Text of the manual

Montage- und Gebrauchsanweisung

Installatie- en gebruksaanwijzing Manuel de montage et d’utilisation Operating and Installation Instructions

for kitchen unit installer

Introduction 59 Extractor version Filter version Hood operation 60 Maintenance and care 61 Metal grease filter Carbon filter Changing the light bulb Cleaning Special accessories Technical assistance service Guarantee conditions Service Technic Details 67 Installation 68 Electrical connection Wall unit mounting Wall mounting

for kitchen unit installer

G When used as an extractor unit, the hood must be fitted with a 120mm diameter hose. G If the fumes must be forced out through the wall, you must obtain a MKZ sizable wall exhaust pipe (with external exhaust and air intake), E-Nr.- 610 899 004 (Ø 120 mm) which is one of our optio- nal parts. G When installing the hood, make sure you respect the follow- ing minimum distance from the top edge of the cooking hob/ ring surfaces: electric cookers 600 mm gas cookers 650 mm coal and oil cookers 700 mm min. Safety warnings for user G Always cover lighted elements, to prevent excess heat from damaging the appliance. In the case of oil, gas and coal fired cookers it is essential to avoid open flames. G Also, when frying, keep the deep frying pan on the cooker top/ cooker under careful control. G The hot oil in the frying pan might ignite due to overheating. G The risk of self-ignition increases when the oil being used is dirty. G It is extremely important to note that overheating can cause a fire. G Never carry out any flambé cooking under the hood. G Always disconnect the unit from the power supply before carrying out any work on the hood, including replacing the light bulb (take the cartridge fuse out of the fuse holder or switch off the automatic circuit breaker). G It is very important to clean the hood and replace the filter at the recommended intervals. Failure to do so could cause grease deposits to build up, causing a fire hazard.

G The national decree on fuel-burning systems specifies a

maximum depression of 0.04 bar in such rooms. G The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circum- stances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed. G It is advisable to apply for authorization from the relevant controlling authority when connecting the outlet to an unused chimney flue or combustion gas duct. The air outlet installation must comply with the regulations laid down by the relevant authorities. G When the unit is used in its extractor version, a sufficiently large ventilation hole must be provided, with dimensions that are approximately the same as the outlet hole. G National and regional building regulations impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room. G Hoods can only be used safely with appliances connected to a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approxi- mately 500-600 cm2 large to avoid the possibility of a depression being created during operation of the hood. G If you have any doubts, contact the relevant controlling authority or building inspector’s office. G Since the rule for rooms with fuel burning appliances is “outlet hole of the same size as the ventilation hole”, a hole of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood. G If the hood is used in its filtering function, it will operate simply and safely in the above conditions without the need for any of the aforementioned measures. G When the hood is used in its extractor function, the following rules must be followed to obtain optimal operation: — short and straight outlet hose — keep bends in outlet hose to a minimum — never install the hoses with an acute angle, they must always follow a gentle curve only — keep the hose as large as possible (120 mm Ø min.). G Failure to observe these basic rules will drastically reduce the performance and increase the noise levels of the extractor hood.

 The hood is supplied as an extractor unit and can also be used with

a filtering function by fitting one activated carbon filter (special accessory).  You will need original AEG activated carbon filter for this function (see Special Accessories).  The unit features two outlet holes, one of which A is located on the top of the unit while the other B is located on the rear.  To connect up the hose, you should first fit the bayonet-mounting flange C (Ø 120 mm) on the outlet required (if using the top outlet, fix the flange in place using the screw supplied as shown in Fig. 1). Close off the unused hole using the bayonet fitting caps D. Fig. 1  Warning! If is decided to use the rear outlet hole B, first remove the sponge E that closes that hole. Fig. 2. Filter Version  The air is filtered and recirculated through the front grid.  Move the lever G to position F - Fig. 3. G You will need an original AEG KF14 activated carbon filter for the filtering function. (See Special Accessories). Fig. 2 Fig. 3

G Best results are obtained by using a low speed for normal

conditions and high speed when odours are more concentrated. Turn the hood on a few minutes before you start cooking then you will get an underpressure in the kitchen. It should be left on after cooking for about 15 minutes or until all odours have disappeared. The control switches are located on the unit’s front panel: A: Main switch, hood on/off. B: Start and choice of motor speed 1-2-3-1-2......... C: Indicates speed 1 (LED). D: Indicates speed 2 (LED). E: Indicates speed 3 (LED). F: Indicates Intensive speed (LED). G: Intensive speed on/off. The Intensive speed runs for 5 minutes: - If the hood is on when the Intensive speed is activated, the hood revert to previous speed after 5 minutes. - If the hood is off when the Intensive speed is activated, the hood will automaticly be turned off after 5 minutes. To interrupt the Intensive speed, press button A or B. H: Light on/off. Should the hood or the controls fail to operate: disconnect the power supply for at least 5 seconds, then turn the hood back on again.

Maintenance and care

G The hood must always be disconnected from the mains power supply before beginning any maintenance work. Metal grease filter G The purpose of the grease filters is to aspirate grease particles which form during cooking and it must always be used, either in the external evacuation or internal recycling function. Attention: the metal grease filters must be removed and washed, either by hand or in the dishwasher, every four weeks. Open the metal grease filter  First of all, push the stop Q on the metal grease filter N back, and then extract the filter by pulling downward. Fig. 4. Dishwasher machine Place grease filters in dish washer. Select most powerful washing programme and highest temperature, at least 65°C. Repeat the process. Refit the grease filters when it are dry. When washing the metal grease filter in the dishwasher a slight discoloration of the filter can occur, this does not have any impact on its performance. G Clean the inner housing using a hot detergent solution only (never use caustic detergents, abrasive powders or brushes). Fig. 4 Hand washing Soak grease filters for about one hour in hot water with a grease-loosening cleaner, then rinse off thoroughly with hot water. Repeat the process if necessary. Refit the grease filters when it are dry. Q Q N N

G The activated carbon filter should only be used if you want to use

the hood in its filtering function. G To do this you will need an original AEG activated carbon filter (see special accessories).  Cleaning/replacing the carbon filter Unlike other carbon filters, the LONGLIFE carbon filter can be cleaned and reactivated. At normal use the filter should be cleaned every second month. The best way to clean the filter is in the dishwasher. Use normal detergent and choose the highest tempe- rature (65º C). Wash the filter separately so that no food parts gets stuck on the filter and later causes bad odours. To reactivate the carbon, the filter should be dried in an oven for 10 minutes with a temperature of maximum 100º C. After approximately three years of use, the carbon filter should be replaced with a new, as the odour reduction capacity will be reduced.  Mounting Remove the grease filters and fit one LONG LIFE carbon filter S on the rear side of each grease filter, fix each with two metal wires Z . Fig. 5. G To dismount proceed in reverse order. G Always specify the hood model code number and serial number when ordering replacement filters. This information is shown on the registration plate located on the inside of the unit. G The activated carbon filter can be ordered from the AEG technical assistance service. Fig. 5

G Failure to observe the instructions on cleaning the unit and

changing the filters will cause a fire hazard. You are therefore strongly recommended to follow these instructions. G The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations. Changing the light bulb  Disconnect the unit from the mains power supply.  Remove the grease filters.  Replace the old light bulb with a new light bulb of the same kind.  Refit the grease filters. G If the light does not come on, make sure the bulb has been screwed in correctly before contacting the technical assistance service.

G Warning: always disconnect the hood from the mains power supply

before cleaning it. Never insert pointed objects in the motor’s protective grid. G Wash the outside surfaces using a delicate detergent solution. Never use caustic detergents or abrasive brushes or powders. G Only ever clean the switch panel and filter grille using a damp cloth and delicate detergents. G It is extremely important to clean the unit and change the filters at the recommended intervals. Failure to do so will cause grease deposits to build up that could constitute a fire hazard. Special accessories Carbon filter KF 14 E-Nr. 942 120 604 Technical assistance service You are welcome to telephone our technical assistance service (see list of technical assistance centres) whenever you need information or in the unlikely event of a fault. When calling, please be ready to specify: 1. The model code number 2. The serial number (E-Nr.) 3. The manufacturing number (F-Nr.) This information is shown on the registration plate inside the unit behind the grease filter. We reserve the right to change specifications and colours as a result of our policy of continuing technological development.

AEG offer the following guarantee to the first purchaser of this appliance.

1. The guarantee is valid for 12 months commencing when the appliance is handed over to the first retail purchaser, which must be verified by purchase invoice or similar documentation.The guarantee does not cover commercial use. 2. The guarantee covers all parts or components which fail due to faulty workmanship or faulty materials. The guarantee does not cover appliances where defects or poor performance are due to misuse, accidental damage, neglect, faulty installation, unauthorised modification or attempted repair, commercial use or failure to observe requirements and recommendations set out in the instruction book.This guarantee does not cover such parts as light bulbs, removable glass-ware or plastic. 3. Should guarantee repairs be necessary the purchaser must inform the nearest customer service office (manufacturer`s service or authorised agent). AEG reserves the right to stipulate the place of the repair (i.e.the customer`s home, place of installation or AEG workshop). 4. The guarantee or free replacement includes both labour and materials. 5. Repairs carried out under guarantee do not extend the guarantee period for the appliance. Parts removed during guarantee repairs become the property of AEG. 6. The purchaser`s statutory rights are not affected by this guarantee. European Guarantee If you should move to another country within Europe then your guarantee moves with you to your new home subject to the following qualifications: - The guarantee starts from the date you first purchased your product. - The guarantee is for the same period and to the same extent for labour and parts as exist in the new country of use for this brand or range of products. - This guarantee relates to you an cannot be transferred to another user. - Your new home is within the European Community (EC) or European Free Trade Area. - The product is installed and used in accordance with our instructions and is only used domestically, i.e. a normal household. - The product is installed taking into account regulations in your new country.

Before you move please contact your nearest Customer Care Centre, listed

below, to give them details of your new home.They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliances. France Senlis +33 (0) 44 62 29 29 Germany Nürnberg +49 (0) 911 323 2600 Italy Pordenone +39 (0) 1678 47053 Sweden Stockholm +46 (0) 8 738 7910 UK Slough +44 (0) 1753 219899

Height x Width x Depht (in cm)

16,3 x 59,9 x 53,5 Maximum absorbed power: 200 W Motor absorption: 120 W Lighting: 2 x 7 W Length of the cable: 115 cm

Safety warnings for the electrician

Before connecting the appliance to the power supply, check that the voltage indicated on the rating plate corresponds to the mains power supply available. Appliances fitted with a plug can be connected to any standard power socket within easy access. Should it be necessary to provide a fixed connection, the hood must only be installed by an electrician authorised by the local electricity board. When installing, an omnipolar disconnector with a distance of at least 3 mm between contacts must be provided. The manufacture declines all responsibility for malfunctions resulting from failure to comply with the above instructions. Electrical connection 220-240 V – by means of fixed power cable with plug. (Fixed connection of the appliance must only be carried out by an author- ised electrician.)

Wall unit mounting - Fig. 6

 Make the holes on the bottom of the cupboard (2), using the drilling template (1). Provide an hole also for exhausting pipe (4) ONLY if is decided to use the hood in Exhausting version (3).  From inside the cupboard, insert the 4 supplied screws (5) and tighten them in the appropriate holes on the appliance. Fig. 6

Wall mounting - Fig. 7

G Sign a centerline onto the wall (1). Fit the template onto the wall (2). G Fix the drilling template to the wall. G Make 3 Ø 8mm holes in the wall (3), 2 at upper points, 1 as desired at lower points. G Insert the three Ø 8mm expansion plugs into the wall (4). G Insert 2 5x45 screws (5) but do not tighten them completely, hang the hood (6). G Adjust the unit so that it is positioned at a right angle to the wall by turning the two screws on lower side (7). G Tighten the 2 upper screws (8). G From inside the hood, insert the third 5x45 screw into the lower hole (9) and tighten (10).                 

AEG Hausgeräte GmbH

Postfach 1036 D-90327 Nürnberg http://www.aeg.hausgeraete.de © Copyright by AEG LI1OSE Ed. 07/02