outlets of a group are turned on. Note: The “PU (Power Up) interval" parameter configured for each outlet plays an important role in the power up sequence of multi-outlet devices. The next Button Purpose A grey light bulb icon indicates that the group is off. A yellow light bulb indicates that the group is on. Clicking the light bulb icon changes the power status of all of the outlets in the group. A grey and open lock icon indicates that the outlets are unlocked and can be powered on or off. A full-color and closed lock icon indicates that the outlet is locked and cannot be turned on or off. Clicking the lock icon changes the lock status of all of the icons in the group. Turn power briefly off and on again

BLACK BOX® CS Installation, Administration, and User’s Guide

63 Security outlet in the group turns on only after the power up interval specified for the current outlet has elapsed. This parameter can be configured through the IPDU Power Mgmt. form. See “To Close an SSH Session” on page 56. Security When you select the “Security” menu option, the following form appears. . Table 3-7: Regular User > Password Management Form T To Change Your Password 1. Select the “Security” option from the menu panel. The “Security” form appears. 2. Enter your current password in the “Current Password” field. 3. Enter the new password in the “New Password” and the “Repeat New Password” fields. 4. Click OK. 5. Log out and log in using your new password to verify your password change.

Web Manager for Administrators

Overview This chapter is for system administrators who use the Web Manager to configure the CS and its users. For information on how to configure CS using vi or Command Line Interface (CLI), please consult the BLACK BOX® CS Installation, Administration, and User’s Guide. The CS Web Manager for administrators describes two modes of operation, Wizard and Expert. This chapter provides an overview of the Web Manager forms. The subsequent chapters describe the menus, forms, and the configuration procedures of the Web Manager in Wizard and Expert modes. If you are a regular user see Chapter 3, “Web Manager for Regular Users”. The sections listed in the following table provides background information related to CS administrators’ use of the Web Manager, including explanations of the types of information to be entered in each of the forms, and links to all the procedures performed in each mode. BLACK BOX® Web Manager Page 66 Common Tasks for CS Administrators Page 67 Common Features of Administrators’ forms Page 68 Logging into the Web Manager Page 70 Overview of Administrative Modes Page 73

Web Manager for Administrators

66 BLACK BOX® Web Manager CS administrators perform most tasks through the BLACK BOX® Web Manager either locally or from a remote location. The Web Manager provides a real-time view of the equipment that is connected to the CS. The CS administrator can use the Web Manager to configure users and ports. An authorized user can access connected devices through the Web Manager to troubleshoot, maintain, recycle power, and reboot connected devices. Access to the Web Manager can be through any of the following methods: • Through an Ethernet protocol network. • Through a dial-up protocol such as: • An optional modem connected to one of the serial ports. • An optional modem card inserted into one of the PCMCIA slots. • An optional CDMA wireless, GSM, or ISDN card. Prerequisites for Using the Web Manager The prerequisites described in this section must be completed before anyone can access the Web Manager. If you have questions about any of the following prerequisites, contact your system or network administrator. • Basic network parameters must be defined on the CS so the Web Manager can be launched over the network. • The IP address of the CS must be known. Note: If DHCP is enabled on CS, the IP address is not fixed. Anyone wanting to access the CS must find out the currently-assigned IP address each time. If DHCP is enabled and you do not know how to find out the current IP address of the CS, contact your system administrator for help. • A user account must be defined on the Web Manager. By default, the “root” has an account on the Web Manager. An administrator with “root” access can add regular user accounts to access connected devices.

BLACK BOX® CS Installation, Administration, and User’s Guide

67 Common Tasks for CS Administrators Common Tasks for CS Administrators The following table shows some of the common tasks that are performed by an administrator and links to the process and procedure for performing the task. Table 4-1: Administrator > Common Administrative Tasks Task Where Documented Set up users and groups to access connected devices. “Users and Groups” on page 208 Set up user authentication to access serial ports. “Access” on page 259 Configure serial ports for power management. “To Configure a Power Management Protocol for an IPDU” on page 254 Assign users permissions to manage outlets on connected AlterPath PMs. “To Configure Users to Manage Power Outlets on IPDUs” on page 128 Set up local or remote data buffering, and specify alarms for one or more serial ports. “To Configure Data Buffering for Serial Ports” on page 267 “To Choose a Method for Sending Notifications for Serial Port Data Buffering Events” on page 297 Set up logging of system messages to a syslog server. “To Specify Names, Alarms, Syslogging, and Over Current Protection for IPDUs” on page 130 “To Configure Syslogging for Serial Ports and Specify Message Filtering” on page 158“ Configure devices for IPMI power management. “IPMI Power Management” on page 139 Select an authentication method for accessing connected devices. “Authentication” on page 214 Configure packet filtering. “Firewall Configuration” on page 186

Web Manager for Administrators

68 Common Features of Administrator Forms The common features of all Web Manager forms for CS administrators are described in the following sections. • Buttons and CS Information • Getting more information Buttons and CS Information The following figure shows the control buttons that display at the bottom of the form when the logged in user is an administrator. Figure 4-1: Administrator > Web Manager Buttons The following table describes the uses for each control button. Table 4-2: Administrator > Web Manager Buttons Button Name Use back Only appears in Wizard mode. Returns the previous form. try changes Tests the changes entered on the current form without saving them. cancel changes Cancels all unsaved changes. apply changes Applies all unsaved changes. reload page Reloads the page. Help Brings up the online help. next Only appears in Wizard mode. Goes to the next form.

BLACK BOX® CS Installation, Administration, and User’s Guide

69 Common Features of Administrator Forms The various Web Manager actions for trying, saving, and restoring configuration changes are summarized in the following table. The unsaved changes button appears on the lower right hand corner of the Web Manager and a graphical LED blinks red whenever the current user has made any changes and has not yet saved the changes. The no unsaved changes button appears and a graphical LED appears in green when no changes have been made that need to be saved. Table 4-3: Administrator > Options for Trying, Saving, and Restoring Configuration Changes Task Action Result try changes Click the “try changes” button” Updates the appropriate configuration files. Changes are preserved if you log in and log out, and even if you restart the system. Changes stay in effect unless the “cancel changes” button is clicked. The changes can be restored at any time until the “apply changes” button is clicked. cancel changes Click the “cancel changes” button Restores the configuration files from the backup that was created the last time changes were applied. apply changes Click the “apply changes” button If “try changes” has not been previously clicked, updates the appropriate configuration files. Overwrites the backed up copy of the configuration files. Table 4-2: Administrator > Web Manager Buttons Button Name Use

Web Manager for Administrators

70 The following table illustrates the information that displays in the upper right corner of all Web Manager forms. Logging Into the Web Manager The following procedure describes the login process to the Web Manager, and what should be expected the first time you login to CS. TTo Log Into the Web Manager 1 To bring up the Web Manager, enter the IP address of the CS in the address field of your browser. For example, http://192.168.48.11 Note: Devices such as CS are usually assigned a static IP addresses. If DHCP is enabled, you must find out the dynamically-assigned IP address each time you need to run the Web Manager. Finding a dynamically-assigned IP address requires making an inquiry to the DHCP server using the MAC address (a 12- digit hexadecimal number, which is on a label on CS). Check with the system administrator who configured the basic network parameters on the assigned IP address. If there is no DHCP server, use the default static IP address 192.168.160.10 that is pre-configured in the CS. a. If DHCP is disabled, use a static IP address assigned by the administrator. b. If DHCP is enabled, enter the dynamically-assigned IP address. The Login page appears. Table 4-4: Administrator > Logout Button and Other Information in the Upper Right Form Area Purpose Click this button to log out. Displays the hostname, IP address assigned during initial configuration, and the model number of the Advanced Console Server.

Other Server Manuals