2080E-T MANAGED ETHERNET SWITCH INSTALLATION GUIDE
©2013 Cooper Bussmann
www.cooperbussmann.com/wirelessresources
10/16
Page 1 of 2
Version 1.0
Power Input and Fault Alarm Contact Wire Gauge: 12–24 AWG RJ-45.
Port Connection: Use four twisted pair Cat 5, 5e, or 6 cables less than 100 meters long.
NOTE This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D or
non-hazardous locations only.
WARNING – EXPLOSION HAZARD!
• Do not disconnect equipment while the circuit is live unless the area is known to be free
of ignitable concentrations.
• Do not disconnect equipment unless power has been removed or the area is know to be
non-hazardous.
• Substitution of any components may impair suitability for Class I, Division 2.
• The area must be known to be non-hazardous before servicing or replacing the unit and
before installing the unit.
WARNING Exposure to some chemicals may degrade the sealing properties of materials used
in the sealed relay device. It is recommended to inspect the sealed relay device periodically
and to check for any degradation of the materials and replace the complete product (not the
sealed device) if any degradation is found.
Terminal Block for Power 1,
Power 2 and Fault Alarm Contact
RS-232 Console Port
10/100 TX RJ-45 Ethernet Ports (8)
1. Insert DC power wires into the contacts for Power Supply 1 and 2.
2. Tighten the terminal screws to ensure that the wires do not come loose.
Power Supply 2*
Power Supply 1
*Power Supply 2 is used for
redundant supplies.
Surge EARTH
POWER SUPPLY WIRING
DC Power Input Range:
12VDC–48VDC
FAULT CONTACT WIRING
2080E-T
2080E-T
Surge EARTH
FAULT ALARM
CONTACT 1A@24V
N/C Contact
Contact will open
when a fault occurs
DC
DC
2080E-T MANAGED ETHERNET SWITCH INSTALLATION GUIDE
10/16
Page 2 of 2
Version 1.0
©2013 Cooper Bussmann
www.cooperbussmann.com/wirelessresources
Pin Connections
DB-9 Female
RJ-45
Pin - 2
2 - Orange
Pin - 3
3 - Green/White
Pin - 5
5 - Blue/White
Other Pins - NC
Other Pins - NC
RS-232 Connection Setting:
9600 baud, 8 bits, no parity,
1 stop bit, no flow control
RS-232 CONSOLE PORT CABLE
DIN-RAIL MOUNTING
1. Insert the top of the DIN rail clip
onto the DIN rail.
2. Press the 2080E-T onto the DIN rail
until it clicks into place.
3. Check that the module is securely attached to the DIN rail.
4. To remove the 2080E-T from the DIN rail, press down on the rear top
of the module and swing the bottom of the module forward.
WALL MOUNT PLATE MOUNTING
1. Remove the DIN rail from the 2080E-T by
loosening the three screws.
2. Place the wall mount plates on the rear panel of
the 2080E-T.
3. Use six screws to screw the wall mount plates
onto the 2080E-T.
4. Use the hook holes at the corners of the wall
mount plates to mount the 2080E-T on the wall.
5. To remove the 2080E-T from the wall, reverse
these steps.
RS-232 DB-9 Female
RJ-45